Flameproof Manual Call Points

Size: px
Start display at page:

Download "Flameproof Manual Call Points"

Transcription

1 Operating instructions Additional languages S & lifford & Snell Flameproof Manual all Points

2 ontents General Information.... Manufacturer.... Information regarding the operating instructions.... Further documents.... onformity with standards and regulations... Explanation of the symbols.... Symbols in these operating instructions.... Warning notes.... Symbols on the device... Safety notes.... Operating instructions storage.... Safe use.... Modifications and alterations... Function and device design.... Function...6 Technical data Transport and storage Mounting and installation Dimensions / fastening dimensions Mounting / dismounting, operating position Installation ommissioning Operation Troubleshooting Maintenance and repair Maintenance Repair Returning the device...9 leaning...0 Disposal...0 Accessories and Spare parts...0 Flameproof Manual all Points

3 General Information. Manufacturer R. STAHL Schaltgeräte GmbH Business Unit Lighting & Signalling Nordstr Weimar Germany Phone: Fax: Internet: . Information regarding the operating instructions ID-No.: 006 / MP Publication ode: 0-0- BA00 III en 00 The original instructions are the English edition. They are legally binding in all legal affairs.. Further documents Data sheet For documents in further languages, see onformity with standards and regulations See certificates and E Declaration of onformity: The device has IEEx approval. See IEEx homepage: Explanation of the symbols. Symbols in these operating instructions Symbol Meaning info@stahl.de R. STAHL Schaltgeräte GmbH Am Bahnhof Waldenburg Germany Phone: Fax: Internet: General Information info@stahl.de Tips and recommendations on the use of the device General danger Danger due to explosive atmosphere Danger due to energised parts 006 / MP BA00 III en 00 Flameproof Manual all Points

4 Explanation of the symbols. Warning notes Warnings must be observed under all circumstances, in order to minimize the risk due to construction and operation. The warning notes have the following structure: Signalling word: DANGER, WARNING, AUTION, NOTIE Type and source of danger/damage onsequences of danger Taking countermeasures to avoid the danger or damage. Symbols on the device DANGER Danger to persons Non-compliance with the instruction results in severe or fatal injuries to persons. WARNING Danger to persons Non-compliance with the instruction can result in severe or fatal injuries to persons. AUTION Danger to persons Non-compliance with the instruction can result in light injuries to persons. NOTIE Avoiding material damage Non-compliance with the instruction can result in material damage to the device and / or its environment. Symbol 09E00 Meaning E marking according to the current applicable directive. According to marking, device certified for hazardous areas. 098E00 Input 69E00 Output 68E00 Flameproof Manual all Points 006 / MP BA00 III en 00

5 Safety notes. Operating instructions storage Read the operating instructions carefully. Store the operating instructions at the mounting location of the device. Observe applicable documents and operating instructions of the devices to be connected. Safety notes. Safe use Read and observe the safety notes in these operating instructions! Observe characteristic values and rated operating conditions on the rating and data plates! Observe additional information plates on the device! Use the device in accordance with its intended and approved purpose only! We cannot be held liable for damage caused by incorrect or unauthorized use or by non-compliance with these operating instructions. Before installation and commissioning, make sure that the device is not damaged! Work on the device (installation, maintenance, overhaul, repair) may only be carried out by appropriately authorized and trained personnel.. Modifications and alterations DANGER Explosion hazard due to modifications and alterations to the device! Non-compliance results in severe or fatal injuries. Do not modify or alter the device. No liability or warranty for damage resulting from modifications and alterations. Function and device design DANGER Explosion hazard due to improper use! Non-compliance results in severe or fatal injuries. Use the device only in accordance with the operating conditions described in these operating instructions. Use the device only for the intended purpose specified in these operating instructions. 006 / MP BA00 III en 00 Flameproof Manual all Points

6 Technical data. Function Application range The MP/PB is a double action safety switch. The device is certified for use in hazardous areas of Zones and (gas) and and (dust). The device is suitable for gas group II and dust group III. It can also be used in harsh environments. Mode of operation The switch is protected by a cover. It is activated via a pushbutton and reset using the supplied tool. The device can be supplied with a number of options and accessories. Technical data Explosion Protection Global (IEEx) Gas and dust IEEx BAS X IE : 0 / IE : / IE : 008 Ex d II T6 Ta - to +70 Gb Ex tb III T8 Ta - to +70 Db IP66 Europe (ATEX) Gas and dust Baseefa 08ATEX069X : 009 / : 007 / : 009 E II G Ex d II T6 Ta - to +70 Gb E II D Ex tb III T8 Ta - to +70 Db IP66 ertifications and certificates ertificates IEEx, ATEX, Brazil (INMETRO), India (PESO) Technical Data Electrical data Rated operational voltage Switching capacity to 0 V D, to 0 V A D to 0 V A 0 to 0 V A A to 0 V A ontact element Switch System test Ambient conditions Operating temperature range standard: change-over contact optional: change-over contacts NO or N Test key provided -0 to Flameproof Manual all Points 006 / MP BA00 III en 00

7 Transport and storage Technical Data Mechanical data Material Enclosure material glass fibre reinforced polyester (GRP) Surface finish two pack, acrylic polyurethane, various colour options Degree of protection IP66 acc. to IE 609 able entries cable entries, supplied with (x) Ex d stopping plugs and (x) dust cap Position of cable entries onnection Terminals 7 way terminal block., mm Earth connection Accessories LED status indication Lift flap Duty label Tag label Resistors Mounting / Installation Assembly Break glass call point provided as standard optional: red LED status indication(up to V D) stainless steel (break glass version only) Metalised polyester, customer to specify wording / symbols (see main picture for example) Stainless steel tag with polyester label, customer to specify max 9 characters ustomer to specify value via holes through the back box. see operating instruction for full details 9E00 6E00 9E00 Break glass call point with lift flap Push button call point For further technical data, see 6 Transport and storage Transport and store the device only in the original packaging. Store the device in a dry place (no condensation) and vibration-free. Do not drop the device. 006 / MP BA00 III en 00 Flameproof Manual all Points 7

8 Mounting and installation 7 Mounting and installation The device is approved for use in gas explosion hazardous areas of Zones and and dust explosion hazardous area of Zones and and in safe areas. DANGER Explosion hazard due to incorrect installation of the device! Non-compliance results in severe or fatal injuries. arry out installation strictly according to the instructions and national safety and accident prevention regulations to maintain the explosion protection. Select and install the electrical device so that explosion protection is not affected due to external influences, i.e. pressure conditions, chemical, mechanical, thermal and electric impact such as vibration, humidity and corrosion (see IE/ ). The device must only be installed by trained qualified personnel who is familiar with the relevant standards. 7. Dimensions / fastening dimensions Dimensional drawings (all dimensions in mm [inches]) subject to alterations MP/PB,0 [,],0 [,] 7 [,9] 98 [, 86] 9 [,] Ø,0 [Ø 0,] 07,0 ± 0, [, ± 0,00] 78 [,07] [,07 ± 0,00] 7, ± 0,, ± 0, [0, ± 0,00] 9E00 7. Mounting / dismounting, operating position DANGER Explosion hazard due to improper mounting! Non-compliance can result in severe or fatal injuries. Only mount the device on walls or a suitable surface. Fit the core sleeves gas-tight and only using a suitable tool. arefully remove or replace the components. arefully protect exposed joint surfaces from damage, dust and dirt. Install end flange without applying force (without hammer and tool) in straight alignment. 8 Flameproof Manual all Points 006 / MP BA00 III en 00

9 7. Installation Mounting and installation DANGER Explosion hazard due to open holes, unused cable entries and cable glands! Non-compliance can result in severe or fatal injuries. Only use approved and flameproof (Ex d) cable glands. When selecting cable entries, observe the thread type and thread size in the component documentation. Seal thread with non-hardening thread sealant. Always close unused holes, cable entries and cable glands using approved stopping plugs or plugs. Observe IE/ for this. AUTION Danger of electric shock due to energised parts! Non-compliance can result in minor injuries! All connections must be disconnected from the power supply. Secure the connections against unauthorized switching. orrect reassembly of the unit is required to ensure ingress protection to IP Preparation for electrical installation heese-head screws M x 6 MP front cover PB fixing screw PB MP base 679E00 Remove the cover A retaining strap is fitted between the base and front cover. Depending on the variant of MP which has been selected, the PB may or may not have to be removed during installation. Details about this can be found in the "Electrical connection" chapter. Remove cheese-head screws. arefully lift MP front cover. 006 / MP BA00 III en 00 Flameproof Manual all Points 9

10 Mounting and installation Replace the components and close the cover If necessary, replace PB and screws. Replace front cover without pinching the retaining strap. Tighten cheese-head screws with a torque of 6. Nm. 7.. Electrical onnection Key omponents 7.. ircuit diagrams 7.. Standard devices Single-pin MP, switch normally open in standby / normally closed in alarm LK TB LK TB LK LK ommon N/O N/ 6 680E00 able connection (from right) fixing points for PBs Breakable tabs for independent switch function Terminal block onnector for switch 6 LK, LK and LK connections for special variants MP switch can be operated normally open or normally closed to suit different systems. The device can be purchased with a single or two-pin switch. Two-pin switch can be used as standard or to switch independent circuits. An LED indication light is available as an optional extra. Standard wiring configurations are listed below. If further information is required please contact your local sales office. LK ommon N/O N/ able connection (from right) N / - L / + Make sure that the LK connection has been removed. Single pin MP, switch normally closed in standby / normally open in alarm 68E00 LK TB LK ommon N/O N/ able connection (from right) N / - L / + 68E00 Make sure that the LK connection has been removed. 0 Flameproof Manual all Points 006 / MP BA00 III en 00

11 Two-pin MP, switch normally open in standby / normally closed in alarm (independent circuits) Unscrew PB, lift it and break tabs. Make sure that the LK connection has been removed. Mounting and installation Two-pin MP, switch normally closed in standby / open in alarm (independent circuits) LK TB LK TB LK ommon N/O N/ LK ommon N/O N/ 68E00 68E00 Unscrew PB, lift it and break tabs. Make sure that the LK connection has been removed. 7.. Standard devices with monitoring resistors able connection (from right) N / - pin N / - pin L / + pin L / + pin able connection (from right) N / - pin N / - pin L / + pin L / + pin Standard variants with monitoring resistors are only available with switch normally closed in standby / normally open in alarm. Resistor values are to be selected by the system designer, depending on requirements. The PB is 0 ohms resistance. For V D systems, a minimum resistor value of 70 ohms should be used. Single pin MP, switch normally closed in standby / normally open in alarm R R Normal / Standby Switch closed End-of-line resistor active L / + N / E / MP BA00 III en 00 Flameproof Manual all Points

12 Mounting and installation 6 7 Make sure that the LK connection has been removed. In-line resistor between positions & 6 R. End-of-line resistor between positions & R Standard devices with LED status light R R Single-pin MP, switch normally open in standby / normally closed in alarm a a a a 7E00 Active / Alarm Switch open In-line resistor engaged L / + N / - There is an 80 ohm resistor which is in-line with the LED. When activated, the LED together with the resistor will draw a current. On a V D, system this current is approximately 0 ma. 767E00 Ensure that connector wires from switch and LED are correctly installed as per the diagram (see following figure). a a onnector block Red wire for LED Black wire for LED Yellow wire for switch Blue wire for switch Red wire for switch 768E00 LK TB LK Lk ommon N/O N/ able connection (from right) N / - L / + 78E00 Flameproof Manual all Points 006 / MP BA00 III en 00

13 Mounting and installation Remove LK for LED activation in alarm or remove LK for LED activation in standby. Jumper/connection between terminal and. Single pin MP, switch normally closed in standby / normally open in alarm a a a a 767E00 Ensure that connector wires from switch and LED are correctly installed as per the diagram (see following figure). a LK TB LK Lk ommon N/O N/ 768E00 79E00 Remove LK for LED activation in alarm or remove LK for LED activation in standby. Jumper/connection between terminal and. a onnector block Red wire for LED Black wire for LED Yellow wire for switch Blue wire for switch Red wire for switch able connection (from right) N / - L / + Two-pin MP, switch normally open in standby / normally closed in alarm (independent circuits) a a a a 767E00 Ensure that connector wires from switch and LED are correctly installed as per the diagram (see following figure). 006 / MP BA00 III en 00 Flameproof Manual all Points

14 Mounting and installation a a a a LK TB LK Lk ommon N/O N/ 770E00 70E00 Remove LK for LED activation in alarm or remove LK for LED activation in standby. Jumper/connection between terminal and. Two-pin MP, switch normally closed in standby / open in alarm (independent circuits) a a a a 767E00 Ensure that connector wires from switch and LED are correctly installed as per the diagram (see following figure). a a a a onnector block Red wire for LED Black wire for LED Yellow wire for switch Yellow wire for second switch Blue wire for switch Blue wire for second switch Red wire for switch Red wire for second switch able connection (from right) N / - N / - L / + L / + a a a a a a a a onnector block Red wire for LED Black wire for LED Yellow wire for switch Yellow wire for second switch Blue wire for switch Blue wire for second switch Red wire for switch Red wire for second switch 770E00 LK TB LK Lk ommon N/O N/ able connection (from right) N / - N / - L / + L / + 7E00 Flameproof Manual all Points 006 / MP BA00 III en 00

15 Mounting and installation Remove LK for LED activation in alarm or remove LK for LED activation in standby. Jumper/connection between terminal and Standard devices with monitoring resistors and LED status light Standard variants with monitoring are only available with switch normally closed in standby / normally open in alarm with LED activated. There is an 80 ohm resistor which is in-line with the LED. When activated, the LED together with the resistor will draw a current. On a V D system, this current is approximately 0 ma. In standby without the LED activated, the resistance of the the PB is 0 ohms. Resistor values are to be selected by the system designer, depending on requirements of the system. For V D systems, a minimum resistor value of 70 ohms should be used. Single pin MP, switch normally closed in standby / normally open in alarm a a a a 767E00 Ensure that connector wires from switch and LED are correctly installed as per the diagram (see following figure). a a a a onnector block Red wire for LED Black wire for LED Yellow wire for switch Blue wire for switch Red wire for switch Red wire for LED 769E00 R R Normal / Standby Switch closed end-of-line resistor engaged L / + N / E / MP BA00 III en 00 Flameproof Manual all Points

16 ommissioning Make sure that the LK connection has been removed. In-line resistor between positions & 6 R. End-of-line resistor between positions & R Earth connection 8 ommissioning 6 7 R R 77E00 Active / Alarm Switch open in-line resistor engaged L / + N / - DANGER Explosion hazard due to incorrect installation! Non-compliance results in severe or fatal injuries. heck the device for proper installation before commissioning. omply with national regulations. Before commissioning, ensure the following: heck the mounting and installation. Enclosure must not be damaged. If necessary, remove foreign bodies. If necessary, clean the connection chamber. heck if the conductors have been inserted correctly. heck if all screws and nuts have been tightened firmly. heck if all conductors have been clamped firmly. heck if all prescribed tightening torques have been observed. heck whether the bayonet lock is tightened firmly. Make sure that the plug pin surface is not damaged. Use only in completely mounted state. 680E00 6 Flameproof Manual all Points 006 / MP BA00 III en 00

17 9 Operation Test and reset procedure 68E00 68E00 68E00 Activate function: Open the cover. Press the pushbutton. The pushbutton engages and the contact is actuated. Reset manual signaling device: Put the key onto the button. Operation Rotate the key 90 to the left or right. 68E00 Remove the button. 68E / MP BA00 III en 00 Flameproof Manual all Points 7

18 Maintenance and repair 9. Troubleshooting If the error cannot be eliminated using the mentioned procedures: ontact R. STAHL Schaltgeräte GmbH. For fast processing, have the following information ready: Type and serial number of the device Purchase information Error description Intended use (in particular input / output wiring) 0 Maintenance and repair 0. Maintenance AUTION Risk of electric shock or malfunction of the device due to unauthorized work! Non-compliance can result in light injuries! Before carrying out work on the device, switch off voltage supply. Work performed on the device must only be carried out by authorized and appropriately trained qualified electricians. Observe the relevant national regulations in the country of use. Determine the type and extent of inspections in compliance with the relevant national regulations. Adapt inspection intervals to the operating conditions. The following tests and measures must be carried out during regular maintenance. heck the permissible ambient temperature the enclosure components for formation of cracks and damage. its intended use Measures If exceeding the permissible ambient temperature or falling below the device must be taken out of operation. Replace the exchangeable enclosure components. If the enclosure components are non-exchangeable, the device must be taken out of operation. If the device is not used according to its intended use, it must be taken out of operation. if the conductors are clamped properly the cables for ageing and damage the seals for ageing and damage clamp loose conductors tightly. replace damaged or aged cables. replace damaged, aged and porous seals and completely change enclosure components with foamed seal. 8 Flameproof Manual all Points 006 / MP BA00 III en 00

19 0. Repair DANGER Explosion hazard due to improper repair! Non-compliance results in severe or fatal injuries. Repair work on the devices must be performed only by R. STAHL Schaltgeräte GmbH. 0. Returning the device Use the "Service form" to return the device if repair or service is required. On the internet site " under "Downloads > ustomer service": Download the service form. Fill out the service form. Send the device along with the service form in the original packaging to R. STAHL Schaltgeräte GmbH. leaning leaning lean the device only with a cloth, brush, vacuum cleaner or similar items. When cleaning with a damp cloth, use water or mild, non-abrasive, non-scratching cleaning agents. Do not use aggressive detergents or solvents. Disposal Observe national and local regulations and statutory regulation regarding disposal. Separate materials when sending it for recycling. Ensure environmentally friendly disposal of all components according to the statutory regulations. Accessories and Spare parts NOTE Malfunction or damage to the device due to the use of non-original components. Non-compliance can result in material damage. Use only original accessories and spare parts from R. STAHL Schaltgeräte GmbH. For accessories and spare parts, see data sheet on our homepage / MP BA00 III en 00 Flameproof Manual all Points 9

20

Operating Instructions

Operating Instructions Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4

More information

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex

More information

Operating Instructions

Operating Instructions Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

Flameproof Audible Signal 115 db (A) Series YA90

Flameproof Audible Signal 115 db (A) Series YA90 Clifford Snell www.stahl.de > Max sound output 115 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > 32 selectable tones meeting international regulations > Light

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

Operating Instructions

Operating Instructions Operating Instructions Control unit Ex p > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage

More information

Control Stations Made of Polyester Resin Series 8146

Control Stations Made of Polyester Resin Series 8146 ontrol Stations Made of Polyester Resin www.stahl.de > s made of glass-fibre reinforced polyester resin > 8 basic enclosure sizes with various enclosure heights > an be combined to larger units > Equipped

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

Technical data sheet TDS0070

Technical data sheet TDS0070 Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier

More information

Control Stations in Sheet steel or Stainless Steel Series 8125

Control Stations in Sheet steel or Stainless Steel Series 8125 ontrol Stations in Sheet steel or Stainless Steel www.stahl.de > in electropolished stainless steel 1.4404 (ISI 316L) or zinc-galvanised sheet steel painted > 6 basic enclosure sizes with different enclosure

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP) Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal

More information

Control and Distribution Boxes made of Stainless Steel Series 8150

Control and Distribution Boxes made of Stainless Steel Series 8150 www.stahl.de > Circumferential protection channel prevents water entry > Extended temperature range due to high-quality seal s > Optionally with hinges / cam locks or screw-on cover > Hinge versions with

More information

Infrarot-Bewegungsmelder IP44

Infrarot-Bewegungsmelder IP44 Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Operating Instructions Electronics module VEGADIF 65

Operating Instructions Electronics module VEGADIF 65 Operating Instructions Electronics module VEGADIF 65 Document ID: 36132 Differential pressure Contents Contents 1 About this document 1.1 Function.................................. 3 1.2 Target group..............................

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, Flameproof Enclosure Series 8264. www.stahl. > Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The

More information

Instructions for Safe Use

Instructions for Safe Use Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety

More information

Explosion Proof Combination Signal - 110 db (A) / 5 Joule Series YL60

Explosion Proof Combination Signal - 110 db (A) / 5 Joule Series YL60 www.stahl.de Explosion Proof Combination Signal - 110 db (A) / 5 Joule > Omnidirectional high output sounder 110 db (A) / 1 m > 5 Joule xenon strobe > 2 stage alarm, independently selectable 2nd stage

More information

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall

More information

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 REMOTE METER TM Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 1098 Washington Crossing Road Washington Crossing, PA 18977 USA www.morningstarcorp.com

More information

Antenna Splitter ASA 1. Instruction manual

Antenna Splitter ASA 1. Instruction manual Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...

More information

Elektromotoren und Gerätebau Barleben GmbH

Elektromotoren und Gerätebau Barleben GmbH Elektromotoren und Gerätebau Barleben GmbH OPERATING INSTRUCTIONS Transformer Protection Relay NM Series (Buchholz principle) Elektromotoren und Gerätebau Barleben GmbH Table of contents Page 1. Safety

More information

Wolflite Safety Handlamp H-251E

Wolflite Safety Handlamp H-251E Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Wolflite Safety Handlamp H-251E H 18Y H 17 H 31Y H 21A H 30 H 24 H 26 H 19 H 25 H 03 H 15Y H 22 H 104 H 29 H 66 H 13 H 14 H 09 H 12 H 48 H 11 H 62 H 63

More information

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

15GAL STEEL OIL DRAIN WITH 110V PUMP

15GAL STEEL OIL DRAIN WITH 110V PUMP 15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

Installation and safety instructions for AC/DC built-in devices

Installation and safety instructions for AC/DC built-in devices The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further

More information

Ambient Temperature Sensor TEMPSENSOR-AMBIENT

Ambient Temperature Sensor TEMPSENSOR-AMBIENT Ambient Temperature Sensor TEMPSENSOR-AMBIENT Installation Guide TempsensorAmb-IEN110610 98-0042210 Version 1.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this Guide...............................

More information

Acclaim III Recessed Fluorescent Luminaires ATEX

Acclaim III Recessed Fluorescent Luminaires ATEX Acclaim III Recessed Fluorescent Luminaires ATEX INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment.

More information

98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC.

98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC. 81471067 Electric Monitor Motor Control Panel For use with Model 8394059 SPIT-FIRE Monitor Installation, Operation, and Maintenance Instructions FOR ATEX APPLICATIONS 1302 WEST BEARDSLEY AVENUE P.O. BOX

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) Please read these instructions thoroughly before installation and ensure they are passed

More information

Instruction Manual Differential Pressure Transmitter

Instruction Manual Differential Pressure Transmitter DE28 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

Mounting instructions. Junction box VKK2R-8 DIGITAL. A1145-1.0 en

Mounting instructions. Junction box VKK2R-8 DIGITAL. A1145-1.0 en Mounting instructions Junction box VKK2R-8 DIGITAL VKK2R-8 DIGITAL 3 Contents Page Safety instructions... 4 1 Introduction and appropriate use... 7 2 Mechanical construction... 8 2.1 Mounting... 9 3 Electrical

More information

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Contents 1 Preliminary note 3 1.1 Symbols used 3 1.2 Warning signs used 3 2 Safety instructions

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119 EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70

More information

Givare NC-SRS 280 och 880

Givare NC-SRS 280 och 880 Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness

More information

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) OPERATION MANUAL (Ceiling mounted duct type) VAM50FB VAM500FB VAM650FB VAM800FB VAM000FB VAM500FB VAM000FB 8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6 7 A A B B 5 6 5 6 7 VAM50F VAM800F VAM500F VAM500F VAM000F

More information

HAIR CLIPPER. Model No. HC5150 HC5150 2. 3.

HAIR CLIPPER. Model No. HC5150 HC5150 2. 3. All technical modifications reserved. 09/08. TSC 08.0634 HAIR CLIPPER 2. 3. 1. Model No. HC5150 4. 10/UK/HC5150 Version 03/10 Part No. T22-29458 REMINGTON is a Registered Trade Mark of Spectrum Brands,

More information

Operating Instructions Bedienungsanleitung Mode d emploi

Operating Instructions Bedienungsanleitung Mode d emploi Operating Instructions Bedienungsanleitung Mode d emploi DW 400 www.bron-kobold.com Operating instructions DW 400 Before use Please read all the information contained in these operating instructions carefully.

More information

19 LED Tube Controller ORDERCODE 41003

19 LED Tube Controller ORDERCODE 41003 19 LED Tube Controller ORDERCODE 41003 Congratulations! You have bought a great, innovative product from Showtec. The Showtec 19 LED Tube Controller brings excitement to any venue. Whether you want simple

More information

3M Wrist Strap and Footwear Tester 740. User s Guide

3M Wrist Strap and Footwear Tester 740. User s Guide 3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6

More information

Compact pressure switch Flameproof enclosure Ex d Model PCA

Compact pressure switch Flameproof enclosure Ex d Model PCA Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring

More information

Digital Fingerprint safe

Digital Fingerprint safe Digital Fingerprint safe Model 96846 Operation Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors D7050/D7050TH EN Installation Instructions Multiplex Photoelectric Smoke Detectors D7050/D7050TH Installation Instructions.0 Description Notices These instructions cover the installation of the D7050/D7050TH

More information

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions SBC90 Abrasive Blast Cabinet Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This manual provides important

More information

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004 Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Addendum to the Operating Instructions

Addendum to the Operating Instructions Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A

More information

MIC-WKT and MIC-WKT-IR

MIC-WKT and MIC-WKT-IR MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems EN Installation and Operation Manual MIC-WKTI and MIC-WKT-IR Installation Manual EN 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits

More information

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction Manual Supplement Rosemount 5300 and 5400 Series Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction Introduction..................................... page S-1 Safety Messages.................................

More information

Single Station Remote Alarm

Single Station Remote Alarm ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation

More information

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual. i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580

Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580 Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor

More information

Switches and Indicators. Swisstac

Switches and Indicators. Swisstac Switches and Indicators Switches and Indicators Index Series Description Page 583 Product Assembly Page 584 Mounting Instruction Page 585 Product Range - pushbuttons for standard mounting - pushbuttons

More information

LUCCI AIRFUSION QUEST II CEILING FAN

LUCCI AIRFUSION QUEST II CEILING FAN LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR

More information

4.3-inch Back-Up Camera

4.3-inch Back-Up Camera TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION

More information

Manual. Solar Fountain Mobile Phone Charger

Manual. Solar Fountain Mobile Phone Charger EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.

More information

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing. www.hunterfan.com Table of Contents What to Expect with Your Installation 30 inches Hanging the Fan Wiring 8 Maintenance, Operation & Cleaning Light Kit 13??? 14 1 9 Troubleshooting 11 5 Blades Motor Housing

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

KeContact P20 User manual

KeContact P20 User manual KeContact P20 User manual General notes for this manual At various points in this manual you will see notes and precautionary warnings regarding possible hazards. The symbols used have the following meanings:!!!

More information

BroadBand PowerShield. User Manual

BroadBand PowerShield. User Manual BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains

More information

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop

More information

StorTrends 3400 Hardware Guide for Onsite Support

StorTrends 3400 Hardware Guide for Onsite Support StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200

More information

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide VOT-320 VOT-320V0xxL VOT-320V0xxH en Quick Installation Guide VOT-320 Table of Contents en 3 Table of Contents 1 General information 4 2 Parts included 5 3 Unpacking 6 4 Installing and connecting 7 4.1

More information

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN BeoLab 7-6 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified

More information

Sunny Boy Accessories SMA POWER BALANCER

Sunny Boy Accessories SMA POWER BALANCER Sunny Boy Accessories SMA POWER BALANCER Installation Guide SBUS-PowBal-IUS102810 IMUS-SBUS-PBL Version 1.0 US SMA America, LLC Legal Restrictions Copyright 2010 SMA America, LLC. All rights reserved.

More information

Load Limiter ULS-60 ULS-80 ULS-100 ULS-125. Table of Contents. Assembly Instructions Load Limiter ULS-60, -80, -100, -125

Load Limiter ULS-60 ULS-80 ULS-100 ULS-125. Table of Contents. Assembly Instructions Load Limiter ULS-60, -80, -100, -125 Load Limiter ULS-60 ULS-80 ULS-100 ULS-125 Version 2.0 Last revision November 2012 Dear customer, Thank you for the confidence that you have placed in our company by purchasing an IPR load limiter. Every

More information

SEISMIC VELOCITY TRANSDUCER T1-40

SEISMIC VELOCITY TRANSDUCER T1-40 SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute

More information

12 Volt 30 Amp Digital Solar Charge Controller

12 Volt 30 Amp Digital Solar Charge Controller 12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

3 740 Wrist strap + shoe tester

3 740 Wrist strap + shoe tester 3 740 Wrist strap + shoe tester Operating Instructions April, 2001 740 wrist strap + shoe tester 3 < o.k. > 1 2 1 / 11 LED for «too w resistance» 740 wrist strap + shoe tester 3 < o.k. > 1 2 LED for «too

More information

OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle

OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle OWNER S MANUAL US Permolock C3 Docking system for Power wheelchair in vehicle How to contact Permobil Head Office of the Permobil group Permolock C3 Docking system for electric wheelchair in vehicle Produced

More information

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering

More information

Floodlight Range Installation Guide

Floodlight Range Installation Guide SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected

More information

Achat 115MA full-range speaker. user manual

Achat 115MA full-range speaker. user manual Achat 115MA full-range speaker user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

Manual Ranging MultiMeter

Manual Ranging MultiMeter Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!

More information

Mini-led spotlight with magnetic base

Mini-led spotlight with magnetic base Mini-led spotlight with magnetic base Model 95799 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission

More information

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13 CONTROL PANEL INSTALLATION INSTRUCTIONS Single Phase Simplex Page 2-7 3-Phase Simplex Page 8-13 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED

More information

How To Use A Cdm250 Digital Multimeter

How To Use A Cdm250 Digital Multimeter User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this

More information

3/4 PIPE CLAMP WITH STAND

3/4 PIPE CLAMP WITH STAND 3/4 PIPE CLAMP WITH STAND Model 94053 ASSEMBLY AND OPERATING INSTRUCTIONS (3/4 DIAMETER PIPE NOT INCLUDED.) 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at: http://www.harborfreight.com

More information

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases

More information

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION: Revision Level: 01 Revision Date: 07/07/2011 Please read all instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Air Purifier. Failure to do

More information