Innovative Ultrafiltration (UF) Membrane for Produced Water Treatment

Size: px
Start display at page:

Download "Innovative Ultrafiltration (UF) Membrane for Produced Water Treatment"

Transcription

1 Innovative Ultrafiltration (UF) Membrane for Produced Water Treatment Authors: Lyndsey Wiles 1, Elke Peirtsegaele 1, Mike Snodgrass 1 1 TriSep Corporation, 93 South La Patera, Goleta CA Abstract Current unconventional oil & gas exploration methods both consume and generate large volumes of water that require proper treatment, handling, and management. This practice, combined with an increasing amount of water scarcity, has made water reuse a necessary focus for the oil & gas industry. As a result, oil & gas producers are seeking treatment options to use their water more effectively. Advanced treatment and reuse of produced and flowback water often requires ultrafiltration (UF), which removes suspended solids, bacteria and other microorganisms, as well as oil & grease. Traditionally, produced and flowback water has proven challenging for UF membranes due to its aggressive fouling tendencies. This paper examines three produced water case studies using an innovative UF membrane that was successfully operated with the following upstream treatment technologies: 1) coalescer, 2) walnut shell filter, and 3) electric coagulation. Despite differences in produced water quality at each test site, the UF membrane process was able to provide consistent effluent quality at a high throughput rate. Oil levels in the UF feed, regardless of upstream treatment, reached as high as 300 mg/l while suspended solids were consistently >50 mg/l. Undeterred by spikes in incoming water quality, the UF membrane provided consistent effluent quality: <1.0 mg/l oil & grease, <1.0 mg/l TSS, and <2.0 silt density index (SDI). Introduction As unconventional oil & gas production becomes increasingly prevalent, the amount of water produced via these methods will continue to grow. In the United States, produced water estimates are on the order of 20 billion barrels per year and are steadily rising (Clark and Veil, 2009). To account for ever-increasing fresh water scarcity throughout the country, oil & gas producers have realized that water must be utilized more effectively to ensure continued growth and development. Such concerns over water have pushed water reuse to the forefront of oil & gas exploration. High concentrations of various contaminants make produced water particularly challenging to treat through traditional methods. Produced water typically has oil levels in the range of mg/l (Clark and Veil, 2009), total suspended solids (TSS) in the range of mg/l (Guerra et al., 2011), total dissolved solids (TDS) in the range of 1, ,000 mg/l (Clark and Veil, 2009), and no bacteria present (Veil et al., 2004). Additionally, every oil & gas well has unique and often-changing water characteristics.

2 This presents a significant challenge to oil producers when determining the best treatment approach, and requires their collaboration with water industry experts in developing innovative treatment solutions. Successful produced water treatment technologies for reuse are those that can adapt to changing water quality while providing a reliable effluent stream. The size-exclusion mechanism of removing oil, suspended solids, and bacteria from a produced water stream via ultrafiltration (UF) offers an attractive method for the production of a consistent effluent stream. However, produced and flowback water have traditionally proven a challenge for UF membranes due to their aggressive fouling tendencies. Polymers used to manufacture ultrafiltration membranes are derived from oil and, historically, have been both highly oleophilic and hydrophobic. Such properties have left polymeric UF membranes vulnerable to severe and rapid fouling in applications like produced and flowback water treatment. This paper discusses an innovative UF membrane with a significantly greater oil tolerance than traditional UF membranes. This membrane has a proprietary hydrophilic polyvinylidene fluoride (PVDF) chemistry with a 0.03 micron pore size. The configuration of the discussed membrane is in a spiral-wound, submerged-style (vacuumoperated), module with air-scouring and backwashing capabilities, as shown in Figure 1. This membrane was developed for a variety of wastewater applications, and typically treats streams with about 1,000 mg/l TSS and has successfully treated streams with as high as 3,000 mg/l TSS. Due to its unique chemistry and its ability to handle tough feeds, this membrane was considered a strong candidate in exploring oily feeds. Figure 1: UF configuration isep 500-PVDF

3 The performance of the UF membrane was characterized by operating the same pilot unit system at three different test sites. This pilot unit allows for the membrane to be cleaned chemically or mechanically, utilizing backwashing or air scouring. Key components of this pilot unit include a permeate (vacuum) pump, backwash pump, chemical metering pumps, blower, automated valves, and other instrumentation. The pilot unit contains a touchscreen HMI for control and automation, and all process sequences, including production, backwash, and chemically-enhanced backwash. A process flow diagram of the pilot unit is shown in Figure 2. Automated Pump Control FI Flow Meter T Temperature Sensor Permeate Collection Tank FI P Pressure Gauge Automated Flow Meter Pump Drain isep Module Overflow Metering Pump Chlorine Drain Automated Metering Pump Caustic FI Feed Flow Meter Control Automated Acid Metering Pump FI Flow Meter Control Blower Figure 2: UF pilot unit process flow diagram Based on numerous lab scale studies demonstrating exceptional oil tolerance, the UF membrane was selected for a variety of pilots exploring the advanced treatment of produced water. When following initial oil-removal technologies, the UF membrane offers an advanced water treatment method for oil & gas producers to reuse their water. Three case studies involving a different upstream technology followed by the aforementioned UF membrane are examined. The different upstream treatment technologies for each case study are as follows: 1) coalescer, 2) walnut shell filter, and 3) electrocoagulation. Air

4 Case Study 1: Coalescer Upstream of UF As a result of the UF membrane s potential to tolerate high oil concentrations compared to traditional UF membranes, the membrane was selected for a pilot study on evaluating various technologies for advanced treatment of produced water. Piloting was conducted over the span of two weeks during August 2013 by an independent research organization in partnership with the various technology suppliers selected for the study. The short time frame involved was intended to demonstrate proof-of-concept for the technologies ability, to handle the challenges of produced water treatment. The feed water for this piloting was taken from an oil production site in the Midwest and was treated by a coalescer unit prior to being fed to the various technologies being evaluated, including the UF. Following pretreatment by the coalescer, the feed to the UF contained an average oil concentration of 22 mg/l, with a maximum of 45 mg/l, and an average turbidity of 160 NTU, with a maximum of 220 NTU, as displayed in Table 1. Table 1: Feed water characteristics with coalescer pretreatment Parameter Unit Value Average Turbidity NTU 160 Maximum Turbidity NTU 220 Average Oil Concentration mg/l 22 Maximum Oil Concentration mg/l 45 Throughout this trial, the UF operated on the feed described above without experiencing any of the serious issues commonly observed when using traditional UF membranes to treat oily feeds. Typically, oil fouling of a membrane results in a high transmembrane pressure (TMP) due to oil adhering to the membrane surface and restricting flow. Despite the presence of both oil and solids, the pilot unit maintained a reasonable TMP between 1-4 psi while providing high-quality effluent, as seen in Figure 3, demonstrating significant oil tolerance and removal.

5 Figure 3: UF feed (left) and permeate (right) demonstrating oil removal Further evidence of considerable oil removal was displayed by the UF. There were two different types of oil detection instruments deployed during this study: a fluorometer and an optical imaging device. When the UF permeate was examined by both of these devices, the oil concentrations were found to be below each instrument s detection limit, indicating oil levels <1 mg/l. These results for oil level detection confirm the oil removal capabilities of the membrane. Overall, the combination of oil tolerance and oil removal qualified this as a successful initial produced water pilot for the UF. During the testing, a variety of other technologies were subjected to the same feed water that was fed to the UF, including hollow fiber membranes and different forms of media filtration. Several of these technologies simply could not continue operating due to issues such as oil fouling. The fact that the UF was able to run for the entire two weeks without a serious fouling event showcases its ability to tolerate the oily streams of produced water.

6 Case Study 2: Walnut Shell Filter Upstream of UF After a successful proof-of-concept study in the Midwest, the UF was selected for another piloting opportunity at a produced water treatment research facility to take place in early The piloting was carried out by a company in the United States that wanted to evaluate various membrane technologies for produced water applications. Testing was done over the span of a month, offering more time to analyze the membrane performance. To maintain consistency throughout the entirety of testing, a synthetic produced water was used as the feed to the overall treatment process. After mixing of the synthetic produced water, the stream was fed to a walnut shell filter (WSF) for bulk oil removal. Following the WSF, the filtered stream was fed to the UF, followed by a reverse osmosis (RO) unit. To accurately duplicate a produced water stream, various constituents were added to obtain desired levels of oil, TSS, TDS, and several organic compounds, as shown in Table 2. After addition of the oil to the synthetic waste stream, the oil and other hydrocarbons were mechanically emulsified. Table 2: Synthetic produced water composition Chemical Compound Concentration (mg/l) Ca 250 Fe 10 Mg 75 K 200 Na 1,700 SO4 100 CO3 (as CaCO3) 500 Cl 3,015 TSS (majority as bentonite) 20 Oil 30 Benzene 2 Toluene 0.5 Ethylbenzene 0.5 Xylenes 0.5 Upon pilot start-up, the feed water quality to the UF was mild, with oil levels <10 mg/l and turbidity levels well below 1.0 NTU. As a result, very low TMPs were observed during this time, indicating extremely efficient membrane performance. Based off this performance, an operating flux of 30 gfd was chosen for the remainder of the pilot study. As planned, the oil concentration from the WSF increased and fluctuated, with an average concentration of 34.8 mg/l and a maximum concentration of 166 mg/l. Despite the significant spikes in oil concentrations, as shown by the presence of oil on top of the module (see Figure 4), the UF continued to perform well. To understand the maximum oil tolerance of the UF, it was decided to bypass the WSF altogether. Bypassing the WSF resulted in an average UF feed oil concentration of 72 mg/l with a maximum concentration of 288 mg/l.

7 Figure 4: Visual presence of high oil levels in UF feed During the third week of testing a fouling event occurred, as shown by a significant TMP spike from 3.7 to 10.7 psi in the span of a single day. Initially thought to be due to the significant oil concentrations being fed to the UF, it was later found that an unexpected algaecide containing a cationic surfactant contributed considerably to the membrane fouling. To restore UF performance, membrane cleanings were attempted with chlorine, caustic, acid, and a detergent alkaline cleaner. The detergent alkaline cleaner successfully restored the TMP to its original start-up levels. Since membrane cleanings are a common part of membrane operation and maintenance, the TMP restoration by cleaning is a valuable demonstration of this membrane s ability to operate successfully in this application. Similarly to the pilot study with the coalescer, this pilot study demonstrates the membrane s ability to maintain permeability (i.e. performance), despite fluctuating oil levels with relatively large spikes. Extended operation at moderate to high oil levels indicate the hydrophilic PVDF membrane has significant oleophobic properties. Graph 1 shows TMP, flux, and temperature-corrected membrane permeability during the pilot study. Since permeability decreases as membrane fouling increases, the relatively stable permeability and restoration of permeability after cleaning attest to the membrane s resistance to oil fouling.

8 Graph 1: TMP, flux, and permeability of the UF over time TMP (psi) Flux (gfd) Permeability (gfd/psi) Hours of Operation Oil removal capabilities were further demonstrated and quantified by this testing as well. Throughout the month of piloting, the average oil concentration fed to the UF was 53.4 mg/l. Even with the spikes in oil, the UF consistently provided effluent oil concentrations of <1 mg/l, as shown in Graph 2 below. As with the intial pilot, oil detection methods were not always accurate, but it was mutually agreed that the UF permeate had <1 mg/l oil because the RO unit running on UF permeate did not experience significant fouling issues. The UF consistently provided permeate suitable for RO feed, as demonstrated by measuring silt density index (SDI), a common feed water qualifying method in RO systems. Typically, a feed SDI of 3.0 is a common design criterion for RO systems. The UF membrane consistently produced permeate with SDI values well below 2.0, indicating very high effluent quality.

9 Graph 2: Influent and effluent water quality of the UF Feed Oil (mg/l) Feed Turbidity (NTU) 1 Permeate Oil (mg/l) Permeate Turbidity (NTU) Hours of Operation Overall, this pilot study gave additional evidence for the UF s oil tolerance and removal capabilities. A summary of the pilot study results is given in Table 3. Based on this successful pilot opportunity, additional opportunities were sought out and secured, resulting in the third case study. Table 3: Summary of UF performance Parameter Units Value Operating Flux gfd TMP (average) psi 2.85 Temperature C Influent Turbidity NTU Effluent Turbidity NTU Effluent SDI Influent Oil mg/l Effluent Oil mg/l Backwash Frequency min 15 Backwash Duration sec 60 Relaxation Duration sec 60

10 Case Study 3: Electrocoagulation Upstream of UF With about 1 of every 50 barrels of U.S. oil output coming from Colorado, its Western Slope region has become an important location for exploring produced water treatment options (U.S. EIA 2014). In mid-2014, this fact, combined with a better understanding of what the UF could handle, led to a third piloting opportunity. Piloting began in May 2014, and the raw feed water source was a producing oil well in the Western Slope. In this case, the technology utilized for bulk oil removal ahead of the UF was a multi-step electrocoagulation process. The overall goal of this pilot was to demonstrate the potential of using the electrocoagulation process followed by the UF for reuse applications, such as RO, direct reuse, or surface discharge. To accomplish this demonstration, the pilot was run for two weeks and water samples from various stages of the process were taken for analysis. The UF worked well with the electrocoagulation process and produced water that visually accomplished the treatment goals. Samples of water were taken at various stages of the electrocoagulation process and UF, and a picture of them is displayed in Figure 5. The clear water produced by the UF indicated satisfactory operation by the UF. Figure 5: UF feed (second to right) and permeate (furthest right) demonstrating satisfactory oil removal In accordance with the first two piloting experiences, the UF demonstrated promising oil tolerance and removal. Throughout testing, the UF maintained a relatively constant permeability and TMP. Shortly after 20 hours of operation, the TMP spiked and the

11 permeability sharply decreased due to a treatment issue prior to the UF. Upon resuming normal operation of the UF, TMP and permeability were restored to a stable level, demonstrating the UF s capability of handling stream upsets, as shown in Graph 3. Graph 3: TMP and permeability over time TMP (psi) Permeability (gfd/psi) Hours of Operation Similarly to the initial piloting experience, exact oil concentration in the UF permeate was difficult to measure. Samples were taken for analysis, and it was found that the UF provided a permeate oil concentration of <1.0 mg/l, despite a significant solids loading. Since each well can have different water quality, the UF s ability to handle both high solids and high oil concentrations is a good indication of its flexibility to tolerate a wide variety of produced waters. A summary of the water quality characteristics is provided in Table 4. Table 4: Influent and effluent water quality of the UF Parameter Units Value Influent Turbidity NTU 76.2 Effluent Turbidity NTU 0.02 Influent Oil Concentration mg/l ~20 Effluent Oil Concentration mg/l <1.0 mg/l After optimizing pilot operation, another valuable analysis was performed during this testing: an operating cost analysis. To determine total power consumption, the power usage of the permeate, backwash, and metering pumps was recorded. Based off these values, the total power consumption at this pilot was found to be kw per bbl. To determine the overall operating cost, cleaning chemical, membrane replacement, and power costs were taken into account. Combining these factors together revealed that

12 operating costs would be <$0.01 per bbl, thus characterizing the UF as an affordable method of advanced treatment for produced water. In conjunction with the oil tolerance and oil removal capabilities further demonstrated by this pilot, the low operating costs prove that the UF offers a valuable treatment option of produced water. Conclusion The three case studies show that the described UF provides an effective option for the advanced treatment of produced water following initial bulk oil removal technologies. Based off the piloting results discussed in this paper, the UF can tolerate up to 300 mg/l oil, demonstrating significant oil tolerance over traditional polymeric UF membranes. In addition, the piloting results show that the UF provides permeate with <1 mg/l oil, highlighting its oil removal capabilities. Along with its solids removal capabilities, the UF consistently provides SDIs below 2.0, well below the usual design specification of 3.0 for RO feed water quality. UF membranes capable of handling high levels of oil and suspended solids have become an attractive treatment option for oil producers. The ability to tolerate and remove high levels of oils greatly simplifies produced and flowback water treatment by consolidating multiple treatment steps into one. Reduction in treatment scope drives down both capital and operating costs, making advanced water reuse much more attractive to the oil industry. Since UF is a distinct barrier layer that removes oil, it also provides oil producers the opportunity to capture additional oil by processing of the UF retentate. Additional oil recovery allows UF membranes to serve as not just a wastewater treatment step, but a revenue-generating step as well. As a new and challenging source of water, produced water creates a unique challenge for oil producers that necessitates innovative treatment schemes. Flexible options such as this UF will play a vital role in turning produced water into a valuable source of water rather than a source of environmental concern for the general public. Fracking and other unconventional oil exploration methods will be a necessity if the United States wishes to reduce its dependence on foreign oil, and those involved in water treatment should rise to this challenge by developing effective and affordable treatment options.

13 Sources Clark, C.E. and Veil, J.A. Produced Water Volumes and Management Practices in the United States. Environmental Science Division, Argonne National Laboratory. September Guerra, K., Dahm, K., and Dundorf, S. Oil and Gas Produced Water Management and Beneficial Use in the Western United States. U.S. Department of the Interior. September Veil, J.A., Puder, M. G., Elcock, D., and Redweik, Jr., R.J. A White Paper Describing Produced Water from Production of Crude Oil, Natural Gas, and Coal Bed Methane. Argonne National Laboratory. January Colorado State Energy Profile. U.S. Energy Information Administration. August 2014.

DOW Ultrafiltration. Case History. High Turbidity and Temperature Fluctuation No Obstacle for DOW Ultrafiltration

DOW Ultrafiltration. Case History. High Turbidity and Temperature Fluctuation No Obstacle for DOW Ultrafiltration Case History High Turbidity and Temperature Fluctuation No Obstacle for Site Information Location: HeBei, China Capacity: 12 m 3 /h (5283 gpm) Purpose: Pretreat sea water prior to RO system Time in Operation:

More information

MEMBRANE TECHNOLOGY TREATING OILY WASTEWATER FOR REUSE

MEMBRANE TECHNOLOGY TREATING OILY WASTEWATER FOR REUSE MEMBRANE TECHNOLOGY TREATING OILY WASTEWATER FOR REUSE Jeff Peeters, P.Eng. ZENON Environmental Inc. SAWEA 2005 Workshop Al-Khobar Holiday Inn Hotel, Saudi Arabia November 29, 2005 Presentation outline

More information

Reverse Osmosis Membranes for Wastewater Reclamation By Craig R. Bartels, PhD Hydranautics, 401 Jones Road, Oceanside California, USA 92054

Reverse Osmosis Membranes for Wastewater Reclamation By Craig R. Bartels, PhD Hydranautics, 401 Jones Road, Oceanside California, USA 92054 Reverse Osmosis Membranes for Wastewater Reclamation By Craig R. Bartels, PhD Hydranautics, 401 Jones Road, Oceanside California, USA 92054 Abstract Wastewater reclamation has become a viable alternative

More information

Nine Industrial Scale V SEPs. Feed Tank V SEP. Feed Pumps (Three) Concentrate. Tank. V SEP Treatment System

Nine Industrial Scale V SEPs. Feed Tank V SEP. Feed Pumps (Three) Concentrate. Tank. V SEP Treatment System River Treatment for Ultrapure Production A cost-effective and environmentally-sound solution Abstract New Logic International installed its Vibratory Shear Enhanced Processing (VSEP) Phase I system in

More information

ROSS Technology Removal of Oil, Solids and Scale Formers

ROSS Technology Removal of Oil, Solids and Scale Formers ROSS Technology Removal of Oil, Solids and Scale Formers Frac Flowback and Produced Treatment for Reuse WATER TECHNOLOGIES Treatment for Reuse and Enhanced Oil Recovery ROSS Technology is a an effective

More information

HUBER Vacuum Rotation Membrane VRM Bioreactor

HUBER Vacuum Rotation Membrane VRM Bioreactor HUBER Vacuum Rotation Membrane VRM Bioreactor VRM The rotating plate membrane for clean water applications. The future-oriented solution designed for the ever increasing requirements in wastewater treatment

More information

MEMCOR membranes for drinking water applications. Water Technologies

MEMCOR membranes for drinking water applications. Water Technologies MEMCOR membranes for drinking water applications Water Technologies Memcor membranes Why choose membrane filtration? As ever-tightening water regulations continue to challenge the limits of conventional

More information

SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS

SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS Published in Water and Waste Digest membrane issue, November 2008 Miroslav Colic; Chief Scientist, Clean Water Technology

More information

Development of Advanced Wastewater Treatment and Reclamation System

Development of Advanced Wastewater Treatment and Reclamation System 14 Development of Advanced Wastewater Treatment and Reclamation System TAKESHI TERAZAKI *1 HOZUMI OTOZAI *2 KOSUKE SHIGIISHI *2 HIDEO SUZUKI *3 HIROSHI NAKASHOJI *4 HIROYUKI KAWAMOTO *5 Recycling and the

More information

INTEGRATED MEMBRANE SYSTEMS. Introduction

INTEGRATED MEMBRANE SYSTEMS. Introduction Wa yn e T. Bat es and Rocco Cuo zzo INTEGRATED MEMBRANE SYSTEMS Introduction The time has arrived for users of Reverse Osmosis (RO) and Nanofilter (NF) systems to re-evaluate the cost and operating benefits

More information

Mine Water Treatment Solutions for Discharge and Re-Use

Mine Water Treatment Solutions for Discharge and Re-Use Mine Water Treatment Solutions for Discharge and Re-Use Bernhard Doll Pall Corporation Summary This paper focusses on the description of reliable, safe and economical treatment of mine water from different

More information

By: Curt Roth Vice President, Engineering EconoPure Water Systems, LLC. Point of Use/Point of Entry Treatment with LFNano. An EconoPure White Paper

By: Curt Roth Vice President, Engineering EconoPure Water Systems, LLC. Point of Use/Point of Entry Treatment with LFNano. An EconoPure White Paper An EconoPure White Paper 2024 N. Broadway Santa Ana, CA 92706 USA 1+(714) 258 8559 www.econopure.com Point of Use/Point of Entry Treatment with LFNano By: Curt Roth Vice President, Engineering EconoPure

More information

Basics of Reverse Osmosis

Basics of Reverse Osmosis What is Reverse Osmosis? Reverse Osmosis is a technology that is used to remove a large majority of contaminants from water by pushing the water under pressure through a semi- permeable membrane. This

More information

Water Treatment and Reverse Osmosis Systems

Water Treatment and Reverse Osmosis Systems Water 2012 Treatment Pure Aqua, and Inc. Reverse All Rights Osmosis Reserved. ystems Worldwide Experience uperior Technology About the Company Pure Aqua is a company with a strong philosophy and drive

More information

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges Membrane Filtration Technology: Meeting Today s Water Treatment Challenges Growing global demand for clean water and increasing environmental concerns make membrane filtration the technology of choice

More information

Technical Paper Presented at Southwest Chemistry Workshop, Farmington, NM, June 23-24, 2009

Technical Paper Presented at Southwest Chemistry Workshop, Farmington, NM, June 23-24, 2009 Technical Paper Presented at Southwest Chemistry Workshop, Farmington, NM, June 23-24, 2009 Pall Integrated Membrane System Enhances Boiler Feed Water Make-Up Quality and Lowers Operating Costs Ram Karlapudi,

More information

Use of Color Removal Membranes on Waste Water Treatment in the Pulp and Paper Industry

Use of Color Removal Membranes on Waste Water Treatment in the Pulp and Paper Industry Use of Color Removal Membranes on Waste Water Treatment in the Pulp and Paper Industry R.BODA*, W.T.BATES**, C.R.BARTELS, PhD*** * HYDRANAUTICS A NITTO DENKO COMPANY, 11 Laurel Court, Glasgow G72 7BD,

More information

Pall Aria Integrated MF/RO Systems for Cost-Effective Treatment of Sea and Brackish Waters

Pall Aria Integrated MF/RO Systems for Cost-Effective Treatment of Sea and Brackish Waters Pall Aria Integrated MF/RO Systems for Cost-Effective Treatment of Sea and Brackish Waters Pall Aria Integrated MF/RO Systems for Cost-Effective Treatment of Sea and Brackish Waters Water scarcity resulting

More information

ECOAZUR BLUEWATER WATER PURIFICATION PLANTS

ECOAZUR BLUEWATER WATER PURIFICATION PLANTS ECOAZUR BLUEWATER WATER PURIFICATION PLANTS CONTACT EcoAzur Calle 11a #492 x 60 y 62 Tel: +52-999-920-1972 Col. Residencial Pensiones Email: info@eco-azur.com C.P. 97217 Merida, Yucatan, Mexico Website:

More information

Amiad s AMF² pre-treatment technology ensures efficient and reliable nanofiltration of Scottish Highland loch water

Amiad s AMF² pre-treatment technology ensures efficient and reliable nanofiltration of Scottish Highland loch water technical article Document Ref: 0411001-NFPT-text-RevG Status: Re-issued to Elsevier Science Company: Amiad Filtration Systems Limited Issue Date: 10 February 2006 Copy Deadline: 10 February 2006 Publication:

More information

Troubleshooting Your RO

Troubleshooting Your RO Troubleshooting Your RO Summary: There can be many reasons why a RO system suffers a loss in performance, and is unable to produce the proper quantity and/or quality of permeate water. Similar to a doctor

More information

Wastewater Reuse. Typical treated wastewater is:

Wastewater Reuse. Typical treated wastewater is: Wastewater Reuse Most metal finishing industries have in-house wastewater treatment to economically dispose of the acids, alkali, oils, and dissolved metals in the rinse water and occasional tank solution

More information

EASTERN IRRIGATION SCHEME, VICTORIA: OPERATION OF AN ULTRA-FILTRATION PLANT FOR A CLASS A RECYCLED WATER SCHEME. David Aitken. Earth Tech Engineering

EASTERN IRRIGATION SCHEME, VICTORIA: OPERATION OF AN ULTRA-FILTRATION PLANT FOR A CLASS A RECYCLED WATER SCHEME. David Aitken. Earth Tech Engineering EASTERN IRRIGATION SCHEME, VICTORIA: OPERATION OF AN ULTRA-FILTRATION PLANT FOR A CLASS A RECYCLED WATER SCHEME Paper Presented by : David Aitken Authors: David Aitken, Plant Operator, Liz Roder, Operations

More information

Ion Exchange Softening

Ion Exchange Softening Ion Exchange Softening Ion-exchange is used extensively in small water systems and individual homes. Ion-exchange resin, (zeolite) exchanges one ion from the water being treated for another ion that is

More information

GE Power & Water Water & Process Technologies. Water Treatment Solutions for Unconventional Gas

GE Power & Water Water & Process Technologies. Water Treatment Solutions for Unconventional Gas GE Power & Water Water & Process Technologies Water Treatment Solutions for Unconventional Gas Addressing Today s Challenges Today, corporations, individuals and governmental bodies alike are focused on

More information

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media ASME Research Committee Power Plant and Environmental Chemistry Overland Park, Kansas April 2-4, 2007 Prepared by: W. H. Stroman Primary

More information

Application Note NEW LOGIC RESEARCH. Treating Fuel Storage Tank Bottom Water With VSEP. Overview

Application Note NEW LOGIC RESEARCH. Treating Fuel Storage Tank Bottom Water With VSEP. Overview Treating Fuel Storage Tank Bottom Water With VSEP Overview Fuel storage tank bottom water (FSTBW) is one of several types of petroleum contaminated wastewater sources that can be treated using V SEP technology.

More information

Cooling Tower Sidestream Filtration A Green, Proven Cost Reduction Technology

Cooling Tower Sidestream Filtration A Green, Proven Cost Reduction Technology Cooling Tower Sidestream Filtration A Green, Proven Cost Reduction Technology TAB0411 Typical crossflow cooling tower installation Due to the large air-water interface needed to obtain good evaporative

More information

Hollow Fiber Cleaning and Storage Procedure

Hollow Fiber Cleaning and Storage Procedure BioSeparations WaterSep BioSeparations Corporation 420 Maple Street, Suite 1 Marlborough, Mass. 01752 508-970 0089 www.watersep.net Hollow Fiber Cleaning and Storage Procedure HF Element Cleaning & Storage

More information

GUIDELINES FOR LEACHATE CONTROL

GUIDELINES FOR LEACHATE CONTROL GUIDELINES FOR LEACHATE CONTROL The term leachate refers to liquids that migrate from the waste carrying dissolved or suspended contaminants. Leachate results from precipitation entering the landfill and

More information

1. Inspection and monitoring... 3

1. Inspection and monitoring... 3 1 Index 1. Inspection and monitoring... 3 1.1 Handling of new elements... 3 1.1.1 Storage of original packaged RO elements... 3 1.1.2 Packing... 3 1.2 Initial start- up checks of a plant... 3 1.2.1 Preparation

More information

Innovation and Progress in Water Treatment Technology

Innovation and Progress in Water Treatment Technology Innovation and Progress in Water Treatment Technology Degree of separation of ultrafiltration Summary of the various processes The water will be pressed through the between the raw water side and the filtrate

More information

Water Softening for Hardness Removal. Hardness in Water. Methods of Removing Hardness 5/1/15. WTRG18 Water Softening and Hardness

Water Softening for Hardness Removal. Hardness in Water. Methods of Removing Hardness 5/1/15. WTRG18 Water Softening and Hardness Water Softening for Removal 1 in Water High concentration of calcium (Ca2+) and magnesium (Mg2+) ions in water cause hardness Generally, water containing more than 100 mg/l of hardness expressed as calcium

More information

Saudi Aramco Project Development

Saudi Aramco Project Development Saudi Aramco Project Development Wastewater Treatment Facilities Jeddah Refinery And Marine Area December 2007 Facilities Planning Dept. OBJECTIVE: Provide an overview of the complexities of developing

More information

Pall Aria AP Series Packaged Water Treatment Systems

Pall Aria AP Series Packaged Water Treatment Systems Pall Aria AP Series Packaged Water Treatment Systems Pall Aria AP Series Packaged Water Treatment Systems Installations Point Hope, AK Wainwright, AK Nuiqsut, AK Point Lay, AK Atqasuk, AK Anchorage, AK

More information

Differentiation Summary. Revolutionizing Water Clean-Up Opportunities

Differentiation Summary. Revolutionizing Water Clean-Up Opportunities Differentiation Summary Revolutionizing Water Clean-Up Opportunities NanoClear is a water clean-up process that affordably and efficiently converts salt, brackish or waste water into pure, usable water.

More information

Remediation of Water-Based Drilling Fluids and Cleaning of Cuttings

Remediation of Water-Based Drilling Fluids and Cleaning of Cuttings OVERVIEW Water-Based Drilling Fluids are environmentally friendly compared with oil-based drilling fluids; however their safe disposal can still be a challenge. There are normally no hydrocarbons present,

More information

RO Reverse Osmosis equipments

RO Reverse Osmosis equipments RO SYSTEMS RO Reverse Osmosis equipments A range of Reverse Osmosis equipment designed to provide the highest performances with flow rates demand from 50 to 1000 l/h. Every component of the equipment is

More information

A Guide to Trouble-Free Cooling Towers

A Guide to Trouble-Free Cooling Towers A Guide to Trouble-Free Cooling Towers A basic understanding of cooling tower operation and maintenance will help keep a cooling water system running in top condition, year after year By David M. Suptic

More information

Produced water from oil and gas production

Produced water from oil and gas production Produced water from oil and gas production Lisa Sumi Oil and Gas Accountability Project Presentation at the 2005 People s Oil and Gas Summit Farmington, New Mexico October 28, 2005 Produced Water Any water

More information

1 Quality Assurance and Quality Control Project Plan

1 Quality Assurance and Quality Control Project Plan 1 Quality Assurance and Quality Control Project Plan The purpose of this section is to describe the quality assurance/quality control program that will be used during the system specific field testing

More information

PERFORMANCE TESTING OF A 380 ML/D RETROFITTED MEMBRANE/UV OXIDATION WTP. Introduction

PERFORMANCE TESTING OF A 380 ML/D RETROFITTED MEMBRANE/UV OXIDATION WTP. Introduction PERFORMANCE TESTING OF A 38 ML/D RETROFITTED MEMBRANE/UV OXIDATION WTP Brian Sahely, M.A.,Sc., P.Eng, AECOM Canada Ltd. 56 Cancross Court, Suite A, Mississauga, ON L5R 3E9 Brian.sahely@aecom.com Phone:

More information

Indiana s Newest Filtration Facility; East Chicago

Indiana s Newest Filtration Facility; East Chicago Indiana s Newest Filtration Facility; East Chicago Innovation and Value-Added Benefits Behind East Chicago s Membrane Treatment Facility Eric Horvath, PE and Kara M. Boyles, PhD, PE August 1, 2012 Presentation

More information

GE Power & Water Water & Process Technologies. Water and Process Solutions for the Refining Industry

GE Power & Water Water & Process Technologies. Water and Process Solutions for the Refining Industry GE Power & Water Water & Process Technologies Water and Process Solutions for the Refining Industry Maximizing Refining and Fuel Production Processes For more than 100 years, GE has maintained its commitment

More information

The Grand Miramare Hotel Santa Margherita (Portofino) Italy March 19 22, 2013. Inspiring Innovation and Excellence

The Grand Miramare Hotel Santa Margherita (Portofino) Italy March 19 22, 2013. Inspiring Innovation and Excellence The Grand Miramare Hotel Santa Margherita (Portofino) Italy March 19 22, 2013 Inspiring Innovation and Excellence About the IDA Desalination Academy The IDA Desalination Academy aspires to increase knowledge

More information

Complete. Water Solutions. for Rural India

Complete. Water Solutions. for Rural India Complete Water Solutions for Rural India More precious than gold. That s what safe drinking water is to India s rural population. Arsenic, iron, fluoride, nitrate, brackishness and pathogens in ground

More information

THE NEW NSF 350 AND 350-1

THE NEW NSF 350 AND 350-1 THE NEW NSF 350 AND 350-1 These American National Standards help in evaluating and approving water reuse treatment technologies. BY TOM BRUURSEMA Figure 1 At the NSF residential wastewater treatment system

More information

TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES

TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES JOHN F. BOSSLER, SIEMENS Water Technologies Corp., Hoffman Estates, IL RONALD TRAVIS, SIEMENS Water Technologies

More information

Highly Colored Water Removal Using Nanofiltration Membranes at the Colored Water Treatment Facility. Adam Zacheis, Project Manager Carollo Engineers

Highly Colored Water Removal Using Nanofiltration Membranes at the Colored Water Treatment Facility. Adam Zacheis, Project Manager Carollo Engineers Highly Colored Water Removal Using Nanofiltration Membranes at the Colored Water Treatment Facility Adam Zacheis, Project Manager Carollo Engineers Topics 1. Background - Mesa Water District (Mesa) Water

More information

Marina Bay on Boston Harbor Water-treatment system by OilTrap Environmental

Marina Bay on Boston Harbor Water-treatment system by OilTrap Environmental Marina Bay on Boston Harbor Water-treatment system by OilTrap Environmental Introduction to Electrocoagulation Electro------Coagulation Electro To cause a pre-determined reaction using a DC electrical

More information

Reuse of Alternative Water Sources for Cooling Tower Systems Two Case Studies Using Non-Traditional Water Sources

Reuse of Alternative Water Sources for Cooling Tower Systems Two Case Studies Using Non-Traditional Water Sources Reuse of Alternative Water Sources for Cooling Tower Systems Two Case Studies Using Non-Traditional Water Sources Matthew L. Haikalis Veolia Water Solutions & Technologies April 24, 2013 Operational Priorities

More information

Water Solutions for Upstream Oil & Gas

Water Solutions for Upstream Oil & Gas Water Solutions for Upstream Oil & Gas WATER TECHNOLOGIES Produced water project, Bahrain. Veolia Water Technologies is dedicated to creating water solutions for the global oil & gas industry Oil and gas

More information

Combination of advanced aeration system and membrane bioreactor for winery waste water treatment

Combination of advanced aeration system and membrane bioreactor for winery waste water treatment Combination of advanced aeration system and membrane bioreactor for winery waste water treatment G. Tanzi*, A. Mazzei** * Sepra S.r.l., via Como 69/A, 20031 Cesano Maderno, Italy (e-mail: gctanzi@sepra.it)

More information

WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )

WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS ) Page 1 of 76 1.0 PURPOSE The purpose of the Wastewater Treatment System is to remove contaminates from plant wastewater so that it may be sent to the Final Plant Effluent Tank and eventually discharged

More information

Microfiltration for Removal of Manganese from Surface Water

Microfiltration for Removal of Manganese from Surface Water Microfiltration for Removal of Manganese from Surface Water Carl Schneider, Ph.D., P.E., Senior Process Engineer Wiedeman & Singleton, Inc., Atlanta, GA Peter Johns, P.E., Vice-President Wiedeman & Singleton,

More information

The Fouling of Zirconium(IV) Hydrous Oxide Polyacrylate Dynamically Formed Membranes during the Nanofiltration of Lactic Acid Solutions

The Fouling of Zirconium(IV) Hydrous Oxide Polyacrylate Dynamically Formed Membranes during the Nanofiltration of Lactic Acid Solutions Membranes 213, 3, 415-423; doi:1.339/membranes34415 Article OPEN ACCESS membranes ISSN 277-375 www.mdpi.com/journal/membranes The Fouling of Zirconium(IV) Hydrous Oxide Polyacrylate Dynamically Formed

More information

Membrane Bioreactor Performance Compared to Conventional Wastewater Treatment

Membrane Bioreactor Performance Compared to Conventional Wastewater Treatment Technical Paper Membrane Bioreactor Performance Compared to Conventional Wastewater Treatment Authors: Thomas C. Schwartz and Brent R. Herring, Woodard and Curran Incorporated Ricardo Bernal and Janet

More information

e ROI Improved Membrane Bio-Reactor (MBR) performance delivers superior effluent quality and major capital savings at Latte Trento Dairy in Italy

e ROI Improved Membrane Bio-Reactor (MBR) performance delivers superior effluent quality and major capital savings at Latte Trento Dairy in Italy Essential Expertise for Water, Energy and Air Improved Membrane Bio-Reactor (MBR) performance delivers superior effluent quality and major capital savings at Latte Trento Dairy in Italy Environmental Results

More information

Environmental Technology March/April 1998

Environmental Technology March/April 1998 Treating Metal Finishing Wastewater Sultan I. Amer, Ph.D. AQUACHEM INC. Environmental Technology March/April 1998 Wastewater from metal finishing industries contains high concentrations of contaminants

More information

CONDENSATE MANAGEMENT

CONDENSATE MANAGEMENT CONDENSATE MANAGEMENT Innovative and integrated Systems Solutions Filtration Solutions from Donaldson Donaldson is a leading global manufacturer of filtration systems. The company, which was founded in

More information

GUIDELINES FOR SELECTING RESIN ION EXCHANGE OR REVERSE OSMOSIS FOR FEED WATER DEMINERALISATION

GUIDELINES FOR SELECTING RESIN ION EXCHANGE OR REVERSE OSMOSIS FOR FEED WATER DEMINERALISATION GUIDELINES FOR SELECTING RESIN ION EXCHANGE OR REVERSE OSMOSIS FOR FEED WATER DEMINERALISATION Prepared by: Purolite International Date: November 2003 Operating Puropack Plant 2 GUIDELINES FOR SELECTING

More information

Siemens Water Technologies. Walnut Shell Filters. Redesigning for Offshore Use. Michael Howdeshell Chad Felch Eric Lorge. Water Technologies

Siemens Water Technologies. Walnut Shell Filters. Redesigning for Offshore Use. Michael Howdeshell Chad Felch Eric Lorge. Water Technologies Siemens Walnut Shell Filters Redesigning for Offshore Use Michael Howdeshell Chad Felch Eric Lorge Geography -Siemens -O&G offices Slide 2 Slide 3 Agenda Walnut Shell Technology Background Testing in North

More information

Feasibility study of crystallization process for water softening in a pellet reactor

Feasibility study of crystallization process for water softening in a pellet reactor International A. H. Mahvi, Journal et al. of Environmental Science & Technology Feasibility study of crystallization... Vol. 1, No. 4, pp. 1-4, Winter 5 Feasibility study of crystallization process for

More information

Background. 179 million gallons saved for make-up water

Background. 179 million gallons saved for make-up water Essential Expertise for Water, Energy and Air Gallatin Steel Achieves Significant eroi Savings Through the Use of Nalco Innovative Technologies Background Gallatin Steel is a mini-mill that produces steel

More information

Keeping Your Swimming Pool and Spa Healthy Environmental Health Guide

Keeping Your Swimming Pool and Spa Healthy Environmental Health Guide Keeping Your Swimming Pool and Spa Healthy Environmental Health Guide A swimming pool or spa can be an asset to your home, and provide the opportunity to take part in healthy relaxing activities. However,

More information

Membrane filtration of surface water for the removal of humic substances

Membrane filtration of surface water for the removal of humic substances Membrane filtration of surface water for the removal of humic substances Marina Prisciandaro, Annarita Salladini and Diego Barba Dipartimento di Chimica, Ingegneria Chimica e Materiali, Università dell

More information

Carbon Dioxide and Dissolved Oxygen Removal From Makeup Water By Gas Transfer Membranes

Carbon Dioxide and Dissolved Oxygen Removal From Makeup Water By Gas Transfer Membranes Technical Paper Carbon Dioxide and Dissolved Oxygen Removal From Makeup Water By Gas Transfer Membranes Authors: S.H. Macklin, Northeast Utilities, W.E. Haas, GE Water & Process Technologies and W.S. Miller,

More information

How To Water System

How To Water System Mid-Monroe Water System: Soluble Iron and Manganese Removal via Oxidation & Filtration Daniel Rickard, P.E. Engineering Project Manager Pennsylvania-American Water Company Who Is American Water We are

More information

ADVANCED TREATMENT OF RAINWATER USING METAL MEMBRANE COMBINED WITH OZONATION

ADVANCED TREATMENT OF RAINWATER USING METAL MEMBRANE COMBINED WITH OZONATION ADVANCED TREATMENT OF RAINWATER USING METAL MEMBRANE COMBINED WITH OZONATION Ree Ho Kim 1*, Sangho Lee 1, Seog-Ku Kim 1, and Jong-Oh Kim 2 1 Korea Institute of Construction Technology, 2311 Deahwa-Dong,

More information

SMALL COMMUNITY TREATMENT PLANT EXPANSION WHILE IN OPERATION USING ADVANCED TECHNOLOGY

SMALL COMMUNITY TREATMENT PLANT EXPANSION WHILE IN OPERATION USING ADVANCED TECHNOLOGY SMALL COMMUNITY TREATMENT PLANT EXPANSION WHILE IN OPERATION USING ADVANCED TECHNOLOGY Adel Bassyouni, HDR Engineering, Guillermo Garcia, HDR Engineering, Don Mc Dermott, Viejas Public Works Department

More information

COOLING WATER MANAGEMENT

COOLING WATER MANAGEMENT COOLING WATER MANAGEMENT Intent To minimize the carbon-footprint, water usage and environmental impact of HVAC cooling systems and process cooling systems, generally by optimizing the control of water

More information

CERTIFICATION TO OPERATE WATER AND WASTEWATER TREATMENT SYSTEMS APPLICATION INSTRUCTIONS

CERTIFICATION TO OPERATE WATER AND WASTEWATER TREATMENT SYSTEMS APPLICATION INSTRUCTIONS COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION STATE BOARD FOR CERTIFICATION OF WATER AND WASTEWATER SYSTEMS OPERATORS CERTIFICATION TO OPERATE WATER AND WASTEWATER TREATMENT SYSTEMS

More information

Water Treatment. Session Objectives

Water Treatment. Session Objectives Water Treatment Session Objectives To demonstrate the need for treatment of surface waters and some groundwaters for drinking purposes. To introduce the concept of the multiple barrier principle and to

More information

FACT SHEET STATEMENT OF BASIS HARLEY DOME 1 PRODUCED WATER TREATMENT FACILITY UPDES PERMIT NUMBER: UT0025917 NEW PERMIT MINOR INDUSTRIAL

FACT SHEET STATEMENT OF BASIS HARLEY DOME 1 PRODUCED WATER TREATMENT FACILITY UPDES PERMIT NUMBER: UT0025917 NEW PERMIT MINOR INDUSTRIAL FACT SHEET STATEMENT OF BASIS HARLEY DOME 1 PRODUCED WATER TREATMENT FACILITY UPDES PERMIT NUMBER: NEW PERMIT MINOR INDUSTRIAL FACILITY CONTACTS Mitch Burroughs, Operator Mailing Address 1716 E. Lincoln

More information

SPE Distinguished Lecturer Program

SPE Distinguished Lecturer Program SPE Distinguished Lecturer Program The SPE Distinguished Lecturer Program is funded principally through a grant from the SPE Foundation. The society gratefully acknowledges the companies that support this

More information

Seccua Product Presentation

Seccua Product Presentation Seccua Product Presentation Technology Membrane Technology Color Turbidity Endocrines Bacteria Virus Dissolved Solids 1000 nm 100 10 1 0,1 nm 100 µm 10 1 0,1 0,01 0,001 µm Reverse Osmosis dp = 15 bar 80

More information

SEAR Wastewater Treatment: Contaminant Removal and Material Recovery

SEAR Wastewater Treatment: Contaminant Removal and Material Recovery ESTCP SEAR Wastewater Treatment: Contaminant Removal and Material Recovery U.S. Environmental Protection Agency National Risk Management Research Laboratory Cincinnati, Ohio SEAR Workshop Outline Motivation

More information

Removing Heavy Metals from Wastewater

Removing Heavy Metals from Wastewater Removing Heavy Metals from Wastewater Engineering Research Center Report David M. Ayres Allen P. Davis Paul M. Gietka August 1994 1 2 Removing Heavy Metals From Wastewater Introduction This manual provides

More information

Case Study NEW LOGIC RESEARCH. Using Vibrating Membranes to Treat Oily Wastewater from a Waste Hauling Facility

Case Study NEW LOGIC RESEARCH. Using Vibrating Membranes to Treat Oily Wastewater from a Waste Hauling Facility NEW LOGIC RESEARCH Using Vibrating Membranes to Treat Oily Wastewater from a Waste Hauling Facility Overview A unique membrane filtration system has been installed at several major waste oil hauling operations

More information

Contract No: Disclaimer:

Contract No: Disclaimer: Contract No: This document was prepared in conjunction with work accomplished under Contract No. DE-AC09-09SR22505 with the U.S. Department of Energy (DOE) National Nuclear Security Administration (NA).

More information

Engineered Media for Removal of Fission Products from Aqueous Streams 14580. Abigail Holmquist, UOP - A Honeywell Company

Engineered Media for Removal of Fission Products from Aqueous Streams 14580. Abigail Holmquist, UOP - A Honeywell Company Engineered Media for Removal of Fission Products from Aqueous Streams 14580 Abigail Holmquist, UOP - A Honeywell Company ABSTRACT Nuclear fission products from fuel have the potential to be released into

More information

Cartridge Filter Application Notes

Cartridge Filter Application Notes Industrial Water Purification (800) CAL-WATER Cal Water 1961 Petra Lane Placentia, CA 92870 FAX: (714) 792-0794 Web Page / Email: www.cal-water.com Cartridge Filter Application Notes Cal Water offers a

More information

RO / NF Cleaning Guidelines

RO / NF Cleaning Guidelines Nanostone Water, Inc. Carlsbad Office 2463 Impala Dr. Carlsbad, CA 92010 USA T: +1 (844) 765-7377 www.nanostone.com RO / NF Cleaning Guidelines 2015 Nanostone Water, Inc. www.nanostone.com RO/NF Cleaning

More information

Ion Exchange Design Hand calculation. Brian Windsor (Purolite International Ltd)

Ion Exchange Design Hand calculation. Brian Windsor (Purolite International Ltd) Ion Exchange Design Hand calculation Brian Windsor (Purolite International Ltd) Introduction Before design programmes were introduced, every engineer had to calculate the design by hand using resin manufacturers

More information

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction Reverse Osmosis Parts Introduction Reverse Osmosis Flow Chart AQUAPRO INDUSTRIAL CO.,LTD Triple Membrane WATER IMPROVER WATER IMPROVER 2 Reverse Osmosis Electrical Diagram AC-220V Power (2.0 point) (W)

More information

Technical Bulletin // Up-Flo Filter

Technical Bulletin // Up-Flo Filter Technical Bulletin // Up-Flo Filter Evaluation of Sil-Co-sil 106 Removal Performance using cpz mix tm media 2006 Hydro International 94 Hutchins Drive Portland, ME 04102 Tel: 207.756.6200 Fax: 207.756.6212

More information

Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities

Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities Water Efficiency Water Management Options Boilers for Commercial, Industrial and Institutional Facilities Boiler Water Impurities All boiler make-up water contains impurities. As clean steam is released

More information

BHS CANDLE FILTER APPLICATIONS FOR CLARIFICATION / RECOVERY OF SOLIDS FROM CHEMICAL SLURRIES

BHS CANDLE FILTER APPLICATIONS FOR CLARIFICATION / RECOVERY OF SOLIDS FROM CHEMICAL SLURRIES FOR CLARIFICATION / RECOVERY OF SOLIDS FROM CHEMICAL SLURRIES TABLE OF CONTENTS 1. FINE CATALYST RECOVERY AT A REFINERY Pages 2 4 2. FINE SOLIDS REMOVAL & CLARIFICATION OF A SPECIALIZED ACIDIC SOLVENT

More information

Portable Swimming Pool Reverse Osmosis Systems

Portable Swimming Pool Reverse Osmosis Systems Portable Swimming Pool Reverse Osmosis Systems C. Brent Cluff, Ph.D. Clean Water Products A standard practice for pool owners is to periodically drain the swimming pool to reduce calcium and magnesium

More information

Water Info. What is Reverse Osmosis?

Water Info. What is Reverse Osmosis? Water Info What is Reverse Osmosis? Anyone who has been through a high school science class will likely be familiar with the term osmosis. The process was first described by a French Scientist in 1748,

More information

Total Water & Wastewater Management for Shale Gas Production. Treatment and Operation Solutions

Total Water & Wastewater Management for Shale Gas Production. Treatment and Operation Solutions Total Water & Wastewater Management for Shale Gas Production Treatment and Operation Solutions Impact of Water and Wastewater from Shale Gas Fracturing Operations As the number of shale gas fracturing

More information

WISCONSIN WASTEWATER OPERATORS ASSOCIATION

WISCONSIN WASTEWATER OPERATORS ASSOCIATION Integrity. People. Knowledge. WISCONSIN WASTEWATER OPERATORS ASSOCIATION ANNUAL CONFERENCE GREEN BAY Resources. MEETING LOW LEVEL PHOSPHORUS LIMITS BY CHEMICAL ADDITION WHAT IS PHOSPHORUS Atomic # 15 Electron

More information

CWD BALDWIN PLANT NEW RESIDUALS HANDLING SYSTEM

CWD BALDWIN PLANT NEW RESIDUALS HANDLING SYSTEM CWD BALDWIN PLANT NEW RESIDUALS HANDLING SYSTEM OTCO Water Workshop March, 2011 Frank Woyma Plant Manager Nick Pizzi Vice-President EE&T ENVIRONMENTAL ENGINEERING & TECHNOLOGY, INC. Objectives Review the

More information

WASTEWATER TREATMENT OBJECTIVES

WASTEWATER TREATMENT OBJECTIVES WASTEWATER TREATMENT OBJECTIVES The student will do the following: 1. Define wastewater and list components of wastewater. 2. Describe the function of a wastewater treatment plant. 3. Create a wastewater

More information

A meaningful, cost-effective solution for polishing reverse osmosis permeate

A meaningful, cost-effective solution for polishing reverse osmosis permeate A meaningful, cost-effective solution for polishing reverse osmosis permeate Electrodeionization or EDI, is a continuous and chemicalfree process of removing ionized and ionizable species from the feed

More information

Life Sciences USD 2260. High Purity Water Systems for the Biopharmaceutical Industry. Improving security, flexibility and operation costs

Life Sciences USD 2260. High Purity Water Systems for the Biopharmaceutical Industry. Improving security, flexibility and operation costs Life Sciences USD 2260 High Purity Water Systems for the Biopharmaceutical Industry Improving security, flexibility and operation costs Pall's total turnover is more than $1.5billion. Our staff of more

More information

To meet the demands of a high-purity deionized (DI) water system, filters must:

To meet the demands of a high-purity deionized (DI) water system, filters must: Ultrapure Water General Filter Requirements Achieving and maintaining ultrapure water (UPW) is extremely important in light of its widespread presence throughout the manufacture of semiconductor integrated

More information

Parker Hannifin Corporation Process Advanced Filtration Division 2340 Eastman Avenue Oxnard, California 93030 USA

Parker Hannifin Corporation Process Advanced Filtration Division 2340 Eastman Avenue Oxnard, California 93030 USA UF Cleaning Procedures 1 Formulas For Cationic (Cathodic) Paints Purpose Circ. Time Formulation(% by vol*) CC-1 Normal paint fouling 1-2 hours! 91.65% DI or RO Water 90-120 F! 3.0% Butyl Cellosolve! 5.0%

More information

Hardness ions also interfere with many chemical processes such as chemical compounding and aqueous cleaners.

Hardness ions also interfere with many chemical processes such as chemical compounding and aqueous cleaners. Water Softeners Industrial Water Purification (800) CAL-WATER By Dave Peairs, Cal Water, Technical Director Rev: 06/08/2004 Before any discussion of water softeners, we must first define what hard water

More information

Tampa Bay Seawater Desalination Plant

Tampa Bay Seawater Desalination Plant Tampa Bay Seawater Desalination Plant Project History How The Plant Works Desal Fun Facts 2575 Enterprise Road, Clearwater, FL 33763-1102 Phone: 727.796.2355 / Fax: 727.791.2388 www.tampabaywater.org Tampa

More information