VWR Autosampler Vials, Inserts and Closures. When Reliability is Key
|
|
- Arnold Mathews
- 7 years ago
- Views:
Transcription
1 VWR Autosampler Vials, Inserts and Closures When Reliability is Key
2 The WebSeal System WebSeal System has the most comprehensive range of covers for all micro titer plate configurations. The WebSeal closure system reseals around the needle even after multiple aliquots have been taken preventing sample loss. Vials from 500 µl to 1.5 ml capacity for both 96 round and square well plates can be used with the WebSeal covers. Convenient wellplate kits with pre-inserted glass or PTFE vials Replacement vials for kits available separately Unique cutting tool allows removal of individual samples with the seal in place, eliminating cross contamination Kits are packaged with vials pre-assembled along with a pack of 5 wellplate covers NEW 96 Wellplate with 650 µl tapered glass vials pre-inserted, 5 mats and cutting tool 96 Wellplate with 1.1 ml crimp top vials pre-inserted, 5 mats and cutting tool 96 Well plate with 650 µl tapered PTFE vials pre-inserted, 5 mats and cutting tool Cutting tool Replacement Vials 96 Wellplate 650 µl tapered glass replacement vials 96 Wellplate 1.1 ml crimp top replacement vials 96 Wellplate 650 µl tapered PTFE replacement vials WebSeal Mats Manufactured from PTFE coated silicone Superior resealability up to 100 injections Eliminates cross contamination of samples Dry heat autoclavable with excellent chemical compatibility 96 Round well dome based WebSeal mats Round well flat based WebSeal mats Square well dome based WebSeal mats Square well flat based WebSeal mats Round well flat based WebSeal mats Square well flat based WebSeal mats
3 Welcome to the VWR Chromatography brochure. This brochure represents the complete line of VWR autosampler vials and accessories offered. Vial choices include: screw top, crimp/snap, headspace and speciality vials with a large selection of closures. Refer to the Autosampler Compatibility Table on pages 18 and 19 to determine which vials, closures and inserts will work on your specific autosampler unit. VWR Certified Vial Convenience kits VWR is excited to introduce NEW Certified Vial Convenience kits that come complete with vials, closures and a certificate of conformance. These kits offer the extra quality assurance that time after time the vials and closures will perform at a superior level. Bonded caps prevent septum slippage during needle penetration. With a comprehensive product offering, multiple instruments can be accommodated using VWR Certified Kits NEW Certificate of Conformance in every pack Fully lot tested including GC and HPLC analysis Bonded caps prevent septa push-through Compatible with every autosampler 1.8 ml Clear Glass with Marking Spot and mm Bonded PTFE/Silicone closure 1.8 ml Clear Glass with Marking Spot and mm Bonded Pre-Slit PTFE/Silicone closure 1.8 ml Amber Glass with Marking Spot and mm Bonded PTFE/Silicone closure 1.8 ml Amber Glass with Marking Spot and mm Bonded Pre-Slit PTFE/Silicone closure 1.5 ml High Recovery Clear Glass Vial with Gray cap Bonded PTFE/Silicone pre-slit septa 1.5 ml High Recovery Clear Glass Vial with Black cap Bonded PTFE/Silicone septa 1.8 ml Clear Glass Vial with Blue cap PTFE/Silicone septa 900 µl Precision Taper Clear Glass Vial with Black cap Bonded PTFE/Silicone septa 3
4 1.8 ml 12 x 32 mm Standard Opening Crimp Vials and Closures 11 mm Aluminum Seal Finish Standard opening 12 x 32 mm vials with 11 mm aluminum seal finishes. Clear vials are made from Type 1, Class A, borosilicate glass. Amber vials are made from 51A amber borosilicate glass. Available with or without marking spots. For Agilent, Hitachi, PerkinElmer, Shimadzu, Varian and Waters autosamplers. 1.8 ml Clear Glass ml Clear Glass with Marking Spot ml Amber Glass ml Amber Glass with Marking Spot VWR 11 mm Aluminum Seals Aluminum Seals provide secure closures even when using volatile solvents. PTFE/Natural Red Rubber PTFE/Silicone Red PTFE/Silicone / Red PTFE mm Inserts VWR offers a complete line of inserts for your microsampling needs, specifically engineered for use with our standard opening aluminum seal vials. 0.2 ml Conical, Glass with Spring ml Conical, Glass ml Flat Bottom, Glass ml Large Opening Crimp Vials and Closures 12 x 32 mm VWR Specialty Vials 12 x 32 mm Crimp Vials for applications where available sample volume is limited. 250 µl Fused Insert Vial, Clear with Marking Spot µl Fused Insert Vial, Amber with Marking Spot µl Polypropylene Vial VWR Convenience Kits Each kit contains 1.8 ml clear glass vials and aluminum seals in one easy to use package. PTFE/Synthetic Red Rubber Seal PTFE/Natural Red Rubber Lined Seal PTFE/Silicone Lined Seal Red PTFE/Silicone/Red PTFE Lined Seal
5 1.8 ml Large Opening Crimp Vials 12 x 32 mm VWR 11 mm Crimp Vials 12 x 32 mm vials feature 40% larger openings and 11 mm aluminum seal finishes. Clear vials are made from Type 1, Class A, borosilicate glass. Amber vials are made from 51A amber borosilicate glass. 1.8 ml Clear Glass ml Clear Glass with Marking Spot ml Amber Glass ml Amber Glass with Marking Spot mm Aluminum Seals Alumninum Seals provide secure closure even when using volatile solvents. These seals fit all 11 mm crimp vials. PTFE/Synthetic Red Rubber Seals offer improved performance through lower background extractables. PTFE/Natural Red Rubber Liner PTFE/Silicone Liner Red PTFE/Silicone/Red PTFE Liner PTFE/Synthetic Red Rubber, Silver Inserts, 6 mm VWR offers a complete line of inserts for your microsampling needs, specifically engineered for use with our Large Opening vials ml Conical, Glass with spring ml Conical, Polypropylene w/spring ml Conical, Glass ml Flat Bottom, Glass ml Flat Bottom, Polypropylene Call the VWR Chromatography Hotline VWR-LINE (option 2) 5
6 1.8 ml Large Opening Crimp/Snap Vials 12 x 32 mm For use with 11 mm Snap Caps or 11 mm Aluminum Seals Vials feature 40% larger openings and 11 mm Aluminum Seal Crimp / Snap-Ring finishes. Clear vials are made from Type 1, Class A, borosilicate glass. Amber vials are made from 51A amber borosilicate glass. For Agilent, Hitachi, PerkinElmer, Shimadzu, Varian and Waters autosamplers. 1.8 ml Clear Glass ml Clear Glass with Marking Spot ml Amber Glass ml Amber Glass with Marking Spot mm Snap Caps for Crimp/Snap-Ring LOVials Snap Cap closures provide a secure seal for all but the most volatile solvents. Snap Caps are easy to apply and easy to remove with no tools. PTFE/Red Rubber, Natural PTFE/Silicone, Natural Pre-Slit PTFE/Silicone, Natural VWR Convenience Kits. Each kit contains 1.8 ml clear glass vials and snap cap closures in one easy to use package. PTFE/Red Rubber Snap Cap Closure Red PTFE/Silicone Snap Cap Closure
7 8 x 40 mm Shell Vials and Closures 8 x 40 mm shell vials are made from low extractable borosilicate glass. These 1 ml vials are designed for use with Waters 96-Position trays 1 ml Clear with Natural Closure ml Amber with Natural Closure Sample pack of VWR vials and closures x 35 mm Positive Displacement Vials 8 x 35 mm vial is made from Type 1, N51A clear borosilicate glass for use on Alcott autosamplers ml Clear Glass with Plug
8 1.8 ml Standard Opening Screw Thread Vials, Thread Finish, 12 x 32 mm Standard opening screw thread vials feature an thread finish. Clear vials are made from Type 1, Class A, borosilicate glass. Amber vials are made from 51A amber borosilicate glass. Available with or without marking spots. For Hitachi, PerkinElmer, Shimadzu, Varian and Waters 2690 autosamplers. 1.8 ml Clear Glass ml Clear Glass with Marking Spot ml Amber Glass ml Amber Glass with Marking Spot Pre-Assembled Open Top Closures with Septa, Flanged caps are designed to fit Japanese autosampler trays. They are also compatible with many other instruments--see the Autosampler chart on pages 18 & 19 for more details. Black Phenolic, Red PTFE/Silicone Black Polypropylene, Red PTFE/Silicone mm Inserts 5 mm inserts fit securely into standard opening vials. Springed Conical inserts are self centering and provide a cushion against needle penetration. 0.2 ml Conical, Glass with Spring ml Conical, Glass ml Flat Bottom, Glass VWR Convenience Kits Convenience kits make ordering easy. Each kit contains vials and pre-assembled closures in one easy to use package. Select closure type from the table below. All kits listed below come with 1.8 ml Clear Glass vials and Screwthread Closures. Red PTFE/Silicone with Phenolic closure Red PTFE/Silicone with Polypropylene closure VWR Pre-assembled Vial Kits Each kit contains 1.8 ml clear glass vials with attached screwthread closures. Red PTFE/Silicone with Phenolic closure Red PTFE/Silicone with Polypropylene closure
9 1.8 ml Screw Thread Finish Vials, 12 x 32 mm Consolidate your lab with the one autosampler vial that does it all. The robotic vial offers the convenience of a large opening screw thread and a profile specifically designed for robotic arm autosamplers. Clear vials are made from Type 1, Class A, borosilicate glass. Amber vials are made from 51A amber borosilicate glass. For Agilent, PerkinElmer, Varian and Waters 2690 autosamplers. VWR Screw Thread Vials 1.8 ml Clear glass, ml Clear glass with Marking spot, ml Amber glass, ml Amber glass with Marking spot, Pre-Assembled Color Coded Closures with Septa PTFE/Red Rubber, Black Cap PTFE/Silicone, Black Cap PTFE/Silicone / PTFE, Black Cap Pre-Slit PTFE/Silicone, Black Cap mm Inserts VWR offers a complete line of inserts for your microsampling needs, specifically engineered for use with these vials ml Conical, Glass with spring ml Conical, Polypropylene w/spring ml Conical, Glass ml Flat Bottom, Glass ml Flat Bottom, Polypropylene VWR Convenience Kits Each kit contains 1.8 ml clear glass vials and screw thread closures in one easy to use package. All kits come with 1.8 ml Clear Glass vials PTFE/Red Rubber with Polypropylene closure Red PTFE/Silicone / Red PTFE with Polypropylene closure Red PTFE/Silicone with Polypropylene closure VWR Pre-assembled Vial Kits Each kit contains 1.8 ml clear glass vials with attached screwthread closures. PTFE/Red Rubber with Polypropylene closure Red PTFE/Silicone / Red PTFE with Polypropylene closure Red PTFE/Silicone with Polypropylene closure
10 1.8 ml Wide Opening Screw Thread Vials, 12 x 32 mm, VWR Wide Opening Screw Thread Vials, 12 x 32 mm, Screwthread vials feature a 40% larger opening for easier sample filling. Clear vials are made from Type, 1 Class A, borosilicate glass. Amber vials are made from 51A amber borosilicate glass. Available with or without marking spots. 1.8 ml Clear glass, ml Clear glass with Marking spot, ml Amber glass, ml Amber glass with Marking spot, VWR Pre-Assembled Open Top Closures with Septa, Black Polypropylene, PTFE/Silicone Black Polypropylene, Pre-slit PTFE/Silicone ml Screw Thread Vials for Waters 48-Position and Shimadzu, Thread Finish These 4 ml, 15 x 45 mm screw thread vials feature a thread finish and are made from Type 1, Class A, borosilicate glass. Available in clear or amber glass, with or without a marking spot. For Shimadzu, Waters and other autosamplers fitted with 15mm diameter opening trays. VWR Screw Thread Vials 4 ml Clear glass ml Clear glass with Marking spot ml Amber glass ml Amber glass with Marking spot VWR Pre-Assembled Open Top Closures with Septa, Red PTFE/Silicone, Polypropylene, Pre-Slit PTFE/Silicone, Polypropylene, White cap Red PTFE/Silicone, Phenolic, VWR Convenience kit w/ Pre-assembled Closure Kit contains 4 ml Clear glass vial Red PTFE/Silicone w/ Polypropylene Closure VWR Pre-Assembled Vial kit Each kit contains 4 ml clear glass vials and screw thread closures in one easy to use package. Red PTFE/Silicone with Polypropylene Closure
11 Magnetic Headspace Vials and Caps NEW Now available in both crimp and screw top headspace vials the magnetic caps are compatible with CTC/LEAP and GERSTEL instruments. Composite bi-metal magnetic crimp caps for easy crimping and decapping. A wide variety of septa are available for every headspace analysis. Magnetic Crimp Caps Aluminum skirt on bi-metal caps provide easy crimping Tin plate center for magnetic pick up 8mm center opening provides large target area and easy inspection of septum Internal rim contoured to conform to the beveled edge of the vial for secure seal Magnetic Screw Caps Preassembled closures minimize contamination during sample preparation PTFE/silicone septa is a thin, soft durometer seal designed for SPME applications 10 ml Clear Glass Round Bottom Screw Thread Headspace Vial 20 ml Clear Glass Round Bottom Screw Thread Headspace Vial 18 mm Magnetic Screw Cap with molded natural PTFE/blue silicone septa 18 mm Magnetic Screw Cap with cut disk white PTFE/blue chlorobutyl septa 18 mm Magnetic Screw Cap with soft durometer white PTFE/blue silicone septa 20 ml Clear Glass vial and blue magnetic combi-seal with PTFE/silicone septa (kit) 20 ml Clear Glass vial and silver tine magnetic cap with PTFE/Butyl Pharma-Fix septa (kit) Call the VWR Chromatography Hotline VWR-LINE (option 2) 11
12 Let VWR Lighten Your Load! VWR International now offers you unrivaled access to the world's leading suppliers of Chromatography products and services. Our list of manufacturers and suppliers reads like a 'who's who' of the Chromatography and Filtration Industries Agilent Technologies, Beckman Coulter, Biotage, EMD Chemicals, ES Industries, Hamilton, Mallinckrodt Baker, Merck KGaA, National Scientific, Optimize, Pall Life Sciences, SGE, Spectrum Laboratories, Sun SRI, 3M, Upchurch, Restek, Whatman, Wheaton and dozens more! Working closely with our world-class suppliers and VWR's general sales force is our field-based team of dedicated Chromatography Specialists. With more than 100 years of combined lab expertise, they're ready to provide support for your chromatography applications and answer your sample prep questions. We ll help you with your heavy decisions, choosing the right LC and GC columns and selecting from our comprehensive offering of unique and alternative accessories, supplies and repair parts from our just released VWR Chromatography & Filtration Catalog. Our in-house telephone tech support specialists will provide the quick answers you often need to those urgent questions that threaten to disrupt your busy day. Let VWR help ease the strain. Contact the hotline at VWR-LINE (option 2 for Chromatography/Filtration). For more information, call or visit 12
13 Custom Cleaning Services Custom Cleaning We have the flexibility to meet your cleaning requirements, whether your cleaning needs are for high volumes or smaller quantities. We have the capability to clean clear/amber glass or plastic containers, as well as closures or other component parts. Send us your containers and closures, or purchase from our extensive line of standard and custom products. We can process containers from 100 µl to 20 L. All cleaning services and packaging can be done in our certified class 100/10 cleanroom with full traceability and GMP compliance. 13
14 Custom Cleaning Services Silanization Services Our line of ready-to-use silanized vials, culture tubes and autosampler inserts, save valuable time and minimize costs when performing quantitative analysis or storing materials. Applications: Trace organic analysis Storage of materials prone to adhering to glass Extraction glassware Siliconization Service Siliconized products are physically coated with a medical-grade silicone emulsion to prevent sample material from reacting with the glass container. Applications: Proteins Assays of blood serum Pharmacological assays of therapeutic drugs Silanization how do we do it? A methysilylating agent is introduced by vapor phase deposition onto the surface of the disposable glassware. The silylating agent reacts with active groups on the surface of the glass effectively tying up these sites so they are less reactive. This treatment inhibits materials from adhering onto the surface of the container, allowing for maximum recovery of trace analyte. Clean Room Process Irradiation Sterile foil-wrap Steam sterilization Depyrogenation Silanization Siliconization Injectable or parenteral drugs Lyophilization Final packaging prior to drug delivery Stability studies Clinical trials Proteins Assays of blood serum Pharmacological asays of therapeutic drugs 14
15 Custom Cleaning Services Depyrogenated Glass/Depyrogenation Service VWR provides glass vials and other containers that have been specially prepared to meet endotoxin levels of less than 0.06 EU/mL. A variety of sizes are available. Depyrogenated vials and containers may also be requested with additional certifications. VWR can depyrogenate any glass as a service. The process uses dry heat at 250 degrees Celsius for a minimum of two and one half-hours. Cleaning and packaging is performed inside a Class 100 cleanroom. Applications: Non-parenteral uses such as water sampling and testing of endotoxins. Storage of packaging of terminally sterilized articles. Storage of lab reagents and media Sterilization Services We offer a number of sterilization services to effectively destroy all viable forms of life, including bacterial spores to a sterility assurance level (SAL) of 106. Services include gamma irradiation, dry-heat, autoclave or e-beam. Applications: Injectable or parental drugs Lyophilization Final packaging prior to drug delivery Stability studies Clean Process Vials Low Carbon (TOC) Vials We offer low-level certified vials for Total Organic Carbon testing and sampling. Major TOC instrument manufacturers use and recommend our vials. We offer several sizes of containers including the popular 40 ml autosampler vials cleaned, certified and ready to use. Each lot of vials is tested and certified to contribute no more than 10 ppb TOC as background. Certificate of Analysis included. Off-line and gram sampling of high autosamplers Low background is perfect for preparation and storage of standards Cleaning validation is simplified and costs are reduced by using the TOC method of testing Sterile Empty Vials Certified depyrogenated and sterile vials are available in sizes from 1 ml to 100 ml. Sterile vials are Type 1 borosilicate, assembled with butyl stoppers and aluminum seals. Sterilization is performed in a FDA licensed facility, practicing GMPs. Suitable for a number of uses where aseptic protocol is required Sterile Vials clear finish, pyrogen tested with certificate of sterility Customized analytical parameters may include special GC, GC/MS, ICP/MS, ICP, AA, GF-AA or other testing. 15
16 Clean Process Containers Low-Particle Containers VWR vials and containers are certified to contain fewer than 5 particles per milliliter larger than 0.5 microns. This exceeds the USP <788> specifications for particle content of containers. Cleaning and packaging is performed inside a Class 100 cleanroom. Class 100, double bagged glass bottles are assembled with low-shedding, polypropylene caps with chemically inert PTFE faced liners that do not contain adhesives. Storage and packaging of chemicals, reagents, powders etc. Excellent for preparation and storage of standards Double-bagged to ensure no contaminates are introduced to the clean room Off-line deionized water and chemical sampling for particle analysis Amber glass protects light-sensitive chemicals Ready for sterilization The United States Pharmacopeia issued new guidelines in Method 643 making TOC analysis mandatory. The modification as published in the Fifth Supplement to the USP/NF 23 states that the glassware to be used must be scrupulously cleaned of organic matter to reduce contamination. Our TOC vials are prepared by a proprietary method to reduce background contamination to less than 10ppb TOC. Certificate of Analysis included with all custom processes 16
FREE SAMPLE PACK Just ask.
FREE SAMPLE PACK Just ask. 2015 CHEMGLASS CERTIFIED 9MM THREADED 12 X 32MM VIALS Universally compatible with almost all autosamplers, the vials have an opening that is 40% larger than standard 8mm thread.
More informationSample Vials and Accessories. [ For all ACQUITY UPLC, HPLC, and GC Systems ]
Sample Vials and Accessories [ For all ACQUITY UPLC, HPLC, and GC Systems ] Waters Sample Vials and Accessories Quality vials are essential for reliable analytical results. All Waters Certified Vials are
More informationGENERAL CHROMATOGRAPHY. Your Essential Resource for Supplies
GENERAL CHROMATOGRAPHY Your Essential Resource for Supplies GENERAL CHROMATOGRAPHY SUPPLIES Minimize contamination and ensure accurate, reproducible results As the world s premier measurement company,
More informationThermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment
Thermo Scientific Capitol Vial Drugs of Abuse Products The tools to create and maintain a safe and drug free environment Drugs of Abuse Specimen Collection We are a world leading manufacturer of Drugs
More informationSamco Scientific Liquid Handling Solutions
1 Samco Scientific Liquid Handling Solutions Our products have been delivering quality, safety and craftsmanship to the clinical, research and industrial markets since 1971. Our comprehensive range of
More informationT100. BioTube Rack. Rack is made of 3 components: A white base A removable grid plate that can hold individual or strips of tubes A translucent cover
BiotubeTM System Simport offers a wide choice of racks containing 96 x 1.2 ml tubes (8.8 mm top dia. x 45 mm H, or strips of 8 or 12. Tubes, strips, caps and boxes are available as separate units as well.
More informationEUROTUBO DELTALAB 4. PETRI DISHES AND LOOPS
77 78 90 x 14 mm Petri Dish Made in polystyrene. Vented. Supplied in groups of 20 units, packaged in heat sealed bags. Code 200200 is ASEPTIC. Code 200209 is sterile by gamma radiation. Suitable for automatic
More informationVials and Accessories
Vials and Accessories Wide range of vials and caps High quality products Short delivery time Custom made products available on request High Power Electronic Crimpg Tool The High Power Electronic Crimper
More informationHow To Test For Leachables
Current FDA Perspective on Leachable Impurities in Parenteral and Ophthalmic Drug products AAPS Workshop on Pharmaceutical Stability Scientific and Regulatory Considerations for Global Drug Development
More informationScrew Cap Micro Tubes
Screw Cap Micro Tubes For transport, storage and sample preparation Reliable quality and versatility Sicherheit Uncompromising... quality and purity Sicherheit... Over 30 years ago, Sarstedt introduced
More informationGas Chromatography Liner Selection Guide
Gas Chromatography Liner Selection Guide Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20551 Key Words Liner, focus Abstract The liner serves an important function in allowing
More informationCataLoG No. weight o.d. i.d. GLaSSwaRe
Lead weights with Vikem Vinyl Coating Protect and Stabilize Expensive Glassware Stabilizes vessels in water baths and on benchtops Added insurance against tipping and possible chemical spills Closed ring
More informationGC-xt. The most flexible GC /GC-MS liquid sample injector
GC-xt Prep and Load Platform The most flexible GC /GC-MS liquid sample injector Environmental Foods/Beverages Consumer Products Forensics Petrochemicals/Polymers Pharmaceuticals GC-xt Liquid mode Prep
More informationSyringe Selection Guide
Syringe Selection Guide Syringe Selection Guide Manufacturer Type Page # Hamilton Syringes Series 600 General purpose, 2.5µL to 5µL 338 Series 700 General purpose, 5µL to 500µL 338 Series 900 Economical
More informationMEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process
- Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples
More informationSyringes 5. Contents. Autosampler 6. MEPS 18 Product Data 18 Part Numbers 19. Manual 20. Guided Plunger 24 Product Data 24 Part Numbers 25
Syringes Injection Port Contents Syringes 5 Autosampler 6 Diamond Headspace 6 Product Data 6 Part Numbers 7 Diamond MS 8 Product Data 8 Part Numbers 9 GC Autosampler 11 Product Data 11 Part Numbers 12
More informationFilter Vials. Product Knowledge. PTFE PVDF Nylon PES. Pat. US #7,790,117 Worldwide patents pending. Thomson Instrument Company Toll Free 800 541.
Product Knowledge Filter Vials PTFE PVDF Nylon PES.2µm.45µm.2µm.45µm.2µm.45µm.2µm.45µm Pat. US #7,790,117 Worldwide patents pending Thomson Instrument Company Toll Free 800 541.4792 Email folks@htslabs.com
More informationTESTIMONIAL: Congratulations! Our company s EID Incoming Inspection of AMRESCO-provided products
custom solutions With markets changing so rapidly, AMRESCO is on the front line bringing new technologies and processes so we can deliver solutions that solve our customers problems. TESTIMONIAL: Congratulations!
More informationPrecision Vise Combinations
Precision Vise Combinations PanaVise vises and work holding tools have hundreds of uses limited only by your imagination! Each vise allows the head to Tilt, Turn & Rotate and position your work anywhere
More informationPharma&Biotech. Endotoxin Challenge Vials Endotoxin Indicator for Depyrogenation. Translated versions available at www.lonza.com
Pharma&Biotech Endotoxin Challenge Vials Endotoxin Indicator for Depyrogenation Translated versions available at www.lonza.com Content Section Page No. 1 Intended Use 2 1 Explanation of Test 2 1 Reagents
More informationwww.gbo.com/bioscience Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-
www.gbo.com/bioscience 11 Cryotechnics Technical Information 11 I 2 Cryo.s TM 11 I 3 Cryo.s TM 1 ml 11 I 3 Cryo.s TM 2 ml 11 I 3 Cryo.s TM 4 ml 11 I 4 Cryo.s TM 5 ml 11 I 4 Support Rack 11 I 5 Cryo Storage
More informationAnalysis of Liquid Samples on the Agilent GC-MS
Analysis of Liquid Samples on the Agilent GC-MS I. Sample Preparation A. Solvent selection. 1. Boiling point. Low boiling solvents (i.e. b.p. < 30 o C) may be problematic. High boiling solvents (b.p. >
More informationSterile Cleanroom Management
Sterile Cleanroom Management Lynn Stanard, Sr. Quality Manager, Berkshire Corporation When manufacturing in an aseptic environment, it is critical to ensure that the various cleanroom consumables, such
More informationImproving Uptime in Aseptic Processing of Pharmaceutical Liquids with Blow-Fill-Seal
Improving Uptime in Aseptic Processing of Pharmaceutical Liquids with Blow-Fill-Seal Maximized uptime, minimized changeover time and efficient OEE are key factors that have influenced the acceptance of
More informationCleaning validation of cleanrooms and preparation equipments
Cleaning validation of cleanrooms and preparation equipments Head of production Central Pharmacy, Geneva University Hospitals EAHP Foundation Seminar: Patient Safety; More About Compounding" 23-25 May,
More informationCleanroom. For. Sterile Manufacturing Facilities
Cleanroom For Sterile Manufacturing Facilities Praphon Angtrakool Food and Drug Administration 1 WHO TRS No. 823 Annex 1, 1992 (1) General 17.1 The production of sterile preparations should be carried
More informationThermo Scientific Nunc Products for InVitro Fertilization. security, safety and reproducibility. for your valuable. samples
Thermo Scientific Nunc Products for InVitro Fertilization security, safety and reproducibility for your valuable samples The criteria for an IVF product is that it is reliable and does not offer any threat
More informationAxyPrep TM Mag PCR Clean-up Protocol
AxyPrep TM Mag PCR Clean-up Protocol Intro The AxyPrep Mag PCR Clean-up kit utilizes a unique paramagnetic bead technology for rapid, high-throughput purification of PCR amplicons. Using this kit, PCR
More informationThermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers. Automation, sample preparation. Autosamplers for Ion Chromatography
Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers Automation, sample preparation Autosamplers for Ion Chromatography Dionex AS-AP Autosampler Advanced Features Perform full-loop, partial-loop,
More informationAgilent 1100 Series Well-plate Sampler & Micro Well-plate Sampler. Reference Manual
Agilent 1100 Series Well-plate Sampler & Micro Well-plate Sampler Reference Manual s1 Notices Agilent Technologies, Inc. 2002 No part of this manual may be reproduced in any form or by any means (including
More informationYour Best Choice For Laboratory Consumables
Your Best Choice For Laboratory Consumables ISO9001:2008 Certificate No. 34730 Report No.01893 Registration No. 10035061 Wuxi NEST Biotechnology., LTD Headquarters Add: No 230, Xida Road, New District,
More informationAutoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:
Autoclave Safety Purpose: Sterilization refers to the complete killing of all living organisms, including spores. Common sterilization techniques include the application of wet heat, dry heat, chemicals,
More informationMultiple flasks. Easy to adapt. Stuart range of heating blocks
Heating Blocks The Stuart range of heating blocks have been developed in conjunction with DrySyn to provide the best possible solution for heating round bottom flasks. Combined with the Stuart range of
More informationBRIEFING 661.2 Plastic Packaging Systems for Pharmaceutical Use.
BRIEFING 661.2 Plastic Packaging Systems for Pharmaceutical Use. USP proposes the revision and development of a suite of plastic packaging system standards in the current issue of PF. General test chapter
More informationsyriq Glass Prefillable Syringes
syriq Glass Prefillable Syringes 2 SCHOTT is a leading international technology group in the areas of specialty glass and glass-ceramics. With more than 130 years of outstanding development, materials
More informationRevised 4-3-2012 EHS Biosafety. 1 Select appropriate containers/bags for autoclaving.
Requirements for Decontamination by Autoclaving Summary: Steam sterilization (autoclaving) is one of the most effective methods for decontaminating biohazardous material. Autoclaves use saturated steam
More informationSolids, Volatile Dissolved and Fixed Dissolved
, 8277 Solids, Volatile Dissolved and Fixed Dissolved Gravimetric Method 1 Scope and Application: For wastewater. 1 Adapted from Standard Methods for the Examination of Water and Wastewater DOC316.53.001206
More informationPRECISION LIQUID HANDLING
PRECISION LIQUID HANDLING Syringes & Valves R The Introduction Measure of Excellence HAMILTON Bonaduz HAMILTON Reno Total Customer Satisfaction Not just a slogan it s how we operate. A supplier can only
More informationArchived. Gloves should be changed frequently during the analysis.
Introduction Gloves and laboratory coats Small tools Specific clean-up and housekeeping procedures are used to help protect evidence samples from conditions and agents that might serve to destroy, deteriorate,
More informationLab Exercise 3: Media, incubation, and aseptic technique
Lab Exercise 3: Media, incubation, and aseptic technique Objectives 1. Compare the different types of media. 2. Describe the different formats of media, plate, tube etc. 3. Explain how to sterilize it,
More informationCorning Storage Bottles Selection and Use Guide
Corning Storage Bottles Selection and Use Guide Contents Glass Screw Cap Storage Bottles.......................... 2 Plastic Screw Cap Storage Bottles......................... 4 Caps and Accessories.....................................
More informationwww.sampling.com World Class Equipment worldwide Edition J
www.sampling.com World Class Equipment worldwide Edition J Welcome Welcome to the latest edition of our Range Brochure Firstly, we would like to thank you our customers for helping us create the new range
More informationHPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies
HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies Application Note Small Molecule Pharmaceuticals Authors Jignesh Shah, Tiantian Li, and Anil Sharma Agilent Technologies,
More informationBack to School Promotion Offers - consumable (Aug 2014)
Back to School Promotion Offers - consumable (Aug 2014) Valid till 30 th November, 2014 Beakers Beaker, Borosilicate glass, low form Code Cap. Price Promotional Price UR-C15720-0005 5ml HKD $7/pc HKD $63/
More informationWashing. Sterilising. Filling. Closing. Inspecting. Labelling
Washing. Sterilising. Filling. Closing. Inspecting. Labelling Washing Page 4/5 Sterilising Page 6/7 Filling Page 8/9, 10/11 Closing Page 8/9, 10/11 Inspecting Page 12/13 Labelling Page 14/15 Syringe processing
More informationORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
More information<788> PARTICULATE MATTER IN INJECTIONS
PARTICULATE MATTER IN INJECTIONS Particulate matter in injections and parenteral infusions consists of mobile undissolved particles, other than gas bubbles, unintentionally present in the solutions.
More informationA Guide to the Handling and Disposal of Medical Waste Contents
A Guide to the Handling and Disposal of Medical Waste Contents Introduction... 2 Definitions... 2 Medical waste... 2 Biological waste... 2 Solid Waste... 2 Types of Medical Waste... 3 Human Blood and Blood
More informationRooflight INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary
More informationEmpore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description
Technical Information Empore 96-Well Solid Phase Extraction Plates Instructions for Use Product Description Empore 96-Well Solid Phase Extraction Plates are designed for high throughput solid phase extraction
More informationSTANDARD OPERATING PROCEDURES Safe Autoclave Operations
Department of Environmental Health & Safety Biosafety & Biosecurity STANDARD OPERATING PROCEDURES Safe Autoclave Operations The purpose of this document is to provide standard operating procedures for
More informationOrganic Chemistry Calculations
Organic Chemistry Calculations There are three basic units for measurement in the organic laboratory mass, volume, and number, measured in moles. Most of the other types of measurements are combinations
More informationLiquid II Cell Culture Media Manufacturing Plant. Overview Facilities Water for Injection Sterile Environment Media Handling Cleanroom Interior
Liquid II Cell Culture Media Manufacturing Plant Overview Facilities Water for Injection Sterile Environment Media Handling Cleanroom Interior Overview History of BioConcept and Amimed BioConcept has close
More informationlaboratory glass bottles and screw caps
LABWARE SCHOTT DURAN E SCHOTT DURAN laboratory glass bottles and screw caps - Rely on the original! - SCHOTT DURAN laboratory glass bottles Fields of application and properties The outstanding properties
More informationACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)
ACETA.02-1 ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography) PRINCIPLE Isovaleraldehyde (IVA) and acetaldehyde are released from the syrup with the aid of dilute phosphoric acid and heat. The liberated
More informationFractional Distillation and Gas Chromatography
Fractional Distillation and Gas Chromatography Background Distillation The previous lab used distillation to separate a mixture of hexane and toluene based on a difference in boiling points. Hexane boils
More informationWaters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
More informationwww.fluidx.eu Sample Storage Product Range
www.fluidx.eu Sample Storage Product Range FluidX External Thread Sample Storage Tubes 4. 6. 3. 5. 1. External Double Tread Cap External Thread Maximises Sample Volume while minimising Height saving over
More informationTubing and Accessories
Section 7 Tubing and Accessories Inch Industrial Tubing................................FIT-7-2 Metric Industrial Tubing...............................FIT-7-3 Inch D.O.T. Tubing...................................FIT-7-3
More informationEnvironmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater
Document: AND Sol Env 08 2013 Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater Matrix specific sample preparation and testing methods for environmental waters
More informationDecontamination and Waste Management www.biosecurity.sandia.gov
Decontamination and Waste Management www.biosecurity.sandia.gov SAND No. 2006-3684C Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States
More informationClassic Immunoprecipitation
292PR 01 G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name Classic Immunoprecipitation Utilizes Protein A/G Agarose for Antibody Binding (Cat.
More informationBlood Tubes and Lancets 1-800-962-9888
Blood Tubes and Lancets 1-800-962-9888 1-800-962-9888. Table of Contents BLOOD COLLECTION MONOJECT Blood Collection Products Safety Lancet... 4 Lancet... 4 Corvac Integrated Serum Separator Tubes Red/Grey
More informationINSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles
INSTALLATION RECOMMENDATIONS Outdoor Rubber Tiles Prior to Installation: The Outdoor Rubber Tiles and accessory transition pieces intended for this installation have been shipped to you via a freight carrier
More informationIgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.
IgM ELISA For the quantitative determination of IgM in human serum and plasma For Research Use Only. Not For Use In Diagnostic Procedures. Please read carefully due to Critical Changes, e.g., Calibrator
More informationPaper Chromatography: Separation and Identification of Five Metal Cations
Paper Chromatography: Separation and Identification of Five Metal Cations Objectives Known and unknown solutions of the metal ions Ag +, Fe 3+, Co 2+, Cu 2+ and Hg 2+ will be analyzed using paper chromatography.
More informationReadyPrep Protein Extraction Kit (Soluble/Insoluble) Instruction Manual. Catalog #163-2085
ReadyPrep Protein Extraction Kit (Soluble/Insoluble) Instruction Manual Catalog #163-2085 For technical service, call your local Bio-Rad office, or in the US, call 1-800-4BIORAD (1-800-424-6723) Table
More informationThermo Scientific 2D Barcoded Storage Solutions Reference. Ideal choices for reliable, efficient sample processing and storage.
2D Barcoded Storage Solutions Reference Ideal choices for reliable, efficient sample processing and storage. and The Automation Partnership (TAP) Capit-All Capper/Decapper processes a rack of tubes in
More informationCL001-V Classic swivel USB drive with silver clip. Available in 5 colors: white, orange (021C), blue (286C), black and red (185C).
Page 1 Custom USB Drives Custom USB Drives Page 1 CL001-V Classic swivel USB drive with silver clip. Available in 5 colors: white, orange (021C), blue (286C), black and red (185C). CL001-S Classic swivel
More informationChemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography
Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample
More informationCell Culture Roller Bottles
CELLMASTER TM Cell Culture Roller Bottles The cultivation of cells as mass cultures has become increasingly important over the past few decades and has led to the further development of the quality and
More informationProtocol: HPLC (amino acids)
Page 1 of 6 1. Chemicals Composition M MW gram volume (ml) product code 0-pthaldialdehyde C 8H 6O 2 134.13 Sigma P0657 Perchloric acid HClO 4 3.5 100.46 Dilute 70% stock solution 1:1 with demi to obtain
More informationElastomeric Components for Pharmaceutical Applications - Actual Quality Trends - Claudia Petersen. -Senior Manager Biotechnology-
Elastomeric Components for Pharmaceutical Applications - Actual Quality Trends - Claudia Petersen -Senior Manager Biotechnology- 2005 by West Pharmaceutical Services, Inc., Lionville, PA All rights reserved.
More informationImplant Systems MAX LOGIC MONO. Today s name in tomorrow s implant technology
Implant Systems MAX LOGIC MONO Today s name in tomorrow s implant technology Implant Systems Etgar Medical Implant Systems brings to the market an entire spectrum of dental implant products based on its
More informationAgarose Gel Electrophoresis with Food Color- Teacher Guide
Page 1 of 7 Project Home Gateway to the Project Laboratory Activities What the Project can do in the classroom Biotechnology Resources Favorite resources online and in print Agarose Gel Electrophoresis
More informationSterile and Ready-to-fill Glass Containers with new Packaging and Connection Solutions
Sterile and Ready-to-fill Glass Containers with new Packaging and Connection Solutions 0. Summary The last 30 years have witnessed continuous updates and innovation in the pharmaceutical packaging and
More informationHEALTHCARE Single - Use Systems CONTRACT MANUFACTURING SOLUTIONS PARTNER
HEALTHCARE Single - Use Systems CONTRACT MANUFACTURING SOLUTIONS PARTNER ASI (A Part of Thermo Fisher Scientific) is dedicated to providing innovative and cost effective solutions to the Life Sciences
More informationIdentification of Arson Accelerants by Gas Chromatography
Identification of Arson Accelerants by Gas Chromatography Purpose Arson is an insidious crime that annually claims the lives of hundreds of Americans and costs billions of dollars. 1 Scientists and criminal
More informationLunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide
Lunette 2 Series Curved Fixed Frame Projection Screen User s Guide Important Safety and Warning Precautions Please follow these instructions carefully to ensure proper maintenance and safety with your
More informationSterilization methods and equipment Lab 1-2
Sterilization methods and equipment Lab 1-2 PHT 434 Sterilization Sterilization a process that by which all viable M.O are removed or destroyed, based on a probability function. Sterilization concept Sterilization
More informationANALYTICAL OUTSOURCING WHY SHOULD YOU OUTSOURCE?
ANALYTICAL OUTSOURCING WHY SHOULD YOU OUTSOURCE? The choice to outsource is a somewhat difficult decision, but it is one that can be both analytically and financially rewarding. By carefully considering
More informationSafety. matters. CryoMACS Products
Safety matters CryoMACS Products CryoMACS Freezing Bags The right step towards safe more cryopreservation safety in cryopreserv Overwrap bag protects both sample and freezing bag during cryopreservation.
More informationAnalysis of Various Vitamins in Multivitamin Tablets
High Performance Liquid Chromatography Analysis of Various Vitamins in Multivitamin Tablets Effective August 24, 2007, the US Food and Drug Administration (FDA) issued a regulation (21 CFR Part 111) that
More informationInstalling the Sno-free Standing Seam System for Metal Roofs
Installing the Sno-free Standing Seam System for Metal Roofs SFP SSP CLIP SSP STANDING SEAM SFP EXTRUSION SFP RAMP PANEL Step # 1 Mark the location and Install Extrusion Mark the area on the roof to receive
More informationCare and Handling of Rotors
Care and Handling of Rotors Today s Objectives Help you to use centrifuge systems safely Ensure maximum life of your investment Avoid unbudgeted lab expenses Maximize experiment integrity Table of Contents
More informationThe Anatomy of a Label
The Anatomy of a Label Three key elements make up a label: face stock, release liner, and adhesive. Face Stock: Face stock is the material of the label that carries the imprint. The print can be applied
More informationTransport and Mailing Systems
Transport and Mailing Systems For transportation of diagnostic samples and blood products The complete product range for mailing and transport requirements Safe and compliant with transportation guidelines
More informationUSB TRADING & STOCK PRICELIST
USB & PRICELIST Rotate Basic USB Rotate Basic USB 1Z41000 1Z41001 1Z41002 1Z41003 1Z41004 Black White Blue Red 1234 1Z41005 1Z41007 1Z41007 1Z41008 1Z41009 Bright Red Lime Orange Yellow 1Z41010 1Z41012
More informationEH&S. Sheet. Fact. Safe and Effective Use of Autoclaves. What are autoclaves? Factors for effective sterilization. Dry heat cycle - when to use
Please post or circulate Fact heet nvironment, ealth and afety Information for the Berkeley Campus No. 33 Revised 04/04/11 afe and ffective Use of Autoclaves Autoclaves are easy to use but can pose a safety
More informationSciTech, sro Praha Ceník Jour Research tisk 3.1.2000
Ceny bez DPH, balného a poštovného. Jour Research pricelist 08/99 Part Number Description cena CZK 0001-0737 Wash-Pro Upgrade Kit 7098,00 0001-5530 Gas Flow Meter 22932,00 0001-5531 Silicon Connection
More informationWard 29 guide to the safe preparation and administration of intravenous (IV) antibiotics at home
Ward 29 guide to the safe preparation and administration of intravenous (IV) antibiotics at home Contents Page Important contact numbers 1 General information on preparing and administering IV antibiotics
More information1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to 9.0 3. Nonvolatile TOC content < 1.0 ppm
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More information105 Adopted: 27.07.95
105 Adopted: 27.07.95 OECD GUIDELINE FOR THE TESTING OF CHEMICALS Adopted by the Council on 27 th July 1995 Water Solubility INTRODUCTION 1. This guideline is a revised version of the original Guideline
More informationKGI MEDICAL WASTE MANAGEMENT PLAN
1revised 2012 I. Facility Information KGI MEDICAL WASTE MANAGEMENT PLAN a. Contact Person: Barbara Erwin Director Research Operations/Chemical and Biological Laboratory Safety/Chair. 909-607-0160 i. Facility:
More informationThe Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port
APPLICATION NOTE Gas Chromatography/ Mass Spectrometry Authors: Andrew Tipler Sheila Eletto PerkinElmer, Inc. Shelton, CT The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory
More informationGMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS
PHARMACEUTICAL INSPECTION CONVENTION PHARMACEUTICAL INSPECTION CO-OPERATION SCHEME PI 032-2 8 January 2010 RECOMMENDATION GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE
More informationCorning Microplates Product Selection Guide. For Assays and Drug Discovery
Corning Microplates Product Selection Guide For Assays and Drug Discovery Introduction Corning Life Sciences is pleased to present our new Microplate Selection Guide. In this guide, you will find a selection
More information3M Dual Lock Reclosable Fastener
3 Dual Lock Reclosable Fasteners SJ3550CF (Type 250) SJ3551CF(Type 400) SJ3552CF(Type 170) Dual Lock Reclosable Fastener Black with a clear acrylic adhesive Product Information February, 2007 Product Description
More information