C-MAX The RF Technology Specialists
|
|
- Primrose Watts
- 7 years ago
- Views:
Transcription
1 Datasheet GW92 RC TABLE CLOCK MOVEMENT Distributed by The RF Technology Specialists SPECIFICATION OF GW92 RADIO-CONTROLLED CLOCK MOVEMENT 1 of 10
2 1. General description With this extremely accurate radio-controlled alarm movement you are in possession of the most advanced technology. The time of this radio-controlled alarm movement is set by the signals of the official time signal transmitter in Germany DCF 77, America WWVB, Japan JJY or Great Britain MSF. The clock sets itself automatically, including summer and wintertime 2. Starting the clock Insert one battery (AA 1.5 V, IEC LR6 alkaline) into battery-compartment respecting the correct polarity. You will hear a short Bip (0.5s) and the LED will be switched on for 2 seconds. Both hour and minute hands will move to the 12 o clock position. In good reception conditions the precise time will be set within 2 6 minutes. 3. Setting the alarm The desired alarm time is set manually, with setting knob. Turn the setting knob upwards. 4. Alarm On / Off Alarm ON Alarm OFF = slide the alarm switch upwards = slide the alarm switch downwards 5. LED-light / snooze a) LED light: Press multifunction bar, the LED light will be switched on for 5 seconds and will then switch off automatically. b) Snooze: When the alarm signal sounds, press multifunction bar briefly, the alarm signal will stop and sound again after 4 minutes. To stop alarm completely slide alarm switch downwards in Off position. 2 of 10
3 6. Manual time-setting By using Handset button, the time can be set manually. The clock should also be adjusted manually outside the cover area of the time signal. Press the button will move the hands step by step. By pressing and holding the button for a short period of time, the hands move faster. The movement will operate as a normal quartz clock until the signal of DCF 77 is again received. This is not valid for time zone setting (see point Nr. 7). 7. Time zone setting By pressing the multifunction bar, you will hear a Bip and the time will advance by one hour. This operation allows time setting to different time zones within the reception area of the DCF 77 transmitter (e.g. United Kingdom). In its new time zone, the clock will continue receiving the signal of DCF 77. (This time zone setting may be repeated as often as wished.) For WWVB, the U.S. signal, 4 time zone of P, C, E, M are able to selected with this multifunction bar setting. 8. Reset Take out the battery and then replace them into the battery compartment (hands will move to 12 o clock) and in good reception conditions the precise time will be set within 2 6 minutes as described under point NR Interference of signal reception As with any other radio receiver, the reception of the signal might be interfered. This can be caused by the location of the clock or by atmospheric influence. Reception can possibly be improved by repositioning the clock. Major influences in a normal household/ office environment are: curtains in aluminum electrical appliances which are not earthed computer, TV building in reinforce concrete or with metallic front 3 of 10
4 10. Low batteries If, when pressing the multifunction bar, the dial light is blinking or not lighting at all, the battery will have to be replaced within 1 2 days. Note: exhausted batteries have to be specially disposed off. Important notice: Empty batteries should be removed from the alarm clock. Avoid direct exposure to the sun. This alarm clock needs no adjustment or technical control. Modifications of the hand shafts are possible Only contacting from the front side possible The opto-sensor, for accurate detection, is integrated in the casing 11. Advantage of the movement Small, compact size Easy assembly Locked hand shaft position No handling necessary Integrated antenna Suitable for standard hands Automatic setting of winter and summer time. High speed time setting fully automatic Highest accuracy Time change (Summer/ Winter/ ST/ DST) fully automatic Automatic synchronization 12. The Characteristic of the movement Modifications of the hand shafts are possible Only contacting from the front side possible The opto-sensor, for accurate detection, is integrated in the casing 4 of 10
5 13. Working area/ field of activity - Voltage at R v = 250 Ω V - Current consumption per step by 2.2V R v = 250 Ω I = 4 ma Test circuit R1 250R 2,2V G M R=310 I - Pulse width 63 m sec - Temperature -5 C ± 55 C 14. Mechanical Data - Impulse torque at U min = 2.2 V at R v = 250 Ω - Torque, Minute shaft > 3 p mm Allowed force to set the hands - Hour hand Max. 3 kp - Minute hand Max. 3 kp - Alarm hand Max. 3 kp Alarm contact function - Chatter (Dynamic performance): the maximum allowed chatter must be in accordance to the IC data sheet specification. - Spring strength (F f ) 12 p < F f < 30 p - Lifetime of alarm contact > 3000 times - Test: base on 3000 switch trials, 100 hours, storing by 40 C, % relative humidity, 20 trials contact alarm activity with alarm plate. 5 of 10
6 15. Dimensions of the GW92 Gearbox 6 of 10
7 7 of 10
8 16. Environmental and transportation - The Movement must according to the test below and after 24 h recovering time be able to fulfill the specification. - Thermal conditions: - 20 C / 24hrs +60 C / 100hrs +70 C / 4 h, Clock complete. - Climate conditions: 90 95% rel. humidity by 40 C +/- 5 C, 1 month - Aging: According to specification WN , point 4 - Corrosion resistance: According to specification WN , Point 5 - Shock conditions: according to DIN Lifetime n5 years - The movement must show the full performance after the specified continuously run according to the above specification. - operation noise measurement by U n = 3V - operation noise of the movement / minute step < 38 db (A) - operation noise of the movement / fast mode < 45 db (A) - Measuring method sound measuring condition Measuring device: e.g. Company Bruel & Kjaer Impulse precision sound Level Meter 2204 with measuring micro, type 4145 in the set up A Filter; evaluation with impulse mode, the average of the 10 highest values will be used. The measurement is done under free field conditions according to DIN The Movement must be in the upright position (assembly position) the minute hands must be installed and the unit must be placed on a smooth underground. microphone 20 mm Distance for the measurement 20mm Smooth underground ( vibration free) 8 of 10
9 18. Test of the mirror assembly in the movement - Mechanical test - Movement blocked with the pin - mirror must be 100% visible - After the pin is removed and no power is connected the mirror must be 50% visible. - After the pin is removed, and 1,5V are connected to the coil ( the polarity have to be chosen that no step will be done) the mirror must be 100% visible. Dynamic test - 12 std. fast mode (around 45s) - Braun - test circuit built up At 3.4V with memory oscilloscope at the measurement point m sec 3,4 V 3,4 V 2,8 V Allowed interference < 0.6V level 0 V Optical sensor usable signal < 1V 9 of 10
10 19. Technical Data Indicated values are based on: Ambient temperature = -5 C +/- 55 C Voltage coil = V Function / Drive Reading Max. electrical time setting speed Two phase stepper motor Hours Minutes Forwards Single step setting to Quick Setting (24 Minute-steps/ Sec.) Working temperature range -60 C To + 70 C /C Voltage working range 2.2 to 3.4 V Coil resistance 250 Ohm Max. impulse current 4 ma Torque on the minute shaft > 3 pmm Max. weight of hand 3 g Max. unbalance of hand 0.05 mnm Dim 20. Disclaimer of Warranty Information furnished is believed to be accurate and reliable. However A. Haller GmbH & Co KG and the group assumes no respons ibility Neither for the consequences of use of such information nor for any infringement of patents or other rights of third parties, which may result from Its use. No license is granted by implication or otherwise under any patent or patent rights of A. Haller GmbH & Co KG or the C-Maxgroup. Specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied. A. Haller GmbH & Co KG and group products are not authorized for use as critical components in life support devices without express written approval of A. Haller GmbH & Co KG or the group. Note It is not given warranty that the declared circuits, devices, facilities, components, assembly groups or treatments included herein are free from legal claims of third parties. The declared data are serving only to description of product. They are not guaranteed properties as defined by law. The examples are given without obligation and cannot given rise to any liability. Reprinting this data sheet - or parts of it - is only allowed with a license of the publisher. A. Haller GmbH & Co KG and the group reserve the right to make changes on this specification without notice at any time. Andreas Haller Europe GmbH Components Co Ltd GmbH & Co KG Aspergerstr. 39 Unit 1801, Tower II, Enterprise Square Bahnhoftsr Heilbronn 9 Sheung Yuet Road, Kowloon Bay, St. Georgen Kowloon Bay, Kowloon H.K. Tel.: Tel.: Fax: Fax: contact@c-max-europe.de inquiry@c-max.com.hk Data sheets can also be retrieved from our Internet homepage: 10 of 10
Atomic Alarm Clock Instruction Manual
Atomic Alarm Clock Instruction Manual Introduction: Congratulations on purchasing the Atomic Alarm Clock with WWVB Radio controlled time, calendar, 12/24 hours display, time zone with US map, indoor temperature
More informationMEMO ALARM CLOCK Operating Manual
MEMO ALARM CLOCK Operating Manual INTRODUCTION Congratulations on purchasing this state-of-the-art Alarm clock with radio controlled time. The operation of this product is simple and straightforward and
More informationRadio-Controlled Projection Clock with Indoor Temperature
Item 972483 Radio-Controlled Projection Clock with Indoor Temperature Owner s Manual Thank you for purchasing the new generation of projection clock. Designed and engineered with the state-of-art technology
More informationRADIO CONTROLLED DIGITAL CLOCK MODELS 88905 / 88906
RADIO CONTROLLED DIGITAL CLOCK MODELS 88905 / 88906 QUICK SETUP GUIDE IMPORTANT! INSTALL BATTERIES IN THE OUTDOOR TRANSMITTER BEFORE INSTALLING BATTERIES IN THE RADIO-CONTROLLED CLOCK. ALKALINE BATTERIES
More informationTime. Choose a location 6 feet or more from electronics such as cordless phones, wireless gaming systems, televisions,
Model: 404-1220 Instruction Manual DC: 050614 20 Atomic Wall Clock Mountain Central DST Indicator Pacific Eastern Manual Set Button Battery Compartment 1- C Alkaline Get Started Step 1: Insert 1 fresh
More informationGB Instruction Manual. www.quantys.de
GB Instruction Manual www.quantys.de GB Instruction manual Solar RADIO-CONTROLLED ALARM CLOCK With analogue alarm time setting Safety instructions - Swallowing batteries can be life-threatening. Therefore,
More informationWIRELESS WEATHER STATION Model 81690 USER'S INSTRUCTIONS
WIRELESS WEATHER STATION Model 81690 USER'S INSTRUCTIONS The multifunctional weather station is equipped with many functions providing thorough weather information to you. The receiver unit has a clear,
More informationAtomic Projection Alarm with Indoor and Outdoor Temperature
Model: WS-5220U-IT Instruction Manual DC: 082415 Atomic Projection Alarm with Indoor and Outdoor Temperature SNOOZE button Time, Alarm + WWVB Icon Projection arm Indoor Temp., Outdoor Temp. Battery Compartment
More informationModel: 616-146v2 Quick Setup Guide DC: 071015 Atomic Projection Alarm with Indoor and Outdoor Temperature
Model: 616-146v2 Quick Setup Guide DC: 071015 Atomic Projection Alarm with Indoor and Outdoor Temperature Snooze/Backlight BUTTONS Time, Alarm with Snooze, & Calendar Projection Arm Rotates 180 Indoor/Outdoor
More informationThe Weather Station. Hanging Hole. LCD Display Battery Cover. Function Keys. Detachable Stand
WIRELESS 433 MHz WEATHER STATION Instructions Manual INTRODUCTION: Congratulations on purchasing this Weather Station with wireless 433 MHz transmission of outdoor temperature and display of indoor temperature
More informationWEATHER STATION Instruction Manual Cat. No. 35.1115.IT
WEATHER STATION Instruction Manual Cat. No. 35.1115.IT Thank you for choosing this wireless weather station from TFA. BEFORE YOU USE IT Please be sure to read the instruction manual carefully. This information
More informationLCD Display. Function keys. Stand. Adapter socket
433 MHz RADIO CONTROLLED PROJECTION ALARM CLOCK Instructions manual INTRODUCTION: Congratulations on purchasing this innovative 433MHz Projection alarm clock which displays indoor temperature and humidity
More informationJumbo Atomic Clock. Model 86931 With Indoor Temperature Instruction Manual THE SKYSCAN ATOMIC CLOCK
Jumbo Atomic Clock Model 86931 With Indoor Temperature Instruction Manual THE SKYSCAN ATOMIC CLOCK With the SkyScan Atomic Clock, you have the most accurate timepiece within the continent. It can receive
More informationTalking Atomic Alarm Clock Instructions
1 Talking Atomic Alarm Clock Instructions S1 (Talking+Snooze+Back Light) S2 (Alarm Time + Alarm Hour) S4 (Alarm Volume + OFF) S3 (Alarm ON/OFF + Alarm Minute) S5 (Wave, Manual Signal Reception) S8 (DST
More informationControl Location. Replacing Battery
Functions - Normal Time with PM Indicator - 12/24 hour selectable - Dual Alarm, Snooze, Sleep Timer Green LED Backlight display - Month and Date Display - Thermometer (32oF - 122-F) - AM/FM Radio Receiver
More informationRF Projection Barometer With Remote Thermo Sensor
RF Projection Barometer With Remote Thermo Sensor Model No.: BAR338P (UK VERSION BAR338PU) User s Manual MAIN UNIT CONTROLS GB INTRODUCTION Congratulations on your purchasing the BAR338P RF Projection
More informationSolar Weather Station Model: BAR806 / BAR806A
Solar Weather Station Model: BAR806 / BAR806A EN CONTENTS USER MANUAL Overview... 2 Front view... 2 Back view... 3 Remote sensor... 3 Getting started... 3 Solar panel... 3 Insert batteries... 4 Remote
More informationReizen Atomic Talking Analog Alarm Clock Item #706810. Instruction Manual
Reizen Atomic Talking Analog Alarm Clock Item #706810 Instruction Manual S1 (Talking + Snooze + Lamp) S2 (Alarm Hour) S4 (Alarm Volume + Off) S3 (Alarm Minute) S7 (Time Zone: P,M,C,E) S5 (Wave) S8 (DST
More informationModel: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION
Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION FRONT VIEW SENSOR TX141TH-Bv2 LED TX Sensor Battery Cover Sensor Battery Compartment 2 AA Buttons Battery Compartment 3 AAA BACK VIEW Battery
More informationReizen Atomic Talking Analog Alarm Clock Item #706810. Instruction Manual
Reizen Atomic Talking Analog Alarm Clock Item #706810 Instruction Manual 1 Instruction Manual of Atomic Analog Talking Clock (Single-Band) S2 (Alarm Hour) S1 (Talking+Snooze+Lamp) S4 (Alarm Volume+Off)
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationAtomic Alarm Clock model 13131W2
Instruction Manual Atomic Alarm Clock model 13131W2 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Clock Setup... 4 Atomic Clock... 5 Set
More informationPlease read the operating instructions carefully to familiarize yourself with the features and modes of operation before using the instrument.
WS 6750 weather station user manual Please read the operating instructions carefully to familiarize yourself with the features and modes of operation before using the instrument. Technical Details Six
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationGet Support: www.lacrossetechnology.com/308-146
Model: 308-146/308-146W Instruction Manual The Wireless Color Forecast Station features atomic time, weather forecast, indoor and outdoor temperature/humidity as well as heat index and dew point, on a
More informationATOMIC CLOCK WITH MOON PHASE. MODEL 86730 Instruction Manual
ATOMIC CLOCK WITH MOON PHASE MODEL 86730 Instruction Manual FEATURES: WWVB Radio controlled time with manual time setting 12/24 hour time display Time display: hour, minute, second Alarm setting with snooze
More informationHAZUBA. HAZUBA AG Rainstrasse 17 4528 Zuchwil T 032 685 88 88 F 032 685 88 89 info@hazuba.ch 06/14
06/14 NEW BNC 002 BK 29.- CHF This Braun travel alarm clock measures 56mm x 56mm x 31mm and is available in two colours. It has an easy to read dial layout, crescendo alarm and a quiet German precision
More informationIN-OUT Thermometer with Cable Free Sensor and Clock
IN-OUT Thermometer with Cable Free Sensor and Clock MODEL: RAR232 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RAR232 In-Out Thermometer with 433MHz cable free sensor and calendar
More informationQFP910. Water detector. Building Technologies. CE1N2732en. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationWIRELESS MULTI-ZONE DIGITAL WEATHER CENTER. Model No. 91905 User s Manual
WIRELESS MULTI-ZONE DIGITAL WEATHER CENTER Model No. 91905 User s Manual BASE STATION REMOTE SENSOR FEATURES AND SPECIFICATIONS BASE STATION Indoor / wireless outdoor temperature, C / F selectable Indoor
More informationWIRELESS FORECAST STATION
Model: 308-1451 Instruction Manual DC: 072915 WIRELESS FORECAST STATION Table of Contents INITIAL SETUP... 2 LCD FFEATURES... 3 BUTTONS... 3 SET TIME, DATE, ETC.... 4 BACKLIGHT... 6 CITY SELECTION-SUNRISE/SUNSET
More informationAdding Heart to Your Technology
RMCM-01 Heart Rate Receiver Component Product code #: 39025074 KEY FEATURES High Filtering Unit Designed to work well on constant noise fields SMD component: To be installed as a standard component to
More informationLUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
More informationPluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
More informationWIRELESS 868 MHz WEATHER STATION Instruction Manual
WIRELESS 868 MHz WEATHER STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this fancy Weather Station with wireless 868MHz transmission of outdoor temperature and display of indoor
More informationREMOTE TERMOMETER TE 219 LED USER MANUAL
INTRODUCTION REMOTE TERMOMETER TE 219 LED USER MANUAL Thank you for purchasing this unit with indoor thermometer, wireless thermometer sensor and radiocontrolled clock. This device is also equipped with
More informationAtomic Projection Alarm Clock model 13021
Instruction Manual Atomic Projection Alarm Clock model 13021 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Clock Setup... 5 Atomic Clock...
More informationWIRELESS 433 MHz WEATHER CLOCK Instruction Manual
WIRELESS 433 MHz WEATHER CLOCK Instruction Manual INTRODUCTION: Congratulations on purchasing this fancy Weather clock with wireless 433MHz transmission of outdoor temperature and display of indoor temperature
More informationWIRELESS 433 MHz TEMPERATURE STATION Instruction Manual Cat. No. 30.3015
WIRELESS 433 MHz TEMPERATURE STATION Instruction Manual Cat. No. 30.3015 Thank you for choosing this wireless temperature station from TFA. BEFORE YOU USE IT Please be sure to read the instruction manual
More informationWIRELESS 868 MHz WEATHER CLOCK Instruction Manual
WIRELESS 868 MHz WEATHER CLOCK Instruction Manual INTRODUCTION: Congratulations on purchasing this fancy Weather Clock with wireless 868MHz transmission of outdoor temperature and display of indoor temperature
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationStove Guard Kit User Manual
Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent
More informationQFP910. Water detector. Building Technologies. CE1N2732en 2016-03-01. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
More informationATOMIC CLOCK WITH OUTDOOR WIRELESS TEMPERATURE
LCD1 display LCD2 display ATOMIC CLOCK WITH OUTDOOR WIRELESS TEMPERATURE INTRODUCTION: Congratulations on purchasing this state-of-the-art Skyscan Atomic Clock as an example of superior design and engineering.
More informationWEATHER STATION Instruction Manual Cat. No. 35.1111.IT
WEATHER STATION Instruction Manual Cat. No. 35.1111.IT Thank you for choosing this wireless weather station from TFA. BEFORE YOU USE IT Please be sure to read the instruction manual carefully. This information
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationOPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3
2 Phase Stepping Motor Driver 2M542 OPEATING MANUAL Table of contents Introduction page 2 Specifications page 2 Timing chart page 3 Setting page 4 Current set page 4 educe current function page 4 Micro
More informationDescription. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
More informationRDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
More informationCM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?
WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?...an explanation for householders A programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set On and Off time periods
More information1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.
1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter
More informationIntelli-Time Alarm Clock model 13027
Instruction Manual Intelli-Time Alarm Clock model 13027 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Clock Setup... 4 Intelli-Time Clock...
More informationTOUCH SCREEN WEATHER STATION MODEL WS-3500. Operation Manual
TOUCH SCREEN WEATHER STATION MODEL WS-3500 Operation Manual 28 Table of Contents 1... General 2... Important Touch Screen Operating Notes generally applicable 3... Putting into Operation 3.1... Wiring
More informationWireless Keyboard with Touchpad
Wireless Keyboard with Touchpad Quick Installation Guide 86266 Features Worldwide 2.4G wireless program Meet the ergonomic shape design concept Chocolate keycap design, flexible operation, easy to clean
More informationUser's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
More informationClear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationUser manual BETSO WTCS. 16 channel wireless digital TC slate. 1 Copyright BETSO ELECTRONICS Ltd.
16 channel wireless digital TC slate 1 Copyright BETSO ELECTRONICS Ltd. Contents 1. Product description...3 2. Top features...3 3. Control elements...4 4. Insertion of batteries / accumulators...6 5. External
More informationAAV003-10E Current Sensor
Datasheet AAV003-10E Current Sensor Key Features For Low Current Detection On-Chip Current Strap for Precise Operation 80 ma to +80 ma Linear Range Sensitivity up to 2 mv/ma AC or DC Measurement Ultraminiature
More informationSILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES
FTR-K1 SERIES SILENT POWER RELAY 1 POLE - 78A/120A Inrush Current Type FTR-H3 Series FEATURES Pin compatible with widely used VS and FTR-H1 series power relays Silent relay with patented unique U-shape
More informationINTEGRATED CIRCUITS. NE558 Quad timer. Product data Supersedes data of 2001 Aug 03. 2003 Feb 14
INTEGRATED CIRCUITS Supersedes data of 2001 Aug 03 2003 Feb 14 DESCRIPTION The Quad Timers are monolithic timing devices which can be used to produce four independent timing functions. The output sinks
More informationDIGITAL ALARM CLOCK RADIO
DIGITAL ALARM CLOCK RADIO INSTRUCTION MANUAL For information and support, www.lenco.eu CR3302 LENCO ENG FM ONLY IM 98 x1 1 11/5/2009 9:14:35 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN WARNINGS ATTENTION
More informationCOMBIMASS. Technical Data COMBIMASS eco-bio +
COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments
More informationPMEG1020EA. 1. Product profile. 2 A ultra low V F MEGA Schottky barrier rectifier. 1.1 General description. 1.2 Features. 1.
Rev. 04 30 December 2008 Product data sheet 1. Product profile 1.1 General description Planar Maximum Efficiency General Application (MEGA) Schottky barrier rectifier with an integrated guard ring for
More information308-146/308-146W FAQS
308-146/308-146W FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader
More information1. Introduction. 2. Components. 3. Optical Specifications. 4. Electric Specifications. 5. Dimension. 6. Operating Environment. 7.
SPECIFICATIONS Super Model: XHS-220S1 Class Solar Simulator 1. Introduction 2. Components 3. Optical Specifications 4. Electric Specifications 5. Dimension 6. Operating Environment 7. Warranty SAN-EI ELECTRIC
More information162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL
162 CB CABLE TRACER Filter Probe & Tone Generator INSTRUCTION MANUAL INDEX PAGE 1. INTRODUCTION... 1 2. FILTER PROBE... 1-3 3. TONE GENERATOR... 3-6 4. SPECIFICATION... 7-8 5. MAINTENANCE... 8 1. INTRODUCTION
More informationJUNGHANS MEGA ALARM-CHRONO W 615.33
JUNGHANS MEGA ALARM-CHRONO W 615.33 reset set + mode set GB Contents Page 1. Wireless technology 52 53 2. Readiness for use 54 55 3. Automatic time synchronisation 56 4. Functions 57 4.1. Base mode 58
More informationJ TB/TW Temperature limiter, temperature monitor
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
More informationSonic Boom Travel & Bed side Alarm Clock with Bed Shaker Model SB200ss-v3
Sonic Boom Travel & Bed side Alarm Clock with Bed Shaker Model SB200ss-v3 IMPORTANT Please read these instructions carefully before use and retain for future reference. See operating instructions on back.
More informationVHF COMMUNICATION TRANSCEIVER
ATR-500 VHF COMMUNICATION TRANSCEIVER ON OFF OPERATION MANUAL Manual Number 01.125.010.08 REVISION 1.3, Jan 20. 2005 from S/N 00301 04 Contents 1 SECTION 1 GENERAL INFORMATION...3 1.1 INTRODUCTION...3
More informationWITURA CORPORATION SDN BHD
WT 1010SA Stand Alone GSM Alarm System User Manual and Installation Instructions Version: 1.2 Updated: 4 JAN 2012 WITURA CORPORATION SDN BHD Stand Alone GSM Alarm System Instruction Manual 1 Introduction:
More informationVOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1
More informationPortable Bluetooth Speaker. Quick Start Guide. Model: BTS201
Portable Bluetooth Speaker Quick Start Guide Model: BTS201 Disclaimer All the information, design and specifications contained in this manual were correct at the time of publication. However, as the product
More informationRELAYS Solar Energy Systems
RELAYS Solar Energy Systems FUJITSU COMPONENTS CONTENTS Fujitsu relays for solar applications DC voltage versions - AC voltage versions - Latching versions RELAY PRODUCT LINE UP - SOLAR ENERGY SYSTEMS
More informationLB Sky Global. 92 Lobachevskogo St, Bld 92, Office 5, Moscow, Russia 119454 Tel/Fax 7(495)229-39-78, E-mail: office@grouplb.com, Site: www.grouplb.
Perimeter security system T-REX Moscow, 2011 Table of content 1. Introduction... 3 2. Main features of the T-REX system... 3 3. Structure of the system... 5 4. SL-6000 system sensors... 6 5. Signal processing
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationModel SBB500SS-v3. Sonic Boom Alarm Clock & Bed Shaker OPERATION INSTRUCTIONS
Model SBB500SS-v3 Sonic Boom Alarm Clock & Bed Shaker OPERATION INSTRUCTIONS IMPORTANT Please read these instructions carefully before use and retain for future reference. See operating instructions on
More informationWS-9005TWC 915MHz WIRELESS RAIN GAUGE INSTRUCTION MANUAL
WS-9005TWC 915MHz WIRELESS RAIN GAUGE INSTRUCTION MANUAL CONTENTS 03 introduction 03 features 04 setting up 06 function keys 06 operations 07 mounting 08 maintenance 09 specifications 09 liability disclaimer
More informationManual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
More informationOperating Manual Remote Cost Control Monitor
Operating Manual Remote Cost Control Monitor INTRODUCTION: Congratulations on purchasing the Remote Cost Control. This is a state-of-the-art power monitoring socket that is highly accurate and easy to
More informationFiber Optics. Integrated Photo Detector Receiver for Plastic Fiber Plastic Connector Housing SFH551/1-1 SFH551/1-1V
Fiber Optics Integrated Photo Detector Receiver for Plastic Fiber Plastic Connector Housing SFH551/1-1 Features Bipolar IC with open-collector output Digital output, TTL compatible Sensitive in visible
More informationBUSINESS. Elektronisches Türschloss. Installation and User Manual. www.burg-waechter.de. Ingeniously safe. Ingeniously simple.
Elektronisches Türschloss BUSINESS Set 5011 PINCODE Set 5012 FINGERSCAN Set 5013 E-KEY Ingeniously safe. Ingeniously simple. BA/MA TSE Set 5000 dp/fsc 04/2012 Installation and User Manual BURG-WÄCHTER
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationEFC 3600. Frequency converters
2 Bosch Rexroth AG Electric Drives and Controls Documentation Compact and complete: space saving side-by-side assembly, plug-in I/O terminals, with brake chopper and mains filter for ultra-simple installation
More informationAtomic Dual Alarm Clock models 13022 / 13035
Instruction Manual Atomic Dual Alarm Clock models 13022 / 13035 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits: Sensor... 2 Features & Benefits:
More informationWeather Station TE 529EL USER MANUAL
Weather Station TE 529EL USER MANUAL INTRODUCTION : Congratulations on your purchase of the weather station TE529EL with wireless sensor and radio controlled clock. The basic package comes with a main
More informationINSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE
INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE Ver. 2.0 AND SAVE THIS MANUAL FOR FUTURE REFERENCE Table of Contents Unpacking... 3 About the CCRadio-EP... 4 Quick Start Guide...
More informationTS-300-MSF TS-300 INSTALLATION AND CONFIGURATION MANUAL
TS-300 INSTALLATION AND CONFIGURATION MANUAL CONTENTS Contents... 2 Introduction... 3 Features... 3 What should be shipped... 4 Standard Parts... 4 Optional Parts... 4 Technical Specification... 5 System
More informationSeries 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
More informationEnglish AUTOMATION SYSTEMS FOR SLIDING GATES. Operating and installation instructions SLIDE SERIES
English AUTOMATION SYSTEMS FOR SLIDING GATES Operating and installation instructions SLIDE SERIES v.0 Rev /202 INDEX ) General Safety Regulations... pág. 0 2) Description... pág. 02 3) Technical Specifications...
More informationOperating instructions for built-in electronic timers with Day and Week programms. Series 884
Operating instructions for built-in electronic timers with Day and Week programms Series 884 Attention: This operating manual is destined for our OEM customers and is intended as a basis for the instruction
More informationSmoke exhaust systems
1 Fire zone, e.g. hall 2 Smoke exhaust zone, separated by smoke curtains Natural and mechanical smoke extraction General information 3 Natural smoke and heat exhaust vent 4 Air inlet opening or wake max.
More informationTechnical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
More informationRadio BMR100 INSTRUCTION MANUAL. ENGLISH (Original instructions)
ENGLISH (Original instructions) INSTRUCTION MANUAL Radio BMR00 WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Symbols The following show
More informationDigital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
More informationDrayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
More informationTLI4946. Datasheet TLI4946K, TLI4946-2K, TLI4946-2L. Sense and Control. May 2009
May 2009 TLI4946 High Precision Hall Effect Latches for Industrial and Consumer Applications TLI4946K, TLI4946-2K, TLI4946-2L Datasheet Rev. 1.0 Sense and Control Edition 2009-05-04 Published by Infineon
More information