EMC MANAGEMENT INTEGRATION FOR MICROSOFT PRIVATE CLOUD

Size: px
Start display at page:

Download "EMC MANAGEMENT INTEGRATION FOR MICROSOFT PRIVATE CLOUD"

Transcription

1 White Paper EMC MANAGEMENT INTEGRATION FOR MICROSOFT PRIVATE CLOUD (ESI) for Windows Suite, Microsoft System Center 2012 Application to infrastructure management and monitoring Optimized storage for elastic infrastructures Automated storage provisioning EMC Solutions Group Abstract This paper provides reference architecture for a Microsoft private cloud solution hosting SharePoint, Exchange, and SQL Server. The solution uses Microsoft System Center 2012 with ESI for Windows Suite to manage an infrastructure of multiple hypervisors (Microsoft Hyper-V, VMware ESXi ) and multiple storage arrays (EMC VNX, EMC Symmetrix VMAX ). February 2013

2 Copyright 2013 EMC Corporation. All Rights Reserved. EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com. All trademarks used herein are the property of their respective owners. Part Number H

3 Table of contents Executive summary... 7 Business case... 7 Solution overview... 7 Key results... 7 Introduction... 8 Purpose... 8 Scope... 8 Audience... 8 Terminology... 8 Technology overview Overview EMC VNX EMC VMAX 10K EMC FAST VP EMC Unisphere ESI for Windows Suite ESI for Windows ESI Management Packs for SCOM ESI PowerShell Toolkit EMC SMI-S Provider EMC PowerPath/VE Microsoft System Center SCVMM SCO SCOM SCOM MPs Multi-hypervisor environments Microsoft Windows Server 2012 Hyper-V VMware ESXi Solution architecture and configuration Overview Physical environment Hardware resources Software resources Workload profile

4 Storage layout EMC VNX EMC VMAX 10K Storage configuration VNX5700 storage allocation EMC FAST VP VMAX 10K storage allocation System management design and configuration Overview EMC components Interoperability with Microsoft components Monitor and report ESI Management Packs Storage monitoring with ESI Management Packs Application monitoring with SCOM MPs SQL Server SharePoint Exchange Reporting Host utilization Chargeback Cloud management Hyper-V management ESXi management Storage management Components EMC storage discovery Storage pool management LUN creation with SCVMM Workflow management SCO preparation steps Runbook Designer Step 1: Virtual machine creation and deployment Step 2: Storage provisioning Application design and configuration Overview Co-location of SQL Server and SharePoint volumes SQL Server Design and requirements Configuration

5 SharePoint Design Configuration SharePoint 2010 user requirements Exchange Exchange Server 2010 user requirements Exchange Server 2010 building-block design Exchange Server 2010 DAG design ESXi virtual machine design for Exchange Server Hyper-V Cluster ESXi cluster Validation Overview Test methodology Functional testing of System Center 2012 with EMC components SCOM 2012 SP1 with ESI Management Pack testing SCO 2012 SP1 with ESI PowerShell EMC VNX in-tier rebalance functionality Application performance across the environment SQL Server SharePoint Microsoft Exchange Load Generator Test results SCOM test and result Test 1: Remove disk to validate warning by SCOM monitoring view Test 2: Reboot VNX SP to validate warning in SCOM Test 3: Power off host server to validate warning in SCOM SCO test for creation of VM with automatic provisioning of storage EMC VNX rebalance functional test SQL Server results SharePoint 2010 results Storage pool utilization results LUN allocation results Co-location of SQL Server and SharePoint volumes on VNX Exchange Server 2010 results on VMAX 10K Conclusion Summary Findings

6 References White papers Product documentation Other resources

7 Executive summary Business case Organizations are increasingly looking to transform to a fully virtualized cloud infrastructure to both improve their service delivery and build a foundation to deliver IT as a service. This journey can be both daunting and confusing because administrators face the challenge of managing the wide range of ever-changing technologies across the modern data center. EMC can help guide organizations along this path, taking you step by step to your cloud and making it simpler to manage and more efficient to operate. A typical scenario is an organization running a Microsoft Windows environment that wants to adopt or already has adopted both Microsoft Hyper-V and VMware hypervisor platforms, along with having a number of storage arrays across its data centers. Managing such a multi-hypervisor, multi-array architecture is now simplified through the close integration of EMC Storage Integrator (ESI) for Windows Suite with Microsoft System Center 2012 Service Pack (SP) 1. The integration of these EMC and Microsoft products provides IT departments with a centralized platform to manage the application and storage infrastructure for the whole data center. Administrators can now take advantage of ESI for Windows Suite to manage, monitor, and automatically deploy EMC storage, along with the EMC Fully Automated Storage Tiering (FAST ) suite of technologies for intelligent storage self-optimization, for both the EMC VNX and EMC VMAX series arrays. Solution overview Key results This solution showcases a mixed Microsoft application workload (Microsoft Exchange 2010, Microsoft SharePoint 2010, and Microsoft SQL Server 2012), hosted on Windows Server 2012 Hyper-V and VMware ESXi clusters, to provide a multihypervisor environment found in today s corporate infrastructures. The environment is managed by Microsoft System Center 2012 SP1. The key findings of this solution are as follows: The ESI Management Packs for System Center Operations Manager (SCOM) provide the ability for SCOM 2012 SP1 to monitor the health and performance of EMC storage systems. The EMC SMI-S Provider allows System Center Virtual Machine Manager (SCVMM) 2012 SP1 to easily manage and provision EMC storage. ESI PowerShell allows automated provisioning and allocation of EMC storage with System Center Orchestrator (SCO) 2012 SP1. SCVMM 2012 SP1 provides simplified and centralized management of both ESXi and Hyper-V virtualization platforms. The new VNX feature of automatic in-tier rebalance, following storage-pool tier expansion, balances disk utilization. FAST VP policies allow co-location of multiple workloads (such as SQL Server and SharePoint) in the same storage pool, which simplifies storage design without compromising performance. 7

8 Introduction Purpose Scope The objective of this solution is to demonstrate EMC s integration with Microsoft System Center 2012 SP1, which allows support for Windows Server 2012 for the management of a Microsoft private cloud environment. The solution leverages System Center modules through ESI and SMI-S, using ESI Management Packs for SCOM, for example. SCVMM in System Center 2012 SP1 introduces a number of new changes for storage provider and automation support. The scope of this solution is to test and validate the management of a Microsoft private cloud infrastructure leveraging System Center 2012 SP1 and highlight the integration with EMC storage through SMI-S and ESI for Windows Suite. The following System Center 2012 SP1 components are validated: Virtual Machine Manager Orchestrator Operations Manager The solution demonstrates EMC s integration with System Center 2012 SP1 to: Manage EMC infrastructure using SCVMM and SCO Monitor EMC infrastructure using SCOM and SCOM MPs The solution also validates the support for Windows Server 2012 with Hyper-V with the EMC VNX and VMAX series storage arrays. Audience Terminology This white paper is intended for EMC employees, partners, and customers, including IT planners, storage architects, application administrators, and EMC field personnel who are tasked with deploying such a solution in a customer environment. It is assumed that the reader is familiar with the various components of the solution. Table 1 lists the terminology used in this solution paper. Table 1. Terminology Term BDM cmdlets DAG ESI FAST VP Flash Full name/definition Background Database Maintenance command-lets Database availability group EMC Storage Integrator Fully Automated Storage Tiering for Virtual Pools, which provides automatic storage tiering at the sub-lun level Flash drive technology 8

9 Term IOPS LoadGen LUN OLTP RAID SAS SCO SCOM SCOM MPs SCVMM SMI-S WFE Full name/definition Input/output operations per second; a measure of disk performance in terms of I/O command-processing throughput per second A simulation tool to measure the impact of MAPI, OWA, ActiveSync, IMAP, POP, and SMTP clients on Exchange servers Logical unit number; an identifier used to describe and identify logical storage objects of a storage subsystem Online transaction processing (such as a workload from a trading or banking application) Redundant Array of Independent/Inexpensive Disks Serial Attached SCSI System Center Orchestrator System Center Operations Manager System Center Operations Manager Management Packs System Center Virtual Machine Manager Storage Management Initiative - Specification Web Front End 9

10 Technology overview Overview The following components are used in this solution: EMC VNX5700 EMC VMAX 10K EMC FAST VP EMC Unisphere ESI 2.1 for Windows Suite EMC SMI-S Provider EMC PowerPath /VE Microsoft System Center 2012 SP1 SCVMM 2012 SP1 SCO 2012 SP1 SCOM 2012 SP1 SCOM MPs Multi-hypervisor environments Microsoft Windows Hyper-V Server 2012 VMware ESXi EMC VNX5700 EMC VMAX 10K EMC VNX5700 is a high-end, enterprise storage array comprising a system bay that includes a storage-processor enclosure and two storage processors, with disk-array enclosures, and separate storage bays that can scale up to 500 disk drives. VNX5700 arrays support multiple drive technologies, including Flash, Serial Attached SCSI (SAS), Near-Line SAS (NL-SAS) drives, and the full range of RAID types. The VNX series is powered by Intel Xeon processors, for intelligent storage that automatically and efficiently scales in performance while ensuring data integrity, security, and 24/7 uptime for mission-critical environments. EMC Symmetrix VMAX 10K is a new enterprise storage platform built to provide customers with unmatched, enterprise-level reliability, availability, and serviceability. The Symmetrix VMAX 10K leverages the EMC Virtual Matrix Architecture and is a 100 percent virtually provisioned system. EMC Virtual Provisioning gives a host, application, or file system the view that it has more storage than is physically provided. Physical storage is allocated only when the data is written, rather than when the application is initially configured. This eliminates manual calculations and also can reduce power and cooling costs by decreasing the amount of idle storage capacity in the array. Symmetrix VMAX 10K is designed for easy installation, setup, and use. It is delivered preconfigured, and installation takes less than four hours. The VMAX 10K is an ideal entry into a storage infrastructure based on Symmetrix systems. 10

11 EMC FAST VP EMC FAST VP is available in both the VNX and VMAX series storage arrays. Both implementations, although they work slightly differently, allow data to be tiered automatically in pools made up of more than one drive type and more than one RAID type between tiers. Tiered storage creates separate domains within the pool, based on performance capabilities of devices within the pool. The FAST VP software algorithmically promotes and demotes user data between the tiers based on data access patterns. This ensures that the most frequently accessed data resides on the fastest storage devices, and infrequently accessed data resides on more economical and high-capacity bulk storage. EMC Unisphere ESI for Windows Suite EMC Unisphere makes it easy to manage VNX and VMAX systems from anywhere with a simple, integrated user interface for distributed storage environments. The Unisphere dashboard provides a single screen for at-a-glance management and reporting. It enables administrators to gain instant and actionable knowledge about the environment. ESI for Windows Suite is a set of tools for Microsoft Windows and Microsoft applications administrators. The suite includes ESI for Windows, ESI Management Packs for SCOM, and ESI PowerShell Toolkit (PSToolkit). ESI for Windows ESI for Windows provides the ability to view, provision, monitor, and manage block and file storage for Microsoft Windows and Microsoft SharePoint. ESI supports the EMC Symmetrix VMAX series, EMC VNX and VNXe series, and CLARiiON CX fourthgeneration (CX4) series of storage arrays. ESI also supports storage provisioning and discovery for Windows virtual machines running on Microsoft Hyper-V, Citrix XenServer, and VMware vsphere. ESI Management Packs for SCOM ESI Management Packs for SCOM enable storage infrastructure management in a single user interface. With the SCOM integration, Windows administrators have the ability to discover storage assets, map physical and logical objects, and manage alerts and roll-up health states, with configurable parameter thresholds. Platforms supported are VMAX series and VNX series for both block and file. ESI PowerShell Toolkit ESI PSToolkit is a powerful utility designed for administrators and users of Windows to assist in storage system management. PSToolkit cmdlets enable storage system administrators to obtain storage system information; create and delete storage pools, storage groups, and storage volumes; and map and mask the pools, groups, and volumes to available host servers. This toolkit enables administrators to efficiently create automated scripts that help in the dynamic creation and deletion of virtual machines on an as-needed basis. EMC SMI-S Provider EMC SMI-S Provider V4.4 supports the Storage Networking Industry Association (SNIA) Storage Management Initiative (SMI), providing an American National Standards Institute (ANSI) standard for storage management. The SMI has developed 11

12 a standard management interface that has culminated in a comprehensive specification, SMI-S. The specification defines the open storage management interface that enables the interoperability of multi-vendor storage-management technologies. These technologies are used to monitor and control storage resources in multi-vendor or SAN topologies. EMC PowerPath/VE Microsoft System Center 2012 EMC PowerPath/Virtual Edition (VE) software is used on the ESXi hosts in the VMware high availability (HA) cluster. PowerPath allows the host to connect to a LUN through more than one storage processor port on the EMC VNX series; this is known as multipathing. PowerPath optimizes multipathed LUNs through load-balancing algorithms. Port-load balancing equalizes the I/O workload over all available channels. Hosts connected to the VMAX benefit from multipathing, which provides the following advantages: Failover from port to port on the same storage processor, maintaining an even system load and minimizing LUN trespassing on VNX Port-load balancing across storage processor ports and host bus adapters (HBAs) Higher bandwidth attachment from host to storage system Microsoft System Center 2012 SP1 is a comprehensive, unified management platform that enables easy and efficient management of IT environments, including virtual/physical server infrastructures and client devices, for both traditional data centers and private clouds. SCVMM 2012 SCVMM is a management solution for the virtualized data center, enabling you to configure and manage your virtualization host, networking, and storage resources in order to create and deploy virtual machines and services across the virtual infrastructure. SCO 2012 SCO provides a workflow management solution for the data center. It enables administrators to automate the creation, monitoring, and deployment of resources in the environment. SCOM 2012 SCOM provides organizations with a flexible and cost-effective solution for monitoring their storage, computers, networks, and applications in a single console view. Operators can gain rapid insight into the state of their environment as well as receive alerts generated for availability, performance, configuration, and security situations. 12

13 SCOM MPs SCOM MPs contain settings that enable agents to monitor a specific service or application in SCOM. These settings include discovery information that allows management servers to automatically detect and begin monitoring objects, a knowledge base that contains error and troubleshooting information, rules and monitors that generate alerts, and reports. SCOM MPs might also contain tasks, diagnostics, and recovery tools and guidance to help fix problems. Multi-hypervisor environments Most companies have adopted some form of virtualization within their infrastructures, typically through the use of VMware ESXi or Microsoft Hyper-V virtualization technology. Many companies who initially chose one product over another often find themselves running both Hyper-V and ESXi together with the challenge of administering and monitoring a multi-hypervisor environment. This solution shows how to administer and monitor both Microsoft Hyper-V and VMware ESXi. Microsoft Windows Server 2012 Hyper-V Microsoft Windows Server 2012 Hyper-V is a hypervisor-based server virtualization product that can be installed as both software and "bare-metal" configurations. VMware ESXi VMware ESXi is a "bare-metal" hypervisor, which means software is installed directly on the physical server. Both Hyper-V and ESXi virtualization technologies enable the partitioning of resources into multiple virtual machines, allowing organizations to improve server utilization, reduce costs, and react more quickly to changing infrastructure and business needs. 13

14 Solution architecture and configuration Overview Physical environment This solution architecture validates a private cloud infrastructure for companies looking for enterprise consolidation with simplified management. System Center 2012 SP1 is used to manage compute, network, and storage resources in a multihypervisor, multi-array environment running mixed workloads of SQL Server 2012, SharePoint 2010, and Exchange Figure 1 displays the physical architecture of the solution. Figure 1. Solution architecture 14

15 Hardware resources Table 2 details the hardware resources used in this solution. Table 2. Hardware resources Equipment Quantity Configuration Storage platform 1 1 VNX5700 VMAX 10K Switches 2 2 * 40-port Fabric Interconnect switches Physical server 1 Single Chassis - 8 * blades Intel Xeon E7 2860: Two sockets each blade 10 cores per socket 256 GB memory each blade Software resources Table 3 details the software resources used in this solution. Table 3. Software resources Resource Quantity Version Purpose EMC VMAX 10K operating environment EMC VNX block operating environment VMAX 10K operating environment VNX operating environment ESI Provisioning new storage and enhanced storage views and reporting EMC PowerPath/VE Advanced multipathing for ESXi host HBAs Windows Server Hyper-V Server operating system Windows Server R2 Enterprise Edition, x64, SP1 Server operating system VMware ESXi Hypervisor software Microsoft SQL Server Enterprise Edition Database servers for: SQL Server OLTP SharePoint Microsoft SQL Server R2 Database Server for Microsoft System Center Microsoft SharePoint SP1 August 2012 cumulative update SharePoint farm EMC SMI-S Provider Storage management support for EMC arrays 15

16 Resource Quantity Version Purpose SCVMM SP1 Virtual infrastructure management SCOM SP1 Environment health monitor SCO SP1 Workflow management Workload profile Table 4, Table 5, and Table 6 detail the environment workload profiles used in validating this solution. Table 4. Microsoft SQL Server 2012 workload profile Profile characteristic SQL Server instances 1 Quantity/Type/Size OLTP database (OLTP_DB) Workload type 50,000 users/500 GB OLTP-like (90:10 read/write ratio) Table 5. Microsoft SharePoint 2010 workload profile Profile characteristic Total user count Total data Content DB sizes Quantity/Type/Size 15,000 users with 2 WFEs 4.3 TB 4 TB 200 GB 100 GB Number of Content DBs 3 Document size range 200 KB to 2 MB, average 335 KB Total site collection count 3 Size per site 10 GB to 400 GB Sites per site collection 10 to 100 Total site count 120 Table 6. Microsoft Exchange 2010 workload profile Profile characteristic Quantity/Type/Size Number of Exchange 2010 users 5,000 Number of Mailbox Server virtual machines 2 Number of database availability groups (DAGs) and database copies 1 DAG with 2 copies 16

17 Profile characteristic Number of users per Mailbox Server User profile (in DAG configuration) Read/write ratio Mailbox size Target average message size Deleted-items retention window Logs protection buffer 24 x 7 background database maintenance configuration Quantity/Type/Size 5,000 total mailboxes (2,500 active and 2,500 passive during normal operating conditions) 100 messages/user/day (0.10 IOPS) 3:2 in a DAG configuration Start at 500 MB, grow to 2 GB 75 KB 14 days 3 days Enabled Storage layout This solution used both a VNX5700 and VMAX 10K to provide storage. Both arrays allowed the provisioning of storage with different RAID types for each tier: The VNX storage array was provisioned with a single mixed storage pool to host OS, SharePoint, and SQL Server volumes. Note Co-location of SQL Server and SharePoint workloads is discussed further in the EMC FAST VP and Test results sections. The VMAX 10K was provisioned with two pools, each of which hosted Exchange DAG copies. Note Both a VNX5700 and VMAX 10K were used in this solution in order to showcase management of a multi-array environment. EMC VNX5700 Starting with a mixed pool of 18 SAS disks in a RAID 5 configuration and 8 NL-SAS disks in a RAID 6 configuration, we included an additional 18 SAS disks in the pool to validate the new in-tier rebalance feature of the VNX. We added another five Flash disks to the pool to validate the extreme performance improvements offered by solid state drives for OLTP-like workloads. FAST VP was enabled throughout testing. EMC VMAX 10K With efficiency in mind, we pooled Exchange DAG copies into two common virtually provisioned (thin) pools, because Microsoft recommends separating DAG active/passive members to different physical disks. Each of the log and data storage devices in DAG 1 and DAG 2 consisted of 24 x 2 TB SATA drives; a total of 48 drives serviced the Exchange workload. We configured the pools using RAID 1, and the storage was allocated on demand (as requested from the Exchange servers) and wide striped across the thinly provisioned pools. 17

18 Storage configuration This section shows the storage configurations used in the EMC VNX5700 and Symmetrix VMAX 10K arrays. Table 7 details the VNX5700 storage configuration for the solution. Table 7. EMC VNX5700 storage configuration RAID type Pool/RAID group Disk configuration Purpose RAID RAID RAID RAID Pool 0 18 x 600 GB SAS Hyper-V hosted OS volumes, SQL databases, SharePoint configuration, search and temp databases, log files 8 x 2 TB NL-SAS SharePoint content databases 18 x 600 GB SAS Pool expansion for performance 5 x 100 GB Flash Pool expansion for extreme performance HS RG x 100 GB Flash Hot spare HS RG 493 and RG x 600 GB SAS Hot spare HS RG x 2 TB NL-SAS Hot spare Table 8 details the VMAX 10K storage configuration for the solution. Table 8. EMC VMAX 10K storage configuration RAID type Pool/RAID group Disk configuration Purpose RAID 1 DAG1 24 x 2T SATA drives To host Exchange DB and log of DAG 1, ESXi hosted OS volumes RAID 1 DAG2 24 x 2T SATA drives To host Exchange DB and log of DAG 2, ESXi hosted OS volumes HS N/A 2 x 2T SATA drives Hot spare 18

19 VNX5700 storage allocation We configured the VNX5700 storage pool enabled by EMC FAST VP to host a total of ten LUNs, as shown in Table 9. The LUNs hosted virtual machine operating system files, along with SQL Server data, log, and TempDB files, for both the SQL Server OLTP database and SharePoint web farm. Table 9. VNX5700 LUN configuration with three-tier storage pool enabled by FAST VP LUN name Tier RAID type LUN capacity (GB) FAST VP policy Admin_VM_OS RAID App_VM_OS 700 SQL_Data 600 SQL_TempDB_Logs 300 SP_ContentDatabase_Log 480 Auto SP_ConfigDB 120 SearchDB_TempDBs 1,100 SP_SearchDB_TempDB_Log 110 SP_Index_Query 500 SP_ContentDatabases RAID 6 5,000 Lowest EMC FAST VP We used EMC FAST VP to provide automated storage optimization across a three-tier pool design consisting of the following drives: Flash: For extreme performance SAS: For performance NL-SAS: For capacity RAID 5 was used for both the Flash and SAS tiers in this solution to provide a good compromise between performance and capacity, and a low total cost of ownership (TCO). Available with the latest VNX FLARE code is a new RAID (8+1) configuration type for storage pools that lowers the number of parity disks required for larger storage pool tiers. RAID 6 (6+2) was used for the NL-SAS tier. Providing protection against double disk failure, RAID 6 is a good choice for production data on NL-SAS. Although the latest VNX FLARE also offers a new 14+2 RAID configuration in storage pools, this solution kept to a 6+2 configuration, which was sufficient for capacity requirements. Table 9 shows the configuration including the tiering policies used. As SharePoint content database I/O characteristics are generally large random read/writes, the tiering policy for the LUN that hosts this data was set to pin the data to the lowest available tier. This allowed segregation of this particular I/O to the NL-SAS tier within the pool. Remaining LUN tiering policies were set to start high then auto-tier, allowing EMC FAST VP to automatically relocate data at a sub-lun level based on I/O activity, prioritizing the 1 GB slices within each LUN so that the most active data was relocated to the higher-performing tier. 19

20 VMAX 10K storage allocation Table 10 details the storage LUNs provisioned for the solution from the VMAX 10K array, which hosted the Exchange environment that included data and OS volumes for the Exchange virtual machines. Table 10. VMAX 10K LUN design for Exchange LUN name RAID type Storage pool Databases_LUN_1 RAID 1 User capacity (GB) 17,000 Log_LUN_1 RAID 1 1,000 DAG 1 EXHT01_OS RAID 1 60 EXMBX01_OS RAID 1 60 Databases_LUN_2 RAID 1 17,000 Log_LUN_2 RAID 1 1,000 DAG 2 EXHT02_OS RAID 1 60 EXMBX02_OS RAID

21 System management design and configuration Overview This solution uses the following EMC and Microsoft components to provide a centralized management platform for an enterprise-level private cloud using EMC storage infrastructure. The ESI and SMI-S components serve as the enablers for the operations carried out by the Microsoft components, and their relationships are explained in this section. EMC components EMC components include: ESI for Windows Suite ESI for Windows Suite includes the ESI Management Packs for SCOM, providing storage discovery and health monitoring. The suite also includes ESI PowerShell for storage provisioning. SMI-S The EMC SMI-S Provider allows discovery and management of EMC storage in SCVMM. Note These components are free to EMC customers. Interoperability with Microsoft components Microsoft components include: SCOM 2012 SP1 SCOM 2012 SP1 with ESI Management Packs provides discovery and monitoring of EMC storage. ESI Management Packs use the ESI Service to communicate with storage. ESI Management Packs and ESI Service should be installed together. SCVMM 2012 SP1 SCVMM 2012 SP1 provides management of both Hyper-V and ESXi clusters. Along with discovery and management of EMC storage, it also provides the ability to provision virtual machines through the EMC SMI-S Provider. EMC SMI-S is installed on the SCO server as an SMI-S provider. Note SCO 2012 SP1 Management of ESXi clusters requires vcenter Server. SCO uses runbooks to perform repeatable operations such as: Automated virtual machine provisioning Automated storage provisioning using ESI PowerShell 21

22 Figure 2 is a visual representation of the relationship between the EMC and Microsoft components. Figure 2. System management design for the solution Note SMI-S cannot be installed on the SCVMM management server or SCOM server. Monitor and report This section highlights the application and storage monitor features available in SCOM and also lists some key steps required for discovery and monitoring of EMC storage using SCOM 2012 SP1 with ESI Management Packs. This solution also uses SCOM 2012 SP1 to discover and monitor the health, performance, and availability of the entire virtual infrastructure across Exchange, SQL Server, and Sharepoint applications as well as the operating systems and hypervisors. Figure 3 shows SCOM 2012 monitoring all Windows servers including Windows Server 2012 and Hyper-V hosts. 22

23 Figure 3. SCOM 2012 management console ESI Management Packs The following six ESI Management Pack files are provided free of charge to EMC customers: EMC.ESI.Library.mp: Defines the monitors of storage systems supported by ESI and system components in SCOM. EMC.ESI.Discovery.mp: Contains all of the discoveries for all of the storage systems and system components as defined in the library. EMC.ESI.Monitoring.mp: Contains the monitors, rules, and diagnostics for the storage systems and system components. EMC.ESI.Presentation.mp: Presents the storage system and system component folders and views in SCOM. EMC.ESI.Reporting.mp: Reports the health and capacity of the storage systems and system components. EMC.SI.Customization.xml: Contains all of the overrides and customizations for your specific storage environment. Import this management pack only during an initial installation. If you import it again, you will lose all of your previous overrides and customizations. Figure 4 shows the ESI Management Packs loaded and available in SCOM. 23

24 Figure 4. ESI Management Packs in SCOM For example, the ESI Monitoring Management Pack is used to discover EMC storage system components. The discovery and monitoring of these components is through SCOM agents. The monitoring agent retrieves data from the ESI Service by using a RESTful HTTPS connection, which in turn retrieves the data from the storage systems. The monitoring data is inserted into the SCOM database. Figure 5 shows the overall topology of storage systems used in this solution. A capacity alarm was configured to trigger an alert when storage pool utilization went above 90 percent. Storage pool capacity was then exceeded, triggering the alerts as shown in the diagram. Figure 5. Overall topology view of storage system in SCOM 24

25 The ESI Managements Packs are installed and imported on the SCOM server, with the ESI Service providing the communications link between ESI and the SCOM Management Group. Figure 6 shows the ESI Service Overall Health status view available in the SCOM monitoring view. Figure 6. ESI Service health status Perform the following steps to enable storage monitoring in SCOM: 1. Install ESI Service on SCOM. 2. Install the ESI Management Packs for SCOM. 3. Add the storage system into ESI Service. 4. Import ESI Management Packs into SCOM. Note EMC Storage Integrator for Windows Suite Product Guide provides detailed ESI setup and configuration instructions. Storage monitoring with ESI Management Packs After storage monitoring was enabled in SCOM, the VNX5700 and VMAX 10K were discovered. This allowed alerts for any possible problems with disk devices, power supplies, storage pools, and other hardware being monitored by SCOM. Figure 7 shows the Storage Group Overall Health monitoring view. 25

26 Figure 7. Storage Group Overall Health monitoring view Figure 8 shows that storage pool monitoring is available in SCOM. As previously noted, SCOM was intentionally configured to trigger alerts when storage pools exceeded 90 percent capacity utilization. These alerts, which show a critical error state, notify you that the storage pool capacity needs to be expanded. Figure 8. Storage pool monitoring view 26

27 For detailed information about the error state, right-click the error state, select Open, and choose Health Explorer, as shown in Figure 9. Figure 9. How to view detailed information about error states SCOM allows monitoring of server components such as CPU and memory. Figure 10 shows the CPU Module Overall Health view available in SCOM. Figure 10. CPU Module Overall Health in SCOM monitoring view Application monitoring with SCOM MPs SQL Server The SQL Server Management Pack provides both proactive and reactive monitoring for Microsoft SQL Server 2005, SQL Server 2008, SQL Server 2008 R2, and SQL Server Monitoring of SQL Server components such as database engine instances, databases, and SQL Server agents is available. 27

28 Figure 11 shows SCOM 2012 monitoring SQL Server. Because disk usage capacity for the two servers exceeded the set thresholds, warning states were triggered. Figure 11. SCOM 2012 SQL Server monitoring view SharePoint By detecting, sending alerts for, and automatically correlating critical events, the SharePoint Management Pack helps indicate, correct, and prevent possible service outages or configuration problems, allowing you to proactively manage SharePoint servers and identify issues before they become critical. The management pack monitors and provides alerts for automatic notification of events indicating service outages, performance degradation, and health monitoring. Figure 12 shows SCOM monitoring the SharePoint farm. When disk usage capacity for the four servers exceeded set thresholds, warning states were triggered. Figure 12. SCOM SharePoint monitoring view 28

29 Exchange The Microsoft Exchange Server 2010 Management Pack includes a complete health model, extensive protocol synthetic transaction coverage, and a full complement of diagnostics-based alerts and service-oriented reporting, including mail flow statistics. Figure 13 shows SCOM Exchange 2010 monitoring. When disk usage capacity for two of the servers exceeded set thresholds, warning states were triggered. Figure 13. SCOM Exchange 2010 monitoring view Reporting SCOM 2012 with SCVMM Management Packs provides administrators with an easy way to gather data and generate reports about a private cloud. After the SCVMM Management Packs are imported into SCOM, administrators can generate reports for tracking the logical and physical consumption of resources within the private cloud fabric (storage, network, and compute). Figure 14 displays the System Center 2012 Virtual Machine Manager Reports screen. 29

30 Figure 14. System Center 2012 Virtual Machine Manager Reports screen The following descriptions of two reports highlight this feature s functionality. Host utilization Figure 15 shows host utilization for one of the Hyper-V nodes, which is hosting several virtual machines. This allows administrators to gain an understanding of the utilization of host resources. 30

31 Figure 15. Sample report of Hyper-V host utilization Chargeback SCOM SP1 includes basic chargeback reporting functionality. The following fields should be completed in the parameter header of the Chargeback report to help provide meaningful results: Date Range: Provide date range of the report. Objects: Identify, for example, virtual machines that are deployed to the cloud. Billing Units: Assign a cost to memory, CPU, or a base cost for a virtual machine. Figure 16 shows the parameter header in the Chargeback report with billing units highlighted. Figure 16. Parameter header in Chargeback report 31

32 Figure 17 shows the result of a sample report run in the solution. This report would allow an organization s finance department to process the resulting cross-charge as required. Figure 17. Sample report for chargeback in SCOM 2012 Cloud management SCVMM 2012 SP1 provides an interface to manage Hyper-V, ESXi, and a variety of EMC storage arrays through EMC s close integration with System Center. Note SCVMM 2012 SP1 must be installed on Windows Server Hyper-V management The solution includes one Hyper-V cluster containing four nodes, all running Windows Server 2012 Datacenter Edition. The nodes were added to SCVMM 2012 SP1 and properties were configured, allowing for configuration of virtual machines and other functions such as live migration and storage migration. Note Refer to thetechnical Documentation Download for System Center 2012 Virtual Machine Manager paper on Microsoft s website ( /p/?LinkID=265115). 32

33 Figure 18 shows SCVMM 2012 SP1 managing the Windows Server 2012 features on the four Hyper-V nodes. Figure 18. SCVMM 2012 managing Hyper-V features of Windows Server 2012 ESXi management SCVMM 2012 SP1 support for ESXi is optimized for virtual machine and service management. SCVMM 2012 SP1 integrates directly with VMware vcenter Server. The SCVMM console lets you manage day-to-day operations of VMware ESXi hosts and host clusters, such as the discovery and management of ESXi hosts, and the ability to create, manage, store, place, and deploy virtual machines on ESXi hosts. Advanced fabric management, such as the configuration of port groups, standard and distributed virtual switches, vmotion, and Storage vmotion, must be done through vcenter Server. By integrating with vcenter Server to manage ESXi hosts, SCVMM 2012 SP1 can recognize and support VMware features such as vmotion. Figure 19 shows that SCVMM 2012 SP1 manages the VMware ESXi hosts in this solution. Figure 19. SCVMM 2012 managing VMware ESXi hosts 33

34 Figure 20 shows that SCVMM 2012 manages all Hyper-V and ESX hosts in the environment. Figure 20. SCVMM 2012 managing both Hyper-V and ESXi environments The following key steps are required to manage ESXi 5.0.1: 1. In the Fabric management menu, click Add Resources, and then add the vcenter Server as shown in Figure 21. Figure 21. Adding the vcenter in SCVMM console 2. Add the ESXi hosts to SCVMM SP1. 3. Retrieve certificates from the ESXi hosts. Right-click on each ESXi host and choose Properties, and then click Retrieve under management tab as shown in Figure

35 Figure 22. Retrieval of certificate from ESXi host Actions like vmotion can be done using SCVMM 2012 SP1. Figure 23 shows SCVMM 2012 SP1 performing vmotion on the ESXi cluster. Figure 23. SCVMM performing vmotion on ESXi cluster 35

36 Storage management Besides managing and monitoring virtual environments, SCVMM 2012 SP1 also provides new storage discovery, storage classification, and storage allocation features. You can discover, classify, and provision storage on EMC arrays through the SCVMM console. SCVMM 2012 SP1 fully automates the assignment of storage to a Hyper-V host or Hyper-V host cluster, and tracks storage that is managed by SCVMM. Note Storage automation through SCVMM 2012 SP1 is only supported for Hyper-V hosts. To enable these storage features, SCVMM 2012 SP1 uses the new Microsoft Storage Management Service to communicate with external arrays through an SMI-S provider. The Storage Management Service is installed by default during the installation of SCVMM 2012 SP1. EMC provides the EMC SMI-S Provider that was installed on the SCO server in this solution. The provider is then added to the SCVMM management console as shown in Figure 24. Figure 24. Storage overview of SCVMM 2012 SP1 Components Figure 24 shows the four subcategories under the storage section: Classification and pools: Storage classifications enable you to assign userdefined storage classifications to discovered storage pools, typically by quality of service (QoS). For example, you could assign a classification of GOLD to storage pools that have the highest performance and availability. Providers: SMI-S provider server. Arrays: Storage arrays that are discovered. Refer to Configuring Storage in VMM Overview on Microsoft TechNet ( for supported arrays. 36

37 File Servers: SCVMM 2012 SP1 includes support for designating network file shares on Windows Server 2012 computers as the storage location for virtual machine files, such as configuration, virtual hard disk (.vhd/.vhdx) files and checkpoints. This functionality leverages the new 3.0 version of the Server Message Block (SMB) protocol that was introduced in Windows Server EMC storage discovery EMC provides its own SMI-S provider for SCVMM 2012 SP1. To configure SCVMM to discover the EMC storage systems, perform the following key steps: 1. Set up the SMI-S provider server. 2. Add the storage system into the SMI-S provider server. 3. Configure the SMI-S provider in SCVMM 2012 SP1 by expanding the storage pane. Right-click Providers, select Add storage devices, input the SMI-S provider server IP address, as shown in Figure 25, and assign Run As account for this provider. Figure 25. SMI-S provider configuration Note For detailed information about SMI-S provider setup and configuration, refer to the SMI-S provider release notes. Storage pool management SCVMM cannot create storage pools, but management of existing storage pools and creation of LUNs within pools is possible. To configure storage pools of EMC storage: 1. Expand arrays node under storage pane. 2. Right-click one of the EMC arrays and choose Properties. 3. Select the storage pools that SCVMM should manage, and then click OK. 37

38 Figure 26 shows the properties of storage pools on VMAX 10K. Figure 26. Managing storage pools on EMC storage LUN creation with SCVMM Following the selection of storage pools that SCVMM can manage, LUN creation is possible as shown in Figure Right-click the storage pane and choose Create Logical Unit. 2. Define in which storage pool you want to create this LUN. 3. Define name and size with thin or thick provision. Note Only VMAX 10K can use thin or thick options. 38

39 Figure 27. Create logical unit with SCVMM Workflow management This section shows how SCO 2012 SP1 and ESI PowerShell are used together to automatically provision virtual machines and concurrently provision the required storage. In SCO 2012 SP1 a runbook can automatically create and deploy virtual machines and provision storage as well as perform numerous other activities. The SCO 2012 SP1 Runbook Designer is used to design and manage runbooks, where all activities can be connected and the running order set. SCO preparation steps Before designing a runbook, complete the following steps on the SCO server: 1. Install and import SCVMM Integration Pack. 2. Install ESI and ESI PowerShell. 3. Set the PowerShell execution policy to unrestricted. Note For SCO installation and IP install and import, refer to Microsoft Technet at technet.microsoft.com. Runbook Designer In this section, we design a runbook to complete the following steps: 1. Create virtual machine and deploy it on the server. 2. Provide storage provisioning. 39

40 Figure 28 shows the Runbook Designer GUI. Figure 28. Runbook Designer GUI Step 1: Virtual machine creation and deployment The SCVMM Integration Pack provides virtual environment management activities such as Create virtual machine and Move virtual machine. Figure 29 shows the available SCVMM activities. Figure 29. Available SCVMM activities In the SCVMM activites, select Create VM From Template; this activity automatically creates virtual machines from an existing template and deploys them on a dedicated host or cluster. Figure 30 shows the properties of the Create VM From Template activity. 40

41 Figure 30. Properties of Create VM From Template activity Step 2: Storage provisioning After the virtual machine is created, ESI PowerShell scripts are used to provide the storage provisioning for the virtual machine. In SCO 2012, we can use the Run.Net Script activity and select PowerShell as the language. To provision storage to the virtual machine: 1. Create a disk in a storage pool and assign it to the required host. Figure 31 shows the Details properties of the Create Disk with ESI PowerShell activity. 41

42 Figure 31. Details properties of Create Disk with ESI PowerShell activity 2. Add the disk to the virtual machine that was just created as shown in Figure 32. Figure 32. Details properties of the Add disk to VM with ESI PowerShell activity 42

43 Note The ESI PSToolkit module must be imported before running other cmdlets. For detailed information about ESI PSToolkit, refer to the EMC Storage Integrator for Windows Suite Online Help. Now SCO is ready to start the automation process. The test results are shown in the Validation section. 43

44 Application design and configuration Overview The environment was configured to support an application profile consisting of a single SQL Server 2012 instance, a medium-sized SharePoint farm, and a mediumsized Exchange implementation consisting of two DAG copies. In this solution SQL Server and SharePoint were collocated in a single three-tier (heterogeneous) pool, enabled by FAST VP and consisting of Flash, SAS, and NL-SAS drives, on the VNX5700. The Exchange DAG copies were each hosted in their own (homogenous) pool of SATA drives. Co-location of SQL Server and SharePoint volumes Co-location of application workloads such as SQL Server and SharePoint can help simplify storage layout. Attention should be paid to the type of the I/O workloads when doing this. In this solution, an OLTP SQL Server workload was located with SharePoint in a three-tier storage pool. SharePoint content databases are generally large random read/writes. The tiering policy for the LUN that hosts this data was set to pin the data to the lowest available tier of NL_SAS disks, allowing segregation of this particular I/O to the NL-SAS tier within the pool. The remaining LUNs hosting files have smaller random (data files), semi-random (TempDB), or sequential (log files) workloads to be automatically tiered across the remaining Flash and SAS tiers via FAST VP. The results of this approach are shown in Table 23. If an environment is required to support Data Warehouse (DW) workloads, then consider using dedicated storage pools to isolate DW workloads. These workloads generally consist of predominantly larger I/O sizes from 64 KB to 256 KB and read/write ratios of 95:5. Isolation to separate disks can reduce the impact of DW workloads on critical OLTP database performance. TempDB can also encounter heavy use in DW workloads and its location should be carefully selected to reduce impact. Locating OLTP and DW workloads to separate SQL instances where possible ensures application performance. Ideally, Exchange workloads should be segregated with each DAG copy located in its own pool. In this configuration, two pools of SATA drives were configured on the VMAX 10K. SQL Server 2012 Design and requirements As shown in Table 11, the SQL Server 2012 configuration consisted of one instance hosting a single 500 GB database named OLTP_DB. A heavy OLTP-like workload with a read/write ratio of approximately 90:10 was run against the database that has a total user count of 50,

45 Table 11. SQL Server user requirements Profile characteristic SQL Server Instances 1 Quantity/Type/Size OLTP database (OLTP_DB) Workload type 50,000 users/500 GB OLTP-like (90:10 read/write ratio) Configuration The database was made up of nine data files in a single 600 GB VHDX file that was hosted in a dedicated LUN. The transaction log file for OLTP_DB was collocated with the four TempDB files and one TempDB log file in a separate 300 GB VHDX file, again located to a dedicated LUN. TempDBs in OLTP environments generally produce small semi-random I/O, while Log files produce small sequential writes. In this solution locating these together provided a simple design while still guaranteeing performance. This allowed the OLTP_DB data file workload, which was of a random nature, to have uninterrupted access to its own dedicated VHDX/LUN. This kind of layout and separation is a good idea when looking for a simple and wellbalanced layout. Figure 12 shows the virtual machine configuration. Table 12. SQL Server virtual machine configuration Virtual machine role Quantity vcpu Memory (GB) SQL Server Boot disk VHDX (GB) SharePoint 2010 Design The SharePoint farm was designed as a medium-sized farm with two WFEs, one crawl server, one Microsoft SQL Server, and an application server. The farm was a publishing portal with site collections containing several Document Center sites. The entire farm, including boot volumes for the virtual machines and content databases, was stored on a single large mixed-storage pool. The farm consisted of three ContentDBs (4 TB, 100 GB, and 200 GB). Configuration We designed the storage for performance and capacity; the ContentDBs were stored on NL-SAS disks in a RAID6 6+2 configuration. ContentDBs were pinned to the NL-SAS tier in a mixed storage pool. The rest of the farm was stored in the same mixed storage pool, but not pinned to the lowest tier. 45

46 SharePoint 2010 user requirements Table 13 lists the SharePoint user requirements in this solution. Table 13. SharePoint user requirements Item Total user count Usage profile(s) (%browse/% search/%modify/%download) Value 15,000 with 2 WFEs 60%/10%/10%/20% User concurrency 10% Table 14 details the SharePoint virtual machine configuration. Table 14. SharePoint virtual machine configuration Virtual machine role Quantity vcpu Memory (GB) Web and Query Application Index SQL Server Boot disk VHDX (GB) Table 15 details the virtual machine disk configurations for the SharePoint farm. Table 15. Virtual machine disk configurations for SharePoint farm Virtual machine role Number of virtual machines VHDX disk size WFE and Query 2 60 GB Boot Description 200 GB Query Application 1 60 GB Boot Index 1 60 GB Boot 100 GB Index SQL Server 1 60 GB Boot 5 TB ContentDBs 470 GB ContentDB Logs 1TB Temp DBs 115 GB TempDB Logs 105 GB Config DBs 46

47 Exchange 2010 Microsoft Exchange Server 2010 introduces DAG as the new HA mechanism to replace legacy HA technologies. This section provides the design details for virtualization, DAG setup, and storage design for Exchange Server 2010 as deployed in this solution. Exchange Server 2010 user requirements Table 16 details the Exchange Server 2012 user requirements in this solution. Table 16. Exchange user requirements Item Value Number of Exchange 2010 users 5,000 Number of Mailbox Server virtual machines 2 Number of DAGs and database copies Number of users per Mailbox Server User profile (in DAG configuration) Read/write ratio Mailbox size Target average message size Deleted items retention window Logs protection buffer 1 DAG with 2 copies 5,000 total mailboxes (2,500 active and 2,500 passive during normal operating conditions) 100 messages/user/day (0.10 IOPS) 3:2 in a DAG configuration Start at 500 MB, grow to 2 GB 75 KB 14 days 3 days 24 x 7 BDM configuration Enabled Exchange Server 2010 building-block design Sizing and configuring storage for use with Exchange Server 2010 can be a complicated process driven by many variables and factors that vary from organization to organization. Properly configured Exchange storage, combined with a correctly sized server and network infrastructure, can guarantee smooth Exchange operations and the best user experience. One method that can simplify the sizing and configuration of large Microsoft Exchange Server 2010 environments is to define a unit of measure called a building block. A building block represents the required amount of resources needed to support a specific number of Exchange 2010 users on a single virtual machine. You can derive the number of required resources from a specific user profile type, mailbox size, and disk requirement. For more information about the EMC building-block methodology for Exchange 2010, refer to the EMC white paper Microsoft Exchange 2010 Storage Best Practices and Design Guidance for EMC Storage. 47

48 Table 17 shows the detailed building-block information for this solution. Table 17. Exchange building block Item Number of Exchange users per Mailbox Server Mailbox size Number of databases per Mailbox Server Value 5,000 total mailboxes (2,500 active and 2,500 passive during normal operating conditions) Start at 500 MB, grow to 2 GB 10 (5 active/5 passive) User mailboxes per database 500 Database LUN size Log LUN size 1.8 TB (sizing for 2 GB mailbox) 100 GB The requirements include starting with a user mailbox size of 500 MB with the ability to grow seamlessly to 2 GB. This can be accomplished easily using the Symmetrix VMAX 10K Virtual Provisioning feature. Symmetrix Virtual Provisioning technology builds on the base thin-provisioning functionality to have a large thin device (that is, volume) configured and presented to the host while consuming physical storage from a shared pool only as needed. Symmetrix Virtual Provisioning can improve storage capacity utilization and simplify storage management by presenting the application with sufficient capacity for an extended period of time, reducing the need to provision new storage frequently and avoiding the cost of allocated but unused storage. Exchange Server 2010 DAG design This solution uses the Exchange 2010 DAG feature to provide HA for Exchange databases. A DAG is a group of up to 16 Mailbox Servers that hosts a set of databases and provides automatic database-level recovery from failures that affect individual servers or databases. Each Mailbox Server in this solution was configured with ten databases: five active and five passive. All databases were balanced and distributed between Mailbox Servers within the DAG and between the ESXi nodes to eliminate a single point of failure. Figure 33 shows the DAG database distribution. Figure 33. Exchange 2010 DAG database distribution 48

49 ESXi virtual machine design for Exchange Server 2010 This solution deployed all the Exchange 2010 servers as ESXi virtual machines. Four Exchange 2010 Mailbox Servers were configured in a DAG to provide HA for databases. Each Mailbox Server virtual machine was set up on a separate ESXi host server for additional redundancy. From the HUB/CAS servers, the HUB/CAS combined role had a 1:1 CPU core ratio to the Mailbox Server. Therefore, the solution included four HUB/CAS servers as virtual machines, which were separated into different ESXi hosts. Furthermore, we deployed the Exchange Server 2010 Client Access array and network load balancer to provide load balancing between the Client Access servers. For the Exchange virtual machines, we based the memory and CPU requirements on Microsoft best practices. For more information, refer to the following papers on Microsoft TechNet: Understanding the Mailbox Database Cache ( Mailbox Server Processor Capacity Planning ( Table 18 provides a summary of the Exchange virtual machine configuration. Table 18. Exchange virtual machine configuration Virtual machine role Quantity vcpu Memory (GB) Mailbox HUB/CAS Boot disk VMDK (GB) All the database and log LUNs for the Exchange Mailbox Server virtual machine were configured as VMDK disks in ESXi. Table 19 provides detailed information on the Exchange virtual machine pass-through disk configuration. Table 19. Exchange virtual machine disk configuration Virtual machine role Number of virtual machines VMDK disks Description Number of VMDK disks on each virtual machine Mailbox TB Database LUNs GB Log LUNs 10 49

50 Hyper-V Cluster This solution deploys a Hyper-V cluster consisting of four nodes to increase the availability of virtual machines and applications. When determining where to place the virtual machines, consideration of load balancing and failure protection in your plan is important. You should distribute virtual machines with the same application roles as the different Hyper-V root servers, as shown in Table 20. Table 20. Hyper-V cluster deployment VM role vcpu Memory (GB) Node 1 SharePoint SQL Server 8 64 SharePoint WFE 4 6 SharePoint WFE 4 6 Total Node 2 SharePoint App Server 2 4 SharePoint Crawl Server 4 8 Total 6 12 Node 3 SQL Server Total ESXi cluster In addition to the Hyper-V cluster, this solution also uses an ESXi cluster. The Exchange 2010 virtual machine is distributed between the two nodes, as shown in Table 21. Table 21. ESXI cluster deployment VM role vcpu Memory (GB) Node 1 Exchange Mailbox Server 8 24 Exchange Hub/CAS Server 4 8 Total Node 2 Exchange Mailbox Server 8 24 Exchange Hub/CAS Server 4 8 Total

51 Validation Overview The testing section covers the following areas: Functionality and integration of ESI for Windows Suite Provisioning Automated storage provisioning as part of virtual machine creation New features available on the VNX Support for different RAID types across tiers In-tier storage rebalance New RAID configuration types RAID 5, 8+1 (used in SAS tier) RAID 6, 14+2 (not used) Co-location of SQL and SharePoint workloads in a storage pool enabled by EMC FAST VP Validating a multi-hypervisor, multi-array environment running SQL Server, SharePoint, and Exchange workloads Test methodology Functional testing of System Center 2012 with EMC components To validate the functionality of System Center 2012 SP1, the following scenarios were covered. SCOM 2012 SP1 with ESI Management Pack testing To verify that SCOM 2012 SP1 with ESI Management Packs can provide realtime monitoring of EMC storage systems, the following tests were completed: Remove disk and check if SCOM shows alert Reboot storage processor (SP) and check if SCOM shows alert SCO 2012 SP1 with ESI PowerShell To verify the use of ESI PowerShell with SCO and SCVMM Integration Pack to automate storage provisioning, perform the following steps: 1. Create a new runbook in the SCO Runbook Designer and assign the following activities in the order provided: a. Create virtual machine from Template. b. Create disk with ESI PowerShell. c. Add a disk to virtual machine with ESI PowerShell. Note Create disk used here refers to the creation of a Hyper-V virtual volume (VHDX file). 51

52 ESI PowerShell extends additional options to the user by enabling creation not only of a virtual volume, but also of a new EMC Array LUN, and assigning the appropriate virtual volumes to the new storage LUN. Optionally, this LUN can be included as a Clustered Shared Volume (CSV). This functionality is a powerful tool, enabling administrators to automate repeatable complex storage operations. 2. Run the sequence with the Runbook Tester, as shown in Figure 34. Figure 34. Runbook Tester 3. Run Orchestrator Console. After confirming that the runbook can run smoothly, check the runbook into the Runbook Designer and use Orchestrator Console to run it. Orchestrator Console, shown in Figure 35, is a web console for SCO; it is a placeholder to run and manage runbooks. 52

53 Figure 35. Orchestrator Console EMC VNX in-tier rebalance functionality To test the functionality of the in-tier rebalance feature with VNX testing methodology, perform the following steps: 1. Create an initial storage pool consisting of: 18 * SAS 600 GB 10k disks 8 * NL-SAS 2TB disks 2. Add additional disks to the SAS tier to expand the VNX storage pool: 18 * SAS 600 GB 10k disks 3. Add additional Flash drives to the storage pool to create an extreme performance tier: 5 * 100 GB Flash drives During testing, performance was measured at each stage. Application performance across the environment This solution also validated the performance for the final configuration across all applications in the environment. 53

54 SQL Server We conducted SQL Server testing by running OLTP-like workloads against a single SQL Server instance. Workload generated was sufficient to push the initial storage pool configuration to a point where additional disks were required. During in-tier rebalance, the workload was halved with any environment change, and operations were conducted outside peak hours. For the addition of Flash drives, full workload was used and no subsequent increase was made. SharePoint We used Microsoft Visual Studio Team System (VSTS) to simulate the load on the SharePoint farm. A client load emulation tool was used to ensure that the SharePoint farm was operating at the optimal performance level. All users adhered to a Microsoft heavy-user profile, which specifies 60 requests per hour. A think time of zero percent was applied to all tests. Zero think time is the elimination of typical user decision-making time when browsing, searching, or modifying data using Microsoft Office SharePoint Server. Every user request is completed from start to finish without a pause, which generates a continuous workload on the system. The maximum user capacity is derived from the following formula: # = seconds per hour / RPH / Concurrency% * RPS Example: 3600/60/1% * = 204,900 Example: 3600/60 /10% * = 20,490 (supported user capacity for 10 percent concurrency) Table 22 lists the response time for each organization. Table 22. Response time Test type Action Percentage Response time Browse User browse 60 Less than 3 seconds Search Modify Download Unique value search Metadata modify and upload Download a document 10 Less than 3 seconds 10 Less than 3 seconds 20 Less than 3 seconds 54

55 Microsoft Exchange Load Generator Microsoft Exchange Load Generator (LoadGen) is a simulation tool used to measure the impact of MAPI, OWA, ActiveSync, IMAP, POP, and SMTP clients on Exchange Server 2010 and LoadGen allows you to test how a server running Exchange 2010/2007 responds to loads. These tests send multiple messaging requests to the Exchange Server, which causes a mail load. LoadGen is a useful tool for administrators who are sizing servers and validating a deployment plan. Specifically, LoadGen helps organizations determine if each of their servers can handle the load that they are intended to carry. LoadGen requires a full deployment of the Exchange environment for validation testing. Customers should perform all LoadGen validation testing in an isolated lab environment with no connectivity to production data. To get a copy of LoadGen tool, visit the Microsoft Download Center at Test results SCOM test and result The following three tests were executed and, as expected, resulted in alerts being generated within SCOM: Removal of a disk Reboot of VNX SP Power off host server Test 1: Remove disk to validate warning by SCOM monitoring view After removal of a disk from the VMAX 10K, the state of the VMAX 10K changed to critical in the SCOM monitoring view for active alerts for ESI, as shown in Figure 36. Figure 36. Critical warning for VMAX 10K disk status in SCOM monitoring view 55

56 Test 2: Reboot VNX SP to validate warning in SCOM After rebooting the VNX SP, the state of the VNX returned a warning as shown in Figure 37. After the SP completed rebooting, the warning message disappeared. If there was a permanent error with the SP, the warning would change to a critical-state error for the VNX array. Figure 37. Warning for VNX storage processor status in SCOM monitoring view Test 3: Power off host server to validate warning in SCOM For this test, we powered off one of the host servers in the Hyper-V cluster to simulate a server hardware failure. As shown in Figure 38, SCOM provided an alert for the loss of the host. Figure 38. Critical warning for loss of host server in SCOM SCO test for creation of VM with automatic provisioning of storage This test validated the ESI PowerShell runbook created with the SCO Runbook Designer. The runbook includes the creation of the virtual machine, SCOTEST, and provisioning of the storage. In this solution we created a new virtual machine to add another Web Front End (WFE) to the SharePoint farm. The additional disk is used by the WFE as a Query LUN. 56

57 To initiate the ESI PowerShell runbook, select the runbook in the Orchestrator Console, and then click Start Runbook as shown in Figure 39. Figure 39. Orchestrator console view for runbooks The runbook was successfully completed in five minutes for this scenario. We checked the SCVMM server to confirm that the virtual machine SCOTEST was successfully created. We then logged in to the SCOTEST virtual machine and confirmed the provisioning of storage, as shown in Figure 40. Figure 40. Virtual machine SCOTEST successfully created with storage provisioned After the virtual machine and additional disk are provisioned, the SharePoint administrator can install SharePoint and add the virtual machine to the SharePoint farm as a new WFE. This step can be further automated through the use of available tools, by automating the provisioning of additional WFE virtual machines or removal of unnecessary WFE virtual machines when needed. 57

EMC INTEGRATION FOR MICROSOFT PRIVATE CLOUD USING EMC VNX UNIFIED STORAGE

EMC INTEGRATION FOR MICROSOFT PRIVATE CLOUD USING EMC VNX UNIFIED STORAGE White Paper EMC INTEGRATION FOR MICROSOFT PRIVATE CLOUD USING EMC VNX UNIFIED STORAGE EMC Next-Generation VNX, EMC Storage Integrator for Windows Suite, Microsoft System Center 2012 SP1 Reduce storage

More information

EMC PERFORMANCE OPTIMIZATION FOR MICROSOFT FAST SEARCH SERVER 2010 FOR SHAREPOINT

EMC PERFORMANCE OPTIMIZATION FOR MICROSOFT FAST SEARCH SERVER 2010 FOR SHAREPOINT Reference Architecture EMC PERFORMANCE OPTIMIZATION FOR MICROSOFT FAST SEARCH SERVER 2010 FOR SHAREPOINT Optimize scalability and performance of FAST Search Server 2010 for SharePoint Validate virtualization

More information

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution EMC Virtual Infrastructure for Microsoft Applications Data Center Solution Enabled by EMC Symmetrix V-Max and Reference Architecture EMC Global Solutions Copyright and Trademark Information Copyright 2009

More information

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution EMC Virtual Infrastructure for Microsoft Applications Data Center Solution Enabled by EMC Symmetrix V-Max and Reference Architecture EMC Global Solutions Copyright and Trademark Information Copyright 2009

More information

EMC VFCACHE ACCELERATES ORACLE

EMC VFCACHE ACCELERATES ORACLE White Paper EMC VFCACHE ACCELERATES ORACLE VFCache extends Flash to the server FAST Suite automates storage placement in the array VNX protects data EMC Solutions Group Abstract This white paper describes

More information

MICROSOFT CLOUD REFERENCE ARCHITECTURE: FOUNDATION

MICROSOFT CLOUD REFERENCE ARCHITECTURE: FOUNDATION Reference Architecture Guide MICROSOFT CLOUD REFERENCE ARCHITECTURE: FOUNDATION EMC VNX, EMC VMAX, EMC ViPR, and EMC VPLEX Microsoft Windows Hyper-V, Microsoft Windows Azure Pack, and Microsoft System

More information

EMC INFRASTRUCTURE FOR MICROSOFT APPLICATIONS IN THE PRIVATE CLOUD

EMC INFRASTRUCTURE FOR MICROSOFT APPLICATIONS IN THE PRIVATE CLOUD White Paper EMC INFRASTRUCTURE FOR MICROSOFT APPLICATIONS IN THE PRIVATE CLOUD Automated performance optimization Centralized and simplified management Efficient, automated disaster recovery EMC Solutions

More information

EMC AUTOMATED PERFORMANCE OPTIMIZATION for MICROSOFT APPLICATIONS

EMC AUTOMATED PERFORMANCE OPTIMIZATION for MICROSOFT APPLICATIONS White Paper EMC AUTOMATED PERFORMANCE OPTIMIZATION for MICROSOFT APPLICATIONS Automated performance optimization Cloud-ready infrastructure Simplified, automated management EMC Solutions Group Abstract

More information

Brocade and EMC Solution for Microsoft Hyper-V and SharePoint Clusters

Brocade and EMC Solution for Microsoft Hyper-V and SharePoint Clusters Brocade and EMC Solution for Microsoft Hyper-V and SharePoint Clusters Highlights a Brocade-EMC solution with EMC CLARiiON, EMC Atmos, Brocade Fibre Channel (FC) switches, Brocade FC HBAs, and Brocade

More information

EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, Symmetrix Management Console, and VMware vcenter Converter

EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, Symmetrix Management Console, and VMware vcenter Converter EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, VMware vcenter Converter A Detailed Review EMC Information Infrastructure Solutions Abstract This white paper

More information

Leveraging EMC Fully Automated Storage Tiering (FAST) and FAST Cache for SQL Server Enterprise Deployments

Leveraging EMC Fully Automated Storage Tiering (FAST) and FAST Cache for SQL Server Enterprise Deployments Leveraging EMC Fully Automated Storage Tiering (FAST) and FAST Cache for SQL Server Enterprise Deployments Applied Technology Abstract This white paper introduces EMC s latest groundbreaking technologies,

More information

DEPLOYING VIRTUALIZED MICROSOFT DYNAMICS AX 2012 R2

DEPLOYING VIRTUALIZED MICROSOFT DYNAMICS AX 2012 R2 DEPLOYING VIRTUALIZED MICROSOFT DYNAMICS AX 2012 R2 EMC Solutions Abstract This document describes the reference architecture of a virtualized Microsoft Dynamics AX 2012 R2 implementation that is enabled

More information

Building the Virtual Information Infrastructure

Building the Virtual Information Infrastructure Technology Concepts and Business Considerations Abstract A virtual information infrastructure allows organizations to make the most of their data center environment by sharing computing, network, and storage

More information

MICROSOFT HYPER-V SCALABILITY WITH EMC SYMMETRIX VMAX

MICROSOFT HYPER-V SCALABILITY WITH EMC SYMMETRIX VMAX White Paper MICROSOFT HYPER-V SCALABILITY WITH EMC SYMMETRIX VMAX Abstract This white paper highlights EMC s Hyper-V scalability test in which one of the largest Hyper-V environments in the world was created.

More information

EMC SYMMETRIX VMAX PERFORMANCE REVIEW FOR MICROSOFT EXCHANGE SERVER 2013

EMC SYMMETRIX VMAX PERFORMANCE REVIEW FOR MICROSOFT EXCHANGE SERVER 2013 EMC SYMMETRIX VMAX PERFORMANCE REVIEW FOR MICROSOFT EXCHANGE SERVER 2013 With EMC Virtual Storage Integrator (VSI) and VMware vsphere Storage building-block design Automated performance optimization with

More information

Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V. Reference Architecture

Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V. Reference Architecture Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V Copyright 2011 EMC Corporation. All rights reserved. Published February, 2011 EMC believes the information

More information

Using VMware VMotion with Oracle Database and EMC CLARiiON Storage Systems

Using VMware VMotion with Oracle Database and EMC CLARiiON Storage Systems Using VMware VMotion with Oracle Database and EMC CLARiiON Storage Systems Applied Technology Abstract By migrating VMware virtual machines from one physical environment to another, VMware VMotion can

More information

ADVANCED PROTECTION FOR MICROSOFT EXCHANGE 2010 ON EMC VNX STORAGE

ADVANCED PROTECTION FOR MICROSOFT EXCHANGE 2010 ON EMC VNX STORAGE White paper ADVANCED PROTECTION FOR MICROSOFT EXCHANGE 2010 ON EMC VNX STORAGE EMC VNX and EMC AppSync Complement your protection strategy using VNX Snapshots as a first line of defense for critical Exchange

More information

BEST PRACTICES FOR DEPLOYING VNX IN THE HYBRID CLOUD

BEST PRACTICES FOR DEPLOYING VNX IN THE HYBRID CLOUD 1 BEST PRACTICES FOR DEPLOYING VNX IN THE HYBRID CLOUD MICHAEL TRUITT; CORPORATE SOLUTION ENGINEERING 2 ROADMAP INFORMATION DISCLAIMER EMC makes no representation and undertakes no obligations with regard

More information

CONFIGURATION BEST PRACTICES FOR MICROSOFT SQL SERVER AND EMC SYMMETRIX VMAXe

CONFIGURATION BEST PRACTICES FOR MICROSOFT SQL SERVER AND EMC SYMMETRIX VMAXe White Paper CONFIGURATION BEST PRACTICES FOR MICROSOFT SQL SERVER AND EMC SYMMETRIX VMAXe Simplified configuration, deployment, and management for Microsoft SQL Server on Symmetrix VMAXe Abstract This

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING VMware Horizon 6.0 with View and VMware vsphere for up to 2,000 Virtual Desktops Enabled by EMC VNX and EMC Data Protection EMC VSPEX Abstract This describes

More information

EMC XtremSF: Delivering Next Generation Storage Performance for SQL Server

EMC XtremSF: Delivering Next Generation Storage Performance for SQL Server White Paper EMC XtremSF: Delivering Next Generation Storage Performance for SQL Server Abstract This white paper addresses the challenges currently facing business executives to store and process the growing

More information

Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4

Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4 Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4 Application Note Abstract This application note explains the configure details of using Infortrend FC-host storage systems

More information

EMC XTREMIO AND MICROSOFT EXCHANGE DATABASES

EMC XTREMIO AND MICROSOFT EXCHANGE DATABASES EMC XTREMIO AND MICROSOFT EXCHANGE DATABASES Preliminary findings: Efficiency of various production samples Market overview and adoption of all-flash arrays Techniques for estimating efficiency EMC Solutions

More information

Private cloud computing advances

Private cloud computing advances Building robust private cloud services infrastructures By Brian Gautreau and Gong Wang Private clouds optimize utilization and management of IT resources to heighten availability. Microsoft Private Cloud

More information

Virtualizing Microsoft SQL Server 2008 on the Hitachi Adaptable Modular Storage 2000 Family Using Microsoft Hyper-V

Virtualizing Microsoft SQL Server 2008 on the Hitachi Adaptable Modular Storage 2000 Family Using Microsoft Hyper-V Virtualizing Microsoft SQL Server 2008 on the Hitachi Adaptable Modular Storage 2000 Family Using Microsoft Hyper-V Implementation Guide By Eduardo Freitas and Ryan Sokolowski February 2010 Summary Deploying

More information

EMC Unified Storage for Microsoft SQL Server 2008

EMC Unified Storage for Microsoft SQL Server 2008 EMC Unified Storage for Microsoft SQL Server 2008 Enabled by EMC CLARiiON and EMC FAST Cache Reference Copyright 2010 EMC Corporation. All rights reserved. Published October, 2010 EMC believes the information

More information

Management of VMware ESXi. on HP ProLiant Servers

Management of VMware ESXi. on HP ProLiant Servers Management of VMware ESXi on W H I T E P A P E R Table of Contents Introduction................................................................ 3 HP Systems Insight Manager.................................................

More information

EMC CLARiiON PRO Storage System Performance Management Pack Guide for Operations Manager 2007. Published: 04/14/2011

EMC CLARiiON PRO Storage System Performance Management Pack Guide for Operations Manager 2007. Published: 04/14/2011 EMC CLARiiON PRO Storage System Performance Management Pack Guide for Operations Manager 2007 Published: 04/14/2011 Copyright EMC2, EMC, and where information lives are registered trademarks or trademarks

More information

MICROSOFT SHAREPOINT SERVER: BEST PRACTICES AND DESIGN GUIDELINES FOR EMC STORAGE

MICROSOFT SHAREPOINT SERVER: BEST PRACTICES AND DESIGN GUIDELINES FOR EMC STORAGE White Paper MICROSOFT SHAREPOINT SERVER: BEST PRACTICES AND DESIGN GUIDELINES FOR EMC STORAGE EMC VNX Family, EMC Symmetrix VMAX Systems, and EMC Xtrem Server Products Design and sizing best practices

More information

CONVERGED INFRASTRUCTURE SOLUTION FOR MICROSOFT SHAREPOINT, LYNC, AND EXCHANGE ON VCE VBLOCK SYSTEM 340

CONVERGED INFRASTRUCTURE SOLUTION FOR MICROSOFT SHAREPOINT, LYNC, AND EXCHANGE ON VCE VBLOCK SYSTEM 340 CONVERGED INFRASTRUCTURE SOLUTION FOR MICROSOFT SHAREPOINT, LYNC, AND EXCHANGE ON VCE VBLOCK SYSTEM 340 EMC Solutions Abstract This white paper provides a detailed reference architecture of Microsoft messaging

More information

EMC BACKUP-AS-A-SERVICE

EMC BACKUP-AS-A-SERVICE Reference Architecture EMC BACKUP-AS-A-SERVICE EMC AVAMAR, EMC DATA PROTECTION ADVISOR, AND EMC HOMEBASE Deliver backup services for cloud and traditional hosted environments Reduce storage space and increase

More information

IMPROVING VMWARE DISASTER RECOVERY WITH EMC RECOVERPOINT Applied Technology

IMPROVING VMWARE DISASTER RECOVERY WITH EMC RECOVERPOINT Applied Technology White Paper IMPROVING VMWARE DISASTER RECOVERY WITH EMC RECOVERPOINT Applied Technology Abstract EMC RecoverPoint provides full support for data replication and disaster recovery for VMware ESX Server

More information

VBLOCK SOLUTION FOR SAP APPLICATION HIGH AVAILABILITY

VBLOCK SOLUTION FOR SAP APPLICATION HIGH AVAILABILITY Vblock Solution for SAP Application High Availability Table of Contents www.vce.com VBLOCK SOLUTION FOR SAP APPLICATION HIGH AVAILABILITY Version 2.0 February 2013 1 Copyright 2013 VCE Company, LLC. All

More information

EMC Virtual Infrastructure for Microsoft SQL Server

EMC Virtual Infrastructure for Microsoft SQL Server Microsoft SQL Server Enabled by EMC Celerra and Microsoft Hyper-V Copyright 2010 EMC Corporation. All rights reserved. Published February, 2010 EMC believes the information in this publication is accurate

More information

Enterprise Manager. Version 6.2. Administrator s Guide

Enterprise Manager. Version 6.2. Administrator s Guide Enterprise Manager Version 6.2 Administrator s Guide Enterprise Manager 6.2 Administrator s Guide Document Number 680-017-017 Revision Date Description A August 2012 Initial release to support version

More information

EMC VNX FAMILY. Copyright 2011 EMC Corporation. All rights reserved.

EMC VNX FAMILY. Copyright 2011 EMC Corporation. All rights reserved. EMC VNX FAMILY 1 IT Challenges: Tougher than Ever Four central themes facing every decision maker today Overcome flat budgets Manage escalating complexity Cope with relentless data growth Meet increased

More information

Microsoft Exchange, Lync, and SharePoint Server 2010 on Dell Active System 800v

Microsoft Exchange, Lync, and SharePoint Server 2010 on Dell Active System 800v Microsoft Exchange, Lync, and SharePoint Server 2010 on Dell Active System 800v A Design and Implementation Guide with a sample implementation for 5,000 users Global Solutions Engineering This document

More information

EMC Data Protection Advisor 6.0

EMC Data Protection Advisor 6.0 White Paper EMC Data Protection Advisor 6.0 Abstract EMC Data Protection Advisor provides a comprehensive set of features to reduce the complexity of managing data protection environments, improve compliance

More information

Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820

Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820 Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820 This white paper discusses the SQL server workload consolidation capabilities of Dell PowerEdge R820 using Virtualization.

More information

Dell Compellent Storage Center SAN & VMware View 1,000 Desktop Reference Architecture. Dell Compellent Product Specialist Team

Dell Compellent Storage Center SAN & VMware View 1,000 Desktop Reference Architecture. Dell Compellent Product Specialist Team Dell Compellent Storage Center SAN & VMware View 1,000 Desktop Reference Architecture Dell Compellent Product Specialist Team THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL

More information

FEDERATION ENTERPRISE HYBRID CLOUD 3.1 Microsoft Applications Solution Guide

FEDERATION ENTERPRISE HYBRID CLOUD 3.1 Microsoft Applications Solution Guide FEDERATION ENTERPRISE HYBRID CLOUD 3.1 Microsoft Applications Solution Guide ABSTRACT This solution guide describes how to use the Federation Enterprise Hybrid Cloud 3.1 to provision and manage new and

More information

Best Practices for Microsoft

Best Practices for Microsoft SCALABLE STORAGE FOR MISSION CRITICAL APPLICATIONS Best Practices for Microsoft Daniel Golic EMC Serbia Senior Technology Consultant Daniel.golic@emc.com 1 The Private Cloud Why Now? IT infrastructure

More information

VBLOCK SOLUTION FOR A VIRTUALIZED, SCALABLE 50,000-USER MICROSOFT SHAREPOINT 2010 DEPLOYMENT

VBLOCK SOLUTION FOR A VIRTUALIZED, SCALABLE 50,000-USER MICROSOFT SHAREPOINT 2010 DEPLOYMENT www.vce.com VBLOCK SOLUTION FOR A VIRTUALIZED, SCALABLE 50,000-USER MICROSOFT SHAREPOINT 2010 DEPLOYMENT Version 2.0 February 2013 2013 VCE Company, LLC. All Rights Reserved. Copyright 2013 VCE Company,

More information

MICROSOFT EXCHANGE 2010 STORAGE BEST PRACTICES AND DESIGN GUIDELINES FOR EMC STORAGE

MICROSOFT EXCHANGE 2010 STORAGE BEST PRACTICES AND DESIGN GUIDELINES FOR EMC STORAGE White Paper MICROSOFT EXCHANGE 2010 STORAGE BEST PRACTICES AND DESIGN GUIDELINES FOR EMC STORAGE EMC Solutions Group Abstract Microsoft Exchange has rapidly become the choice of messaging for many businesses,

More information

Virtual SAN Design and Deployment Guide

Virtual SAN Design and Deployment Guide Virtual SAN Design and Deployment Guide TECHNICAL MARKETING DOCUMENTATION VERSION 1.3 - November 2014 Copyright 2014 DataCore Software All Rights Reserved Table of Contents INTRODUCTION... 3 1.1 DataCore

More information

Business Continuity for Microsoft Exchange 2010 Enabled by EMC Unified Storage, Cisco Unified Computing System, and Microsoft Hyper-V

Business Continuity for Microsoft Exchange 2010 Enabled by EMC Unified Storage, Cisco Unified Computing System, and Microsoft Hyper-V Chapte 1: Introduction Business Continuity for Microsoft Exchange 2010 Enabled by EMC Unified Storage, Cisco Unified Computing System, and Microsoft Hyper-V A Detailed Review EMC Information Infrastructure

More information

HP ProLiant PRO Management Pack (v 2.0) for Microsoft System Center User Guide

HP ProLiant PRO Management Pack (v 2.0) for Microsoft System Center User Guide HP ProLiant PRO Management Pack (v 2.0) for Microsoft System Center User Guide Abstract This guide provides information on using the HP ProLiant PRO Management Pack for Microsoft System Center version

More information

Microsoft System Center 2012 SP1 Virtual Machine Manager with Storwize family products. IBM Systems and Technology Group ISV Enablement January 2014

Microsoft System Center 2012 SP1 Virtual Machine Manager with Storwize family products. IBM Systems and Technology Group ISV Enablement January 2014 Microsoft System Center 2012 SP1 Virtual Machine Manager with Storwize family products IBM Systems and Technology Group ISV Enablement January 2014 Copyright IBM Corporation, 2014 Table of contents Abstract...

More information

EMC Storage Management Overview

EMC Storage Management Overview EMC Storage Management Overview Controlling The Cost Of Data Growth & Optimizing Storage Investments 1 The Storage Management Market Storage & Device Management Market Share EMC is the clear market share

More information

The Benefits of Virtualizing

The Benefits of Virtualizing T E C H N I C A L B R I E F The Benefits of Virtualizing Aciduisismodo Microsoft SQL Dolore Server Eolore in Dionseq Hitachi Storage Uatummy Environments Odolorem Vel Leveraging Microsoft Hyper-V By Heidi

More information

ACCELERATING MICROSOFT EXCHANGE 2010 PERFORMANCE WITH EMC XTREMCACHE

ACCELERATING MICROSOFT EXCHANGE 2010 PERFORMANCE WITH EMC XTREMCACHE White paper ACCELERATING MICROSOFT EXCHANGE 2010 PERFORMANCE WITH EMC XTREMCACHE EMC XtremSF, EMC XtremCache, EMC VNX, VMware vsphere, Microsoft Exchange 2010 EMC Solutions Abstract This white paper demonstrates

More information

www.vce.com SAP Landscape Virtualization Management Version 2.0 on VCE Vblock System 700 series

www.vce.com SAP Landscape Virtualization Management Version 2.0 on VCE Vblock System 700 series www.vce.com SAP Landscape Virtualization Management Version 2.0 on VCE Vblock System 700 series Version 1.1 December 2014 THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." VCE MAKES NO REPRESENTATIONS

More information

Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems

Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems Applied Technology Abstract This white paper investigates configuration and replication choices for Oracle Database deployment with EMC

More information

SharePoint Microsoft SharePoint has become

SharePoint Microsoft SharePoint has become The Essential Guide to SharePoint S p o n s o r e d b y Microsoft SharePoint has become a mission-critical platform for sharing information and delivering improved collaboration to organizations of all

More information

EMC PERSPECTIVE: THE POWER OF WINDOWS SERVER 2012 AND EMC INFRASTRUCTURE FOR MICROSOFT PRIVATE CLOUD ENVIRONMENTS

EMC PERSPECTIVE: THE POWER OF WINDOWS SERVER 2012 AND EMC INFRASTRUCTURE FOR MICROSOFT PRIVATE CLOUD ENVIRONMENTS EMC PERSPECTIVE: THE POWER OF WINDOWS SERVER 2012 AND EMC INFRASTRUCTURE FOR MICROSOFT PRIVATE CLOUD ENVIRONMENTS EXECUTIVE SUMMARY It s no secret that organizations continue to produce overwhelming amounts

More information

EMC VNX-F ALL FLASH ARRAY

EMC VNX-F ALL FLASH ARRAY EMC VNX-F ALL FLASH ARRAY Purpose-built for price, density & speed ESSENTIALS Incredible scale & density with up to 172 TB usable flash capacity in 6U @ 28.63 TB/U Consistent high performance up to 400K

More information

MICROSOFT EXCHANGE SERVER 2010 PERFORMANCE REVIEW USING THE EMC VNX5300 UNIFIED STORAGE PLATFORM

MICROSOFT EXCHANGE SERVER 2010 PERFORMANCE REVIEW USING THE EMC VNX5300 UNIFIED STORAGE PLATFORM White Paper MICROSOFT EXCHANGE SERVER 2010 PERFORMANCE REVIEW USING THE EMC VNX5300 UNIFIED STORAGE PLATFORM EMC GLOBAL SOLUTIONS Abstract This white paper focuses on the performance of the EMC VNX5300

More information

EMC Infrastructure for Microsoft Private Cloud

EMC Infrastructure for Microsoft Private Cloud White Paper EMC VNX5300, Replication Manager, Microsoft Hyper-V, Microsoft Exchange, SharePoint, Optimize infrastructure performance Cloud-ready infrastructure Automate and simplify management and monitoring

More information

EMC XtremSF: Delivering Next Generation Performance for Oracle Database

EMC XtremSF: Delivering Next Generation Performance for Oracle Database White Paper EMC XtremSF: Delivering Next Generation Performance for Oracle Database Abstract This white paper addresses the challenges currently facing business executives to store and process the growing

More information

Performance Validation and Test Results for Microsoft Exchange Server 2010 Enabled by EMC CLARiiON CX4-960

Performance Validation and Test Results for Microsoft Exchange Server 2010 Enabled by EMC CLARiiON CX4-960 Performance Validation and Test Results for Microsoft Exchange Server 2010 Abstract The purpose of this white paper is to profile the performance of the EMC CLARiiON CX4-960 with Microsoft Exchange Server

More information

VBLOCK SOLUTION FOR MICROSOFT EXCHANGE AND SHAREPOINT SERVERS FOR MID-SIZE AND REMOTE DATA CENTERS

VBLOCK SOLUTION FOR MICROSOFT EXCHANGE AND SHAREPOINT SERVERS FOR MID-SIZE AND REMOTE DATA CENTERS www.vce.com VBLOCK SOLUTION FOR MICROSOFT EXCHANGE AND SHAREPOINT SERVERS FOR MID-SIZE AND REMOTE DATA CENTERS Version 1.0 April 2013 2013 VCE Company, LLC. All Rights Reserved. Copyright 2013 VCE Company,

More information

Integration and Automation with Lenovo XClarity Administrator

Integration and Automation with Lenovo XClarity Administrator Integration and Automation with Lenovo XClarity Administrator Extend Management Processes to Existing Ecosystems Lenovo Enterprise Business Group April 2015 2015 Lenovo. All rights reserved. Introduction

More information

MICROSOFT EXCHANGE SERVER BEST PRACTICES AND DESIGN GUIDELINES FOR EMC STORAGE

MICROSOFT EXCHANGE SERVER BEST PRACTICES AND DESIGN GUIDELINES FOR EMC STORAGE White Paper MICROSOFT EXCHANGE SERVER BEST PRACTICES AND DESIGN GUIDELINES FOR EMC STORAGE Design best practices Sizing best practices Exchange Server performance acceleration with EMC flash technologies

More information

EMC Backup and Recovery for Microsoft SQL Server 2008 Enabled by EMC Celerra Unified Storage

EMC Backup and Recovery for Microsoft SQL Server 2008 Enabled by EMC Celerra Unified Storage EMC Backup and Recovery for Microsoft SQL Server 2008 Enabled by EMC Celerra Unified Storage Applied Technology Abstract This white paper describes various backup and recovery solutions available for SQL

More information

White Paper. SAP NetWeaver Landscape Virtualization Management on VCE Vblock System 300 Family

White Paper. SAP NetWeaver Landscape Virtualization Management on VCE Vblock System 300 Family White Paper SAP NetWeaver Landscape Virtualization Management on VCE Vblock System 300 Family Table of Contents 2 Introduction 3 A Best-of-Breed Integrated Operations Architecture 3 SAP NetWeaver Landscape

More information

EMC SYNCPLICITY FILE SYNC AND SHARE SOLUTION

EMC SYNCPLICITY FILE SYNC AND SHARE SOLUTION EMC SYNCPLICITY FILE SYNC AND SHARE SOLUTION Automated file synchronization Flexible, cloud-based administration Secure, on-premises storage EMC Solutions January 2015 Copyright 2014 EMC Corporation. All

More information

EMC STORAGE OPTIMIZATION AND HIGH AVAILABILITY FOR MICROSOFT SQL SERVER 2008 R2

EMC STORAGE OPTIMIZATION AND HIGH AVAILABILITY FOR MICROSOFT SQL SERVER 2008 R2 White Paper EMC STORAGE OPTIMIZATION AND HIGH AVAILABILITY FOR MICROSOFT SQL SERVER 2008 R2 Automate performance optimization Validate high availability options Designed for enterprise customers EMC Solutions

More information

EMC MIGRATION OF AN ORACLE DATA WAREHOUSE

EMC MIGRATION OF AN ORACLE DATA WAREHOUSE EMC MIGRATION OF AN ORACLE DATA WAREHOUSE EMC Symmetrix VMAX, Virtual Improve storage space utilization Simplify storage management with Virtual Provisioning Designed for enterprise customers EMC Solutions

More information

Microsoft Exchange 2010 on Dell Systems. Simple Distributed Configurations

Microsoft Exchange 2010 on Dell Systems. Simple Distributed Configurations Microsoft Exchange 2010 on Dell Systems Simple Distributed Configurations Global Solutions Engineering Dell Product Group Microsoft Exchange 2010 on Dell Systems Simple Distributed Configurations This

More information

MANAGING MICROSOFT SQL SERVER WORKLOADS BY SERVICE LEVELS ON EMC VMAX3

MANAGING MICROSOFT SQL SERVER WORKLOADS BY SERVICE LEVELS ON EMC VMAX3 MANAGING MICROSOFT SQL SERVER WORKLOADS BY SERVICE LEVELS ON EMC VMAX3 EMC VMAX3, Microsoft SQL Server 2014, EMC TimeFinder SnapVX Powerful mission-critical enterprise storage Simplified storage provisioning

More information

VBLOCK SOLUTION FOR MICROSOFT EXCHANGE 2010

VBLOCK SOLUTION FOR MICROSOFT EXCHANGE 2010 Vblock Solution for Microsoft Exchange 2010 Table of Contents www.vce.com Pre-VCE stle VBLOCK SOLUTION FOR MICROSOFT EXCHANGE 2010 Version 2.0 February 2013 1 Copyright 2013 VCE Company, LLC. All Rights

More information

Lab Validation Report. Leo Nguyen. Month Year

Lab Validation Report. Leo Nguyen. Month Year 1 Hitachi Compute Blade 2000, Hitachi Adaptable Modular Storage 2500, and Microsoft Exchange 2010 Management Packs Integration with Microsoft System Center Operations Manager 2007 R2 Lab Validation Report

More information

How to Backup and Restore a VM using Veeam

How to Backup and Restore a VM using Veeam How to Backup and Restore a VM using Veeam Table of Contents Introduction... 3 Assumptions... 3 Add ESXi Server... 4 Backup a VM... 6 Restore Full VM... 12 Appendix A: Install Veeam Backup & Replication

More information

DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION

DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION A DIABLO WHITE PAPER AUGUST 2014 Ricky Trigalo Director of Business Development Virtualization, Diablo Technologies

More information

HIGH AVAILABILITY CONFIGURATION FOR HEALTHCARE INTEGRATION PORTFOLIO (HIP) REGISTRY

HIGH AVAILABILITY CONFIGURATION FOR HEALTHCARE INTEGRATION PORTFOLIO (HIP) REGISTRY White Paper HIGH AVAILABILITY CONFIGURATION FOR HEALTHCARE INTEGRATION PORTFOLIO (HIP) REGISTRY EMC Documentum HIP, EMC Documentum xdb, Microsoft Windows 2012 High availability for EMC Documentum xdb Automated

More information

Optimized Storage Solution for Enterprise Scale Hyper-V Deployments

Optimized Storage Solution for Enterprise Scale Hyper-V Deployments Optimized Storage Solution for Enterprise Scale Hyper-V Deployments End-to-End Storage Solution Enabled by Sanbolic Melio FS and LaScala Software and EMC SAN Solutions Proof of Concept Published: March

More information

EMC Infrastructure for Microsoft Private Cloud

EMC Infrastructure for Microsoft Private Cloud White Paper EMC Infrastructure for Microsoft Private Cloud EMC VNX5300, Replication Manager, Microsoft Hyper-V, Microsoft Exchange, SharePoint, Optimize infrastructure performance Cloud-ready infrastructure

More information

Administration Guide for the System Center Cloud Services Process Pack

Administration Guide for the System Center Cloud Services Process Pack Administration Guide for the System Center Cloud Services Process Pack Microsoft Corporation Published: May 7, 2012 Author Kathy Vinatieri Applies To System Center Cloud Services Process Pack This document

More information

OPTIMIZING MICROSOFT EXCHANGE AND SHAREPOINT WITH EMC XTREMIO

OPTIMIZING MICROSOFT EXCHANGE AND SHAREPOINT WITH EMC XTREMIO White Paper OPTIMIZING MICROSOFT EXCHANGE AND SHAREPOINT WITH EMC XTREMIO EMC XtremIO 4.0, Microsoft Exchange Server 2013, Microsoft SharePoint Server 2013 All-flash array with optimized performance Constant

More information

EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution

EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution Release 3.0 User Guide P/N 300-999-671 REV 02 Copyright 2007-2013 EMC Corporation. All rights reserved. Published in the USA.

More information

Table of contents. Technical white paper

Table of contents. Technical white paper Technical white paper Provisioning Highly Available SQL Server Virtual Machines for the HP App Map for Database Consolidation for Microsoft SQL Server on ConvergedSystem 700x Table of contents Executive

More information

How To Connect Virtual Fibre Channel To A Virtual Box On A Hyperv Virtual Machine

How To Connect Virtual Fibre Channel To A Virtual Box On A Hyperv Virtual Machine Virtual Fibre Channel for Hyper-V Virtual Fibre Channel for Hyper-V, a new technology available in Microsoft Windows Server 2012, allows direct access to Fibre Channel (FC) shared storage by multiple guest

More information

Virtualized Exchange 2007 Archiving with EMC EmailXtender/DiskXtender to EMC Centera

Virtualized Exchange 2007 Archiving with EMC EmailXtender/DiskXtender to EMC Centera EMC Solutions for Microsoft Exchange 2007 Virtualized Exchange 2007 Archiving with EMC EmailXtender/DiskXtender to EMC Centera EMC Commercial Solutions Group Corporate Headquarters Hopkinton, MA 01748-9103

More information

Deploying Microsoft Exchange Server 2010 on the Hitachi Adaptable Modular Storage 2500

Deploying Microsoft Exchange Server 2010 on the Hitachi Adaptable Modular Storage 2500 Deploying Microsoft Exchange Server 2010 on the Hitachi Adaptable Modular Storage 2500 Reference Architecture Guide By Patricia Brailey July 2010 Summary IT administrators need email solutions that provide

More information

EMC Backup and Recovery for Microsoft Exchange 2007 SP2

EMC Backup and Recovery for Microsoft Exchange 2007 SP2 EMC Backup and Recovery for Microsoft Exchange 2007 SP2 Enabled by EMC Celerra and Microsoft Windows 2008 Copyright 2010 EMC Corporation. All rights reserved. Published February, 2010 EMC believes the

More information

Virtualized Exchange 2007 Local Continuous Replication

Virtualized Exchange 2007 Local Continuous Replication EMC Solutions for Microsoft Exchange 2007 Virtualized Exchange 2007 Local Continuous Replication EMC Commercial Solutions Group Corporate Headquarters Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com

More information

EMC MULTISITE DISASTER RECOVERY FOR MICROSOFT SQL SERVER 2012

EMC MULTISITE DISASTER RECOVERY FOR MICROSOFT SQL SERVER 2012 White Paper EMC MULTISITE DISASTER RECOVERY FOR MICROSOFT SQL SERVER 2012 EMC VNX5700, EMC FAST Cache, SQL Server AlwaysOn Availability Groups Mission-critical high availability Automated storage optimization

More information

Hitachi Unified Compute Platform (UCP) Pro for VMware vsphere

Hitachi Unified Compute Platform (UCP) Pro for VMware vsphere Test Validation Hitachi Unified Compute Platform (UCP) Pro for VMware vsphere Author:, Sr. Partner, Evaluator Group April 2013 Enabling you to make the best technology decisions 2013 Evaluator Group, Inc.

More information

Microsoft Exchange Solutions on VMware

Microsoft Exchange Solutions on VMware Design and Sizing Examples: Microsoft Exchange Solutions on VMware Page 1 of 19 Contents 1. Introduction... 3 1.1. Overview... 3 1.2. Benefits of Running Exchange Server 2007 on VMware Infrastructure 3...

More information

HBA Virtualization Technologies for Windows OS Environments

HBA Virtualization Technologies for Windows OS Environments HBA Virtualization Technologies for Windows OS Environments FC HBA Virtualization Keeping Pace with Virtualized Data Centers Executive Summary Today, Microsoft offers Virtual Server 2005 R2, a software

More information

DELL. Dell Microsoft Windows Server 2008 Hyper-V TM Reference Architecture VIRTUALIZATION SOLUTIONS ENGINEERING

DELL. Dell Microsoft Windows Server 2008 Hyper-V TM Reference Architecture VIRTUALIZATION SOLUTIONS ENGINEERING DELL Dell Microsoft Windows Server 2008 Hyper-V TM Reference Architecture VIRTUALIZATION SOLUTIONS ENGINEERING September 2008 1 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL

More information

MS Exchange Server Acceleration

MS Exchange Server Acceleration White Paper MS Exchange Server Acceleration Using virtualization to dramatically maximize user experience for Microsoft Exchange Server Allon Cohen, PhD Scott Harlin OCZ Storage Solutions, Inc. A Toshiba

More information

EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution

EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution Version 9.0 User Guide 302-001-755 REV 01 Copyright 2007-2015 EMC Corporation. All rights reserved. Published in USA. Published

More information

RELEASE NOTES. Release Notes P/N 300-012-821 REV 12. EMC Storage Integrator for Windows Suite Version 3.5. July 2014

RELEASE NOTES. Release Notes P/N 300-012-821 REV 12. EMC Storage Integrator for Windows Suite Version 3.5. July 2014 RELEASE NOTES EMC Storage Integrator for Windows Suite Version 3.5 Release Notes P/N 300-012-821 REV 12 July 2014 These release notes contain information for the following topics: Revision history... 2

More information

Managing storage in the virtual data center. A white paper on HP Storage Essentials support for VMware host virtualization

Managing storage in the virtual data center. A white paper on HP Storage Essentials support for VMware host virtualization Managing storage in the virtual data center A white paper on HP Storage Essentials support for VMware host virtualization Introduction As server virtualization technologies like VMware get deployed in

More information

VMware vsphere Data Protection 6.0

VMware vsphere Data Protection 6.0 VMware vsphere Data Protection 6.0 TECHNICAL OVERVIEW REVISED FEBRUARY 2015 Table of Contents Introduction.... 3 Architectural Overview... 4 Deployment and Configuration.... 5 Backup.... 6 Application

More information

Best Practices for Virtualised SharePoint

Best Practices for Virtualised SharePoint Best Practices for Virtualised SharePoint Brendan Law Blaw@td.com.au @FlamerNZ Flamer.co.nz/spag/ Nathan Mercer Nathan.Mercer@microsoft.com @NathanM blogs.technet.com/nmercer/ Agenda Why Virtualise? Hardware

More information

Performance characterization report for Microsoft Hyper-V R2 on HP StorageWorks P4500 SAN storage

Performance characterization report for Microsoft Hyper-V R2 on HP StorageWorks P4500 SAN storage Performance characterization report for Microsoft Hyper-V R2 on HP StorageWorks P4500 SAN storage Technical white paper Table of contents Executive summary... 2 Introduction... 2 Test methodology... 3

More information

SAN Conceptual and Design Basics

SAN Conceptual and Design Basics TECHNICAL NOTE VMware Infrastructure 3 SAN Conceptual and Design Basics VMware ESX Server can be used in conjunction with a SAN (storage area network), a specialized high speed network that connects computer

More information