Power adapter international energy efficiency standards notification: Level VI

Size: px
Start display at page:

Download "Power adapter international energy efficiency standards notification: Level VI"

Transcription

1 Power adapter international energy efficiency standards notification: Level VI Steve Taranovich - February 16, 2015 I recently had a really enlightening discussion with CUI Inc. VP of Global Marketing, Jeff Schnabel and CUI resident expert on Power adapter Level VI exports, Andrew Johnson, Product manager for external adapters. The main reason for our discussion was to help get early information out to OEMs regarding the next level in Power Adapter standards, Level VI. CUI asked EDN to assist in informing the industry groups who will need to be aware of this new level of the international standard because in previous new level announcements, so many OEMs were caught off guard and not adequately prepared. There is nothing I admire more in a company than their concern for their customers. I have seen this trait in CUI over the years in their efforts to promote power supply interoperability in the industry as well. A little history First, a little background information. Back in 1998, Alan Meier, a staff scientist at Lawrence Berkeley National Laboratory (LBNL), came up with an estimate that standby power used about 5% of the total residential electricity consumption in America alone. This equates to $3B in yearly energy costs. The U.S. Department of Energy (DOE) did an estimate of 2004 US residential electricity usage for 2004 that totaled to 1.29B megawatt hours (MWh). To waste 5% of this equates to 64 million MWh which is the amount of power that 18 typical power stations generates! In our present day world of high energy costs and dwindling energy resources, major focus has been on the efficiency of active mode power consumption, which has been improving at some tenths of a percent with each new innovation or architecture improvement. No load power consumption was almost low-hanging fruit to address in the industry, so new standards were issued by the US government to reduce annual Greenhouse gas emissions (China is a big target with their growing industry and lack of standards and so many new cars added to the road) that amounted to 198.5

2 million metric tons of CO emissions which was equal to the annual exhaust output of 39 million automobiles on the road. Now, more stringent standards, are poised to go into effect in 2016 to help consumers save the amount of electricity that 6.5 million homes use in a year. The entire world must be involved in this effort to reduce wasteful use of energy and unnecessary Carbon Emissions, otherwise it may be a futile effort. In November 2014, the Guardian reported that the US and China stuck a deal on carbon cuts in a push for a global climate change pact. In general, currently the US and Canada are adhering to Level IV and the EU to Level V. Right now, the US, Canada and the EU are the only regions in the world that mandate energy levels by law. So OEMs need to be aware of these new requirements and to follow them as they get updated to ensure compliance and avoid fines and delays is shipments and revenue. Since OEMs need to have a universal power supply platform in order for their products to ship around the world, most of the external power supply manufacturers now meet level V requirements. For more details visit the CUI website No-load mode No-load mode An external power supply is in the no-load mode when connected to an AC line but not connected to an output load. How many of us have these supplies just sitting there in a wall socket and come home to plug our devices into? I did, until I had this discussion with CUI. It is interesting that for Level IV and V, some manufacturers just shortened the DC cable to meet the standard. I wondered how the manufacturers such as CUI were going to approach meeting the standard. For this new Level VI, manufacturers will need to re-layout their board designs and work with the transformer and IC companies to meet the no-load and operating standard requirements. The approach will likely start with the IC manufacturers/designers, then the re-layout of the adapter PC board and finally work with the transformer manufacturer/designers. The following table summarizes the standard progression to date. Progressing thresholds for performance (Image courtesy of CUI)

3 Exemptions There are certain exemptions to the standard for external power supplies such as in the US for devices that require FDA approval, those devices that are a power charger of a detachable battery pack or charges the battery of a product that is fully or primarily motor operated and those devices that are available as a service part or spare part by the manufacturer of an end-product produced before 7/1/2008 for which the power supply was the primary load )Power supplies used for this purpose can be manufactured after 7/1/2008). The EU has similar exemptions so external power supplies for medical devices, battery chargers, and service products are also exempt. But, in addition, low voltage external power supplies (EPS) devices are exempt. That is, a unit that bears a nameplate output voltage of less than 6V and a nameplate current greater than or equal to 550 ma. Moving to Level VI Power supply manufacturers such as CUI are presently preparing for this upcoming Level VI standard. This next level tightens the performance thresholds for power adapters in both active and no-load operation. Additional products now covered under Level VI are multiple-voltage external supplies as well as products with power levels exceeding or equal to 250 W.

4 Summary of the new performance thresholds Summary of the new performance thresholds An external power supply with a nameplate output voltage less than 6 volts and nameplate output current greater than or equal to 550 milliamps is defined as a Low-Voltage External Ac-Dc Power Supply. Specific standards have been written into the Level VI regulations to govern these adapters. (Image courtesy of CUI) For the first time, multiple-output power supplies will be regulated under the DOE s Level VI standards. It is imperative that manufacturers start to prepare now to transition to the more stringent performance thresholds. (Image courtesy of CUI)

5 The new standard also defines power supplies as direct operation and indirect operation products. A direct operation product is an external power supply (EPS) that functions in its end product without the assistance of a battery. An indirect operation EPS is not a battery charger but cannot operate the end product without the assistance of a battery. The new standard only applies to direct operation external power supplies. Indirect operation models will still be governed by the limits as defined by EISA2007. (Image courtesy of CUI) So the compliance date is set for 2/10/2016 and the OEMs need to understand that compliance with the new standard will be regulated from the date of manufacture. Legacy products can still be shipped as long as the manufacture date is before 2/10/2016. There will be requirements on labeling to meet the same international Efficiency Marking Protocol for EPS Version 3.0 as in the current Level V standard. See the image below.

6 The international efficiency marking protocol for external power supplies is a system used by manufacturers to identify what efficiency level the supply meets. The efficiency level is marked on the supply s label by a roman numeral that corresponds to a specific efficiency level. This makes it easy for users to quickly identify the efficiency level of a particular external power supply. Current protocol is for power supply manufacturers to indicate compliance by placing a Roman Numeral based on the efficiency level on the power supply label as specified by the International Efficiency Marking Protocol for External Power Supplies Version 3.0, updated in September This latest version of the Protocol provides additional flexibility on where the marking may be placed. Going forward OEMs will need to re-test these new designs with their products especially with regard to EMI and EMC. We expect that other nations around the world will follow this new spec level. Right now in the EU, mandatory European Ecodesign Directive for EPS is being revised and will most likely meet most and hopefully all of the US standards. Other countries, including Canada and Australia, with existing efficiency regulations in line with the US will most likely move to the new standard as well. Kudos to CUI for giving me this overview to share with all of EDN s readers who may be affected by this standard or who need to be aware of progress in the industry towards higher efficiency and reducing wasteful power usage to improve our environment. It is expected that electric motors, an area of much wasted energy, will be a next potential target for more stringent standards adherence.

International External Power Supply Regulations

International External Power Supply Regulations International External Power Supply Regulations Author Revision Scott Brown, Divisional VP Marketing, Power Conversion Business Group Rev. A Release Date September 2014 Dialog Semiconductor, Inc. Power

More information

Code of Conduct on Energy Efficiency of External Power Supplies

Code of Conduct on Energy Efficiency of External Power Supplies EUROPEAN COMMISSION DIRECTORATE-GENERAL JRC JOINT RESEARCH CENTRE Institute for Energy and Transport Renewable Energy Unit Ispra, 29 October 2013 Code of Conduct on Energy Efficiency of External Power

More information

REVIEW STUDY ON COMMISSION REGULATION (EC) NO. 278/2009 EXTERNAL POWER SUPPLIES

REVIEW STUDY ON COMMISSION REGULATION (EC) NO. 278/2009 EXTERNAL POWER SUPPLIES European Commission - Directorate-General for Energy Framework Contract ENER/C3/2012-418-Lot 2 REVIEW STUDY ON COMMISSION REGULATION (EC) NO. 278/2009 EXTERNAL POWER SUPPLIES Draft Final Report Project

More information

EV Charging Standards

EV Charging Standards EV Charging Standards Professor Thomas Bräunl The University of Western Australia Technical Director WA Electric Vehicle Trial Quite a lot of progress has been made in EV charging standards over the last

More information

CELLULAR PHONES. Advancements in Energy Efficiency and Opportunities for Energy Savings

CELLULAR PHONES. Advancements in Energy Efficiency and Opportunities for Energy Savings CELLULAR PHONES Advancements in Energy Efficiency and Opportunities for Energy Savings Project Manager and Editor Noah Horowitz, Natural Resources Defense Council Authors Peter Ostendorp, Ecos Consulting

More information

Notebook Computer (including Slates and Tablets) Hewlett Packard Company 3000 Hanover Street Palo Alto, CA 94303-1112 United States of America

Notebook Computer (including Slates and Tablets) Hewlett Packard Company 3000 Hanover Street Palo Alto, CA 94303-1112 United States of America SUBJECT: Product Environmental Information Declaration DATE OF DECLARATION: 20150429 Regulatory Reference: Product Type: Manufacturer s Name: Product Model Number: Commission Regulation (EU) No. 617/2013

More information

shecco input to EC public hearing on a European strategy on clean and energy efficient vehicles

shecco input to EC public hearing on a European strategy on clean and energy efficient vehicles shecco input to EC public hearing on a European strategy on clean and energy efficient vehicles 11 march 2010 market research b2b platforms public affairs events management Brussels, 11 March 2010 In 1886,

More information

PRODUCT PROFILE BURGLAR ALARMS AUSTRALIA S STANDBY POWER STRATEGY 2002-2012

PRODUCT PROFILE BURGLAR ALARMS AUSTRALIA S STANDBY POWER STRATEGY 2002-2012 STANDBY PRODUCT PROFILE 2004/15 UPDATED NOVEMBER 2005 PRODUCT PROFILE BURGLAR ALARMS AUSTRALIA S STANDBY POWER STRATEGY 2002-2012 AN INITIATIVE OF THE MINISTERIAL COUNCIL ON ENERGY FORMING PART OF THE

More information

EGSTON Standard E2xFxWx 12W

EGSTON Standard E2xFxWx 12W General description The family of switchmode power supplies offers an unmatched degree of flexibility and performance fulfilling even the most stringent requirements. Highly flexible electrical configuration

More information

July 6, 2016. SUBJECT: Electric Vehicle (EV) and Utilities a Win-Win investment?

July 6, 2016. SUBJECT: Electric Vehicle (EV) and Utilities a Win-Win investment? Henry Lorenzen Chair Oregon Bill Bradbury Oregon Phil Rockefeller Washington Tom Karier Washington W. Bill Booth Vice Chair Idaho James Yost Idaho Pat Smith Montana Jennifer Anders Montana July 6, 2016

More information

Connection method for charging systems a key element for electric vehicles

Connection method for charging systems a key element for electric vehicles Connection method for charging systems a key element for electric vehicles By Claude Ricaud and Philippe Vollet > Abstract At the heart of the energy and environmental challenges, the electric vehicle

More information

Greening The Data Center

Greening The Data Center Greening The Data Center A Five Step Method for CIO s and Data Center Managers Professionals who manage Data Centers know what is expected from them for performance and uptime. What many are only just

More information

Desktop and Integrated Desktop Computer Product Environmental Information Declaration Form for COMMISSION REGULATION (EC) No 617/2013

Desktop and Integrated Desktop Computer Product Environmental Information Declaration Form for COMMISSION REGULATION (EC) No 617/2013 SUBJECT: Product Environmental Information Declaration DATE OF DECLARATION: 2015-03-23 Regulatory Reference: Product Type: Manufacturer s Name: Product Model Number: Commission Regulation (EU) No. 617/2013

More information

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire) FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control

More information

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres What factors determine the energy efficiency of a data centre? Where is the energy used? Local Climate Data Hall Temperatures Chiller / DX Energy Condenser / Dry Cooler / Cooling Tower Energy Pump Energy

More information

TerraWave Solutions MIMO Site Survey Battery Pack (Part # TW-SSBP-007) Instructions For Use

TerraWave Solutions MIMO Site Survey Battery Pack (Part # TW-SSBP-007) Instructions For Use Standard Shipping Contents of the TW-SSBP-007: 1 qty Site Survey Battery Pack (Diagram 1) 1 qty Charger (Diagram 2) 1 qty RJ-45 Red (802.3af) POE Cable (Diagram 3) 1 qty 2 56 Volt Power Cord (Diagram 4)

More information

Multimeter measurements on variable frequency drives using the new Fluke 289 DMM

Multimeter measurements on variable frequency drives using the new Fluke 289 DMM Multimeter measurements on variable frequency drives using the new Fluke 289 DMM Application Note Editor s note: For similar instructions using the Fluke 87V DMM, reference Fluke article 12345. In the

More information

ENERGY STAR Qualification Activity: Version 5 (through January 2011)

ENERGY STAR Qualification Activity: Version 5 (through January 2011) ENERGY STAR Computers Product Specification Discussion Document February 2011 I. Introduction The ENERGY STAR Version 5 Computer Requirements have been in effect since July 2009. EPA, in partnership with

More information

Information & Communications Technology

Information & Communications Technology Introduction to the module These questions are designed to apply to companies operating in the Information Technology and Telecommunications GICS categories. Other companies who feel that this module is

More information

Energy efficiency requirements for charging technology

Energy efficiency requirements for charging technology Energy efficiency requirements for charging technology By Arno Reinhard Compliance with energy efficiency standards plays an increasingly important role for electronics. Statutory requirements for "pure"

More information

The Manufacturer Perspective

The Manufacturer Perspective Workshop on ENERGY STAR Electronics Program Design September 24, 2008 Long Beach, CA The Manufacturer Perspective Doug Johnson Sr. Director, Technology Policy & International Affairs Consumer Electronics

More information

Conserve Valet Smart USB Charging Station. User Guide

Conserve Valet Smart USB Charging Station. User Guide Conserve Valet Smart USB Charging Station User Guide A charger left plugged into the wall can still draw power even when no device is attached. The Conserve Valet Smart USB Charging Station charges up

More information

Electric Vehicles: Driving EVolution

Electric Vehicles: Driving EVolution Electric Vehicles: Driving EVolution November 2014 Executive Summary Electric Vehicles (EVs) have the potential to provide a significant benefit to consumers and utilities, however as demonstrated in Ergon

More information

Torfino Enterprises, Inc.

Torfino Enterprises, Inc. Torfino Enterprises, Inc. An independent study of commercially available 9 volt rechargeable battery technology for implementation and use with the ICE LIGHT & METAL-TEC 1400 Product line Written By: Nicholas

More information

Measuring Electricity Class Activity

Measuring Electricity Class Activity Measuring Electricity Class Activity Objective: To understand what energy is, how it impacts our daily lives, and how one can become an energy steward. Learning Outcomes: Students will: 1. Understand where

More information

Understanding and Measuring School Electronics

Understanding and Measuring School Electronics Understanding and Measuring School Electronics MATERIALS NEEDED: 1. 6 energy monitoring devices (note: these can be obtained from a variety of sources, i.e., local hardware stores, internet [average cost

More information

I = V/r P = VI. I = P/V = 100 W / 6 V = 16.66 amps. What would happen if you use a 12-volt battery and a 12-volt light bulb to get 100 watts of power?

I = V/r P = VI. I = P/V = 100 W / 6 V = 16.66 amps. What would happen if you use a 12-volt battery and a 12-volt light bulb to get 100 watts of power? Volts, Amps and Ohms Measuring Electricity The three most basic units in electricity are voltage (V), current (I) and resistance (r). Voltage is measured in volts, current is measured in amps and resistance

More information

Revolutionizing EV HVAC Energy Use with Heat Pumps

Revolutionizing EV HVAC Energy Use with Heat Pumps Revolutionizing EV HVAC Energy Use with Heat Pumps Air conditioning for automobiles is a big energy consumer. In fact in the US, automobiles burn 170 million barrels of oil annually equivalent to 5.5%

More information

13 Watt PORTABLE SOLAR POWER KIT

13 Watt PORTABLE SOLAR POWER KIT 3 Watt PORTABLE SOLAR POWER KIT User s Manual Thank you for purchasing a Sunforce Portable Solar Power Kit. Please read these instructions carefully and thoroughly before using the product. Your new Portable

More information

Product brochure. EV Charging Infrastructure ABB global charging portfolio

Product brochure. EV Charging Infrastructure ABB global charging portfolio Product brochure EV Charging Infrastructure ABB global charging portfolio ABB is global leader in EV charging Supporting all EV charging standards ABB is leading with Internet-connected charging infrastructure,

More information

European Distribution System Operators for Smart Grids. Position paper on Electric Vehicles Charging Infrastructure

European Distribution System Operators for Smart Grids. Position paper on Electric Vehicles Charging Infrastructure European Distribution System Operators for Smart Grids Position paper on Electric Vehicles Charging Infrastructure European Distribution System Operators for Smart Grids Position paper on ELECTRIC VEHICLES

More information

FIRST ANNOUNCEMENT AND CALL FOR ABSTRACTS. 7th International Conference on Energy Efficiency in Domestic Appliances and Lighting (EEDAL 13)

FIRST ANNOUNCEMENT AND CALL FOR ABSTRACTS. 7th International Conference on Energy Efficiency in Domestic Appliances and Lighting (EEDAL 13) FIRST ANNOUNCEMENT AND CALL FOR ABSTRACTS 7th International Conference on Energy Efficiency in Domestic Appliances and Lighting (EEDAL 13) 11-13 September 2013 Coimbra, Portugal Introduction Citizens and

More information

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN By Joe Randolph Introduction The conventional 2-wire analog phone line that telephone companies provide to residential

More information

Energy Efficient High-tech Buildings

Energy Efficient High-tech Buildings Energy Efficient High-tech Buildings Can anything be done to improve Data Center and Cleanroom energy efficiency? Bill Tschudi Lawrence Berkeley National Laboratory Wftschudi@lbl.gov Acknowledgements California

More information

Guide to the China Compulsory Certification System December 2009 OMRON Corporation Industrial Automation Company

Guide to the China Compulsory Certification System December 2009 OMRON Corporation Industrial Automation Company Guide to the China Compulsory Certification System December 2009 OMRON Corporation Industrial Automation Company -1- Contents Page 1. What Is CCC? 3 2. Procedure for Judging If a Product Is Subject to

More information

Making power plants energy efficient

Making power plants energy efficient Making power plants energy efficient The Italian utility Enel has transformed its Torrevaldaliga Nord thermal power plant from heavy fuel to clean coal with the help of ABB power and automation technologies,

More information

DOE Data Center Energy Efficiency Program

DOE Data Center Energy Efficiency Program DOE Data Center Energy Efficiency Program Paul Scheihing U.S. Department of Energy Energy Efficiency and Renewable Energy April 2009 1 DOE Industrial Technologies Program Worki king to improve th e energy

More information

Information & Communications Technology

Information & Communications Technology Introduction to the module These questions are designed to apply to companies operating in the Inmation Technology and Telecommunications sector. Other companies who feel that this module is relevant them

More information

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Energy usage in the data center Electricity Transformer/ UPS Air 10% Movement 12% Cooling 25% Lighting, etc. 3% IT Equipment

More information

THE ErP DIRECTIVE 2009/125/EC KEY FACTS» REGULATIONS 327/2011 640/2009. ErP. www.flaktwoods.co.uk/erp - Version 2.0

THE ErP DIRECTIVE 2009/125/EC KEY FACTS» REGULATIONS 327/2011 640/2009. ErP. www.flaktwoods.co.uk/erp - Version 2.0 THE DIRECTIVE 2009/125/EC KEY FACTS» REGULATIONS 327/2011 640/2009 www.flaktwoods.co.uk/erp - Version 2.0 2 OBJECTIVES KEY POINTS DIRECTIVE - KEY POINTS DIRECTIVE - OBJECTIVES stands for Energy related

More information

PRODUCT LIST Facility DDC Access WebXL DDC

PRODUCT LIST Facility DDC Access WebXL DDC PRODUCT LIST Facility DDC Access WebXL DDC Effective from 01/10/2014 Sphere Systems Pty Ltd Unit 6 / 9 Mirra Crt Bundoora Victoria Australia 3083 ABN 98 006 579 004 Phone +61 3 9470 8844 Fax +61 3 9470

More information

Radiometrics Guide to FCC & Canada Compliance. for Unintentional Radiators

Radiometrics Guide to FCC & Canada Compliance. for Unintentional Radiators Radiometrics Guide to FCC & Canada Compliance for Unintentional Radiators Since 1934, the FCC has had the authority to regulate the electromagnetic emissions from electronic devices. Since October 1, 1983,

More information

Analysis of a 30 Percent by 2030 National Renewable Electricity Standard

Analysis of a 30 Percent by 2030 National Renewable Electricity Standard Analysis of a 30 Percent by 2030 National Renewable Electricity Standard Alison Bailie, Steve Clemmer, and Jeff Deyette May 12, 2015 Photo: istock 2015 Union of Concerned Scientists www.ucsusa.org/30by2030nationalres.pdf

More information

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger The Nucleus Freedom BTE Rechargeable Battery (A25) is designed for use with your Nucleus Freedom BTE Controller (3 Zinc

More information

WORKSHOP: The roles of wood in green building and green building effects on the forest sector of in the UNECE region.

WORKSHOP: The roles of wood in green building and green building effects on the forest sector of in the UNECE region. WORKSHOP: The roles of wood in green building and green building effects on the forest sector of in the UNECE region. Are ENGO s ready to promote the use of wood as the preferred building material? Alison

More information

30 In Compliance October 2014 www.incompliancemag.com

30 In Compliance October 2014 www.incompliancemag.com 30 In Compliance October 2014 www.incompliancemag.com Medical Devices in a Wireless World BY IVAYLO TANKOV While wireless technology is now an integral component of a wide variety of manufactured products,

More information

The Importance of Energy Labelling and MEPS Programs

The Importance of Energy Labelling and MEPS Programs Towards a global framework for energy efficiency metrics by Lloyd Harrington Energy Presentation to ECEEE Forum October 2006, Brussels Overview The concept of energy efficiency How could we define common

More information

Models HP 230W Smart AC Adapter. HP 40W Smart AC Adapter (H5W93AA) HP 65W Smart AC Adapter (ED494AA) HP 90W Smart AC Adapter (ED495AA)

Models HP 230W Smart AC Adapter. HP 40W Smart AC Adapter (H5W93AA) HP 65W Smart AC Adapter (ED494AA) HP 90W Smart AC Adapter (ED495AA) Overview Models HP 40W Smart AC Adapter HP 45W Smart AC Adapter HP 65W Smart AC Adapter HP 90W Smart AC Adapter HP 230W Smart AC Adapter HP 65W Slim Adapter HP 90W Slim Adapter HP 150W Slim Adapter HP

More information

Management of electric vehicle fleet charging

Management of electric vehicle fleet charging Management of electric vehicle fleet charging March 2011 / White paper by Maël Cazals and Gilles Vidalenche Make the most of your energy SM Revision #1 Contents Introduction... p 3 What is an electric

More information

AXIS 5810 A Bluetooth Print Plug. Quick Start

AXIS 5810 A Bluetooth Print Plug. Quick Start AXIS 5810 AXIS 5810 A Bluetooth Print Plug Quick Start BLUETOOTH is a trademark owned by its proprietor and used by Axis Communications AB under license 1 AXIS 5810 Regulatory Information Regulatory Information

More information

Comparing the Carbon Footprints of 11G and 12G Rack Servers from Dell

Comparing the Carbon Footprints of 11G and 12G Rack Servers from Dell Comparing the Carbon Footprints of 11G and 12G Rack Servers from Dell Markus Stutz, Regulatory Principal Engineer, Environmental Affairs August 2013. Contents Comparing two rack server generations... 4

More information

HEAVY-DUTY ON-ROAD VEHICLE INSPECTION AND MAINTENANCE PROGRAM

HEAVY-DUTY ON-ROAD VEHICLE INSPECTION AND MAINTENANCE PROGRAM HEAVY-DUTY ON-ROAD VEHICLE INSPECTION AND MAINTENANCE PROGRAM I. OBJECTIVE The objective of this study is to develop, evaluate, and assess the cost-effectiveness and economic impacts of alternatives for

More information

The Energy Savings and Emission Reduction Benefits Delivered by the State of Maryland Energy Performance Contracts

The Energy Savings and Emission Reduction Benefits Delivered by the State of Maryland Energy Performance Contracts The Energy Savings and Emission Reduction Benefits Delivered by the State of Maryland Energy Performance Contracts A Cleaner and Greener SM Environment Program Report by Leonardo Academy Inc. January 2002

More information

Management of electric vehicle fleet charging

Management of electric vehicle fleet charging Management of electric vehicle fleet charging March 2011 / White paper by Maël Cazals and Gilles Vidalenche Make the most of your energy Table of contents Introduction... p 2 What is an electric vehicle?...

More information

47000 SERIES - ELECTRONIC TRANSFORMERS

47000 SERIES - ELECTRONIC TRANSFORMERS 7000 SERIES - ELECTRONIC TRANSFORMERS MYRRA encapsulated electronic transformers are Switched Mode Power Supplies based on Flyback topology. They constitute an interesting alternative to the traditional

More information

Uninterruptible Power Supply Product Regulations and Standardization in the European Union. By Matteo Tricarico Patents and Regulatory Engineer

Uninterruptible Power Supply Product Regulations and Standardization in the European Union. By Matteo Tricarico Patents and Regulatory Engineer Uninterruptible Power Supply Product Regulations and Standardization in the European Union By Matteo Tricarico Patents and Regulatory Engineer Abstract The Uninterruptible Power Supply (UPS) design falls

More information

The Energy Independence and Security Act of 2007. The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010

The Energy Independence and Security Act of 2007. The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010 The Energy Independence and Security Act of 2007 The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010 January 23, 2009 To Our Customers, Baldor Electric Company 5711 R.S.

More information

Twenty-ninth Meeting of the Business Facilitation Advisory Committee

Twenty-ninth Meeting of the Business Facilitation Advisory Committee BFAC Paper 4/15 Twenty-ninth Meeting of the Business Facilitation Advisory Committee Agenda Item 2 : Implementation of the Revised Code of Practice on Energy Labelling of Products under the Mandatory Energy

More information

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage Description Supports DALI interface driver Programming Supports 0-10V Programmable Driver Programming Supports Other Controllers (TDD-ANPNx, SDD-AAPNx) Off-line programming capability Auto programming

More information

Smart Cities. Smart partners in tomorrow s cities

Smart Cities. Smart partners in tomorrow s cities DNV KEMA serving the energy industry Smart Cities Smart partners in tomorrow s cities Experience, knowledge and advanced methods & tools for smart city planning and implementation 02 I DNV KEMA SERVING

More information

How Small Devices are Having a Big Impact on U.S. Utility Bills

How Small Devices are Having a Big Impact on U.S. Utility Bills Andrew Fanara, U.S. EPA Robin Clark, ICF International Rebecca Duff, ICF International Mehernaz Polad, ICF International Abstract Energy consumption attributed to electronic devices in the typical U.S.

More information

CANADIAN STANDARDS ASSOCIATION OPERATING AS CSA GROUP 178 REXDALE BOULEVARD TORONTO, ONTARIO M9W 1R3 CANADA

CANADIAN STANDARDS ASSOCIATION OPERATING AS CSA GROUP 178 REXDALE BOULEVARD TORONTO, ONTARIO M9W 1R3 CANADA This is to attest that CANADIAN STANDARDS ASSOCIATION OPERATING AS CSA GROUP 178 REXDALE BOULEVARD TORONTO, ONTARIO M9W 1R3 CANADA Testing Laboratory TL-218 has met the requirements of the IAS Accreditation

More information

Runtastic rechargeable battery for iphone 4, 4S

Runtastic rechargeable battery for iphone 4, 4S Runtastic rechargeable battery for iphone 4, 4S Thank you very much for purchasing our product, the runtastic rechargeable battery (model no.: RUNBATT1) for the iphone 4. This product is only to be used

More information

Odyssey of the Mind Technology Fair. Simple Electronics

Odyssey of the Mind Technology Fair. Simple Electronics Simple Electronics 1. Terms volts, amps, ohms, watts, positive, negative, AC, DC 2. Matching voltages a. Series vs. parallel 3. Battery capacity 4. Simple electronic circuit light bulb 5. Chose the right

More information

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co.,

More information

Growing Optical Fiber Deployment Drives Demand for Semiconductors in Copper-Based Telephony

Growing Optical Fiber Deployment Drives Demand for Semiconductors in Copper-Based Telephony Growing Optical Fiber Deployment Drives Demand for Semiconductors in Copper-Based Telephony Wireline telephony may seem like old technology, having been around for more than 100 years, but it is still

More information

Mixing Sodium and Lead Battery Technologies in Telecom Applications

Mixing Sodium and Lead Battery Technologies in Telecom Applications Mixing Sodium and Lead Battery Technologies in Telecom Applications Paul Smith Shanon Kolasienski Technical Marketing Manager Application Engineer GE Critical Power GE Energy Storage Plano, TX 75074 Schenectady,

More information

City of Toronto Electric Vehicle Working Group

City of Toronto Electric Vehicle Working Group City of Toronto Electric Vehicle Working Group Mobilizing Internally to Develop EV Friendly Policies and Programs for City of Toronto Residents and Businesses By: Cecilia Fernandez, Research Analyst Toronto

More information

Public Overview of the EMerge Alliance Data/Telecom Center Standard Version 1.0

Public Overview of the EMerge Alliance Data/Telecom Center Standard Version 1.0 of the EMerge Alliance Data/Telecom Center Standard Version 1.0 A standard defining low voltage dc power distribution system requirements for use in data centers and telecom central offices Excerpted With

More information

Making power plants energy efficient ABB, integrated power and automation solutions

Making power plants energy efficient ABB, integrated power and automation solutions Making power plants energy efficient ABB, integrated power and automation solutions Making power plants energy efficient ABB has a singularly broad and comprehensive offering in power generation. It covers

More information

MN1010 Evaluation Kit v3 User Guide

MN1010 Evaluation Kit v3 User Guide 1 Evaluation Kit Introduction The MN1010 Evaluation Kit is designed to allow the user to quickly evaluate the Micro Modular Technologies MN1010 GPS receiver module. This kit can be used in either a laboratory

More information

Combi B Alarm box. Mounting instructions

Combi B Alarm box. Mounting instructions Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power

More information

GSM ATT Modules Simply effective remote control

GSM ATT Modules Simply effective remote control GSM ATT Modules Simply effective remote control To control electrical loads via mobile phone The benefits Remote management of electrical devices is an increasingly widespread requirement in residential

More information

How To Get A Power Meter From The Power Meter

How To Get A Power Meter From The Power Meter ENERGY STAR Program Requirements for Displays Table of Contents Partner Commitments... 2 Commitment... 2 Performance for Special Distinction... 3 Eligibility Criteria... 5 1) Definitions... 5 2) Qualifying

More information

Test procedures and protocols standardisation and international harmonisation

Test procedures and protocols standardisation and international harmonisation Session 7: Measuring networked standby power consumption* Test procedures and protocols standardisation and international harmonisation Bruce Nordman, LBNL, US Lloyd Harrington, EES, AU *Actually, network

More information

Thinking of switching to an electric vehicle?

Thinking of switching to an electric vehicle? What is Travel SMART? Travel SMART is an initiative from Surrey County Council that aims to help Surrey residents and businesses reduce carbon, calories and cost. The Travel SMART team want to encourage

More information

ECO-FRIENDLY COMPUTING: GREEN COMPUTING

ECO-FRIENDLY COMPUTING: GREEN COMPUTING ECO-FRIENDLY COMPUTING: GREEN COMPUTING Er. Navdeep Kochhar 1, Er. Arun Garg 2 1-2 Baba Farid College, Bathinda, Punjab ABSTRACT Cloud Computing provides the provision of computational resources on demand

More information

The Efficiency Challenge

The Efficiency Challenge The Efficiency Challenge Balancing Total Cost of Ownership with Real Estate Demands written by: Mike Wagner VP & GM Embedded Power AC-DC The Efficiency Challenge Balancing Total Cost of Ownership with

More information

Korea Green Car Fuel Economy Schemes; Status and Prospect

Korea Green Car Fuel Economy Schemes; Status and Prospect Korea Green Car Fuel Economy Schemes; Status and Prospect 18 Oct. 2013 Kyung Wan RHO KOREA ENERGY MANAGEMENT CORPORATION Contents I. Overview of Korea Fuel Economy Scheme II. Green Car Policy & Tax Incentive

More information

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit

More information

Reducing CO2 emissions for Offshore oil and gas Operations under ETS. Margaret Christie, Environmental Advisor, UK Business Unit, Premier Oil UK Ltd

Reducing CO2 emissions for Offshore oil and gas Operations under ETS. Margaret Christie, Environmental Advisor, UK Business Unit, Premier Oil UK Ltd Reducing CO2 emissions for Offshore oil and gas Operations under ETS Margaret Christie, Environmental Advisor, UK Business Unit, Premier Oil UK Ltd Reducing CO2 emissions for Offshore operations under

More information

Electric Vehicle Charging Solutions

Electric Vehicle Charging Solutions GE Energy Industrial Solutions Electric Vehicle Charging Solutions GE imagination at work The Electric Vehicle Picks up Speed Moving Power from the Grid to the Road Over the next five years, virtually

More information

New EU Legislation on F- Gases

New EU Legislation on F- Gases New EU Legislation on F- Gases motivation, objectives, impacts, innovation Arno Kaschl European Commission DG Climate Action Tel Aviv 31 March 2014 Climate Action Relevance of fluorinated gases (F-gases)

More information

computer radio control system

computer radio control system extended serie Receivers 1 Introduction GLISH FW. ver. 3.10 Jeti DUPLEX Receivers are designated for use with the DC/DS transmitters or the JETI transmitter modules in the 2,4 GHz frequency band. DUPLEX

More information

Interconnection Application For Residential and Commercial Power Systems 10 kw or Smaller

Interconnection Application For Residential and Commercial Power Systems 10 kw or Smaller Interconnection Application For Residential and Commercial Power Systems 10 kw or Smaller A fee of $0.00 must accompany this application Date: Section 1: Customer Information Section 2: Engineering firm

More information

COMPUTER SETUP GUIDE LAPTOP

COMPUTER SETUP GUIDE LAPTOP COMPUTER SETUP GUIDE LAPTOP HARDWARE SET UP Please allow seven business days for all computer equipment to arrive. In some cases, components may be shipped in multiple boxes and may arrive on different

More information

Energy Benchmarking Report for Lafayette Elementary School Bound Brook, NJ

Energy Benchmarking Report for Lafayette Elementary School Bound Brook, NJ Energy Benchmarking Report for Lafayette Elementary School Bound Brook, NJ (for the period: March 2007 through February 2009) Prepared by: Background & Findings The New Jersey Clean Energy Program (NJCEP)

More information

Green IT Solutions From Desktop to Datacenter. Dave Spear Sr. Engagement Manager & Sustainability Advocate dave.spear@microsoft.

Green IT Solutions From Desktop to Datacenter. Dave Spear Sr. Engagement Manager & Sustainability Advocate dave.spear@microsoft. Green IT Solutions From Desktop to Datacenter Dave Spear Sr. Engagement Manager & Sustainability Advocate dave.spear@microsoft.com Agenda Our Commitment Today s Environment PC, Server, Storage Computerworld

More information

Conserve Insight Energy Use Monitor. User Guide

Conserve Insight Energy Use Monitor. User Guide Conserve Insight Energy Use Monitor User Guide Find out how much energy your devices really use including watts, the cost of operation, and the amount of carbon dioxide (CO 2 ) produced in generating the

More information

for Energy Efficiency Parminder Sandhu, P. Eng

for Energy Efficiency Parminder Sandhu, P. Eng Certifying Manufacturing Plants for Energy Efficiency Parminder Sandhu, P. Eng Strategic Goals of Plant Certification Fosters an organizational culture of continuous improvement in energy efficiency i

More information

USB Plus+ RFID Reader Setup Guide

USB Plus+ RFID Reader Setup Guide 875-0042-03 RevA USB Plus+ RFID Reader Setup Guide 1 Government Limited Rights Notice: All documentation and manuals were developed at private expense and no part of it was developed using Government funds.

More information

San Francisco Chapter. Deborah Grove, Principal Grove-Associates

San Francisco Chapter. Deborah Grove, Principal Grove-Associates Deborah Grove, Principal Grove-Associates Why Green IT is Important 1. The energy consumed by servers in the US (and associated air -conditioning) is equivalent to the annual output of about 20 new coal-fired

More information

ELECTRIC VEHICLE CHARGING SOLUTIONS FOR FLEETS

ELECTRIC VEHICLE CHARGING SOLUTIONS FOR FLEETS ELECTRIC VEHICLE CHARGING SOLUTIONS FOR FLEETS Plug-in electric vehicles or EVs are ideal for fleet managers for numerous reasons: they are more energy efficient; they are less costly to operate and require

More information

TABLE OF CONTENTS. TABLE OF CONTENTS... 1 Package content... 1. INTRODUCTION Dear customer... 2 Features... 2 Caution... 2

TABLE OF CONTENTS. TABLE OF CONTENTS... 1 Package content... 1. INTRODUCTION Dear customer... 2 Features... 2 Caution... 2 Headset Englisch 19.07.2001 14:26 Uhr Seite 1 TABLE OF CONTENTS 1 TABLE OF CONTENTS............................................................... 1 Package content..................................................................

More information

Electrical Systems. <Presenter>

Electrical Systems. <Presenter> Review Root Causes of Energy Inefficiency Roadmap to Maximize Energy Efficiency Best Practices Alternative Energy Sources Controls Take Aways Seek Professional Help. ENERGY INEFFICIENCY OF

More information

MN3310 Evaluation Kit v1 User Guide

MN3310 Evaluation Kit v1 User Guide 1 Evaluation Kit Introduction The MN3310 Evaluation Kit is designed to allow the user to quickly evaluate the Micro Modular Technologies MN3310 GPS receiver module. The evaluation kit can be used in either

More information

Montenegrin Road Towards Carbon Neutral Tourism

Montenegrin Road Towards Carbon Neutral Tourism The New Green Age: Montenegrin Road Towards Carbon Neutral Tourism Ms. Jelena Janjusevic, PhD Manager of the Centre for Sustainable Development, UNDP SUSTAINABLE AND COMPETITIVE HOTELS THROUGH ENERGY INNOVATION

More information

Cisco Nexus 7000 Series Power Supply Modules

Cisco Nexus 7000 Series Power Supply Modules Cisco Nexus 7000 Series Power Supply Modules Product Overview The Cisco Nexus 7000 Series Power Supply Modules (Figures 1 and 2) deliver fault tolerance, high efficiency, load sharing, and hot-swappable

More information

Increasing Energ y Efficiency In Data Centers

Increasing Energ y Efficiency In Data Centers The following article was published in ASHRAE Journal, December 2007. Copyright 2007 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational purposes

More information

Focus. Impact of the

Focus. Impact of the Focus Impact of the Energy-using Products (EuP) Directive on SMEs In recent years, the European Union (EU) has tightened its environmental regulations on imported products. The Industrialist reports the

More information