Preparation. Sample. Solid Phase Extraction (SPE) SPE Vacuum Manifolds SUPELCO
|
|
|
- Cameron Summers
- 9 years ago
- Views:
Transcription
1 64 Solid Phase Extraction (SPE) SPE Vacuum s Visiprep SPE Vacuum s Visiprep Solid Phase Extraction Vacuum s allow you to simultaneously process up to 2 or up to 24 SPE tubes. Precise flow control is provided through each SPE tube by rotating the independent, screw-type valves in the cover. This precise control ensures the packing will not dry out in some tubes while others finish draining. A solvent-resistant vacuum bleed gauge and valve offer better sealing and vacuum control, via a screw-type mechanism fitted with a Teflon seal. The stand-alone cover with legs prevents the Teflon solvent guides from resting on the work surface and becoming damaged or contaminated. The glass basin will not dissolve, fog, or discolor when exposed to solvents, and an optional polypropylene splash guard inserts into the basin to eliminate splashing. The polypropylene collection vessel rack accommodates autosampler vials, small scintillation vials, 0mm and 6mm test tubes, and ml, 2mL, 5mL, and 0mL volumetric flasks. An optional plate for the 2-port model enables you to collect samples in up to ten 20mL scintillation vials. A Visiprep DL (Disposable Liner) Solid Phase Extraction Vacuum eliminates the possibility of contamination from one sample to the next in the same manifold port. A disposable Teflon solvent guide runs through each flow control valve. The guide acts as a liner, ensuring that all surfaces that come in contact with the sample can be replaced following each extraction. The guide consists of two parts: a polypropylene luer hub which attaches to the SPE tube and the thin-walled length of Teflon tubing that acts as the liner/solvent guide. The luer hub fits snugly into a matching slot on the flow control valve stem. As the SPE tube is rotated, the valve pinches or releases the liner, stopping or starting flow. Includes 00 liners. VISIPREP SOLID PHASE EXTRACTION MANIFOLD 2-Port Model U 24-Port Model U VISIPREP DL (DISPOSABLE LINER) SPE VACUUM MANIFOLD 2-Port Model Port Model Long Stem Flow Control Valves Equip alternate valves in your 2-port or 24-port Visiprep vacuum manifold with these long stem flow control valves if you intend to use all ports of the manifold with 2mL, 20mL, or 60mL tubes. Not for use with DL manifolds. Long stem flow control valves (pk. of 6) U U 24-Port Visiprep Vacuum 2-Port Visiprep Vacuum 2-Port Visiprep DL (Disposable Liner) Vacuum P00029 P00030 P000844
2 Solid Phase Extraction (SPE) SPE Vacuum s 65 Chemicalresistant Cover 5760-U PlatePrep Vacuum P The PlatePrep vacuum manifold consists of a clear acrylic top allowing for easier inspection of flow rates during SPE 96-well plate processing. The polypropylene base offers excellent chemical resistance while a single remote vacuum gauge/bleed valve controls flow through all the wells. Use this compact vacuum manifold in conjunction with a Discovery SPE 96-well plate to process up to 96 samples concurrently. The single valve control, parallel processing capabilities, and uniform flow dynamics allow for easier method development, reduces clutter, and allow for greater reproducibility. Unused wells can be covered and used at a later date. Starter Kit Includes: PlatePrep Vacuum 96 Sq. Well Collection Plate, 2mL, PP 2 Disposable Reservoir/Waste Trays, PVC 96 Sq. Well Piercable Cap Mat 5 Reagent Reservoirs Cluster Tube Rack DESCRIPTION QTY. CAT. NO. PRICE Supelco PlatePrep Vacuum 5792-U 96-Well Plate Starter Kit with PlatePrep U PLATEPREP VACUUM MANIFOLD REPLACEMENT PARTS Acrylic Clear Top 5793-U Polypropylene Base 5794-U Gasket/Connector Replacement Kit 5795-U Remote Vacuum Gauge/ Bleed Valve Assembly 576-U 96-WELL SPE ACCESSORY ITEMS 96 Sq. Well Collection Plates, 0.35mL, PP U 96 Sq. Well Collection Plates, ml, PP U 96 Sq. Well Collection Plates, 2mL, PP U Disposable Reservoir/ Waste Tray, PVC U 96 Sq. Well Piercable Cap Mats U Reagent Reservoirs 00 R EA Cluster Tube Rack Z PAK Supelco Preppy Vacuum Glass Basin Rotate Knurled Knob for Slow Flow Solvent Packing Bed P00028 The Preppy manifold is our simplest and most economical manifold. It too enables the analyst to simultaneously prepare up to 2 samples. It consists of a chemical-resistant cover and gasket, a glass basin, a vacuum release vent, 2 individual control valves with knurled tops, and stainless steel solvent guide needles. Two optional collection racks are available; one holds both and 4mL autosampler vials, and the other holds 2 or 20mL vials. An optional vacuum gauge/bleed valve assembly can be installed to allow precise control of the vacuum used with the Preppy manifold. PREPPY VACUUM MANIFOLD 2-Port Model 5760-U PREPPY REPLACEMENT PARTS Cover with flow control valves and solvent needle guides 5758-U COLLECTION VESSEL RACKS For or 4mL vials 5759-U For 5 or 20mL vials 5762-U ACCESSORIES Vacuum Gauge/Bleed Valve Assembly 576-U Single SPE Tube Processor Visi- processor provides two rates of flow control Our Visi- Single SPE Tube Processor provides precise flow control through a single ml, 3mL, or 6mL SPE tube. There is no faster, more convenient, or more reliable method for processing one or a few samples. Simply fill the SPE tube with the appropriate solution, attach it to the Visi- processor, and rotate the knurled knob clockwise. The solution will pass through the tube in a slow, uniform rate, consistent with the most reproducible results for SPE. Use the plunger to expel the last drop of Depress Plunger for Rapid Flow solvent from the tip of the tube. Remove the tube from the processor, introduce the next solution, and repeat the process. Visi- Single SPE Tube Processor U
3 66 Solid Phase Extraction (SPE) Vacuum Accessories Replacement Parts and Optional Components for Visiprep s FOR 2-PORT MANIFOLD Cover, 2 flow control valves, gasket 5703-U Cover, 2 DL flow control valves, gasket Gaskets (pk. of 2) Glass basin Glass basin, vacuum gauge and bleed valve Collection rack (base, 3 support rods, center plate, 0mm test tube plate, 2 retaining clips) Plate for /2/5/0mL volumetric flasks Plate for 6mm test tubes Plate for 2mL autosampler vials U Plate for 20mL scintillation vials Splash guard U FOR 24-PORT MANIFOLD Cover, 24 flow control valves, gasket Cover, 24 DL flow control valves, gasket Gaskets (pk. of 2) Glass basin Glass basin, vacuum gauge and bleed valve Collection rack (base, 2 support rods, center plate, 0mm test tube plate, 8 retaining clips) Plate for 6mm test tubes Plate for 2mL autosampler vials FOR 2-PORT OR 24-PORT MANIFOLD Flow control valves (pk. of 2) Solvent guide needles, Teflon (pk. of 2), Solvent guide needles, stainless steel (pk. of 2) Disposable liner flow control valves (pk. of 2) Liner guide needles, stainless steel (pk. of 2) 2, Disposable valve liners, Teflon (pk. of 00) 2, Vacuum gauge and bleed valve U Retaining clips for collection racks (pk. of 2) 5704 Test tubes, 0 x 75mm (pk. of 2),2,8, Included with U 2 Included with Included with U and Included with U 5 Included with Included with U and For U and U 8 2 packages included with U 9 For and packages included with P00035, P
4 Solid Phase Extraction (SPE) Vacuum Accessories 67 Drying Your Tube Packing Gas Flow Path Visidry Drying Attachment Evaporating Your Collected Gas Flow Path 5724 Tube Adapters Lid Packing in tube is dried with an inert gas. Components in collection vessel (liquid evaporated) Visidry Drying Attachment The Visidry Drying Attachment was designed for our Visiprep Vacuum (Cat. No U also fits our economical Preppy manifold). The Visidry unit installs in minutes, dries up to 2 or up to 24 SPE tubes at one time, and can be used with any inert gas supply. It is also useful for evaporating and concentrating recovered samples. Gas flow to each port can be independently adjusted. NOTE: The Visidry drying attachment cannot be used to dry 2mL, 20mL, or 60mL SPE tubes. VISIDRY DRYING ATTACHMENT 2-Port Model 5700-U 24-Port Model 5724 REPLACEMENT PARTS FOR VISIDRY DRYING ATTACHMENT Control knobs (pk. of 2) Retaining C clips (pk. of 2) Female luer plugs (pk. of 2) G000365,6 Collection Vessel Rack in P Port Model 2-Port Model U (order separately) 5700-U Long Stem Flow Control Knobs If you have equipped your Visiprep Vacuum with long stem flow control valves, these control knobs will enable you to attach the Visidry Drying Attachment without removing the long stem valves. NOTE: These knobs cannot be used with a 24-port manifold being used to process 2mL, 20mL, or 60mL tubes. Long Stem Flow Control Knobs (pk. of 6) P00020 P0000
5 68 Solid Phase Extraction (SPE) Vacuum Accessories Visiprep Large Volume rs for Direct Extraction For continuous hands off direct transfer of multiple liquid samples A Visiprep large volume sampler enables you to transfer low viscosity samples directly from any sample container to conventional solid phase extraction tubes on a Visiprep SPE vacuum manifold. Two samplers are available. One sampler has three tube adapters compatible with 2mL, 20mL, or 60mL polypropylene SPE tubes. Simultaneous extraction of 2 samples on a 2-port Visiprep manifold requires four of these samplers. The other sampler has four tube adapters for 3mL or 6mL SPE tubes. To simultaneously extract 2 samples, three samplers are required. The samplers consist of /8-inch Teflon tubing with a screw fitting at one end and a stainless steel weight at the other end. To use the sampler, feed the weighted end into a sample container until it touches the bottom. Insert the tube adapters into the conditioned SPE tubes on your Visiprep manifold. Turn on the vacuum to the Visiprep manifold and open the manifold flow control valves, and the samples will be delivered to the SPE tubes. The flow rate of sample through each tube can be independently controlled by using the flow control valves. Both the screw fittings and the Teflon tubing on the samplers are colorcoded for easy sample identification. Also fits Preppy SPE Vacuum. VISIPREP LARGE VOLUME SAMPLER for 2mL, 20mL, or 60mL SPE tubes (3 adapters) for 3mL or 6mL SPE tubes (4 adapters) REPLACEMENT PARTS /8" Teflon tubes, color-coded (pk. of 4) Nuts and ferrules, color-coded (pk. of 4) Stainless steel weights (pk. of 4) TUBE ADAPTERS, /4-28 THREADS For 3mL or 6mL tubes (pk. of 4) U For 2mL, 20mL, or 60mL tubes (pk. of 3) U Also, you must equip alternate manifold valves with long stem flow control knobs to accommodate 2mL, 20mL, or 60mL SPE tubes Teflon Tubing Tube Adapters Stainless Steel Weight 5760-U (order separately) P00032 Vacuum Guage / Bleed Valve Assembly Install in-line to allow control of vacuum Vacuum Guage / Bleed Valve Assembly 576-U 5720-U 2043-U Trap Kit for SPE Vacuum s Trap Kit for SPE Vacuum s When installed between a Visiprep SPE vacuum manifold and the vacuum source, a Supelco SPE Vacuum Pump Trap collects all liquids that are aspirated through the SPE tubes, preventing contamination of the vacuum pump. The easily assembled kit contains a polypropylene filtering flask, a one-hole rubber stopper, 4" (0cm) of polypropylene tubing and 5' (.5m) of red rubber vacuum hose. SPE Vacuum Pump Trap Kit 5720-U P000 P000 SPE Elution Rack This versatile stand-alone elution rack can be used with a variety of SPE tubes and receiving vessels, for simultaneous gravity feed extraction of up to 2 tubes. When using reversible tubes with luer endfittings, you can attach an empty syringe barrel to the tube to serve as a solvent reservoir. By assembling the plates in appropriate combinations, you can configure the rack to accept the following: ml, 3mL, or 6mL syringe barrel-type tubes Closed cartridge (reversible) tubes 5mL or 0mL volumetric flasks 2mL or 4mL vials Test tubes up to 5mm ID x 0cm SPE Elution Rack 2043-U P00002
6 Solid Phase Extraction (SPE) ENVI-Disk Accessories 69 ENVI-Disk Holder 5774 Funnel Teflon Base/ Adapter Flask (order separately) ENVI-Disk Holder 5773 Use the ENVI-Disk Holder with 47mm ENVI-DSK SPE disks. The unique design of the holder allows each disk to be installed and held firmly in place without wrinkling or tearing. A screw clamp provides uniform pressure on the disk and the sealing surfaces to prevent troublesome leaks spring-loaded clamps cannot offer the sealing integrity of the ENVI-Disk Holder. P0006 The unit consists of a -liter sample funnel, a threaded screw clamp, a Teflon disk support, and a Teflon filter base/adapter with a vacuum attachment fitting. The filter base fits onto any U standard -liter flask that has a 40/35 tapered ground glass neck. Use 25 x 250mm test tubes to collect disk eluates. The flask and collection tubes are not included with the holder, but can be purchased separately. ENVI-Disk Clamp To use the holder, place the base/adapter on the -liter flask and Eliminates leaks center an ENVI-Disk on the disk support in the base. Loosen the Attaches to any 34/45 tapered flask screw clamp to install the funnel, then tighten to secure the unit. ENVI-Disk Holder 5773 Flask, -liter, 40/35 fitting Z29060-EA Collection Tube, 25 x 250mm 5775 Order separately not included with holder. P0005 ENVI-Disk Holder The ENVI-Disk Holder holds one to six ENVI-Disk Holders with flasks, allowing you to simultaneously extract up to six -liter samples. Each of the six stations is controlled through an independent flow control valve. These valves are designed to vent the flask to the atmosphere when moved from the open to the closed position. The flow rate is controlled by the needle valve on the manifold. The unit includes a sturdy polymer base with six stations, six flow control valves, a needle valve, a vacuum gauge, and vacuum tubing. A -liter glass bottle in the manifold acts as a trap, to protect the vacuum source in the event of an overflow from one of the sample flasks. ENVI-Disk Holder 5774 When used with a standard 47mm glass filtration apparatus, the Attach the base/adapter to a vacuum source, and the unit is ready ENVI-Disk Clamp creates a better seal, eliminating leaks with to use. SPE extraction disks or when filtering HPLC mobile phase solvents. Use only with a filtration glassware funnel base that has a removable filtration stage, such as Supelco Mobile Phase Filtration Apparatus (Cat. No. 5806) or 2 (Cat. No U), or with a funnel base (Cat. No or 58068). It cannot be used with a permanent fritted glass filtration stage or stainless steel holder screen. ENVI-Disk Clamp, 47mm assembly U Replacement Teflon stage 5726 P0000
ORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
CataLoG No. weight o.d. i.d. GLaSSwaRe
Lead weights with Vikem Vinyl Coating Protect and Stabilize Expensive Glassware Stabilizes vessels in water baths and on benchtops Added insurance against tipping and possible chemical spills Closed ring
SciTech, sro Praha Ceník Jour Research tisk 3.1.2000
Ceny bez DPH, balného a poštovného. Jour Research pricelist 08/99 Part Number Description cena CZK 0001-0737 Wash-Pro Upgrade Kit 7098,00 0001-5530 Gas Flow Meter 22932,00 0001-5531 Silicon Connection
Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
How To Replace A Reverse Osmosis Water Tank
ALL MODELS REVERSE OSMOSIS WITH NONAIRGAP FAUCET 1. Read all instructions carefully before starting installation. 2. Find the cold water line beneath your sink. The cold water is typically on the right.
REPAIR AND MAINTENANCE MANUAL
REPAIR AND MAINTENANCE MANUAL Professional Pest Control Application Equipment Prime Line Sprayers B&G Equipment Company 135 Region South Drive, Jackson, GA 30233 800.544.8811 Phone 678.688.5601 Fax 678.688.5633
National- Spencer Inc.
9-27-2010 National- Spencer Inc. 19.2V HEAVY DUTY GREASE GUN PRODUCT SPECIFICATION Charger Input Power 110 VAC Battery Output Power 19.2V Battery Capacity 1500 MAH Battery Pack Charge Time 1 Hour Maximum
Installation Instructions
Installation Instructions S50-310 (Semi-Circular) S50-311 (Circular) Accu-Zone Infrared Control Conversion Kit for Terrazzo & Stainless Steel Classic Washfountains (Non-sectional) Table of Contents Pre-Installation
Mitos P-Pump. product datasheet
product datasheet page Product description 2 Main benefits 3 Why choose the Mitos P-Pump? 3 Closed-loop flow control 4 Product specifications 5 Accessories - overview 6 Mitos P-Pump Basic 7 Mitos P-Pump
MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK
1 565AKHU HYDRAULIC 1.22 O-RING - 2 REQUIRED UNIT 1.23 O-RING COMPLETE 1.24 TEFLON O-RING 2 REQUIRED 1.3 EXTENSION SCREW 1.3A SPRING PIN 1.4 SPRING SUPPORT 1.5 SCREW BUSHING 1.6 Y SHAPE SEAL RING 1.7 HEAD
INSTRUCTION. Industrial Sewing Machines. No. 010012. First published : June 1997 Second edition : March 2001
INSTRUCTION Industrial Sewing Machines First published : June 1997 Second edition : March 2001 No. 010012 INTRODUCTION Thank you for your purchasing Kansai Special's DLR Series. Read and study this instruction
Flow Solution Parts & Accessories
Flow Solution Parts & Accessories Assemblies Part # Instrument U/M Price Debubbler Debubbler, Acrylic A000172 All ea $140.00 Distillation Coil Heater Spool A515017 FS III/IV ea $495.00 Digestion Coil UV
ArtisanLink Staining System is an automated special stains slide
Technical Tips Tips on using the ArtisanLink Special Staining System Jamie Nowacek, BS, HT(ASCP) CM, QIHC, PMP Dako North America, Inc. Carpinteria, CA, USA ArtisanLink Staining System is an automated
FREE SAMPLE PACK Just ask.
FREE SAMPLE PACK Just ask. 2015 CHEMGLASS CERTIFIED 9MM THREADED 12 X 32MM VIALS Universally compatible with almost all autosamplers, the vials have an opening that is 40% larger than standard 8mm thread.
Installation Instructions 6028.801
DAZZLE Installation Instructions 08.80 Spread Lavatory Faucet with Speed Connect Drain* Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American
UNITOR VACUUM cleaners
UNITOR VACUUM cleaners Unitor VCD15 a compact, heavy-duty dry vacuum cleaner for accommodation areas The smallest unit in the Unitor range, the VCD15 is purpose-made for use on cruise and passenger vessels.
AIRFREE TECHNIQUE AND SENSITIVE REAGENTS S ECTI O N 1: GLASS W ARE A ND E Q UIP M ENT. A. Using a manifold
AIRFREE TECHNIQUE AND SENSITIVE REAGENTS S ECTI O N 1: GLASS W ARE A ND E Q UIP M ENT Some organic compounds are air sensitive. They can react with the water vapor or oxygen in the air. In order to perform
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 [email protected] www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS
Fixtures - Parts - Accessories to shampoo bowls
Page 1??? - For what brand of bowl do you need parts??? Find out by looking on the bottom of the bowl, between the front and strainer, where molded in the bottom is the brand and model number. For example,
NITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
Installation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
FRACTION COLLECTOR. Microcomputer Controlled CHF122SC
FRACTION COLLECTOR Microcomputer Controlled CHF122SC From open column to HPLC liquid chromatography and general liquid samplings, the Super Fraction Collector, model CHF122SC has a wide range of uses.
INSTRUCTIONS. FLHR/C/S (Road King) FRONT END LOWERING KIT 1WARNING -J03242 REV. 10-19-04. General. Removal (Left and Right Forks) Kit Number 54614-05
INSTRUCTIONS -J04 REV. 0-9-04 General FLHR/C/S (Road King) FRONT END LOWERING KIT This kit is designed for installation on 00 and later FLHR/C/S Model Motorcycles. Road King models use the conventional
15CI and 25CI Reversing Motor Pumpset Owner's Manual
ComNav Marine Autopilots #15-13511 Crestwood Place Richmond, BC Canada V6V 2G1 Telephone: 604-207-1600 Fax: 604-207-8008 In Canda or the U.S.A: Toll Free Phone: 1-800-428-0212 Toll Free Fax 1-800-470-9611
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
Experiment 12- Classification of Matter Experiment
Experiment 12- Classification of Matter Experiment Matter can be classified into two groups: mixtures and pure substances. Mixtures are the most common form of matter and consist of mixtures of pure substances.
COMMON LABORATORY APPARATUS
COMMON LABORATORY APPARATUS Beakers are useful as a reaction container or to hold liquid or solid samples. They are also used to catch liquids from titrations and filtrates from filtering operations. Bunsen
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
globe reactions made easy Process perfection
globe reactions made easy Process perfection Benefits More reactions in less time: The Globe oil drain unit and quick clamp allow single hand vessel changes in seconds Space saving: 50ml, 100ml, 250ml,
Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.
Here are some pictures to show what s required when replacing the A/C compressor, expansion valve and receiver/drier on a 2001 Volvo V70. Even if you don t replace these A/C parts these pictures can help
Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description
Technical Information Empore 96-Well Solid Phase Extraction Plates Instructions for Use Product Description Empore 96-Well Solid Phase Extraction Plates are designed for high throughput solid phase extraction
ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...
FUEL FILTER............................ FUEL HEATER.......................... INJECTOR.............................. SUPPLY PUMP.......................... COMMON RAIL.......................... FUEL PRESSURE
Purification of reaction mixtures using flash chromatography.
Purification of reaction mixtures using flash chromatography. This technical note details the use of ISOLUTE Flash chromatography columns for the purification of reaction mixtures. What is flash chromatography?
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
AIR LINE VALVES AND GAUGES
AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 2 HYDRAULIC AND PNEUMATIC CYLINDERS The material needed for outcome 2 is very extensive
Multiple flasks. Easy to adapt. Stuart range of heating blocks
Heating Blocks The Stuart range of heating blocks have been developed in conjunction with DrySyn to provide the best possible solution for heating round bottom flasks. Combined with the Stuart range of
CHEMICAL CLEANING UNIT Product number: 737189
CHEMICAL CLEANING UNIT Product number: 737189-1 - v.05/16 Content Page Intro 3 Specifications 4 Installation 5 Safety precautions 7 Maintenance 8 Spares and Accessories 8 Unitor Chemicals 9 Notes 10-2
ab204067-vacuum manifold for 96 well filter plates This product is for research use only and is not intended for diagnostic use.
ab204067-vacuum manifold for 96 well filter plates This product is for research use only and is not intended for diagnostic use. Version 2 Last Updated 06 November 2015 Table of Contents INTRODUCTION 1.
Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)
47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing
www.servicechamp.com
1-800-221-0216 Fax: 1-800-472-2281 www.servicechamp.com Service Champ Part 52081 Service Interval every 30,000 miles / Chevrolet 1992-2002 6.5 liter Description and Operation The fuel filter element separates
Thermo Scientific Nalgene Analytical Filtration Products
Thermo Scientific Nalgene Analytical Filtration Products For Reliable and Repeatable Monitoring and Testing of: water food and beverage raw materials finished product Thermo Scientific Nalgene Disposable
ReadyKart Mobile Processing Station Instructions for Use
GE Healthcare Instructions 28-9606-47 AB ReadyKart Mobile Processing Station Instructions for Use Contents ReadyToProcess 1 Introduction... 1 2 General Description... 2 3 Description of Components... 4
Many Products...One Source
PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K
TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V
TITAN pt. no.: 02 0000 0143 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended
WHATMAN ÜRÜN LİSTESİ 1 / 53 KATALOG NO AMBALAJ ŞEKLİ. Labsciences
Labsciences Sterivent 36, 0.2μm Inlet - 3/8 to 1/2 inch Stepped Hosebarb Outlet- 3/8 to 1/2 inch Stepped Hosebarb 1/pk 1/pk 2103 Sterivent 150, 0.2μm Inlet -3/8-1/2" Stepped Hosebarb Outlet- 3/8-1/2" Stepped
Probably the best Speed Vacuum Concentrators in the world
Probably the best Speed Vacuum Concentrators in the world Speed Vacuum Concentration Speed Vacuum Concentration from ScanVac allows easy and reproducible concentration of biological samples. Sample activity
Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
ISOLATION OF CAFFEINE FROM TEA
ISLATIN F CAFFEINE FRM TEA Introduction In this experiment, caffeine is isolated from tealeaves. The chief problem with the isolation is that caffeine does not exist alone in the tealeaves, but other natural
Automation of Solid Phase Extraction and Column Chromatographic Cleanup
Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for
Samco Scientific Liquid Handling Solutions
1 Samco Scientific Liquid Handling Solutions Our products have been delivering quality, safety and craftsmanship to the clinical, research and industrial markets since 1971. Our comprehensive range of
Solids, Volatile Dissolved and Fixed Dissolved
, 8277 Solids, Volatile Dissolved and Fixed Dissolved Gravimetric Method 1 Scope and Application: For wastewater. 1 Adapted from Standard Methods for the Examination of Water and Wastewater DOC316.53.001206
Solstice/Sky Water Pump Replacement
Solstice/Sky Water Pump Replacement The water pump on the Solstice/Sky is starting to need replacement on some vehicles. This guide will help in replacing the water pump while the engine is still in the
not appearance. ADHESIVE SYSTEMS CORIAN As an integral part of its sheet and shape products, DuPont has developed a special adhesive.
CORIAN JOINT ADHESIVE SYSTEM 8.1 CORIAN JOINT ADHESIVE SYSTEM As an integral part of its sheet and shape products, DuPont has developed a special adhesive. The DuPont Corian covers seam performance, not
SHOT BLAST CABINET MODEL NO: CSB20B
SHOT BLAST CABINET MODEL NO: CSB20B PART NO: 7640110 USER INSTRUCTIONS GC0216 INTRODUCTION Thank you for purchasing this CLARKE Shot Blast Cabinet which is designed for professional workshop use. Before
Flash Chromatography, Synthesis and Work-up Products
Kinesis Ltd kinesis.co.uk Kinesis Inc kinesis-usa.com Kinesis GmbH (formerly Abimed) kinesisgmbh.de Kinesis Australia Pty Ltd kinesis-australia.com.au Flash Chromatography, Synthesis and Work-up Products
Isolation of Caffeine from Tea
Isolation of Caffeine from Tea Introduction A number of interesting, biologically active compounds have been isolated from plants. Isolating some of these natural products, as they are called, can require
Rheodyne Manual Sample Injector Valves
Rheodyne Manual Sample Injector Valves Rotor Seal Shaft End Rotor Seal Groove Stator Face Stator Stator Face Seal Rotor Seal Grooves Position A Rotor Seal Grooves Position B Position C Flow paths showing
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9
Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
105 Adopted: 27.07.95
105 Adopted: 27.07.95 OECD GUIDELINE FOR THE TESTING OF CHEMICALS Adopted by the Council on 27 th July 1995 Water Solubility INTRODUCTION 1. This guideline is a revised version of the original Guideline
Mixtures and Pure Substances
Unit 2 Mixtures and Pure Substances Matter can be classified into two groups: mixtures and pure substances. Mixtures are the most common form of matter and consist of mixtures of pure substances. They
Jay R. Smith Mfg. Co.
Jay R. Smith Mfg. Co. Automatic Backwater Valve SMITH CUSTOMER DRIVEN FLOOD-GATE FEATURES Index Page Flood-Gate Features and Applications 2 How Flood-Gate Works 3 Flood-Gate Operation & Approvals 4 Valve
NIH Clinical Center Patient Education Materials Giving a subcutaneous injection
NIH Clinical Center Patient Education Materials What is a subcutaenous injection? A subcutaneous injection is given in the fatty layer of tissue just under the skin. A subcutaneous injection into the fatty
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
FOR ANY QUESTIONS, PLEASE CALL US @ 727.347.9915 M-F 8:00a.m.-8:00p.m. EST. REAR BRAKES 1 AEROSPACE COMPONENTS 727.347.9915
REAR BRAKES 1 AEROSPACE COMPONENTS 727.347.9915 REAR BRAKES Before getting started, remove all stock braking components. Pre-assembly of parts: Clean the bolts and the threads in the hat with acetone.
Watts Pure Water Systems
Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC
RECOVERY SUPEREVAC 29 RECOVERY 1/4" 4-IN-1 BALL VALVE TOOL For vacuum, charge, cores and recovery 18997 18975 18971 18978 18979 Remove and replace Schrader cores without losing charge. Extra 1/4" side
Fuel Injection Pump, Rotary (005-014)
Fuel Injection Pump, Rotary View Related Topic Page 1 of 30 Fuel Injection Pump, Rotary (005-014) Table of Contents Summary General Information Preparatory Steps Remove Front Gear Train Rear Gear Train
Procenter Delivery System* Troubleshooting Charts
1 2 3 4 Procenter Delivery System* Troubleshooting Charts * includes International (Whip) Units Component Page Procenter / Int l. (Whip) Delivery Units*... 2 Assistant s Units...6 Midmark Cuspidor...7
INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS
INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS SETTING UP THE PRESS FOR OPERATION For shipping convenience, the gauge, pump handle, hoist crank, screw nose and base angles
Aseptic Technique. A GMP/GTP Training Module
Aseptic Technique A GMP/GTP Training Module Aseptic Technique The GMP Facility manufactures products for clinical use These products must meet a number of requirements, one of which is that they are sterile
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
2006 HEADSHOK Service Video #1
LEFTY SPEED DLR DAMPING CARTRIDGE This document explains how to properly remove, disassemble, inspect, reassemble and reinstall the Lefty Speed DLR2 damping cartridge. It is a document to be used in conjunction
Recharge Procedure for Telemark TVP-2000 and TVP-3500
Recharge Procedure for Telemark TVP-2000 and TVP-3500 Required items: 1.) Refrigeration service manifold. 2.) Charge recovery system. 3.) Dry nitrogen gas. If a high pressure cylinder is used, a pressure
INSTRUCTIONS 56-1190-98. Edition AC
Sephacryl S-100 High Resolution Sephacryl S-200 High Resolution Sephacryl S-300 High Resolution Sephacryl S-400 High Resolution Sephacryl S-500 High Resolution INSTRUCTIONS Sephacryl High Resolution chromatography
LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions
LORTONE LU6X-130 Item # 061-092 LU6X Basic Item # 061-090 LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions Introduction The LU6X is one the most versatile pieces of equipment
Gas Chromatograph GC Consumables. p/n: 220-94898-02
Gas Chromatograph GC Consumables p/n: 220-94898-02 Diag. # 1) Septum Nut 2) Needle Guide 3) Septum 4) Injection Port A Assy 5) O-ring for Glass Insert 6) Glass Insert 7) Gold Gasket 8) Capillary Adaptor
www.sampling.com World Class Equipment worldwide Edition J
www.sampling.com World Class Equipment worldwide Edition J Welcome Welcome to the latest edition of our Range Brochure Firstly, we would like to thank you our customers for helping us create the new range
MOISTURE (Karl Fischer, Buffered)
MOIST.03-1 MOISTURE (Karl Fischer, Buffered) PRINCIPLE SCOPE The sample is dissolved in a mixture of methanol and formamide (50:50 v/v) and then titrated with standardized Karl Fischer reagent. The titration
Helping to protect you from exposure to hazardous drugs
Helping to protect you from exposure to hazardous drugs Closed system solution: Texium closed male luer and SmartSite needle-free valve products What you can t see can hurt you The risks are well documented
The Strange Effects of a Vacuum
The Strange Effects of a Vacuum Equipment List Mechanical vacuum pump (1 to 16 cfm) with oil mist filter on outlet. Vacuum connection: Tygon tubing (~5/8 inch O.D.), in-line vacuum shut off valve, vent
Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
CutMaster 102. 6.04 Major External Replacement Parts
CutMaster 0 6.04 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-086 Tube, roll handle 9-0 4 Front Panel 9-087 Rear Panel 9-00 4 Art #
CHROME FRONT BRAKE MASTER CYLINDER KIT
-J075 REV. 009-0-0 CHROME FRONT BRAKE MASTER CYLINDER KIT GENERAL Kit Number 5-99D, 5-99D Models These Chrome Master Cylinder Kits are designed to replace the original equipment front brake master cylinder
Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation
Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.
CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST
CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST 1 Permeability is a measure of the ease in which water can flow through a soil volume. It is one of the most important geotechnical parameters. However,
Before repairing your toilet, you must determine
Before repairing your toilet, you must determine which type of toilet you have. Pressurized Toilets If you have a pressurized toilet, it is recommended that you call a licensed plumbing contractor to repair
Professional Precharged Hunting Rifle
TRIGGER ADJUSTMENT. The trigger is set at the factory, but some aspects can be adjusted to suit individual preferences. 1. This screw adjusts the weight of second stage trigger pull, to increase the weight
Shower and Floor Gullies Channel Drain and Tile Drain SECTION
Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions
Sample Collection Procedures for Insulating Fluid Samples
Sample Collection Procedures for Insulating Fluid Samples GENERAL Sampling electrical insulating oil for laboratory analysis requires care to ensure that the sample is representative of the product being
11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50
11 COOLING SYSTEM SERVICE INFORMATION------------------------------------------------ 11-1 TROUBLESHOOTING----------------------------------------------------- 11-1 RADIATOR ------------------------------------------------------------------
Joplin Rebuild Instructions
Joplin Rebuild Instructions This is a step by step list of instruction on how to rebuild the Crankbrothers Joplin post. It may not always be required to completely tear-down the post to do the work needed
Extraction: Separation of Acidic Substances
Extraction: Separation of Acidic Substances Chemists frequently find it necessary to separate a mixture of compounds by moving a component from one solution or mixture to another. The process most often
#12 Professional Meat Grinders
#12 Professional Meat Grinders MG-203100 (52021040) Manual Instruction Thank you, and congratulations on purchasing the Non-corrosive electric meat grinder. Your grinder comes complete with everything
YELLOW JACKET Hose Adapters, Valves, and Parts right to the last detail
YELLOW JACKET Hose Adapters, Valves, and Parts right to the last detail NEW Valve core tool page 35 EXPANDED LINE Quick couplers page 36 33 1/4" 4-IN-1 BALL VALVE TOOL for vacuum, charge, cores and recovery
Coolflo Safe Touch Shower Mixing Valve ST20015CP
Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept