12 D-Flex and D-Flex Microporous (DC-4. GHz.) High Temperature / High Frequency Semi-igid eplacement for.47,.86 and.141 sizes. Uses Standard Semi-igid Connectors. Connectors Available for D-Flex Series... DynaFlex Series 1 (DC-. GHz.) Suitable for all applications requiring a combination of excellent electrical performance and robust physical characteristics. Connectors Available for DynaFlex Series 1... DynaFlex Series 2 (DC-4. GHz.) Suitable for all applications where low attenuation or phase stability are the primary design concerns. Connectors Available for DynaFlex Series 2... DynaFlex Series 3 (DC-4. GHz.) Suitable for all applications where weight savings is the primary design concern with Static installations in Land, Sea, Mobile, and Airborne Platforms. Connectors Available for DynaFlex Series 3... DynaFlex Series 4 (DC-65. GHz.) Suitable for all dynamic flexure applications when excellent flexibility and small bending forces are required. Connectors Available for DynaFlex Series 4... Cable Assemblies Pages Cable Assembly Code Cable Assembly Tooling Engineering Notes Competitors Cross eference The most commonly used Cables in the F Industry crossed to Dynawave Cable part numbers. 2 Table of Contents

13 D-Flex Cable Series D-Flex Series D-Flex Microporous Series DC - 4 GHz. Application & Product Features The D-Flex and D-Flex Microporous Series replace semi-rigid cable with a flexible equivalent while eliminating the need for three dimensional drawings, thereby simplifying the manufacturing processes and reducing cost. Both cable types provide easy solder termination to all (.47,.86, and TM.141) semi-rigid connectors. The D-Flex Series is equivalent to the popular *TFlex cable types with solid PTFE cores and the new D-Flex Microporous Series offers extended operational frequencies and temperature ranges by utilizing DynaCore PTFE Dielectric Technology. Suitable for all semi-rigid applications where cost savings is a concern. Component interconnections inside drawers, cabinets and enclosures. Military Defense systems, Medical systems, Telecommunication systems, Commercial antennas and Sub systems. Medical MI applications (D-Flex Microporous) when mating to non-magnetic connectors. Frequency range to 4 GHz. Shielding effectiveness >1 db Flexure life >1, cycles at 5x minimum bend radius. w w w. d y n a w a v e c a b l e. c o m

14 s with Cable Characteristics D-Flex D-Flex Microporous D-Flex s DX86 DX141 DXM47 DXM86 DXM141 Impedance (ohms) Velocity of Propagation (%) Min. Shield Effectiveness (db) Phase vs. Flexure Phase vs. Temperature Min. breakdown Voltage (KV) Capacitance (pf / ft.) Inductance (nh / ft.) Max. Operating Frequency (GHz.) Max. Structural VSW Max. Temperature (Deg. C ) Operating Temperature (Deg. C ) Jacket (in.) Second Shield O.D. (in.) First Shield O.D. (in.) Dielectric O.D. (in.) Solid Center Conductor O.D. (in.) Inside Min. Bend adius (in.) Flexure Life (5x Min. Bend adius) Weight (lbs. / ft.) : 1-45 / / >1, >1, See Graph (Pg. 5) See Graph (Pg. 5) -65 / : * : See Graph (Pg. 5) See Graph (Pg. 5) : 1-65 / +2 Cable Construction & Specifi cations : 1 The D-Flex and D-Flex Microporous cable series come with high temperature ETFE jackets and fi ts all standard sized semi-rigid connectors for.47,.86 and.141 diameter cables. Non-magnetic constructions are available for all but the DXM47. D-Flex D-Flex Microporous Jacket : ETFE First Shield, Silver Plated Copper per ASTM B298 Center Conductor Silver Plated Copper Clad Steel Jacket : ETFE First Shield, Silver Plated Copper per ASTM B298 *DXM47- WOVEN BAID DXM141 & DXM86-HELICAL FOIL Center Conductor Silver Plated Copper per ASTM B298 (See Note) Second Shield Silver Plated Copper per ASTM B298 PTFE Dielectric Type F per ASTM D4894 and D4895 Second Shield Silver Plated Copper per ASTM B298 NOTE: DXM47 has a Silver Plated, Copper Clad Steel Center Conductor Dynacore Expanded PTFE Dielectric Type F per ASTM D4894 and D Specifications are subject to change without notice

15 Power, Attenuation & Phase Characteristics Power De-rating for Temp. & Altitude Power handling is specified for conditions at sea level and +25 degrees C. Use the de-rating chart to estimate average or peak power levels at other altitude or temperature conditions. For power ratings on cable assemblies see page 35. % of ated Power Temp. Altitude Altitude (1's ft) Temp. (Deg. C) GHz K1 K2 Attenuation (db/1 ft.) D-Flex D-Flex Microporous DX86 DX141 DXM47 DXM86 DXM Attenuation = (K1 * db/1 ft freq. (GHz.)) + (K2 * freq. (GHz.)) Attenuation vs Frequency DX86 DX GHz. GHz db/1 ft Average Power ating (K Watts) D-Flex D-Flex Microporous DX86 DX141 DXM47 DXM86 DXM Attenuation vs Frequency DXM47 DXM86 DXM GHz. K Watts Power vs Frequency DX86 DX GHz. K Watts Power vs Frequency DXM47 DXM86 DXM GHz. Phase vs Temperature Phase vs Flexure D-Flex (microporous) D-Flex Temp. (Deg. C) Specifications are subject to change without notice Phase Change (+/- Deg.) (See Eng. Note 1 on page 36) Phase Change (+/- Deg.) Phase change with 36 degree loop at the minimum bend radius 47 Size 86 & 141 Sizes 1 GHz

16 Connector Specifi cations Dynawave connectors offer the best combination of price and performance. All connectors meet or exceed MIL-PF-3912 or MIL-STD-348 interface requirements and employ corrosion resistant stainless steel bodies, PTFE insulators, silicone gasket seals and gold plated BeCu contacts. These connectors utilize precision interfaces designed for greater than mating cycles without performance degradation. Connector Selection * Cable Type DX86 DX141 DXM47 DXM86 DXM141 SMP, Jack, Straight SMPM, Jack, Straight SMA, Plug, Straight SMA, Plug, /A SMA, Jack, Bulkhead 2.4mm, Plug, Straight 2.4mm, Plug, /A 2.4mm, Jack, Bulkhead 2.92mm, Plug, Straight 2.92mm, Plug, /A 2.92mm, Jack, Bulkhead TNC, Plug, Straight TNC, Plug, /A TNC, Jack, Bulkhead N, Plug, Straight N, Plug, /A N, Jack, Bulkhead DX DX DX DX DX DX DX DX DX DX DX DX DX DX DX DX DX DX DX DX DX DX DX DX DX DX DX DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM DM * We also offer the Design and Manufacture of Special Connectors to meet your requirements 6

17 DYNAWAVE Cable Assembly Specifi cations See page 34 to determine a Code for your requirement, or contact our factory for custom cable assemblies tailored to your specifications. Our 1% tested and factory certifi ed assemblies are manufactured with semi-automated assembly methods and statistical process controls. In addition, all soldering operations are IPC/WHMA-A-62 or IPC-J-STD-1 certifi ed. This produces consistent, predictable products that protect signal integrity and ensures excellent transmission quality every time. Several variations of standard connector interfaces are available for this cable series. In addition, a rugged strain relief at the cable/connector junction comes standard to improve the dependability of these assemblies. Available jacket types for this cable are listed below with specifi c mechanical performance attributes. listed on page 34. High Temperature (H): Blue ETFE jacket with the highest available temperture rating. Basic Cable Assembly Configuration : LENGTH LENGTH LENGTH DYNAWAVE DYNAWAVE DYNAWAVE DYNAWAVE Standard Electrical Testing includes VSW and Insertion Loss. Cable Assembly Electrical Specifications Cable Assembly VSW Matrix Standard Testing (1%) Max. Assembly VSW Max. Assembly Insertion Loss See VSW Matrix Loss Calculator in Appendix (refer to page 8) DC - 4 GHz. Connector End 1 Straight (Plug or Jack) ight Angle (Plug) Straight (Plug or Jack) 1.35 : 18 GHz. 1.4 : 26 GHz : 4 GHz. 1.4 : 18 GHz : 26 GHz. 1. : 4 GHz. Connector End 2 ight Angle (Plug) 1.4 : 18 GHz : 26 GHz. 1. : 4 GHz : 18 GHz. 1. : 26 GHz. 1.6 : 4 GHz. Specifications are subject to change without notice 7

18 Loss Calculations Freq. (GHz.) K1 K2 D-Flex (db/in.) D-Flex Microporous (db/in.) Connector Loss (db) Mismatch Loss DX86 DX141 DXM47 DXM86 DXM141 Straight t. Angle VSW Loss (db) Attenuation = (K1 * freq. (GHz.)) + (K2 * freq. (GHz.)) Max. Assembly Loss = (Cable Loss) +(Connector #1 Loss + Connector #2 Loss) + (Mismatch Loss) Example : 37 inch long Cable Assembly, DX86 cable, with one straight and one right angle connector. Freq. = 12. GHz., VSW = 1.2 : 1. Insertion Loss = (37 x.694) + ( ) + (.4) = 2.777dB. Cross eference by Dynawave Cross eference by Competitors Dynawave Cable 8 DX86 DX86 DX86 DX86 DX141 DX141 DX141 DX141 DXM47 DXM47 DXM47 DXM86 DXM86 DXM86 DXM86 DXM141 Competitors Harbour SS45 Semfl ex SM45 Storm Products Storm Flex 86 Times Microwave Tfl ex 45 Harbour SS42 Semfl ex SM42 Storm Products Storm Flex 141 Times Microwave Tfl ex 42 Micro Coax UGN7D Semfl ex SW6 Storm Products Storm Flex 47 Insulated Wire 1151 Insulated Wire 1251 Micro Coax UFF92D Semfl ex SW86 Semfl ex SW1 Competitors Harbour SS45 Harbour SS42 Insulated Wire 1151 Insulated Wire 1251 Micro Coax UGN7D Micro Coax UFF92D Semfl ex SM45 Semfl ex SM42 Semfl ex SW6 Semfl ex SW86 Semfl ex SW1 Storm Products Storm Flex 47 Storm Products Storm Flex 86 Storm Products Storm Flex 141 Times Microwave Tfl ex 45 Times Microwave Tfl ex 42 Dynawave Cable DX86 DX141 DXM86 DXM86 DXM47 DXM86 DX86 DX141 DXM47 DXM86 DXM141 DXM47 DX86 DX141 DX86 DX141 Specifications are subject to change without notice

19 DynaFlex Cable Series Series DF1 DC - GHz. Application & Product Features This is Dynawave s best all around F/Microwave interconnect cable series, balancing great electrical performance with resilient mechanical properties. The series DF1 also features the low density DynaCore PTFE dielectric with a robust tri-shield construction. The use of two woven braids with a wrapped foil provides resistance to damage from axial torque and rough handling. This also results in stable electrical performance and extended service in harsh physical environments. This series is suitable in Static applications on Land, Sea, Mobile and Airborne Platforms. Suitable for all applications requiring a combination of excellent electrical performance and robust physical characteristics. Static installations on Land, Sea, Mobile and Airborne Platforms. Indoor and outdoor installations with exposure to sand, dust, sunlight, moisture, shock and vibration. High volume Test & Measurement applications. Frequency ranges up to GHz. Maximum temperature range -65 C to +2 C (dependent on outer jacket option). Shielding effectiveness >9 db. Flexure life 1, cycles at 5x minimum bend radius. Applications requiring higher flexure life see Series 4. Electronic Counter Measures, Electronic Warfare Systems, Mobile Military Communications Systems & Satellite Communication. w w w. d y n a w a v e c a b l e. c o m

20 s with Cable Characteristics DynaFlex High Temperature Weatherized DF118 DF126 DF1 DF118W DF126W W DF1W Impedance (ohms) Velocity of Propagation (%) Min. Shield Effectiveness (db) Phase vs. Flexure Phase vs. Temperature Min. breakdown Voltage (KV) Capacitance (pf / ft.) Inductance (nh / ft.) Max. Operating Frequency (GHz.) Max. Structural VSW Max. Temperature (Deg. C ) Operating Temperature (Deg. C ) Jacket (in.) Third Shield O.D. (in.) Second Shield O.D. (in.) First Shield O.D. (in.) Dielectric O.D. (in.) Solid Center Conductor O.D. (in.) Inside Min. Bend adius (in.) Flexure Life (5x Min. Bend adius) Weight (lbs. / ft.) See Graph (Pg. 11) See Graph (Pg. 11) See Graph (Pg. 11) See Graph (Pg. 11) : : : : : : : 1-65 / / / / >1, >1, : Cable Construction & Specifi cations DynaFlex 1 Series cables offer an optional polyurethane jacket for excellent UV resistance in outdoor installations or for low smoke, halogen free jacket requirements. Solid center conductors contribute to better attenuation performance and are best suited for applications requiring less than 1, fl exures. (For Applications requiring Higher Flexure Life see Series 4). Jacket Options, High Temp. (H) : ETFE Weatherized (W) : Polyurethane First Shield, Silver Plated Copper per ASTM B298 Center Conductor Silver Plated Copper per ASTM B298 1 Third Shield, Silver Plated Copper per ASTM B298 Dynacore Expanded PTFE Dielectric Type F per ASTM D4894 and D4895 Second Shield High Temp. Aluminum Polyimide Foil Specifications are subject to change without notice

21 Power, Attenuation & Phase Characteristics Power handling is specified for conditions at sea level and +25 degrees C. Use the de-rating chart to estimate average or peak power levels at other altitude or temperature conditions. For power ratings on cable assemblies see page 35. Power De-rating for Temp. & Altitude GHz Average Power ating (K Watts) DF118 DF126 DF Power vs Frequency % of ated Power Temp. Altitude Altitude (1's ft) / Temp. (Deg. C) K Watts DF118 DF126 DF GHz. db / 1 ft Attenuation vs Frequency DF118 DF126 DF GHz. Phase vs Temperature GHz K1 K2 Attenuation (db/1 ft.) DF118 DF126 DF Attenuation = (K1 * freq. (GHz.)) + (K2 * freq. (GHz.)) Phase vs Flexure Deg. C Specifications are subject to change without notice Phase Change (ppm) (See Eng. Note 1 on page 36) Phase Change (+/- Deg.) Phase change with 36 degree loop at the min. bend radius GHz. 11

22 Connector Specifi cations Dynawave connectors offer the best combination of price and performance. All connectors meet or exceed MIL-PF-3912 or MIL-STD-348 interface requirements and employ corrosion resistant stainless steel bodies, PTFE insulators, silicone gasket seals and gold plated BeCu contacts. These connectors utilize precision interfaces designed for greater then mating cycles without performance degradation. Connector Selection * Cable Type DF118 DF126 DF1 SMP, Jack, Straight SMA, Plug, Straight SMA, Plug, /A SMA, Jack, Bulkhead 2.4mm, Plug, Straight 2.4mm, Plug, /A 2.4mm, Jack, Bulkhead 2.92mm, Plug, Straight 2.92mm, Plug, /A 2.92mm, Jack, Bulkhead TNC, Plug, Straight TNC, Plug, /A TNC, Jack, Bulkhead N, Plug, Straight N, Plug, /A N, Jack, Bulkhead SC, Plug, Straight SC, Plug, /A SC, Jack, Bulkhead H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H-624 Weatherized Connector Selection * 2-1H H H H H H H H H H-624 Cable Type DF118W DF126W W DF1W SMA, Plug, Straight SMA, Plug, /A SMA, Jack, Bulkhead 2.4mm, Plug, Straight 2.4mm, Plug, /A 2.4mm, Jack, Bulkhead 2.92mm, Plug, Straight 2.92mm, Plug, /A 2.92mm, Jack, Bulkhead TNC, Plug, Straight TNC, Plug, /A TNC, Jack, Bulkhead N, Plug, Straight N, Plug, /A N, Jack, Bulkhead SC, Plug, Straight SC, Plug, /A SC, Jack, Bulkhead W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W-624 * We also offer the Design and Manufacture of Special Connectors to meet your requirements 12

23 DYNAWAVE Cable Assembly Specifi cations See page 34 to determine a Code for your requirement, or contact our factory for custom cable assemblies tailored to your specifications. Our 1% tested and factory certifi ed assemblies are manufactured with semi-automated assembly methods and statistical process controls. In addition, all soldering operations are IPC/WHMA-A-62 or IPC-J-STD-1 certifi ed. This produces consistent, predictable products that protect signal integrity and ensures excellent transmission quality every time. Several variations of standard connector interfaces are available for this cable series. Weatherized (W) connector versions combine silicone seals and corrosion resistant stainless steel components to provide an impenetrable moisture barrier and long service life in outdoor installations. In addition, a rugged strain relief at the cable/connector junction comes standard to improve the dependability of these assemblies.. HIGH. WEATHEIZED Available jacket types for this cable are listed below with specifi c mechanical performance. UGGEDIZED. AMOED TEMPEATUE (H): Grey ETFE jacket with the highest available temperture rating. (Flame esistance and Low Smoke rating = UL94 V-) (W): Black polyurethane jacket with a lower temperture rating but improved fl exibility, high UV resistance and moisture sealed connectors. (Zero Halogen, Flame esistance and Low Smoke rating = UL94 V-). (): UltraFlex, stainless steel, interlocked casing with blue polyurethane jacket. This combines crush resistance with fl exibility and light weight. (A): Seamless, stainless steel, corrugated tube with stainless steel braid and black polyurethane jacket. This produces the highest crush resistance, torque resistance and tensile strength of all jacket options, but sacrifi ces fl exibility. Basic Cable Assembly Configuration : LENGTH LENGTH LENGTH DYNAWAVE DYNAWAVE DYNAWAVE DYNAWAVE Standard Electrical Testing includes VSW and Insertion Loss. Testing for other performance parameters such as phase and amplitude matching or special environmental conditions is available upon request. Standard Testing (1%) Optional Test (as required) Cable Assembly Electrical Specifications Specifications are subject to change without notice Max. Assembly VSW Max. Assembly Insertion Loss Phase Matching Phase Tracking See VSW Matrix Loss Calculator in Appendix (refer to page 14) < +/-.5 Deg. / GHz. < +/-.1 Deg. / GHz. / ft. Insertion Loss Matching + / - 3% DC - GHz. Connector End 1 Straight (Plug or Jack) ight Angle (Plug) Cable Assembly VSW Matrix Straight (Plug or Jack) 1.3 : 18 GHz : 26 GHz. 1.4 : GHz : 18 GHz. 1.4 : 26 GHz : GHz. Connector End 2 ight Angle (Plug) 1.35 : 18 GHz. 1.4 : 26 GHz : GHz. 1.4 : 18 GHz : 26 GHz. 1. : GHz. 13

24 Freq. (GHz.) K1 K2 Cable Loss (db / in.) Loss Calculations Connector Loss (db) Mismatch Loss DF118 DF126 DF1 Straight t. Angle VSW Loss (db) Attenuation = (K1 * freq. (GHz.)) + (K2 * freq. (GHz.)) Max. Assembly Loss = (Cable Loss) + (Connector #1 Loss + Connector #2 Loss) + (Mismatch Loss) Example : 37 inch long Cable Assembly, DF126 cable, with one straight and one right angle connector. Freq. = 12. GHz., VSW = 1.2 : 1. Insertion Loss = (37 x.268) + ( ) + (.4) = 1.26 db. Cross eference by Dynawave Cross eference by Competitors Dynawave Cable 14 DF118 DF118 DF118 DF126 DF126 DF126 DF126 DF1 DF1 DF1 DF1 DF1 DF1 Competitors Harbour LL393-2 Semflex HP35s Storm Products True Blue 29 Micro Coax UFA21A Semflex HP19s Storm Products True Blue 25 Tensolite 31 Harbour LL142 Harbour LL21 Insulated Wire 161 Micro Coax UFA147A Semflex HP16s Tensolite TLL4-113A Tensolite 4 Harbour LL12 Insulated Wire 141 Micro Coax UFA125A Semflex HP12s Storm Products True Blue 125 Tensolite TLL4-1111A Competitors Harbour LL393-2 Harbour LL142 Harbour LL21 Harbour LL12 Insulated Wire 141 Insulated Wire 161 Micro Coax UFA21A Micro Coax UFA147A Micro Coax UFA125A Semflex HP35s Semflex HP19s Semflex HP16s Semflex HP12s Storm Products True Blue 29 Storm Products True Blue 25 Storm Products True Blue 125 Tensolite 31 Tensolite 4 Tensolite TLL4-113A Tensolite TLL4-1111A Dynawave Cable DF118 DF1 DF1 DF126 DF1 DF118 DF126 DF1 DF118 DF126 DF1 DF126 DF1 Specifications are subject to change without notice

25 DynaFlex Cable Series Series DF2 DC - 4 GHz. Application & Product Features This is Dynawave s Electrically Optimized F/Microwave interconnect cable series. The Series DF2 also features a wrapped foil inner shield that minimizes attenuation and greatly improves phase stability with flexure. In addition, the ultra low density DynaCore PTFE dielectric improves phase over temperature. This type of construction offers excellent electrical performance where ultra low attenuation or phase stability is required. If the application involves radial torque forces that are greater than 15 lb-in additional armor protection would be recommended. Suitable for all applications where low attenuation or phase stability are the primary design concerns. Static installations on Land, Sea, Mobile and Airborne Platforms. Indoor and outdoor installations with exposure to sand, dust, sunlight and moisture. Excellent for applications in adar Systems, Phase Array Antennas and Test & Measurement Systems. Frequency ranges up to 4 GHz. Maximum temperature range -65 C to +2 C (dependent on outer jacket option). Shielding effectiveness >1 db. Flexure life >1, cycles at 5x minimum bend radius. w w w. d y n a w a v e c a b l e. c o m

26 s with Cable Characteristics DynaFlex High Temperature Weatherized W W W Impedance (ohms) Velocity of Propagation (%) Min. Shield Effectiveness (db) Phase vs. Flexure Phase vs. Temperature Min. breakdown Voltage (KV) Capacitance (pf / ft.) Inductance (nh / ft.) Max. Operating Frequency (GHz.) See Graph (Pg. 17) See Graph (Pg. 17) See Graph (Pg. 17) See Graph (Pg. 17) Max. Structural VSW Max. Temperature (Deg. C ) Operating Temperature (Deg. C ) 1.25 : : 1-65 / / : : : 1-65 / / : 1 Jacket (in.) Second Shield O.D. (in.) First Shield O.D. (in.) Dielectric O.D. (in.) Solid Center Conductor O.D. (in.) Inside Min. Bend adius (in.) Flexure Life (5x Min. Bend adius) >1, >1, Weight (lbs. / ft.) Cable Construction & Specifi cations DynaFlex Series 2 cables offer an optional polyurethane jacket for excellent UV resistance in outdoor installations or for low smoke, halogen free jacket requirements. Solid center conductors contribute to better attenuation performance and are best suited for applications requiring up to 1, fl exures. It should be noted that DynaFlex Series is equivalent to Semflex LA29 or Times Microwave HF-29 cable types and fi ts all connectors designed for those two products. Jacket Options, High Temp. (H) : ETFE Weatherized (W) : Polyurethane First Shield, Silver Plated Copper per ASTM B298 Center Conductor Silver Plated Copper per ASTM B298 Second Shield, Silver Plated Copper per ASTM B298 DynaCore Expanded PTFE Dielectric Type F per ASTM D4894 and D Specifications are subject to change without notice

27 Power, Attenuation & Phase Characteristics Power handling is specified for conditions at sea level and +25 degrees C. Use the de-rating chart to estimate average or peak power levels at other altitude or temperature conditions. For power ratings on cable assemblies see page 35. Power De-rating for Temp. & Altitude GHz Average Power ating (K Watts) Power vs Frequency % of ated Power Temp. Altitude Altitude (1's ft.) / Temp. (Deg. C) K Watts GHz. Attenuation vs Frequency Attenuation (db/1 ft.) GHz. db/1 ft GHz K1 K Attenuation = (K1 * freq. (GHz.)) + (K2 * freq. (GHz.)) Phase vs Temperature Phase vs Flexure Deg. C Specifications are subject to change without notice Phase Change (ppm) (See Eng. Note 1 on page 36) Phase Change (+/- Deg.) Phase change with 36 degree loop at the min. bend radius GHz. 17

28 18 Connector Specifi cations Dynawave connectors offer the best combination of price and performance. All connectors meet or exceed MIL-PF-3912 or MIL-STD-348 interface requirements and employ corrosion resistant stainless steel bodies, PTFE insulators, silicone gasket seals and gold plated BeCu contacts. These connectors utilize precision interfaces designed for greater than mating cycles without performance degradation. Connector Selection * Cable Type SMA, Plug, Straight SMA, Plug, /A SMA, Jack, Bulkhead 2.4mm, Plug, Straight 2.4mm, Plug, /A 2.4mm, Jack, Bulkhead 2.92mm, Plug, Straight 2.92mm, Plug, /A 2.92mm, Jack, Bulkhead TNC, Plug, Straight TNC, Plug, /A TNC, Jack, Bulkhead N, Plug, Straight N, Plug, /A N, Jack, Bulkhead SC, Plug, Straight SC, Plug, /A SC, Jack, Bulkhead H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H-624 Weatherized Connector Selection * Cable Type W W W SMA, Plug, Straight W W-624 SMA, Plug, /A W W-624 SMA, Jack, Bulkhead W W mm, Plug, Straight 12-24W mm, Plug, /A W mm, Jack, Bulkhead W mm, Plug, Straight W W mm, Plug, /A W W mm, Jack, Bulkhead W W-624 TNC, Plug, Straight W W-624 TNC, Plug, /A W W-624 TNC, Jack, Bulkhead W W-624 N, Plug, Straight W W-624 N, Plug, /A W W-624 N, Jack, Bulkhead W W-624 SC, Plug, Straight W-624 SC, Plug, /A W-624 SC, Jack, Bulkhead W-624 * We also offer the Design and Manufacture of Special Connectors to meet your requirements

29 DYNAWAVE Cable Assembly Specifi cations See page 34 to determine a Code for your requirement, or contact our factory for custom cable assemblies tailored to your specifications. Our 1% tested and factory certifi ed assemblies are manufactured with semi-automated assembly methods and statistical process controls. In addition, all soldering operations are IPC/WHMA-A-62 or IPC-J-STD-1 certifi ed. This produces consistent, predictable products that protect signal integrity and ensures excellent transmission quality every time. Several variations of standard connector interfaces are available for this cable series. Weatherized (W) connector versions combine silicone seals and corrosion resistant stainless steel components to provide an impenetrable moisture barrier and long service life in outdoor installations. In addition, a rugged strain relief at the cable/connector junction comes standard to improves the dependability of these assemblies.. HIGH. WEATHEIZED Available jacket types for this cable are listed below with specifi c mechanical performance. UGGEDIZED. AMOED TEMPEATUE (H): Grey ETFE jacket with the highest available temperture rating. (Flame esistance and Low Smoke rating = UL94 V-) (W): Black polyurethane jacket with a lower temperture rating but improved fl exibility, high UV resistance and moisture sealed connectors. (Zero Halogen, Flame esistance and Low Smoke rating = UL94 V-). (): UltraFlex, stainless steel, interlocked casing with blue polyurethane jacket. This combines crush resistance with fl exibility and light weight. (A): Seamless, stainless steel, corrugated tube with stainless steel braid and black polyurethane jacket. This produces the highest crush resistance, torque resistance and tensile strength of all jacket options, but sacrifi ces fl exibility. Basic Cable Assembly Configuration : LENGTH LENGTH LENGTH DYNAWAVE DYNAWAVE DYNAWAVE DYNAWAVE Standard Electrical Testing includes VSW and Insertion Loss. Testing for other performance parameters such as phase and amplitude matching or special environmental conditions is available upon request. Standard Testing (1%) Optional Test (as required) Cable Assembly Electrical Specifications Specifications are subject to change without notice Max. Assembly VSW Max. Assembly Insertion Loss Phase Matching Phase Tracking See VSW Matrix Loss Calculator in Appendix (refer to page 2) < +/-.5 Deg. / GHz. < +/-.1 Deg. / GHz. / ft. Insertion Loss Matching + / - 3% DC - GHz. Connector End 1 Straight (Plug or Jack) ight Angle (Plug) Cable Assembly VSW Matrix Straight (Plug or Jack) 1.3 : 18 GHz : 26 GHz. 1.4 : GHz : 18 GHz. 1.4 : 26 GHz : GHz. Connector End 2 ight Angle (Plug) 1.35 : 18 GHz. 1.4 : 26 GHz : GHz. 1.4 : 18 GHz : 26 GHz. 1. : GHz. 19

30 Loss Calculations Freq. (GHz.) K1 K2 Cable Loss (db / in.) Connector Loss (db) Mismatch Loss Straight t. Angle VSW Loss (db) Attenuation = (K1 * freq. (GHz.)) + (K2 * freq. (GHz.)) Max. Assembly Loss = (Cable Loss) +(Connector #1 Loss + Connector #2 Loss) + (Mismatch Loss) Example : 37 inch long Cable Assembly, cable, with one straight and one right angle connector. Freq. = 12. GHz., VSW = 1.2 : 1. Insertion Loss = (37 x.212) + ( ) + (.4) =.9934 db. Cross eference by Dynawave Cross eference by Competitors Dynawave Cable 2 Competitors Harbour LL335 Insulated Wire 281 Micro Coax UFB293C Micro Coax UFB311A Semflex LA29 Times Microwave HF29 Times Microwave HF29s Harbour LL235 Insulated Wire 231 Micro Coax UFB197C Micro Coax UFB25A Times Microwave HF19 Times Microwave HF19s Insulated Wire 11 Insulated Wire 181 Micro Coax UFB142C Micro Coax UFB142A Times Microwave HF12 Times Microwave HF12s Competitors Harbour LL335 Harbour LL235 Insulated Wire 281 Insulated Wire 231 Insulated Wire 11 Insulated Wire 181 Micro Coax UFB293C Micro Coax UFB311A Micro Coax UFB197C Micro Coax UFB25A Micro Coax UFB142C Micro Coax UFB142A Semflex LA29 Times Microwave HF29 Times Microwave HF29s Times Microwave HF19 Times Microwave HF19s Times Microwave HF12 Times Microwave HF12s Dynawave Cable Specifications are subject to change without notice

31 DynaFlex Cable Series Series DF3 DC - 4 GHz. Application & Product Features This is Dynawave s best Light Weight F/Microwave interconnect cable series. Weight savings can be as much as 4% when compared to standard cables. The Series DF3 also features the ultra low density DynaCore PTFE dielectric and special light weight conductors which contribute to this series weight savings. A wrapped foil inner shield minimizes attenuation and makes the Series DF3 suitable for applications on Land, Sea, Mobile and Airborne Platforms in Static installations with radial torque forces less than 15 lb-in. Suitable for all applications where weight savings are the primary design concerns. Static installations on Land, Sea, Mobile and Airborne Platforms. Indoor and outdoor installations with exposure to sand, dust, sunlight and moisture. ecommended for Airframe, Antenna and Mobile Communication Systems Applications. Frequency ranges up to 4 GHz. Maximum temperature range -65 C to + 2 C (dependent on outer jacket option). Shielding effectiveness >1 db. Flexure life >1, cycles at 5x minimum bend radius. w w w. d y n a w a v e c a b l e. c o m

32 s with Cable Characteristics DynaFlex High Temperature DF318 DF326 DF34 Impedance (ohms) Velocity of Propagation (%) Min. Shield Effectiveness (db) Phase vs. Flexure Phase vs. Temperature Min. breakdown Voltage (KV) Capacitance (pf / ft.) Inductance (nh / ft.) Max. Operating Frequency (GHz.) Max. Structural VSW Max. Temperature (Deg. C ) Operating Temperature (Deg. C ) Jacket (in.) Second Shield O.D. (in.) First Shield O.D. (in.) Dielectric O.D. (in.) Solid Center Conductor O.D. (in.) Inside Min. Bend adius (in.) Flexure Life (5x Min. Bend adius) Weight (lbs. / ft.) : >1, See Graph (Pg. 23) See Graph (Pg. 23) : : 1-65 / / >1, >1,.3.1 Cable Construction & Specifi cations DynaFlex Series 3 cables incorporate silver plated, light weight conductors best suited for applications with less than 1, fl exures. Jacket Options, High Temp. : ETFE First Shield, Silver Plated Copper per ASTM B298 Solid Center Conductor Silver Plated Second Shield Silver Plated Dynacore Expanded PTFE Dielectric Type F per ASTM D4894 and D Specifications are subject to change without notice

33 Power, Attenuation & Phase Characteristics Power handling is specified for conditions at sea level and +25 degrees C. Use the de-rating chart to estimate average or peak power levels at other altitude or temperature conditions. For power ratings on cable assemblies see page 35. Power De-rating for Temp. & Altitude GHz Average Power ating (K Watts) DF318 DF326 DF Power vs Frequency % of ated Power Temp. Altitude Altitude (1's ft.) Temp. (Deg. C) K Watts DF318 DF326 DF GHz. Attenuation vs Frequency Attenuation (db/1 ft.) GHz. DF318 DF326 DF34 db/1 ft DF318 DF326 DF GHz K1 K Attenuation = (K1 * freq. (GHz.)) + (K2 * freq. (GHz.)) Phase vs Temperature Phase vs Flexure Temp (Deg. C) Specifications are subject to change without notice Phase Change (+/- Deg.) (See Eng. Note 1 on page 36) Phase Change (+/- Deg.) Phase change with 36 degree loop at the min. bend radius GHz. 23

34 Connector Specifi cations Dynawave connectors offer the best combination of price and performance. All connectors meet or exceed MIL-PF-3912 or MIL-STD-348 interface requirements and employ corrosion resistant stainless steel bodies, PTFE insulators, silicone gasket seals and gold plated BeCu contacts. These connectors utilize precision interfaces designed for greater than mating cycles without performance degradation. Cable Type SMA, Plug, Straight SMA, Plug, /A SMA, Jack, Bulkhead 2.4mm, Plug, Straight 2.4mm, Plug, /A 2.4mm, Jack, Bulkhead 2.92mm, Plug, Straight 2.92mm, Plug, /A 2.92mm, Jack, Bulkhead TNC, Plug, Straight TNC, Plug, /A TNC, Jack, Bulkhead N, Plug, Straight N, Plug, /A N, Jack, Bulkhead SC, Plug, Straight SC, Plug, /A SC, Jack, Bulkhead Connector Selection * DF H H H H H H H H H H H H-624 DF H H H H H H H H H H H H-624 DF H H H H H H-624 * We also offer the Design and Manufacture of Special Connectors to meet your requirements 24

35 DYNAWAVE Cable Assembly Specifi cations See page 34 to determine a Code for your requirement, or contact our factory for custom cable assemblies tailored to your specifications. Our 1% tested and factory certifi ed assemblies are manufactured with semi-automated assembly methods and statistical process controls. In addition, all soldering operations are IPC/WHMA-A-62 or IPC-J-STD-1 certifi ed. This produces consistent, predictable products that protect signal integrity and ensures excellent transmission quality every time. Several variations of standard connector interfaces are available for this cable series. In addition, a rugged strain relief at the cable/connector junction comes standard to improve the dependability of these assemblies. Available jacket types for this cable are listed below with specifi c mechanical performance attributes listed on page 34.. HIGH TEMPEATUE (H): Grey ETFE jacket with the highest available temperture rating. (Flame esistance and Low Smoke ating = UL94 V-). Basic Cable Assembly Configuration : LENGTH LENGTH LENGTH DYNAWAVE DYNAWAVE DYNAWAVE DYNAWAVE Standard Electrical Testing includes VSW and Insertion Loss. Testing for other performance parameters such as phase and amplitude matching or special environmental conditions is available upon request. Cable Assembly Electrical Specifications Cable Assembly VSW Matrix Standard Testing (1%) Optional Test (as required) Max. Assembly VSW Max. Assembly Insertion Loss Phase Matching Phase Tracking See VSW Matrix Loss Calculator in Appendix (refer to page 26) < +/-.5 deg. / GHz. < +/-.1 deg. / GHz. / ft. Insertion Loss Matching + / - 3% DC - 4 GHz. Connector End 1 Straight (Plug or Jack) ight Angle (Plug) Straight (Plug or Jack) 1.3 : 18 GHz : 26 GHz. 1.4 : 4 GHz : 18 GHz. 1.4 : 26 GHz : 4 GHz. Connector End 2 ight Angle (Plug) 1.35 : 18 GHz. 1.4 : 26 GHz : 4 GHz. 1.4 : 18 GHz : 26 GHz. 1. : 4 GHz. Specifications are subject to change without notice 25

36 Loss Calculations Freq. (GHz.) K1 K2 Cable Loss (db / in.) Connector Loss (db) Mismatch Loss DF318 DF326 DF34 Straight t. Angle VSW Loss (db) Attenuation = (K1 * freq. (GHz.)) + (K2 * freq. (GHz.)) Max. Assembly Loss = (Cable Loss) +(Connector #1 Loss + Connector #2 Loss) + (Mismatch Loss) Example : 37 inch long Cable Assembly, DF326 cable, with one straight and one right angle connector. Freq. = 12. GHz., VSW = 1.2 : 1. Insertion Loss = (37 x.216) + ( ) + (.4) = 1.82 db. Cross eference by Dynawave Cross eference by Competitors Dynawave Cable DF318 DF326 DF34 Competitors Micro Coax MCJ311A Micro Coax MCJ25A Micro Coax MCJ142A Competitors Micro Coax MCJ142A Micro Coax MCJ25A Micro Coax MCJ311A Dynawave Cable DF34 DF326 DF Specifications are subject to change without notice

37 DynaFlex Cable Series Series DF4 DC - 65 GHz. Application & Product Features This is Dynawave s Extreme Flexure F/Microwave interconnect cable series. The Series DF4 balances great electrical performance with fi nely tuned physical properties for dynamic fl exure in applications requiring up to, cycles. This series also features the low density DynaCore PTFE dielectric. A proprietary tri-shield construction includes two woven braids and a wrapped conductive tape for additional shielding. The Series DF4 is suitable for applications on Land, Sea and Mobile Communication where Dynamic installations are required. Suitable for all Dynamic Flexure applications requiring repetitive and extreme bend forces. Dynamic installations on Land, Sea, Mobile and Airborne Platforms. Indoor and outdoor installations with exposure to sand, dust, sunlight and moisture. Excellent for applications in adar Systems, Phase Array Antennas and Test & Measurement Systems. Frequency ranges up to 65 GHz. Maximum temperature range -65 C to + 2 C (dependent on outer jacket option). Shielding effectiveness >9 db. Flexure life >, cycles at 5x minimum bend radius. ecommended for high volume testing, anechoic chambers and antennas requiring repetitive motion or adjustments. w w w. d y n a w a v e c a b l e. c o m

38 s with Cable Characteristics DynaFlex High Temperature Weatherized DF412 DF418 DF426 DF44 DF4 DF465 DF412W DF418W DF426W DF44W DF4W DF465W Impedance (ohms) Velocity of Propagation (%) Min. Shield Effectiveness (db) Phase vs. Flexure Phase vs. Temperature Min. breakdown Voltage (KV) Capacitance (pf / ft.) Inductance (nh / ft.) Max. Operating Frequency (GHz.) Max. Structural VSW Max. Temperature (Deg. C ) Operating Temperature (Deg. C ) Jacket (in.) Third Shield O.D. (in.) Second Shield O.D. (in.) First Shield O.D. (in.) Dielectric O.D. (in.) Stranded Center Cond. O.D. (in.) Inside Min. Bend adius (in.) Flexure Life (5x Min. Bend adius) Weight (lbs. / ft.) : See Graph (Pg. 29) See Graph (Pg. 29) : : :1-65 / / : >, : : : See Graph (Pg. 29) See Graph (Pg. 29) :1 1.25:1-65 / / >, : : Cable Construction & Specifi cations DynaFlex Series DF4 cables offer an optional polyurethane jacket for excellent UV resistance in outdoor installations or for low smoke, halogen free jacket requirements. Stranded center conductors contribute to better fl exibility and are best suited for applications requiring up to, fl exures. Jacket Options, High Temp. (H) : ETFE Weatherized (W) : Polyurethane First Shield, Silver Plated Copper per ASTM B298 Stranded Center Conductor Silver Plated Copper per ASTM B298 Third Shield, Silver Plated Copper per ASTM B298 Dynacore Expanded PTFE Dielectric Type F Second Shield Conductive PTFE Tape 28 Specifications are subject to change without notice

39 Power, Attenuation & Phase Characteristics Power handling is specified for conditions at sea level and +25 degrees C. Use the de-rating chart to estimate average or peak power levels at other altitude or temperature conditions. For power ratings on cable assemblies see page 35. Power De-rating for Temp. & Altitude GHz Average Power ating (K Watts) DF412 DF418 DF426 DF Power vs Frequency DF DF % of ated Power Temp. Altitude Altitude (1's ft.) Temp. (Deg. C) K Watts DF412 DF418 DF426 DF44 DF4 DF GHz. db / 1 ft Attenuation vs Frequency Phase vs Temperature DF412 DF418 DF426 DF44 DF4 DF GHz. GHz K1 K2 Attenuation (db/1 ft.) DF412 DF418 DF426 DF44 DF Attenuation = (K1 * freq. (GHz.)) + (K2 * freq. (GHz.)) Phase vs Flexure DF Specifications are subject to change without notice Phase Change (ppm) Deg. C (See Eng. Note 1 on page 36) Phase Change (+/- Deg.) Phasechange with 36 degree loop at the minimum bend radius GHz. 29

40 Connector Specifi cations Dynawave connectors offer the best combination of price and performance. All connectors meet or exceed MIL-PF-3912 or MIL-STD-348 interface requirements and employ corrosion resistant stainless steel bodies, PTFE insulators, silicone gasket seals and gold plated BeCu contacts. These connectors utilize precision interfaces designed for greater than mating cycles without performance degradation. Connector Selection * Cable Type SMP, Jack, Straight SMPM, Jack, Straight SMA, Plug, Straight SMA, Plug, /A SMA, Jack, Bulkhead 1.85mm, Plug, Straight 1.85mm, Plug, /A 2.4mm, Plug, Straight 2.4mm, Plug, /A 2.4mm, Jack, Bulkhead 2.92mm, Plug, Straight 2.92mm, Plug, /A 2.92mm, Jack, Bulkhead TNC, Plug, Straight TNC, Plug, /A TNC, Jack, Bulkhead N, Plug, Straight N, Plug, /A N, Jack, Bulkhead SC, Plug, Straight SC, Plug, /A SC, Jack, Bulkhead DF412 DF418 DF426 DF44 DF4 DF H H H H H H H H H H H H H H H H H H H H H H H H-62 Note: 1.85mm Connectors are available upon request H H H H H H H H H H H H H H H H H H-62 Weatherized Connector Selection * Cable Type DF412W DF418W DF426W DF44W 2-4H H H H H H H H H H-62 DF4W 3-465H H H H-62 See Note See Note H H H H H H-62 DF465W SMA, Plug, Straight SMA, Plug, /A SMA, Jack, Bulkhead 1.85mm, Plug, Straight 1.85mm, Plug, /A 2.4mm, Plug, Straight 2.4mm, Plug, /A 2.4mm, Jack, Bulkhead 2.92mm, Plug, Straight 2.92mm, Plug, /A 2.92mm, Jack, Bulkhead TNC, Plug, Straight TNC, Plug, /A TNC, Jack, Bulkhead N, Plug, Straight N, Plug, /A N, Jack, Bulkhead SC, Plug, Straight SC, Plug, /A SC, Jack, Bulkhead * We also offer the Design and Manufacture of Special Connectors to meet your requirements W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W-62 See Note See Note W W W W W W-62 3

Times Microwave Systems Hermetically Sealed Assemblies

Times Microwave Systems Hermetically Sealed Assemblies SCOPE This Specification details the Electrical, Mechanical and Environmental Characteristics of Times Microwave Systems MILTECH 340.34 Diameter Hermetically Sealed Coaxial Transmission Lines. This product

More information

db MISER ULTRA LOW LOSS CABLE ASSEMBLIES Are you a design or test engineer fighting a challenging loss budget?

db MISER ULTRA LOW LOSS CABLE ASSEMBLIES Are you a design or test engineer fighting a challenging loss budget? db MISER ULTRA LOW LOSS ASSEMBLIES Are you a design or test engineer fighting a challenging loss budget? Consider db Miser ultra low loss cable assemblies. High performance materials, careful attention

More information

Precision Microwave Coaxial Cable Product Catalog. Connectivity for Business-Critical Continuity

Precision Microwave Coaxial Cable Product Catalog. Connectivity for Business-Critical Continuity Precision Microwave Coaxial Cable Product Catalog To our valued customers: Emerson Connectivity Solutions, provider of both Semflex and Midwest Microwave branded cable products, is unique among microwave

More information

Test and measurement cable assemblies

Test and measurement cable assemblies Test and measurement cable assemblies 1 Company Profile Simply Your Best Connection Technical information and sales contacts are available at : Radiall is a global leader in the design, development and

More information

Coaxial Cable Products Guide. Connectivity for Business-Critical Continuity

Coaxial Cable Products Guide. Connectivity for Business-Critical Continuity Coaxial Cable Products Guide Connectivity for Business-Critical Continuity The Difference Starts With The Cable BULK CABLES SLA Series Lowest loss cable available to 18 GHz, best choice for critical applications

More information

Test Cable Assemblies

Test Cable Assemblies Test Cable Assemblies and Coaxial Passive Components DC-65 GHz 8851 SW Old Kansas Ave. Stuart, FL 34997 USA +1-772-286-9300 +1-800-544-5594 sales@emc-rflabs.com www.emc-rflabs.com Premium Test Cable Lab-Flex

More information

SMA Interface Mating Dimensions (Per MIL-STD-348)

SMA Interface Mating Dimensions (Per MIL-STD-348) SMA Series SMA 6 SMA Interface Mating Dimensions (Per MIL-STD-348) SMA Interface Dimensions MALE Inches/Millimeters 3 Minimum Nominal Maximum LTR in. mm in. mm in. mm A.250 6.35.263 6.68.. B.1790 4.55.1808

More information

RF & Microwave cable assemblies C291

RF & Microwave cable assemblies C291 ERTIFIED C AS 9100 RF & Microwave cable assemblies C291 B CONTENTS Pages Introduction... B-4 Specify the right cable for your application... B-5 Finder guide cables vs insertion loss... B-6 to B-7 Flexible

More information

EMC Test Chamber Solutions RF Cable Assemblies and Connectors

EMC Test Chamber Solutions RF Cable Assemblies and Connectors EMC Test Chamber Solutions RF Cable Assemblies and Connectors RF CABLE ASSEMBLY AND CONNECTOR SOLUTONS FOR EMC MMUNTY AND EMSSON COMPLANCE TESTNG E X T N T R A T E D E P T H --> POWER LEVEL: -40.00 dbm

More information

PERFORMANCE AND VALUE FOR YOUR DAY-TO-DAY TEST APPLICATIONS.

PERFORMANCE AND VALUE FOR YOUR DAY-TO-DAY TEST APPLICATIONS. Rosenberger RFlex Cables PERFORMANCE AND VALUE FOR YOUR DAY-TO-DAY TEST APPLICATIONS. Features and Benefits Microwave test cable performance at a fraction of the cost Excellent performance over a broad

More information

Coaxial Cables for Medium-Frequency Applications

Coaxial Cables for Medium-Frequency Applications Coaxial Cables for Medium-Frequency Applications Coaxial Cables for Medium-Frequency Applications Introduction Telecommunications technology is moving forward rapidly and the need for fast and reliable

More information

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness Shielding Effectiveness Test Method Harbour s LL, SB, and SS Coaxial Cables Designs for Improved Shielding Effectiveness Harbour Industries 4744 Shelburne Road Shelburne Vermont 05482 USA 802-985-3311

More information

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes BNC 75Ω RF CONNECTORS BNC 75Ω RF CONNECTORS To meet the need for higher performance, impedance matched cable interconnections, Amphenol offers a full line of 75 ohm BNC connectors. These connectors can

More information

LOW LOSS CABLE PAG. 1

LOW LOSS CABLE PAG. 1 LOW LOSS CABLE PAG. 1 INTRODUCTION Following many requests we received regarding the need for low-loss custom cable assemblies, we have set up a special production of high performance coaxial cable assemblies

More information

RF cables. Edition 2015

RF cables. Edition 2015 RF cables Edition 2015 Developed for highest expectations Your partner for system solutions HUBER+SUHNER is a leading international producer and supplier of electrical and optical interconnectivity components

More information

Cable Assemblies. Cable Assemblies

Cable Assemblies. Cable Assemblies Cable Assemblies Cristek designs and manufactures semi-rigid and flexible microwave coaxial cable assemblies for interconnect and instrumentation applications from DC to 65 GHz. Contact Cristek early in

More information

Design Techniques for High Power RF Coaxial Cable Assemblies

Design Techniques for High Power RF Coaxial Cable Assemblies Design Techniques for High Power RF Coaxial Cable Assemblies Tony Martiniello Chief Technology Officer Primary Considerations Performance Electrical-Mechanical-Environmental Application Prioritizing-Trade-offs

More information

General Interconnect Range. High Phase Stability. Custom Solutions

General Interconnect Range. High Phase Stability. Custom Solutions General interconnect INTRODUCTION RADIALL, one of the world's leading manufacturers of coaxial connectors, has also been designing and manufacturing high performance coaxial cables and for more than 15

More information

Table of Contents. 4 General Information. 5 Definition of Parameters. 8 General Specifications. 9 Low Loss Cable Design and Construction

Table of Contents. 4 General Information. 5 Definition of Parameters. 8 General Specifications. 9 Low Loss Cable Design and Construction CABLE ASSEMBLIES Emerson Network Power Connectivity Solutions has a wide range of cable assemblies and connectors suited for RF, Microwave and Fiber Optic signal transmission. Connectivity Solutions is

More information

S-Level and Hi-Rel Connectors... 94. Power Rating for Coaxial Connectors... 98. Mounting Guidelines For Flange Mount Connectors...

S-Level and Hi-Rel Connectors... 94. Power Rating for Coaxial Connectors... 98. Mounting Guidelines For Flange Mount Connectors... Index... Page S-Level and Hi-Rel... 94 Power Rating for Coaxial... 98 Mounting Guidelines For Flange Mount... 102 Mating Microwave... 105 RF Versus Microwave SMA... 106 EMI/RFI Shielding Standards... 108

More information

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom The Quality Connection Cable Solutions for Mobile Networks Business Unit Telecom Connection Technology for Wireless Communication Systems A consistent focus on the market, in-depth sector and product knowledge,

More information

Mini-DINs. Low PIM Cable Assemblies and Coaxial Adapters. Always Thinking

Mini-DINs. Low PIM Cable Assemblies and Coaxial Adapters. Always Thinking TM Mini-DINs (4.1/9.5) Now Available Low PIM Cable Assemblies and Coaxial Adapters Always Thinking TM The remedy to the PIM problem In response to the growing problem that PIM presents to cellular base

More information

COAX Cables Radio Frequency Cables

COAX Cables Radio Frequency Cables COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions

More information

General Information. Lower Frequency Models Custom Designs Special Flanges Narrow Band Specials VSWR. Frequency ( GHz) COMMON SPECIFICATIONS

General Information. Lower Frequency Models Custom Designs Special Flanges Narrow Band Specials VSWR. Frequency ( GHz) COMMON SPECIFICATIONS Waveguide Adapters General Information DC - 26.5 GHz High Performance 1.15 Typical VSWR Male or Female Connectors available Choke Flange Types available -65 o C to +125 o C Operating Temperature Midwest

More information

ANOISON HPQN SERIES HPQN CONNECTORS INTERFACE DIMENSIONS. Description. Interface Dimensions 21 Characteristics

ANOISON HPQN SERIES HPQN CONNECTORS INTERFACE DIMENSIONS. Description. Interface Dimensions 21 Characteristics SERIES HPQN CONNECTORS DESCRIPTION CONTENT Designed by James Qu at Anoison in 2006, the HPQN is a quick locking version of the widely used type N connector. By replacing the threaded interface of the original

More information

SMA Connectors. RF Coax Connectors. Product Facts

SMA Connectors. RF Coax Connectors. Product Facts SMA Connectors Product Facts Performance to 12.4 GHz and beyond Available in various base metal options, including stainless steel, brass and zinc diecast Uses industry standard crimp tools and processes

More information

75 Ω Transmission System

75 Ω Transmission System NRAO NTC-DSL Laboratory Report Dynamic Spectroscopy Laboratory Report Series Report 03 September, 2006 75 Ω Transmission System Chaitali R. Parashare Department of Electrical and Computer Engineering,

More information

MICROWAVE & RF CABLE Semi-Rigid, hand-formable & flexible microwave cable

MICROWAVE & RF CABLE Semi-Rigid, hand-formable & flexible microwave cable MICROWAVE & RF CABLE Semi-Rigid, hand-formable & flexible microwave cable TABLE OF CONTENTS The Story of Micro-Coax...2-3 Microwave Cable Selection Guide...4-5 Semi-Rigid Coaxial Cable...5 UTiFORM Tin-Dipped

More information

I-PEX MHF4 Micro Coaxial Connector

I-PEX MHF4 Micro Coaxial Connector PRODUCT SPECIFICATION I-PEX MHF4 Micro Coaxial Connector Plug P/N 20448-001R-81 Receptacle P/N 20449-001E RF Connector, RF Cable & Antenna Manufacturer E-mail: sales@wellshow.com.tw Tel: +886-2-24239376

More information

MICROCABLES. A complete vision of your connectivity needs. Catalogue

MICROCABLES. A complete vision of your connectivity needs. Catalogue MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics

More information

Micro-Coax Specification. Cable Assemblies, UFB311A. Ultra Low Loss, 18.0 GHz

Micro-Coax Specification. Cable Assemblies, UFB311A. Ultra Low Loss, 18.0 GHz REVISIONS REV DESCRIPTION DWN APP C2 ECO 135440 NAP DMD Micro-Coax Specification Cable Assemblies, UFB311A Ultra Low Loss, 18.0 GHz Copyright Micro-Coax, Inc. THIS SPECIFICATION IS THE PROPERTY OF MICRO-

More information

Commercial Coaxial Cable

Commercial Coaxial Cable Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of

More information

Communication, Signal & Data Cables

Communication, Signal & Data Cables Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication

More information

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP

More information

Why is Passive Intermodulation Important?

Why is Passive Intermodulation Important? Precision Products for Demanding Applications Low PIM Products for Distributed Antenna Systems and Wireless Infrastructure Low PIM Coaxial Cable Assemblies Plenum Rated, Low PIM, Low Loss Coaxial Cable

More information

SMA Waterproof. Cable Assembly. Filtered Audio Connector. Dataport Receptacle. Dataport Plug

SMA Waterproof. Cable Assembly. Filtered Audio Connector. Dataport Receptacle. Dataport Plug INTERCONNECT SOLUTIONS FOR RUGGEDIZED COMMUNICATIONS GPS Antenna Gooseneck Adapter TNC Waterproof Cable Assembly Communication radios often carry critical public safety information and must operate reliably

More information

Standards Affecting a Premise T-1 Installation

Standards Affecting a Premise T-1 Installation Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity

More information

PCb Cable mount twinax. ConneCtorS

PCb Cable mount twinax. ConneCtorS PCb Cable mount twinax ConneCtorS technical CharaCteriStiCS SPeCiFiCationS temperature rating: -55 C to + 125 C Corrosion: MIL-STD-202 Method 101, Test Condition B Shock: MIL-STD-202 Method 213, Test Condition

More information

Discover. TIMES MICROWAVE SYSTEMS A Smiths Industries company

Discover. TIMES MICROWAVE SYSTEMS A Smiths Industries company Discover TIMES MICROWAVE SYSTEMS A Smiths Industries company Discover TIMES MICROWAVE SYSTEMS Discover... a coax cable with excellent RF performance, that's flexible and non-kinking with easy to install

More information

Sunridge MCB Series Miniature Coaxial Interconnect, 2.5mm or 2.0mm Mated Height

Sunridge MCB Series Miniature Coaxial Interconnect, 2.5mm or 2.0mm Mated Height Sunridge MCB series coaxial product fulfills the rigorous requirements of high frequency data transmission in digital world. Constructed in supreme Teflon coax cable and advanced mechanical design, MCB

More information

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY MICRO SFP+ CONNECTOR & CABLE ASSEMBLY micro SFP+ Connector and Cable Assembly TE Connectivity s (TE) micro SFP+ connector and cable assembly empower you to dream big when designing your communication system.

More information

Semi-rigid Coaxial Cables

Semi-rigid Coaxial Cables 50 Ohm RF Coaxial Cables Semi-rigid Coaxial Cables SR034 SR047/M17 SR086 /M17 SR086-25 SR086-75 SR090-25 SR141 SR141-25 SR141-35 SR141-75 SR250 SR250-75 147 Semi-rigid Coaxial Cabless SR034 Inner conductor

More information

Application Guide to RF Coaxial Connectors and Cables

Application Guide to RF Coaxial Connectors and Cables Application Guide to RF Coaxial Connectors and Cables By: Michael J. Hannon Product Applications Engineer and Pat Malloy, Sr. Applications Engineer There is a wide variety of coaxial connectors and cables

More information

CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.

CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc. CABLE 101 The Basics of Wire & Cable Copyright 2007, Belden Inc. KEY TERMS Insulations Jacket Capacitance Attenuation Velocity of propagation Dielectric strength Dielectric constant Working voltage Elongation

More information

ULTIMATE SNAP-N-SEAL

ULTIMATE SNAP-N-SEAL ULTIMATE SNAP-N-SEAL F Series Compression Connectors Thomas & Betts introduces the Ultimate Snap-N-Seal Compression Connector, the newest addition to the Snap-N-Seal system. Look for the classic design

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version

More information

Cables and Accessories Selection Guide

Cables and Accessories Selection Guide Cables and Accessories Selection Guide From data centers to robotics to patient monitoring equipment, we re committed to enabling the next generation of faster, smaller and smarter design. 3M offers an

More information

ETHERLINE Ethernet Cable, Connectors & Tools

ETHERLINE Ethernet Cable, Connectors & Tools Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary

More information

Micro-Coax Specification. Cable Assemblies, UFB142A. Low Loss, 40.0 GHz

Micro-Coax Specification. Cable Assemblies, UFB142A. Low Loss, 40.0 GHz REVISIONS REV DESCRIPTION DATE DWN APP A1 ECO 75386 7/11/07 SRP MKG Micro-Coax Specification Cable Assemblies, UFB142A Low Loss, 40.0 GHz Copyright Micro-Coax, Inc. THIS SPECIFICATION IS THE PROPERTY OF

More information

CELLFLEX Cable. www.rfsworld.com. SCF14-50 Series 1/4 Superflexible Foam Coax LINE PRODUCTS TRANSMISSION

CELLFLEX Cable. www.rfsworld.com. SCF14-50 Series 1/4 Superflexible Foam Coax LINE PRODUCTS TRANSMISSION SCF4-50 Series /4 Superflexible Foam Coax OEM jumpers, BTS inter-cabinet connections, GPS lines, Riser-rated In-Building (JFN types) Foam-Dielectric, Superflexible Size /4 Copper-Clad Aluminum Wire Diameter

More information

Uniprise Solutions COAX 101. White Paper. www.commscope.com

Uniprise Solutions COAX 101. White Paper. www.commscope.com Uniprise Solutions COAX 101 White Paper www.commscope.com Structured cable systems have very thorough standards for fiber optic and twisted pair installations. The cabling components and installed systems

More information

Index. 2.40 mm Connector Series. 2.40 mm Connectors (50 GHz)... Page. Interface Standards... 44. Specifications... 45. Connector Numbers...

Index. 2.40 mm Connector Series. 2.40 mm Connectors (50 GHz)... Page. Interface Standards... 44. Specifications... 45. Connector Numbers... Connector Series Index (50 GHz).... Page Interface Standards... 44 Specifications... 45 Connector Numbers... 46 Typical Test Data... 48 End : can be found in the Adapter section. : can be found in the

More information

C ole s quality Open Frame Instrument Rotary Switch provides low

C ole s quality Open Frame Instrument Rotary Switch provides low OPEN FRAME series C ole s quality Open Frame Instrument Rotary Switch provides low contact resistance (.005W), very high contact reliability, smooth action with positive positioning, precision design,

More information

spinner Measurement & Calibration equipment for network analyzers

spinner Measurement & Calibration equipment for network analyzers spinner Measurement & Calibration equipment for network analyzers Edition B 2011 High Frequency Performance Worldwide www.spinner-group.com SPINNER test & calibration equipment for best measurement results

More information

6000 Series Buccaneer

6000 Series Buccaneer Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available

More information

COAXICON Contacts. RF Coax Connectors. Product Facts

COAXICON Contacts. RF Coax Connectors. Product Facts COXICON Contacts Product Facts Tyco Electronics provides a variety of contacts for coaxial connectors Contacts are available in a range of sizes that may be used with the various types of coaxial cable

More information

SMA Series Subminiature RF Connectors

SMA Series Subminiature RF Connectors SMA Series Subminiature RF Connectors Screw-on mating Frequency range DC-18 GHz High performance Rugged construction ONLINE CATALOG 104 John W. Murphy Drive P.O. Box 510 New Haven, CT 06513 www.aepconnectors.com

More information

coaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable

coaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable COAXIAL CABLE coaxial Cable 100% certified coaxial cable coaxial cable CERTIFIED The step ahead undertaken by Televés to improve its service and technical excellence, is now reflected in this new challenge.

More information

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS . HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or

More information

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored

More information

ENGINEERING COMMITTEE

ENGINEERING COMMITTEE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 02 2006 Specification for F Port, Female, Indoor NOTICE The Society of Cable Telecommunications Engineers (SCTE)

More information

STANDARD MICRO-D CONNECTORS

STANDARD MICRO-D CONNECTORS STANDARD MICRO-D CONNECTORS RECTANGULAR CONNECTORS Pigtail connector - Metal shell.............................. 56 Pigtail connector - Low profile - Metal shell.................... 58 Pigtail connector

More information

Passive Intermodulation Distortion in Connectors, Cable and Cable Assemblies

Passive Intermodulation Distortion in Connectors, Cable and Cable Assemblies Passive Intermodulation Distortion in Connectors, Cable and Cable Assemblies David Weinstein Amphenol Corporation Communication and Network Products One Kennedy Avenue Danbury, CT 06810 Introduction: Although

More information

Gulf Cable & Electrical Ind. Co.

Gulf Cable & Electrical Ind. Co. CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS

More information

Selecting a Transmission Line for Your Broadcast System

Selecting a Transmission Line for Your Broadcast System Selecting a Transmission Line for Your Broadcast System Introduction This Bulletin presents the procedures broadcasters need for calculating attenuation and power handling parameters to properly design

More information

Cables. Accessories. For Force, Torque and Strain Sensors

Cables. Accessories. For Force, Torque and Strain Sensors Accessories Cables For Force, Torque and Strain Sensors Charge mode, high impedance piezoelectric measurement demands highly insulated coaxial cables and connectors to ensure an insulation resistance greater

More information

TELECOM The Newsmagazine of the Industrial Telecommunications Association, Inc.

TELECOM The Newsmagazine of the Industrial Telecommunications Association, Inc. VOLUME 8 ISSUE 5 2000 TELECOM E X C H A N G E The Newsmagazine of the Industrial Telecommunications Association, Inc. Connecting Coaxial Cable Key to Radio System Deployment By Lou Caruso Times Microwave

More information

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip. Each dielectric configuration has different high-frequency characteristics. All configurations

More information

Universal MATE-N-LOK Connectors

Universal MATE-N-LOK Connectors Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00

More information

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2

More information

KNOW YOUR OPTIONS: 230 KV POWER CABLES

KNOW YOUR OPTIONS: 230 KV POWER CABLES KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common

More information

Cables. Indoor, Outdoor, HDMI, CAT, connectors. Cables, connectors and tools

Cables. Indoor, Outdoor, HDMI, CAT, connectors. Cables, connectors and tools Indoor, Outdoor, HDMI, CAT, connectors, connectors and tools Indoor Outdoor Fly leads HDMI CAT F -/IEC connectors F -/IEC adaptors F - terminator Connection cables Power cables and electricity articles

More information

WAVEGUIDE COMPONENT Specifications and Design Handbook. Edition #7

WAVEGUIDE COMPONENT Specifications and Design Handbook. Edition #7 WAVEGUIDE COMPONENT Specifications and Design Handbook Edition #7 CONTINENTAL MICROWAVE DIVISION Integrated Waveguide Assemblies Waveguide components are just the beginning. Continental Microwave Division

More information

Specification SFTP CAT6 Network Cable 23AWG CU

Specification SFTP CAT6 Network Cable 23AWG CU Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)

More information

Siemens Energy & Automation. structured. WIRING Product Training Series: Advanced Video Session 3

Siemens Energy & Automation. structured. WIRING Product Training Series: Advanced Video Session 3 s structured WIRING Product Training Series: Advanced Video Session 3 1 Table of Contents This presentation will give you a closer look at Video in Structured Wiring applications. The following Areas will

More information

Broadcast and Commercial AV Cabling MASTER CATALOG

Broadcast and Commercial AV Cabling MASTER CATALOG Broadcast and Commercial AV Cabling MASTER CATALOG Clark Wire & Cable 408 Washington Blvd. Mundelein, IL 60060 800-222-5348 toll free 847-949-9944 local 847-949-9595 fax www.clarkwire.com Specifications

More information

Solving Signal Problems Effective shielding is key to enhancing the reliability and performance of broadcast cables.

Solving Signal Problems Effective shielding is key to enhancing the reliability and performance of broadcast cables. Solving Signal Problems Effective shielding is key to enhancing the reliability and performance of broadcast cables. by Marty Van Der Burgt Belden Article for Broadcast Engineering There is perhaps no

More information

Coaxial Cables and Applications Contributed By: Martin J. Van Der Burgt Senior Product Engineering Project Manager, Belden Electronics Division

Coaxial Cables and Applications Contributed By: Martin J. Van Der Burgt Senior Product Engineering Project Manager, Belden Electronics Division Coaxial Cables and Applications Contributed By: Martin J. Van Der Burgt Senior Product Engineering Project Manager, Belden Electronics Division Overview: Coaxial cables are perhaps the most common, basic,

More information

RF Connector Solutions

RF Connector Solutions RF Connector Solutions C o n n e c t i n g I n n o v a t i o n t o A p p l i c a t i o n Winchester Electronics was established in 1941 and is today a global leader in the design, development, and deployment

More information

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification

More information

N type Coaxial Connectors

N type Coaxial Connectors N type Coaxial Connectors N Series Features 1. 50 ohms wide varieties standard connectors 2. Screw on locking 3. High durability 4. Applicable standard: MI-C-39012/MI STD 348-304 Products guide s Straight

More information

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both

More information

ELECTRICAL CHARACTERISATION OF SEMI-RIGID COAXIAL CABLES WITH SMA AND K CONNECTORS. Carmen Diez Rafael García Juan Daniel Gallego.

ELECTRICAL CHARACTERISATION OF SEMI-RIGID COAXIAL CABLES WITH SMA AND K CONNECTORS. Carmen Diez Rafael García Juan Daniel Gallego. ELECTRICAL CHARACTERISATION OF SEMI-RIGID COAXIAL CABLES WITH SMA AND K CONNECTORS March 2005 TECHNICAL REPORT C.A.Y. 2005-4 ABSTRACT Semi-rigid coaxial transitions are normally used in closed cycle refrigerators

More information

SPECIALTY CABLES APPLICATIONS SUPPORTED

SPECIALTY CABLES APPLICATIONS SUPPORTED SPECIALTY CABLES A leader and innovator of specialty cable designs; EMTEQ delivers proven products that interface with a variety of applications onboard the aircraft. With designs targeting keys areas

More information

Outside Plant Precision Cooling Site Monitoring and Services

Outside Plant Precision Cooling Site Monitoring and Services Emerson Network Power Connectivity Solutions Johnson 299 Johnson Avenue Waseca, MN 56093 USA Tel: 800.247.8256 Fax: 507.833.6287 www.emersonnetworkpower.com/connectivity About Emerson Network Power Connectivity

More information

Section 5 161 kv Power Cables

Section 5 161 kv Power Cables Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper

More information

08. SEK IDC CONNECTORS

08. SEK IDC CONNECTORS . IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these

More information

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL* Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly

More information

Between Series Adapters

Between Series Adapters Between Series Adapters Between Series Coaxial Transmission Line Adapters provide convenient transitions between popular series coaxial connectors. The adapter design provides a minimum length consistent

More information

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits INTRODUCTION The Radiall Type 43 coaxial connector range The Radiall range of Type 43 series connectors is fully approved (where applicable) to BT (British Telecom) standards as well as to British Standard

More information

Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32

Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32 Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud

More information

CONFLEX ELECTRIC CABLE

CONFLEX ELECTRIC CABLE CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard

More information

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW Complete One Stop Solution for OPGW Cable and Fittings for OPGW 53, Justice Chandra Madhav Road, Kolkata - 700020. India. Phone: 91-33-24748575 / 7565 Fax: 91-33-2476-1955 Email: sales@supremeco.com Website:

More information

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE

More information

Outside Telephone Cable

Outside Telephone Cable Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of

More information

Interconnect Solutions For Global Technology

Interconnect Solutions For Global Technology The PHOENIX Company of Chicago TM Interconnect Solutions For Global Technology z RF/Microwave Cable Assemblies z Coax Connectors z Blind Mate Connectors z Integrated Products z Molded Cable Assemblies

More information

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

More information

Directory chapter 04

Directory chapter 04 M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................

More information

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission

More information

SPEC 55. Wire and cable. Applications. SPEC 55PC wire and cable insulation system. Features and benefits. Physical characteristics

SPEC 55. Wire and cable. Applications. SPEC 55PC wire and cable insulation system. Features and benefits. Physical characteristics SPEC 55 Wire and cable Applications SPEC 55 wire is insulated with modified radiation cross-linked ETFE polymer. It has a temperature rating of -65 C to 200 C continuous using a silver plated copper conductor,

More information