Falk True Torque Fluid Couplings
|
|
|
- Wesley Nelson
- 9 years ago
- Views:
Transcription
1 Fluid Catalog Download the most up-to-date versions at Falk True Torque Fluid s (Inch)
2 2 ( )
3 Table Of Contents Description Page Rexnord Fluid Benefits...4, 5 Principles of Operation...6, 7 Basic Types Accessories for Overload Protection and Prevention of Fluid Discharge... 9 Other Accessories Selection How to Select Mounting Arrangements Fluid Identification Quick Selection HFN & HFD for Belt Conveyors Quick Selection HFDD for Belt Conveyors Quick Selection General Duty (Other than Belt Conveyors)... 16, 17, 18, 19 s and Dimensions HFN20 Gear Mount (Non Delay Fill) HF20 Gear Mount (with Delay Fill Chamber) HF31, 31-1 Steelflex /Hollow Shaft Mount HF32, 32-1 Steelflex/Hollow Shaft Mount HF25 Disc Mount HF132 & Tschan/Hollow Shaft Mount HF41 Sheave/Hollow Shaft Mount... 26, 27, 28, 29 Technical Data Engineering Data Fluid Recommended Fluids ( ) 3
4 Rexnord Fluid Benefits Soft Cushioned Starts Without the fluid coupling, the motor instantly transmits its locked rotor torque (starting torque) to the driven machine (point A at right). Then, it quickly reaches and applies the breakdown torque (point B). For common applications, locked rotor and breakdown torque often approximates 200% or more of the motor nameplate rating. Damage can result if the required break-away starting torque of the driven machine is significantly less, because the machine will be abruptly accelerated to rated speed. With a fluid coupling installed, however, the torque to the driven machine starts at zero (point C) and gradually increases as the coupling impeller accelerates to point D. When the output torque of the fluid coupling exceeds the break-away starting torque of the driven machine (point D), the driven machinery gradually accelerates (right half of chart). As the machine comes up to rated speed, the slip of the fluid coupling decreases to (point E) and uniform power is transmitted at maximum efficiency. Increased Starting Torque With a fluid coupling, the breakdown torque of a standard NEMA B squirrel cage motor can be used to provide additional torque to start the machinery. In this example of a high-horsepower application, the NEMA B motor will initially exert only 80% of its rated torque (point A). Only if the motor can accelerate to 85% of its synchronous speed can it take advantage of its 175% breakdown torque (point B). However, with a properly selected fluid coupling, the motor can start under no load (point C), and reach its breakdown torque in only a few shaft revolutions. If a fluid coupling is not utilized, an oversized motor or a special high-starting-torque motor may be required. These solutions are costly and introduce undesirable variables into the system. A properly-selected and filled fluid coupling can provide an initial starting torque ideally matched to the needs of the driven machine. Attainable initial starting torque values range from 40% of normal running load minimum, up to a maximum initial starting torque value that equals the full breakdown torque of the motor. Overload Protection When a machine jams, the life of individual components may be drastically reduced. Without overload protection, the stored energy of the machine is absorbed in the first second following the jam, increasing stresses on components to many times their normal running values. The fluid coupling slip characteristics spread the absorption of the impact over a period of time, reducing stress on the components and therefore protecting your machinery. Safety Notes Install and operate Rexnord products in conformance with applicable local and national safety codes and per Rexnord installation manuals which are shipped with fluid couplings and are also available upon request. Suitable guards for rotating members may be purchased from Rexnord as optional accessories. Consult your local Rexnord district office for complete details. People Conveying Equipment Selection of Rexnord gear drives for applications whose primary purpose is the transportation of people is not approved. This includes such applications as freight or passenger elevators, escalators, man lift platforms, and ski tows and ski lifts. If the primary purpose of the application is material conveyance and occasionally people are transported, the Rexnord warranty may remain in effect, provided the design load conditions are not exceeded and certification to the appropriate safety codes and load conditions has been obtained by the system designer or end user from the appropriate enforcement authorities. Speed Variation of Multi-Speed Applications Fluid couplings offered in this catalog are designed to operate on single-speed applications, i.e. the motor driving the fluid coupling is started, accelerates to its base speed, and is not subject to speed variation about its base speed. The operating characteristics of a fluid coupling (a centrifugal device) are dependent on the speed of the coupling, and in particular, reduction in speed from those conditions identified in the selection tables will cause diminishing performance. All variable speed or multi-speed applications should be referred to the Factory to determine whether a fluid coupling is suitable for the application. Warranty The warranty period for Fluid s is 1.5 years from date of shipment. The description of what is covered by this warranty is found in Rexnord s General Conditions & Terms/Standard Conditions of Sale. 200 T A O R Q U E % 100 T O R Q U E % T O R Q U E M AG N I T U D E C MOTOR SPEED % A C MOTOR ACCELERATION B B D 200 E MOTOR SPEED % MACHINE RESISTIVE TORQUE MACHINE SPEED % MACHINE ACCELERATION NORMAL RUNNING LOAD TIME-SECONDS 4 ( )
5 Rexnord Fluid Benefits Reduced Current Draw When Starting The electric current draw at start-up is dramatically reduced when a fluid coupling is present. The motor starts without any meaningful load yet applied by the driven machinery (point A, Figure 1). In the absence of load, the motor quickly accelerates to approximately 90% of its full load speed (point B, Figure 1). The result is that low current draw (point C, Figure 1) is achieved within several shaft revolutions. At this point the inertia of the motor has been accelerated, and the application of load from the driven machine will not cause subsequent periods of high inrush current. With a fluid coupling, the duration of high current draw is reduced substantially as shown in the shaded area of Figure 2. This results in electrical savings and extended service life of the motor. Accessories Provide Non-discharging Protection Against Overload If a jam occurs without a fluid coupling, the motor will stall, draw over 500% of full load current (point A), and possibly burn out. Furthermore, mechanical impact forces of even greater magnitude can be generated which can damage the driven machine. With a properly selected fluid coupling, the motor speed will lug down only to the intersection of the motor torque and 100% slip curve of the fluid coupling (point B). Therefore, the current draw of the motor will only rise to point C. If the overload or blockage is removed, the drive will resume its normal torque and speed. If not removed, the coupling fluid temperature will rise, causing the fusible plug to melt. This disconnects the torque from the driven machine. In lieu of a fusible plug, consider a proximity sensor cutout switch, or a non-discharging thermal trip plug and thermal trip switch. See page 9 for details. Load Balancing for Multiple Drives Loads can be easily balanced on multiple drive systems when fluid couplings are installed at each motor. Refer to the illustration at the right of two motors, each equipped with a fluid coupling. Load sharing between the two motors has been achieved by appropriately adding fluid to one coupling or withdrawing fluid from the other coupling. As an added benefit, motors on multiple drive systems can be individually started because of the ability of one coupling to temporarily operate at 100% slip. Starting one motor at a time provides extended and even softer starts on multiple drive conveyors. Since the motors are started as separate events, the system maximum inrush current will be approximately half the system maximum inrush current experienced when both motors are started simultaneously. Load Dampening A fluid coupling dampens shock and vibratory load to maximize equipment life. M 600 OT M O 500 O 600 R T O C R 500 UR 400 C U R RR 400 E N 300 E T N T 300 REDUCTION & 200 & OF C T B 200 CURRENT O T O R 100 R Q Q 100 U U E E A % % MOTOR SPEED % TIME M OT O R C UR R E N T & T O R Q U E % 600 A RPM MOTOR MOTOR SPEED % 3600 lb-in (407 Nm) Figure 1 Figure 2 3.2% SLIP 1694 RPM C 63 RPM 63 RPM B HEAD 3.4% SLIP 1694 RPM 3600 lb-in (407 Nm) 1754 RPM MOTOR 100,000 lb-in 100,000 lb-in ( ) 5
6 Principles of Operation Introduction The working circuit is defined by the Casing, Impeller and Runner. A conical baffle is attached to the Impeller, and a flat baffle is attached to the Runner. The Impeller and Runner each represent half of a hollow torus, each with flat radial vanes. Torque transfer takes place as follows. Driving End (Input) mechanically transfers torque to the Casing. Casing mechanically transfers torque to the Impeller. Impeller transfers torque, via the fluid, to the Runner. Runner mechanically transfers torque to the Shaft. Shaft mechanically transfers torque to the Driven End (Output). The Runner has no mechanical connection to the Impeller. These two components are connected by the energized fluid. If you rotate the Driving End (Input) by hand, the Driven End (Output) does not rotate. Fluid couplings are furnished without fluid. Customer-supplied fluid is added during installation. FLAT BAFFLE CASING RUNNER IMPELLER WORKING CIRCUIT CONICAL BAFFLE DRIVING END (INPUT) DRIVEN END (OUTPUT) CONICAL BAFFLE FLAT BAFFLE Starting Standard NEMA B motors are recommended when using fluid couplings and will start virtually unloaded. Since the motor is mechanically connected to the impeller and casing, the low inertia of these components and the fluid are the only loads imposed. As the electric motor accelerates to running speed, the impeller begins to centrifugally pump fluid to the stationary runner. Initial dispersion of fluid is de-concentrated by the conical impeller baffle, producing a gradual increase in torque, allowing the motor to accelerate rapidly to full running speed. When all the fluid is pumped into the working circuit, continuous circulation of fluid will occur between the impeller and runner. A flow path is formed, shaped like a helical coil that is joined into a closed ring. As soon as the transmitted torque reaches the value of the load breakaway torque, the runner starts rotating and accelerates the driven load. The time required to reach full speed is dependent on the inertia of the driven load, the resistive torque and the torque being transmitted by the fluid coupling. AT REST Running The operation of a fluid coupling is based on hydrokinetic principles and requires that the output speed be less than the input. This difference in speed is called slip. Further, this principle provides that the output torque is equivalent to the input torque. Therefore, efficiency equals 100% minus the percent of slip. At full running speed, fluid couplings will normally slip between 1% and 4%. The fluid circulation between the impeller and runner has formed a helical coil at the outside circumference of the working circuit and is no longer de-concentrated by the conical baffle. STARTING RUNNING 6 ( )
7 Principles of Operation Overload Stall If the load torque increases, the slip will increase, which causes the runner to drop in speed. The coil of fluid circulating between the impeller and runner will expand to provide additional torque. The extent to which this coil can expand is limited by the flat baffle on the runner. Consequently fluid couplings provide inherent overload protection. If the increase in torque causes the fluid in the working circuit to expand to the point of contacting the baffle, the coupling will stall and slip will be 100%. This continuous high slip generates heat and the fluid temperature will rise unless the overload is removed. When the temperature rises to the temperature limit of the fusible plug, the core of the plug will melt, releasing fluid from the coupling and effectively disconnecting power to the output shaft. To prevent the discharge of fluid, the use of a proximity cutout switch or thermal trip plug and limit switch is recommended, see page 9. guards must be designed to permit the free flow of air for cooling the fluid coupling and to contain fluid discharge from fusible plug(s) in the event of a sustained overload. Consider Falk Orange Peel coupling guards, which are ideally suited for this purpose. Belt Conveyors Superior Soft Start Delay Fill (HFD) and Extended Delay Fill (HFDD) The starting torque that can be transmitted by a fluid coupling is a function of the amount of fluid in the working circuit at start. The delay fill chamber with metering orifice option, bolted to the driving end of s 1420HF thru 2870HF fluid couplings, permits a portion of the fluid to drain out of the working circuit and into the delay chamber, when the coupling is at rest. This reduction of fluid in the working circuit at start-up provides an ideal method to assure superior soft start for belt conveyors and is effective for starting belts that are loaded or unloaded. Upon starting, and once the electric motor has accelerated the fluid coupling to appreciable speed, the fluid in the delay chamber is slowly metered into the working circuit by virtue of the three metering orifice plugs shown below, gradually increasing the transmitted torque. The time required to completely empty the delay chamber can range from 15 to 60 seconds. Rexnord offers delay fill (HFD) and extended delay fill (HFDD). These solutions provide longer, softer starts, while providing higher efficiencies at full operating speeds. NORMAL RUNNING CONDITION FLUID FLOW ABOVE BAFFLES DRIVER 1775 RPM INCEPTION OF OVERLOAD/STALL FLUID FLOW DROPS CONTACTING BAFFLES AND REDUCING TORQUE DRIVER 1775 RPM DRIVEN 1750 RPM DRIVEN 0 RPM TYPE HFD DELAY FILL TYPE HFDD EXTENDED DELAY TYPE HFDD EXTENDED DELAY FILL AT REST AT REST RUNNING DELAY FILL CHAMBER EXTENDED DELAY FILL CHAMBER EXTENDED DELAY FILL CHAMBER SIZES 1420 & LARGER TYPES HFD & HFDD METERING ORIFICES DETERMINE FLOW RATE FROM FILL CHAMBER TO WORKING CIRCUIT EXTERNAL ACCESS PLUG (3) EQUALLY SPACED REPLACEABLE METERING ORIFICE (3) EQUALLY SPACED ( ) 7
8 Basic Types Non Delay Fill (HFN) and Inactive Delay Fill (HFR) Soft, cushioned start with a short delay in the acceleration of the load (Example: 5 seconds) Satisfactory soft start for many common applications Best choice for overload protection (page 4) Good choice for increased starting torque (page 4) All fluid remains in the working circuit HFR (plugged delay fill chamber) furnished when HFN not available Delay Fill (HFD) Softer, more cushioned start with longer delay in the acceleration of the load (Example: 12 seconds) Excellent choice for belt conveyors and other applications calling for sophisticated soft start Incorporates delay fill chamber At start, the working circuit has reduced fill. Fluid from the delay chamber is metered into the working circuit during acceleration. Provides overload protection Extended Delay Fill (HFDD) Softest, most cushioned start of empty belt conveyors and longest delay in the acceleration of the load (Example: 20 seconds) Superior choice for high end belt conveyors, low inertia applications and starting of empty belts Incorporates extended (enlarged) delay fill chamber At start, the working circuit has least fill. Fluid from the extended delay chamber is metered into the working circuit during acceleration. RUNNER IMPELLER RUNNER IMPELLER RUNNER IMPELLER DRIVING END DRIVEN END DRIVING END DRIVEN END DRIVING END DRIVEN END DELAY FILL CHAMBER EXTENDED DELAY FILL CHAMBER Choosing the Right Basic Type The information above, along with the Quick Selection Tables, enables you to choose the most appropriate basic type of fluid coupling. Where required, Rexnord can provide engineered fluid coupling selections based on the demand horsepower and WR 2 of your mechanical system. Fluid Does the Work At start-up centrifugal force and impeller vane action pump the working fluid against the runner, building torque and speed to match the motor capabilities with the driven machine requirements. Standard Features hp capacity No contacting surfaces to wear out Efficiencies to 99% Bolted (not welded) construction for simple rebuilds High-temperature Viton seals for long life Internal baffles for soft starts and stalls 2 fusible overload plugs, 140 C/200 C for maximum protection Fill angle finder makes setup easy Externally-changeable metering orifices (1420 & larger) Standard delay chambers (370 & larger) Extended delay chambers (370 & larger) 8 ( )
9 Accessories for Overload Protection and Prevention of Fluid Discharge Proximity Sensor Cutout Switch The actual speed of the driven shaft is continuously compared to the pre-set cutout speed. The switch includes an adjustable speed control box for manual setting of the cutout speed, usually 80% of normal operating speed. During overload, the instant the driven shaft speed drops below the cutout speed, the cutout switch opens the motor starter circuit, disconnecting the motor electrical supply. To start the system after the overload is removed, press the start button and hold it until the driven shaft speed exceeds the cutout speed. If the overload has NOT been removed, the starter circuit will again open and shut down the motor when the start button is released because the driven shaft did not exceed the cutout speed. Nothing needs to be replaced or repaired. For Type HF20, the sensor target can be placed on the output half of the gear coupling. For Types HF31, 31-1, 32 and 32-1, the sensor target would be attached to a shaft on the output side of the fluid coupling. For the HF41, the sensor target would be attached to the end of the fluid coupling opposite the sheave. For a full description of the proximity sensor cutout switch, see Service Manual SENSOR TARGETS AT 180 DRIVEN AIR GAP SENSOR TARGETS SENSOR SUPPORT BRACKET SENSOR HEAD JAM NUT Thermal Trip Plug & Thermal Trip Switch Fluid discharge can be prevented by using an optional thermal trip plug in place of the standard fusible plug. When the fluid temperature exceeds a predetermined value, a pin extends to trip a limit switch and cut out the motor. Thermal trip plugs are available in temperatures of 140 C and 180 C. The drive can be reactivated by resetting the motor cutout and replacing the trip plug. NOTE: For the Type HF41 sheave coupling design (or any reverse-mounted fluid coupling), the thermal trip plug/limit switch prevents fluid discharge due to overheating caused by excessive slippage, where the coupling slows down, but does not stall. In this case the trip plug will still rotate and trip the switch in the event of overheating. If the requirement is to trip a switch in the event of a total jam in the system (outer case of fluid coupling at zero rpm and plug cannot rotate through switch), use the proximity sensor cutout switch above. For a full description of the thermal trip plug and thermal trip switch, see service manual THERMAL TRIP PLUG SWITCH Orange Peel Guards Rexnord Orange Peel Guards offer a convenient, economical enclosure for rotating couplings. ➀ Fluid Orange Peel Guard Selection ➀ 185HF CFCG30 235HF CFCG40 270HF CFCG40 320HF CFCG50 370HF CFCG HF HF See Orange Peel Catalog >1660HF Refer to the Factory Review site conditions versus guard dimensions to assure proper clearances for guard are present. Orange Peel Guard ( ) 9
10 Other Accessories Angle Finder (Part No ) Each fluid coupling is shipped with an angle finder. Reorder in case of loss or damage. The angle finder will ease the task of filling the fluid coupling to the specified fill angle. Setup time is reduced, because the angle finder is direct-reading. Simply place the angle finder on the filler plug boss and rotate the coupling to the required fill angle. Provide Soft Start Plus Holdback or Control the Overrun Tendencies of Specific Applications Fluid /Disc Brake Package Fluid coupling/disc brake packages are versatile designs that can be customized to meet your specific needs. The superior performance inherent in disc brakes, combined with the benefits of a fluid coupling, provide an ideal package for inclined conveyors where soft start and holdback are required for the process of moving loads from a lower elevation to a higher elevation. The package consists of a fluid coupling and a Type G63 coupling (gear coupling with brake disc incorporated). The brake disc is designed to be compatible with hydraulic calipers that are actuated by a factory-supplied hydraulic power pack. In the illustration below, the G63 mounting of the brake disc is shown. Note that application of the brake takes place at the output side of the fluid coupling. This arrangement assures that braking is applied directly to the driven shaft. The use of a fluid coupling/brake disc package to retard over-running tendencies associated with specific applications or to retard eccentric loads that tend to roll back to a neutral centered position requires significant analysis and should be referred to the Factory. TYPE G63 FLUID COUPLING WITH GEAR COUPLING AND BRAKE DISC DRIVING END (INPUT) DRIVEN END (OUTPUT) HYDRAULIC POWER PACK (REXNORD SUPPLIED) ALSO AVAILABLE IN NON-LUBRICATED DISC COUPLING VERSION (Type FD63) 10 ( )
11 Selection How to Select The fluid coupling is a multiple-use device: Provides soft, cushioned starts Provides increased starting torque Provides overload protection Reduces current draw when starting Provides load balancing for multiple drives Provides load dampening To achieve these objectives, use a standard NEMA B motor with sufficient breakdown torque to start the machinery and with adequate continuous rating for the normal continuous load. The function of the fluid coupling is to allow the motor to come up to speed with minimum load. The fluid coupling is selected on the basis of the full load running horsepower as well as the torque required to start the load. In some applications, such as belt conveyors, it may be desirable to limit the maximum starting torque. If possible, select the coupling on the basis of the load rather than the motor rating, especially if the motor is oversized. s that are selected on the basis of the motor size will have starting torque and maximum overload torques in relation to the motor rating. Selection Procedure 1. Determine the running load horsepower (preferred) or the motor horsepower. 2. Choose a Start Factor from the Table below. Start Factor: the ratio of a pertinent starting torque to the running load torque (the torque required to maintain the load (speed) once equipment has been accelerated to its design speed). For belt conveyors select from pages 14 and 15. Start Factor is the average starting torque exerted by the fluid coupling during load acceleration, expressed as a percent of running load torque. Page 15 (HFDD) also states initial start factor, which is the nominal torque applied at the inception of acceleration, expressed as a percent of running load torque. The low initial start factor (HFDD) assures an extra soft empty belt start on low inertia conveyors, yet is adequate to overcome the breakaway torque of the conveyor. For general duty (other than belt conveyors), select from pages 16 thru 19. Start Factor is equivalent to the initial start factor mentioned in the paragraph above. For these general duty applications, the initial start factor ensures breakaway of the driven machinery. 3. Refer to the Quick Selection tables (pages 14 thru 19). For belt conveyors, select HFN or HFD from page 14. For extra soft empty belt starts on low inertia belt conveyors, consider HFDD selections on page 15. For general duty (other than belt conveyors), select HFD or HFN/HFR from pages 16 thru 19. Note the percent slip and fill angle. 4. Select one of the Mounting Arrangements (gear coupling, disc coupling, etc.) from page For coupling size, basic type, and mounting arrangement selected, see Availability Table, page 13. This table indicates whether the selection is available and, if so, the allowable speed. 6. If the initial basic type and mounting arrangement are not available or there is insufficient allowable speed, consider an alternative basic type/mounting arrangement. 7. Check bore capacity of the coupling selected from the dimension tables, pages 20 thru 29. Selection Example: 1. Belt Conveyor: Fluid coupling connects a motor to the input shaft of a gear drive. Motor is NEMA B, rated 100 hp at 1775 rpm. Running load = 98 hp. Motor shaft 2.875", gear drive input shaft 2.250". 2. With the Start Factor 120% to 140%, select from pages 14 and 15 as appropriate (selections for belt conveyors). 3. Use HFD selections for belt conveyors, page 14. For 98 hp running load, select 370HFD, 4.1% slip, fill angle 63 degrees. 4. Select 370HFD20 (gear coupling mount) from page 12 economical and includes drop-in/drop-out servicing. 5. From the Availability Table, page 13, 370HFD20 is available, allowable speed is 1800 rpm, exceeds the requirement of 1775 rpm. 6. Alternative basic type/mounting arrangements are listed on page From page 21 dimensions, max bore is 2.875", which is adequate. Start Factor Table Applications Start Factor Select From Belt Conveyors 120% to 140% pages General Duty Fans 140% pages Mixers 170% to 200% pages Crushers 250% pages Armored Face Conveyors Refer to the Factory Refer to the Factory ( ) 11
12 Mounting Arrangements Gear Mount Type HF20 (Exposed Bolt) Most economical Drop-in/drop-out servicing (no need to move connected equipment) Available s Readily shipped from stock components Pages Pages Steelflex/Hollow Shaft Mount Type HF31 (Setscrew Retention) Type HF32 (Keeper Plate Retention) For limited shaft gaps/steelflex grid coupling at driving end Hollow shaft bored to the order Type HF31/available s /secured to driven shaft with 2 setscrews/ allow clearance for setscrew wrench Type HF32/available s /secured to driven shaft with keeper plate and retention fastener/drill and tap driven shaft end for retention fastener Excellent performance at high power and high rpm Disc Mount Type HF25 Non-lubricated, low maintenance, long life Drop-in/drop-out servicing (no need to move connected equipment) Available s Excellent performance at high power and high rpm Page 24 Tschan/Hollow Shaft Mount Type HF132 For minimum shaft gaps/tschan elastomeric coupling at driving end Non-lubricated, low maintenance Hollow shaft bored to the order Available s /secured to driven shaft with keeper plate and retention fastener/drill-and-tap-driven shaft end for retention fastener Excellent performance at high power and high rpm Page 25 Pages Sheave/Hollow Shaft Mount Type HF41 For V-Belt connections Mounted on motor shaft s /QD sheave by purchaser/standard hollow shaft collet with draw bolt by Factory 1420/special sheave by Factory/standard hollow shaft collet with draw bolt by Factory s /special sheave by Factory/hollow shaft bored to the order/ secured to motor shaft with keeper plate and retention fastener/drill-and-tap motor shaft end for retention fastener Follow manufacturer s recommendations when tensioning V-Belts 12 ( )
13 Fluid Identification 1420 HFD 20 SIZE BASIC TYPE HFN = Non Delay Fill HFD = Delay Fill HFDD = Extended Delay Fill HFR = Inactive Delay Fill HFNR = Reverse Mounted HFN (requires internal modifications) HFDR = Reverse Mounted HFD (requires internal modifications) HFRR = Reverse Mounted HFR (requires internal modifications) MOUNTING ARRANGEMENTS With Falk G Gear : 10: Shrouded bolt design 20: Exposed bolt design With Falk FD Disc : 25: With Falk T Steelflex : 31: Thru bore with setscrew 31-1: Max bore with setscrew 32: Thru bore with keeper plate 32-1: Max bore with keeper plate With Tschan : 132: Thru bore with keeper plate 132-1: Maximum bore with keeper plate With Sheave: 41: Motor mounted with sheave at output 42: Driven shaft mounted with sheave at input (requires internal modifications) Availability Table (by Basic Type & Mounting Arrangement) (An Allowable Speed indicates that the fluid coupling Basic Type and Mounting Arrangement is available for the given size) Basic Type Mounting Arrangement & Allowable Speed (rpm) Gear HFN Gear HFN Gear HFD Gear HFDD Gear HFR Steelflex HFN Steelflex HFD 31, Steelflex HFR 31, Steelflex HFN 32, Steelflex HFD 32, Steelflex HFR 32, Disc HFN Disc HFD Disc HFDD Disc HFR Tschan HFD 132, Tschan HFDD 132, Tschan HFR 132, Sheave HFN Sheave HFD ( ) 13
14 Quick Selection HFN & HFD for Belt Conveyors ➀ Quick Selection Table RPM Input Speed ➀ ➁ ➂ ➃ ➄ Load HP Start Factor 140% for Belt Conveyors ➂ 1775 RPM 1450 RPM 1170 RPM 970 RPM 870 RPM HFN & HFD HFN & HFD HFN & HFD HFN & HFD HFN & HFD ➁ ➁ ➁ ➁ ➁ ➁ ➁ ➁ ➁ ➁ ➁ ➁ ➁ ➄ ➄ ➄ ➁ ➁ ➄ ➄ ➄ ➁ ➄ ➄ ➄ ➁ ➄ ➄ ➄ ➄ ➄ ➄ ➁ ➄ ➄ ➄ ➄ ➄ ➄ ➁ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➃ ➄ ➄ ➄ ➃ ➃ HFN Selections above the BOLD line are HFN. Selections below the BOLD line are HFD. For these 1584HFD and 1660HFD selections, see page 13 for Availability Table (by Basic Type and Mounting Arrangement). Choose a mounting arrangement with adequate allowable speed for the application. Start Factor 140% for belt conveyors is the average starting torque exerted by the fluid coupling during load acceleration, expressed as a percent of running load torque. Based on 150% Start Factor. Refer to the Factory. HFD 14 ( ) NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request.
15 Quick Selection HFDD for Belt Conveyors Quick Selection Table RPM Input Speed ➀ ➁ ➂ ➃ Load HP Start Factor 120% for Belt Conveyors ➁ 1775 RPM 1450 RPM 1170 RPM Initial Start Factor ➂ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➃ ➃ ➀ ➃ ➃ ➀ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ Initial Start Factor ➂ HFDD For these 1584HFDD and 1660HFDD selections, see page 13 for Availability Table (by Basic Type and Mounting Arrangement). Choose a mounting arrangement with adequate allowable speed for the application. Start Factor 120% for belt conveyors is the average starting torque exerted by the fluid coupling during load acceleration, expressed as a percent of running load torque. Initial start factor for HFDD selections is the nominal torque applied at the inception of acceleration, expressed as a percent of running load torque. The low initial start factor assures an extra soft empty belt start on low inertia conveyors, yet is adequate to overcome the breakaway torque of the conveyor. Refer to the Factory. Initial Start Factor ➂ NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request. ( ) 15
16 Quick Selection General Duty (Other than Belt Conveyors) Quick Selection Table 1775 RPM Input Speed Load HP General Duty Start Factor ➁ 140% 170% 200% 250% HFD HFN/HFR ➂ HFD HFN/HFR ➂ HFD HFN/HFR ➂ HFD HFN/HFR ➂ 16 ( ) NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➃ 1584 ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➃ 1584 ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ 1660 ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➁ ➂ ➃ For these 1584HFD and 1660HFD selections, see page 13 for Availability Table (by Basic Type and Mounting Arrangement). Choose a mounting arrangement with adequate allowable speed for the application. Start Factor for general duty (other than belt conveyors) is the nominal torque applied at the inception of acceleration, expressed as a percent of running load torque. s 185/235/270/320/2870 are HFN. s 370/1420/1480 are HFN or HFR, depending on mounting arrangement. s 1584/1660/2760 are HFR. 175% Start Factor.
17 Quick Selection General Duty (Other than Belt Conveyors) Quick Selection Table 1450 RPM Input Speed Load HP General Duty Start Factor ➁ 140% 170% 200% 250% HFD HFN/HFR ➂ HFD HFN/HFR ➂ HFD HFN/HFR ➂ HFD HFN/HFR ➂ ➃ ➃ ➄ ➄ ➀ ➀ ➀ ➄ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➅ 1660 ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➆ ➀ ➁ ➂ s 185/235/270/320/2870 are HFN. s 370/1420/1480 are HFN or HFR, depending on mounting arrangement. s 1584/1660/2760 are HFR. ➃ 145% Start Factor. ➄ 155% Start Factor. ➅ 175% Start Factor. ➆ Refer to the Factory. NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request. ( ) 17 For these 1584HFD and 1660HFD selections, see page 13 for Availability Table (by Basic Type and Mounting Arrangement). Choose a mounting arrangement with adequate allowable speed for the application. Start Factor for general duty (other than belt conveyors) is the nominal torque applied at the inception of acceleration, expressed as a percent of running load torque.
18 Quick Selection General Duty (Other than Belt Conveyors) Quick Selection Table 1170 RPM Input Speed Load HP General Duty Start Factor ➀ 140% 170% 200% 250% HFD HFN/HFR ➁ HFD HFN/HFR ➁ HFD HFN/HFR ➁ HFD HFN/HFR ➁ 18 ( ) NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request ➂ ➂ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➃ ➀ ➁ ➂ ➃ Start Factor for general duty (other than belt conveyors) is the nominal torque applied at the inception of acceleration, expressed as a percent of running load torque. s 185/235/270/320/2870 are HFN. s 370/1420/1480 are HFN or HFR, depending on mounting arrangement. s 1584/1660/2760 are HFR. 150% Start Factor. Refer to the Factory.
19 Quick Selection General Duty (Other than Belt Conveyors) Quick Selection Table 870 RPM Input Speed Load HP General Duty Start Factor ➀ 140% 170% 200% 250% HFD HFN/HFR ➁ HFD HFN/HFR ➁ HFD HFN/HFR ➁ HFD HFN/HFR ➁ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➂ ➀ ➁ ➂ Start Factor for general duty (other than belt conveyors) is the nominal torque applied at the inception of acceleration, expressed as a percent of running load torque. s 185/235/270/320/2870 are HFN. s 370/1420/1480 are HFN or HFR, depending on mounting arrangement. s 1584/1660/2760 are HFR. Refer to the Factory. NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request. ( ) 19
20 s and Dimensions HFN20 Gear Mount (Non Delay Fill) Flex half of Type G gear coupling at input and output, with gap discs, for horizontal mounting. Type G gear coupling hubs are furnished interference fit, no setscrew, unless specified otherwise. The fluid coupling drops in or out when gear coupling sleeves are unbolted and retracted. Availability by & Type Type Description HFN20 Non Delay Fill X X X X X X X GASKET FILLER/FUSIBLE PLUG 392 F (200 C) FLUID COUPLING J H MINIMUM CLEARANCE REQUIRED FOR ALIGNMENT GASKET DRIVING END A F D C BE BETWEEN ENDS M C AA DRIVEN END FLEX HUB ELASTOMER GAP DISC ELASTOMER GAP DISC LUBRICATE THRU SLEEVE INPUT ADAPTER OUTPUT ADAPTER DRAIN/FUSIBLE PLUG (FILL PLUG SIZE 320) 284 F (140 C) SIZE 185HFN10-370HFN10 (SHROUDED BOLTS) FURNISHED ONLY WHEN SPECIFIED ON THE ORDER Dimensions (in) Cplg ➀ Cplg Weight No Bore & w/o Fluid (lb) HFN20 Allow Speed RPM A C D F H J M AA BE Maximum Bore ➁ Shaft Type G20 Square Rect Key Key ➂ Lube Wt per Gear Cplg Half (lb) Input WR 2 (lb-in 2 ) ➃ 185HF ➄ HF HF HF HF , HF , HF ,630 1,504 1,505 Output Max Fill ➀ Fluid couplings are offered for horizontal mounting as shown. Consult the Factory for other mounting arrangements. Dimensions are for reference only and subject to change without notice unless certified. ➁ Type G couplings are furnished with an average interference fit of " per inch of shaft diameter, without setscrew, unless otherwise specified. Maximum bore capacity is reduced when interference fit with a setscrew over the keyway is specified. Refer to publication for allowable bores. ➂ Replace square shaft key with standard rectangular key for use with these bores. NOTE: Check key stresses. ➃ Equivalent mass moment values shown apply only to the fluid coupling with adapters (gear coupling halves not included). Refer to page 29 for fluid WR 2 multipliers for other than maximum fill. ➄ For 185HFN, the 1010G flex half at the driving end mounts directly to the fluid coupling. The input adapter, and driving and driven end gap discs, are not required. 20 ( ) NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request.
21 HF20 Gear Mount (with Delay Fill Chamber) Flex half of Type G20 (exposed bolt) gear coupling at input and output, with gap discs, for horizontal mounting. Type G gear coupling hubs are furnished interference fit, no setscrew, unless specified otherwise. The fluid coupling drops in or out when gear coupling sleeves are unbolted and retracted. Availability by & Type Type Description HFD20 Delay Fill X X X X X HFDD20 Extended Delay Fill X X X X HFR20 Inactive Delay Fill X X FILLER/FUSIBLE PLUG 392 F (200 C) FLUID COUPLING J H MINIMUM CLEARANCE REQUIRED FOR ALIGNMENT GASKET GASKET DRIVING END A M C BETWEEN C BE F D ENDS AA FLEX HUB DRIVEN END ELASTOMER GAP DISC ELASTOMER GAP DISC LUBRICATE THRU SLEEVE INPUT ADAPTER OUTPUT ADAPTER SIZES 1420 & LARGER TYPES HFD & HFDD DRAIN/FUSIBLE PLUG 284 F (140 C) METERING ORIFICE, (3) EQUALLY SPACED SEE PAGE 6 FOR DETAILS Dimensions (in) Cplg Weight No Bore & Maximum Bore ➁ Lube WR 2 (lb-in 2 ) ➂ Cplg w/o Fluid Allow BE Wt per (lb) Gear speed A C D F H J M AA Cplg ➀ RPM Shaft Type Half HFD G20 Input Max Fill (lb) HFR HFDD Output HFD HFR HFDD Square Rect ➃ HFD Key Key HFR HFDD HFD HFR HFDD 370HF 156 N/A N/A ,910 N/A N/A N/A 1420HF ,080 3, N/A HF ,700 6,030 1,550 1,980 N/A 1, HF ,150 13,000 3,570 4,955 3,844 5, HF ,900 24,400 6,210 9,225 8,167 9,570 ➀ Fluid couplings are offered for horizontal mounting as shown. Consult the Factory for other mounting arrangements. Dimensions are for reference only, and are subject to change without notice unless certified. ➁ Type G couplings are furnished with an average interference fit of " per inch of shaft diameter, without setscrew, unless otherwise specified. Maximum bore capacity is reduced when interference fit with a setscrew over the keyway is specified. Refer to publication for allowable bores. ➂ Equivalent mass moment values shown apply only to the fluid coupling with adapters (gear coupling halves not included). Refer to page 29 for fluid WR 2 multipliers for other than maximum fill. ➃ To use these maximum bores, a customer-furnished rectangular key must replace the standard square key that was supplied with the shaft. NOTE: Check key stresses. NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request. ( ) 21
22 HF31, 31-1 Steelflex/Hollow Shaft Mount Steelflex Type T10 coupling input, hollow shaft output, for horizontal mounting. Hollow shaft is bored to the order, modified clearance fit, with (2) setscrews, one over keyway, one at 90 degrees to keyway. Types HF31, 31-1 diminish the gap required between connected shafts. Type HF31-1 has greater max bore in the hollow shaft, but requires more shaft gap than HF31. Availability by & Type Type Description HFN31 Non Delay Fill X HFD31, 31-1 Delay Fill X X X HFR31, 31-1 Inactive Delay Fill X X X TYPE 31 TYPE 31-1 COVER HUB GRID S USABLE NA LENGTH GAP FILLER/FUSIBLE PLUG 392 F (200 C) STUB KEY FLUID COUPLING EA SA AA MAXIMUM ENGAGEMENT Notice HF31, 31-1: Allow clearance for setscrew wrench. MAXIMUM ENGAGEMENT A D C T10 T CA SE MIN ENGAGEMENT QA SE MIN ENGAGEMENT DRIVING END LUBE PLUG J HOLLOW DRIVEN END BA SIZES 1420 & LARGER TYPES HFD & HFDD DRAIN/FUSIBLE PLUG (FILL PLUG SIZE 320) 284 F (140 C) METERING ORIFICE, (3) EQUALLY SPACED Dimensions (in) Cplg ➀ Cplg Weight No Bore & w/o Fluid (lb) HFN HFD HFR Allow Speed RPM A C D J S AA HFN BA HFD HFR CA DA EA IA ➃ Fastener Types 32 & 32-1 NA Type 31-1 QA Type 32-1 SA ➁ SE ➄ (Min) YA ➃ 320HF 89 N/A N/A /8-11 UNC 2.75 N/A HF N/A N/A /4-10 UNC HF N/A N/A /8-9 UNC HF N/A N/A N/A /8-9 UNC HF N/A N/A N/A UNC 5.49 N/A 7.50 N/A HF N/A N/A N/A /4-7 UNC 6.33 N/A 9.00 N/A HF N/A ➂ N/A N/A /4-7 UNC 7.69 N/A N/A ➀ Fluid couplings are offered for horizontal mounting as shown. Refer to the Factory for other mounting arrangements. Dimensions are for reference only and are subject to change without notice unless certified. ➁ Setscrew sizes: s 320HF thru 1420HF are X HF is X ➂ Special aluminum components. ➃ Dimensions on page 23. ➄ SE minimum listed is for Types 31 and 31-1 ONLY. For Types 32 and 32-1, the SE minimum formula is 1.5 times driven shaft diameter. 22 ( ) NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request.
23 HF32, 32-1 Steelflex/Hollow Shaft Mount Steelflex Type T10 coupling input, hollow shaft output, for horizontal mounting. Hollow shaft is secured to driven shaft by axial retention fastener. Hollow shaft is bored to the order and includes modified transitional fit, no setscrew. Driven shaft end must be drilled and tapped for retention fastener, and fluid coupling includes Factory-furnished spacer (spacer machined to length by the Factory, based on actual shaft engagement dimension provided by customer). Types HF32, 32-1 diminish the gap required between connected shafts. Type HF32-1 has greater max bore in the hollow shaft, but requires more shaft gap than HF32. Availability by & Type Type Description HFN32, 32-1 Non Delay Fill X HFD32, 32-1 Delay Fill X X X X X X HFR32, 32-1 Inactive Delay Fill X X X X X X TYPE 32 TYPE 32-1 FILLER/FUSIBLE PLUG 392 F (200 C) FLUID COUPLING COVER HUB GRID S NA USABLE LENGTH GAP STUB KEY KEEPER PLATE EA AA MAXIMUM ENGAGEMENT A D C T10 T YA CA DA SE MIN ENGAGEMENT SE MIN ENGAGEMENT DRIVING END LUBE PLUG J IA FASTENER SPACER HOLLOW QA DRIVEN END MAXIMUM ENGAGEMENT BA SIZES 1420 & LARGER TYPES HFD & HFDD DRAIN/FUSIBLE PLUG (FILL PLUG SIZE 320) 284 F (140 C) METERING ORIFICE, (3) EQUALLY SPACED Dimensions (in) Cplg ➀ T Stub Shaft Maximum Bore WR 2 (lb-in 2 ) ➄ Shaft ➁ Hollow Shaft ➃ Max Fill Type T10 Type 31 ➃ Type 31-1 ➃ Type 32 ➃ Type 32-1 ➃ Key Input Output GAP HFN HFR HFD Sq Rect Sq Rect Sq Rect Sq Rect Sq Rect Key Key ➂ Key Key ➂ Key Key ➂ Key Key ➂ Key Key ➂ 320HF /2 x 1/2 x 2-1/ N/A N/A N/A N/A 370HF /8 x 5/8 x 2-3/ , HF /4 x 3/4 x , HF /8 x 7/8 x 3-3/ ,620 1,260 1,504 1, HF x 1 x N/A N/A N/A N/A ,100 2,900 3,844 4, HF x 1 x 4-1/ N/A N/A N/A N/A ,830 5,080 8,167 9, HF /4 x 1-1/4 x 5-1/ N/A N/A N/A N/A N/A ,750 9,360 14,660 16,230 ➀ Fluid couplings are offered for horizontal mounting as shown. Refer to the Factory for other mounting arrangements. Dimensions are for reference only and are subject to change without notice unless certified. ➁ Unless otherwise specified, s 1060T10 thru 1090T10 will be furnished for clearance fit with a setscrew over the keyway, and s 1100T10 and larger will be furnished for interference fit without setscrew. Maximum bore capacities of Type T10 coupling hubs are reduced when interference fit with a setscrew over the keyway is specified. Refer to publication for allowable bores. ➂ To utilize these maximum bores, a customer-furnished rectangular key must replace the standard square key that was supplied with the shaft. NOTE: Check key stresses. ➃ Types 31 & 31-1 hollow shafts are furnished for a modified clearance fit with one setscrew over the keyway and one setscrew at 90 to the keyway. Types 32 & 32-1 hollow shafts are furnished with modified transitional fit, no setscrew. ➄ Equivalent mass moment values shown apply only to the fluid coupling (without bore), with stub shaft (flexible coupling not included). Refer to page 29 for fluid WR 2 multipliers for other than maximum fill. NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request. ( ) 23
24 HF25 Disc Mount Type FD disc coupling mount with discpack at input and output, for horizontal mounting. A-Hubs are furnished interference fit, no setscrew, unless specified otherwise. The fluid coupling drops in or out, in conjunction with discpack/adapter assemblies. Availability by & Type Type Description HFN25 Non Delay Fill X HFD25 Delay Fill X X X X X X X HFDD25 Extended Delay Fill X X X X X X HFR25 Inactive Delay Fill X X X X X X FILLER/FUSIBLE PLUG 392 F (200 C) FLUID COUPLING INPUT ADAPTERS OUTPUT ADAPTERS A HUB A HUB K C BE BETWEEN ENDS C D F H A AA DRIVING END DRIVEN END SIZES 1420 & LARGER TYPES HFD & HFDD DRAIN/FUSIBLE PLUG 284 F (140 C) METERING ORIFICE, (3) EQUALLY SPACED SEE PAGE 6 FOR DETAILS Dimensions (in) Cplg Weight No Bore & Maximum Bore ➁ WR 2 (lb-in 2 ) ➂ Cplg w/o Fluid (lb) Allow BE Speed A C D F H K AA Shaft ➀ RPM HFD Type FD Input Max Fill HFR HFDD Output HFD HFR HFDD Sq. Key HFD HFR HFDD HFD HFR HFDD 370HF 184 N/A N/A 190FD06A ,870 N/A N/A 1420HF FD06A ,850 3, HF FD06A ,214 5,545 1,864 1,980 1,504 1, HF FD06A ,200 12,050 3,620 4,955 3,844 5, HF FD06A ,815 22,315 7,290 9,225 8,167 9, HF FD06A ➃ 38,520 41,321 14,275 16,230 14,660 15, HF FD08A Refer to Factory ➀ Fluid couplings are offered for horizontal mounting as shown. Refer to the Factory for other mounting arrangements. Dimensions are for reference only and are subject to change without notice unless certified. ➁ Type FD Disc s are furnished with an average interference fit of " per inch of shaft diameter, without setscrew, unless otherwise specified. Maximum bore capacity is reduced when interference fit with a setscrew over the keyway is specified. Refer to publication for allowable bores. ➂ Equivalent mass moment values shown apply only to fluid coupling (without bore). Refer to page 29 for fluid WR 2 multipliers for other than maximum fill. ➃ Maximum bore is for hub with keyway for rectangular key. 24 ( ) NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request.
25 HF132 & Tschan/Hollow Shaft Mount Tschan coupling input, hollow shaft output, for horizontal mounting. Hollow shaft is secured to driven shaft by axial retention fastener. Hollow shaft is bored to the order and includes modified transitional fit, no setscrew. Driven shaft end must be drilled and tapped for retention fastener, and fluid coupling includes Factory-furnished spacer (spacer machined to length by the Factory, based on actual shaft engagement dimension provided by customer). Types HF132, permit smallest possible gap between connected shafts. Type HF132-1 has greater max bore in the hollow shaft, but requires more shaft gap than HF132. Availability by & Type Type Description HFD132, Delay Fill X X X X X X HFDD132, Extended Delay Fill X X X X X HFR132, Inactive Delay Fill X X X X X X TYPE HF132 TYPE HF132-1 SIZES 1420 & LARGER TYPES HFD & HFDD FILLER/FUSIBLE PLUG 392 F (200 C) FLUID COUPLING TSCHAN COUPLING B METERING ORIFICE, (3) EQUALLY SPACED SEE PAGE 6 FOR DETAILS KEEPER PLATE MAXIMUM ENGAGE- MENT AA DRIVEN END DRIVING END A D EX C YA SPACER CA DA SE MIN ENGAGE- MENT HOLLOW QA SE MIN ENGAGEMENT IA FASTENER MAXIMUM ENGAGEMENT BA DRAIN/FUSIBLE PLUG 284 F (140 C) Dimensions (in) Cplg ➀ Cplg Only, Weight No Bore & w/o Fluid (lb) HFD & HFR HFDD Allow Speed RPM A B C D AA HFD & HFR BA HFDD CA DA IA Fastener 370HF 112 N/A ➁ N/A /4-10 UNC 0.13 N/A HF /8-9 UNC HF /8-9 UNC HF UNC HF ➁ /4-7 UNC HF ➆ ➁ /4-7 UNC HFD & HFR EX HFDD SE (Min) YA QA Cplg ➀ Maximum Bore WR 2 (lb-in 2 ) ➅ Tschan ➂ Hollow Shaft (transitional fit, no ss) Input Max Fill Type 132 Type Output Square Key HFD & HFR HFDD HFR HFD HFDD Square Key Square Key Rectangular Key ➄ 370HF ,811 N/A N/A 1420HF ➃ ,802 3, HF ,228 5,608 1,260 1,504 1,980 1, HF ,448 12,293 2,903 3,844 4,955 5, HF ,186 23,990 5,076 8,167 9,225 9, HF N/A ,614 39,938 9,252 14,660 16,230 15,240 ➀ Fluid couplings are offered for horizontal mounting as shown. Refer to the Factory for other mounting arrangements. Dimensions are for reference only and subject to change without notice unless certified. ➁ Non-standard shortened Tschan hub length. ➂ Tschan coupling hubs are furnished with an average interference fit of " per inch of shaft diameter, unless specified otherwise. ➃ 1420HF is available with a 2.88" bore and a 0.750" x 0.125" keyway. Rexnord will furnish a flat key 0.750" x 0.500" x 3.5". ➄ To use these maximum bores, a customer-furnished rectangular key must replace the standard square key that was supplied with the shaft. NOTE: Check key stresses. ➅ Equivalent mass moment values shown apply only to the fluid coupling (without bore). Refer to page 29 for fluid WR 2 multipliers for other than maximum fill. ➆ Special aluminum components. NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request. ( ) 25
26 HF41 Sheave/Hollow Shaft Mount Hollow shaft input, QD sheave output, for horizontal mounting. For all sizes below, the Factory furnishes a specially manufactured QD Adapter (in lieu of QD bushing) to accommodate the QD sheave supplied by purchaser. All sizes below are secured to the motor shaft by a collet/collet draw bolt. Availability by & Type Type Description HFN41 Non Delay Fill X X X X X HFD41 Delay Fill X FILLER/FUSIBLE PLUG 392 F (200 C) K N L TYPE HFN SHEAVE (BY PURCHASER) WRENCH FLATS COLLET DRAW BOLT AA SE ENGAGEMENT COLLET TYPE HFD (See Page 26 for Standard Collets) D G E BA DRAIN/FUSIBLE PLUG (FILL PLUG SIZE 320) 284 F (140 C) Dimensions (in) Cplg ➀ Cplg Weight No Bore & w/o Sheave, Fluid (lb) HFN HFD Allowable Speed RPM Sheave Adapter QD ➁ D E ➂ G N AA BA SE (Min) SE (Max) 185HF 22 N/A 1800 SDS N/A HF 38 N/A 1800 SK N/A HF 50 N/A 1800 SF N/A HF 81 N/A 1800 E N/A HF E See page 27 Cplg Collet Min Bore ➃ (in) Square Key Collet Max Bore (in) ➃ Rectangular Key ➄ Input Type HFN Output Max Fill WR 2 (lb-in 2 ) ➅ Input Type HFD 185HF N/A N/A N/A 235HF N/A N/A N/A 270HF N/A N/A N/A 320HF N/A N/A N/A 370HF , , Output Max Fill ➀ Fluid couplings are offered for horizontal mounting as shown. Refer to the Factory for other mounting arrangements. Dimensions are for reference only and are subject to change without notice unless certified. Rexnord furnishes a specially manufactured QD Adapter (in lieu of QD bushing) to accommodate the QD sheave supplied by purchaser. ➁ Rexnord furnishes a specially manufactured QD Adapter (in lieu of QD bushing) to accommodate the QD sheave supplied by purchaser. ➂ For Dimensions K and L, refer to sheave tables on page 27. Dimensions E and L for s 185 thru 370 may vary up to ±.12 inches. For Dimension L, negative value represents dimension to the left of collet face. ➃ Minimum bore is the smallest bore to which the collet will be bored. Standard collets (see page 27). Refer to the Factory for non-standard collets. ➄ To use these maximum bores, a customer-furnished rectangular key must replace the standard square key that was supplied with the shaft. NOTE: Check key stresses. ➅ Equivalent mass moment values shown apply only to the fluid coupling (without bore), adapter and sheave. Refer to page 29, Engineering Data, for fluid WR 2 multipliers for other than maximum fill. 26 ( ) NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request.
27 HF41 Sheave/Hollow Shaft Mount Classical Sheaves (A, B, C) Dimensions (in) Cplg ➀ 185HF 235HF 270HF 320HF 370HF K L ➁ Pitch Diameter Grooves Classical Sheaves A , A B ➃ B ➃ B ➃ B B B , A A A B ➃ B ➃ B ➃ B ➃ , B ➃ , B ➃ B B B B , B , B B ➃ B ➃ B ➃ B ➃ B ➃ B ➃ B ➃ B B B B B B B C C B ➃ B ➃ B ➃ B ➃ B ➃ B ➃ B B B B B B C , C C C C C B ➃ B ➃ B ➃ B ➃ B ➃ B ➃ B B B B B B C , C C C C Sheave Adapter (QD) ➂ SDS SK SF E E Narrow Sheaves (3V, 5V) Dimensions (in) Cplg ➀ 185HF 235HF 270HF 320HF 370HF K L ➁ Outside Diameter Grooves Narrow Sheaves V V V V V , V V V V V V V V V V V V , V , V , V , V V V V V , V V V V V V V , V V V V V , V V V V V V V , V V V Sheave Adapter (QD) ➂ Standard Collets Dimensions (in) (Refer to Factory for Special Collets) 185HF 235HF 270HF 320HF 370HF SDR Collet Part Number Motor Shaft SE (Max) ➄ ➄ ➄ ➄ ➄ 6.40 ➀ ➁ ➂ See page 26 for these footnotes. ➃ A belt in Type B sheave. ➄ Maximum bore collet requires that standard square shaft key be replaced with customer-furnished rectangular key. Service Manual , Table 2, provides rectangular key sizes. NOTE: Check key stresses. SK SF E E NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request. ( ) 27
28 HF41 Sheave/Hollow Shaft Mount Hollow shaft input, sheave output, for horizontal mounting. For all sizes below, a specially manufactured sheave is supplied by the Factory. 1420HF is secured to the motor shaft by a collet/collet draw bolt. s 1480HF & 1584HF are secured to the motor shaft by an axial retention fastener, the hollow shaft is bored to the order and includes modified transitional fit, no setscrew, motor shaft end must be drilled and tapped for retention fastener, and coupling includes Factory-furnished spacer (spacer to length by the Factory, based on actual shaft engagement dimension provided by customer). Availability by & Type Type Description HFN41 Non Delay Fill X X X HFD41 Delay Fill X X X N FILLER/FUSIBLE PLUG 392 F (200 C) K N FILLER/FUSIBLE PLUG 392 F (200 C) IA FASTENER TYPE HFN WRENCH FL ATS L SHEAVE (BY FALK) TYPE HFN SHEAVE (BY FALK) COLLET DRAW BOLT SE ENGAGEMENT AA COLLET (PAGE 32) QA SE MAXIMUM ENGAGEMENT MINIMUM ENGAGEMENT AA D TYPE HFD G TYPE HFD G BA DRAIN/FUSIBLE PLUG 284 F (140 C) BA DRAIN/FUSIBLE PLUG 284 F (140 C) & 1584 Predesigned Sheaves for 1420HF41 Part Number Description " OD, 5V-5 groove " OD, 5V-8 groove " OD, 5V-5 groove " OD, 5V-10 groove Dimensions (in) Cplg ➀ Cplg Weight No Bore & w/o Sheave, Fluid (lb) HFN HFD Allowable Speed RPM D G N AA BA IA Fastener QA (Max Shaft Engagement) SE ➂ (Min) 1420HF ➁ 1480HF /8-9 UNC HF UNC Cplg Min Bore Square Key Max Bore Rectangular Key ➄ Type HFN WR 2 (lb-in 2 ) ➅ 28 ( ) NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request. Input Output Max Fill Input Type HFD 1420HF ➃ , , HF ,230 4,440 1,504 1,230 4,615 1, HF ,840 9,910 3,844 2,840 10,080 4,955 ➀ Fluid couplings are offered for horizontal mounting as shown. Refer to the Factory for other mounting arrangements. Dimensions are for reference only, and are subject to change without notice unless certified. ➁ 1420HF, see page 29 for dimensions K, L, and SE (Max). ➂ The preferred engagement between the driving shaft and the hollow bore is twice the diameter of the driving shaft. ➃ Minimum bore is the smallest bore to which the collet will be bored. Standard collets (see page 29). Refer to the Factory for non-standard collets. ➄ To use these maximum bores, a customer-furnished rectangular key must replace the standard square key that was supplied with the shaft. NOTE: Check key stresses. ➅ Equivalent mass moment values shown apply only to the fluid coupling (without bore) and sheave. Refer to page 29, Engineering Data, for fluid WR 2 multipliers for other than maximum fill. Output Max Fill
29 Technical Data HF41 Sheave/Hollow Shaft Mount HF41 Sheave & Collet Data (s 1420 thru 1584HF) Classical Sheaves (B, C, D) Dimensions (in) Cplg ➀ Pitch Diameter Grooves Classical Sheaves B 1480HF C C D 1584HF 11.0 & B B C C 12.0 & D D Narrow Sheaves (3V, 5V, 8V) Dimensions (in) Cplg ➀ K L ➁ 1420HF 1480HF 1584HF Outside Diameter Grooves Narrow Sheaves & V V V 8.0 & V 10.6 & V V V V V V V V Standard Collets ➂ Dimensions (in) (Refer to Factory for Special Collets) Cplg Collet Part Number Motor Shaft SE (Max) HF ➃ 8.44 ➀ Dimensions are for reference only, and are subject to change without notice unless certified. ➁ 1420 Dimension L, negative value represents dimension to the left of collet face. ➂ s 1480HF & 1584HF do not utilize a collet. ➃ Maximum bore collet requires that standard square shaft key be replaced with customer-furnished rectangular key. Service Manual , Table 2, provides rectangular key sizes. NOTE: Check key stresses. Engineering Data Shaft Diameters and Ratings for NEMA 60 Hertz Motors T Frames Frame Shaft Dia (in) Drip 1800 Proof 1 1-1/ / RPM TEFC 1 1-1/ / RPM 900 RPM Drip Proof & TEFC Drip Proof & TEFC 3/ / / /2 3/ / / Shaft Diameters and Ratings for NEMA 60 Hertz Motors TS Frames Frame Shaft Dia (in) Drip Proof TEFC RPM 1200 RPM 900 RPM Drip Proof & TEFC Drip Proof & TEFC Fluid WR 2 Multiplier for Other Than Maximum Fill HFN HFD HFDD ➀ ➀ Maximum fluid fill for Type HFDD is 60. Recommended Keys for Bores with One Key Dimensions (in) Shaft Diameters Shaft Diameters Key Over Thru Over Thru Key x x x x x x x x x x x x x x NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request. ( ) 29
30 Fluid Recommended Fluids ➀ HIGH LEVEL OF FILL LOW LEVEL OF FILL 100 Fluid couplings are shipped without fluid. Fluid is added during installation. The installer adds fluid, obtained locally, and that meets Recommended Fluids specifications listed on this page. When application data (horsepower, rpm, start factor) is provided, the fluid coupling will include an orange sticker with fill angle (degrees), and approximate fill quantity (fluid ounces). If no orange sticker is present, a fill angle may be obtained from the Quick Selection tables in this catalog (pages 14-19). Using fill angle as a starting point, approximate fill quantity (fluid ounces) may be obtained from the table below. Fluid couplings include an angle finder (P/N ) and installation instructions. Remove the fill plug, place the angle finder on the flat boss at the fill plug location, and rotate the coupling to the specified fill angle (degrees from vertical). With the coupling in this position, add fluid until it reaches the lip of the fill hole. As shown above, a low fill angle (example is 50 ) corresponds to a high level of fill. A high fill angle (example is 100 ) corresponds to a low level of fill. The level of fill in the coupling determines the start factor, percent slip, starting torque, stall torque,... essentially all performance characteristics of the coupling. After installation and operation, fine-tuning of the fill level may be necessary, based on load readings or other site variables. In general, increasing the fill level (decreasing the fill angle) increases start factor/start torque/stall torque, shortens time required to accelerate the load to operating speed, and reduces percent slip. Reducing the fill level (increasing the fill angle) decreases start factor/start torque/stall torque, increases time required to accelerate the load to operating speed, and increases percent slip. Convert Fluid Ounces to Weight (lb) There are 128 Fluid Ounces per Gallon Weight (lb) = Fluid oz x x specific gravity of the fluid Example: 70 degree fill angle (See table below) Weight = 413 fluid oz x x 0.87 = 23.3 lb of fluid Approximate Fill Quantity (Fluid Ounces) (Degrees) from Vertical ISO Viscosity Grade, Petroleum Oils (R & O) ISO Viscosity Grade, Synthetic Oils Viscosity at 104 F(40 C) 46 cst (215 SSU) Viscosity Index Equal to or greater than 95. Pour Point Must be 5 F (3 C) lower than minimum starting temperature. Flash Point 400 F (204 C) when using 140 C and/or 180 C fusible plugs. Flash Point 425 F (218 C) when using 200 C fusible plugs at both fill and drain holes. Specific Gravity 0.87 Antioxidant and Anti-foaming Additives Petroleum Oils (R & O) For Ambient Temperatures 20 F to 125 F (-6 C to 52 C) Manufacturer Fluid Amoco Oil Company BP Oil Company Chevron Products Company Exxon Company, USA Mobil Oil Corporation Petro-Canada Products Shell Oil Company Texaco Lubricants Company 76 Lubricants Company American Industrial Oil 46 HL-C46 Hydraulic Oil AW 46 Teresstic 46 Mobil Fluid 424 Harmony 46 Turbo T 46 Rando Oil HD Unax AW 46 Petroleum Oils (R & O) For Ambient Temperatures -20 F to 125 F (-28 C to 52 C) Manufacturer Fluid Amoco Oil Company American Industrial Oil 46 Mobil Oil Corporation Mobilfluid 424 Synthetic Oils and Synthetic Transmission Fluids For Ambient Temperatures -40 F to 125 F (-40 C to 52 C) Manufacturer Fluid Conoco Incorporated Syncon R&O 32 Exxon Company, USA Teresstic SHP 32 Mobil Oil Corporation SHC 624 Texaco Lubricants Company Pinnacle 32 Mobil Oil Corporation Synthetic ATF Chevron Synthetic All Weather THF Citgo Transgard Fluid 250 Automatic Transmission Fluids (Dexron or Mercon Oils, etc.) For Ambient Temperatures -40 F to 125 F (-40 C to 52 C) NOTICE: Automatic Transmission Fluids below can only be used with two 140 C fusible plugs Mobil Texaco (Havoline) Citgo Multi-purpose ATF Mercon/Dexron-III or ATF Transgard ATF, Type F ATF Type A and Type Dexron II, lld, lle, lll, Mercon M and M ➀ Refer to the Factory for use of fire resistant fluids. Recommended fluids are typical products only, and should not be construed as exclusive recommendations. Types HFN & HFR Type HFD Type HFDD N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A ( ) NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request.
31
32 866-REXNORD/ (Within the US) (Outside the US) Why Choose Rexnord? When it comes to providing highly engineered products that improve productivity and efficiency for industrial applications worldwide, Rexnord is the most reliable in the industry. Commitment to customer satisfaction and superior value extend across every business function. Delivering Lowest Total Cost of Ownership The highest quality products are designed to help prevent equipment downtime and increase productivity and dependable operation. Valuable Expertise An extensive product offering is accompanied by global sales specialists, customer service and maintenance support teams, available anytime. Solutions to Enhance Ease of Doing Business Commitment to operational excellence ensures the right products at the right place at the right time. Rexnord Corporation Rexnord is a growth-oriented, multi-platform industrial company with leading market shares and highly trusted brands that serve a diverse array of global end markets. Process and Motion Control The Rexnord Process and Motion Control platform designs, manufactures, markets and services specified, highly engineered mechanical components used within complex systems where our customers reliability requirements and the cost of failure or downtime are extremely high. Water Management The Rexnord Water Management platform designs, procures, manufactures and markets products that provide and enhance water quality, safety, flow control and conservation Rexnord Printed in USA 01/14
We will discuss common industrial applications with guides for the proper use of electric motors on these.
INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which
BUT PRECAUTIONS MUST BE TAKEN OR SERIOUS BURNS CAN RESULT.
Cooling System Operation Below is an explanation of this system's operation Radiator The radiator is a device designed to dissipate the heat which the coolant has absorbed from the engine. It is constructed
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
Product Brochure. Controlled start transmission
Product Brochure Controlled start transmission What CST does The Dodge CST (Controlled Start Transmission) is a 2 in 1 gearbox which combines a planetary gear reducer with an integral wet clutch system.
Single Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
TECHNICAL INFORMATION Bulletin
Peerless Pump Company 2005 Dr. M.L. King Jr. Street, P.O. Box 7026, Indianapolis, IN 46207-7026, USA Telephone: (317) 925-9661 Fax: (317) 924-7338 www.peerlesspump.com www.epumpdoctor.com TECHNICAL INFORMATION
TECHNICAL INFORMATION Bulletin
Peerless Pump Company 2005 Dr. M.L. King Jr. Street, P.O. Box 7026, Indianapolis, IN 46207-7026, USA Telephone: (317) 925-9661 Fax: (317) 924-7338 www.peerlesspump.com www.epumpdoctor.com TECHNICAL INFORMATION
Torque control MSF Softstarter
Torque control MSF Softstarter INTRODUCTION Soft starting an AC motor refers to any one of several starting methods that limit the starting current and torque of the motor. The method discussed in this
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
AC Electric Motors best practice
If you want to learn more about best practice machinery maintenance, or world class mechanical equipment maintenance and installation practices, follow the link to our Online Store and see the Training
Cement Processing Overview. Power Transmission Products & Solutions for Cement Processing
Cement Processing Overview Power Transmission Products & Solutions for Cement Processing Choose Rexnord to help you produce tomorrow s cement today. From specification and installation to field monitoring
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
UM Series UniModule. Pre-assembled, C-face Clutches and Brakes. Original Design Sizes 210 & 215. GEN 2 Design Sizes 50, 100 & 180
re-assembled, C-face Clutches and Brakes UniModules offer the ultimate in Clutch/ Brake performance and convenience. UniModules offer the same performance as EM s without the assembly required. Completely
Rotary Phase Converters
FACTS from Ronk Electrical Industries, Inc. Bulletin 11981 Rotary Phase Converters ROTOVERTER Pat. No. 3,670,238 ROTO-CON Pat. No. 4,158,225 What are the ROTO-CON and ROTOVERTER power converters? The ROTO-CON
WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE
WHITE PAPER WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE EXPLANATION AND ASSISTANCE FOR APPLYING SOLID STATE SOFT STARTERS IN TRADITIONAL REDUCED VOLTAGE APPLICATIONS Introduction..............................................................2
Controlled Start transmission
Controlled Start transmission TM What CSt does The DODGE CST (Controlled Start Transmission) is a 2 in 1 gearbox which combines a planetary gear reducer with an integral wet clutch system. When coupled
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
Maxi-Stamper. 200 to 1,000 Tons STAMPING OUT DOWNTIME
TM Maxi-Stamper 200 to 1,000 Tons STAMPING OUT DOWNTIME Standard Features Steel Fabricated Construction Drive Capacity Rated 1/2 Above Bottom of Stroke Self-Diagnostic Solid State Controller Moveable Operator
The Right Drive to Maximize Efficiency and Production for Large Overland Conveyors
The Right Drive to Maximize Efficiency and Production for Large Overland Conveyors By: Nicole Hampton, P.Eng. ABSTRACT: This paper examines various drive systems available for large overland conveyors,
Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.
Lab 13: Wound rotor induction motor. Objective: to examine the construction of a 3-phase wound rotor induction motor; to understand exciting current, synchronous speed and slip in this motor; to determine
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
Checking Wheel Brakes Wear
Issue 1 en 1 Checking Wheel Brakes Wear Contents Disc Brakes... 3 Removing the wheels... 4 Checking the Brake Pads... 5 Check brake disc thickness... 7 Checking brake disc for cracks... 8 Drum Brakes...
SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006
SINGLE PHASE MOTORS INSTALLATION AND MAINTENANCE MANUAL March 21, 2006 Irvine, California (800) 474-0520 Indianapolis, Indiana (800) 866-7973 Hamilton, Ontario (800) 809-0330 e-mail: [email protected]
BIG SAVINGS FOR A LOT MORE APPLICATIONS
MSF SOFT STARTERS BIG SAVINGS FOR A LOT MORE APPLICATIONS Soft Starters from Emotron Unique features built into Emotron MSF Soft Starters reduce costs significantly for many more applications when compared
Fig 1 Power Transmission system of Tractor
POWER TRANSMISSION SYSTEM Transmission is a speed reducing mechanism, equipped with several gears (Fig. 1). It may be called a sequence of gears and shafts, through which the engine power is transmitted
INSTALLATION and OPERATION RANGE BALL CONVEYOR MODEL NO: BC-001AN
Easy Picker Golf Products, Inc. 415 Leonard Blvd. N., Lehigh Acres, FL 33971 PH: 239-368-6600 FAX: 239-369-1579 Service: 800-982-4653 SALES: 800-641-4653 www.easypicker.com [email protected] INSTALLATION
Specifying a Variable Frequency Drive s
Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com
FAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com
FAIRBANKS NIJHUIS FIRE PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS Long established as a leading fire pump manufacturer, Fairbanks Nijhuis offers a broad range of horizontal and vertical split case,
Belt Drives and Chain Drives. Power Train. Power Train
Belt Drives and Chain Drives Material comes for Mott, 2002 and Kurtz, 1999 Power Train A power train transmits power from an engine or motor to the load. Some of the most common power trains include: Flexible
Section 5: Machine Overview
Section 5: Machine Overview Machine Floor Plan Machine Specifications Sequence of Operation Theory of Operation Sensor Location Floor Plan 2007 Douglas Machine Inc. 5.1 Machine Floor Plan Figure 5.1: Machine
Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.
Lab 9: Synchronous motor. Objective: to examine the design of a 3-phase synchronous motor; to learn how to connect it; to obtain its starting characteristic; to determine the full-load characteristic of
Automatic Transmission Basics
Automatic Transmission Basics Lesson Objectives 1. Describe the function of the torque converter. 2. Identify the three major components of the torque converter that contribute to the multiplication of
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
COUNTERBALANCE VALVES
COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE 215.10
OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE 215.10 To Pump model Pump number Our order Your order Order date Reference Item number Destination Plant Before storing, installation, operation or maintenance
Pump Maintenance - Repair
Pump Maintenance - Repair Brian Trombly Mo Droppers Cummins Bridgeway, Gaylord, Mi The basic centrifugal pump consists of two main elements: 1. The rotating element which includes an impeller and a shaft.
AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE
Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE INTRODUCTION In all kinds of manufacturing, it is very common to have equipment that has three phase motors for doing different
Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF
Operating Manual Los Angeles Abrasion Machine HM-70A & HM-70AF Rev: 07/19/2012 PHONE: 800-444-1508 P.O. Box 200, Lewis Center, Ohio 43035-0200 FAX: 800-255-5314 740-548-7298 E-mail: [email protected]
Pure Efficiency. C.C.I.A.A.: N REA. 0195268 Cod. Fiscale e P. IVA: 00483230173 Capitale Sociale versato 100.000,00
Pure Efficiency. The need to significantly reduce the production costs to remain competitive on the global market and the requirement to control and lessen the environmental impact of all activities are
BOWIE PUMPS OPERATION - MAINTENANCE
BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped
High Torque Vane Motors MV015, MV037, MV057, MV125
High Torque Vane Motors MV015, MV037, MV057, MV125 2 Unique vane crossing vane design provides maximum versatility This motor is created around the patented vane crossing vane design, a leading-edge concept
300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 1 HYDRAULIC PUMPS The material needed for outcome 2 is very extensive so there
BSM MOTOR DRIVEN CENTRIFUGAL PUMPS
PRINCIPLE OF OPERATION A hydraulically and dynamically balanced impeller with raised vane sections discharges liquid as a result of the centrifugal force developed in rotation. The head developed is entirely
Class 5 to 7 Truck and Bus Hydraulic Brake System
Class 5 to 7 Truck and Bus Hydraulic Brake System Diagnostic Guide 1st Edition * 5+0 Important Service tes The information in this publication was current at the time of printing. The information presented
The Ultimate Truck Stock Motor
The Ultimate Truck Stock Motor What is a Rescue Motor? Universal Replacement Motor for Condenser Fan and Direct Drive Blower Applications Multi-Horsepower PSC Motors Flexible Mounting Options Permanent
Example. Fluid Power. Circuits
Example Fluid Power Circuits To Enhance Symbol Reading Skills To Work On Circuit Reading Skills With Answers HI LO Pump Circuit 18 A1 B1 17 16 15 13 Set 14 2,000 PSI PG2 Set 500 PSI 12 11 7 8 10 PG1 9
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc. 1 Centrifugal Pump- Definition Centrifugal Pump can be defined as a mechanical device used to transfer liquid of various types. As
AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller
January 2013 AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller Milliken Valve Company 190 Brodhead Avenue, Suite 100 Bethlehem, PA 18017 Phone: (610) 861-8803 Fax:
SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor
INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone:
Hydraulically actuated clutches and spring-applied brakes clutch/brake combined units
왎 Hydraulically actuated clutches and spring-applied brakes clutch/brake combined units Or tlinghaus Plates. Clutches. Brakes. Systems. Hydraulically actuated clutches and spring-applied brakes clutch/brake
Wynn s Extended Care
Wynn s Extended Care Every car deserves to receive the very best care... especially yours. How Do You Keep Your Reliable Transportation Reliable? Count on Wynn s Because Wynn s has been caring for cars
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
TOYOTA ELECTRONIC CONTROL TRANSMISSION
Electronic Control Transmission (ECT) The Electronic Control Transmission is an automatic transmission which uses modern electronic control technologies to control the transmission. The transmission itself,
Fire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
TOPIC: 191004 KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?
KNOWLEDGE: K1.01 [3.3/3.5] P21 Which one of the following contains indications of cavitation in an operating centrifugal pump? A. Low flow rate with low discharge pressure. B. Low flow rate with high discharge
Machine needle shut-off nozzle type-a
Machine needle shut-off nozzle type-a spring operated Applications: Thermoplastics (not applicable for PVC) Shut-off mechanism: Operated with one axial high performance spring Index of contents Chapter
BICO CHIPMUNK JAW CRUSHER - TYPE WD
BICO CHIPMUNK JAW CRUSHER - TYPE WD The Bico Chipmunk Jaw Crusher is designed to give long and efficient service. In order to secure the long life and excellent performance that your crusher is capable
Fire Pump Applications
Fire Pump Applications Installation & Maintenance Manual Universal Joint Driveshafts www.cumminsfirepower.com Table of Contents Section 1 General 1.1 Introduction 1.2 Safety Precautions 1.3 Warranty Statement
Understanding Variable Speed Drives
Understanding Variable Speed Drives April 1, 1997 Solomon S. Turkel, Solomon S. When applied properly, the variable frequency drive (VFD) is the most effective motor controller in the industry today. Modern
Synchronous motor. Type. Non-excited motors
Synchronous motor A synchronous electric motor is an AC motor in which the rotation rate of the shaft is synchronized with the frequency of the AC supply current; the rotation period is exactly equal to
TOYOTA ELECTRONIC TRANSMISSION CHECKS & DIAGNOSIS
Checks and Adjustments The transmission requires regular maintenance intervals if it is to continue to operate without failure. As we discussed in previous sections, transmission fluid loses certain properties
IMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6
- B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &
KINETIC ENERGY RECOVERY SYSTEM BY MEANS OF FLYWHEEL ENERGY STORAGE
ADVANCED ENGINEERING 3(2009)1, ISSN 1846-5900 KINETIC ENERGY RECOVERY SYSTEM BY MEANS OF FLYWHEEL ENERGY STORAGE Cibulka, J. Abstract: This paper deals with the design of Kinetic Energy Recovery Systems
NEW CONVEYOR EQUIPMENT Parts & Services
NEW CONVEYOR EQUIPMENT Parts & Services W E ST R I V E R CO N V E YO R S.CO M BELT DRIVES West River Conveyors + Machinery Co. specializes in new conveyor equipment and belt drives tailored to specific
Speed Control Relays SX2
SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................
SECTION 23 34 13. A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.
PART 1 GENERAL SECTION 23 34 13 HVAC FANS 1.01 SUMMARY A. Section Includes: 1. Exhaust fans. 2. Transfer fans. B. Related Documents: 1. Drawings and general provisions of the Contract, including General
4" SUBMERSIBLE PUMPS
4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant
Armature Actuated Brakes
Armature Actuated s P/N 8-078-890-05 effective 05/02/14 Installation and Service Instructions Series AAB Armature Actuated s Sizes 72 through 170 Model Numbers 33[ ]-1, 33[ ]-2, 33[ ]-3, 33[ ]-4, 33[ ]-5
WINDER SYSTEMS GE Industrial Control Systems
WINDER SYSTEMS Systems Concepts Terminology GE Industrial Control Systems APPLICATION TECHNIQUES With a smooth metal surface material, a paper liner is sometimes wound with a coil. The paper is lightweight
SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION
SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION Introduction Howard W. Penrose, Ph.D., CMRP Vice President, Engineering and Reliability Services Dreisilker Electric Motors, Inc.
Chapter 7 Hydraulic System Troubleshooting
Chapter 7 Hydraulic System Troubleshooting General The following troubleshooting information is provided as a general guide to identify, locate and correct problems that may be experienced with the hydraulic
Rexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
Table of Contents. Transmission Fundamentals
Table of Contents Subject Page Standard/Automatic Transmission Comparison... 3 Hydraulic Transmission vs. Electro-Hydraulic Transmission... 4 Transmission Identification... 5 Transmission Hydraulics...
2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure
2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure Derek Guenther 1/28/2015 Rev. Purpose The purpose of this document is to describe the procedure necessary to replace one of the ball nuts
Digi-Motor Installation Guide
Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support
Vibration analysis: what does it mean?
Vibration analysis: what does it mean? By Chuck Yung Interpreting the vibration signature of plant equipment. Vibration analysis, properly done, allows the user to evaluate the condition of equipment and
Roller Chain Coupling
Roller Chain Coupling Features 1. Simple structure A roller chain coupling consists of one duplex roller chain and two sprockets for a simplex chain. Handling is very simple as both the shafts (driving
Mechanical Installation
Page -1-1. INTRODUCTION AND PURPOSE 1.1. This specification covers the installation, testing and precommissioning of mechanical equipment. Work is to be performed in conjunction with the manufacturer s
Introduction. Upon completion of Basics of AC Motors you should be able to:
Table of Contents Introduction...2 AC Motors...4 Force and Motion...6 AC Motor Construction... 12 Magnetism... 17 Electromagnetism... 19 Developing a Rotating Magnetic Field...24 Rotor Rotation...29 Motor
IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual
IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual 7/09 MN301 Table of Contents Section 1 General Information.................................................. 1-1 Overview........................................................
Webinar Series. Committee. Disc Brake Wheels Off Inspection and Reline. Presents
1 APTA Bus Webinar Technical Series Maintenance Committee Webinar Series Presents Disc Brake Wheels Off Inspection and Reline January 21, 2015 2 Introduction Welcome to today s webinar in which we will
A1000 Cheat Sheet (Open Loop Vector)
A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to
DESIGN CLARIFICATION (DC)
DESIGN CLARIFICATION (DC) Owner: Victor Valley Wastewater Reclamation Authority Date: 03/03/2015 Contractor: W M Lyles Carollo Project No.: 8299A.20 Project Name: Subregional WRPs DC No.: 001 DC Title:
Operataing Manual. Single stage radial Fan. Model MKV/TKV
01.2011 Operataing Manual Single stage radial Fan Model MKV/TKV REITZ-SCHWEIZ VENTILATOR AG Zentweg 11 CH-3006 Bern Telefon +41 (0) 31 / 938 85-85 Telefax +41 (0) 31 / 938 85-86 Internet: www.reitz-schweiz.ch
Service and Maintenance. SEW-EURODRIVE Driving the world
SEW Brakes Service and Maintenance 2 Objectives Upon completion of this session, you will be able to do the following: - Identify the components of an SEW brakemotor - Explain the operation of the SEW
Model RC Armature-Slot- Insulation Folder
Model RC Armature-Slot- Insulation Folder 21 Model RC will handle insulation material up to 8 wide between its guides. Creasing rollers are adjustable sideways to make troughs up to 6 wide. A fixed ruler-guide
Cooling system components, servicing
19-1 Cooling system components, servicing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate protection, cover the cap
Centrifugal Fans and Pumps are sized to meet the maximum
Fans and Pumps are sized to meet the maximum flow rate required by the system. System conditions frequently require reducing the flow rate. Throttling and bypass devices dampers and valves are installed
Rear wheel brakes, servicing. Стр. 1 из 45. Note:
Volkswagen Touareg - Rear wheel brakes, servicing Стр. 1 из 45 46-2 Rear wheel brakes, servicing Rear brakes, FN 44 brake caliper, servicing Note: After replacing brake pads, depress brake pedal firmly
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
Permanent Magnetic Couplings and Brakes for Drive Technology
Tridelta Magnetsysteme A Tridelta Group Company Permanent Magnetic Couplings and Brakes for Drive Technology Raw Materials Magnets Systems and Components Magnet N1 Soft iron N2 Resin Introduction and principals