Fuel Storage & Control Systems Generator Packaging & Enclosures
|
|
- Meryl Park
- 7 years ago
- Views:
Transcription
1 Fuel Storage & Control Systems Generator Packaging & Enclosures Options Include: Double-Walled & Fire Rated Tanks, Hurricane Rated & Sound Attenuated Enclosures phoenixproducts 1727 Bennett Street, Jacksonville, FL Fax
2 fueltanks Aboveground & Sub Base Tanks Envirovault & Fire-Steel UL2085 Protected Aboveground Tanks True double-wall construction with lightweight concrete filled interstitial space UL 2085 listed and labeled Protected aboveground tank for flammable and combustible liquids Fire, vehicle impact and ballistic rated Meets requirements for secondary containment, leak monitoring, spill containment, and overfill protection Inner and outer tanks constructed per UL 142 Steel aboveground tanks for flammable and combustible liquids Six inches of lightweight concrete protection between inner and outer tanks provides minimum two-hour fire rating High-build polyester epoxy glassflake impregnated coating used for salt water submersion protection on offshore platforms, 20,000 hour ASTM B117 salt spray tested Primary and emergency vents standard All fittings and protrusions are stainless steel Steel support channel allow visual tank bottom inspection and air circulation Designed to meet or exceed national, state and local codes No exposed concrete Exceeds liability insurance requirements Engineered for seismic IBC standards Integral earthquake and hurricane tie downs Leak detection space provided Meets NFPA 30 and 30A Options Stairs and platforms (aluminum/galvanized steel) meeting OSHA standards with handrails Stainless steel inner and outer tanks Fuel heaters Stainless steel inner and outer tanks Multiple internal compartments Stainless steel accessory equipment boxes and top/remote fill boxes Fuel monitoring and control systems Tank top hand rails approved by OSHA Day tanks with supply and return pumps Custom color matching Fuel polishing systems Dispensing equipment
3 PowerTank & Double-Wall UL142 Secondary Containment Tanks Steel aboveground tanks for flammable and combustible liquids UL 142 listed and labeled protected aboveground tank for flammable and combustible Meets requirements for secondary containment, leak monitoring, spill containment, and overfill protection No external cross beams or side supports to interfere with generator placement or stairs and walkways Supports generator sets up to 80,000 pounds, with or without enclosures Primary and emergency vents standard Rounded corners allowing proper adherence of industrial grade enamel coating Steel support channel allow visual tank bottom inspection and air circulation Designed to meet or exceed national, state and local codes NFPA 30, 30A, 37 & 110 True double-wall construction for UL certification Exceeds liability insurance requirements Engineered for seismic rating Earthquake and hurricane tie downs Leak detection space provided Options Stairs and platforms (aluminum/galvanized steel) meeting OSHA standards with handrails Fuel heaters Stainless steel fittings, protrusions and fill boxes Stainless steel inner and outer tanks Custom color matching Over-fill spill protection Fuel polishing systems Dispensing equipment Fuel monitoring and control systems Day tanks with supply and return pumps Tank top hand rails approved by OSHA Manway access Remote fill
4 generatorenclosures Genset Enclosures Weather Proof, Sound Attenuated, High Velocity-Hurricane Zone & Agency for Health Care Administration Fully weather, corrosion and wind load resistant all aluminum enclosure Interlocking aluminum panels, make a lightweight and corrosion resistant housing Standing seam sloped roof, mill-finish aluminum Fixed intake louvers with expanded aluminum and gravity dampers on discharge provide water intrusion prevention Weather-proof gasket and stainless steel hardware on 36-inch doors with padlocking handles Reinforced door and roof structure Wind load rating 150 MPH Optional 200 MPH ALL ALUMINUM, CORROSION, WEATHER, WIND & MISSILE-IMPACT RESISTANT ENCLOSURES Optional Certifications Miami-Dade County Notice of Acceptance Department of Business and Professional Regulations Florida Building Code SUPERIOR STRUCTURAL DESIGN & MISSILE IMPACT PROTECTION
5 Enclosure Options Motorized air intake and discharge dampers Stainless steel hold-downs Sound attenuation Three point door latches with padlocking handles Reinforcements at all corners and openings 200 MPH wind load construction PE signed & sealed drawings Interior silencer Interior AC and DC lights with timer switch Exterior emergency stop station Electrical and lighting systems Custom paint matching AHCA Compliance High Velocity Hurricane Zone Rating PROTECTIVE ENCLOSURES FOR ALL GENERATOR SIZES
6 moreproducts Falcon Enclosures & Tanks High quality, economical Fuel Storage and Enclosures for Generators 300kW and Lower UL 142 Listed, FDEP Compliant both inner and outer tanks are completely sealed and pressure tested Meets requirements for secondary containment, leak monitoring, spill containment, and overfill protection Supports generators up to 300KW Accommodates Phoenix Products and factory generator enclosures, both weather-proof and sound attenuated Fill cap, primary vents and emergency vents package standard Steel 2-inch channel supports, allow visual inspection of tank bottom as well as air movement to prevent condensation induced corrosion Black satin industrial grade enamel paint Spill containment with spring-loaded drain valve Leak sensor probe Low and high fuel level floats Interlocking aluminum panels, make a lightweight and corrosion resistant housing Standing seam sloped roof, mill-finish aluminum Fixed intake louvers with expanded aluminum and gravity dampers on discharge provide water intrusion prevention Weather-proof gasket and stainless steel hardware on 36-inch doors with padlocking handles Reinforced door and roof structure Wind load rating 120 MPH; Optional 150 MPH Diesel Director Day Tanks UL 142 double wall secondary containment tanks Optional UL 2085 interstitial concrete filled double wall tanks with 2-hour fire rating Supply & return pumps Control panel with high and low level alarms Leak sensor Emergency and Primary vents Gauge stick Float fuel level Mechanical leak sensor Spare fittings ports Tank drains with ball valve Lockable fill cap Phoenix Products coating system Optional OSHPD certification Diesel Director Remote Fillport Ground level connection to fuel truck fill hose Single or multiple tanks Spill containment Optional control panel and 2, 3 or 4 inch fill pipe sizes with or without booster pumps Lockable, weatherproof stainless steel enclosure Hand pump discharge Two-point alarm for high and leak indication Optional control panel with tank selector, automatic ball valves, digital capacity display Optional stainless steel base stand Additional ball valves UL listed Optional flanged automatic valves Optional fusible link fire valves Optional high capacity pump and motor for fuel transfer from gravity trucks
7 aboutus About Phoenix Products Based in Jacksonville, Florida, Phoenix Products was established in 1991 as a fuel tank supplier. Our heritage differentiates us from other generator packagers because of our expertise in fueling systems. In fact, we pioneered several innovative fueling alternatives, now widely used and required by many regulatory agencies. For example, our patented Fire-Steel Generator Base Tank, which was the first UL2085 listed base tank, is now a regulatory requirement in many jurisdictions. Also, our Pipe Daytank System allows placement of emergency power systems in locations where it once was impractical or simply not allowed. We understand that fueling systems are an integral part of any Emergency Power System design; not an afterthought. Built to Last Phoenix Products is a pioneer in the use of aluminum structures for enclosure design. Most competitive generator packages are built with steel housings. Our interlocking panel design provides the corrosion resistance of aluminum, yet provides the structural integrity of up to a 200 MPH wind rating, and sound attenuation options up to 45 dba reduction. One Call Does It All With more than 20 years of experience and customers in a variety of environments, we are familiar with virtually every possible requirement or expectation. Our fabrication technicians are highly trained, extremely talented and willing to take on challenging builds. So if you have a special need or custom request, just ask. Phoenix Products is committed to providing superior product design, exceptional quality, timely delivery and competitive pricing Bennett Street, Jacksonville, FL Fax phoenix.sales@phoenixprods.com
8 phoenixproducts 1727 Bennett Street, Jacksonville, FL Fax
Industrial Generator Set Accessories
Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Packages Applicable to the following models: 600-1000REOZM Kohler enclosures protect stationary generator sets from the elements,
More informationDual wall sub-base fuel tanks-ibc Certified 30-230 kw DGHCA/CB/CC/DA/DB (4BT3.3G5) DSFAA/B/C/D/E (QSB5G3) DSGAA/B/C/D/E (QSB7G5) DSHAA/B/C/D (QSL9G2)
Dual wall sub-base fuel tanks-ibc Certified 30-230 kw DGHCA/CB/CC/DA/DB (4BT3.3G5) DSFAA/B/C/D/E (QSB5G3) DSGAA/B/C/D/E (QSB7G5) DSHAA/B/C/D (QSL9G2) Description Features Cummins Power Generation diesel
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Fuel Tank Package Applicable to the following: 40REOZJC 50/60REOZJD 80/100/150/200REOZJF 125/180REOZJG 230-275REOZJE 300REOZJ Enclosure
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Snow Enclosure and Subbase Fuel Tank Package Applicable to the following: 80/100/150REOZJF 125REOZJG Enclosure with Standard Subbase Fuel Tank Enclosure with State
More informationMorrison Bros. Co. General Product Specifications
Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Aluminum and Steel and Subbase Fuel Tank Package All Generator Set,, and Fuel Tank Options are UL 2200 Certified. Available Approvals and Listings - UL 2200 Listing
More informationMAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION
Oxford Hills Bus Garage 36 Brown St, Norway, ME Oil Storage Inspection 2/20/14 CONDITIONS OBSERVED Underground Oil Storage: 12,000 gallon underground oil storage tank (split 10,000 gallon diesel/2,000
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Weather/Sound and Subbase Package Applicable to the following: 700-1000REOZDE 750-1000REOZMD Weather Standard Features D Internal-mounted, exhaust silencer with rain
More informationPetroleum Storage Tank Compliance 101
Petroleum Storage Tank Compliance 101 Palm Beach County Board of County Commissioners Department of Environmental Resources Management Petroleum Storage Tank Compliance Section www.pbcgov.com/erm 561-233-2400
More informationTechnical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)
Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil) References: Comm 10 2009 EDITION / NFPA 30 2008 EDITION ITEM DESCRIPTION Comm 10 / NFPA General
More informationRecommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank This specification describes requirements for a Diesel Fuel Day Tank System consisting of one or more fuel tanks, an Electronic
More informationShop Fabricated Aboveground Tank Construction Standards
Shop Fabricated Aboveground Tank Construction Standards Wayne Geyer Steel Tank Institute Fourth Biennial Freshwater Spills Symposium 2002 March 19-12, 2002 Cleveland, OH One key to clean freshwater is
More informationOREGON FIRE CODE Interpretations and Technical Advisories
OREGON FIRE CODE Interpretations and Technical Advisories A collaborative service by local and state fire professionals, along with our stakeholders and customers, to provide consistent and concise application
More informationInspections Standard Operating Procedure 5 Aboveground Storage Tanks
Aboveground Storage Tanks Aboveground Storage Tank Inspection This Standard Operating Procedure describes the steps that campus units that manage aboveground oil storage tanks (ASTs) or containers must
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Fuel Tank Package Applicable to the following: 500REOZVC 550/600REOZVB Enclosure with Standard Tank (12-48 Hour) Enclosure with
More informationMidwest Industrial Tanks
FOR AGRICULTURE AND INDUSTRY Midwest Industrial Tanks Fuel & Oil Storage Solutions Midwest Industrial Tanks Is Your Source For All Of Your Fuel Storage And Fuel Transportation Needs. Our Satisfied Customers
More information~~~~ Brian L. Harper, M.D., M.P.H. Commissioner of Health. Vito Minei, P.E. Director of Environmental Quality
SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES DIVISION OF ENVIRONMENTAL QUALITY ABOVEGROUND OUTDOOR TANK AND ASSOCIATED PIPING DESIGN STANDARDS ~~~~ Brian L. Harper, M.D., M.P.H. Commissioner of Health
More informationElement D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
More informationSection A SPCC Plan Implementation Checklist This section of the report addresses compliance with certain requirements of Federal Regulations 40 CFR 112. I. STATUS OF SPCC PLAN (40 CFR 112.3) YES NO A.
More informationCOMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
More informationWaste Oil Collection / Storage
ENVIRONMENTAL & REGULATORY SERVICES Storage Tank Regulation Section P. O. Box 7837 Madison, Wisconsin 53707-7837 TDD #: (608) 264-8777 http://www.commerce.state.wi.us http://www.wisconsin.gov Jim Doyle,
More informationSecondary Containment Options for Aboveground and Underground Tanks. Wayne Geyer Steel Tank Institute
Secondary Containment Options for Aboveground and Underground Tanks Wayne Geyer Steel Tank Institute Secondary containment tanks first appeared in the United States in the early 1980's, when several local
More informationThe following definitions apply with regard to requirements specified in this document:
GUIDELINES FOR INSTALLATION OF TEMPORARY AND PERMANENT ABOVEGROUND DIESEL FUEL TANKS FOR EMERGENCY AND STANDBY POWER SYSTEMS LOCATED OUTSIDE OF BUILDINGS For Use by Unidocs Member Agencies or where approved
More informationAlabama Air and Waste Regulatory Update
Alabama Air and Waste Regulatory Update September 24, 2015 RSA Activity Center Montgomery, AL New Federal UST Regulations (Effective Date October 13, 2015) What Does This Mean To Me? The Current ADEM Regulations
More informationNFPA31FuelOilPiping 1 Revised 3-1-11
NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Weather Enclosure/ Sound Enclosure/Fuel Tank Package Applicable to the following: 230-450REOZDD 350/400REOZDC 450REOZDB Weather Enclosure Features Fade-, scratch-,
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationSTAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Weather/Sound and Subbase Package Applicable to the following: 600-800REOZM 600-800REOZMB Weather Standard Features Critical silencer, flexible exhaust connector, and
More informationHighland Aboveground Steel Storage Tanks
Highland Aboveground Steel Storage Tanks Working for You and a Clean Environment C O N T E N T S The Highland Advantage 1 Horizontal Tank Construction 2 Fireguard Tanks 4 Dike Tanks 6 AREO Style Dike Tanks
More informationDrum Dispensing Stations
Drum Dispensing Stations O Safely Dispense from 55 Gallon Drums over a Spill Compliant Sump. 1-2-and 4 drum models available Drums are securely held on racks by galvanized positioners Sump and frame constructed
More informationOntario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
More informationSpill Containment Manholes
Spill Containment Manholes 1-2100 Series OPW and Pomeco Spill Containment Manholes are designed to prevent spilled product from entering the soil near the fill and vapor return riser connections on underground
More informationNorthern Region. Underground Storage Tank
California CUPA Northern Region Presents Underground Storage Tank Designated Operators Workshop Workshop Agenda Definitions Tank Construction Corrosion Protection Spill Prevention Overfill Prevention Piping
More informationENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS
Facility Name: ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS The following is intended to be used as a guideline for information required to appear on engineered drawings involving petroleum storage
More informationList of Frequently Utilized Storage Tank Standards and Practices
List of Frequently Utilized Storage Tank Standards and Practices Below is a list of frequently used storage tank standards and practices from organizations that are referenced in 25 PA Code, Chapter 245.
More informationUST RULES CHANGES. Heather Peters, Environmental Specialist
UST RULES CHANGES Heather Peters, Environmental Specialist Today s Topic 2011 Rule package- what s left? Upcoming rule changes Federal Regulation Changes & Testing Protocols How are you doing? 2011 Rule
More informationThe following definitions apply with regard to requirements specified in this document:
GUIDELINES FOR INSTALLATION OF TEMPORARY AND PERMANENT ABOVEGROUND DIESEL FUEL TANKS FOR EMERGENCY AND STANDBY POWER SYSTEMS LOCATED OUTSIDE OF BUILDINGS For Use by Unidocs Member Agencies or where approved
More informationCubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments
Cubetainer The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments Providing Bulk Storage Solutions for Motor Oil, Lubricants, Hydraulic Fluids, ATF, Antifreeze & DEF www.snydercubetainer.com
More informationNFPA 30-2008: Basic Requirements for Storage Tanks
NFPA 30-2008: Basic Requirements for Storage Tanks New York City Metro Chapter Society of Fire Protection Engineers New York, NY February 22, 2011 NFPA 30, Flammable and Combustible Liquids Code Storage
More informationSpill Containers. 517 Series 3 ½ Gallons AST Spill Container. 518 Series 7 ½ Gallon AST Spill Container. 515 Series AST Remote Spill Container
Spill Containers 517 Series 3 ½ Gallons AST Spill Container Installed on aboveground storage tanks for the purpose of containing small spills and drips from the fill nozzle. 3 ½ gallon capacity. Steel
More informationSECTION 22 LIGHTNING PROTECTION SYSTEM
SECTION 22 LIGHTNING PROTECTION SYSTEM 22.01 SCOPE: A. These Specifications shall form a part of the Contract Documents and shall govern construction work for all buildings to be built or modified for
More informationIBC Tote Containment Sumps
IBC Tote Containment Sumps DENIOS Provides More Models- and More Variety of IBC Totes Sumps than any other Manufacturer Painted, Galvanized, Stainless Steel, and Poly models available Models provide storage
More informationApplication for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems
Page 1 of 5 Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems New Hampshire Department of Environmental Services
More informationMOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
More informationSPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN
SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN XXXX FARM (CITY OR COUNTY), MICHIGAN CONTACT (NAME), OWNER CERTIFICATION: I hereby certify that I have examined the facility, and being familiar with the
More informationSince 1978. HMT Inc. 24 Waterway Avenue, Suite 400 The Woodlands, Texas 77380 Ph: +1.281.681.7000 Fax: +1.281.419.7689
WaTER & wastewater HMT Inc. 24 Waterway Avenue, Suite 400 The Woodlands, Texas 77380 Ph: +1.281.681.7000 Fax: +1.281.419.7689 Locations worldwide to service all your needs. VAPORVAULT and ALUMINATOR are
More informationEthanol Vehicle and Infrastructure Codes and Standards Citations
Ethanol Vehicle and Infrastructure Codes and Standards Citations This document lists codes and standards typically used for U.S. ethanol vehicle and infrastructure projects. To determine which codes and
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationFire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
More informationCITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN
CITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN Adopted October 5, 2009 Table of Contents Chapter Description Page 1 Facility Descriptions... 3 1.1 Municipal Power Plant, 1001 Park
More informationFUEL TANKS DOUBLE WALL FUEL TANKS
FUEL TANKS DOUBLE WALL FUEL TANKS Since launching our product line over 65 years ago, Meridian has set the standard in excellence for the storage and handling industry. Meridian has continuously incorporated
More informationUnderground Storage Tanks
Underground Storage Tanks An Informational and Guidance Document for the University Community. Please contact Yale Environmental Health and Safety for latest Regulatory Requirements. A typical UST installation
More informationSECTION 15410 GROUND WATER STORAGE TANKS
SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design
More informationFUEL-OIL PIPING AND STORAGE
CHAPTER 13 FUEL-OIL PIPING AND STORAGE SECTION MC 1301 GENERAL 1301.1 Scope. This chapter shall govern the design, installation, construction and repair of fuel-oil storage and piping systems. The storage
More informationPressure Vessels (Air Compressors) and LPG Tanks
Pressure Vessels (Air Compressors) and LPG Tanks 1. Identification of Workplace Hazard Any container, tank or vessel that contains pressurized material is a potential hazard to employees due to the force
More informationRecommended Practice for Installation of Transit Vehicle Fire Protection Systems
Recommended Practice for Installation of Transit Vehicle Fire Protection Systems Approved October 25, 2007 APTA Fire Safety Working Group Approved May 3, 2008 APTA Bus Safety Committee Approved October
More informationArctic King Fuel Tanks meet the Environment Canada TECHNICAL REQUIREMENTS FOR COLLAPSIBLE FABRIC STORAGE TANKS (BLADDERS) - December 17, 2009
Arctic King Fuel Tanks meet the Environment Canada TECHNICAL REQUIREMENTS FOR COLLAPSIBLE FABRIC STORAGE TANKS (BLADDERS) - December 17, 2009 1. Fuel Bladders a. The fuel bladder should be manufactured
More informationSUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES
SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES 1.0 GENERAL 1.1 Article 12 of the Suffolk County Sanitary Code requires that toxic/hazardous material
More informationDIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012
DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY August 2012 SECTION 2 The storage requirements in Directive 055 apply to upstream petroleum facilities, well sites, and pipelines
More informationChemical Feed System Operation and Design Considerations
PNWS AWWA MAY 7, 2014 EUGENE, OREGON Chemical Feed System Operation and Design Considerations Kevin Batridge Lake Oswego Tigard Water Partnership Austin Peters MWH Global Chemical Delivery and Storage
More informationSection 8 Storage Tanks & Equipment
Section Storage Tanks & Equipment Table of Contents Section Storage Tanks & Equipment Above Ground Horizontal Tanks... -1-4 Containment Sumps...-5 Fillrite AC & Transfer Pumps... -9-10 Fillrite Diesel
More informationSECTION 21 30 16 DIESEL-DRIVEN, FIRE PUMPS
SECTION 21 30 16 DIESEL-DRIVEN, FIRE PUMPS PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Delete between // --- // if not applicable to the project. Also delete any other item or paragraph including
More informationSteel Tank Institute AST Inspections. Dana Schmidt, PE STI/SPFA
Steel Tank Institute AST Inspections Dana Schmidt, PE STI/SPFA Agenda Brief review of SPCC Rule SPCC relevance to small tanks and small facilities. SP001 Standard for Inspection of Aboveground Storage
More informationAboveground Indoor Tank Design Guidelines
Suffolk County Department of Health Services Division of Environmental Quality Aboveground Indoor Tank Design Guidelines ~~~~ Mary E. Hibberd, M.D., M.P.H. Suffolk County Commissioner of Health Services
More informationLAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459
SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
More informationStatic Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?
A Health and Safety Guideline for Your Workplace What is static electricity? What causes it? How is it hazardous? And, most importantly, how can it be controlled? All of these questions will be answered
More informationOPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES
OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES Reference: National Fire Protection Association (NFPA) Pamphlet No. 58 Liquefied Petroleum Gas Code, 2001, Chapter 11 Type of Facility: Petroleum
More informationReliant Series Fuel Tanks. Day Tanks Filtration Tanks Specialty Tanks
Reliant Series Fuel Tanks Day Tanks Filtration Tanks Specialty Tanks Insight Onsite Reliant Series Day Tanks Filtration Tanks Specialty Tanks Page 2 The Simplex Reliant Series is the latest design expression
More informationElement D Services Plumbing
PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses domestic cold, hot and hot water return distribution systems within and to five feet beyond building perimeter. PART 2 - DESIGN CRITERIA 2.01 GENERAL
More informationBERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
More informationMagnum Mobile Generator MMG55 Specifications
Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0
More informationVacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
More informationCONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION
CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION SPECIFICATION EO-5023 REVISION 3 MARCH 2003 REQUIREMENTS FOR
More informationDepending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.
Large Facility Fire Safety Checklists and Logs This package contains checklists to ensure that all fire and life safety equipment are properly inspected. There are also logs on which to record the inspections
More informationREHABILITATION OF MOBILE HOMES R4 34 606
REHABILITATION OF MOBILE HOMES R4 34 606 PURPOSE The purpose of this program is to provide minimum safety standards for homes manufactured before the implementation of the HUD Manufactured Home Construction
More informationLEAK DETECTION ALARM SYSTEM GUIDELINES FOR TOXIC HAZARDOUS/MATERIALS STORAGE
Suffolk County Department of Health Services Division of Environmental Quality LEAK DETECTION ALARM SYSTEM GUIDELINES FOR TOXIC HAZARDOUS/MATERIALS STORAGE ~~~~ Mary E. Hibberd, M.D., M.P.H. Suffolk County
More informationROOF TOP MOUNTED Air Handler Specification
ROOF TOP MOUNTED Air Handler Specification PART 1: GENERAL (Model RT) Mechanical Specification 1.01 WORK INCLUDED A. Provide complete air handling unit(s) suitable for outdoor installation. Contractor
More informationSECTION 15732 AIR CONDITIONING UNIT
SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration
More informationSafe Operating Procedure
Safe Operating Procedure (Revised 3/14) ABOVEGROUND PETROLEUM STORAGE TANKS INTRODUCTION Aboveground storage tanks (ASTs) are used to store petroleum products at several UNL locations. For example, ASTs
More informationReplacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
More informationProperty Policyholder Risk Improvement Report and Hurricane Survey
Risk Engineering Property Policyholder Risk Improvement Report and Hurricane Survey Zurich Services Corporation Risk Engineering 1400 American Lane Schaumburg, IL 60196-1056 847.605.6000 Fax: 847.605.7854
More informationHorizontal Split Case Fire Pumpset Diesel Engine Driven
SERIES Horizontal Split Case Fire Pumpset Diesel Engine Driven Selected Models INTRODUCTION Lubi offers LHCD series state-of-the-art fire pumpset with diesel engine driven, horizontal split case pump.
More informationCompact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw.
Compact pumps from the wastewater experts FLYGT 304, 307, 3068. Power range 0.7.4 kw. Wastewater is unpredictable, Flygt pumps are not If you want a wastewater pump that just works month after month, year
More informationSECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
More informationVDL 53 - Vacuum drying oven for flammable solvents
Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed
More informationDaily Inventory and. Statistical Inventory Analysis. Daily Inventory and Statistical Inventory Analysis (SIA) are inventory control
Introduction: TankSmart Operator Training Class A/B Operators Training Class C Operators Annual UST System Inspections Record Keeping Spills: Cleanup & Reporting Safety Tanks: Double-Walled w/ Continuous
More informationWaste Oil Handling, Spill Containment & Lighting
58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20
More informationReplacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay
Original HVAC Units: Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue Photo Essay One fan motor draws air from the lower section of the unit,
More informationMOTOR FUEL DISPENSING SAFETY
STRATEGIC OUTCOMES PRACTICE TECHNICAL ADVISORY BULLETIN January 2010 MOTOR FUEL DISPENSING SAFETY Fire! Not an alarm anyone wants to hear, especially not when the fire is burning at a major fuel source.
More informationFILLING AND PURGING THE SYSTEM
FILLING INSTRUCTIONS FOR WATER HEATER OR CONDENSING BOILER (City Water) Safety tip: Before beginning, turn off power to boiler and circulator. FILLING AND PURGING Step 1: Close Return Manifold Isolation
More informationSeptember 2008 AFC 4.6.2.1.(2) Page 1 of 5. Maximum Size and Aggregate Capacities of Aboveground Storage Tank Systems at Fuel Dispensing Stations
FIRE CODE VARIANCE September 2008 AFC 4.6.2.1.(2) Page 1 of 5 ISSUE Maximum Size and Aggregate Capacities of Aboveground Storage Tank Systems at Fuel Dispensing Stations The Alberta Fire Code (AFC) limits
More informationDirect Gas Fired [Make-Up Air / Displacement Ventilation / Space Heating] System
Section 15622 AA-Series (rev. 04/16/15) Direct Gas Fired [Make-Up Air / Displacement Ventilation / Space Heating] System Note: Optional items and/or items requiring a choice, are shown between brackets
More informationRecommended Fuel Piping Specification For UPP Piping, UL-971
Recommended Fuel Piping Specification For UPP Piping, UL-971 1.0 General The primary delivery piping system shall be for suction or pressure applications and have semi-rigid coaxial type double wall construction,
More informationREQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION
RESIDENTIAL: REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION 2 COMPLETE SETS OF PRINTS WITH ENGINEERS STAMP ON FOUNDATION PLAN INCLUDING ELECTRICAL, PLUMBING, ETC. SITE PLAN SHOWING HOUSE LOCATION
More informationBP WIND ENERGY POLICIES AND PROCEDURES
BP WIND ENERGY POLICIES AND PROCEDURES Document Control Details 1.0 Purpose/Scope 1.1 This procedure provides the minimum requirements to be followed for the storage of flammable or combustible materials
More informationHeavy-Duty Lube and Fuel Truck Sales Tool
Heavy-Duty Lube and Fuel Truck Sales Tool Contact: Adrian Britt or Mike Kelley @ (678) 639-0099 33,000 lb. Lube/Fuel Truck Contact: Adrian Britt or Mike Kelley @ (678) 639-0099 Example Specification
More information