B. Flexible sheet membranes for eave protection, underlayment, and valley protection. C. Associated metal flashings and accessories. 1.

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "B. Flexible sheet membranes for eave protection, underlayment, and valley protection. C. Associated metal flashings and accessories. 1."

Transcription

1 SECTION PART1 GENERAL 1.01 SECTION INCLUDES A. Asphalt shingle roofing. B. Flexible sheet membranes for eave protection, underlayment, and valley protection. C. Associated metal flashings and accessories SUBMITTALS A. See Section Basic Requirements, for submittal procedures. B. Product Data: Provide data indicating material characteristics, performance criteria, and limitations. C. Samples: Submit two samples of each shingle color indicating color range and finish texture/pattern; for color selection. D. Manufacturer's Installation Instructions: Indicate installation criteria and procedures. E. Manufacturer's Certificate: Certify that products meet or exceed specified requirements QUALITY ASSURANCE A 1.04 WARRANTY Perform Work in accordance with the recommendations of The manufacturer. 1. Maintain one copy of document on site. A. See Section Basic Requirements, for additional warranty requirements. B. Provide Owens Corning Standard System Limited Warranty including ProRated Lifetimelimited warranty against defective materials and workmanship, including related metal flashings, for a period of 40 years after final acceptance. Provide for replacement of defective work at no additional cost to Owner FIELD CONDITIONS A. Do not install shingles or eave protection membrane when surface or ambient air temperatures are below 45 degrees F. PART 2 PRODUCTS 2.01 SHINGLES A. Manufacturers: 1. Owens Corning Corp; Product Tru Definition-Duration: 2. Substitutions: See Section Product Requirements SHEET MATERIALS A. Ice and Water Barrier: Self-adhering polymer-modified asphalt sheet complying with ASTM 01970/01970M; 40 mil total thickness; with strippable treated release paper and polyethylene sheet top surface. 1. Manufacturers: a. Owens Corning; Product WeatherLock Mat-waterproofing underlayment; b. Substitutions: See Section Product Requirements. B. Underlayment: Synthetic non-asphaltic sheet, intended by manufacturer for mechanically fastened roofing underlayment without sealed seams. 1. Minimum Requirements: Comply with requirements of ICC-ES AC 188 for non-self-adhesive sheet. 2. Self Sealability: Passing nail sealability test specified in ASTM M. 3. Flammability: Minimum of Class A, when tested in accordance with ASTM E Liquid Water Transmission: Passes ASTM ROOFING PWA /1

2 5. Fasteners: As specified by manufacturer and building code qualification report or approval, if any. 6. Products: a. Owens Corning: ProArmor. b. Substitutions: See Section Product Requirements ACCESSORIES A. Nails: Standard round wire shingle type, of hot-dipped zinc coated steel, 12 gage, inch shank diameter, 3/8 inch head diameter, of sufficient length to penetrate through roof sheathing or 3/4 inch into roof sheathing or decking. Do not use staples. B. Plastic Cement: ASTM D4586/D4568M, asphalt roof cement as recommended by manufacturer. C. Lap Cement: Fibrated cutback asphalt type, recommended for use in application of underlayment, free of toxic solvents. D. Ridge Vents: Shingle- over roll type, low profile ridge vent with moisture barrier membrane; VentSure Rigid Roll Ridge Vents with Weather PROtector by Owens Corning; E. Static Square Roof Vents: Masterflow R50ABL or approved equal; Black. F. Exhaust Fan Vents: Lomanco Series 700 or approved equal; Black. Contractor verify size with existing METAL FLASHINGS A. Metal Flashings: Provide sheet metal eave edge, open valley flashing, and other flashing indicated. See Section Form flashings to profiles indicated on Drawings. PART 3 EXECUTION 3.01 EXAMINATION A. Verify existing conditions prior to beginning work. B. Verify that deck is of sufficient thickness to accept fasteners. C. Verify that roof penetrations and plumbing stacks are in place and flashed to deck surface. D. Verify roof openings are correctly framed. E. Verify deck surfaces are dry, free of ridges, warps, or voids PREPARATION A. Seal roof deck joints wider than 1/16 inch with deck tape. B. At areas where eave protection membrane is to be adhered to substrate, fill knot holes and surface cracks with latex filler. C. Broom clean deck surfaces before installing underlayment or eave protection. D. Install eave edge flashings tight with fascia boards. Weather lap joints 2 inches and seal with plastic cement. Secure flange with nails spaced 16 inches on center INSTALLATION - ICE AND WATER BARRIER A. Install Ice and Water Barrier from eave edge to minimum 2 ft up-slope beyond interior face of exterior wall and where indicated on drawings. Install Ice and Water Barrier a minimum of 20" each side of valleys. B. Install Ice and Water Barrier in accordance with manufacturer's instructions INSTALLATION - UNDERLAYMENT A. At Roof Slopes Up to 4:12: Install two layers of underlayment over area not protected by eave protection, with ends and edges weather lapped minimum 4 inches. Stagger end laps of each consecutive layer. Nail in place. ROOFING PWA /2

3 B. Install underlayment perpendicular to slope of roof, with ends and edges weather lapped minimum 4 inches. Stagger end laps of each consecutive layer. Nail in place. Weather lap minimum 4 inches over eave protection. C. Items projecting through or mounted on roof: Weather lap and seal watertight with plastic cement INSTALLATION -VALLEY PROTECTION A. Install one ply of smooth surfaced roll roofing (Ice and Water Barrier), minimum 40 inches wide, centered over valleys. B. Weather lap joints minimum 8 inches INSTALLATION - METAL FLASHING AND ACCESSORIES A. Install flashings in accordance with Section B. Weather lap joints minimum 4 inches and seal weather tight with plastic cement. C. Secure in place with nails at 16 inches on center. Conceal fastenings. D. Items Projecting Through or Mounted on Roofing: Flash and seal weather tight with plastic cement INSTALLATION - SHINGLES A. Install shingles in accordance with manufacturer's instructions. B. Place shingles in straight coursing pattern with 5 inch weather exposure to produce double thickness over full roof area. Provide double course of shingles at eaves. C. Project first course of shingles 3/4 inch beyond fascia boards. D. Extend shingles 1/2 inch beyond face of gable edge fascia boards. E. Extend shingles on one slope across valley and fasten. Trim shingles from other slope 2 inches from valley center line to achieve closed cut valley, concealing the valley protection. F. Coordinate installation of roof mounted components or work projecting through roof with weather tight placement of counterflashings. G. Complete installation to provide weather tight service PROTECTION A. Do not permit traffic over finished roof surface. END OF SECTION ROOFING PWA /3

4 THIS PAGE INTENTIONALLY LEFT BLANK

5 PART1 GENERAL 1.01 SECTION INCLUDES SECTION SHEET METAL FLASHING AND TRIM A. Fabricated sheet metal items, including flashings, counterflashings, gutters, downspouts, and other items shown on drawings or required to provide a complete installation. B. Coordination with Section , Asphalt Shingles. C. Miscellaneous items and accessories necessary for a complete job SUBMITTALS A. See Section Basic Requirements, for submittal procedures QUALITY ASSURANCE A. Perform work in accordance with SMACNA 1793 and CDA A4050 requirements and standard details, except as otherwise indicated. B. Fabricator and Installer Qualifications: Company specializing in sheet metal work with 5 years of documented experience DELIVERY, STORAGE, AND HANDLING A. Stack material to prevent twisting, bending, and abrasion, and to provide ventilation. Slope metal sheets to ensure drainage. B. Prevent contact with materials that could cause discoloration or staining PROJECT CONDITIONS A. Coordinate with the work of Section , Asphalt Shingles for flashings, trims and other items related to the completion of that work,and Section , Joint Sealers for sealant work related to this Section. PART 2 PRODUCTS 2.01 SHEET MATERIALS A. Galvanized Steel Drip Edge Flashing: Pre-finished galvanized steel; profile; 2-1/2" Nailing Flange with 1-1/2" drop and 3/8" drip; color brown. B. Pre-Finished Galvanized Steel: ASTM A653/A653M, with G90/Z275 zinc coating; minimum 0.02 inch thick base metal, shop pre-coated with modified silicone coating. 1. PVDF (Polyvinylidene Fluoride) Coating: Superior Performance Organic Finish, AAMA 2605; multiple coat, thermally cured fluoropolymer finish system. 2. Color: As selected by Architect from manufacturer's standard colors ACCESSORIES A. Fasteners: Galvanized steel of appropriate type and spacing for item being fastened. B. Protective Backing Paint for concealed cut edges or concealed scratched finish: Asphaltic mastic, ASTM D Type I. C. Sealant to be Concealed in Completed Work: Non-curing butyl sealant. D. Plastic Cement: ASTM 04586, Type I FABRICATION A. Form sections true to shape, accurate in size, square, and free from distortion or defects. B. Form pieces in longest possible lengths. C. Hem exposed edges on underside 1/2 inch; miter and seam corners. D. Joints: Generally lap four inches minimum and set in compatible sealant. Comply with SMACNA Architectural Sheet Metal Manual. ROOFING PWA /1 SHEET METAL FLASHING AND TRIM

6 E. Fabricate corners from one piece with minimum 18 inch long legs; seam for rigidity, seal with sealant. F. Fabricate vertical faces with bottom edge formed outward 1/4 inch (6 mm) and hemmed to form drip. PART 3 EXECUTION 3.01 EXAMINATION A. Verify roof openings, curbs, pipes, sleeves, ducts, and vents through roof are solidly set, reglets in place, and nailing strips located. B. Verify roofing termination and base flashings are in place, sealed, and secure PREPARATION A. Paint concealed cut or scratched metal surfaces with protective backing paint to a minimum dry film thickness of 15 mil. B. Install underlayment over wood substrate prior to sheet metal installation INSTALLATION A. Secure flashings in place using concealed fasteners. B. Apply plastic cement compound between metal flashings and felt flashings. C. Fit flashings tight in place. Make corners square, surfaces true and straight in planes, and lines accurate to profiles. D. Seal metal joints watertight. E. Secure gutters and downspouts in place using similar fasteners to original installation. F. Slope gutters 1/4 inch per 10 feet, minimum SCHEDULE A. Gutters and Downspouts: Reinstall salvaged gutters and downspouts. B. Flashings Associated with Shingle Roofing, including Valley, Hip, Ridge, Eave, Gutter Edge, Gable Edge. C. Roofing Penetration Flashings, for Pipes and Vents: Replace all existing pipe boots and couterflashings for vents where applicable. END OF SECTION ROOFING PWA /2 SHEET METAL FLASHING AND TRIM

SECTION 073113 ASPHALT SHINGLES

SECTION 073113 ASPHALT SHINGLES 1320 / Talent Community Center 073113-1 ASPHALT SHINGLES PART 1 GENERAL 1.01 SECTION INCLUDES A. Asphalt shingle roofing. B. SBS roof membrane. SECTION 073113 ASPHALT SHINGLES C. Flexible sheet membranes

More information

SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING

SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,

More information

SECTION 07 61 13 STANDING SEAM METAL ROOFING

SECTION 07 61 13 STANDING SEAM METAL ROOFING SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced

More information

GOOD ROOFING PRACTICE STEEP-SLOPE RE-ROOFING ASPHALT SHINGLE ROOFING 1:3 (4/12) AND GREATER

GOOD ROOFING PRACTICE STEEP-SLOPE RE-ROOFING ASPHALT SHINGLE ROOFING 1:3 (4/12) AND GREATER GOOD ROOFING PRACTICE STEEP-SLOPE RE-ROOFING ASPHALT SHINGLE ROOFING 1:3 (4/12) AND GREATER 1 DECK Revised January 6, 2011 1.1 General a) Application of asphalt shingles directly over rigid insulations

More information

SEE JAMB 3/4" 1 1/2" 14 NOTES: 1. SEE DETAIL 1 FOR KEYNOTE MATERIAL DESCRIPTIONS

SEE JAMB 3/4 1 1/2 14 NOTES: 1. SEE DETAIL 1 FOR KEYNOTE MATERIAL DESCRIPTIONS . FACE OF WALL.. STUD CONSTRUCTION WITH FIBERGLASS BATT INSULATION AND FIBERGLASS FACED EXTERIOR GYPSUM SHEATHING WITH JOINTS SEALED USING -PART POLYURETHANE PRIOR TO INSTALLING FLUID APPLIED WEATHER RESISTANT

More information

SECTION ASPHALT SHINGLES

SECTION ASPHALT SHINGLES SECTION 07311 ASPHALT SHINGLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Please visit our website for additional information and contacts.

Please visit our website for additional information and contacts. 1 This manual contains basic information, drawings and guides for installing the Polysand Slate Tile Roofing System on a basic type structure. This manual is a summary of good roofing practices and some

More information

SECTION THERMOPLASTIC MEMBRANE ROOFING (Changed by Addendum 2)

SECTION THERMOPLASTIC MEMBRANE ROOFING (Changed by Addendum 2) SECTION 07 5419 THERMOPLASTIC MEMBRANE ROOFING (Changed by Addendum 2) PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Rigid roof insulation. 2. (Changed by Addendum 1) Mechanically attached single

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed

More information

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standing-seam metal roofing, custom fabricated. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Show installation

More information

B. Samples for Initial Selection: For each type of asphalt shingle ridge vent indicated.

B. Samples for Initial Selection: For each type of asphalt shingle ridge vent indicated. SECTION 073113 - ASPHALT SHINGLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Final inspections are completed by site visit only. Access to fenced yards shall be planned. ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,

More information

SECTION STANDING SEAM METAL ROOFING

SECTION STANDING SEAM METAL ROOFING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 41 13 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Use for roofing sloped 1 in 4 (3 in/ft) or greater. 3. Delete between // // if not applicable

More information

ROOFING. Community Development Department Building Division 952-939-8394 eminnetonka.com

ROOFING. Community Development Department Building Division 952-939-8394 eminnetonka.com ROOFING Community Development Department Building Division 952-939-8394 eminnetonka.com This handout is intended only as a guide and is based in part on the 2007 Minnesota State Building Code and good

More information

Residential Roofing Guide

Residential Roofing Guide Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...

More information

Inspire Slate Starter Piece Hip and Ridge. Height: 13 ½" 13 1/2" Width: 12" Squares/ Pallet. Bundles/ Square

Inspire Slate Starter Piece Hip and Ridge. Height: 13 ½ 13 1/2 Width: 12 Squares/ Pallet. Bundles/ Square October 2015 Inspire Classic Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry

More information

UC Structural Batten Seam Panel

UC Structural Batten Seam Panel UC6 Structural Batten Seam Panel DESCRIPTION The double-lock 2-inch standing seam panels system is mechanically attached with concealed fasteners and sliding clips and installed in a sequential pattern.

More information

Florida Building Code, 5 th Edition SHINGLE ROOFING

Florida Building Code, 5 th Edition SHINGLE ROOFING Florida Building Code, 5 th Edition SHINGLE ROOFING Date Issued/Updated: July 6, 2015 This bulletin addresses the current Building Code roofing and re roofing requirements for shingle roofing systems.

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

Distributed by: BEST MATERIALS LLC, Phoenix AZ Ph: 800-474-7570, 602-272-8128 Fx: 602-272-8014 www.bestmaterials.com Email: Sales@BestMaterials.

Distributed by: BEST MATERIALS LLC, Phoenix AZ Ph: 800-474-7570, 602-272-8128 Fx: 602-272-8014 www.bestmaterials.com Email: Sales@BestMaterials. SECTION 07321 COMPOSITE ROOF TILE Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Composite roof tiles. B. Metal roof flashing. C.

More information

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING

More information

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the

More information

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the

More information

SECTION 07400 STANDING SEAM METAL ROOF

SECTION 07400 STANDING SEAM METAL ROOF SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and

More information

STANDING SEAM SHEET METAL ROOFING

STANDING SEAM SHEET METAL ROOFING STANDING SEAM SHEET METAL ROOFING GENERAL INFORMATION 1.1 For all standing seam metal roofing work consult Columbia University Facilities Exteriors and Historic Preservation group. 1.2 Fabricator is responsible

More information

CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000

CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000 CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000 Details and Installation Guide October 2013 All information, descriptions and dimensions in this manual are current at the time of printing. As always, Custom-Bilt

More information

A. Prefinished, prefabricated structural standing seam roof system with continuous interlocking field formed seams.

A. Prefinished, prefabricated structural standing seam roof system with continuous interlocking field formed seams. SECTION 07411 - PART ONE GENERAL 1.1 SECTION INCLUDES A. Prefinished, prefabricated structural standing seam roof system with continuous interlocking field formed seams. B. Coordinate with installation

More information

SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. This section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,

More information

SECTION 07320 ROOFING TILE

SECTION 07320 ROOFING TILE SECTION 07320 ROOFING TILE PART 1 - GENERAL 1.1 SUMMARY: A. Section Includes: 1. Vitrified clay roofing tiles. 2. Tile accessories. 3. Felt underlayment. 4. Self-adhering sheet underlayment. 5. Snow guards.

More information

Chapter 9: INSTALLING ROOFING

Chapter 9: INSTALLING ROOFING 9.1 LEAK BARRIER (ICE AND WATER SHIELD) 9.2 SHINGLE UNDERLAYMENT 9.3 INSTALLING GUTTER APRON AND GABLE D-EDGE 9.4 INSTALLING SHINGLES 9.5 RIDGE VENT AND CAP Tools needed by each volunteer: Hammer (16 oz.

More information

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers.. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3

More information

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS AC TOPSEAL SELF-ADHERED, GRANULAR SURFACED, SINGLE PLY, LOW SLOPE ROLLED ROOFING 3 X 33.3 = 100 SQ. FT. 10 YEAR MATERIAL LIMITED WARRANTY For Use on Porches / Sheds / Utility Buildings / Accessory Buildings

More information

CHAPTER 7: Building Systems ROOFING SYSTEMS

CHAPTER 7: Building Systems ROOFING SYSTEMS ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen

More information

SECTION 07410 METAL ROOF & WALL PANELS

SECTION 07410 METAL ROOF & WALL PANELS This document specifies Metal Roofing Systems prefinished factory formed metal roofing marketed as MRS System 2500 steel and aluminum roofing systems and includes MRS flashing and Trim. MRS finish is a

More information

SECTION METAL BUILDING SYSTEMS. A. Metal wall and roof panels including gutters and downspouts.

SECTION METAL BUILDING SYSTEMS. A. Metal wall and roof panels including gutters and downspouts. New Football Stadium 13.34.19-1 PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 13.34.19 METAL BUILDING SYSTEMS A. Metal wall and roof panels including gutters and downspouts. 1.02 RELATED REQUIREMENTS A.

More information

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance

More information

G VYCOR DECK PROTECTOR

G VYCOR DECK PROTECTOR G VYCOR DECK PROTECTOR Self-Adhered Flashing Contractor s Guide DECKS AND DETAIL AREAS For longer lasting decks, install Grace Vycor Deck Protector. FROM THE MAKERS OF G Ice & Water Shield What Self-Adhered

More information

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-2134 Reissued 12/2015 This report is subject to renewal 12/2016. DIVISION: 07 00 00 THERMAL

More information

Shingle Installation Guide

Shingle Installation Guide Shingle Installation Guide Getting Started Dedicated to improving the environment, NewTech manufactures roofing tiles that are composed of up to 90% recycled post-industrial plastic. The manufacture of

More information

HERITAGE WOODGATE LAMINATED ASPHALT SHINGLES Dallas, TX

HERITAGE WOODGATE LAMINATED ASPHALT SHINGLES Dallas, TX Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING

More information

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-

More information

SECTION 07411 STANDING SEAM METAL ROOFING

SECTION 07411 STANDING SEAM METAL ROOFING PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Standing-seam metal roof. 2. Metal gutters. 1.2 DEFINITIONS A. Metal Roof Panel Assembly: Metal roof panels, waterproofing membrane (underlayment),

More information

GUIDELINE SPECIFICATIONS

GUIDELINE SPECIFICATIONS GUIDELINE SPECIFICATIONS GORDON SOFFIT-SHIELD - An Exterior Metal Soffit System DIVISION 05 5800 or DIVISION 07 7700 Note To Specifier: SOFFIT-SHIELD should be installed by tradesmen that are experienced

More information

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

A. This Section includes rubberized asphalt sheet membrane waterproofing systems. SECTION 07110 SHEET MEMBRANE WATERPROOFING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

application instructions

application instructions application instructions ARCHITECTURAL COLLECTION CEDAR SHAKE 76 SERIES LAP SIDING General At the time of manufacture, siding meets or exceeds the performance standards set forth in Composite Panel Association

More information

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc. GUIDE SPECIFICATION Manufacturer: DECRA Roofing Systems A Fletcher Building Company 1230 Railroad Street Corona, CA 92882 951-272-8180 phone 951-272-4476 facsimile www.decra.com SECTION 07313 [07 31 13]

More information

3. Where the existing roof has two or more applications of any type of roof covering.

3. Where the existing roof has two or more applications of any type of roof covering. City of Huntington Beach Department of Planning & Building REROOFING REQUIREMENTS 2000 Main Street, Huntington Beach, CA 92648 Office: (714) 536-5241 Fax: (714) 374-1647 This bulletin provides information

More information

XYZ Corporation. Project Waterproofing Handbook. 23 June 2008. Working Set Rev. 0. Project Address: 8888 Main Street York, PA 88888

XYZ Corporation. Project Waterproofing Handbook. 23 June 2008. Working Set Rev. 0. Project Address: 8888 Main Street York, PA 88888 Arch itectu ral Te sting Inc. XYZ Corporation 23 June 2008 Project Waterproofing Handbook Working Set Rev. 0 Project Address: 8888 Main Street York, PA 88888 Prepared By: Architectural Testing 4 Rancho

More information

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc. GUIDE SPECIFICATION Manufacturer: DECRA Roofing Systems A Fletcher Building Company 1230 Railroad Street Corona, CA 92882 951-272-8180 phone 951-272-4476 facsimile www.decra.com SECTION 07314 [07 31 14]

More information

EcoTouch Insulation with PureFiber Technology

EcoTouch Insulation with PureFiber Technology PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

Detached accessory structures that contain no conditioned floor area are exempt.

Detached accessory structures that contain no conditioned floor area are exempt. RESIDENTIAL ROOFING PERMITS: A roofing permit is required for roofing of residential dwellings and garages in accordance with Section R105 of the International Residential Code. Updated 11/2013 City of

More information

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within

More information

PRODUCT SPECIFICATION MASTER

PRODUCT SPECIFICATION MASTER PRODUCT SPECIFICATION MASTER Owens Corning Roofing & Asphalt herein referred to as Owens Corning Section 07311 Fiber glass-based Asphalt Shingles. PART 1 GENERAL 1.1 RELATED SECTIONS A. Rough Carpentry

More information

2.67x7/8 Corugated

2.67x7/8 Corugated 2.67x7/8 Corugated Table of Contents General Notes Handling and Storage 1 Tools and Equipment, Field Cutting Panels 2 Safety 3 Preparing to Install your New Roofing 4 Reroofing Existing Structures 5 Panel

More information

Page 1 of 5

Page 1 of 5 SPECIFICATIONS METAL COMPOSITE MATERIAL WALL PANELS ESTOLGA 3000 DRY SEAL SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES A. Exterior cladding consisting of formed metal composite material (MCM) sheet, secondary

More information

Directions For Applying Malarkey Laminate Shingles

Directions For Applying Malarkey Laminate Shingles S Laminate Shingle Instructions 1 Directions For Applying Malarkey Laminate Shingles GENERAL INSTRUCTIONS Install Malarkey laminate shingles according to building code and local amendments. To qualify

More information

B. Samples for Initial Selection: For each type of asphalt shingle ridge and hip cap shingles and ridge vent indicated.

B. Samples for Initial Selection: For each type of asphalt shingle ridge and hip cap shingles and ridge vent indicated. SECTION 07 31 13 - ASPHALT SHINGLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

TARRANT COUNTY DETAIL STANDARDS

TARRANT COUNTY DETAIL STANDARDS TARRANT COUNTY DETAIL STANDARDS 1. Standard Coping 2. Coping at End Wall 3. Standard Sheet Metal Engagement Details 4. Gravel Guard 5. Gravel Guard Wall Termination 6. Gravel Guard, Gutter, and Downspout

More information

GreenGuard Housewrap Installation Guide

GreenGuard Housewrap Installation Guide 000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be

More information

Although we do a fair amount of residential roofing, my family s breadand-butter. Installing a. Sealants aren t universal

Although we do a fair amount of residential roofing, my family s breadand-butter. Installing a. Sealants aren t universal Installing a Low-Slope Exposed EPDM for roof transition Exposed EPDM for resistance to ice damming Sidewall flashing Done with care, a flat roof can provide 0 years or more of leak-free service Gravel

More information

Installation Instructions for Roofing

Installation Instructions for Roofing Smart-Shingle TM System "The new smart way to install cedar shingles." - This Old House Installation Instructions for Roofing INSTALLATION GUIDE MARKS Shingle-Strip 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

More information

SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING

SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

application instructions

application instructions application instructions architectural collection primed bold profile 120 series lap siding (d5, t4, d8, t5, q4) General At the time of manufacture, siding meets or exceeds the performance standards set

More information

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra 2000. Includes:

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra 2000. Includes: BRIDGE & SUPPLY COMPANY Installation Guide Ultra 2000 Includes: Ultra 2000 Installation Guide Stock Trim Profiles Ultra 2000 Trim Installation Guide Page 2 Table of Contents Ultra 2000 Profile, Colors

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design Basis of Design This section applies to roofing membranes, flashing and accessories. Design Criteria Adhere to the standards and details of the latest editions of the National Contractors Association (NRCA)

More information

application instructions

application instructions application instructions ARCHITECTURAL COLLECTION PRIMED BOLD PROFILE 120 SERIES LAP SIDING (D5, T4, D8, T5, Q4) General At the time of manufacture, siding meets or exceeds the performance standards set

More information

application instructions

application instructions application instructions FOUNDATIONS 76 & 120 SERIES PRIMED PANEL SIDING ARCHITECTURAL COLLECTION REVERSE BOARD & BATTEN AND STUCCO PANEL SIDING General At the time of manufacture, siding meets or exceeds

More information

SECTION 07 41 13.16 - STANDING-SEAM METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION 07 41 13.16 - STANDING-SEAM METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 07 41 13.16 - STANDING-SEAM METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Multi-Width Slate. Widths: 12", 10", 9", 7", 6" Length: 18" Thickness at butt: 1/2" Single-Width Slate

Multi-Width Slate. Widths: 12, 10, 9, 7, 6 Length: 18 Thickness at butt: 1/2 Single-Width Slate N DaVinci Slate Multi-Width Slate Single-Width Slate INSTALLATION GUIDE DaVinci polymer slate is carefully engineered to provide the authentic look and durability of natural slate at a fraction of the

More information

SECTION 07 42 13 METAL WALL PANELS

SECTION 07 42 13 METAL WALL PANELS Mitsubishi Plastics Composites America, Inc. 401 Volvo Parkway Chesapeake, VA 23320 Phone: (800) 422-7270 Fax: (757) 436-1896 E-mail: info@alpolic.com www.alpolic-northamerica.com This MANU-SPEC utilizes

More information

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels Grand Rib-3 / Multi-Purpose / Classic Rib Grand Rib-3 / Multi-Purpose / & Classic Rib Grand Rib 3 panels are a strong,

More information

PSU - WHP ROOF REPLACEMENT

PSU - WHP ROOF REPLACEMENT SECTION 076200 - SHEET METAL FLASHING AND TRIM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Specifications Preformed Metal Wall and Roof Panels Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Section 07410 Preformed Metal Wall and Roof Panels Structural

More information

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find

More information

SECTION 07530 SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

SECTION 07530 SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings. SECTION 07530 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section includes the flowing: 1. Removal of existing roofing membrane. Existing bur roof has one overlay and penetration mastic is asbestos containing.

More information

Rouse Life Sciences Roof Repair or Replacement 07 61 13 SECTION 07 61 13

Rouse Life Sciences Roof Repair or Replacement 07 61 13 SECTION 07 61 13 1. PART 1 - GENERAL 1.1 DESCRIPTION OF WORK SECTION 07 61 13 STANDING SEAM METAL ROOFING 1. This Section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,

More information

ITEM 599.06060008 THERMOPLASTIC MEMBRANE ROOFING

ITEM 599.06060008 THERMOPLASTIC MEMBRANE ROOFING DESCRIPTION Construct adhered membrane roofing system, roof insulation, and vapor retarder in accordance with these specifications. MATERIALS: General: Provide installed roofing membrane and base flashings

More information

Replacement of HVAC Systems February 20, 2015 Cranford Campus

Replacement of HVAC Systems February 20, 2015 Cranford Campus SECTION 092116 - GYPSUM BOARD ASSEMBLIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Titan Old World Spanish Tile

Titan Old World Spanish Tile Installation Guide Titan Old World Spanish Tile Titan Manufacturing Phone: 407-587-5492 Fax: (866) 859-8607 www.titanroofsystems.com Rev 70908 This document includes the recommended and suggested installation

More information

Metal Building Systems Installation and Flashings & Details Guide. Table of Contents

Metal Building Systems Installation and Flashings & Details Guide. Table of Contents Table of Contents Section Page Notes to Designer/User..................1-2 Map of Typical Roof Conditions............3 Fastener Placement.......................4 Fastener Selection........................5

More information

Klip Rib Guide Specifications MANUFACTURER - AEP SPAN 2141 Milwaukee Way, Tacoma, WA 98421, Beech Avenue, Fontana, CA 92337

Klip Rib Guide Specifications MANUFACTURER - AEP SPAN 2141 Milwaukee Way, Tacoma, WA 98421, Beech Avenue, Fontana, CA 92337 Klip Rib Guide Specifications MANUFACTURER - AEP SPAN 2141 Milwaukee Way, Tacoma, WA 98421, 800-733-4955 10905 Beech Avenue, Fontana, CA 92337 This Guide Specification is to be used to develop an office

More information

HHS J.W. Peavy Center Exterior Walls Waterproofing and Roof Replacement Project WBS # H-000018-0006-4 SECTION 07610 STANDING SEAM METAL ROOFING

HHS J.W. Peavy Center Exterior Walls Waterproofing and Roof Replacement Project WBS # H-000018-0006-4 SECTION 07610 STANDING SEAM METAL ROOFING PART 1 - GENERAL 1.01 DESCRIPTION SECTION 07610 A. Furnish and install a weather and watertight prefabricated standing seam roof system complete, in place, as shown on the drawings and as specified herein.

More information

Retrofitting an Insulated Cold Roof

Retrofitting an Insulated Cold Roof Retrofitting an Insulated Cold Roof As a metal-roofing contractor in the Upper Peninsula of Michigan, I am frequently asked to fix roof leaks that have less to do with roofing than with the way poorly

More information

Classic Products, Inc. ClickLock Standing Seam Installation Manual

Classic Products, Inc. ClickLock Standing Seam Installation Manual Classic Products, Inc. ClickLock Standing Seam Installation Manual Classic Products, Inc. 8510 Industry Park Drive Piqua, OH 45356 800.543.8938 Table of Contents page Introduction 1. 1 Starter. 2. 1 Panels.

More information

SECTION RESIDENTIAL OVERHEAD DOORS TRADITIONAL STEEL COLLECTION INSULATED DOORS SERIES

SECTION RESIDENTIAL OVERHEAD DOORS TRADITIONAL STEEL COLLECTION INSULATED DOORS SERIES SECTION 08361 RESIDENTIAL OVERHEAD DOORS TRADITIONAL STEEL COLLECTION INSULATED DOORS - 390 SERIES Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of

More information

Installation Instructions

Installation Instructions Installation Instructions CEDAR BREATHER Page Installation Under Cedar Shingles 2 Installation Under Cedar Shakes 3 Rake & Drip Edge Shingles Detail 4 Rake & Drip Edge Shakes Detail 5 Valley Flashing 6

More information

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS Reference Guide 0.1 GENERAL 0.1 Reference Guide 0.2 Index 0.3 Disclaimer & Limitations 0.4 General Notes

More information

Continuous Dow Corning 791 Silicone Weatherproofing Sealant cap along edge of silicone transition strip. Dow Corning Silicone Transition System (STS)

Continuous Dow Corning 791 Silicone Weatherproofing Sealant cap along edge of silicone transition strip. Dow Corning Silicone Transition System (STS) : Drawing Details Details cap along edge of silicone transition strip Silicone Transition System (STS) Fillet bead of at top of flashing lapped on to flashing, over STS and onto field layer layers staggered

More information

Larry Haight's Residential Roofing Co, Inc 15203 NE 95th Street Redmond, Washington Phone: (425) 881-9771 Fax: (425) 869-1010

Larry Haight's Residential Roofing Co, Inc 15203 NE 95th Street Redmond, Washington Phone: (425) 881-9771 Fax: (425) 869-1010 Larry Haight's Residential Roofing Co, Inc 15203 NE 95th Street Redmond, Washington Phone: (425) 881-9771 Fax: (425) 869-1010 Custom bid generated for: Job site address: Lake Villas Condominium Attention:

More information

application instructions

application instructions application instructions PRECISION SERIES 38 AND 76 SERIES PRIMED LAP SIDING General At the time of manufacture, siding meets or exceeds the performance standards set forth in ICC-ES-AC321 and has achieved

More information

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions All questions and concerns please call 904-696-9700 Discount Direct Metal Roofing Plus Rib metal roofing panels are a strong,

More information

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1501 GENERAL 1501.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies, and

More information

City of Somersworth, New Hampshire OFFICE OF THE FINANCE DIRECTOR

City of Somersworth, New Hampshire OFFICE OF THE FINANCE DIRECTOR Scott A. Smith Finance Director sasmith@somersworth.com (603) 692-9504 One Government Way Somersworth, New Hampshire 03878 (603) 692-4262 www.somersworth.com City of Somersworth, New Hampshire OFFICE OF

More information

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3

More information

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find

More information

Please read the entire document before purchasing and installing any of these products

Please read the entire document before purchasing and installing any of these products Please read the entire document before purchasing and installing any of these products USA SBS UNDERLAYMENT ROOFING UNDERLAYMENT SBS Mineral Surfaced MINERAL SURFACE CAP SHEET Ice and Water Protection

More information

VAIL Metal Shingles. Application Instructions. Custom-Bilt Metals 13940 Magnolia Ave. Chino, CA 91710

VAIL Metal Shingles. Application Instructions. Custom-Bilt Metals 13940 Magnolia Ave. Chino, CA 91710 VAIL Metal Shingles Application Instructions 13940 Magnolia Ave. Chino, CA 91710 VAIL Metal Shingles Application Instructions When installing or walking on VAIL Metal Shingles: 1. OSHA fall protection

More information

Section Page Section Page

Section Page Section Page Western States Western Rib Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer / Installers..1 Fastener Placement and Selection.2-3 Key

More information

112039.00 SECTION 074113.16 STANDING-SEAM MEAL ROOF PANELS

112039.00 SECTION 074113.16 STANDING-SEAM MEAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information