1 Operations Manual for FM41046 Unit # 2193 BULK OIL FILTRATION UNIT Page 1 of 22
2 TABLE OF CONTENTS 1 Introduction 3 2 Calculation of Filtration Time 3 3 Specifications 4 4 System features 5 5 Explanation of Features 7 6 Oil loading process for new elements 8 7 Operation Instructions 9 8 Filter Housings 10 9 Live Oil Sample Point Filter Element Life Element Removal & Refitting Procedure Element Change Procedure System Parts Filter Housing Parts Electrical Schematic Contact Details 22 Page 2 of 22
3 1. INTRODUCTION This mobile filtration system designed to filter the existing oil using the Kidney Loop Filtration process:- Kidney Loop Filtration a filtration process where the oil is pumped from its compartment and directed through the filter element housings and returned to the same compartment of the machine. The oil continues to circulate through this path until cleaned to an acceptable level. 2. CALCULATION OF FILTRATION TIME It is critical to allow adequate filtration time to complete as many cycles of the oil volume as possible. Industry best practice recommends filtering the oil volume by a minimum of seven times to ensure one pass of the oil in the compartment. Filter Technology recommend, where possible, to complete the equivalent of 2 to 3 complete passes, that is 14 to 21 times the volume of the compartment. For example, for a compartment capacity of 800 litres:- 800L x 7 cycles = 5600 litres for one pass L divide by 32L/min flow rate = 175 min. filtration time = 2.9 hours filtration time from one pass = 5.8 hours for 2 complete passes = 8.7 hours for 3 complete passes Page 3 of 22
4 3. SPECIFICATIONS Model Filter Housings Replacement Kit Power Supply Flow Rate Relief Setting Blocked Filter Indication FM off FM Volts 10Amp 15L/min 5 Bar (72.5 PSI) Yes Page 4 of 22
5 4. SYSTEM FEATURES Filter Housings Power Supply Cable Manifold Drain Port Power Supply Plug Live Sample Port Page 5 of 22
6 SYSTEM FEATURES Element Change Light On/Off Isolation Switch Hour Run Metre Emergency-Stop Pressure Gauge Live Sample Port Drip Tray Page 6 of 22
7 5. EXPLANATION OF FEATURES Isolation Switch An Isolation Switch is located to the top left hand corner of the Control Panel. EMERGENCY STOP Button This button is provided for the routine stopping of the system. Hour Run Meter The hour run meter indicates the total hours of operation to date. Element Change Light The Element Change Light will illuminate to indicate that the filter elements require change-out. For further information, see Section 10. Filter Element Life. Pressure Gauge The pressure gauge provides the operator a visual display oil pressure in the filter element housings. Pressure Gauge Page 7 of 22
8 6. Oil Loading Process for New Elements When the FM41046 is first delivered or during a usual service of the filtration unit there is a procedure for the loading of the elements with oil to make the unit operational. If this procedure is not followed the unit will consume an amount of oil that may deplete the volume of the compartment to unsafe levels. Once the filtration unit has been delivered or serviced the process to replenish the new elements is as follows The unit should be placed adjacent to the new oil drum or tote. Attach the unit to a power supply Place the unit into the kidney loop mode (if applicable) Use a suction device to evacuate the oil from the drum or tote Recirculate the oil through the unit back into the drum or tote The unit should be run until pressure of at least 3 bar has been reached this will ensure that the unit has been purged of air and all the elements have been completely encased in oil. Once these conditions have been achieved the suction hose should be removed from the drum or tote and then the unit should be allowed to suck air to pump back as much oil as possible to meet conditions that are usually meet in normal operation. After the unit has pumped as much oil out of its system that is practical it should be stopped isolated and the hoses recoiled back onto the unit ready for general operation. Page 8 of 22
9 7. OPERATION INSTRUCTIONS 1. Place the unit into position near the tank or reservoir that is to be filtered. 2. Attach a suction hose into the nominated take off point. This can be the drain point, and then fit a return hose to the opposite end of the tank or reservoir. This will aid in the cleaning of the compartment. Suction Inlet Point Return Outlet Point 3. Unroll the power lead and plug it into a power source and turn it ON. Plug the power lead into a power source. Page 9 of 22
10 4. The unit is ready to start. Release the Stop Button and Turn the Isolation/Start Switch to the ON position Turn Isolation switch to the ON Position. Release the Emergency Stop button. 5. Allow the unit to run for the time period available. See Section 2. Calculation of Filtration Time for recommended filtration times. 6. When finished, press the red Emergency Stop Button to stop the system. Follow Set-up steps in reverse order to disconnect the system. 8. FILTER HOUSINGS The system is equipped with ten filter housings, each containing four filter elements. See Section 12. Element Change Procedure for details on changing used elements. 9. LIVE OIL SAMPLE POINT One live oil sample point is provided on the pump outlet, before the filters this location provides a representative sample of the oil condition in the compartment. NOTE: As a matter of good practice, when taking any live oil sample, always drain off at least 200ml of oil to flush the sample valve and remove and dead zone oil from behind the sample valve. See Picture below. Page 10 of 22
11 Live Oil Sample point located below the pressure gauge. 10. FILTER ELEMENT LIFE The elements should be changed when:- o The pressure on the gauge rises above 4.5 Bar / 65 PSI with the system at full operating pressure o 500 hours is the recommended maximum element life. Initially, depending on existing oil cleanliness levels, element life may be shorter as residual contamination is removed from each compartment. NOTES 1. The Orange Light on top of the electrical box is to indicate that the elements may require changing. It will activate when the filter inlet pressure exceeds 5 bar The elements must be changed if the Orange Light on top of the electrical box is illuminated. Page 11 of 22
12 11. ELEMENT REMOVAL & REFITTING PROCEDURE 1. Using a clean rag or paper towel, clean away any dirt etc from around the lids of the filter housings. 2. Rotate the housing lid Tee handle anti-clockwise until the thread can be felt to have disengaged in the housing, see Fig Lift the filter assembly only slightly and reposition off-centre so that the centre tube is not engaged in the housing, see Fig. 2. Do not remove element assembly from housing at this stage. 4. Place a drain tray under the drain port, see Fig 4, or connect a waste evacuation hose to the drain port. Allow housings to drain accordingly. 5. Repeat steps 1 to 3 at remaining housings so all can drain ASAP. This will be more effective if the oil is warmer but is worth doing in any case. 6. With a spill container in position, withdraw the used element assemblies from the housings and place them in the spill container to drain further. 7. Change elements on the assembly as per Section 12. Element Change Procedure 8. Insert the clean element assemblies into the housing slowly, being careful not to displace any oil still in the housing causing spillage. 9. Locate the threaded end of the Return tube into the base of the element housing and rotate clockwise to pull the lid into position. Note that there is a lead into the base to make it easier to align and engage the thread, see Fig As the lid engages the housing, take care to ensure the lid seal aligns and enters the housing correctly. 11. Continue to rotate the Tee handle until the lid has pulled up firm on the housing. 12. Rotate the Tee handle 180 to apply final tension to the lid seals. 13. Clean away any spillage. 14. Repeat process on other housings. Page 12 of 22
13 Fig. 1 Element assembly screwed into housing base. Fig. 2 Oil in housing can now drain back to reservoir. Element assembly unscrewed and repositioned off-centre as shown. Fig. 3 Lead into thread Fig. 4 Housing Drain Port Page 13 of 22
14 12. ELEMENT CHANGE PROCEDURE Page 14 of 22
15 Page 15 of 22
16 13. SYSTEM PARTS Item FTA Part Number Technical Description Qty 1 FM3204 Filter Housing No 4 - Industrial 10 2 FM0065 Pressure Gauge ¼ BSP Rear Entry c/w FTA logo 1 3 FMP3010 Live Sample Point 1 4 FMM6012 Live Sample Dust Cover 1 5 FM0348 Relief Manifold 1 6 FM0339 Outlet Manifold 1 7 FM0368 Inlet Manifold 1 8 FME1007 Motor: 240V 0.75kw 1 9 FMP1118 Pump: 15.7cc 1 10 FMP3056 Check Valve 5 Bar x 1" 1 11 FME4005 Pressure Switch High 1 12 FME6292 Emergency Stop Button 1 13 FME6268 Amber Light 240V 1 14 FME5076 Isolation/Start Switch 1 15 FME6251 Hour Run Metre 1 Page 16 of 22
17 SYSTEM PARTS & 4 9 Page 17 of 22
18 SYSTEM PARTS Page 18 of 22
19 SYSTEM PARTS Page 19 of 22
20 14. FILTER HOUSING PARTS Page 20 of 22
21 15. ELECTRICAL SCHEMATIC Page 21 of 22
22 16. CONTACT DETAILS Filter Technology Australia Office: 44 Bonville Ave, Thornton NSW 2322 Postal: PO Box 101, Thornton NSW 2322 Tel: Fax: Toll Free Australia: info@filtertechnology.com.au Page 22 of 22
FILLING AND PURGING THE SYSTEM
FILLING INSTRUCTIONS FOR WATER HEATER OR CONDENSING BOILER (City Water) Safety tip: Before beginning, turn off power to boiler and circulator. FILLING AND PURGING Step 1: Close Return Manifold Isolation
More informationSunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
More informationRexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
More informationStandard Hydraulic Piping Flushing Procedure
Page 1 of 6 1.0 Scope This procedure covers the minimum technical requirements for cleaning and flushing of Hydraulic and Piping, and related accessories. 2.0 Introduction In hydraulic fluid power systems,
More information1998½-2007 Dodge Ram 5.9L Cummins
9 January 2014 1081130-33 Dodge Cummins Low Fuel Pressure Alarm Light Kit (I-00143) 1 1998½-2007 Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual - Part Number Sequence: 1081130
More informationHydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
More informationINSTALLATION MANUAL MODEL RP-150
INSTALLATION MANUAL FOR 24 VALVE 5.9L CUMMINS POWERED DODGE TRUCKS 2003 THROUGH 2004.5 MODEL RP-150 READ THESE INSTRUCTIONS THOROUGHLY BEFORE BEGINNING INSTALLATION 5400 BUSINESS 50 WEST SUITE 8 573 635-0555
More informationINSTALLATION MANUAL MODEL RP-100
INSTALLATION MANUAL FOR 24 VALVE 5.9L CUMMINS POWERED DODGE TRUCKS 2003 THROUGH 2004.5 MODEL RP-100 READ THESE INSTRUCTIONS THOROUGHLY BEFORE BEGINNING INSTALLATION 5400 BUSINESS 50 WEST SUITE 8 573 635-0555
More informationMODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
More informationWaste Oil Handling, Spill Containment & Lighting
58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20
More informationWaters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
More informationNot required for most applications Not required for most applications High pressure (12-803 provided) High pressure (12-803 provided)
ELECTRIC FUEL PUMPS P/N 12-801-1, 712-801-1, 12-802-1, 712-802-1, 12-815-1, & 712-815-1 FUEL PRESSURE REGULATORS P/N 12-803, 12-501, 12-804, 12-500, & 15812NOS Installation Instructions THESE INSTRUCTIONS
More informationIMPORTANT SAFETY RULES TO FOLLOW
WARNING FLOOR & CARPET CLEANER Any piece of equipment can be dangerous if not operated properly. YOU are responsible for the safe operation of this equipment. The operator must carefully read and follow
More information15CI and 25CI Reversing Motor Pumpset Owner's Manual
ComNav Marine Autopilots #15-13511 Crestwood Place Richmond, BC Canada V6V 2G1 Telephone: 604-207-1600 Fax: 604-207-8008 In Canda or the U.S.A: Toll Free Phone: 1-800-428-0212 Toll Free Fax 1-800-470-9611
More informationOil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
More informationRMF TANDEM 900 OFF-LINE FILTER SYSTEMS
RMF TANDEM 900 OFF-LINE FILTER SYSTEMS RMF Tandem 900 Off-line filter Systems can be applied to every imaginable industrial application where hydraulic or lubrication systems are present. An integrated
More informationInstallation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
More informationTable of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19
Table of Contents Overview 1 Pump Disassembly 2 Control Disassembly / Reassembly 7 Pump Reassembly 13 Adjustment Procedures DR Control 19 Adjustment Procedures DRG Control 20 Adjustment Procedures DFR
More informationVolkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)
47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing
More informationSHOT BLAST CABINET MODEL NO: CSB20B
SHOT BLAST CABINET MODEL NO: CSB20B PART NO: 7640110 USER INSTRUCTIONS GC0216 INTRODUCTION Thank you for purchasing this CLARKE Shot Blast Cabinet which is designed for professional workshop use. Before
More informationExample. Fluid Power. Circuits
Example Fluid Power Circuits To Enhance Symbol Reading Skills To Work On Circuit Reading Skills With Answers HI LO Pump Circuit 18 A1 B1 17 16 15 13 Set 14 2,000 PSI PG2 Set 500 PSI 12 11 7 8 10 PG1 9
More informationSCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.
SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of
More information2003 ACCORD - Automatic Transmission Removal
2003 ACCORD - Automatic Transmission Removal Special Tools Required Engine support hanger, A and Reds AAR-T-12566 Engine hanger balancer bar VSB02C000019 Front subframe adapter VSB02C000016 These special
More informationINSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR
INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR INTRODUCTION The Cirro MK 3 is a fully professional mist generator for producing sufficient airborne reflection particles to enable effect lighting to
More informationLINDGREN-PITMAN, INC. Super Spool III Installation Instructions
LINDGREN-PITMAN, INC. Super Spool III Installation Instructions LINDGREN-PITMAN, INC. 2615 N.E. 5th Avenue * Pompano Beach, Florida 33064 * U.S.A. (954)943-4243 * (954)943-7877 Fax E-mail: longline@gate.net
More informationInstallation Instructions 6028.801
DAZZLE Installation Instructions 08.80 Spread Lavatory Faucet with Speed Connect Drain* Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American
More informationB150 Series Commercial Brewer. Direct Plumb Kit
B150 Series Commercial Brewer Welcome Keurig Authorized Dealer! Direct Plumb Kit This manual provides: Installation of the Direct Plumb Kit (DPK) that allows you to connect your customer s B150 brewer
More informationInstallation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
More informationVOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
More informationStainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
More informationVolkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)
17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning
More informationCompressor Service & Maintenance Manual
Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance
More informationWALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS
1 WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS Please read and follow all these instructions carefully before proceeding with the installation,
More informationDraining and filling cooling system
Page 1 of 9 Draining and filling cooling system Special tools and workshop equipment required Adapter -V.A.G 1274/8- Pipe -V.A.G 1274/10- Drip tray -V.A.G 1306- or drip tray for workshop hoist -VAS 6208-
More informationCooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
More information123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD E3 009B MM Rev 1 Nov. 2010 INTRODUCTION The purpose of this manual
More informationTech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet Address: http://www.powerteam.
ORIGINAL INSTRUCTIONS Form No.102842 5 SPX Hydraulic Technologies 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800)
More informationMaster Catalogue I August 2011
Master Catalogue I August 2011 Greasing Equipment Drum Pumps Hose Reels Vehicle Hoists Wheel Service Equipment Lubrication Systems 58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile
More informationStanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide
Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide Brochure 99795, updated August 2002 1. Introduction Stanadyne has been making diesel fuel filters for over 30 years. Stanadyne
More informationNITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
More informationNESCAFÉ Solution 8/60 Beverage System. Operations Manual
NESCAFÉ Solution 8/60 Beverage System Operations Manual 1 INDEX & WARNINGS INDEX Warnings SECTION: 1 INDEX & WARNINGS SECTION: 2 BASIC PARTS OF THE MACHINE SECTION: 3 LOADING PRODUCTS SECTION: 4 DISPENSING
More informationACCUMULATOR INSTALLATION
7001-7 ACCUMULATOR INSTALLATION BRAKE ACCUMULATORS I 308L93 Rae 7-59710 Issued 6-93 Printed in U.S.A 7001-8 Removal ACCUMULATOR VALVE 1. Park the machine on a level surface and lower the. loader bucket
More informationPUMP AND MOTOR DIVISION
INSTALLATION MANUAL SERIES P2 and P3 MOBILE PISTON PUMP 1 Check model code / compare with your paper work Nameplate of the pump Ordering / Sales Acknowledgement 2 Check rotation of the pump Clockwise rotation
More information367 000 Suction assembly for 1.000 l IBC and 205 l drums 1.060 mm suction tube. 367 003 Suction assembly for tanks 1.600 mm suction tube.
PUMPMASTER 2 accessories, other MOBILE oil dispensers PumpMaster 2 Accessories 01 OIL PUMPS 360 1 360 120 367 000 367 011 369 910 360 1 Wall bracket 360 120 Floor bracket 360 001 Bung adaptors 2" (M) connection
More informationUNITOR VACUUM cleaners
UNITOR VACUUM cleaners Unitor VCD15 a compact, heavy-duty dry vacuum cleaner for accommodation areas The smallest unit in the Unitor range, the VCD15 is purpose-made for use on cruise and passenger vessels.
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationPOSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
More information- Do not immerse cords, pump or any electrical wire or device in water or other liquid.
TRANSFER PUMP INSTRUCTIONS FOR THE SUPER TRANSFER PUMP 1. Pump (water may be present in the pump and lines due to testing at factory) 2. Instructions. 3. Inlet thicker wall hose (1), outlet hose (1) 4.
More informationINSTALLATION AND SERVICE MANUAL
CI8100 IMI Wilshire, Inc. IMI WILSHIRE, INC. COUNTER INTELLIGENCE BEVERAGE SYSTEM CI8100 INSTALLATION AND SERVICE MANUAL 1993 IMI Wilshire, Inc. TABLE OF CONTENTS CI8100 IMI Wilshire, Inc. SECTION I CI8100
More informationZenith Solar thermal 4.5m pump station Installation manual
Zenith Solar thermal 4.5m pump station Installation manual Product code: 20026145 INSTALLATION MANUAL WATER RETURN GROUP This instruction manual is an integral part of the installation and maintenance
More informationUsed Fluid Handling Portable Used-Oil Gravity Drains
Portable Used-Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)
More informationInstallation, Operating and Servicing Instructions. Electric Auto-Fill Push Button Water Boilers EB3F/PB and EB3F/PBM
Installation, Operating and Servicing Instructions Electric Auto-Fill Push Button Water Boilers EB3F/PB and EB3F/PBM Please make a note of your product details for future use: Date Purchased: Model Number:
More informationPresented by Rory S. McLaren. SAFE by DESIGN
Presented by Rory S. McLaren Copyright 2013 1 Hydraulic safety doesn t just happen, it has to be pursued! Safety MUST be the nucleus of hydraulic system design. The responsibility of safe design must be
More informationWHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 gpm@gpmhydraulic.com www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS
More informationVALET MACHINE WET & DRY 30LTR.
INSTRUCTIONS FOR VALET MACHINE WET & DRY 30LTR. MODEL NO: VMA914 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
More informationReduced Pressure Principle Assembly 3 Valve Procedure
Reduced Pressure Principle Assembly 3 Valve Procedure A. Initial Setup 1. Flush test cocks by: a. opening test cock #4 to establish flow through the unit. (Leave this test cock open until others are flushed)
More informationNexus FS Point of Use Installation Guide
Nexus FS Point of Use Installation Guide Nexus FS POU Install Guide:12152011:rev-12152011 Technical Specifications Dimensions: Height: 43.5 Width: 11.65 Depth: 15 Weight: 34.39 LBS Electrical Specs: Voltage:
More informationCLEAN AND CLEAR PLUS CARTRIDGE FILTER
CLEAN AND CLEAR PLUS CARTRIDGE FILTER INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL SUPPORT If you
More informationLine to Refrigerator Ice/Water Dispenser
Standard 18 Line to Refrigerator Ice/Water Dispenser Pump Module Bottled Water How The System Works The FLOJET Bottled Water Dispensing System was designed to pump water from a commercially available 5-gallon
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationTechnical data. Danfoss DHP-A
Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationCooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
More informationCDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
More informationIn addition to the basic models, it is also possible for the units to be outfitted with add-ons.
1-1202-EN Gear ump Units For single-line centralized lubrication systems MFE5-KW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,
More informationROUGHNECK II Pumpless Drain
SERVICE BULLETIN SB4027 Rev. I 1/11 For Used Oil Only ROUGHNECK II Pumpless Drain Model #4110-022 FOR USED OIL ONLY (Black) For Antifreeze Only Model #4110-023 FOR USED ANTIFREEZE ONLY (Green) Patent #
More informationCOOLANTCLEAN III Engine Cooling System Service
MOTORVAC TECHNOLOGIES INC. COOLANTCLEAN III Engine Cooling System Service MANUAL #200-8232PL Operator s Manual Table of Contents Introduction. 3 Overview...4 System Features and Functions.....1-1 Control
More informationBF Series Sa S n u d p Fe i r l C t l e e r a n Installation Manual -1-
Installation Manual -1- What happens to the water in your pool? This should be a question of prime consideration for all pool owners. In the past some pools did not use filtering systems, the owner was
More informationETL listed for installations within 5 ft. (1.5M) of outer edge of water www.srsmith.com 79-15152-00 Rev E2 9.14 Page 1 of 10
Color Light Streams Large Laminar Installation Manual (CLSLL) Input Power: Total Power: 12V AC 5W 4008814 ETL listed for installations within 5 ft. (1.5M) of outer edge of water 79-15152-00 Rev E2 9.14
More informationPortable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
More informationBuy Karcher Parts Online: www.pressureparts.com. Need Technical Help? Call: 1-800-999-2245 email Requests to: sales@pressureparts.
Karcher Model: K 620-M * ( 59556440 ) - Parts Section:1.1 TOP PART Page 1 of 18 1 50346460 1 STRAP 2 63031250 6 SCREW 3 50670230 1 COVER 4 63031940 2 SELF-TAPPING SCREW 5 50309650 1 COVER 6 50635710 1
More informationHydraulic Flow Control Valves
Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
More informationAir-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)
Service Manual Model No. PM5200 Series PM5300 Series (shown) SAVE THESE INSTRUCTIONS 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067 USA Fax: (+001) 610-262-6080 www.precisionmedical.com
More informationAuto-belay Cable Replacement Process
Auto-belay Cable Replacement Process Version 2.00 WARNING: The air pressure in the auto-belay system is what causes the cable to be retracted when releasing the cable or climbing the wall with the cable
More informationSHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24
SHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24 OPERATING & MAINTENANCE INSTRUCTIONS 1205 PARTS & SERVICE For Spare Parts and Service,please contact your nearest dealer, or CLARKE International,
More informationBench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
More informationCoolflo Safe Touch Shower Mixing Valve ST20015CP
Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept
More informationINSTANT HOT WATER RECIRCULATING SYSTEM
INSTANT HOT WATER RECIRCULATING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Save manual for future reference MODEL 500800 Warning Please read carefully before proceeding with installation. Your failure
More informationRotary IBC AdBlue Pump
Installation, Operating, Maintenance & Safety Instructions Rotary IBC AdBlue Pump RHP105 Important Information It is important to ensure that this pump is both handled and operated in accordance with the
More informationAMX300 DirectConnect Mixing Valve Kits
AMX300 DirectConnect Mixing Valve Kits INSTALLATION INSTRUCTIONS Tools needed (not supplied) 1. Wrench 2. Pliers Safety Definitions These safety terms identify information you must read. CAUTION Indicates
More informationCHEMICAL CLEANING UNIT Product number: 737189
CHEMICAL CLEANING UNIT Product number: 737189-1 - v.05/16 Content Page Intro 3 Specifications 4 Installation 5 Safety precautions 7 Maintenance 8 Spares and Accessories 8 Unitor Chemicals 9 Notes 10-2
More informationSALEEN SPEEDLAB SERIES VI STANDARD SC UPGRADE KIT
SALEEN SPEEDLAB SERIES VI STANDARD SC UPGRADE KIT INSTALLATION MANUAL: 2005 MUSTANG 4.6 3V MANUAL P/N: 10-8002-C14338C SUPERCHARGER KIT P/N: 10-1607-B14083* Saleen Performance, Inc. 1225 East Maple Rd.,
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationRecord Cleaning Machine
Record Cleaning Machine Owner s Manual UK December 2010 Photo 1 Photo 2 IMPORTANT! READ THIS OWNER S MANUAL CAREFULLY, BEFORE USING THE MACHINE! Introduction You are now the proud owner of an Okki Nokki
More informationAuxiliary Rams USERS MANUAL
Auxiliary Rams 2007 Chief Automotive Technologies, Inc. Chief s Limited One-Year Warranty & Liability CHIEF'S LIMITED ONE-YEAR WARRANTY & LIABILITY Chief Automotive Technologies, Inc. warrants for one
More informationDANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information
Safety Safety Is Your Responsibility DANGER To avoid personal injury or death, carefully read and understand all instructions pertaining to the Anthony Liftgates product. Do not attempt to install, operate,
More informationAIR OPERATED OIL PUMPS AND KITS
PM 2 AIR OPERATED OIL PUMPS AND KITS PM 2 Oil pump, pressure ratio : 0 Double acting air operated pumps for transferring lubricants and other non-corrosive fluids. Pump includes bung adapter. New Model
More informationPWC-500/1000/1010/1500
SERVICE MANUAL for by Vertex Model PWC-500/1000/1010/1500 P/N man-7008 Table of Contents Introduction Cooler Set-up Remove Top Cover Remove/Replace Float Remove/Replace Hot Tank Faucet Repair Hot Tank
More informationDavcron Concrete Agitator - Operations Manual
Davcron Concrete Agitator - Operations Manual THE DAVCRON AGITATOR MUST BE OPERATED BY TRAINED AND AUTHORISED PERSONNEL ONLY DAVCRON ENGINEERING PTY LTD General Engineering & Maintenance Contractors -
More informationG R O U P. ISO 9001:2008 Certified
If Your Fluid Storage Area Looks Like This... IFH Has a Better Solution. G R O U P Innovative Fluid Handling Group ISO 9001:2008 Certified Take the Innovative Approach: The IFH Fluid Storage and Dispensing
More informationRecharge Procedure for Telemark TVP-2000 and TVP-3500
Recharge Procedure for Telemark TVP-2000 and TVP-3500 Required items: 1.) Refrigeration service manifold. 2.) Charge recovery system. 3.) Dry nitrogen gas. If a high pressure cylinder is used, a pressure
More informationGVE 370 CT 370 CT 380 CT 470
Owner Instructions Warning! Read instructions before using the machine GVE 370 CT 370 CT 380 CT 470 www.numatic.com Contents / Kits - A26A / A40A / A43 2 3 Wet - Assembling the machine for extraction use
More informationEVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board. This Troubleshooting Guide covers the electric coolant valve and control
More informationOil Filtration Systems. Filtakleen By-Pass Oil Filter INSTALLATION INSTALLATION & & SERVICE MANUAL MANUAL
Filtakleen By-Pass Oil Filter Oil Filtration Systems INSTALLATION INSTALLATION & & SERVICE MANUAL MANUAL xx INTRODUCTION The Filtakleen By-Pass oil Filter is an ultra-fine 1 micron Bypass filtration system
More informationSELECTION, APPLICATION & MAINTENANCE
DIESEL PROTECTION SYSTEMS TPZ Engine Air Intake Shut Down Valves (Combined Automatic Overspeed and Air Pressure Operated Shut Down Bendix Types) SELECTION, APPLICATION & MAINTENANCE Valve Numbers TPZ-101
More informationArtisan Thermostatic bath shower mixer. Fitting Instructions & Contents List
Artisan Thermostatic bath shower mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts Contents Page 1. Introduction 03 2. Specification
More informationTroubleshooting Guide for Jacks Down LED Lights
Troubleshooting Guide for Jacks Down LED Lights Equalizer Systems Auto-Level systems manufactured after 2005 feature a pressure switch system that monitors the retracted state of leveling jacks and any
More informationSELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
More informationQuik Lining Systems Heater Owners Guide
Quik Lining Systems Heater Owners Guide Quik Lining Systems, Inc is pleased to present the Quik Heater, an innovative heater used to cure cured in place pipe for sewer laterals. The unit is the most cost
More information