G3PE-Three-phase. Solid State Contactors for Heaters
|
|
- Laureen Richards
- 7 years ago
- Views:
Transcription
1 Solid State Contactors for Heaters Three-phase CSM_Three-phase_DS_E_4_1 Compact, Slim-profile SSRs with Heat Sinks. Solid State Contactors for Three-phase Heaters Reduced Installation Work with DIN Track Mounting. RoHS compliant. Surge pass protection improved surge dielectric strength for output currents. (OMRON testing) Slim design with 3-phase output and built-in heat sinks. DIN Track mounting types and screw mounting types are available. All DIN Track mounting types mount to DIN Track (applicable DIN Track: TR3-1Fe (IEC 671)). Conforms to UL, CSA, and EN standards (TÜV certification). Refer to Safety Precautions for All G3PE s. Ordering Information List of s s with Built-in Heat Sinks Number of phases Three-phase Insulation method Phototriac coupler Operation indicator Rated input voltage Zero cross function Yes (yellow) 12 to 24 VDC Yes Type Applicable load *1 Number of poles 3 21B-3N DC A, to 24 VAC 2 21B-2N DC B-3N DC A, to 24 VAC 2 22B-2N DC B-3N DC A, to 24 VAC 2 23B-2N DC B-3N DC12-24 DIN track mounting *2 Screw mounting 4 A, to 24 VAC 1 A, 2 to 48 VAC 2 A, 2 to 48 VAC 3 A, 2 to 48 VAC 4 A, 2 to 48 VAC 1 A, to 24 VAC 2 A, to 24 VAC 3 A, to 24 VAC 4 A, to 24 VAC 1 A, 2 to 48 VAC 2 24B-2N DC B-3N DC B-2N DC B-3N DC B-2N DC B-3N DC B-2N DC B-3N DC B-2N DC B-3 DC B-2 DC12-24 *3 3 22B-3 DC B-2 DC B-3 DC B-2 DC B-3 DC B-2 DC B-3 DC B-2 DC12-24 *3 3 2B-3 DC A, 2 to 48 VAC 2 2B-2 DC B-3 DC A, 2 to 48 VAC 2 3B-2 DC B-3 DC A, 2 to 48 VAC 2 4B-2 DC12-24 *1. The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page. *2. The applicable DIN Track is the TR3-1Fe (IEC 671). For details, refer to the mounting information in the Safety Precautions for All G3PE s. *3. DIN Track or Screw mounting. 1
2 Three-phase s with Externally Attached Heat Sinks Number of phases Three-phase Insulation method Phototriac coupler Operation indicator Rated input voltage 3 4B- DC A, 2 to 48 VAC 2 4B- DC12-24 * The rated load current depends on the heat sink or radiator that is mounted. It also depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature. Accessories (Order Separately) Heat Sink Heat resistance Rth (s-a) ( C/W) Zero cross function Yes (yellow) 12 to 24 VDC Yes 1.67 Y92B-P 1.1 Y92B-P.63 Y92B-P1.43 Y92B-P2.36 Y92B-P2 Type Applicable load * Externally attached heat sinks 1 A, to 24 VAC 2 A, to 24 VAC 3 A, to 24 VAC 4 A, to 24 VAC 1 A, 2 to 48 VAC 2 A, 2 to 48 VAC 3 A, 2 to 48 VAC Number of poles 3 21B- DC B- DC B- DC B- DC B- DC B- DC B- DC B- DC B- DC B- DC B- DC B- DC B- DC B- DC
3 Three-phase Specifications Certification UL8, CS2.2 No.14, and EN Ratings (at an Ambient Temperature of 2 C) Operating Circuit (All s) Item Rated operating voltage Operating voltage range Rated input current (impedance) Must-operate voltage Must-release voltage Insulation method Operation indicator Same for all models 12 to 24 VDC 9.6 to 3 VDC 1 ma (24 VDC) 9.6 VDC 1 VDC min. Phototriac Yellow LED Main Circuit of s with Built-in Heat Sinks Item 21B- 21B- 22B- 22B- 23B- 23B- *1. The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page. *2. Applicable Load Use the following formula to calculate the maximum total capacity of a heater load for a three-phase balanced load with delta connections. Maximum load capacity = Load current Load voltage 3 Example: 1 A 2 V 3 =,196 W.1 kw Example: 1 A 4 V 3 = 1,392 W 1.3 kw Main Circuit of s with Externally Attached Heat Sinks Permissible I 2 t (reference value) 121A 2 s 26A 2 s 1,26A 2 s 26A 2 s 1,26A 2 s Applicable load (resistive load: AC1 Refer to Engineering Data on page. class) * The rated load current depends on the heat sink or radiator that is mounted. It also depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page. 24B- Rated load voltage to 24 VAC 2 to 48 VAC Operating voltage range 7 to 264 VAC 18 to 28 VAC Rated load current *1 1 A (at 4 C) 2 A (at 4 C) 3 A (at 2 C) 4 A (at 2 C) 1 A (at 4 C) 2 A (at 4 C) 3 A (at 2 C) 4 A (at 2 C) Minimum load current.2 A. A Inrush current resistance (peak value) Permissible I 2 t (reference value) Applicable load (resistive load: AC1 class) *2 Item 1 A 22 A 44 A 24B- 1B- 1B- 2B- 22 A 2B- 3B- 3B- 4B- 44 A 121A 2 s 26A 2 s 1,26A 2 s 26A 2 s 1,26A 2 s.1 kw (at 2 VAC) 21B- 21B- 8.6 kw (at 2 VAC) 22B- H 22B kw (at 2 VAC) 23B- 23B- 1. kw (at 2 VAC) 24B- 24B- 12. kw (at 48 VAC) 1B- 1B- 2.7 kw (at 48 VAC) 2B- 2B- 29. kw (at 48 VAC) 3B- 3B- 4B kw (at 48 VAC) Rated load voltage to 24 VAC 2 to 48 VAC Operating voltage range 7 to 264 VAC 18 to 28 VAC Rated load current * 1 A (at 4 C) 2 A (at 4 C) 3 A (at 2 C) 4 A (at 2 C) 1 A (at 4 C) 2 A (at 4 C) 3 A (at 2 C) 4 A (at 2 C) Minimum load current.2 A. A Inrush current resistance (peak value) 1 A 22 A 44 A 22 A 4B- 44 A 4B- 3
4 Three-phase Characteristics s with Built-in Heat Sinks Item Operate time Release time Output ON voltage drop Leakage current * Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient storage temperature Ambient operating temperature Ambient operating humidity Weight 21B- 21B- 22B- 22B- 1/2 of load power source cycle + 1 ms 1/2 of load power source cycle + 1 ms 23B- 23B- 24B- 24B- 1B- 1B- 1.6 V (RMS) 1.8 V (RMS) 2B- 1 ma (at 2 VAC) 2 ma (at 48 VAC) MΩ min. (at VDC) 2, VAC, /6 Hz for 1 min DIN Track mounting: 1 to to 1 Hz,.17-mm single amplitude (.3-mm double amplitude) Screw mounting: 1 to to 1 Hz,.37-mm single amplitude (.7-mm double amplitude) 294 m/s 2 (reverse mounting: 98 m/s2) 3 to C (with no icing or condensation) 3 to 8 C (with no icing or condensation) 4% to 8% 1.2 kg 1.4 kg 1.2 kg 1.6 kg 1.4 kg 2. kg 1.6 kg 1.2 kg 1.4 kg * The leakage current of phase S will be approximately 3 times larger if the 2-element model is used. 2B- 1.2 kg 3B- 1.6 kg 3B- 1.4 kg 4B- 2. kg 4B- 1.6 kg s with Externally Attached Heat Sinks Item 21B- 21B- 22B- 22B- 23B- 23B- 24B- 24B- 1B- 1B- 2B- 2B- 3B- 3B- 4B- 4B- Operate time 1/2 of load power source cycle + 1 ms Release time 1/2 of load power source cycle + 1 ms Output ON voltage drop 1.6 V (RMS) 1.8 V (RMS) Leakage current * 1 ma (at 2 VAC) 2 ma (at 48 VAC) Insulation resistance MΩ min. (at VDC) Dielectric strength 2, VAC, /6 Hz for 1 min Vibration resistance 1 to to 1 Hz,.37-mm single amplitude (.7-mm double amplitude) Shock resistance Destruction: 294 m/s 2 Ambient storage temperature 3 to C (with no icing or condensation) Ambient operating temperature 3 to 8 C (with no icing or condensation) Ambient operating humidity 4% to 8% Weight 3 g * The leakage current of phase S will be approximately 3 times larger if the 2-element model is used. Heat Sinks Y92B-P Y92B-P Y92B-P1 Y92B-P2 Y92B-P2 Weight 4 g 4 g 6 g 8 g 1,2 g 4
5 Engineering Data Three-phase Input Voltage vs. Input Impedance and Input Voltage vs. Input Current Input current (ma) Input impedance (kω) Input current Input impedance Input voltage (V) Input current (ma) Input impedance (kω) 1 Ta = 2 C Input current 7 6 Input impedance Input voltage (V) Load Current vs. Ambient Temperature s with Built-in Heat Sinks 21B-, 22B- 23B-, 24B- 21B-, 22B- 23B-, 24B- 1B-, 2B- 3B-, 4B- 1B-, 2B- 3B-, 4B- Load current (A) B- 22B- 2B- 2B- 21B- 21B- 1B- 1B Ambient temperature ( C) Load current (A) B- 23B- 3B- 3B- 24B- 24B- 4B- 4B Ambient temperature ( C) * * The dotted lines in the charts are the UL derating curves for the 23B-, 24B-, 23B-, 24B-, 3B-, 4B-, 3B-, 4B-. s with Externally Attached Heat Sinks 21B-(-) 23B-(-) 22B-(-) 24B-(-) 1B-(-) 3B-(-) 2B-(-) 4B-(-) Load current (A) B-(-) 2B-(-) Load current (A) 1 23B-(-) 24B-(-) 3B-(-) 4B-(-) B-(-) 1B-(-) Ambient temperature ( C) Ambient temperature ( C)
6 Three-phase Inrush Current Resistance: Non-repetitive Keep the inrush current to below the inrush current resistance value (i.e., below the broken line) if it occurs repetitively. 21B-(H) 21B-(H) Inrush current (A. Peak) B-(H), 2B-(H) 22B-(H), 2B-(H) 1B-(H), 1B-(H), Inrush current (A. Peak) B-(H), 3B-(H) 23B-(H), 3B-(H) 24B-(H), 4B-(H) 24B-(H), 4B-(H) Inrush current (A. Peak) , 3,, , 3,, , 3,, Energized time (ms) Heat Sink Area vs. Load Current (4 C and 8 C) 22B- 2B- Heat sink area (cm 2 ), 3, 1,, 3, 1, 3 Ambient temperature + 8 C Ambient temperature + 4 C Aluminum plate t = 3. Heat sink area (cm 2 ), 3, 1,, 3, 1, 3 Ambient temperature + 8 C Energized time (ms) Ambient temperature + 4 C Aluminum plate t = 3. Energized time (ms) Note: The heat sink area is the combined area of all surfaces of the heat sink that radiate heat. For the 2B-, when a current of 18 A flows through the SSR at 4 C, the graph shows that a heat sink area of about 2, cm 2 would be required. Therefore, if the heat sink is square, one side of an aluminum plate in the heat sink must be 36 cm or longer ( 2, (cm 2 )/2 = 36 cm (rounded to a whole number)) Load current (A) Load current (A) s with Externally Attached Heat Sinks Heat Resistance Rth (Junction/SSR Back Surface) Rth ( C/W) 21B B-.7 23B-.7 24B-.7 Heat Resistance of Heat Sinks Rth ( C/W) Y92B-P 1.67 Y92B-P 1.1 Y92B-P1.63 Y92B-P2.43 Y92B-P2.36 Note: If a commercially available heat sink is used, use one that has a heat resistance equal to or lower than a standard OMRON Heat Sink. 6
7 Dimensions Three-phase Note: All units are in millimeters unless otherwise indicated. Solid State Relays s with DIN Track Mounting 21B-3N 21B-2N 22B-2N 1B-3N 1B-2N 2B-2N Two, R2.3 mounting holes. Two, 4.6-dia. mounting holes Four, 8 dia. Two, M3. 24 Six, M ± ±.3 21B-3N 2@B-2N s with DIN Track Mounting 22B-3N 23B-2N 2B-3N 3B-2N Two, R2.3 mounting holes Two, 4.6-dia. mounting holes Four, 8 dia. Two, M Six, M (3-A type) Six, M4 (2-A type) ± ±.3 22B-3N 23B-2N 2B-3N 3B-2N 7
8 Three-phase s with DIN Track Mounting 23B-3N 24B-2N 3B-3N 4B-2N Two, 4.6-dia. mounting holes Four, 8 dia. Two, M Two, R2.3 mounting holes. 64±.3 Six, M ±.3 23B-3N 24B-2N 3B-3N 4B-2N s with DIN Track Mounting 24B-3N 4B-3N Two, 4.6-dia. mounting holes Four, 8 dia. Two, M3. Two, R2.3 mounting holes ±.3 Six, M ±.3 G3PE24B-3N 4B-3N 8
9 Three-phase s with Screw Mounting 21B-2 1B dia DIN Track or screw mounting. Six, M4 Two, 4. dia. or M4 Two, M elliptical hole ±.3 ±.3 21B-2 1B-2 s with Screw Mounting 21B-3 Four, R2. 22B-2 1B-3 2B Two, M3. Six, M For screw mounting only 6±.3 7 ±.3 21B-3 22B-2 1B-3 2B-2 9
10 Three-phase s with Screw Mounting 22B-3 23B-2 2B-3 3B-2 Four, R Two, M3.. Six, M (@3B-2) Six, M4 (@2B-3) For screw mounting only ±.3 7 ±.3 22B-3 23B-2 2B-3 3B-2 s with Screw Mounting 23B-3 24B-2 3B-3 4B-2 Four, R Two, M3. Six, M For screw mounting only ±.3 7 ±.3 23B-3 24B-2 3B-3 4B-2 1
11 Three-phase s with Screw Mounting 24B-3 Four, R2. 4B Two, M3. Six, M For screw mounting only ±.3 24B-3 4B-3 ±.3 s with Externally Attached Heat Sinks 21B- Four, 4. dia. Four, 8 dia. 21B- 22B- 22B- 23B- 23B- 24B- 24B- 1B-. 1B- 2B- 2B- 3B- 3B- 4B- 4B- 24 Two, M3. ±.3 8 Six, M4 (@1B-@H/-@2B-@H) Six, M (@3B-@H/-@4B-@H) dia. 4. dia. ±.3 11
12 Three-phase Accessories (Order Separately) Heat Sink Y92B-P (Mounts to DIN Track.) For 21B- and 1B- 4.6 dia. Two, 4. dia. or M4 Heat Sink Y92B-P For 21B-, 22B-, 1B-, and 2B- Four, M elliptical hole 8 ±.3 9±.3 Four, R ±.3 6±.3 7 Heat Sink Y92B-P1 For 22B-, 23B-, 2B-, and 3B- Heat Sink Y92B-P2 For 23B-, 24B-, 3B-, and 4B- Heat Sink Y92B-P2 For 24B- and 4B- Four, M4 Four, M4 M4-D1 Four, M Four, R Four, R M4-D1 Four, R ±.3 9±.3 1±.3 ±.3 ±.3 ±.3 12
13 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 211 All Right Reserved.
Solid State Relays for Heaters
New Product Solid State Relays for Heaters Single-phase G3PE Compact, Slim-profile SSRs with Heat Sinks. Models with No Zero Cross for a Wide Range of Applications. RoHS compliant. Models also available
More informationCQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
More informationEE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.
Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the
More informationOrdering Information. Latching Relay G2AK. Model Number Legend G2AK-@@@@@ 1 2 3 4 5. Magnetic Latching Version of G2A Ideal for Sequence Control
Latching Relay CSM DS_E_4_1 Magnetic Latching Version of G2A Ideal for Sequence Control Double-winding latch system with continuous rating. Terminals pulled from the respective junctions between the built-in
More informationEE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws
Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) CSM DS_E_7_2 Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs provided.
More informationVAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.
Pushbutton Switch (Cylindrical 10.5-dia.) CSM DS_E_4_4 Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment Momentary operation and lock. available in six colors.
More informationHL-5000. Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.
General-purpose Limit Switch CSM DS_E_3_ Economical, Miniature Limit Switch Boasting Rigid Construction The Head, Box, and Cover mate with ridged surfaces to maintain strength. A unique Head structure
More informationTina 2A/B Adaptor unit
Original instructions Tina 2A/B Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
More informationSmile 11 AS-i Emergency stop with safe AS-i input node
Original instructions Smile 11 AS-i Emergency stop with safe AS-i input node SAFETY AT WORK ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand
More informationResolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360
Absolute 60-mm-dia. Rotary Encoder CSM DS_E_7_ Rugged Rotary Encoder Absolute model. External diameter of 60 mm. Resolution of up to 1,024 (10-bit). IP65 oil-proof protection. Strong shaft. Radial: 120
More informationOriginal instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
More informationE2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test
Inductive Proximity Sensor in full metal housing Full body stainless steel housing for highest mechanical protection Low frequency modulation for metal chip immunity Flame retardant cable for high protection
More informationType Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC
Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,
More informationGeneral-purpose Relays
General-purpose Relays MK-S New Model General-purpose Relays Featuring Mechanical Indicator and Lockable Test Button Built-in operation indicator (mechanical and LED), and new models with lockable test
More informationSolid State Relays with Built-in Current Transformer
Product News Solid State Relays with Built-in Current Transformer Built-in CT: A New Concept in SSRs! The SSR can now detect heater burnout and SSR short-circuit failure. Heater Burnout Detection SSR Short-circuit
More informationG7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm
Slim Plug-In Safety Relay Slim Safety Relay for Machine Control H Slim body only 13 x 24 x 50 mm (six poles) H Four-pole and six-pole models are available H Terminal arrangement simplifies PCB pattern
More informationOrdering Information. Specifications. Electrode Holder PS-@S(R)/-31. Electrode Holders. Accessories (Order Separately)
Holder PS-@S(R)/-31 Separate Holders for Water Supply and Drainage Control in Buildings. Small, Lightweight Holders for Use as Built-in Components. The PS-@S(R) are separate Holders that allow the s to
More informationE8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.
Digital Sensor CSM DS_E_4_3 Sensor with Easy-to-Read LED Display status can be checked at a glance from the digital display and bar display. Measurement pressure prevents incorrect outputs due to momentary
More informationType Terminal Coil Contact form Model
General Purpose Relay MK Exceptionally reliable general purpose relay. Long life (minimum 100,000 electrical operations) assured by silver contacts. Built-in operation indicator (mechanical, LED), diode
More information3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long
Surfacemounting Relay Ultracompact and Slim DPDT Relay Suitable for highdensity mounting.(.7 mm (W). mm (L) 9 mm (H)). Dielectric strength of, VAC and an impulse withstand voltage of 2, V for 2 μs (conforms
More informationSafety Manual BT50(T) Safety relay / Expansion relay
Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document
More informationE2K-L. Liquid Level Sensor. Applications. Ordering Information. E-68 Proximity Sensors
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
More informationSPST-NO SPDT DPST-NO DPDT
PCB Relay Next-generation PCB Relay Available in 2 Models Low profile:. mm max. in height Contains no lead inside and features cadmium-free contacts ensuring environment-friendly use. Conforms to VDE0
More informationPhase-sequence Phase-loss Relay
New Product Phase-sequence Phase-loss Relay K8DS-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Lineup includes a 17.5-mm slim, compact model. Greater resistance to inverter
More informationThree-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA
Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA Ideal for 3-phase voltage asymmetry monitoring for industrial facilities and equipment. Monitor voltage asymmetry, phase sequence, and
More informationTactile Switch B3F Through-hole-mounting Switches in a Wide Range of Models: 6 6 mm, 12
Tactile Switch BF Through-hole-mounting Switches in a Wide Range of Models: mm, mm, Side-operated Models, Gold- Contacts, and Radial Tape Extended mechanical/electrical durability: 0 x 0 operations for
More informationModel Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
More informationModel Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More information1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) HIGH INSULATION Insulation distance (between coil and
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More informationLiquid Leakage Sensor Amplifier
9 Liquid Leakage Sensor Amplifier Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity 1 Detects leakage of liquid such
More informationGeneral-purpose Relay
General-purpose Relay An Improved Miniature Power Relay with Many Models for Sequence Control and Power Applications A wide range of relay variations including ones with operation indicators, high-capacity
More informationSPST-NO SPDT DPST-NO DPDT
PCB Relay A Power Relay for a Variety of Purposes with Various Models Conforms to VDE (EN680-), UL08, CSA22.2. Meets EN6033- requirements for household products. Clearance and creepage distance: 8 mm/8
More informationXG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement
Flat Cable Connectors for PCBs XG2 Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring IDC connections allow you to wire all terminals at once without terminating the cable. Can
More informationAluminum Electrolytic Capacitors Power Eurodin Printed Wiring
Aluminum Electrolytic Capacitors Power Eurodin Printed Wiring 00/0 PEDPW Fig. QUICK REFERENCE DATA DESCRIPTION VALUE 00 0 Nominal case size (Ø D x L in mm) x 0 to 0 x 00 Rated capacitance range 0 μf to
More informationSolid-State Relays. Series Included. Solid-State Relays SIR...145 SLR...146 NLF...147. PHS Series PHS...148
Solid-State Relays Included SIR....145 SLR....146 NLF....147 PHS PHS....148 Solid-State Relays 144 www.ssac.com 800-843-8848 fax: 605-348-5685 Solid-State Relay - Isolated SIR1 & SIR2 Designed for industrial
More informationAluminum Electrolytic Capacitors Power Economic Printed Wiring
Aluminum Electrolytic Capacitors Power Economic Printed Wiring 0/0 PECPW 00/0 PEDPW Fig. QUICK REFERENCE DATA DESCRIPTION high ripple current 0/0 PECPW long life 0 C Nominal case size (Ø D x L in mm) Rated
More informationSILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES
FTR-K1 SERIES SILENT POWER RELAY 1 POLE - 78A/120A Inrush Current Type FTR-H3 Series FEATURES Pin compatible with widely used VS and FTR-H1 series power relays Silent relay with patented unique U-shape
More informationConductive Level Controller
Conductive Level Controller 61F-GP-N2 Automatic Water Supply and Drainage Control Ideal for level control of any conductive liquid. Compact plug-in controller for single- or two-point control of conductive
More informationPower Resistor Thick Film Technology
Power Resistor Thick Film Technology LTO series are the extension of RTO types. We used the direct ceramic mounting design (no metal tab) of our RCH power resistors applied to semiconductor packages. FEATURES
More informationD2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.
Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Extra-long stroke even without levers. (:.7 mm) Clip contacts with highly reliable slide contact
More informationG6K-2F G6K-2F-Y G6KU-2F-Y
Low Signal Relay G6K Fourth generation design. Design based on worldwide communications, computer peripheral and office automation relay requirements. Offers excellent board space savings. Meets 2.5 kv
More information1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) High insulation Insulation distance (between coil and
More informationNA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES
FTR-K1 SERIES MINIATURE RELAY 2 POLES - 1 to 2 A (For Signal Switching) NA Series FEATURES Slim type relay for high density mounting Conforms to Telcordia specification and FCC Part 68 - Dielectric strength
More informationOptocoupler, Phototransistor Output, with Base Connection
Optocoupler, Phototransistor Output, with Base Connection FEATURES i794-4 DESCRIPTION This datasheet presents five families of Vishay industry standard single channel phototransistor couplers. These families
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More information1a/1c 5A/10A small power relays
VDE a/c A/A small power relays RELAYS RoHS compliant FEATURES High electrical noise immunity High switching capacity in a compact package High sensitivity: mw (a), mw (c) High surge voltage:, V between
More information1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C
FTR-K1 SERIES POWER RELAY 1 POLE - 16A / Inrush 120A relay FTR-K1-KS Series FEATURES 1 pole 16A, 1 form A or 1 form C Peak inrush current 120A / TV-8 Coil power 400mW High insulation in small package (between
More informationSuperTan Extended (STE) Capacitors, Wet Tantalum Capacitors with Hermetic Seal
SuperTan Extended () Capacitors, Wet Tantalum Capacitors with Hermetic Seal FEATURES SuperTan Extended () represents a major breakthrough in wet tantalum capacitor Available technology. Its unique cathode
More informationSlim Relay G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations
Slim Relay G3RV The World's First Industrial Slim Relay G2RV compatible LED indicator built in SSR Push-in terminals and accessories for easy wiring. Model Number Structure Model Number Legend G3RV-SL
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationHow To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
More information650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
More informationTab (#110) terminal Actuator
Snap Action Switch SS Subminiature Snap Action Switch Economical, subminiature snap action switch offers long service life (30 million operations minimum) All models are free from overtravel restrictions,
More informationOptocoupler, Phototransistor Output, Dual Channel, SOIC-8 Package
ILD25T, ILD26T, ILD27T, ILD211T, ILD213T Optocoupler, Phototransistor Output, Dual Channel, SOIC-8 Package i17925 A1 C2 A3 C4 i17918-2 8C 7E 6C 5E DESCRIPTION The ILD25T, ILD26T, ILD27T, ILD211T, and ILD213T
More informationSolid-State Timer H3G
ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationChrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
More informationPower Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
More informationNX safety stand-alone
NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O
More informationPower Resistor for Mounting onto a Heatsink Thick Film Technology
DIMENSIONS in millimeters Power Resistor for Mounting onto a Heatsink Thick Film Technology FEATURES 800 W at 85 C bottom case temperature Wide resistance range: 0.3 to 900 k E24 series Non inductive Easy
More information1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
More informationMaintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series. DRT2-series Smart Slave Analog I/O Terminals
CS-series Net Unit CSM DS_E_5_1 A Net Unit for the CS Series That Boasts Industry-leading Performance and Functions Features Allows control of up to 32,000 points (2,000 words) per master, and ensures
More informationPower ratings Input voltage Output Voltage Output current Boost Current Model number 120 W 2-phase and 3-phase
New Product Switch Mode Power Supply S8VK-T (120/240/480/960 W Models) Worldwide 3-phase Power Supply Resistant in tough environments Easy and fast installation The most compact class on the market Wide
More informationProximity Sensor with All-stainless Housing
NEW Proximity Sensor with All-stainless Housing Highly Durable Proximity Sensor for Tough Environments One-piece completely stainless-steel housing with a face thickness of.8 mm! The face thickness is
More informationMAXIMUM LOAD CURRENT 1 A SN SERIES
SOLID STATE RELAY (I/O Module) MAXIMUM LOAD CURRENT 1 A SN SERIES RoHS compliant FEATURES I/O modules for interface between CPU and external input devices or loads Ultra slim and light weight, SIL s type
More informationSurface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications
Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications ELECTRICAL SPECIFICATIONS X7R GENERAL SPECIFICATION Note Electrical characteristics at +25 C unless otherwise specified
More informationSmall-diameter Proximity Sensor
Small-diameter Proximity Sensor EE Ultra small size, but surprisingly easy installation! With the addition of M,.-dia. size, unshielded, pre-wired connector model, and connector model, a total of 0 model
More informationPOWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES
POWER RELAY POLE - 6A / Inrush 20A relay FTR-K-KS Series FTR-K SERIES FEATURES pole 6A, form A or form C Peak inrush current 20A / TV-8 Coil power 400mW High insulation in small package (between coil and
More informationG6K. Surface Mounting Relay with the World s Smallest Mounting Area. Model Number Legend. Application Examples. Surface Mounting Relay
with the World s Smallest Mounting Area Subminiature model as small as.2 (H). (W) (L) mm is ideal for high-density mounting ((U)-2F(-Y)). Low profile of.2 mm improves mounting efficiency ((U)-2F(-Y)).
More informationRelés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
More informationSpecifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS
Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD Present Value: 8 mm (.32 in) Set Value: 4 mm (.16 in) Nonsignificant
More informationSZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control
Power Relay FEATURES Small package design ARC barrier equipped Silver Cadium Oxide contact High dielectric strength (,800 Vac) High reliability and long life Ultra-high sensitivity with quick response
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationS112-XHS. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information
Description Features The S112-X is a bi-directional, single-pole, single-throw, normally open multipurpose solid-state relay. The circuit is composed of one input IR LED with a series limiting resistor
More information1 Form A Solid State Relay
1 Form A Solid State Relay Vishay Semiconductors DIP i1791- SMD DESCRIPTION Vishay solid state relays (SSRs) are miniature, optically coupled relays with high-voltage MOSFET outputs. The LH1518 relays
More information650W Single Output Power Supply
AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent
More informationAbsolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
More informationSurface Mounting Relay
Surface Mounting Relay Surface Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm Subminiature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density
More information1 POLE - 8A Medium Load Control
POWER RELAY 1 POLE - 8A Medium Load Control JS Series FEATURES UL class B (130 C) coil wire insulation 1 form A (SPST-NO) or 1 form C (SPDT) contact Low profile and space saving - Height: 12.5 mm - Mounting
More informationSurface Mounting Relay
Surface Mounting Relay Surface Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm Subminiature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density
More informationCircuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
More informationAluminum Electrolytic Capacitors Axial Miniature, Long-Life
Aluminum Electrolytic Capacitors Axial Miniature, Long-Life 38 AML 0 ASM smaller dimensions Fig. QUICK REFERENCE DATA DESCRIPTION Nominal case sizes (Ø D x L in mm) 6.3 x.7 to 0 x 5 VALUE 0 x 30 to x 38
More informationStandard Recovery Diodes, Generation 2 DO-5 (Stud Version), 95 A
Standard Recovery Diodes, Generation 2 DO-5 (Stud Version), 95 A 95PF(R)... DO-203AB (DO-5) PRODUCT SUMMARY I F(AV) Package Circuit configuration 95PF(R)...W DO-203AB (DO-5) 95 A DO-203AB (DO-5) Single
More informationChrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationOptocoupler, Phototransistor Output, with Base Connection
4N25, 4N26, 4N27, 4N28 Optocoupler, Phototransistor Output, FEATURES A 6 B Isolation test voltage 5000 V RMS Interfaces with common logic families C 2 5 C Input-output coupling capacitance < pf NC 3 4
More informationDLP-PU/E Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
More information1 Form A Solid State Relay
Form A Solid State Relay VOAT, VOAABTR FEATURES 9 S S DC S' 3 S' High speed SSR - t on /t off < 8 μs Maximum R ON. Isolation test voltage 3 V RMS Load voltage V Load current A DC configuration DIP- package
More informationOperating Manual UWAPS-TINY Series
Operating Manual UWAPS-TINY Series Powecon Oy WWW.POWECON.FI 1/9 Table of content 1 Warranty...3 2 Safety information...3 3 Abbreviations and terminology...3 4 List of appendices...4 5 Introduction...4
More information4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES
4 A CAPACITY, THE VARIETY OF CONTACT ARRANEMENTS S RELAYS FEATURES 28. 1.12 12..472 1.4.49 The variety of contact arrangements 2 Form A 2 Form B, 3 Form A 1 Form B, 4 Form A Latching types available High
More informationStandard Recovery Diodes (Hockey PUK), 2100 A
Standard Recovery Diodes (Hockey PUK), 2 A VS-SD10C..K Series DO-200AC (K-PUK) PRODUCT SUMMARY I F(AV) 2 A Package DO-200AC (K-PUK) Circuit configuration Single diode FEATURES Wide current range High voltage
More informationOptocoupler, Phototransistor Output, AC Input
Optocoupler, Phototransistor Output, AC Input DESCRIPTION The SFH62A (DIP) and SFH626 (SMD) feature a high current transfer ratio, low coupling capacitance and high isolation voltage. These couplers have
More informationMultifunction Digital Timer
Multifunction Digital Timer 1/16 DIN Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.
More informationStandard Recovery Diodes, (Stud Version), 40 A
Standard Recovery Diodes, (Stud ersion), 40 A S- FEATURES High surge current capability Stud cathode and stud anode version Leaded version available DO-203AB (DO-5) PRODUCT SUMMARY I F(A) 40 A Package
More informationNumber of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E
PCB Power elay The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of
More informationMINIATURE SURFACE MOUNT RELAY
FTR-K1 SERIES MINIATURE SURFACE MOUNT RELAY 1 POLE - 25A (For Automotive Applications) FTR-P6 Series FEATURES Surface mount relays for automotive applications Miniature size (67% of the volume of FTR-P3
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationCMOS Laser Sensor with Built-in Amplifier
New Product CMOS Laser Sensor with Built-in Amplifier ZX0 Stable Detection of Level Differences in the Order of 0.1 mm Dependable detection without being influenced by color, material, or surface conditions.
More information