How To Test A Water Pump

Size: px
Start display at page:

Download "How To Test A Water Pump"

Transcription

1 ph mv S ms O 2 Cl 2 ISE NTU Meinsberg Electrodes for Laboratory and Process

2 Instructions for using ph and redox combination electrodes Storage 1 ph and redox combination electrodes are stored in this medium which is filled in the reference system of the sensor. It is 3 mol/l or saturated KCl solution which is in the watering cap. ph and redox combination electrodes must never be stored in deionised water. Calibration 1 1. Rinse the sensor with deionised water. 2. Immerse the sensor in the buffer solution that the diaphragm is wetted completely. 3. Be sure that the sensor and the buffer have taken the same temperature value. 4. Rinse the sensor with deionised water before changing to the next buffer. Dispose the used buffer solution. Pay attention to the manual of the sensor and the measuring instrument. Cleaning 1 Clean diaphragm, glass membrane or platinum disc of the sensor with water and dap it dry with a paper towel. Oily and organic contamination: Protein contamination: Rinse the sensor with ethanol. Immerse the sensor in pepsin cleaning solution that the diaphragm is wetted completely. After cleaning rinse the sensor with deionised water and put it in its storage solution. Before the next measurement calibrating is necessary. Reconditioning 1 ph combination electrodes with decreasing slope and a slow response time can be reconditioned with a special solution. The glass membrane of the sensor is immersed for 2 minutes in maximum in the reconditioning solution. The diaphragm must never be wetted. After that the sensor is rinsed with deionised water and kept in its storage solution for 1 hour. Before the next measurement calibrating is necessary. 1 The order code for storage, buffer, cleaning and reconditioning solutions is printed on page 33.

3 Order key for reference electrodes and ph combination electrodes reference electrodes There is a plug head or a fixed cable with plug available. Please set your choice according to the following: SE/KE Example: SE 20 with 3 m special cable length, banana plug and screwable thread PG 13.5 = SE 20-SK030-H-P ph combination electrodes without temperature sensor - P = screwable thread PG 13.5 H = 4 mm banana plug F = stripped ends K = standard cable length 1 (additional setting of wished standard cable length, e. g. K010 for 1 m or K100 for 10 m) SK = special cable length (additional setting of wished special cable length, e. g. SK015 for 1.50 m or SK155 for m) L = S7 coaxial lab plug head Marking of basic type There is a plug head or a fixed cable with plug available for choice. Please set your choice according to the following: EG Example: EGA 151 with 3 m special cable length and BNC plug = EGA 151-SK030-B ph combination electrodes with temperature sensor P = screwable thread PG 13.5 B = BNC plug G = Cinch plug D = German DIN plug F = stripped ends K = standard cable length 1 (additional setting of wished standard cable length, e. g. K010 for 1 m or K100 for 10 m) SK = special cable length (additional setting of wished special cable length, e. g. SK015 for 1.50 m or SK155 for m) L = S7 coaxial lab plug head Continuation of the marking (e. g. 153) Marking of basic type (EGA/EGC) A = standard glass C = HT-glass (for strong alkaline mediums) There is a plug head or a fixed cable with plug available. Please set your choice according to the following: EG P = screwable thread PG 13.5 BH = BNC plug and 4 mm banana plug BG = BNC plug and Cinch plug BM = BNC plug and German MiniDIN plug DH = German DIN plug and 4 mm banana plug F = stripped ends K = standard cable length 1 (additional setting of wished standard cable length, e. g. K010 for 1 m or K100 for 10 m) SK = special cable length (additional setting of wished special cable length, e. g. SK015 for 1.50 m or SK155 for m) E = SMEK lab plug head 2 = with Pt 1000 Y = with Pt 100 Z30 = with NTC 30 kω Continuation of the marking (e. g. 143) Marking of basic type (EGA/EGC) A = standard glass C = HT-glass (for strong alkaline mediums) Example: EGA 143 with Pt 100,.50 m special cable length and stripped ends = EGA 143-Y-SK5-F 1 The following standard cable lengths are available: 1 m, 2 m, 5 m, 10 m and 15 m 2 SMEK is another description for SixPlug.

4 Order key for redox combination electrodes, conductivity cells, oxygen sensors redox(orp) combination electrodes There is a plug head or a fixed cable with plug available. Please set your choice according to the following: EMC Example: EMC 133 with 5 m standard cable length and German DIN plug = EMC 133-K050-D conductivity cells with temperature sensor P = screwable thread PG 13.5 B = BNC plug G = Cinch plug D = German DIN plug F = stripped ends K = standard cable length 1 (additional setting of wished standard cable length, e. g. K010 for 1 m or K100 for 10 m) SK = special cable length (additional setting of wished special cable length, e. g. SK015 for 1.50 m or SK155 for m) L = S7 coaxial lab plug head Marking of basic type There is a plug head or a fixed cable available. Please set your choice according to the following: LTG/LTC Example: LTG 1/23 with.50 m special cable length and stripped ends = LTG 1/23-SK5-F oxygen sensors with temperature sensor P = screwable thread PG 13.5 F = stripped ends K = standard cable length 1 (additional setting of wished standard cable length, e. g. K010 for 1 m or K100 for 10 m) SK = special cable length (additional setting of wished special cable length, e. g. SK015 for 1.50 m or SK155 for m) E = SMEK lab plug head 2 Marking of basic type There is a plug head or a fixed cable with plug available for choice. Please set your choice according to the following: MF Example: MF 41-N with 10 m standard cable length and multipin plug = MF 41-N-K100-U P = screwable thread PG 13.5 U = multipin plug (6 pins) F = stripped ends K = standard cable length 1 (additional setting of wished standard cable length, e. g. K010 for 1 m or K100 for 10 m) SK = special cable length (additional setting of wished special cable length, e. g. SK015 for 1.50 m or SK155 for m) E = SMEK lab plug head 2 Marking of basic type 1 The following standard cable lengths are available: 1 m, 2 m, 5 m, 10 m and 15 m 2 SMEK is another description for SixPlug.

5 Meinsberg electrodes for laboratory and process Electrochemical sensors are developed and manufactured in Meinsberg (Saxony/Germany) for more than 65 years. The innovative team of experienced chemists, design engineers, technicians and glassblowers realises high reliability, flexibility and quality. This catalogue presents our standard range of sensors for measuring ph value, redox potential, conductivity, dissolved oxygen, chlorine and temperature for application in laboratory and process. In the first part of the catalogue you find sensors for measuring in laboratory which are configured individually. These laboratory electrodes are available with plug or cable connection. Furthermore cable length and cable plug can be chosen. The order key for the different sensors (reference electrodes, ph and redox combination electrodes, conductivity cells and oxygen sensors) is illustrated in the folding book cover. In the second part of the catalogue you find sensors which are designed for online measurements in process. These process electrodes are always equipped with a plug connector with thread PG 13.5 for easy mounting in immersion or flow through housings. The order codes are shown in chapter process electrodes below the sensor pictures. On the following pages (2-5) the most important electrodes for laboratory and process with technical data and application advices are listed.

6 Content 1. Electrode selection table for application in laboratory and process Technical data of ph- and redox combination electrodes Electrodes for Laboratory Reference electrodes ph combination electrodes Redox combination electrodes Conductivity cells Oxygen sensors Connection cables for laboratory Electrodes for Process Temperature sensors ph glass electrodes and reference electrodes ph combination electrodes Redox combination electrodes Conductivity cells Oxygen sensors Chlorine sensors Turbidity- and suspended solids sensors Connection cables for process Electrical and process connection Standard Solutions and Electrolytes Temperature range of standard solutions, standard potentials of reference electrodes

7 1. Electrode selection table for application in laboratory and process (ph, redox, conductivity, oxygen and chlorine) aquariums aqueous solutions biotechnology (fermenter) cosmetics drinking water drinks electroplating field measurements high ph values low ionic mediums EGA 1 EGA 131 EGA 133 EGA 140 EGA 141 EGA 142 EGA 143 EGA 150 EGA 151 EGA 153 EGA 161 EGA 173 EGA 184 EGA 186 EGA 233 EGA 81 EGC 151 EGC 151 I/S EGP 150 EGV 150 OGA 201 EMC 133 EMC 173 EMC 30 EMC 33 LTC 0,35/23 LTC 1/23 LTG 0,1/23 LTG 1/23 LVV 0,1/23 MF 39 MF 39-T MF 41 CL 4 CS 2, CP 2 MCL 10 2

8 penetration measurements in chesse or meat penetration measurements in soil process chemistry sea water small volume samples soap water surfaces (e. g. paper) swimming pools temperature compensated measurements waste water/sewage water soluble lacquers page 8 8 8, , , , , 23 14, 24 14, ,

9 2. Technical data of ph- and redox combination electrodes All combination electrodes which are shown in the following table are equipped with a Ag/AgCl reference electrode. ph combination electrodes type shaft material shaft length (standard) in mm shaft diameter (mm) shaft diameter below (mm) temperature sensor membrane shape reference electrolyte (KCl concentration) EGA 1 glass 0 yes cylinder fluid (3 M) EGA 131 plastic 0 no ball fluid (3 M) EGA 133 plastic 0 no cylinder gel (3 M) EGA 140 glass 0 yes cylinder gel (3 M) EGA 141 glass 0 yes cylinder fluid (3 M) EGA 142 plastic 0 yes cylinder gel (3 M) EGA 143 glass 0 yes cylinder gel (3 M) EGA 150 glass 0 no cylinder gel (3 M) EGA 151 glass 0 no cylinder fluid (3 M) EGA 153 glass 0 no cylinder gel (3 M) EGA 161 glass 0 no cylinder fluid (3 M) EGA 173 glass 0 no cylinder gel (3 M) EGA 184 glass 0 6 no spear gel (3 M) EGA 186 glass no cylinder fluid (3 M) EGA 233 plastic 0 no cylinder gel (3 M) EGA 81 glass 0 no spear fluid (3 M) EGC 151 glass 0 no cylinder fluid (3 M) EGC 151 I/S glass 0 no cylinder fluid (saturated) EGP 150 glass 0 no cylinder gel (3 M) EGV 150 glass 0 no cylinder gel (3 M) OGA 201 glass 0 17 no flat fluid (3 M) redox combination electrodes type shaft material shaft length (standard) in mm shaft diameter (mm) metall electrode reference electrolyte (KCl concentration) EMC 133 plastic 0 platinum disc gel (3 M) EMC 173 glass 0 platinum disc gel (3 M) EMC 30 glass 0 platinum disc fluid (3 M) EMC 33 glass 0 platinum disc gel (3 M) 4

10 diaphragm number of diaphragms ph range temperature range ( C) pressure (bar) sample: minimum conductivity (µs/cm) minimum immersion depth (mm) page ceramic pressureless ceramic pressureless ceramic < , 19 ceramic < ceramic pressureless ceramic pressureless ring-shaped sleeve junction < ceramic < ceramic pressureless ceramic < flexible sleeve junction ring-shaped sleeve junction pressureless , < ceramic pressureless ceramic pressureless ceramic < ceramic pressureless ceramic pressureless ceramic pressureless ceramic < hole < ceramic pressureless diaphragm number of diaphragms measuring range (mv) temperature range ( C) pressure (bar) sample: minimum conductivity (µs/cm) minimum immersion depth (mm) page ceramic 2 ± < , 22 ring-shaped sleeve junction 1 ± < ceramic 1 ± < ceramic 1 ± < This sensor contains a KCl reserve pipe in the reference electrolyte. 5

11 3. Electrodes for Laboratory 3.1 Reference electrodes KE 10, KE 11 SE 10, SE 11 calomel electrode for measurements in very small volumes long-term stable (electrolyte with saturated KCl solution and KCl reserve) shaft diameter: 5 mm standard glass cone (NSK 7) is available for gas tight mounting in corrosion measuring cells with the according sleeve reference electrode with Ag/AgCl reference system for measurements in very small volumes long-term stable (electrolyte with saturated KCl solution and KCl reserve) shaft diameter: 5 mm easy cleaning by removing the sleeve connector standard glass cone (NSK 7) is available for gas tight mounting in corrosion measuring cells with the according sleeve KE 11 SE 10 NSK 7 Technical Data: Type KE 10 KE 11 SE 10 SE 11 Shaft glass, Ø /5 mm glass, Ø /5 mm glass, Ø /5 mm glass, Ø /5 mm Shaft length 155 mm 155 mm 155 mm 155 mm Reference system calomel calomel Ag/AgCl Ag/AgCl Electrolyte (KCl) fluid (saturated) with fluid (saturated) with fluid (saturated) with fluid (saturated) with KCl reserve KCl reserve KCl reserve KCl reserve Bridge electrolyte Diaphragm sleeve junction 1 x ceramic sleeve junction 1 x ceramic Temperature range C C C C Minimum 10 mm 10 mm 10 mm 10 mm immersion depth Application small volume sample, aqueous solutions small volume sample, aqueous solutions small volume sample, aqueous solutions small volume sample, aqueous solutions Electrical connection 4 mm banana socket 4 mm banana socket 4 mm banana socket 4 mm banana socket Order code/ Order key KE 10, KE 10 NSK-7 KE 11, KE 11 NSK-7 SE 10, SE 10 NSK-7 SE 11, SE 11 NSK-7 6

12 SE 20, SE 21 SE 20 EB, SE 21 EB reference electrode with Ag/AgCl reference system for measurements in connection with ion-selective electrodes long-term stable (electrolyte with saturated KCl solution and KCl reserve) shaft diameter: mm reference electrode with Ag/AgCl double-junction reference system for measurements in critical mediums measurements in connection with ion-selective electrodes long-term stable (electrolyte with saturated KCl solution and KCl reserve) the bridge electrolyte is defined by the customer SE 21-L SE 20 EB-L SE 20 SE 21 SE 20 EB SE 21 EB glass, Ø mm glass, Ø mm glass, Ø mm glass, Ø mm 0 mm 0 mm 160 mm 160 mm Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgCl fluid (saturated) with fluid (saturated) with fluid (saturated) with fluid (saturated) with KCl reserve KCl reserve KCl reserve KCl reserve - - customer request customer request flexible sleeve junction 1 x ceramic flexible sleeve junction (outside), 2 x ceramic (inside), (double junction reference system) C C C C 20 mm 10 mm 20 mm 10 mm 1 x ceramic (outside) 2 x ceramic (inside), (double junction reference system) polluted or low ionic mediums aqueous solutions polluted mediums, strong acids and bases critical mediums (strong acids and bases) S7 coaxial lab plug head, fixed cable S7 coaxial lab plug head, fixed cable S7 coaxial lab plug head, fixed cable S7 coaxial lab plug head, fixed cable Refer to the left book cover! Refer to the left book cover! Refer to the left book cover! Refer to the left book cover! All electrodes can be configured according to plug connector, cable length, plug and thread PG 13.5 (Refer to the left book cover!). The connection cable for the S7 coaxial lab plug head is illustrated on page 16. 7

13 3.2 ph combination electrodes EGA 131 EGA 133 EGA 1 ph combination electrode for swimming pool and aquarium water robust plastic shaft with integrated ph membrane protection refillable electrolyte ph combination electrode for swimming pool and aquarium water robust plastic shaft with integrated ph membrane protection gel electrolyte ph combination electrode for pocket meters integrated temperature sensor refillable electrolyte robust plastic shaft with integrated ph membrane protection EGA 131-L EGA 133-L EGA 1--E Technical Data: Type EGA 131 EGA 133 EGA 1 Shaft plastic, Ø mm plastic, Ø mm plastic, Ø mm Shaft length 0 mm 0 mm 0 mm Temperature sensor - - Pt 1000 or Pt 100 or NTC 30 kω Membrane shape ball cylinder cylinder Reference system Ag/AgCl Ag/AgCl Ag/AgCl Electrolyte (KCl) fluid (3 M) gel (3 M) fluid (3 M) Diaphragm 2 x ceramic 2 x ceramic 1 x ceramic Isopotential point 7.0 ± ± ± 0.3 ph range Temperature range C C C Minimum immersion depth 15 mm 15 mm 15 mm Application field measurements, aquarium water, surface water, swimming pools field measurements, aquarium water, surface water, swimming pools field measurements, aquarium water,surface water, swimming pools, waste water, environmental analysis SMEK lab plug head, fixed cable Electrical connection S7 coaxial lab plug head, S7 coaxial lab plug head, fixed cable fixed cable Order key Refer to the left book cover! Refer to the left book cover! Refer to the left book cover! All electrodes can be configured according to plug connector, cable length, plug and thread PG 13.5 (Refer to the left book cover!). The connection cable for the S7 coaxial lab plug head is illustrated on page 16. The connection cable for the SMEK lab plug head is illustrated on page 16 and 30. 8

14 EGA 141 EGA 142 EGA 161 ph combination electrode for pocket meters integrated temperature sensor refillable electrolyte glass shaft can be cleaned very well ph combination electrode for pocket meters integrated temperature sensor low maintenance robust plastic shaft with integrated ph membrane protection ph combination electrode for measurements in low ionic mediums and cosmetics refillable electrolyte flexible sleeve junction EGA 141--E EGA 142--E EGA 161-L EGA 141 EGA 142 EGA 161 glass, Ø mm plastic, Ø mm glass, Ø mm 0 mm 0 mm 0 mm Pt 1000 or Pt 100 or Pt 1000 or Pt 100 or - NTC 30 kω NTC 30 kω cylinder cylinder cylinder Ag/AgCl Ag/AgCl Ag/AgCl fluid (3 M) gel (3 M) fluid (3 M) 2 x ceramic 2 x ceramic flexible sleeve junction 7.0 ± ± ± C C C 22 mm 15 mm 32 mm aquarium water, surface water, swimming pools, waste water, environmental analysis field measurements, aquarium water, surface water, swimming pools, waste water, environmental analysis low ionic mediums, cosmetics SMEK lab plug head, fixed cable SMEK lab plug head, fixed cable S7 coaxial lab plug head, fixed cable Refer to the left book cover! Refer to the left book cover! Refer to the left book cover! The ph combination electrode EGA 141 is also available with HT-glass (EGC 141). EGC 141 can be used in hot (100 C) mediums with extreme ph values. All electrodes can be configured according to plug connector, cable length, plug and thread PG 13.5 (Refer to the left book cover!). The connection cable for the S7 coaxial lab plug head is illustrated on page 16. The connection cable for the SMEK lab plug head is illustrated on page 16 and 30. 9

15 EGA 151, EGC 151 OGA 201 EGA 151: ph combination electrode for general application in laboratory and beverage industry refillable electrolyte glass shaft can be cleaned very well ph combination electrode for measurements on surfaces, e. g. paper flat membrane EGC 151: ph combination electrode for measurements in hot (100 C) mediums with extreme ph values refillable electrolyte glass shaft can be cleaned very well EGA 151-L OGA 201-L Technical Data: Type EGA 151 EGC 151 OGA 201 Shaft glass, Ø mm glass, Ø mm glass, Ø mm Shaft length 0 mm 0 mm 0 mm Temperature sensor Membrane shape cylinder cylinder flat Reference system Ag/AgCl Ag/AgCl Ag/AgCl Electrolyte (KCl) fluid (3 M) fluid (3 M) fluid (3 M) Diaphragm 1 x ceramic 1 x ceramic 1 x ceramic Isopotential point 7.0 ± ± ± 0.3 ph range Temperature range C C C Minimum immersion depth 22 mm 22 mm 2 mm Application aquarium water, beverages, environmental analysis hot (100 C) mediums with extreme ph values ph measurements on surfaces, e. g. paper Electrical connection Order key S7 coaxial lab plug head, fixed cable Refer to the left book cover! S7 coaxial lab plug head, fixed cable Refer to the left book cover! S7 coaxial lab plug head, fixed cable Refer to the left book cover! All electrodes can be configured according to plug connector, cable length and plug (Refer to the left book cover!). The OGA 201 can not be equipped with thread PG 13.5 (P). The connection cable for the S7 coaxial lab plug head is illustrated on page

16 EGA 81 EGA 184 EGA 186 ph combination electrode for penetration measurements in soil spear membrane ph combination electrode for penetration measurements in meat and cheese internal gel electrolyte (a measurement is possible in every position) spear membrane ph combination electrode for measurements in small volumes shaft diameter: 6 mm refillable electrolyte EGA 81-L EGA 184-L EGA 186-L EGA 81 EGA 184 EGA 186 glass, Ø mm glass, Ø /6 mm glass, Ø /6 mm 0 mm 0 mm 170 mm spear spear cylinder Ag/AgCl Ag/AgCl Ag/AgCl fluid (3 M) gel (3 M) fluid (3 M) 3 x ceramic 2 x ceramic 2 x ceramic 7.0 ± ± ± C C C 22 mm 15 mm 15 mm viscous mediums, samples of soil penetration measurements in food small volume samples S7 coaxial lab plug head, fixed cable S7 coaxial lab plug head, fixed cable S7 coaxial lab plug head, fixed cable Refer to the left book cover! Refer to the left book cover! Refer to the left book cover! All electrodes can be configured according to plug connector, cable length and plug (Refer to the left book cover!). The connection cable for the S7 coaxial lab plug head is illustrated on page

17 3.3 Redox combination electrodes EMC 133 EMC 30 redox combination electrode for swimming pool and aquarium water mechanical stable platinum disc robust plastic shaft with integrated sensor protection redox combination electrode for general application in laboratory and soap water mechanical stable platinum disc refillable electrolyte glass shaft can be cleaned very well EMC 133-L EMC 30-L Technical Data: Type EMC 133 EMC 30 Shaft plastic, Ø mm glass, Ø mm Shaft length 0 mm 0 mm Measuring electrode platinum disc Ø 5 mm platinum disc Ø 5 mm Reference system Ag/AgCl Ag/AgCl Electrolyte (KCl) gel (3 M) fluid (3 M) Diaphragm 2 x ceramic 1 x ceramic Measuring range ± 2000 mv ± 2000 mv Temperature range C C Minimum immersion depth 15 mm mm Application field measurements, aquarium water, surface water, swimming pools raw water, soap water, environmental analysis Electrical connection S7 coaxial lab plug head, fixed cable S7 coaxial lab plug head, fixed cable Order key Refer to the right book cover! Refer to the right book cover! All electrodes can be configured according to plug connector, cable length, plug and thread PG 13.5 (Refer to the right book cover!). The connection cable for the S7 coaxial lab plug head is illustrated on page 16.

18 3.4 Conductivity cells LTC 0,35/23 LTC 1/22 or LTC 1/23 conductivity cell for pocket meters 4-electrode technology wide measuring range: 5 µs/cm 500 ms/cm integrated temperature sensor robust plastic shaft conductivity cell for pocket meters and aquaristics 2-electrode technology robust plastic shaft graphite electrodes can be cleaned very well integrated temperature sensor LTC 0,35/23-E LTC 1/23-E Technical Data: Type LTC 0,35/23 LTC 1/22 or LTC 1/23 Shaft plastic, Ø mm plastic, Ø mm Shaft length 0 mm 0 mm Electrode material graphite graphite Temperature sensor Pt 1000 LTC 1/22: Pt 100 LTC 1/23: Pt 1000 Measuring principle 4-electrode technology 2-electrode technology Cell constant 0.33 cm -1 ± 5 % 1 cm -1 ± 20 % Measuring range 5 µs/cm 500 ms/cm 10 µs/cm 20 ms/cm Temperature range C C Minimum mmersion depth 20 mm 15 mm Application drinking water, surface water, waste water, sea water, industrial process water, acids, bases drinking water, surface water, waste water, sea water Electrical connection SMEK lab plug head, fixed cable SMEK lab plug head, fixed cable Order key Refer to the right book cover! Refer to the right book cover! All electrodes can be configured according to plug connector, cable length and thread PG 13.5 (Refer to the right book cover!). The connection cable for the SMEK lab plug head is illustrated on page 16 and

19 LTG 0,1/22 or LTG 0,1/23 LTG 1/22 or LTG 1/23 conductivity cell for measurements in low ionic mediums e. g. distilled water 2-electrode technology low conductivity values: 1 µs/cm 200 µs/cm long-term stable platinum electrodes integrated temperature sensor conductivity cell for measurements in swimming pools and beverage industry 2-electrode technology wide measuring range: 10 µs/cm 20 ms/cm long-term stable platinum electrodes realise measurements in critical mediums integrated temperature sensor LTG 0,1/23-E LTG 1/23-E Technical Data: Type LTG 0,1/22 or LTG 0,1/23 LTG 1/22 or LTG 1/23 Shaft glass, Ø mm glass, Ø mm Shaft length 0 mm 0 mm Electrode material platinum (8x17 mm) platinum (3x4 mm) Temperature sensor LTG 0,1/22: Pt 100 LTG 1/22: Pt 100 LTG 0,1/23: Pt 1000 LTG 1/23: Pt 1000 Measuring principle 2-electrode technology 2-electrode technology Cell constant 0.1 cm -1 ± 20 % 1 cm -1 ± 20 % Measuring range 1 µs/cm 200 µs/cm 10 µs/cm 20 ms/cm Temperature range C C Minimum immersion depth 35 mm 25 mm Application low ionic mediums (distillation plants, ion exchanger) drinking water, surface water, waste water, sea water, swimming pools, beverages Electrical connection SMEK lab plug head, fixed cable SMEK lab plug head, fixed cable Order key Refer to the right book cover! Refer to the right book cover! All electrodes can be configured according to plug connector, cable length and thread PG 13.5 (Refer to the right book cover!). The connection cable for the SMEK lab plug head is illustrated on page 16 and

20 3.5 Oxygen sensors MF 41-N oxygen sensor for measurements in aqueous solutions in connection with pocket meters corrosion-resistant for application in sea water integrated temperature sensor for temperature compensation robust plastic shaft membrane head is changeable Technical Data: MF 41-N-E Type MF 41-N Shaft plastic, Ø mm Shaft length 0 mm Cathode platinum Anode Ag/AgCl Temperature sensor Pt 1000 Measuring principle amperometric (Clark) Signal in air na Response time in N 2 t 90 < 30 s Flow rate > 9 cm/s Measuring range 0 20 mg/l, % air saturation Temperature range C Minimum 30 mm immersion depth Application field measurements, aquarium water, surface water, sea water Electrical connection Order key SMEK lab plug head, fixed cable Refer to the right book cover! All electrodes can be configured according to plug connector, cable length and thread PG 13.5 (Refer to the right book cover!). The connection cable for the SMEK lab plug head is illustrated on page 16 and

21 3.6 Connection cables for laboratory The following standard cable lengths are available: 1 m, 2 m, 5 m, 10 m and 15 m Special cable lengths are possible. order code cable 1. cable end 2. cable end sensors Koax 3 Ø 3 mm, coax S7 cable socket German DIN plug ph combination electrode, redox combination electrode Koax 4 Ø 3 mm, coax S7 cable socket 4 mm banana plug reference electrode Koax 5 Koax 6 Ø 3 mm, coax Ø 5 mm, coax S7 cable socket BNC plug ph combination electrode, redox combination electrode, 2-electrode conductivity cell, oxygen sensor S7 cable socket 2 x 4 mm banana plug 2-electrode conductivity cell, temperature sensor Koax 7 Ø 3 mm, coax S7 cable socket Cinch plug ph combination electrode, redox combination electrode Koax 9 Ø 5 mm, 1 shield, 1 coax, 4 wires SMEK socket BNC plug, 2 x 4 mm banana plug ph combination electrode with temperature sensor (e. g. for LM 2000) Koax 10 Ø 5 mm, 1 shield, 6 wires SMEK socket BNC plug, 2 x 4 mm banana plug oxygen sensor with temperature sensor (e. g. for LM 2000) Koax 11 Ø 5 mm, 1 shield, 6 wires SMEK socket BNC plug, 2 x 4 mm banana plug 2-electrode conductivity cell with temperature sensor (e. g. for LM 2000) Example: measuring cable Koax 3 with 1 m standard cable length = Koax 3/1 SMEK is another description for SixPlug. 16

22 4. Electrodes for Process 4.1 Temperature sensors Pt 100 I, Pt 1000 I platinum temperature sensor in accordance with DIN EN 60751, class A long-term stable glass shaft can be cleaned very well for temperature compensation of electrochemical parameters Technical Data: Pt 1000 I Type Pt 100 I Pt 1000 I Shaft glass, Ø mm glass, Ø mm Immersion length 0 mm 0 mm Temperature sensor Pt 100 platinum temperature sensor in accordance with DIN EN 60751, class A Pt 1000 platinum temperature sensor in accordance with DIN EN 60751, class A Temperature range C C Pressure < 6 bar < 6 bar Application fluids fluids Electrical connection S7 coaxial plug head with thread PG 13.5 S7 coaxial plug head with thread PG 13.5 Order code Pt 100 I Pt 1000 I The connection cable for the S7 coaxial plug head with thread PG 13.5 is illustrated on page

23 4.2 ph glass electrodes and reference electrodes GA 151 I SE 23 I ph glass electrode for measurements in aqueous solutions measuring in connection with the reference electrode SE 23 I reference electrode for measurements in aqueous solutions measuring in connection with the ph glass electrode GA 151 I or with ionselective electrodes gel electrolyte and 3 KCl reserve pipes low maintenance GA 151 I SE 23 I Technical Data: Type GA 151 I SE 23 I Shaft glass, Ø mm glass, Ø mm Immersion length 0 mm 0 mm Temperature sensor - - Membrane shape cylinder - Reference system - Ag/AgCl Electrolyte (KCl) - gel (3 M) Diaphragm - 3 x ceramic Isopotential point 7.0 ± ph range Temperature range C C Pressure < 6 bar < 6 bar Minimum conductivity µs/cm of the medium Application aqueous solutions aqueous solutions Electrical connection S7 coaxial plug head with thread PG 13.5 S7 coaxial plug head with thread PG 13.5 Order code GA 151 I SE 23 I The connection cable for the S7 coaxial plug head with thread PG 13.5 is illustrated on page

24 4.3 ph combination electrodes EGA 133 I EGA 233 I EGA 140 EGA 143 ph combination electrode for swimming pool and aquarium water robust plastic shaft with integrated ph membrane protection gel electrolyte ph combination electrode for measurements in so called electrode toxins (sulphides) double-junction reference system gel electrolyte ph combination electrode for beverage industry integrated temperature sensor gel electrolyte ph combination electrode for heavily polluted waste water ring-shaped sleeve junction integrated temperature sensor gel electrolyte EGA 133 I EGA 233 I EGA 140 SMEK- EGA 143 SMEK- EGA 133 I EGA 233 I EGA 140 EGA 143 plastic, Ø mm plastic, Ø mm glass, Ø mm glass, Ø mm 0 mm 0 mm 0 mm 0 mm - - Pt 1000 or Pt 100 or NTC 30 kω Pt 1000 or Pt 100 or NTC 30 kω cylinder cylinder cylinder cylinder Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgCl gel (3 M) gel (3 M) gel (3 M) gel (3 M) 2 x ceramic 4 x ceramic 2 x ceramic ring-shaped sleeve junction 7.0 ± ± ± ± C C C C < 6 bar < 6 bar < 6 bar < 6 bar 100 µs/cm 100 µs/cm 100 µs/cm 50 µs/cm raw water, waste water, surface water, swimming pools S7 coaxial plug head with thread PG 13.5 waste water, electroplating, mediums in so called electrode toxins S7 coaxial plug head with thread PG 13.5 surface water, soap water, beverages SMEK plug head with thread PG 13.5 or Variopin plug head with thread PG 13.5 EGA 133 I EGA 233 I EGA 140 SMEK EGA 140 VP EGC 140 SMEK EGC 140 VP heavily polluted waste water, electroplating SMEK plug head with thread PG 13.5 or Variopin plug head with thread PG 13.5 EGA 143 SMEK EGA 143 VP EGC 143 SMEK EGC 143 VP The ph combination electrodes EGA 140 and EGA 143 are also available with HT-glass (EGC 140 and EGC 143). EGC 140 and EGC 143 can be used in hot (100 C) mediums with extreme ph values. The connection cables for the plug connectors (S7 coaxial plug head with thread PG 13.5, SMEK plug head with thread PG 13.5 or Variopin plug head with thread PG 13.5) are illustrated on page

25 EGA 150 I EGC 151 I/S EGA 153 I ph combination electrode for swimming pool and aquarium water gel electrolyte ph combination electrode for pressureless application in process chemistry (sugar industry) thermally stable up to 100 C long-term stable (electrolyte with saturated KCl solution and KCl reserve) ph combination electrode for waste water and electroplating 3 ceramic diaphragms gel electrolyte with KCl reserve pipe EGA 150 I EGC 151 I/S EGA 153 I Technical Data: Type EGA 150 I EGC 151 I/S EGA 153 I Shaft glass, Ø mm glass, Ø mm glass, Ø mm Immersion length 0 mm 0 mm 0 mm Temperature sensor Membrane shape cylinder cylinder cylinder Reference system Ag/AgCl Ag/AgCl Ag/AgCl Electrolyte (KCl) gel (3 M) fluid (saturated) with gel (3 M) KCl reserve Diaphragm 1 x ceramic 1 x ceramic 3 x ceramic Isopotential point 7.0 ± ± ± 0.3 ph range Temperature range C C C Pressure < 6 bar pressureless < 6 bar Minimum conductivity of the medium Application 100 µs/cm 100 µs/cm 100 µs/cm raw water, waste water, surface water, swimming pools hot (100 C) mediums with extreme ph values heavily waste water, electroplating Electrical connection S7 coaxial plug head with thread PG 13.5 S7 coaxial plug head with thread PG 13.5 S7 coaxial plug head with thread PG 13.5 Order code EGA 150 I EGC 150 I EGC 151 I/S EGA 151 I/S EGA 153 I EGC 153 I The ph combination electrodes EGA 150 and EGA 153 are also available with HT-glass (EGC 150 and EGC 153). EGC 150 and EGC 153 can be used in hot (100 C) mediums with extreme ph values. The ph combination electrode EGC 151 I/S is also available with standard glass (EGA 151 I/S). EGA 151 I/S can be used in low ionic mediums. The connection cable for the S7 coaxial plug head with thread PG 13.5 is illustrated on page

26 EGP 150 I EGV 150 I EGA 161 L/PG EGA 173 I ph combination electrode for measurements in process chemistry thermally stable up to 130 C gel electrolyte ph combination electrode for sterilisations in biotechnology thermally stable up to 130 C gel electrolyte ph combination electrode for low ionic mediums side tube realises connecting to an electrolyte reservoir constant outflow of electrolyte flexible sleeve junction ph combination electrode for heavily polluted waste water and electroplating ring-shaped sleeve junction gel electrolyte with KCl reserve pipe EGP 150 I EGV 150 I EGA 161 L/PG EGA 173 I EGP 150 I EGV 150 I EGA 161 L/PG EGA 173 I glass, Ø mm glass, Ø mm glass, Ø mm glass, Ø mm 0 mm 0 mm 0 mm 0 mm cylinder cylinder cylinder cylinder Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgCl gel (3 M) gel (3 M) fluid (3 M) gel (3 M) 3 x ceramic 2 x holes flexible sleeve junction sleeve junction 7.0 ± ± ± ± C C C C < 15 bar < 6 bar < 1 bar with pressure load at < 6 bar side tube connector 100 µs/cm 50 µs/cm 20 µs/cm 50 µs/cm process chemistry, high temperatures S7 coaxial plug head with thread PG 13.5 biotechnology, fermenters S7 coaxial plug head with thread PG 13.5 low ionic mediums, drinking water with low conductivity S7 coaxial lab plug head with thread PG 13.5 (shaft) drinking water, water soluble lacquers, electroplating, waste water S7 coaxial plug head with thread PG 13.5 EGP 150 I EGV 150 I EGA 161 L/PG EGA 173 I EGC 173 I The ph combination electrode EGA 173 is also available with HT-glass (EGC 173). EGC 173 can be used for hot (100 C) mediums and extreme ph values. The connection cables for the plug connectors (S7 coaxial lab plug head, S7 coaxial plug head with thread PG 13.5) are illustrated on page

27 4.4 Redox combination electrodes EMC 133 I EMC 173 I EMC 33 I redox combination electrode for swimming pool and aquarium water mechanical stable platinum disc robust plastic shaft with integrated sensor protection gel electrolyte redox combination electrode for waste water and electroplating mechanical stable platinum disc ring-shaped sleeve junction gel electrolyte with KCl reserve pipe redox combination electrode for swimming pool and fish farming mechanical stable platinum disc gel electrolyte EMC 133 I EMC 173 I EMC 33 I Technical Data: Type EMC 133 I EMC 173 I EMC 33 I Shaft plastic, Ø mm glass, Ø mm glass, Ø mm Immersion length 0 mm 0 mm 0 mm Measuring electrode platinum disc Ø 5 mm platinum disc Ø 5 mm platinum disc Ø 5 mm Reference system Ag/AgCl Ag/AgCl Ag/AgCl Electrolyte (KCl) gel (3 M) gel (3 M) gel (3 M) Diaphragm 2 x ceramic sleeve junction 1 x ceramic Measuring range ± 2000 mv ± 2000 mv ± 2000 mv Temperature range C C C Pressure < 6 bar < 6 bar < 6 bar Minimum conductivity 100 µs/cm 50 µs/cm 100 µs/cm of the medium Application raw water, waste water, surface water, swimming pools drinking water, water soluble lacquers, electroplating, waste water raw water, waste water, surface water, swimming pools Electrical connection S7 coaxial plug head S7 coaxial plug head S7 coaxial plug head with thread PG 13.5 with thread PG 13.5 with thread PG 13.5 Order code EMC 133 I EMC 173 I EMC 33 I The connection cable for the S7 coaxial plug head with thread PG 13.5 is illustrated on page

28 4.5 Conductivity cells LTC 0,35/23 LTG 0,1/22 or LTG 0,1/23 conductivity cell for waste and sea water 4-electrode technology wide measuring range: 5 µs/cm 500 ms/cm robust plastic shaft conductivity cell for measurements in low ionic mediums e. g. distilled water 2-electrode technology low conductivity values: 1 µs/cm 200 µs/cm long-term stable platinum electrodes integrated temperature sensor LTC 0,35/23 SMEK LTG 0,1/23 SMEK Technical Data: Type LTC 0,35/23 LTG 0,1/22 or LTG 0,1/23 Shaft plastic, Ø mm glass, Ø mm Immersion length 0 mm 0 mm Electrode material graphite platinum (8x17 mm) Temperature sensor Pt 1000 LTG 0,1/22: Pt 100 LTG 0,1/23: Pt 1000 Measuring principle 4-electrode technology 2-electrode technology Cell constant 0.33 cm -1 ± 5 % 0.1 cm -1 ± 20 % Measuring range 5 µs/cm 500 ms/cm 1 µs/cm 200 µs/cm Temperature range C C Pressure < 6 bar < 6 bar Application waste water, sea water, industrial process water, acids, bases low ionic mediums (distillation plants, ion exchanger) Electrical connection SMEK plug head with thread PG 13.5 or Variopin plug head with thread PG 13.5 SMEK plug head with thread PG 13.5 or Variopin plug head with thread PG 13.5 Order code LTC 0,35/23 SMEK LTC 0,35/23 VP LTG 0,1/22 SMEK LTG 0,1/22 VP LTG 0,1/23 SMEK LTG 0,1/23 VP The connection cables for the plug connectors (SMEK plug head with thread PG 13.5 or Variopin plug head with thread PG 13.5) are illustrated on page

29 LTG 1/22 or LTG 1/23 LVV 0,1/23 conductivity cell for measurements in swimming pools and beverage industry 2-electrode technology wide measuring range: 10 µs/cm 20 ms/cm long-term stable platinum electrodes realise measurements in critical mediums integrated temperature sensor robust stainless steel conductivity cell for industrial application measurements in low ionic mediums e. g. distilled water 2-electrode technology low conductivity values: 1 µs/cm 200 µs/cm integrated temperature sensor LTG 1/23 SMEK LVV 0,1/23 SMEK LVV 0,1/23 SMEK-S Technical Data: Type LTG 1/22 or LTG 1/23 LVV 0,1/23 Shaft glass, Ø mm stainless steel, Ø mm Immersion length 0 mm 0 mm Electrode material platinum (3x4 mm) stainless steel Temperature sensor LTG 1/22: Pt 100 Pt 1000 LTG 1/23: Pt 1000 Measuring principle 2-electrode technology 2-electrode technology Cell constant 1 cm -1 ± 20 % 0.1 cm -1 ± 20 % Measuring range 10 µs/cm 20 ms/cm 1 µs/cm 200 µs/cm Temperature range C C Pressure < 6 bar < 6 bar Application drinking water, surface water, waste water, sea water low ionic mediums (distillation plants, ion exchanger) Electrical connection SMEK plug head with thread PG 13.5 or Variopin plug head with thread PG 13.5 SMEK plug head with thread PG 13.5 or Variopin plug head with thread PG 13.5 Order code LTG 1/22 SMEK LTG 1/22 VP LTG 1/23 SMEK LTG 1/23 VP LVV 0,1/23 SMEK LVV 0,1/23 VP The connection cables for the plug connectors (SMEK plug head with thread PG 13.5 or Variopin plug head with thread PG 13.5) are illustrated on page

30 4.6 Oxygen sensors MF 39, MF 39-T MF 41-N SMEK MF 39: oxygen sensor for waste water integrated temperature sensor robust plastic shaft membrane head is changeable oxygen sensor for fish farming in fresh water and sea water corrosion-resistant integrated temperature sensor robust plastic shaft membrane head is changeable MF 39-T: oxygen sensor for sea water and process chemistry corrosion-resistant because of titanium design integrated temperature sensor robust plastic shaft membrane head is changeable MF 39 SMEK MF 41-N SMEK Technical Data: Type MF 39 MF 39-T MF 41-N SMEK Shaft plastic, stainless steel, Ø 18 mm plastic, titanium, Ø 18 mm plastic, Ø mm Immersion length 0 mm 0 mm 0 mm Cathode platinum platinum platinum Anode Ag/AgCl Ag/AgCl Ag/AgCl Temperature sensor Pt 1000 Pt 1000 Pt 1000 Measuring principle amperometric (Clark) amperometric (Clark) amperometric (Clark) Signal in air na na na Response time in N 2 t 90 < 70 s t 90 < 70 s t 90 < 30 s Flow rate > 9 cm/s > 9 cm/s > 9 cm/s Measuring range 0 60 mg/l, % 0 60 mg/l, % 0 20 mg/l, % air saturation air saturation air saturation Temperature range C C C Pressure < 3 bar < 3 bar < 1 bar Application Electrical connection Order code/ Order key drinking water, aquarium water, surface water, waste water SMEK lab plug head with thread PG 16 or Variopin plug head with thread PG 16 MF 39 SMEK MF 39 VP sea water, corrosive mediums SMEK lab plug head with thread PG 16 or Variopin plug head with thread PG 16 MF 39-T SMEK MF 39-T VP aquarium water, surface water, sea water SMEK plug head with thread PG 13.5 MF 41-N SMEK The connection cables for the plug connectors (SMEK lab plug head, Variopin plug head and SMEK plug head with thread PG 13.5) are illustrated on page

31 MF 441 oxygen sensor for composting plants integrated temperature sensor design in stainless steel membrane head is changeable MF 441-K010-F Technical Data: Type MF 441 Shaft stainless steel, Ø 18 mm Immersion length shaft length: 105 mm Cathode platinum Anode Ag/AgCl Temperature sensor Pt 1000 Measuring principle amperometric (Clark) Signal in air na Response time in N 2 t 90 < 180 s Flow rate - Measuring range 0 20 mg/l, % air saturation Temperature range C Pressure < 1 bar Application oxygen measurements in composting plants Electrical connection Order code/ Order key fixed cable Refer to the right book cover! The oxygen sensor MF 441 can be configured according to cable length and plug (Refer to the right book cover!). The MF 441 can not be equipped with SMEK lab plug head (E) and thread PG 13.5 (P). 26

32 4.7 Chlorine sensors MCL 10 I CL 4 chlorine sensor for swimming pool and drinking water treatment free chlorine shaft diameter: mm system depends on ph value and temperature chlorine sensor for swimming pool and drinking water treatment free chlorine system depends on ph value MCL 10 I CL 4 Technical Data: Type MCL 10 I CL 4 Shaft plastic, Ø mm plastic, Ø 25 mm Immersion length 0 mm 0 mm Measuring principle amperometric 2-electrode system amperometric 2-electrode system Measuring range 0 2 mg/l 0 2 mg/l ph range ph 6 8 ph 6 8 ph dependency in correlation with the dissociation curve of HOCl in correlation with the dissociation curve of HOCl; ph recommended Flow rate 50 l/h recommended 30 l/h recommended Temperature range 0 30 C 0 45 C (temperature compensated) Pressure < 1 bar < 1 bar Application swimming pools, drinking water, sea and process water swimming pools, drinking water, sea and process water Electrical connection S7 coaxial plug head with thread PG 13.5 CL 4: 4-20 ma, 2-wire connection CL 4-R: -100 mv per mg/l, 4-pin plug connection Order code MCL 10 I CL 4 CL 4-R The connection cables for chlorine sensors are illustrated on page

33 CS 2, CP 2 CS 2: chlorine sensor for swimming pool and drinking water treatment free chlorine system with very low ph dependency CP 2: chlorine sensor for swimming pool and drinking water treatment total chlorine system with very low ph dependency CS 2 Technical Data: Type CS 2 CP 2 Shaft plastic, stainless steel, Ø 25 mm plastic, stainless steel, Ø 25 mm Immersion length 0 mm 0 mm Measuring principle amperometric working potentiostatic 3-electrode system Measuring range 0 2 mg/l 0 2 mg/l ph range ph 4 ph 4 amperometric working potentiostatic 3-electrode system ph dependency about 10 % slope reduction per ph unit about 10 % slope reduction per ph unit Flow rate 30 l/h recommended 30 l/h recommended Temperature range 0 45 C (temperature compensated) 0 45 C (temperature compensated) Pressure < 0.5 bar < 0.5 bar Application swimming pools, drinking and process water Electrical connection CS 2: 4-20 ma, 2-wire connection CS 2-R: -100 mv per mg/l, 4-pin plug connection Order code CS 2 CS 2-R swimming pools, drinking and process water CP 2: 4-20 ma, 2-wire connection CP 2-R: -100 mv per mg/l, 4-pin plug connection CP 2 CP 2-R The connection cables for chlorine sensors are illustrated on page 30. Other measuring ranges on request. 28

34 4.8 Turbidity- and suspended solids sensors SAM-T, SSN-T SAM-T: submersible suspended solid probe for measurements in suspensions and sludges infrared absorption measurement SSN-T: submersible turbidity probe for measurements in dirty water up to 1000 NTU infrared scattered-light measurement at ISO 7027/EN Technical Data: SSN-T Type SAM-T SSN-T Shaft stainless steel, sensor window epoxy resin, Ø 38 mm stainless steel, sensor window POM, Ø 38 mm Shaft length 146 mm, screw mounted cap R 1" 137 mm, screw mounted cap R 1" Optical components light absorption method with four-beam pulsed light method, infrared light, wavelength 880 nm (absorption maximum) 90 scattered light measurement with pulsed infrared light, wavelength 880 nm, multi-beam pulsed light evaluation Measuring range FNU/NTU FNU/NTU Temperature range 0 50 C 0 50 C Pressure < 6 bar < 6 bar Application waste water, raw water, suspensions, sludges river water, boiler water, purified waste water, surface water, raw and drinking water Electrical connection 13 m fixed cable with multipin plug, IP m fixed cable with multipin plug, IP 68 Order code SAM-T SSN-T 29

35 4.9 Connection cables for process The following standard cable lengths are available: 1 m, 2 m, 5 m, 10 m and 15 m Special cable lengths are possible. Cables for process (coaxial cable) order code cable 1. cable end 2. cable end sensors K 43 Ø 5 mm, coax S7 cable socket stripped ends ph combination electrode, redox combination electrode, 2-electrode conductivity cell, oxygen sensor, temperature sensor K 43-Pt Ø 5 mm, coax S7 cable socket stripped ends (divided shield, divided core) temperature sensor for measuring instruments with 4-wire input Example: measuring cable K 43 with 5 m standard cable length = K 43/5 Signal cables for chlorine sensors order code cable 1. cable end 2. cable end sensors C 2000 Ø 3 mm, stripped ends stripped ends chlorine sensor with current output 2 wires K Ø 5 mm, 4 wires 4-pin plug stripped ends chlorine sensor with voltage output (4 pins) Example: signal cable C 2000 with 6 m special cable length = C 2000/6 Cables for process (multipin cable) order code cable 1. cable end 2. cable end sensors K 17 Ø 5 mm, 1 shield, 7 wires SMEK socket stripped ends 4-electrode conductivity cell with temperature sensor K 18 K 19 K 39 K-VP Ø 5 mm, 1 shield, 6 wires Ø 5 mm, 1 shield, 1 coax, 4 wires Ø 5 mm, 1 shield, 6 wires Ø 7.5 mm, 1 coax, 1 shield, 6 wires SMEK socket stripped ends 2-electrode conductivity cell with temperature sensor SMEK socket stripped ends ph combination electrode with temperature sensor SMEK socket stripped ends oxygen sensor with temperature sensor Variopin socket stripped ends 2-electrode conductivity cell, 4-electrode conductivity cell, ph combination electrode, oxygen sensor with temperature sensor Example: multipin cable K 39 with 10 m standard cable length = K 39/10 SMEK is another description for SixPlug. 30

36 5. Electrical and process connection (cables, plug connectors, screwable threads PG 13.5) Meinsberg electrodes are equipped with fixed cable (length and plug are available) or plug head for applications in laboratory and process. Sensor with fixed cable type of sensor Kabeltyp cable plugs reference electrode one-wire 4 mm banana plug cable ph/redox combination electrode coaxial cable stripped ends DIN-, BNC-, Cinch plug 2-electrode conductivity cell, oxygen sensor coaxial cable stripped ends BNC plug ph combination electrode with temperature sensor triaxial cable stripped ends German DIN plug and 4 mm banana plug (Y-cable) BNC plug and 4 mm banana plug (Y-cable) BNC plug and Cinch plug (Y-cable) BNC plug and German MiniDIN plug (Y-cable) oxygen sensor with temperature sensor 6-pin cable stripped ends multipin plug (6-pin) stripped ends 31

37 Sensor with plug head type of sensor ph combination electrode, redox combination electrode, 2-electrode conductivity cell, oxygen sensor, temperature sensor ph combination electrode, 2-electrode conductivity cell, 4-electrode conductivity cell, oxygen sensor with temperature sensor plug connector S7 coaxial lab plug head, S7 coaxial plug head with thread PG 13.5 SMEK lab plug head, SMEK plug head with thread PG 13.5, Variopin plug head with thread PG 13.5 Our sensors are compatible to nearly all measuring instruments worldwide, because of using different plug connector systems Table about different plug connections plug heads S7 coaxial lab plug head cable socket S7 cable socket S7 coaxial plug head with thread PG 13.5 S7 cable socket SMEK lab plug head SMEK socket SMEK plug head with thread PG 13.5 SMEK socket Variopin plug head with thread PG 13.5 Variopin socket SMEK is another description for SixPlug. Process connections with thread PG 13.5 screwable thread PG 13.5 example application PG 13.5 head EGA 133 with fixed cable and thread PG 13.5 (head) gel filled ph-/redox combination electrodes, conductivity cells and oxygen sensors with fixed cable PG 13.5 shaft EGA 161 with fixed cable and thread PG 13.5 (shaft) fluid filled ph combination electrodes and reference electrodes with fixed cable or plug head Our sensors can be integrated in every process, because of installing a thread PG 13.5 on electrode head or shaft. 32

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor Vorläufig V Page 1/8 JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor Cell constants K = 0.01 1.0 202922 Series for universal application, e.g. drinking and surface water monitoring,

More information

SenTix 950 SenTix 980

SenTix 950 SenTix 980 SenTix 950 SenTix 980 ph combination electrodes with refillable liquid reference system Operating manual ba75843e01 08/2009 SenTix The latest version of the present operating manual can be found on the

More information

ph Measurement and Control

ph Measurement and Control ph Measurement and Control Tech Tip #14 1997 I. The Need for ph II. ph System Requirements III. ph Electrode Conditioning Procedures IV. How the electrode works V. Identifying the Electrode Components

More information

JUMO tecline HD ph and JUMO tecline HD Rd

JUMO tecline HD ph and JUMO tecline HD Rd Page 1/7 JUMO tecline HD ph and JUMO tecline HD Rd ph and redox combination electrodes in glass shaft version Series 201021 ph electrodes Series 201026 redox electrodes Brief description JUMO tecline HD

More information

Stainless Steel Dissolved Oxygen Electrodes

Stainless Steel Dissolved Oxygen Electrodes Stainless Steel Dissolved Oxygen Electrodes DISSOLVED OXYGEN ELECTRODES The steam sterilizable family of dissolved oxygen electrodes from the phoenix Electrode Company is specifically designed for fermentation

More information

ELECTROCHEMISTRY. Theory and Practice

ELECTROCHEMISTRY. Theory and Practice ELECTROCHEMISTRY Theory and Practice Dr. Axel Bier Lab Product Application Manager - Electrochemistry For more information, please visit: www.hach.com/smartprobes P a g e 2 CONTENT INTRODUCTION 3 HOW TO

More information

HND-R. Hand-held ph, Redox and Temperature Measuring Units

HND-R. Hand-held ph, Redox and Temperature Measuring Units Hand-held ph, Redo and Temperature Measuring Units measuring monitoring analysing HND-R A1 P? OMeasuring O range: ph: 0.00...14.00 Redo (ORP): -1999 mv... +2000 mv Temperature: -5 C...+150 C rh: 0.0 rh...

More information

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately: BOECO PORTABLE PH/ORP/TEMP METER MODEL PT-380 A Simultaneous displays ph or mv and temperature. A Convenient calibration with automatic buffer recognition of European and US buffer sets. Calibration data

More information

Dissolved Oxygen Sensors

Dissolved Oxygen Sensors Instruction Sheet PN 51A-HxDO/rev.F June 2008 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit

More information

Resolution selectable from 0.01 and 0.001 ph. Range -2.000 16.000 ph. Accuracy ± 0.002 ph

Resolution selectable from 0.01 and 0.001 ph. Range -2.000 16.000 ph. Accuracy ± 0.002 ph ph EC DO ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand manual log on stability Interval logging Temperature readout ( C or

More information

ph, redox and I.S.E. electrodes

ph, redox and I.S.E. electrodes ph, redox and I.S.E. electrodes Complete and clear offer which makes easy the choice of the suitable model without user s confusion. ph electrodes: four models for portable instrument, five basic laboratory

More information

REDOX AND REFERENCE ELECTRODE USER MANUAL

REDOX AND REFERENCE ELECTRODE USER MANUAL REDOX AND REFERENCE ELECTRODE USER MANUAL 3 Redox and reference electrode manual Copyright 2012 Unisense A/S Version October 2012 REDOX AND REFERENCE ELECTRODE MANUAL UNISENSE A/S TABLE OF CONTENTS WARRANTY

More information

CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor

CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor CONDUCTIVITY SENSOR Description D0382 Figure 1. The Conductivity Sensor Short Description The Conductivity Sensor can be used to measure either solution conductivity or total ion concentration of aqueous

More information

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S Pen type, separate electrode SOIL PH METER Model : PH-220S Your purchase of this SOIL PH METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and

More information

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system Sistema autolimpiable Dissolved Oxygen Autoclean system Applications: - water treatment - activated sludge - de-nitrification - fish pond Install & forget For special applications, the D.O monitor can

More information

Milwaukee USER MANUAL

Milwaukee USER MANUAL Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: MW600 Smart DO Meter PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery compartment cover on the back of the

More information

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01 Milwaukee Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: SM600 Smart DO Meter Authorized Dealer: ISMIL600 11/01 PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery

More information

Measurement by Ion Selective Electrodes

Measurement by Ion Selective Electrodes Measurement by Ion Selective Electrodes Adrian Vazquez May 8, 2012 Why Use Ion Selective Electrodes? Responsive over a wide concentration range Not affected by color or turbidity of sample Rugged and durable

More information

Compact ph Measuring Instruments

Compact ph Measuring Instruments testo 205, 206, 230 Compact ph Measuring Instruments With innovative probe engineering ph C The new ph measuring instruments with innovative probe engineering Measurement of the ph value plays an important

More information

DISSOLVED OXYGEN PROBE

DISSOLVED OXYGEN PROBE 51970-88 DISSOLVED OXYGEN PROBE Introduction This instruction sheet provides information on the Hach Dissolved Oxygen Probe for use with the sension 6 Dissolved Oxygen Meter. The Dissolved Oxygen Probe

More information

Handbook. Thermo Scientific. ph Electrode Selection Handbook

Handbook. Thermo Scientific. ph Electrode Selection Handbook Handbook Thermo Scientific ph Electrode Selection Handbook Table of Contents ph Theory... 4 ph Electrode Theory... 4 ph versus Temperature Theory... 5 ph Electrode Selection Guide... 6 Thermo Scientific

More information

Conductivity and TDS Meters

Conductivity and TDS Meters Table of Contents Comparison Charts Introduction Portable Meters Waterproof Meters Printing & Logging Portable Meters Bench Meters Combination EC/TDS/pH Meter Page G2 G3 G6 G11 G14 G15 G16 G1 Comparison

More information

THEORY AND APPLICATION OF CONDUCTIVITY

THEORY AND APPLICATION OF CONDUCTIVITY Application Data Sheet ADS 43-018/rev.D January 2010 Theory THEORY AND APPLICATION OF CONDUCTIVITY BACKGROUND Conductivity is a measure of how well a solution conducts electricity. To carry a a solution

More information

DISSOLVED OXYGEN METER Model : DO-5509

DISSOLVED OXYGEN METER Model : DO-5509 DISSOLVED OXYGEN METER Model : DO-5509 Your purchase of this DISSOLVED OXYGEN METER marks a step forward for you into the field of precision measurement. Although this DISSOLVED OXYGEN METER is a complex

More information

OxyGuard. Dissolved Oxygen Probe

OxyGuard. Dissolved Oxygen Probe OxyGuard Dissolved Oxygen Probe Standard type USER MANUAL D02 Standard Probe manual gb 0903 CONTENTS 1. DESCRIPTION 1.1 The OxyGuard Probe... 1 1.3 Which kind of transmitter can be used with the OxyGuard

More information

Operating Instructions

Operating Instructions Operating Instructions FiveEasyPlus ph meter FEP20 Contents Contents 1. Introduction 3 2. Safety measures 3 3. Installation 4 3.1 Installing the electrode arm (optional for FEP20) 4 4. Operating the FiveEasyPlus

More information

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

CYCLE CHEMISTRY ph MEASUREMENT

CYCLE CHEMISTRY ph MEASUREMENT CYCLE CHEMISTRY ph MEASUREMENT David M. Gray and Edward P. Santini Thornton Associates, Waltham MA Electric Utility Chemistry Workshop Champaign, Illinois May 12-14, 1998 Sponsored by University of Illinois

More information

Features. Picture. Specifications

Features. Picture. Specifications Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Temperature Sensor: WQ101 ph Sensor: WQ201 Conductivity Sensor: WQ301

More information

PART 1 - INTRODUCTION...

PART 1 - INTRODUCTION... Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART

More information

ph 200 ph-/redox-/temperature Meter Operating instructions

ph 200 ph-/redox-/temperature Meter Operating instructions ph 200 ph-/redox-/temperature Meter Operating instructions 2 Table of Contents Page 1. Scope of delivery...4 2. System description...4 3. Connections...5 4. Display...7 5. Keypad...7 6. Start up...8 7.

More information

Combination ph/redox (ORP) Sensors

Combination ph/redox (ORP) Sensors Data Sheet SS/AP00 Issue 4 Combination ph/redox (ORP) Sensors AP00 Series Long life large PTFE junction provides resistance to fouling double junction with gelled electrolyte provides better-defined junction

More information

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN

More information

Direct Measurement Method Method 8157 0 to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Direct Measurement Method Method 8157 0 to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor Oxygen, Dissolved DOC316.53.01241 Direct Measurement Method Method 8157 0 to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor Scope and application: For water, wastewater and process

More information

Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE

Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE Sodium DOC316.53.01240 Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE Scope and application: For drinking water and process water. Test preparation Instrument-specific information This procedure

More information

Galvanic Parts Per Million Dissolved Oxygen Systems

Galvanic Parts Per Million Dissolved Oxygen Systems Galvanic Parts Per Million Dissolved Oxygen Systems Model 900 Portable s Model 9100 Model 9200 Model 9300 The Royce line of PPM level dissolved oxygen (DO) analyzers is the largest, most varied line in

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Operating manual. ba75441e. inolab ph/cond 720. Measuring Instrument for ph, Redox, and Conductivity

Operating manual. ba75441e. inolab ph/cond 720. Measuring Instrument for ph, Redox, and Conductivity Operating manual ba75441e inolab ph/cond 720 ph/cond 720 Measuring Instrument for ph, Redox, and Conductivity ba75441e01 03/2004 Accuracy when going to press The use of advanced technology and the high

More information

General Purpose ph/orp Sensors

General Purpose ph/orp Sensors General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 / Rev. F December 2014 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided

More information

Ion-selective Measurements

Ion-selective Measurements Ion-selective Measurements Ion-selective measurement is a method for determining the concentration of dissolved ions. Potassium ions, sodium ions, fluoride or chloride are examples of such cations and

More information

PN 44-6033/rev. D December 2010. Theory and Practice of ph Measurement

PN 44-6033/rev. D December 2010. Theory and Practice of ph Measurement PN 44-6033/rev. D December 2010 Theory and Practice of ph Measurement THEORY AND PRACTICE OF ph MEASUREMENT TABLE OF CONTENTS THEORY AND PRACTICE OF ph MEASUREMENT TABLE OF CONTENTS Section Title Page

More information

InLab Sensors. ph ORP Conductivity Ion Concentration Dissolved Oxygen. Origin of Precision Proven Sensor Technology for Safe Results

InLab Sensors. ph ORP Conductivity Ion Concentration Dissolved Oxygen. Origin of Precision Proven Sensor Technology for Safe Results InLab Sensors InLab Sensors ph ORP Conductivity Ion Concentration Dissolved Oxygen Origin of Precision Proven Sensor Technology for Safe Results Experience & Innovation InLab Sensors Developed for Your

More information

Operator Quick Guide EC SENSOR

Operator Quick Guide EC SENSOR Operator Quick Guide EC SENSOR Revision G - 24/04/2008 General Information About This Guide The information in this guide has been carefully checked and is believed to be accurate. However, Hach Ultra

More information

Care and use guide. Contents. a handy solution made easy. www.getbluelab.com. page

Care and use guide. Contents. a handy solution made easy. www.getbluelab.com. page Care and use guide Contents page Features Quick guide Before use To operate Important - ph pen probe care 4 Cleaning 5 Battery replacement 5 Hydration 6 Calibration 6 Error messages 7 Troubleshooting guide

More information

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic

More information

USEPA Electrode Method Method 8156

USEPA Electrode Method Method 8156 ph DOC316.53.01245 USEPA Electrode Method Method 8156 Scope and application: For drinking water 1, wastewater 2 and process water. 1 Based on Standard Method 4500-H+B, ASTM Method D1293-95 and USEPA Method

More information

The Effects of Temperature on ph Measurement

The Effects of Temperature on ph Measurement The Effects of Temperature on ph Measurement Authors: John J. Barron Colin Ashton & Leo Geary Technical Services Department, Reagecon Diagnostics Ltd, Shannon Free Zone, County Clare, Ireland Abstract

More information

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment

More information

DPST-ELMETRON-meters. Contents: ELMETRON 100 series pocket instruments. ELMETRON 411 series portable meters. ELMETRON 401 series portable meters

DPST-ELMETRON-meters. Contents: ELMETRON 100 series pocket instruments. ELMETRON 411 series portable meters. ELMETRON 401 series portable meters ELMETRON meters Robust and reliable pocket tester or computerized laboratory equipment Excellent friendly priced quality for research, education and process control 2 DPST-ELMETRON-meters You need a robust,

More information

MSFET 3332. MICROSENS Miniature ph Sensor Module

MSFET 3332. MICROSENS Miniature ph Sensor Module Product Data Sheet MSFET 3332 MICROSENS Miniature ph Sensor Module Ta2O5 gate Ion Sensitive Field Effect transistor (ISFET) The MSFET3332 ph sensor module comprises a ph-isfet sensing element, an integrated

More information

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3 Measuring ph in Water or CaCl2 Using a ph Meter Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3 PREPARING THE ph METER FOR USE (Calibration and Buffer Solutions) 4 When is Calibration

More information

Stainless steel process fittings

Stainless steel process fittings Page 1/6 Stainless steel process fittings Installation in pipe systems Installation in tanks and vessels Hygienic version FDA conformity of materials Probe length 120 mm 120 mm Availability of various

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

Ion Selective Electrodes

Ion Selective Electrodes Ion Selective Electrodes OAKTON has a large selection of Ion Selective Electrodes () to suit a wide variety of applications. Each electrode has a typical response time of 20 to 30 seconds but will vary

More information

6 H2O + 6 CO 2 (g) + energy

6 H2O + 6 CO 2 (g) + energy AEROBIC RESPIRATION LAB DO 2.CALC From Biology with Calculators, Vernier Software & Technology, 2000. INTRODUCTION Aerobic cellular respiration is the process of converting the chemical energy of organic

More information

Trace Dissolved Oxygen Sensor

Trace Dissolved Oxygen Sensor Instruction Sheet PN 51A-499ATRDO/rev.G September 2010 Model 499A TrDO Trace Dissolved Oxygen Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION

More information

Reaction Torque Sensor

Reaction Torque Sensor Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.

More information

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL 430 350/REV A/10-03 MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL CONTENTS Introduction 1 Specification 2 Installation 3 Displays 3-4

More information

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC Common Problems with Online Water Quality Analyzers Greg Macy Director AquatiPro LLC Objectives Diagnosing Colorimetric Analyzers Identifying Common Problems with Sodium Analyzers Troubleshooting ph Analyzers

More information

Instruction Manual HI 9146. Portable Waterproof Microprocessor Dissolved Oxygen Meter

Instruction Manual HI 9146. Portable Waterproof Microprocessor Dissolved Oxygen Meter Instruction Manual HI 9146 Portable Waterproof Microprocessor Dissolved Oxygen Meter w w w. h a n n a i n s t. c o m Dear Customer, Thank you for choosing a Hanna Product. Please read this instruction

More information

TECHNICAL DATASHEET Incremental Encoder RI 80-E

TECHNICAL DATASHEET Incremental Encoder RI 80-E Incremental 30-45 hollow shaft Rugged mechanical design Unbreakable disc Integrated diagnostic system Wide voltage range DC 5-30 V Isolated shaft NUMBER OF PULSES 1024 / 2048 / 2500 / 4096 / 5000 / 10000

More information

A Potentiometric Analysis of Fluoride Ion in Toothpaste

A Potentiometric Analysis of Fluoride Ion in Toothpaste CHEM 311L Quantitative Analysis Laboratory Revision 2.0 A Potentiometric Analysis of Fluoride Ion in Toothpaste In this laboratory exercise, we will analyze a toothpaste sample for its Fluoride Ion (F

More information

Features, Limitations & Potential Errors

Features, Limitations & Potential Errors MINIMIZING USER ERRORS IN ph MEASUREMENTS Features, Limitations & Potential Errors of the Tools of ph Measurements Advanced Sensor Technologies, Inc. 603 North Poplar Street Orange CA 92868-1011 USA General

More information

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61 Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:

More information

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510 User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

UltraBasic Benchtop ph Meter Operation Manual

UltraBasic Benchtop ph Meter Operation Manual UltraBasic Benchtop Meter Operation Manual UB-5 Denver Instrument Measuring 4 4 7 10 Meter 22.2 C 4.06 UltraBasic 902388.1 Rev. A UltraBasic Meter Quick Reference 1. Connect a AC adapter to the power connection.

More information

Standard methods in water analysis

Standard methods in water analysis Branch General analytical laboratories; water analysis Keywords Water analysis; standard methods; ASTM; DIN; ISO; USP; EPA; SLMB; EN; SCA; titration; ion chromatography; voltammetry; branch 1; branch 2

More information

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020 Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and vibration resistant

More information

ph Measurements of Common Substances

ph Measurements of Common Substances Chem 100 Section Experiment 10 Name Partner s Name Introduction ph Measurements of Common Substances The concentration of an acid or base is frequently expressed as ph. Historically, ph stands for the

More information

RTD Temperature Probe for the Food/Pharmaceutical Industry

RTD Temperature Probe for the Food/Pharmaceutical Industry sales@jumo.co.uk Data Sheet 902810 Page 1/9 RTD Temperature Probe for the Food/Pharmaceutical Industry For temperatures between -50 and +250 C Protection type up to IP69 according to DIN EN 60529 (IP69K

More information

Portable digital microprocessor thermometers with interchangeable probes

Portable digital microprocessor thermometers with interchangeable probes JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B, Accessories Temperature Sensors for Injection Molding Types 6192B, 6193B, 6194B, 6195B Temperature sensors for measuring the contact temperature directly in the cavity at the surface of the solidified

More information

Safety at a high level!

Safety at a high level! SIKA Level Switch SIKA Level Switch Safety at a high level! Convincing Advantages easy and reliable method to monitor fluid levels proven float principle easy side installation using threads ¾" or ½" BSP

More information

Models SFP33 & SFP32 Pressure Transmitters

Models SFP33 & SFP32 Pressure Transmitters SFP33 Flow-Through Pressure Transmitter SFP32 Single-Ended Pressure Transmitter DS-PR-SFP-eng April, 2016 Data Sheet Models SFP33 & SFP32 Pressure Transmitters Pressure Brooks Seal Free Pressure Measurement

More information

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features Features Applications The PMP 4000 Series provides a complete range of high level voltage output pressure transducers offering advanced levels of measurement accuracy, stability and flexibility from a

More information

MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS

MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS Measuring and Controlling Equipment ensuring required water quality in public pools. This is fully automatic measuring and controlling equipment with

More information

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending User Guide ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens Patent Pending Getting Started Remove the cap from the bottom of the ExStik TM to expose the electrode bulb and reference

More information

Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes

Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes Tech Note Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes Probe Care and Maintenance Periodic cleaning and membrane changes are required to keep your sensors operating properly. Follow

More information

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation Introduction The importance of keeping cooling tower water in proper chemical

More information

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN 2011. In Use Date: 2/1/2011 Discontinued Date:

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN 2011. In Use Date: 2/1/2011 Discontinued Date: PROCEDURE COVERSHEET Procedure Title: ph (Urine, Body Fluid, Platelet Samples) Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN 2011 Laboratory Director: TED KURTZ, MD (PARNASSUS & CHINA

More information

Multi-Parameter Electrochemical / Optical Water Quality System

Multi-Parameter Electrochemical / Optical Water Quality System Product Data Sheet PDS 71-WQS/rev.H September 2011 Model WQS Multi-Parameter Electrochemical / Optical Water Quality System COMPLETE SYSTEM INCLUDES sensors, cable, and instruments. MEASURES ph, ORP, Conductivity,

More information

Eutech 2700 Series. Bench Meters. ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature

Eutech 2700 Series. Bench Meters. ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature Eutech 2700 Series Bench Meters ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature Features Comprehensive Backlit Display All Measurements Include Temperature Display Up To 500

More information

General Purpose ph/orp Sensor

General Purpose ph/orp Sensor Instruction Sheet General Purpose ph/orp Sensor Sensors LIQ_MAN_ABR_3900 October 2014 General Purpose ph/orp Sensor Specifications Figure 1. 3900 Insertion/Submersion Sensor Sensor Type: General purpose

More information

Understanding electrical conductivity

Understanding electrical conductivity World Bank & Government of The Netherlands funded Training module # WQ - 08 Understanding electrical conductivity New Delhi, May 1999 CSMRS Building, 4th Floor, Olof Palme Marg, Hauz Khas, New Delhi 11

More information

white paper reviews why the chlor-alkali process is so damaging to ph electrodes and discusses a sensor design that has

white paper reviews why the chlor-alkali process is so damaging to ph electrodes and discusses a sensor design that has INGOLD White Paper Leading Process Analytics No More Tears Elevated temperatures, presence of chlorine and high salt concentration throughout the chlor-alkali process make stable and reliable ph measurement

More information

ph/redox Measurement MyPro CPM 431

ph/redox Measurement MyPro CPM 431 Technical Information TI 173C/07/en/06.02 50088309 ph/redox Measurement MyPro CPM 431 Two-wire transmitter for ph and redox with Hart and PROFIBUS-PA communication for use in Ex and non-ex areas Application

More information

Corrosion experiments in amine solutions

Corrosion experiments in amine solutions Corrosion experiments in amine solutions Andreas Grimstvedt Process technology SINTEF Materials and chemistry Wenle He Applied mechanics and corrosion SINTEF Materials and chemistry 1 Contents of presentation

More information

Discovering Electrochemical Cells

Discovering Electrochemical Cells Discovering Electrochemical Cells Part I Electrolytic Cells Many important industrial processes PGCC CHM 102 Cell Construction e e power conductive medium What chemical species would be present in a vessel

More information

TurbiDirect TurbiCheck TurbiCheck WL

TurbiDirect TurbiCheck TurbiCheck WL Turbidity 128 TurbiDirect TurbiCheck TurbiCheck WL www.lovibond.com General Catalogue February 2013 Turbidity measurement The term "turbidity is used to describe the cloudy or milky appearance of liquid

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

User Guide. 9708 Dissolved Oxygen Probes

User Guide. 9708 Dissolved Oxygen Probes User Guide 9708 Dissolved Oxygen Probes Introduction The Thermo Scientific Orion 9708 dissolved oxygen probe simplifies measurements of dissolved oxygen, particularly Biochemical Oxygen Demand (BOD).

More information

Chloride and Salinity

Chloride and Salinity INTRODUCTION Chloride Chloride and Chloride, in the form of the Cl ion, is one of the major inorganic anions, or negative ions, in saltwater and freshwater. It originates from the dissociation of salts,

More information

DETERMINING THE MASS OF A COPPER ATOM

DETERMINING THE MASS OF A COPPER ATOM DETERMINING THE MASS OF A COPPER ATOM LAB ADV.31 From Vernier Software & Technology, 2004 STANDARDS ADDRESSED 3.4.10 A Explains concepts about the structure and properties of matter. 3.4.12 A Apply concepts

More information

The Electrical Control of Chemical Reactions E3-1

The Electrical Control of Chemical Reactions E3-1 Experiment 3 The Electrical Control of Chemical Reactions E3-1 E3-2 The Task In this experiment you will explore the processes of oxidation and reduction, in which electrons flow between materials, and

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Compact Water Quality Meter B-700 series

Compact Water Quality Meter B-700 series Compact Water Quality Meter B-700 series Actual Size Compact Water Quality Meter Debut! HORIBA s 60 years of sensor engineering realize accurate direct measurement from only a single drop on the unique

More information

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30 85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08

More information