Power Station Photovoltaic Energy
|
|
|
- Anne Clarke
- 9 years ago
- Views:
Transcription
1 Power Station Photovoltaic Energy A Complete Range of Power Stations for Grid-connected Photovoltaic Plants
2
3 Photovoltaic Energy 3
4 Power Station A New Generation of Power Stations 4
5 After years of success in the photovoltaic market, INGETEAM has further improved its product offering introducing a new line of power stations named Ingecon Sun Power Station, suitable for any PV installation site. The Ingecon Sun Power Station is an integrated equipment that manages the power produced by medium and large scale solar photovoltaic plants for medium voltage grid-connected applications. Plug&Play Installation Top Efficiency and Cost Reduction Flexibility and Modularity Accessibility 5
6 Power Station MEDIUM VOLTAGE PV Inverter kwac kV INGETEAM has developed a new line of the Ingecon Sun Power Stations with power ratings from 300 to 2.300kWp with all the necessary equipment to adapt the energy produced by the plant to the MV grid of the local distributor. The Ingecon Sun Power Station solutions offer top flexibility and an easyto-install configuration, and can be adapted to suit the standards of any countries globally. Comparing to the other photovoltaic solutions to be assembled on site, the Ingecon Sun Power Stations are easy to transport, time- and cost-efficient and offer leading results in reliability. The Ingecon Sun Power Stations are supplied with all the internal wiring and fully tested by Ingeteam s highly qualified technicians. Available in four versions: Ingecon Sun Power Station SHE15 15ft insulated shelter Ingecon Sun Power Station SHE20 20ft insulated shelter Ingecon Sun Power Station CON20 20ft insulated container Ingecon Sun Power Station CON40 40ft insulated container Plug&Play Installation The Ingecon Sun Power Station equipments are easy and rapid to install. Designed and manufactured to avoid the need of assembly operations on-site, they significantly reduce the time and costs of installation. The connection to the photovoltaic inverters and to the distribution grid requires only few simple steps. Top Efficiency and Cost Reduction Manufactured with high-quality materials, our products allow to maximize performances and reliability, as well as to optimize the costs. The INGETEAM inverters, the heart of the Ingecon Sun Power Station, ensure industry-leading results in terms of performance and durability. 6
7 Flexibility and Modularity The great flexibility of the Ingecon Sun Power Station, combined with the modularity of INGETEAM inverters, allows to optimize the configuration of the photovoltaic plant to meet any customer s needs and installation requirements, thanks to their modular design in both POWER MAX M series with multi-mppt configuration and X series with Master/ Slave configurations. Accessibility The Ingecon Sun Power Station products are designed to provide full access to the equipment inside, making inspection and maintenance activities easier and significantly reducing service down times and costs. The system includes Ingecon Sun PowerMax Photovoltaic inverters in multi-mppt configuration or in Master/Slave configuration up to 2.3 MWp. LV parallel switchgear protecting the interconnection between the inverters and the transformer. LV/MV transformer up to 36 kv. MV switchgears, available in different configurations according to the type of application. Auxiliary Services switchgear. Cooling system. Complete wiring (power supply lines, lighting system, plugs, earthing, etc.) Safety devices. Optional equipment: In addition to the standard equipment, the Ingecon Sun Power Station can be supplied with the following options: Fiscal energy meter with GSM communication module for remote monitoring. LV/LV transformer for BTAUX auxiliary services switchgear power supply. UPS for auxiliary services. Ingecon Sun ComBox centralized communication system with RS485/ USB/ETHERNET interfaces. GSM/GPRS modem. SCADA system for photovoltaic plant monitoring. On-site plant start-up. 7
8 Power Station SHE15 The most compact solution on the market designed by Ingeteam. All the devices required for a multi-megawatt system incorporated into a single shelter. Maximize your investment with minimal effort Ingecon Sun PowerStation SHE 15 is a compact, customisable and flexible solution that can be configured to suit each customer s requirements. Thanks to its panel-based structure, the internal layout can be customised to incorporate various Ingecon Sun inverters. Ideal for low environmental impact applications. Extremely robust and long-lasting The shelter can be easily transported by road, thanks to its small dimensions and low overall weight. The hot galvanised steel structure is designed to guarantee maximum mechanical strenght and durability. The walls and roof contain a 50 mm rigid fire-proof polyurethane foam filling, to guarantee perfect water resistance and correct thermal insulation. Equipped with everything necessary Inverters, Low Voltage parallel cabinet, auxiliary services panel, medium voltage cubicle and LV/MV transformer. Maximum stability All the devices are anchored to the base, to guarantee the maximum stability of the structure. The varnish used guarantees maximum protection against adverse weather conditions. Efficiency Power Station Vdc= V Main Features Power from 300 to kwp. Compact design. Plug&Play solution. Customizable. Benefits Extremely versatile. Industry-leading performances. Maximum return of investment. Guarantee of quality. Electrical Protections DC and AC Class II surge arresters. DC breaker with door control. DC fuses. AC thermal magnetic circuit breaker with door control. DC insulation monitor. Anti-islanding monitoring system with automatic disconnection. Protection against short-circuits and output overloads. Efficiency (%) Emergency button for the inverters. Disconnection system in case of LV/MV transformer overheat. Emergency disconnecting pushbutton accessible from the outside. Power (kw) 8
9 SHE15 Wing Complete accessibility Thanks to its innovative design, all devices are readily accessible, thereby making it easier to inspect, maintain and repair the Ingecon Sun Power- Station SHE 15. The transformer compartment door is equipped with an Arel safety lock with a blocking code. Innovative ventilation system The internal temperature is controlled by a centrifugal fan system. A number of internal and external probes guarantee a constant ambient temperature. The incoming air is filtered through special grids mounted on the bottom of the walls. Optional equipment In addition to the standard equipment, the Ingecon Sun Power Station SHE15 can be supplied with the following options: Fiscal energy meter with GSM communication module for remote monitoring. LV/LV transformer for auxiliary services switchgear power supply. UPS for auxiliary services. Ingecon Sun ComBox centralized communication system with RS485/USB/ETHERNET interfaces. GSM/GPRS modem SCADA system for photovoltaic plant monitoring. On-site plant start-up. Dimensions (mm) Dimensions SHE15 version Body dimensions [mm] LxDxH Overall dimensions with all doors open [mm] Foundation dimensions [mm]
10 SHE15 Wing Power Station Physical, Electrical and Environmental characteristics Number of power modules Cooling System Type IP43 Ventilated version Inverter compartment (1) Transformer compartment Forced air cooling by thermally-controlled centrifugal fans Air flow 6000 m3/h 6000 m3/h 6000 m3/h Power Consumption 1950 W 2770 W 3180 W Air flow 6000 m3/h 6000 m3/h 6000 m3/h Power Consumption Extraction and intake air grid 720 W 720 W 720 W Anti-rain model General Information Auxiliary power supply (400V standard) V three phase with neutral 50/60Hz Operating Temperature Range (2)(3) From -30 C to +50 C Relative Humidity 0-95 % Installation Altitude (4) 3000 m above sea level Certifications Calculation report Safety and EMC standards CE, EN 50178, EN , EN , EN , EN , FCC part 15 Grid Standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI V1, CEI 0-16, Annexes A68 e A70 TERNA, CEI 0-21, IEEE1547, Arrêté , 659/2 Equipment Inverter versions M series (Multi MPPT) or X series (Master/Slave) BT POWER LV switchgear One automatic switchgear for each inverter BT-AUX switchgear BASE version (FULL version optional) LV/MV transformer Dry type cast resin or oil insulated MV switchgear Protection cells 1P or 1P-2L Internal lighting 2 x 28 W fluorescent lamps Emergency lighting 2 x 36 W fluorescent lamps Auxiliary power outlet (220V standard) V single phase 50/60Hz Safety interlocks AREL security lock for LV/MV transformer compartment door Fire safety kit 5 Kg CO 2 fire extinguisher MV safety kit Class 3 insulated gloves and 30 kv insulated footboard Safety kit First aid kit and signals Support system n. 8 30x30 cm brackets Mechanical Details Structure Steel Insulation Sandwich panels containing a 50 mm rigid fire-proof polyurethane foam filling Notes: (1) Consumption inverter ventilation system included. (2) Rated output power indicated in the Technical Characteristics tables is guaranteed up to 45 C operating temperature. Derating above 45 C of 1.8% for each C of increase until 50 C operating temperature. (3) Temperatures below -20 C, requires optional heater. (4) For altitudes above 1000 mt the nominal power temperature is derated of 4.5 C every 1000 mt. 10
11 SHE15 Layout Wing Layout weather station pole single door lv compartment extraction grids double doors mv compartment double doors transformer compartment wing door intake air grids lv POWER cubicle lv aux cubicle inverter lv/mv transformer N 4 fans mv cubicle
12 Power Station SHE15 Wing Manholes layout 6000 concrete slab 300 mm double grid ø8 20x20 earth manhole 40x40 with its cover concrete slab size pipe ø32 earth connection N 2 concrete manhole 50x50 (MT section) 5000 concrete manhole 50x50 with its cover (mv section) pipe ø for wiring cables concrete manhole 50x50 with its cover (dc entry) concrete manhole 50x50 (dc entry) +50mm pipe ø for wiring cables not isolated earthcable ground level concrete manhole 50x50 with its cover (dc entry) concrete manhole 50x50 with its cover (mv section) Plan view 7900 Recommended area for opening the doors and for maintenance of devices 6000 concrete slab 300 mm double grid ø8 20x20 earth manhole 40x40 with its cover concrete manhole 50x50 with its cover (mt section) concrete manhole 50x50 with its cover (dc entry) slab foundation mq 30,00 concrete mc 9,00 +50mm concrete manhole 50x50 with its cover (dc entry) ground level concrete manhole 50x50 with its cover (mt section) 12
13 Foundation Left side view ground level +50 mm concrete slab 300 mm double grid Ø8 20x20 concrete manhole 50x50 with its cover (DC entry) pipe Ø160 for wiring cables Frontal view ground level +50 mm concrete slab 300 mm double grid Ø8 20x20 concrete manhole 50x50 with its cover pipe Ø160 for wiring cables 13
14 Power Station SHE20 The very latest technological development by Ingeteam. All the devices required for a multi-megawatt system incorporated into a single shelter. Maximize your investment with minimal effort Ingecon Sun PowerStation SHE 20 is a compact, customisable and flexible solution that can be configured to suit each customer s requirements. Thanks to its panel-based structure, the internal layout can be customised to incorporate various Ingecon Sun inverters. Ideal for low environmental impact applications. Extremely robust and long-lasting The shelter can be easily transported by road, thanks to its small dimensions and low overall weight. The hot galvanised steel structure is designed to guarantee maximum mechanical strenght and durability. The walls and roof contain a 50 mm rigid fire-proof polyurethane foam filling, to guarantee perfect water resistance and correct thermal insulation. Equipped with everything necessary Inverters, Low Voltage parallel cabinet, auxiliary services panel, medium voltage cubicle and LV/MV transformer. Maximum stability All the devices are anchored to the base, to guarantee the maximum stability of the structure. The varnish used guarantees maximum protection against adverse weather conditions. Efficiency Efficiency (%) Power Station Vdc= V Power (kw) Power (kw) Main Features Power from 300 to kwp. Compact design. Plug&Play solution. Customizable. Benefits Extremely versatile. Industry-leading performances. Maximum return of investment. Guarantee of quality. Electrical Protections DC and AC Class II surge arresters. DC breaker with door control. DC fuses. AC thermal magnetic circuit breaker with door control. DC insulation monitor. Anti-islanding monitoring system with automatic disconnection. Protection against short-circuits and output overloads. Emergency button for the inverters. Disconnection system in case of LV/MV transformer overheat. Emergency disconnecting pushbutton accessible from the outside. 14
15 Internal view SHE20 Wing Complete accessibility Thanks to its innovative design, all devices are readily accessible, thereby making it easier to inspect, maintain and repair the Ingecon Sun Power- Station SHE 20. The transformer compartment door is equipped with an Arel safety lock with a blocking code. Innovative ventilation system The internal temperature is controlled by a centrifugal fan system. A number of internal and external probes guarantee a constant ambient temperature. The incoming air is filtered through special grids mounted on the bottom of the walls. Optional equipment In addition to the standard equipment, the Ingecon Sun Power Station SHE20 can be supplied with the following options: Fiscal energy meter with GSM communication module for remote monitoring. LV/LV transformer for auxiliary services switchgear power supply. UPS for auxiliary services. Ingecon Sun ComBox centralized communication system with RS485/USB/ETHERNET interfaces. GSM/GPRS modem SCADA system for photovoltaic plant monitoring. On-site plant start-up. Dimensions (mm) Dimensions SHE20 version Body dimensions [mm] LxDxH Overall dimensions with all doors open [mm] Foundation dimensions [mm]
16 SHE20 Wing Power Station Physical, Electrical and Environmental characteristics Number of power modules Cooling System Type IP43 Ventilated version Inverter compartment (1) Transformer compartment Forced air cooling by thermally-controlled centrifugal fans Air flow 6000 m3/h 6000 m3/h 6000 m3/h m3/h m3/h m3/h m3/h Power Consumption 1950 W 2770 W 3180 W 4720 W 5540 W 5950 W 6360 W Air flow 6000 m3/h 6000 m3/h 6000 m3/h 6000 m3/h 6000 m3/h 6000 m3/h 6000 m3/h Power Consumption Extraction and intake air grid 720 W 720 W 720 W 720 W 720 W 720 W 720 W Anti-rain model General Information Auxiliary power supply (400V standard) V three phase with neutral 50/60Hz Operating Temperature Range (2)(3) From -30 C to +50 C Relative Humidity 0-95 % Installation Altitude (4) 3000 m above sea level Certifications Calculation report Safety and EMC standards CE, EN 50178, EN , EN , EN , EN , FCC part 15 Grid Standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI V1, CEI 0-16, Annexes A68 e A70 TERNA, CEI 0-21, IEEE1547, Arrêté , 659/2 Equipment Inverter versions M series (Multi MPPT) or X series (Master/Slave) BT POWER LV switchgear One automatic switchgear for each inverter BT-AUX switchgear BASE version (FULL version optional) LV/MV transformer Dry type cast resin MV switchgear Protection cells 1P or 1P-2L Internal lighting 2 x 28 W fluorescent lamps Emergency lighting 2 x 36 W fluorescent lamps Auxiliary power outlet (220V standard) V single phase 50/60Hz Safety interlocks AREL security lock for LV/MV transformer compartment door Fire safety kit 5 Kg CO2 fire extinguisher MV safety kit Class 3 insulated gloves and 30 kv insulated footboard Safety kit First aid kit and signals Support system n. 8 30x30 cm brackets Mechanical Details Structure material Steel Insulation Sandwich panels containing a 50 mm rigid fire-proof polyurethane foam filling Notes: (1) Consumption inverter ventilation system included. (2) Rated output power indicated in the Technical Characteristics tables is guaranteed up to 45 C operating temperature. Derating above 45 C of 1.8% for each C of increase until 50 C operating temperature. (3) Temperatures below -20 C, requires optional heater. (4) For altitudes above 1000 mt the nominal power temperature is derated of 4.5 C every 1000 mt. 16
17 SHE20 Wing Layout weather station pole wing door wing door inverter 2 extraction grids wing door inverter 1 double doors transformer compartment intake air grids mm lv/mv TransfoRMER lv Power cubicle Inverter 1 lv aux cubicle MV CUBICLE N. 6 FANS Inverter
18 Power Station SHE20 Wing Manholes layout N 2 concrete manhole 50x50 (mv section) not isolated earth cable 8000 concrete slab 300 mm double grid ø8 20x20 concrete manhole 50x50 (dc entry) concrete manhole 50x50 with its cover (mt section) mm concrete slab size concrete manhole 50x50 with its cover (dc entry) concrete manhole 50x50 with its cover (dc entry) pipe ø160 for wiring cables pipe ø32 for earth connection not needed for configuration with 1 inverter pipe ø160 for wiring cables earth manhole 40x40 with its cover ground level concrete manhole 50x50 with its cover (mv section) concrete manhole 50x50 with its cover (dc entry) Plan view concrete slab 300 mm double grid ø8 20x earth manhole 40x40 with its cover Recommended area for opening the doors and for maintenance of devices 8000 concrete manhole 50x50 with its cover (mv section) 500 concrete manhole 50x50 with its cover (dc entry) concrete manhole 50x50 with its cover (dc entry) 6830 earth manhole 40x40 with its cover platea sm 40,00 CONCRETE mc 12,00 not needed for configuration with 1 inverter ground level concrete manhole 50x50 with its cover (mv section) concrete manhole 50x50 with its cover (dc entry) 18
19 Foundation Left side view concrete slab 300 mm double grid Ø8 20x20 ground level +50 mm concrete manhole 50x50 with its cover Front view ground level +50 mm concrete slab 300 mm double grid Ø8 20x20 concrete manhole 50x50 with its cover pipe Ø160 for wiring cables 19
20 SHE20 Tunnel Power Station Physical, Electrical and Environmental characteristics Number of power modules Cooling System Type Forced air cooling by thermally-controlled centrifugal fans IP43 Ventilated version Inverter compartment (1) Transformer compartment Air flow 6000 m3/h 6000 m3/h 6000 m3/h Power Consumption 1950 W 2770 W 3180 W Air flow 6000 m3/h 6000 m3/h 6000 m3/h Power Consumption Extraction and intake air grid 720 W 720 W 720 W Anti-rain model General Information Auxiliary power supply (400V standard) V three phase with neutral 50/60Hz Operating Temperature Range (2)(3) From -30 C to +50 C Relative Humidity 0-95 % Installation Altitude (4) 3000 m above sea level Certifications Calculation report Safety and EMC standards CE, EN 50178, EN , EN , EN , EN , FCC part 15 Grid Standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI V1, CEI 0-16, Allegati A68 e A70 TERNA, CEI 0-21, IEEE1547, Arrêté , 659/2 Equipment Inverter versions M series (Multi MPPT) or X series (Master/Slave) BT POWER LV switchgear One automatic switchgear for each inverter BT-AUX switchgear BASE version (FULL version optional) LV/MV transformer Dry type cast resin MV switchgear Protection cells 1P or 1P-2L Internal lighting 2 x 28 W fluorescent lamps Emergency lighting 2 x 36 W fluorescent lamps Auxiliary power outlet (220V standard) V single phase 50/60Hz Safety interlocks AREL security lock for LV/MV transformer compartment door Fire safety kit 5 Kg CO 2 fire extinguisher MV safety kit Class 3 insulated gloves and 30 kv insulated footboard Safety kit First aid kit and signals Support system n. 8 30x30 cm brackets Mechanical Details Structure material Steel Insulation Sandwich panels containing a 50 mm rigid fire-proof polyurethane foam filling Notes: (1) Consumption inverter ventilation system included. (2) Rated output power indicated in the Technical Characteristics tables is guaranteed up to 45 C operating temperature. Derating above 45 C of 1.8% for each C of increase until 50 C operating temperature. (3) Temperatures below -20 C, requires optional heater. (4) For altitudes above 1000 mt the nominal power temperature is derated of 4.5 C every 1000 mt. 20
21 SHE20 Tunnel Layout weather station pole DOUBLE doors extraction grids double doors transformer compartment intake air grids 8148 Inverter LV/MV TRANSFORMER mv CUBICLE LV AUX CUBICLE LV POWER CUBICLE
22 Power Station SHE20 Tunnel Manholes layout not isolated earth cable 8000 concrete slab 300 mm double grid ø8 20x20 pipe ø32 for earth connection N 2 concrete manhole 50x50 (dc entry) concrete slab size +55mm concrete manhole 50x50 with its cover (dc entry) concrete manhole 50x50 with its cover (mt section) 5000 pipe ø160 for wiring cables concrete manhole 50x50 N 2 concrete manhole 50x50 (mv section) pipe ø32 for earth connection pipe ø160 for wiring cables earth manhole 40x40 with its cover ground level concrete manhole 50x50 with its cover (dc entry) concrete manhole 50x50 with its cover (dc entry) Plan view Recommended area for opening the doors and for maintenance of devices earth manhole 40x40 with its cover concrete manhole 50x50 with its cover (mv section) concrete manhole 50x50 with its cover (dc entry) 4500 earth manhole 40x40 with its cover concrete manhole 50x50 with its cover (mv section) concrete manhole 50x50 with its cover (dc entry) 22
23 Foundation Left side view concrete slab 300 mm double grid Ø8 20x20 ground level +50 mm concrete manhole 50x50 with its cover Front view ground level +50 mm concrete slab 300 mm double grid Ø8 20x20 concrete manhole 50x50 with its cover pipe Ø160 for wiring cables 23
24 Power Station CON20 The Ingecon Sun PowerStation CON 20 offers a standard solution, designed to be marketed at a world level. Thanks to its optional CSC RINA certification, it can be shipped by sea to anywhere in the world. Robust and long-lasting design Its welded galvanised steel monoblock structure guarantees maximum mechanical strength and durability. The walls and roof contain a 50 mm rigid fire-proof polyurethane foam feeling, to guarantee perfect water resistance and correct thermal insulation. Equipped with everything necessary Inverters, Low Voltage parallel cabinet, auxiliary services panel, medium voltage cubicle and LV/MV transformer. Maximum stability All the devices are anchored to the base, to guarantee the maximum stability of the structure. The varnish used guarantees maximum protection against adverse weather conditions. Main Features Power from 300 to 2,300 kwp. Extremely compact design. Plug & play solution. Benefits Extremely versatile. High efficiency. Maximum returns on investment. Guarantee of quality. Electrical Protections Reverse polarity. Efficiency Power Station Vdc= V Output short-circuits and overloads. DC breaker with door control. DC fuses. AC thermal-magnetic breaker with door control. DC and AC voltage surge suppressors. Anti-islanding monitoring system with automatic disconnections Insulation control. Efficiency (%) Emergency button. Disconnection system should the LV/MV transformer overheat. Emergency disconnection button, accessible from outside. Power (kw) 24
25 CON20 Wing Complete accessibility Thanks to its innovative design, all devices are readily accessible, thereby making it easier to inspect, maintain and repair the Ingecon Sun PowerStation CON 20. The transformer compartment door is equipped with an Arel safety lock with a blocking code. Innovative ventilation system The internal temperature is controlled by a centrifugal fan system. A number of internal and external probes guarantee a constant ambient temperature. The incoming air is filtered through special sand trap grids mounted on the bottom of the walls. Optional equipment In addition to the standard features, each Ingecon Sun PowerStation can be supplied with the following options: Energy meter with GSM system for remote metering. LV/LV transformer for the power supply to the BT-AUX auxiliary services panel. UPS for auxiliary services. Ingecon Sun ComBox, centralised communication system with RS-485/USB/ ETHERNET interfaces. GSM/GPRS Modem. SCADA monitoring system. Start-up at the place of installation. CSC RINA certificate. Dimensions (mm) Dimensions CON20 version Body dimensions [mm] LxDxH Overall dimensions with all doors open [mm] Foundation dimensions [mm]
26 CON20 Wing Power Station Physical, Electrical and Environmental characteristics Number of power modules Cooling System Type IP54 Ventilated version Inverter compartment (1) Transformer compartment Forced air cooling by thermally-controlled centrifugal fans Air flow 6000 m3/h 6000 m3/h 6000 m3/h m3/h m3/h m3/h m3/h Power Consumption 1950 W 2770 W 3180 W 4720 W 5540 W 5950 W 6360 W Air flow 6000 m3/h 6000 m3/h 6000 m3/h 6000 m3/h 6000 m3/h 6000 m3/h 6000 m3/h Power Consumption Extraction and intake air grid 720 W 720 W 720 W 720 W 720 W 720 W 720 W Anti-rain & Sand Trap model General Information Auxiliary power supply Operating Temperature Range (2)(3) (400V standard) V three phase with neutral 50/60Hz From -30 C to +50 C Relative Humidity 0-95 % Installation Altitude (4) Certifications 3000 m above sea level Calculation report Safety and EMC standards CE, EN 50178, EN , EN , EN , EN , FCC part 15 Grid Standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI V1, CEI 0-16, Allegati A68 e A70 TERNA, CEI 0-21, IEEE1547, Arrêté , 659/2 Equipment Inverter versions BT POWER LV switchgear BT-AUX switchgear LV/MV transformer MV switchgear Internal lighting Emergency lighting Auxiliary power outlet Safety interlocks Fire safety kit MV safety kit Safety kit Support system M series (Multi MPPT) or X series (Master/Slave) One automatic switchgear for each inverter BASE version (FULL version optional) Dry type cast resin Protection cells 1P or 1P-2L 2 x 28 W fluorescent lamps 2 x 36 W fluorescent lamps (220V standard) V single phase 50/60Hz AREL security lock for LV/MV transformer compartment door 5 Kg CO 2 fire extinguisher Class 3 insulated gloves and 30 kv insulated footboard First aid kit and signals n. 8 30x30 cm brackets Mechanical Details Structure material Insulation Steel Sandwich panels containing a 50 mm rigid fire-proof polyurethane foam filling Notes: (1) Consumption inverter ventilation system included. (2) Rated output power indicated in the Technical Characteristics tables is guaranteed up to 45 C operating temperature. Derating above 45 C of 1.8% for each C of increase until 50 C operating temperature. (3) Temperatures below -20 C, requires optional heater. (4) For altitudes above 1000 mt the nominal power temperature is derated of 4.5 C every 1000 mt. 26
27 CON20 Wing Layout double doors weather station pole extraction grids 2896 wing door intake air grids Wing door 9364 Inverter 1 lv/mv TransfoRMER BT aux BT Power MV CUBICLE Inverter 2 FANS (tot.6)
28 Power Station CON20 Wing Manholes layout not isolated earth cable 8000 concrete slab 300 mm double grid ø8 20x20 N 2 CONCRETE MANHOLE 120x60 (MT SECTION) concrete manhole 50x50 with its cover (mt section) mm concrete slab concrete manhole 50x50 (dc entry) concrete manhole 50x50 with its cover (dc entry) pipe ø160 for wiring cables PIPE Ø32 FOR EARTH CONNECTION pipe ø160 for wiring cables earth manhole 40x40 with its cover ground level concrete manhole 50x50 with its cover (mv section) concrete manhole 50x50 with its cover (dc entry) Plan view Recommended area for opening the doors and for maintenance of devices 8000 concrete slab 300 mm double grid ø8 20x20 earth manhole 40x40 with its cover concrete manhole 50x50 with its cover (dc entry) concrete manhole 50x50 with its cover (mt section) platea sm 40,00 CONCRETE mc 12,00 earth manhole 40x40 with its cover concrete manhole 50x50 with its cover (mv section) concrete manhole 50x50 with its cover (dc entry) 28
29 Foundation Left side view concrete slab 300 mm double grid ø8 20x20 ground level +50 mm concrete manhole 50x50 with its cover pipe ø160 for wiring cables Front view ground level +50 mm concrete slab 300 mm double grid ø8 20x20 concrete manhole 50x50 with its cover pipe ø160 for wiring cables 29
30 CON20 Tunnel Power Station Physical, Electrical and Environmental characteristics Number of power modules Cooling System Type Forced air cooling by thermally-controlled centrifugal fans IP54 Ventilated version Inverter compartment (1) Transformer compartment Air flow 6000 m3/h 6000 m3/h 6000 m3/h Power Consumption 1950 W 2770 W 3180 W Air flow 6000 m3/h 6000 m3/h 6000 m3/h Power Consumption Extraction and intake air grid 720 W 720 W 720 W Anti-rain model General Information Auxiliary power supply (400V standard) V three phase with neutral 50/60Hz Operating Temperature Range (2)(3) From -30 C to +50 C Relative Humidity 0-95 % Installation Altitude (4) 3000 m above sea level Certifications Calculation report Safety and EMC standards CE, EN 50178, EN , EN , EN , EN , FCC part 15 Grid Standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI V1, CEI 0-16, Allegati A68 e A70 TERNA, CEI 0-21, IEEE1547, Arrêté , 659/2 Equipment Inverter versions M series (Multi MPPT) or X series (Master/Slave) BT POWER LV switchgear One automatic switchgear for each inverter BT-AUX switchgear BASE version (FULL version optional) LV/MV transformer Dry type cast resin MV switchgear Protection cells 1P or 1P-2L Internal lighting 2 x 28 W fluorescent lamps Emergency lighting 2 x 36 W fluorescent lamps Auxiliary power outlet (220V standard) V single phase 50/60Hz Safety interlocks AREL security lock for LV/MV transformer compartment door Fire safety kit 5 Kg CO 2 fire extinguisher MV safety kit Class 3 insulated gloves and 30 kv insulated footboard Safety kit First aid kit and signals Support system Directly on raft foundation (n. 8 30x30 cm brackets optional) Mechanical Details Structure material Steel Insulation Sandwich panels containing a 50 mm rigid fire-proof polyurethane foam filling Notes: (1) Consumption inverter ventilation system included. (2) Ventilated version: rated output power indicated in the Technical Characteristics tables is guaranteed up to 45 C operating temperature. Derating above 45 C of 1.8% for each C of increase until 50 C operating temperature. (3) Temperatures below -20 C, requires optional heater. (4) For altitudes above 1000 mt the nominal power temperature is derated of 4.5 C every 1000 mt. 30
31 CON20 Tunnel Layout double doors extraction grids weather station pole intake air grids double doors MV CUBICLE lv/mv TransfoRMER FANS (tot.4) Inverter 6058 BT aux BT Power 2039 mm 31
32 Power Station CON20 Tunnel Manholes layout not isolated earth cable 8000 concrete slab 300 mm double grid ø8 20x20 pipe ø32 for earth connection N 2 concrete manhole 50x50 (dc entry) concrete slab size +55mm concrete manhole 50x50 with its cover (dc entry) concrete manhole 50x50 with its cover (mt section) 5000 pipe ø160 for wiring cables concrete manhole 50x50 N 2 concrete manhole 50x50 (mv section) pipe ø32 for earth connection pipe ø160 for wiring cables earth manhole 40x40 with its cover ground level concrete manhole 50x50 with its cover (dc entry) concrete manhole 50x50 with its cover (dc entry) Plan view Recommended area for opening the doors and for maintenance of devices earth manhole 40x40 with its cover concrete manhole 50x50 with its cover (mv section) concrete manhole 50x50 with its cover (dc entry) 4500 earth manhole 40x40 with its cover concrete manhole 50x50 with its cover (mv section) concrete manhole 50x50 with its cover (dc entry) 32
33 Foundation Left side view concrete slab 300 mm double grid ø8 20x20 ground level +50 mm concrete manhole 50x50 with its cover pipe ø160 for wiring cables Front view concrete slab 300 mm double grid ø8 20x20 ground level +50 mm concrete manhole 50x50 with its cover pipe ø160 for wiring cables 33
34 Power Station CON40 A technological solution designed to be marketed and installed all over the world at sites with particularly adverse environmental conditions. Thanks to its CSC RINA certification it can be shipped by sea to anywhere in the world. Ideal for extreme environmental conditions Its welded galvanized steel monoblock guarantees maximum mechanical strenght and durability. The container inverter area can optionally be equipped with an interior climate control system, using industrial air conditioners with a Free Cooling function (IP54 version) or air recirculation system (IP65 version). Perfect water resistance and thermal insulation The entire container exterior is galvanised and varnished with polyurethane enamel for maximum protection against adverse weather conditions. The walls and roof contain a 50 mm rigid fire-proof polyurethane foam feeling, to guarantee perfect water resistance and correct thermal insulation. Complete accessibility Thanks to its innovative design, all devices are readily accessible, thereby making it easier to inspect, maintain and repair the Ingecon Sun PowerStation CON40. The transformer compartment door is equipped with an Arel safety lock with a blocking code. Main Features Power from 300 to 2,300 kwp. Extremely compact design. Plug & play solution. Forced air cooling. Free Cooling air conditioning. Air recirculation conditioning. Available up to 36 kv. CSC RINA certification. Benefits Extremely versatile. High efficiency. Maximum returns on investment. Guarantee of quality. Electrical Protections Reverse polarity. Output short-circuits and overloads. DC breaker with door control. Efficiency Efficiency (%) Power Station Vdc= V DC fuses. AC thermal-magnetic breaker with door control. DC and AC voltage surge suppressors. Anti-islanding monitoring system with automatic disconnections. Insulation control. Emergency button. Disconnection system should the LV/MV transformer overheat. Power (kw) Emergency disconnection button, accessible from outside. 34
35 CON40 Tunnel Innovative ventilation system The internal temperature is controlled by a centrifugal fan system. A number of internal and external probes guarantee a constant ambient temperature. The incoming air is filtered through special grids mounted on the bottom of the walls. Optionally, the container can be ordered with an internal cooling system featuring a Free Cooling function (only in IP54 conditioned version), with an air conditioner sized for each of the inverters, and with the following functions: Pure Free Cooling Compressor in OFF mode. The outdoor air temperature is low and the conditioner operates like a ventilation system, with an air inflow and outflow. Assisted Free Cooling Compressor operates in ON-OFF mode. The outdoor air temperature is relatively low to allow operation in Free Cooling mode. However, it is not low enough to maintain the desired interior temperature. Cooling Compressor in ON mode. The system operates like a normal air conditioner. Optional equipment In addition to the standard features, each Ingecon Sun PowerStation can be supplied with the following options: Energy meter with GSM system for remote metering. LV/LV transformer for the power supply to the BT-AUX auxiliary services panel. UPS for auxiliary services. Ingecon Sun ComBox, centralised communication system with RS-485/USB/ ETHERNET interfaces. GSM/GPRS Modem. SCADA monitoring system. Start-up at the place of installation. Dimensions (mm) Dimensions Version CON40 Body dimensions [mm] LxDxH Overall dimensions with all doors open [mm] Foundation dimensions [mm]
36 CON40 Tunnel Power Station Physical, Electrical and Environmental characteristics Number of power modules Cooling System Type IP65 Conditioned version (RC) IP54 Conditioned version (AC) IP54 Ventilated version (FA) FA= Forced air cooling by thermally-controlled centrifugal fans - AC= Air conditioning with free cooling function - RC= Air conditioning with recirculation system Inverter Air flow 6000 m3/h 6000 m3/h 6000 m3/h m3/h m3/h m3/h m3/h compartment Power consumption (1) 1950 W 2770 W 3180 W 4720 W 5540 W 5950 W 6360 W Transformer Air flow 9000 m3/h 9000 m3/h 9000 m3/h 9000 m3/h 9000 m3/h 9000 m3/h 9000 m3/h compartment Power consumption 1080 W 1080 W 1080 W 1080 W 1080 W 1080 W 1080 W Extraction and intake air grids Anti-rain and sand trap model Inverter Air flow 3800 m3/h 3800 m3/h 3800 m3/h 7600 m3/h 7600 m3/h 7600 m3/h 7600 m3/h compartment Free Cooling Power consumption (1) 3030 W 3850 W 4260 W 6880 W 7700 W 8110 W 8520 W Cooling Inverter 17.8 kw 17.8 kw 17.8 kw 35.6 kw 35.6 kw 35.6 kw 35.6 kw capacity compartment Cooling functions Power W W W W W W W consumption (1) Transformer Air flow 9000 m3/h 9000 m3/h 9000 m3/h 9000 m3/h 9000 m3/h 9000 m3/h 9000 m3/h compartment Power consumption 1080 W 1080 W 1080 W 1080 W 1080 W 1080 W 1080 W Extraction and intake air grids Anti-rain and sand trap model Cooling Inverter 17.8 kw 17.8 kw 17.8 kw 35.6 kw 35.6 kw 35.6 kw 35.6 kw capacity compartment Cooling functions Power W W W W W W W consumption (1) Transformer Air flow 6000 m3/h 6000 m3/h 6000 m3/h 6000 m3/h 6000 m3/h 6000 m3/h 6000 m3/h compartment Power consumption 720 W 720 W 720 W 720 W 720 W 720 W 720 W Extraction and intake air grids Anti-rain and sand trap model General Information Auxiliary power supply Operating Temperature Range (2)(3) (400V standard) V three phase with neutral 50/60Hz from -30 C to +55 C Relative Humidity 0-95 % Installation Altitude (4) Certifications 3000 m above sea level Calculation report Safety and EMC standards CE, EN 50178, EN , EN , EN , EN , FCC part 15 Grid Standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI V1, CEI 0-16, Annexes A68 e A70 TERNA, CEI 0-21, IEEE1547, Arrêté , 659/2 Equipment Inverter versions BT POWER LV switchgear BT-AUX switchgear LV/MV transformer MV switchgear Internal lighting Emergency lighting Auxiliary power outlet Safety interlocks Fire safety kit MV safety kit Safety kit Support system M series (Multi MPPT) or X series (Master/Slave) One automatic switchgear for each inverter (optional parallel switchgear or disconnector) BASE version (FULL version optional) Dry type cast resin / oil insulated Protection cells 1P or 1P-2L 5 x 2 x 36 W fluorescent lamps 5 x 1 x 36 W fluorescent lamps (220V standard) V single phase 50/60Hz AREL security lock for LV/MV transformer compartment door 5 Kg CO 2 fire extinguisher Class 3 insulated gloves and 30 kv insulated footboard First aid kit and signals Directly on raft foundation Mechanical Details Structure material Steel Insulation Sandwich panels containing a 50 mm rigid fire-proof polyurethane foam filling Notes: (1) Consumption inverter ventilation system included. (2) Ventilated version: rated output power indicated in the Technical Characteristics tables is guaranteed up to 45 C operating temperature. Derating above 45 C of 1.8% for each C of increase until 50 C operating temperature. (3) Temperatures below -20 C, requires optional heater. (4) For altitudes above 1000 mt the nominal power temperature is derated of 4.5 C every 1000 mt. 36
37 CON40 Tunnel Layout DOUBLE DOORS INVERTER COMPARTMENT IP INTAKE AIR GRID AIR CONDITIONER CONDENSER INVERTER 1 INVERTER 2 HEATER EXCHANGER BT-POWER BT-AUX TRANSFORMER DOOR LV/MV MV CUBICLE TRANSFORMER MV COMPARTMENT DOOR IP65 IP54 DOUBLE DOORS INVERTER COMPARTMENT IP INVERTER 1 INVERTER 2 BT-POWER TRANSFORMER MV CUBICLE FANS (TOT. 7) BT-AUX DOORS MV COMPARTMENT DOORS 37
38 Power Station CON40 Tunnel Manholes layout CONCRETE MANHOLE 50X50 WITH ITS COVER (DC ENTRY) CONCRETE MANHOLE 50X50 WITH ITS COVER (DC ENTRY) CONCRETE SLAB 300mm DOUBLE GRID Ø8 20X20 not isolated earth cable +50 mm PIPE Ø32 FOR EARTH CONNECTION EARTH MANHOLE 40X40 WITH ITS COVER CONCRETE MANHOLE 120x60 WITH ITS COVER (MV SECTION) PIPE Ø160 FOR CABLES WIRING CONNECTION 5000 CONCRETE MANHOLE 50X50 WITH ITS COVER (MV SECTION) PIPE Ø32 FOR EARTH CONNECTION Ground level EARTH MANHOLE 40X40 WITH ITS COVER CONCRETE MANHOLE 50X50 WITH ITS COVER (DC ENTRY) IP65 version IP54 version PIPE Ø160 FOR CABLES WIRING CONNECTION CONCRETE MANHOLE 50X50 WITH ITS COVER (MV SECTION) Platea mq 70,00 cls mc 12,00 Plan view CONCRETE MANHOLE 50X50 WITH ITS COVER (DC ENTRY) Recommended area for opening the doors and for maintenance of devices EARTH MANHOLE 50X50 WITH ITS COVER CONCRETE MANHOLE 50X50 WITH ITS COVER (MV SECTION) CONCRETE MANHOLE 40X40 WITH ITS COVER CONCRETE MANHOLE 50X50 WITH ITS COVER (DC ENTRY) IP65 version IP54 version CONCRETE MANHOLE 50X50 WITH ITS COVER (MV SECTION) 38
39 Foundation Left side view Ground level +50 mm CONCRETE SLAB 300mm DOUBLE GRID Ø8 20X20 CONCRETE MANHOLE 50X50 WITH ITS COVER PIPE Ø160 FOR CABLES WIRING CONNECTION Front view IP65 CONCRETE SLAB 300mm DOUBLE GRID Ø8 20X20 Ground level +50 mm CONCRETE MANHOLE 50X50 WITH ITS COVER CONCRETE MANHOLE 50X50 WITH ITS COVER PIPE Ø160 FOR CABLES WIRING CONNECTION CONCRETE SLAB 300mm DOUBLE GRID Ø8 20X20 IP54 Ground level +50 mm CONCRETE MANHOLE 50X50 WITH ITS COVER CONCRETE MANHOLE 50X50 WITH ITS COVER PIPE Ø160 FOR CABLES WIRING CONNECTION 39
40 Power Station INTRO DATA SHEETS 40
41 M220 INVERTER SERIES MULTI-MPPT CONFIGURATION Technical Characteristics Model Ingecon Sun Power Max 275 M220 Indoor 410 M220 Indoor 550 M220 Indoor 275 M220 Indoor M220 Indoor 410 M220 Indoor M220 Indoor 410 M220 Indoor M220 Indoor 550 M220 Indoor M220 Indoor Input (DC) Recommended PV Array Power Range (1) kwp kwp kwp kwp kwp kwp kwp MPPT Voltage Range Max DC Voltage (2) V 1000 V Max DC Current 800 A 1200 A 1600 A 2000 A 2400 A 2800 A 3200 A DC Inputs DC Connection Type From below by means of telescopic trapdoors, connection on bars through D40 cable glands (max cable diameter 40 mm) Number of Power Modules Number of MPPT Input Protections (Inverter) Overvoltage protection DC switch Other protections DC Class II surge arresters with removable cartridge DC load circuit breaker with door control (for each independent module) DC fuses, DC contactor for PV array disconnection (for each independent module), DC insulation monitor, emergency pushbutton Output (AC) Rated AC Power (3) 275 kw kw 550 kw kw 825 kw kw 1100 kw Max AC Current (Low Voltage) 736 A 1104 A 1472 A 1840 A 2208 A 2576 A 2944 A Rated AC Voltage AC Frequency 3 x kv IT 50 / 60 Hz Cos Phi (4) 1 Adjustable Cos Phi ± 0.9 a Pnom THD (Total Harmonic Distortion) (4) < 3% AC Connection Type From below by means of telescopic trapdoor Output Protections (Inverter) Overvoltage protection AC switch Anti-islanding protection Other protections AC Class II surge arresters with removable cartridge AC thermal magnetic breaker (for each independent module, not available in DC models) Yes, with automatic disconnection AC output short-circuit and overvoltage protections Operating Performance (Inverter) Max Efficiency 98.1 % European Efficiency / CEC Efficiency 97.7 % / 97.3 % Power Consumption in Stand-by Mode (5) 60 W 90 W 120 W 150 W 180 W 210 W 240 W Night-time Consumption < 5 W < 5 W < 5 W < 10 W < 10 W < 10 W < 10 W Total Weight SHE15 5 t 5.5 t 6 t SHE t 6 t 7 t 8.5 t 9 t 9.5 t 10.5 t CON20 7 t 7.5 t 8.5 t 10 t 10.5 t 11 t 12 t CON40 10 t 11 t 11.5 t 13 t 13.5 t 14 t 15 t Notes: (1) Depending on the type of installation and geographical location. (2) Never to be exceeded. Consider the voltage increase of the VOC no-load voltage at low temperatures. (3) The rated AC power is guaranteed at the ambient temperature pointed in the technical specs. (4) For Pout > 25% of the rated power and voltage according to IEC (5) Power consumption from PV array (not including LV/MV transformer no-load losses). 41
42 Power Station M275 INVERTER SERIES MULTI-MPPT CONFIGURATION Technical Characteristics Model Ingecon Sun Power Max 350 M275 Indoor 520 M275 Indoor 695 M275 Indoor 350 M275 Indoor M275 Indoor 520 M275 Indoor M275 Indoor 520 M275 Indoor M275 Indoor 695 M275 Indoor M275 Indoor Input (DC) Recommended PV Array Power Range (1) kwp kwp kwp kwp kwp kwp kwp MPPT Voltage Range Max DC Voltage (2) V 1000 V Max DC Current 800 A 1200 A 1600 A 2000 A 2400 A 2800 A 3200 A DC Inputs DC Connection Type From below by means of telescopic trapdoors, connection on bars through D40 cable glands (max cable diameter 40 mm) Number of Power Modules Number of MPPT Input Protections (Inverter) Overvoltage protection DC switch Other protections DC Class II surge arresters with removable cartridge DC load circuit breaker with door control (for each independent module) DC fuses, DC contactor for PV array disconnection (for each independent module), DC insulation monitor, emergency pushbutton Output (AC) Rated AC Power (3) kw kw 693 kw kw kw kw 1386 kw Max AC Current (Low Voltage) 736 A 1104 A 1472 A 1840 A 2208 A 2576 A 2944 A Rated AC Voltage AC Frequency 3 x kv IT 50 / 60 Hz Cos Phi (4) 1 Adjustable Cos Phi ± 0.9 a Pnom THD (Total Harmonic Distortion) (4) < 3% AC Connection Type From below by means of telescopic trapdoor Output Protections (Inverter) Overvoltage protection AC switch Anti-islanding protection Other protections AC Class II surge arresters with removable cartridge AC thermal magnetic breaker (for each independent module, not available in DC models) Yes, with automatic disconnection AC output short-circuit and overvoltage protections Operating Performance (Inverter) Max Efficiency 98.5 % European Efficiency / CEC Efficiency 98.2 % / 97.7 % Power Consumption in Stand-by Mode (5) 60 W 90 W 120 W 150 W 180 W 210 W 240 W Night-time Consumption < 5 W < 5 W < 5 W < 10 W < 10 W < 10 W < 10 W Total Weight SHE15 5 t 5.5 t 6.5 t SHE20 6 t 6.5 t 7.5 t 9 t 9.5 t 10 t 11 t CON20 7 t 7.5 t 8.5 t 10 t 10.5 t 11.5 t 12 t CON t 11 t 12 t 13.5 t 14 t 14.5 t 15.5 t Notes: (1) Depending on the type of installation and geographical location. (2) Never to be exceeded. Consider the voltage increase of the VOC no-load voltage at low temperatures. (3) The rated AC power is guaranteed at the ambient temperature pointed in the technical specs. (4) For Pout > 25% of the rated power and voltage according to IEC (5) Power consumption from PV array (not including LV/MV transformer no-load losses). 42
43 M300 INVERTER SERIES MULTI-MPPT CONFIGURATION Technical Characteristics Model Ingecon Sun Power Max 380 M300 Indoor 570 M300 Indoor 760 M300 Indoor 380 M300 Indoor M300 Indoor 570 M300 Indoor M300 Indoor 570 M300 Indoor M300 Indoor 760 M300 Indoor M300 Indoor Input (DC) Recommended PV Array Power Range (1) kwp kwp kwp kwp kwp kwp kwp MPPT Voltage Range Max DC Voltage (2) V 1000 V Max DC Current 800 A 1200 A 1600 A 2000 A 2400 A 2800 A 3200 A DC Inputs DC Connection Type From below by means of telescopic trapdoors, connection on bars through D40 cable glands (max cable diameter 40 mm) Number of Power Modules Number of MPPT Input Protections (Inverter) Overvoltage protection DC switch Other protections DC Class II surge arresters with removable cartridge DC load circuit breaker with door control (for each independent module) DC fuses, DC contactor for PV array disconnection (for each independent module), DC insulation monitor, emergency pushbutton Output (AC) Rated AC Power (3) kw 568 kw 757 kw kw 1136 kw 1325 kw 1514 kw Max AC Current (Low Voltage) 736 A 1104 A 1472 A 1840 A 2208 A 2576 A 2944 A Rated AC Voltage AC Frequency 3 x kv IT 50 / 60 Hz Cos Phi (4) 1 Adjustable Cos Phi ± 0.9 a Pnom THD (Total Harmonic Distortion) (4) < 3% AC Connection Type From below by means of telescopic trapdoor Output Protections (Inverter) Overvoltage protection AC switch Anti-islanding protection Other protections AC Class II surge arresters with removable cartridge AC thermal magnetic breaker (for each independent module, not available in DC models) Yes, with automatic disconnection AC output short-circuit and overvoltage protections Operating Performance (Inverter) Max Efficiency 98.6 % European Efficiency / CEC Efficiency 98.3 % / 97.8 % Power Consumption in Stand-by Mode (5) 60 W 90 W 120 W 150 W 180 W 210 W 240 W Night-time Consumption < 5 W < 5 W < 5 W < 10 W < 10 W < 10 W < 10 W Total Weight SHE15 5 t 5.5 t 6.5 t SHE20 6 t 6.5 t 7.5 t 9 t 9.5 t 10.5 t 11.5 t CON t 7.5 t 9 t 10 t 10.5 t 12 t 12.5 t CON t 11 t 12 t 13.5 t 14 t 15 t 16 t Notes: (1) Depending on the type of installation and geographical location. (2) Never to be exceeded. Consider the voltage increase of the VOC no-load voltage at low temperatures. (3) The rated AC power is guaranteed at the ambient temperature pointed in the technical specs. (4) For Pout > 25% of the rated power and voltage according to IEC (5) Power consumption from PV array (not including LV/MV transformer no-load losses). 43
44 Power Station M320 INVERTER SERIES MULTI-MPPT CONFIGURATION Technical Characteristics Model Ingecon Sun Power Max 400 M320 Indoor 605 M320 Indoor 800 M320 Indoor 400 M320 Indoor M320 Indoor 605 M320 Indoor M320 Indoor 605 M320 Indoor M320 Indoor 800 M320 Indoor M320 Indoor Input (DC) Recommended PV Array Power Range (1) kwp kwp kwp kwp kwp kwp kwp MPPT Voltage Range Max DC Voltage (2) V 1000 V Max DC Current 800 A 1200 A 1600 A 2000 A 2400 A 2800 A 3200 A DC Inputs DC Connection Type From below by means of telescopic trapdoors, connection on bars through D40 cable glands (max cable diameter 40 mm) Number of Power Modules Number of MPPT Input Protections (Inverter) Overvoltage protection DC switch Other protections DC Class II surge arresters with removable cartridge DC load circuit breaker with door control (for each independent module) DC fuses, DC contactor for PV array disconnection (for each independent module), DC insulation monitor, emergency pushbutton Output (AC) Rated AC Power (3) kw 602 kw 803 kw kw 1210 kw 1408 kw 1606 kw Max AC Current (Low Voltage) 736 A 1104 A 1472 A 1840 A 2208 A 2576 A 2944 A Rated AC Voltage AC Frequency 3 x kv IT 50 / 60 Hz Cos Phi (4) 1 Adjustable Cos Phi ± 0.9 a Pnom THD (Total Harmonic Distortion) (4) < 3% AC Connection Type From below by means of telescopic trapdoor Output Protections (Inverter) Overvoltage protection AC switch Anti-islanding protection Other protections AC Class II surge arresters with removable cartridge AC thermal magnetic breaker (for each independent module, not available in DC models) Yes, with automatic disconnection AC output short-circuit and overvoltage protections Operating Performance (Inverter) Max Efficiency 98.7 % European Efficiency / CEC Efficiency 98.4 % / 97.7 % Power Consumption in Stand-by Mode (5) 60 W 90 W 120 W 150 W 180 W 210 W 240 W Night-time Consumption < 5 W < 5 W < 5 W < 10 W < 10 W < 10 W < 10 W Total Weight SHE15 5,5 t 6 t 7 t SHE20 6 t 7 t 8 t 9.5 t 9.5 t 10.5 t 11.5 t CON t 8 t 9 t 10.5 t 11 t 11.5 t 12.5 t CON t 11 t 12 t 14 t 14.5 t 15 t 16 t Notes: (1) Depending on the type of installation and geographical location. (2) Never to be exceeded. Consider the voltage increase of the VOC no-load voltage at low temperatures. (3) The rated AC power is guaranteed at the ambient temperature pointed in the technical specs. (4) For Pout > 25% of the rated power and voltage according to IEC (5) Power consumption from PV array (not including LV/MV transformer no-load losses). 44
45 M345 INVERTER SERIES MULTI-MPPT CONFIGURATION Technical Characteristics Model Ingecon Sun Power Max 440 M345 Indoor 660 M345 Indoor 880 M345 Indoor 440 M345 Indoor M345 Indoor 660 M345 Indoor M345 Indoor 660 M345 Indoor M345 Indoor 880 M345 Indoor M345 Indoor Input (DC) Recommended PV Array Power Range (1) kwp kwp kwp kwp kwp kwp kwp MPPT Voltage Range Max DC Voltage (2) V 1000 V Max DC Current 800 A 1200 A 1600 A 2000 A 2400 A 2800 A 3200 A DC Inputs DC Connection Type From below by means of telescopic trapdoors, connection on bars through D40 cable glands (max cable diameter 40 mm) Number of Power Modules Number of MPPT Input Protections (Inverter) Overvoltage protection DC switch Other protections DC Class II surge arresters with removable cartridge DC load circuit breaker with door control (for each independent module) DC fuses, DC contactor for PV array disconnection (for each independent module), DC insulation monitor, emergency pushbutton Output (AC) Rated AC Power (3) 440 kw 660 kw 880 kw 1100 kw 1320 kw 1540 kw 1760 kw Max AC Current (Low Voltage) 736 A 1104 A 1472 A 1840 A 2208 A 2576 A 2944 A Rated AC Voltage AC Frequency 3 x kv IT 50 / 60 Hz Cos Phi (4) 1 Adjustable Cos Phi ± 0.9 a Pnom THD (Total Harmonic Distortion) (4) < 3% AC Connection Type From below by means of telescopic trapdoor Output Protections (Inverter) Overvoltage protection AC switch Anti-islanding protection Other protections AC Class II surge arresters with removable cartridge AC thermal magnetic breaker (for each independent module, not available in DC models) Yes, with automatic disconnection AC output short-circuit and overvoltage protections Operating Performance (Inverter) Max Efficiency 98.8 % European Efficiency / CEC Efficiency 98.5 % / 98 % Power Consumption in Stand-by Mode (5) 60 W 90 W 120 W 150 W 180 W 210 W 240 W Night-time Consumption < 5 W < 5 W < 5 W < 10 W < 10 W < 10 W < 10 W Total Weight SHE t 6 t 7 t SHE20 6 t 6.5 t 7.5 t 9.5 t 10 t 10.5 t 11.5 t CON t 8 t 9 t 10.5 t 11 t 12 t 13 t CON t 11 t 12 t 14 t 14.5 t 15.5 t 16 t Notes: (1) Depending on the type of installation and geographical location. (2) Never to be exceeded. Consider the voltage increase of the VOC no-load voltage at low temperatures. (3) The rated AC power is guaranteed at the ambient temperature pointed in the technical specs. (4) For Pout > 25% of the rated power and voltage according to IEC (5) Power consumption from PV array (not including LV/MV transformer no-load losses). 45
46 Power Station M360 INVERTER SERIES MULTI-MPPT CONFIGURATION Technical Characteristics Model Ingecon Sun Power Max 460 M360 Indoor 690 M360 Indoor 920 M360 Indoor 460 M360 Indoor M360 Indoor 690 M360 Indoor M360 Indoor 690 M360 Indoor M360 Indoor 920 M360 Indoor M360 Indoor Input (DC) Recommended PV Array Power Range (1) kwp kwp kwp kwp kwp kwp kwp MPPT Voltage Range Max DC Voltage (2) V 1000 V Max DC Current 800 A 1200 A 1600 A 2000 A 2400 A 2800 A 3200 A DC Inputs DC Connection Type From below by means of telescopic trapdoors, connection on bars through D40 cable glands (max cable diameter 40 mm) Number of Power Modules Number of MPPT Input Protections (Inverter) Overvoltage protection DC switch Other protections DC Class II surge arresters with removable cartridge DC load circuit breaker with door control (for each independent module) DC fuses, DC contactor for PV array disconnection (for each independent module), DC insulation monitor, emergency pushbutton Output (AC) Rated AC Power (3) 458 kw 688 kw 917 kw 1146 kw 1376 kw 1605 kw 1834 kw Max AC Current (Low Voltage) 736 A 1104 A 1472 A 1840 A 2208 A 2576 A 2944 A Rated AC Voltage AC Frequency 3 x kv IT 50 / 60 Hz Cos Phi (4) 1 Adjustable Cos Phi ± 0.9 a Pnom THD (Total Harmonic Distortion) (4) < 3% AC Connection Type From below by means of telescopic trapdoor Output Protections (Inverter) Overvoltage protection AC switch Anti-islanding protection Other protections AC Class II surge arresters with removable cartridge AC thermal magnetic breaker (for each independent module, not available in DC models) Yes, with automatic disconnection AC output short-circuit and overvoltage protections Operating Performance (Inverter) Max Efficiency 98.8 % European Efficiency / CEC Efficiency 98.6 % / 98.1 % Power Consumption in Stand-by Mode (5) 60 W 90 W 120 W 150 W 180 W 210 W 240 W Night-time Consumption < 5 W < 5 W < 5 W < 10 W < 10 W < 10 W < 10 W Total Weight SHE15 5,5 t 6 t 7 t SHE20 6 t 6.5 t 7.5 t 9.5 t 10 t 10.5 t 11.5 t CON t 8 t 9 t 10.5 t 11 t 12 t 13 t CON40 10,5 t 11t 12 t 14 t 14.5 t 15.5 t 16 t Notes: (1) Depending on the type of installation and geographical location. (2) Never to be exceeded. Consider the voltage increase of the VOC no-load voltage at low temperatures. (3) The rated AC power is guaranteed at the ambient temperature pointed in the technical specs. (4) For Pout > 25% of the rated power and voltage according to IEC (5) Power consumption from PV array (not including LV/MV transformer no-load losses). 46
47 M400 INVERTER SERIES MULTI-MPPT CONFIGURATION Technical Characteristics Model Ingecon Sun Power Max 500 M400 Indoor 750 M400 Indoor 1000 M400 Indoor 500 M400 Indoor M400 Indoor 750 M400 Indoor M400 Indoor 750 M400 Indoor M400 Indoor 1000 M400 Indoor M400 Indoor Input (DC) Recommended PV Array Power Range (1) kwp kwp kwp kwp kwp kwp kwp MPPT Voltage Range Max DC Voltage (2) V 1000 V Max DC Current 800 A 1200 A 1600 A 2000 A 2400 A 2800 A 3200 A DC Inputs DC Connection Type From below by means of telescopic trapdoors, connection on bars through D40 cable glands (max cable diameter 40 mm) Number of Power Modules Number of MPPT Input Protections (Inverter) Overvoltage protection DC switch Other protections DC Class II surge arresters with removable cartridge DC load circuit breaker with door control (for each independent module) DC fuses, DC contactor for PV array disconnection (for each independent module), DC insulation monitor, emergency pushbutton Output (AC) Rated AC Power (3) 510 kw 765 kw 1019 kw 1275 kw 1530 kw 1784 kw 2038 kw Max AC Current (Low Voltage) 736 A 1104 A 1472 A 1840 A 2208 A 2576 A 2944 A Rated AC Voltage AC Frequency 3 x kv IT 50 / 60 Hz Cos Phi (4) 1 Adjustable Cos Phi ± 0.9 a Pnom THD (Total Harmonic Distortion) (4) < 3% AC Connection Type From below by means of telescopic trapdoor Output Protections (Inverter) Overvoltage protection AC switch Anti-islanding protection Other protections AC Class II surge arresters with removable cartridge AC thermal magnetic breaker (for each independent module, not available in DC models) Yes, with automatic disconnection AC output short-circuit and overvoltage protections Operating Performance (Inverter) Max Efficiency 98.8 % European Efficiency / CEC Efficiency 98,6 % - 98,1 % Power Consumption in Stand-by Mode (5) 60 W 90 W 120 W 150 W 180 W 210 W 240 W Night-time Consumption < 5 W < 5 W < 5 W < 10 W < 10 W < 10 W < 10 W Total Weight SHE t 6 t 7 t SHE20 6 t 6.5 t 7.5 t 9.5 t 10 t 10.5 t 12 t CON t 8 t 9 t 10.5 t 11 t 12 t 13 t CON t 11 t 12 t 14 t 14.5 t 15.5 t 16.5 t Notes: (1) Depending on the type of installation and geographical location. (2) Never to be exceeded. Consider the voltage increase of the VOC no-load voltage at low temperatures. (3) The rated AC power is guaranteed at the ambient temperature pointed in the technical specs. (4) For Pout > 25% of the rated power and voltage according to IEC (5) Power consumption from PV array (not including LV/MV transformer no-load losses). 47
48 Power Station X220 INVERTER SERIES MASTER/SLAVE CONFIGURATION Technical Characteristics Model Ingecon Sun Power Max 275 X220 Indoor 410 X220 Indoor 550 X220 Indoor 275 X220 Indoor X220 Indoor 410 X220 Indoor X220 Indoor 410 X220 Indoor X220 Indoor 550 X220 Indoor X220 Indoor Input (DC) Recommended PV Array Power Range (1) kwp kwp kwp kwp kwp kwp kwp MPPT Voltage Range Max DC Voltage (2) V 1000 V Max DC Current 800 A 1200 A 1600 A 2000 A 2400 A 2800 A 3200 A DC Inputs DC Connection Type From below by means of telescopic trapdoors, connection on bars through D40 cable glands (max cable diameter 40 mm) Number of Power Modules Number of MPPT Input Protections (Inverter) Overvoltage protection DC switch Other protections DC Class II surge arresters with removable cartridge DC load circuit breaker with door control (for each independent module) DC fuses, DC contactor for PV array disconnection (for each independent module), DC insulation monitor, emergency pushbutton Output (AC) Rated AC Power (3) 275 kw kw 550 kw kw 825 kw kw 1100 kw Max AC Current (Low Voltage) 736 A 1104 A 1472 A 1840 A 2208 A 2576 A 2944 A Rated AC Voltage AC Frequency 3 x kv IT 50 / 60 Hz Cos Phi (4) 1 Adjustable Cos Phi ± 0.9 a Pnom THD (Total Harmonic Distortion) (4) < 3% AC Connection Type From below by means of telescopic trapdoor Output Protections (Inverter) Overvoltage protection AC switch Anti-islanding protection Other protections AC Class II surge arresters with removable cartridge AC thermal magnetic breaker (for each independent module, not available in DC models) Yes, with automatic disconnection AC output short-circuit and overvoltage protections Operating Performance (Inverter) Max Efficiency 98.1 % European Efficiency / CEC Efficiency 97.9 % / 97.4 % Power Consumption in Stand-by Mode (5) 60 W 90 W 120 W 150 W 180 W 210 W 240 W Night-time Consumption < 5 W < 5 W < 5 W < 10 W < 10 W < 10 W < 10 W Total Weight SHE15 5 t 5.5 t 6.5 t SHE t 6t 7 t 8.5 t 9 t 9.5 t 10.5 t CON20 7 t 7.5 t 8.5 t 9.5 t 10 t 10.5 t 11.5 t CON40 10 t 10.5 t 11.5 t 13 t 13.5 t 14 t 15 t Notes: (1) Depending on the type of installation and geographical location. (2) Never to be exceeded. Consider the voltage increase of the VOC no-load voltage at low temperatures. (3) The rated AC power is guaranteed at the ambient temperature pointed in the technical specs. (4) For Pout > 25% of the rated power and voltage according to IEC (5) Power consumption from PV array (not including LV/MV transformer no-load losses). 48
49 X275 INVERTER SERIES MASTER/SLAVE CONFIGURATION Technical Characteristics Model Ingecon Sun Power Max 350 X275 Indoor 520 X275 Indoor 695 X275 Indoor 350 X275 Indoor X275 Indoor 520 X275 Indoor X275 Indoor 520 X275 Indoor X275 Indoor 695 X275 Indoor X275 Indoor Input (DC) Recommended PV Array Power Range (1) kwp kwp kwp kwp kwp kwp kwp MPPT Voltage Range Max DC Voltage (2) V 1000 V Max DC Current 800 A 1200 A 1600 A 2000 A 2400 A 2800 A 3200 A DC Inputs DC Connection Type From below by means of telescopic trapdoors, connection on bars through D40 cable glands (max cable diameter 40 mm) Number of Power Modules Number of MPPT Input Protections (Inverter) Overvoltage protection DC switch Other protections DC Class II surge arresters with removable cartridge DC load circuit breaker with door control (for each independent module) DC fuses, DC contactor for PV array disconnection (for each independent module), DC insulation monitor, emergency pushbutton Output (AC) Rated AC Power (3) kw kw 693 kw kw kw kw 1386 kw Max AC Current (Low Voltage) 736 A 1104 A 1472 A 1840 A 2208 A 2576 A 2944 A Rated AC Voltage AC Frequency 3 x kv IT 50 / 60 Hz Cos Phi (4) 1 Adjustable Cos Phi ± 0.9 a Pnom THD (Total Harmonic Distortion) (4) < 3% AC Connection Type From below by means of telescopic trapdoor Output Protections (Inverter) Overvoltage protection AC switch Anti-islanding protection Other protections AC Class II surge arresters with removable cartridge AC thermal magnetic breaker (for each independent module, not available in DC models) Yes, with automatic disconnection AC output short-circuit and overvoltage protections Operating Performance (Inverter) Max Efficiency 98.5 % European Efficiency / CEC Efficiency 98.3 % / 97.8 % Power Consumption in Stand-by Mode (5) 60 W 90 W 120 W 150 W 180 W 210 W 240 W Night-time Consumption < 5 W < 5 W < 5 W < 10 W < 10 W < 10 W < 10 W Total Weight SHE15 5 t 5.5 t 6.5 t SHE20 6 t 6.5 t 7.5 t 9 t 9 t 10 t 11 t CON20 7 t 7.5 t 8.5 t 10 t 10.5 t 11.5 t 12 t CON40 10 t 11 t 12 t 13.5 t 14 t 14.5 t 15.5 t Notes: (1) Depending on the type of installation and geographical location. (2) Never to be exceeded. Consider the voltage increase of the VOC no-load voltage at low temperatures. (3) The rated AC power is guaranteed at the ambient temperature pointed in the technical specs. (4) For Pout > 25% of the rated power and voltage according to IEC (5) Power consumption from PV array (not including LV/MV transformer no-load losses). 49
50 Power Station X300 INVERTER SERIES MASTER/SLAVE CONFIGURATION Technical Characteristics Model Ingecon Sun Power Max 380 X300 Indoor 570 X300 Indoor 760 X300 Indoor 380 X300 Indoor X300 Indoor 570 X300 Indoor X300 Indoor 570 X300 Indoor X300 Indoor 760 X300 Indoor X300 Indoor Input (DC) Recommended PV Array Power Range (1) kwp kwp kwp kwp kwp kwp kwp MPPT Voltage Range Max DC Voltage (2) V 1000 V Max DC Current 800 A 1200 A 1600 A 2000 A 2400 A 2800 A 3200 A DC Inputs DC Connection Type From below by means of telescopic trapdoors, connection on bars through D40 cable glands (max cable diameter 40 mm) Number of Power Modules Number of MPPT Input Protections (Inverter) Overvoltage protection DC switch Other protections DC Class II surge arresters with removable cartridge DC load circuit breaker with door control (for each independent module) DC fuses, DC contactor for PV array disconnection (for each independent module), DC insulation monitor, emergency pushbutton Output (AC) Rated AC Power (3) kw 568 kw 757 kw kw 1136 kw 1325 kw 1514 kw Max AC Current (Low Voltage) 736 A 1104 A 1472 A 1840 A 2208 A 2576 A 2944 A Rated AC Voltage AC Frequency 3 x kv IT 50 / 60 Hz Cos Phi (4) 1 Adjustable Cos Phi ± 0.9 a Pnom THD (Total Harmonic Distortion) (4) < 3% AC Connection Type From below by means of telescopic trapdoor Output Protections (Inverter) Overvoltage protection AC switch Anti-islanding protection Other protections AC Class II surge arresters with removable cartridge AC thermal magnetic breaker (for each independent module, not available in DC models) Yes, with automatic disconnection AC output short-circuit and overvoltage protections Operating Performance (Inverter) Max Efficiency 98.6 % European Efficiency / CEC Efficiency 98.4 % / 97.9 % Power Consumption in Stand-by Mode (5) 60 W 90 W 120 W 150 W 180 W 210 W 240 W Night-time Consumption < 5 W < 5 W < 5 W < 10 W < 10 W < 10 W < 10 W Total Weight SHE t 5.5 t 6.5 t SHE20 6 t 6.5 t 7.5 t 9 t 9.5 t 10.5 t 11.5 t CON t 7.5 t 8.5 t 10 t 10.5 t 11.5 t 12.5 t CON t 11 t 12 t 13.5 t 14 t 15 t 16 t Notes: (1) Depending on the type of installation and geographical location. (2) Never to be exceeded. Consider the voltage increase of the VOC no-load voltage at low temperatures. (3) The rated AC power is guaranteed at the ambient temperature pointed in the technical specs. (4) For Pout > 25% of the rated power and voltage according to IEC (5) Power consumption from PV array (not including LV/MV transformer no-load losses). 50
51 X320 INVERTER SERIES MASTER/SLAVE CONFIGURATION Technical Characteristics Model Ingecon Sun Power Max 400 X320 Indoor 605 X320 Indoor 800 X320 Indoor 400 X320 Indoor X320 Indoor 605 X320 Indoor X320 Indoor 605 X320 Indoor X320 Indoor 800 X320 Indoor X320 Indoor Input (DC) Recommended PV Array Power Range (1) kwp kwp kwp kwp kwp kwp kwp MPPT Voltage Range Max DC Voltage (2) V 1000 V Max DC Current 800 A 1200 A 1600 A 2000 A 2400 A 2800 A 3200 A DC Inputs DC Connection Type From below by means of telescopic trapdoors, connection on bars through D40 cable glands (max cable diameter 40 mm) Number of Power Modules Number of MPPT Input Protections (Inverter) Overvoltage protection DC switch Other protections DC Class II surge arresters with removable cartridge DC load circuit breaker with door control (for each independent module) DC fuses, DC contactor for PV array disconnection (for each independent module), DC insulation monitor, emergency pushbutton Output (AC) Rated AC Power (3) kw 602 kw 803 kw kw 1210 kw 1408 kw 1606 kw Max AC Current (Low Voltage) 736 A 1104 A 1472 A 1840 A 2208 A 2576 A 2944 A Rated AC Voltage AC Frequency 3 x kv IT 50 / 60 Hz Cos Phi (4) 1 Adjustable Cos Phi ± 0.9 a Pnom THD (Total Harmonic Distortion) (4) < 3% AC Connection Type From below by means of telescopic trapdoor Output Protections (Inverter) Overvoltage protection AC switch Anti-islanding protection Other protections AC Class II surge arresters with removable cartridge AC thermal magnetic breaker (for each independent module, not available in DC models) Yes, with automatic disconnection AC output short-circuit and overvoltage protections Operating Performance (Inverter) Max Efficiency 98.7 % European Efficiency / CEC Efficiency 98,5 % - 97,9 % Power Consumption in Stand-by Mode (5) 60 W 90 W 120 W 150 W 180 W 210 W 240 W Night-time Consumption < 5 W < 5 W < 5 W < 10 W < 10 W < 10 W < 10 W Total Weight SHE t 5.5 t 6.5 t SHE20 6 t 6.5 t 7.5 t 9.5 t 9.5 t 10.5 t 11.5 t CON t 8 t 9 t 10.5 t 11 t 11.5 t 12.5 t CON t 11 t 12 t 14 t 14.5 t 15 t 16 t Notes: (1) Depending on the type of installation and geographical location. (2) Never to be exceeded. Consider the voltage increase of the VOC no-load voltage at low temperatures. (3) The rated AC power is guaranteed at the ambient temperature pointed in the technical specs. (4) For Pout > 25% of the rated power and voltage according to IEC (5) Power consumption from PV array (not including LV/MV transformer no-load losses). 51
52 Power Station X345 INVERTER SERIES MASTER/SLAVE CONFIGURATION Technical Characteristics Model Ingecon Sun Power Max 440 X345 Indoor 660 X345 Indoor 880 X345 Indoor 440 X345 Indoor X345 Indoor 660 X345 Indoor X345 Indoor 660 X345 Indoor X345 Indoor 880 X345 Indoor X345 Indoor Input (DC) Recommended PV Array Power Range (1) kwp kwp kwp kwp kwp kwp kwp MPPT Voltage Range Max DC Voltage (2) V 1000 V Max DC Current 800 A 1200 A 1600 A 2000 A 2400 A 2800 A 3200 A DC Inputs DC Connection Type From below by means of telescopic trapdoors, connection on bars through D40 cable glands (max cable diameter 40 mm) Number of Power Modules Number of MPPT Input Protections (Inverter) Overvoltage protection DC switch Other protections DC Class II surge arresters with removable cartridge DC load circuit breaker with door control (for each independent module) DC fuses, DC contactor for PV array disconnection (for each independent module), DC insulation monitor, emergency pushbutton Output (AC) Rated AC Power (3) 440 kw 660 kw 880 kw 1100 kw 1320 kw 1540 kw 1760 kw Max AC Current (Low Voltage) 736 A 1104 A 1472 A 1840 A 2208 A 2576 A 2944 A Rated AC Voltage AC Frequency 3 x kv IT 50 / 60 Hz Cos Phi (4) 1 Adjustable Cos Phi ± 0.9 a Pnom THD (Total Harmonic Distortion) (4) < 3% AC Connection Type From below by means of telescopic trapdoor Output Protections (Inverter) Overvoltage protection AC switch Anti-islanding protection Other protections AC Class II surge arresters with removable cartridge AC thermal magnetic breaker (for each independent module, not available in DC models) Yes, with automatic disconnection AC output short-circuit and overvoltage protections Operating Performance (Inverter) Max Efficiency 98.8 % European Efficiency / CEC Efficiency 98.6 % / 98 % Power Consumption in Stand-by Mode (5) 60 W 90 W 120 W 150 W 180 W 210 W 240 W Night-time Consumption < 5 W < 5 W < 5 W < 10 W < 10 W < 10 W < 10 W Total Weight SHE t 5.5 t 6.5 t SHE20 6 t 6.5 t 7.5 t 9.5 t 10 t 10.5 t 11.5 t CON t 8 t 9 t 10.5 t 11 t 12 t 13 t CON t 11 t 12 t 14 t 14.5 t 15.5 t 16 t Notes: (1) Depending on the type of installation and geographical location. (2) Never to be exceeded. Consider the voltage increase of the VOC no-load voltage at low temperatures. (3) The rated AC power is guaranteed at the ambient temperature pointed in the technical specs. (4) For Pout > 25% of the rated power and voltage according to IEC (5) Power consumption from PV array (not including LV/MV transformer no-load losses). 52
53 X360 INVERTER SERIES MASTER/SLAVE CONFIGURATION Technical Characteristics Model Ingecon Sun Power Max 460 X360 Indoor 690 X360 Indoor 920 X360 Indoor 460 X360 Indoor X360 Indoor 690 X360 Indoor X360 Indoor 690 X360 Indoor X360 Indoor 920 X360 Indoor X360 Indoor Input (DC) Recommended PV Array Power Range (1) kwp kwp kwp kwp kwp kwp kwp MPPT Voltage Range Max DC Voltage (2) V 1000 V Max DC Current 800 A 1200 A 1600 A 2000 A 2400 A 2800 A 3200 A DC Inputs DC Connection Type From below by means of telescopic trapdoors, connection on bars through D40 cable glands (max cable diameter 40 mm) Number of Power Modules Number of MPPT Input Protections (Inverter) Overvoltage protection DC switch Other protections DC Class II surge arresters with removable cartridge DC load circuit breaker with door control (for each independent module) DC fuses, DC contactor for PV array disconnection (for each independent module), DC insulation monitor, emergency pushbutton Output (AC) Rated AC Power (3) 458 kw 688 kw 917 kw 1146 kw 1376 kw 1605 kw 1834 kw Max AC Current (Low Voltage) 736 A 1104 A 1472 A 1840 A 2208 A 2576 A 2944 A Rated AC Voltage AC Frequency 3 x kv IT 50 / 60 Hz Cos Phi (4) 1 Adjustable Cos Phi ± 0.9 a Pnom THD (Total Harmonic Distortion) (4) < 3% AC Connection Type From below by means of telescopic trapdoor Output Protections (Inverter) Overvoltage protection AC switch Anti-islanding protection Other protections AC Class II surge arresters with removable cartridge AC thermal magnetic breaker (for each independent module, not available in DC models) Yes, with automatic disconnection AC output short-circuit and overvoltage protections Operating Performance (Inverter) Max Efficiency 98.8 % European Efficiency / CEC Efficiency 98.7 % / 98.1 % Power Consumption in Stand-by Mode (5) 60 W 90 W 120 W 150 W 180 W 210 W 240 W Night-time Consumption < 5 W < 5 W < 5 W < 10 W < 10 W < 10 W < 10 W Total Weight SHE t 5.5 t 6.5 t SHE20 6 t 6.5 t 7.5 t 9.5 t 10 t 10.5 t 11.5 t CON t 8 t 9 t 10.5 t 11 t 12 t 12.8 t CON t 11.5 t 12.5 t 14 t 14.5 t 15.5 t 16.5 t Notes: (1) Depending on the type of installation and geographical location. (2) Never to be exceeded. Consider the voltage increase of the VOC no-load voltage at low temperatures. (3) The rated AC power is guaranteed at the ambient temperature pointed in the technical specs. (4) For Pout > 25% of the rated power and voltage according to IEC (5) Power consumption from PV array (not including LV/MV transformer no-load losses). 53
54
55 Accessories
56 Power Station Remote control and monitoring optionals INGEPAC PL70FV Relay PI This Kit is composed by all the devices necessary for voltage and frequency grid protection according with CEI016 standard. Ingepac PL70FV relay provide RS 485 Modbus RTU, Ethernet interface with protocol IEC GOOSE and automatic reclosing function. Fiscal meter Kit The fiscal meter kit is composed by a fiscal meter and its voltage and current transformer. It allows to record the energy produced from the PV plant. It could be provided with RS485 communication and modem GSM for remote monitoring. It is also available for double or more measuring system, depending on the plant s features. Gateway Ingesys Gateway solutions offer both data concentrator and protocol converter features as well as advanced features to perform logical simple operation using the collected data. Ingesys Gateway can be easily configured through its user-friendly configuration tool. This tool offers a wide range of features to facilitate the definition of the protocol models and profiles, together with online monitoring option to optimize commissioning and maintenance tasks. SCADA Remote control enables real time operation and supervision of the PV installations and is an essential tool for guaranteeing the highest level of availability. It is adapted to the requirements of each installation and can incorporate new features based on modular SCADA architecture. It is scalable and flexible thanks to its OPC based client/server architecture. The Remote Controller can integrate the Substation and any other device that may be remotely controlled. It is compatible with a multitude of protocols and supports (ADSL, RDSI, GSM, GPRS, Internet, fiber optics, radio, microwaves and satellite). 56
57 Remote control and monitoring optionals String Control The Ingecon Sun String Control is a device for measuring each PV array string current and detecting defective string currents. String currents can be monitored by means of RS485, GSM/GPRS, Ethernet or Wireless communication boards. It is easy to mount and suitable for outdoor installations thanks to its IP65 protection class. ComBox The Ingecon Sun ComBox allows remote communication with the inverters in a number of standards, thanks to its versatility to jointly process data coming from Ethernet, RS485, GSM/GPRS, wireless or Bluetooth networks. The Ingecon Sun ComBox includes analogue input data storage and reading functions for the measurement of meteorological variables. Manager The Ingecon Sun Manager is a PC software operating in a Windows graphical environment allowing PV plants management and monitoring. It allows the integration of three phase inverters installed inside the power station with string control devices in a single plant and multiple PV plants management from a single PC. Communication can be realized by means of RS485, GSM/GPRS and Ethernet communication boards. Monitor The Ingecon SUN Monitor web portal provides access to a PV plant equipped with Ethernet or GPRS connection from any PC with an Internet connection. Its ease of access facilitates owner, installer or promoter plant control. This software provides information about the PV plant status and production, either in list and graphic format or through an ed production report. The data recording and storage are made throughout the entire inverter service life. 57
58 Power Station BT-POWER Low Voltage Parallel Switchgear The BT-POWER low voltage parallel switchgear allows connecting the inverters of the Ingecon Sun Power Station to the LV/MV step-up transformer. Upon request, it can be supplied with voltage transformers and current transformers for fiscal energy metering. Moreover, it can also be equipped with a circuit breaker operating as an interface device, if a LV interface protection is required, or with a manual disconnector. Standard functions: Automatic circuit breaker for each inverter (800 to 1600A) Current-operated release coil (for backup function) Functions available upon request: Manual switch disconnector General motorized circuit breaker from 1600 A to 3200 A Current-operated release coil (for backup function) Minimum voltage coil (as interface protection device) RS485 communication system for the motorized switch Measurement module on motorized switch Voltage transformer (VT) and current transformer (CT) for fiscal energy metering 58
59 BT-POWER Low Voltage Parallel Switchgear 59
60 Power Station BT-AUX BASE Auxiliary Services Switchgear The BT-AUX BASE auxiliary services switchgear is an added value for the Ingecon Sun PowerStation since it makes it unnecessary to implement any further wiring for the operation and monitoring of the additional equipment. Besides the wide range of standard functions, other options can be requested when ordering the product. Standard functions: General circuit breaker on the power supply of the BT-AUX BASE switchgear. Class II surge arresters with removable cartridge. AC/DC 24V power supply for the auxiliary circuits of the instruments and monitoring devices. Fuses and contactors on the power supply of the Ingecon Sun Power Station ventilation system, which is automatically powered only under specific thermal conditions. Fuses on the power supply of the BT POWER switchgear auxiliary services. Fuses on the power supply of the Inverter auxiliary services. Fuses on the power supply of the MV switchgear auxiliary services. Residual current device on the power supply of the internal lighting system and power outlets. Fuses on the UPS power supply (UPS excluded) Fuses on the power supply of the BT- POWER privileged circuits; Fuses on the power supply of the Ingecon Sun Combox and monitoring system; Fuses on the power supply of the privileged circuits of the Inverters; RS485 Modbus RTU network with DAT3590 signal amplifier (x2 DAT3590 for Ingecon Sun Power Station with number of Power Blocks 5) Ready for the implementation of a NT154 or NT935 thermometric control unit (NT538 in case of transformers with double secondary winding) for the protection of the MV transformer, including: MV line disconnection in case of overheating; Alarm contact wired to the terminal board; RS485 Modbus RTU serial communication. Ready for the implementation of a 1000Vdc insulation detector on the secondary winding of the MV transformer (x2 for transformers with double secondary winding): Light indicator on the front of the boards; Alarm contact wired to the terminal board. Functions available upon request: NT154 or NT935 thermometric control unit (NT538 in case of transformers with double secondary winding). LV/LV transformer for the powering of the auxiliary switchgear BT-AUX BASE Vdc insulation detector on the secondary winding of the MV transformer (x2 for transformers with double secondary winding). UPS for auxiliary services. 60
61 BT-AUX BASE Auxiliary Services Switchgear 61
62 Power Station BT-AUX FULL Auxiliary Services Switchgear The BT-AUX FULL auxiliary services switchgear is an added value for the Ingecon Sun Power Station since it makes it unnecessary to implement any further wiring for the operation and monitoring of the additional equipment. Besides the wide range of standard functions, other options can be requested when ordering the product. Standard functions: General circuit breaker on the power supply of the BT-AUX FULL switchgear. Class II surge arresters with removable cartridge. AC/DC 24V power supply for the aux circuits of the instruments and monitoring devices. Circuit breakers and contactors on the power supply of the Ingecon Sun Power Station cooling system, which is automatically powered only under specific thermal conditions. Circuit breaker on the power supply of the BT- POWER switchgear auxiliary services. Circuit breakers on the power supply of the Inverter auxiliary services. Circuit breaker on the power supply of the MV switchgear auxiliary services. Three-phase backup circuit breaker. Residual current device on the power supply of the internal lighting system and power outlets. Three-phase residual current device on the UPS power supply (UPS excluded); Circuit breaker on the power supply to the BT-POWER privileged circuits; Circuit breaker on the power supply of the Ingecon Sun Combox and monitoring system; Circuit breaker on the power supply of the Inverters privileged circuits; x2 single-phase backup circuit breakers RS485 Modbus RTU network with DAT3590 signal amplifier (x2 DAT3590 for Ingecon Sun Power Station with number of Power Blocks 5) Ready for the implementation of a NT935 thermometric control unit (NT538 in case of transformers with double secondary winding) for the protection of the MV transformer, including: MV line disconnection in case of overheating; Alarm contact wired to the terminal board; RS485 Modbus RTU serial communication. Ready for the implementation of a VRT200 control unit managing the cooling fans of the MV transformer, including: Fans fault detection; alarm contact wired to the terminal board. Ready for the implementation of a 1000Vdc insulation detector on the secondary winding of the MV transformer (x2 for transf. with double sec.winding): Light indicator on the front of the boards; alarm contact wired to the terminal board. Ready for the implementation of an interface relay for CEI 0-16 function: x1 RS485 Modbus RTU interface; x1 Ethernet interface - IEC protocol; Automatic reset system. Functions available upon request: NT935 thermometric control unit (NT538 in case of transformers with double secondary winding). VRT200 control unit for the control of the cooling fans of the MV transformer. LV/LV transformer for the powering of the auxiliary switchgear BT-AUX FULL Vdc insulation detector on the secondary winding of the MV transformer (x2 for transformers with double secondary winding). UPS for auxiliary services. Energy fiscal meter with GSM system for remote monitoring (x2 for transformers with double secondary winding). Energy fiscal meter for the auxiliary services with GSM system for the remote monitoring, with voltage and current measurement transformers. RS485 Modbus RTU communication module for energy fiscal metering. Interface relay for CEI 0-16 function, with open delta voltage measurement on MV side, via voltage transformer or sensors. 62
63 BT-AUX FULL Auxiliary Services Switchgear 63
64 Power Station Medium Voltage Transformer Cast resin Ingeteam provides highly performing LV/MV three phase dry type transformers, with epoxy resin vacuum cast windings. Power ratings are available up to 2 MVA, with voltage ratings (MV side) from 10 up to 24 kva (up to 36 kva on the Ingecon Sun Power Station CON40). The transformers are F1-C2-E2 classified as per the CEI EN standard, offering the following benefits: Self-extinguishing, with low smoke emission (F1); Resistance to climatic variations (C2); Resistance to humidity and atmospheric pollution (E2); Reduced maintenance needs; Flexibility: no foundations required, easy handling. The voltage value at the secondary winding (LV side) is compatible with the inverter output voltage: 220 V, 275 V, 300 V, 320 V, 345 V, 360 V, 400V; Double windings transformers available. Standard functions: Standard losses; Electrostatic shield reducing disturbances, distortions and overvoltages. Functions available upon request: Reduced losses; CEI-EN Forced ventilation; Copper windings. Medium Voltage Transformer Category Rated frequency Cast-resin transformer 50 / 60Hz Primary voltage regulator ± 2 x 2.5 % Insulation class Primary winding 12 kv: 12 / 28 / 75 kv 17,5 kv: 17,5 / 38 / 95 kv 24 kv: 24 / 50 / 125 kv 36 kv (1) : 36 / 70 / 170kV Secondary winding 1.1/3 kv Primary / secondary conductive material Primary / secondary winding protection Vector group Primary connection Secondary connection Aluminium / Aluminium (Copper optional) Cast resin / Resin impregnated Dyn11 Delta Star + Neutral Environmental, climatic and fire classes E2 / C2 / F1 (CESI certification as per the new standard IEC year 2004) Thermal class Max overtemperature for primary / secondary windings Installation Cooling type Cooling system (optional) Altitude above sea level (2) Short-circuit impedance at 75 C Partial discharge level General features F / F 100 / 100 K Indoor Natural air Forced ventilation 1000 m 6% (24kV) 10 pc x3 terminal boards for primary voltage adjustment (5 positions), x4 LV connection plates, x2 earthing terminal boards, x2 lifting lugs, x4 rotating wheels, x1 connection box, x3 PT100 temperature probes, electrostatic shield. Notes: (1) CON40 models only. - (2) For Higher altitudes, please contact Ingeteam. 64
65 24 kv CLASS Single winding Cast resin standard losses RS Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a) Cast resin reduced losses RR Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a) Double winding Cast resin standard losses RS Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a) Cast resin reduced losses RR Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a)
66 Power Station 36 kv CLASS Single winding Cast resin standard losses RS Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a) Cast resin reduced losses RR Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a) Double winding Cast resin standard losses RS Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a) Cast resin reduced losses RR Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a)
67 Medium voltage transformer ermetic oil insulated Ingeteam provides highly performing LV/MV three phase oil insulated type transformers. Power ratings are available up to 2 MVA, with voltage ratings (MV side) from 10 up to 24 kva (up to 36 kva on the Ingecon Sun Power Station CON40). The transformers are classified as per the CEI 14-4 and EN standard, offering the following benefits: Low losses ready in standard model, reduced losses model available; Reduced maintenance needs; Flexibility: no foundations required, easy handling. Suitable both for internal or external use; The voltage value at the secondary winding (LV side) is compatible with the inverter output voltage: 220 V, 275 V, 300 V, 320 V, 345 V, 360 V, 400V; Double windings transformers available. Standard functions: Standard losses; Electrostatic shield reducing disturbances, distortions and overvoltages. Functions available upon request: Reduced losses; CEI-EN Copper windings. Medium Voltage Transformer Category Rated frequency Ermetic oil insulated transformer 50 / 60Hz Primary voltage regulator ± 2 x 2.5 % Insulation class Primary winding 12 kv: 12 / 28 / 75 kv 17,5 kv: 17,5 / 38 / 95 kv 24 kv: 24 / 50 / 125 kv 36 kv (1) : 36 / 70 / 170 kv Secondary winding 1.1/3 kv Primary / secondary conductive material Vector group Primary connection Secondary connection Max overtemperature for primary / secondary windings Installation Cooling type Altitude above sea level (2) Short-circuit impedance at 75 C General features Notes: (1) CON40 models only. - (2) For Higher altitudes, please contact Ingeteam. Aluminium / Aluminium (Copper optional) Dyn11 Delta Star + Neutral 60 / 65 K indoor or outdoor ONAN 1000 m 6% (24kV) Terminal board for primary voltage adjustment, Lifting lugs, Tow hooks, RIS device, x2 earthing terminal, x4 rotating wheels, 1x thermoweel, 1x wasted oil valve, electrostatic shield, 1x wasted oil tank. 67
68 Power Station 24 kv CLASS Single winding Oil standard losses OS Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a) Oil reduced losses OR Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a) Double winding Oil standard losses OS Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a) Oil reduced losses OR Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a)
69 36 kv CLASS Single winding Oil standard losses OS Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a) Oil reduced losses OR Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a) Double winding Oil standard losses OS Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a) Oil reduced losses OR Electrical specifications Power kva No-load loss W Load loss (75 C) W Impedance Voltage (75 C) % No-load current (75 C) % Sound level LwA db(a) Sound level LpA db(a)
70 Power Station Medium Voltage Switchgear Standard Features: 24 kv rated voltage (up to 36 kv for CON40). Voltage 50Hz: 50 kv. Pulse voltage: 125 kv (up to 170 kv for CON40). Bar bus rated current: 630 A. Short time current (1s): 16 ka. Resistance to internal arc for 0.7s: 16 ka. Cut-off power: 16 ka. Inspection door. Door locking. Relative Humidity: 0-90 %. Altitude above sea level: max 1000 m (1). Features available upon request: Anti-condensation heater. Internal lighting system. Voltage transformer (VT) for voltage measurement. Notes: (1) For Higher altitudes, please contact Ingeteam. 70
71 Type SF-L SF-L-M Load break switch disconnector with fuses and earth disconnector + outgoing line (1P 1L). Star configuration Load break switch disconnector with fuses and earth disconnector + outgoing line + voltage measurement (CEI 0-16) (1P 1L). Star configuration Description Type SF1-LS-LS SF1-L-LS Motorized load break switch disconnector with fuses and earth disconnector + 2 line with load break switch disconnector and earth disconnector (1P 2L). Ring or chain configuration Motorized load break switch disconnector with fuses and earth disconnector + 1 incoming line + 1 outgoing line with load break switch disconnector and earth disconnector (1P 2L). Ring or chain configuration Description 71
72 Power Station Type E2 L E2 L-M Automatic motorized circuit breaker with functions 50, 51 and 51N CEI 0-16 and earth disconnector + outgoing line (1P 1L). Star configuration Automatic motorized circuit breaker with 50, 51 and 51N CEI 0-16 and earth disconnector + outgoing line + voltage measurement (CEI 0-16) (1P 1L). Star configuration Type E2-LS-LS E2-L-LS Automatic motorized circuit breaker with 50, 51 and 51N functions and earth disconnector + 2 line with load break switch disconnector and earth disconnector (1P 2L). Ring or chain configuration Automatic motorized circuit breaker with functions 50, 51 and 51N and earth disconnector + 1 incoming line + 1 outgoing line with load break switch disconnector and earth disconnector (1P 2L). Ring or chain configuration Description Description 72
73 Type E21-L E22-L Automatic motorized circuit breaker functions 50, 51 and 51N CEI 0-16 with CT and VT for energy metering and earth disconnector + outgoing riser (1P 1L). Star configuration Automatic motorized circuit breaker with functions 50, 51 and 51N, interface protection CEI 0-16 and earth disconnector + voltage measurement (CEI 0-16) + outgoing line (1P 1L). Star configuration Description Type E23-L E3 L Automatic motorized circuit breaker functions 50, 51 and 51N, interface protection CEI 0-16 with CT and VT for energy metering and earth disconnector + voltage measurement (CEI 0-16) + outgoing line (1P 1L). Star configuration Automatic motorized circuit breaker with functions 50, 51, 51N and 67N CEI 0-16 and earth disconnector + outgoing line (1P 1L). Star configuration Description 73
74 Type Power Station Type E3-LS1-LS1 SF1-LS1-E3 Automatic motorized circuit breaker with functions 50, 51, 51N and 67N CEI 0-16 and earth disconnector + 2 line with load break switch disconnector and earth disconnector (1P 2L). Motorized load break switch disconnector with fuses and earth disconnector + 1 incoming line with load break switch disconnector and earth disconnector + automatic motorized circuit breaker with functions 50, 51, 51N and 67N CEI 0-16 and earth disconnector (1P 2L). Ring or chain configuration Ring or chain configuration Type E31 L E32 L Automatic motorized circuit breaker with functions 50,51,51N,67N CEI 016 and earth disconnector + energy metering + outgoing line (1P1L) Star configuration Automatic motorized circuit breaker with functions 50,51,51N,67N CEI 016 and earth disconnector + functions 27,59,81 Interface Protection CEI016 A70 + outgoing line (1P1L) Star configuration Description Description 74
75 Type E33 L E22 L2 Automatic motorized circuit breaker with functions 50,51,51N,67N CEI 016 and earth disconnector + functions 27,59,81 Interface Protection CEI016 A70 and energy metering + outgoing line (1P1L) Automatic motorized circuit breaker with functions 50,51,51N,67N CEI 016 and earth disconnector + functions 27,59,81 Interface Protection CEI016 A70 + outgoing line with surge arrester (1P1L) Star configuration Star configuration Type E32 L2 E33 L2 Automatic motorized circuit breaker with functions 50,51,51N,67N CEI 016 and earth disconnector + functions 27,59,81 Interface Protection CEI016 A70 + outgoing line with surge arrester (1P1L) Automatic motorized circuit breaker with functions 50,51,51N,67N CEI 016 and earth disconnector + functions 27,59,81 Interface Protection CEI016 A70 and energy metering + outgoing line with surge arrester. (1P1L) Star configuration Star configuration Description Description 75
76 Power Station Coding Example: Ingecon Sun Power Station SHE20W FA 2000 M B32 POWER STATION type SHELTER 15' SHELTER 20' SHE 15 W SHE 20 T SHE 20 W CONTAINER 20' CON 20 T CON 20 W CON 20 RT CON 20 RW CONTAINER 40' CON 40 RT W= wing doors, T= standard doors, R= CSC RINA certified POWER STATION cooling Forced air Air conditioning Recirculation conditioning FA AC RC POWER STATION size Total inverter power (AC) INVERTER Ingecon Sun Power Max Multi MPPT Master/Slave M220 M400 X220 X360 Power Block INVERTER Number of Power Block MPPT INVERTER Number of MPPT INVERTER inputs Number of inverter inputs F(n )=couple of fuses per input A B(n )=couple of fuses every four inputs 550A F8 F32 B8 B32 76
77 CB2 0 F RS SF-L MV switchgear not present 0 Example code SF-L See pages 70 to 75 for details Legend L Line Incoming L2 Line + Arrester LS Line Switch disconnector/earth LS1 Line Switch disconnector/earth Motorized LS2 Line Switch disconnector/earth + Arrester SF Switch disconnector with Fuses SF1 Switch disconnector with Fuses Motorized M Switch disconnector with Fuses and Voltage Transformer E2 Circuit Breaker func. 50/51/51N CEI016 E3 Circuit Breaker func. 50/51/51N/67N CEI016 E21 Circuit Breaker func. 50/51/51N CEI016, energy metering E31 Circuit Breaker func. 50/51/51N/67N CEI016, energy metering E22 Circuit Breaker func. 50/51/51N-27/59/81 CEI016 E32 Circuit Breaker func. 50/51/51N/67N-27/59/81 CEI016 E23 Circuit Breaker func. 50/51/51N-27/59/81 CEI016, energy metering E33 Circuit Breaker func. 50/51/51N/67N-27/59/81 CEI016, energy metering MV transformer Resin standard losses Resin reduced losses Oil standard losses Oil reduced losses RS RR OS OR MV transformer Voltage kv MV transformer Power kva BT AUX auxiliary services switchgear B= Base model B F= Full model F BT POWER disconnection device, MV transformer side 0= not present 0 CB= automatic circuit breaker CB SD= switch disconnector SD BT POWER parallel switchgear BT POWER inputs quantity CB(n )= automatic circuit breaker A 0...CB2 77
78 Power Station Basic wiring diagrams Ingecon Sun Power Station Multi MPPT configuration Ingecon Sun Power Station Master/Slave configuration 78
79
80 Ingeteam Power Technology, S.A. Avda. Ciudad de la Innovación, SARRIGUREN (Navarra) - Spain Tel.: / Fax.: [email protected] Ingeteam S.r.l. Via Emilia Ponente, CASTEL BOLOGNESE (RA) - Italy Tel.: / Fax.: [email protected] Ingeteam GmbH Herzog-Heinrich-Str MUNICH - Germany Tel.: / Fax.: [email protected] Ingeteam SAS Parc Innopole BP rue Carmin - Le Naurouze B5 F Toulouse Labège cedex - France Tel: +33 (0) / Fax: +33 (0) [email protected] Ingeteam INC Great American Parkway, Suite 320 SANTA CLARA, CA USA Tel.: +1 (408) / Fax.: +1 (408) [email protected] Ingeteam INC W. Canal St. MILWAUKEE, WI USA Tel.: +1 (414) / +1 (855) Fax.: +1 (414) [email protected] Ingeteam, a.s. Technologická 371/ OSTRAVA - PUSTKOVEC Czech Republic Tel.: / Fax.: [email protected] Ingeteam Shanghai, Co. Ltd. Shanghai Trade Square, Si Ping Road SHANGHAI - P.R. China Tel / Fax.: [email protected] Ingeteam, S.A. de C. V. Ave. Revoluciòn, nº 643 Local 9 Colonia Jardin Español - MONTERREY NUEVO LEÓN - Mexico Tel.: / Fax.: [email protected] Ingeteam Ltda. Rua Luiz Carlos Brunello, 286 Chácara Sao Bento VALINHOS SP - Brazil Tel.: / Fax.: [email protected] Ingeteam Pty Ltd. 2 Alphen Square South16th Road Midrand South Africa Tel.: / Fax.: [email protected] Ingeteam SpA Bandera, 883 Piso Santiago de Chile - Chile Tel [email protected] Ingeteam Pvt. Ltd. Level 4 Augusta Point Golf Course Road, Sector Gurgaon - India Tel.: / Fax.: [email protected] Ingeteam Sp. z o.o. UI. Koszykowa 60/62 m Warszawa - Poland Tel.: / Fax.: [email protected] Ingeteam Power Technology, S.A. Ref: 02/2013 rev: 5 Information subject to change without notice
ABB central inverters PVS800 100 to 1000 kw
Solar inverters ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and
ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw
Solar inverters ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw ABB s central inverters are extremely scalable, modular-inverter systems that are based on 55kW modular
Re-defining the utility-scale inverter
Re-defining the utility-scale inverter We believe in green energy in the ability to meet and contribute to growing power demands while supporting a smart grid that serves a smart society. Solution at a
RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.
RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER tgood.com Energy. Fast. TGOOD is a world leading manufacturer of prefabricated renewable energy substations PRODUCT CONCEPT ENVIRONMENTAL
ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw
Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw PV energy, combined with energy storage systems, can help increase self-consumption and energy selfsufficiency*. One of the biggest challenges
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors
APPENDIX APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS RJ12 connectors Pin # 1 Signal Name Not Used 2 +TR Description + Data Line 3 +R Remote OFF Required or Remote OFF control 4 -TR 5 Not Used 6 RTN -
PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:
PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV
SolarMax P series The power package for residential solar plants
SolarMax P series The power package for residential solar plants The future-proof solution The requirements for residential photovoltaic plants have increased continuously in the past years. Due to our
ABB turnkey stations ULTRA-MVC-S 770 to 3110 kw
Solar inverters ABB turnkey stations LTRA-MC-S 770 to 3110 k Turnkey solutions comprising an LTRA series inverter and a Medium oltage Compartment (MC-S). The new LTRA-MC-S has been specifically developed
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Fronius IG Plus. The next generation grid-connected PV inverter
Fronius IG Plus The next generation grid-connected PV inverter Maximum energy harvest cloudy or clear The first complete inverter solution. Reliable. Proven. Smart. An outstanding addition to the family:
ABB micro inverters MICRO-0.25/0.3-I-OUTD, CDD and accessories 250 to 300 W
Solar inverters ABB micro inverters MICRO-0.25/0.3-I-OUTD, CDD and accessories 250 to 300 W MICRO The ABB MICRO inverter system is the perfect solution suitable for photovoltaic applications when flexibility
2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams 3000. Sunteams 4000 Sunteams 5000
Photovoltaic Inverter Specification Version 2.06 1500 2000 3000 4000 5000 Kinglong New Energy Technology Co.Ltd. Kinglong New Energy Technology Co.Ltd. specification 1.1. Introduction... 3 1.1.1. Environment...
e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN
e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN We create ideas with power! ELEKTROMETAL ENERGETYKA SA is a new Polish company providing solutions for electrical power engineering. Our services
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
Photovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET
FOR IMMEDIATE RELEASE No. 2387 Product & Catalogue Inquiries: Media Contact Naoto Shimada Travis Woodward Nakatsugawa Works Public Relations Department Photovoltaic Power System Business Center Mitsubishi
DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.
Oil & Gas Energy Catalogue DC UPS RTB.e 50-1000 A 3 phase rectifier battery chargers voltage: 400 Vac, 3-phase, 50/60 Hz voltage: 24/48/110/220 Vdc RMB.e/RCB.e 50-100-150 A 1 and 3 phase compact rectifier
ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management
Energy Depot GmbH Delivering Solutions for Energy Management PRODUCT AND APPLICATION GUIDE Total Monitoring Solution for PV SOLAR LOGGER & ANALYSIS DC STRING MONITORING Residential Comprehensive Solar
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
MAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
Innovation Powers Efficiency
Innovation Powers Efficiency REFU Solar Electronics REFU Solar Electronics REFU Solar Electronics, Inc., the U.S. subsidiary of REFUSOL GmbH, provides sales, customer support, service, application engineering
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
vacon 8000 solar inverter a driving force in solar energy
vacon 8000 solar inverter a driving force in solar energy a driving force in renewable energy Vacon was founded in Vaasa, Finland in 1993. It has a long history of producing high-quality inverters, power
Your own power station: For continuous power
Mass Combi Ultra Your own power station: For continuous power Compact and lightweight inverter/battery charger Seamless switching between generator and grid Separate second charger Integrated MPPT solar
SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with
SOLAR MICRO INVERTER 260 COMMUNICATI GATEWAY Apparent Power Control (APC) P Q unique micro inverter with REAL & REACTIVE POWER CTROL 2 Micro Inverters unique micro inverter with real & reactive power control
YSmart Technology Co.,Ltd
YSmart Technology Co.,Ltd GWV Series Grid Tie Microinverter User Manual The copyright of this user manual belong to YSmart TechnologyCompany Limited. Without the written permission of the copyright holder,
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
4.0 UPS dedicated to ICT for unmatched energy savings
4.0 UPS dedicated to ICT for unmatched energy savings Introducing UPSaver by Borri, a new modular UPS series for the ICT industry, totally configurable, quickly scalable, with high efficiency and low TCO.
AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
Failure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw
,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted
Manual. Solar Fountain Mobile Phone Charger
EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements NATUS switchgear systems your advantages minimal use of insulant
TECHNICAL DESCRIPTION OF THE DISTRIBUTION SUBSTATION REMOTE MONITORING SYSTEM
HELLENIC ELECTRICITY DISTRIBUTION NETWORK OPERATOR S.A. NOTICE OF CALL FOR TENDERS No ND-xxx PROJECT: Pilot Telemetering and Management System for the Electric Power Supply Demand by Residential and Small
How To Make A Fronius Cl Power Inverter
Fronius CL PV central inverter with Fronius MIX concept Modular system. Maximum yield. The Fronius CL combines high-yield power electronics with the unique, modular system design of up to 15 identical
Green Energy Solutions
Green Energy Solutions Power Electronics for Photovoltaic Inverter Systems 1 Energy Management Product Line-up Energy Management Product Line-up Power Conversion and Stabilization Frequency Converter Static
REGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM
ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM MAKING SMART TOWNS, BUILDING SMART COMMUNITIES WHY PANASONIC? RESIDENTIAL STORAGE BATTERY SYSTEM The next evolution in solar energy solutions. Panasonic
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
INVERTER SYSTEM PRODUCT BROCHURE
INVERTER SYSTEM PRODUCT BROCHURE DC AC the SolaX inverter The solar inverter is a critical technological component that is the heart of any PV plant. A solar inverter, or PV inverter, converts the variable
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy
Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility
Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
Galaxy VM. Three-phase power protection. schneider-electric.com
Galaxy VM Three-phase power protection schneider-electric.com 2 schneider-electric.com schneider-electric.com 3 Galaxy VM trusted partner for your business continuity Features and benefits Highly efficient,
BB800 Off-Grid Solar System
BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry
Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation
Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation Index News Introduction Applications & Segments Main Components Applicable Standards Technical characteristics
Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W
T5 TC-DEL TC-SEL TC-TEL TC-DD PC BASIC, 4 28 W Electronic ballast for system output < 25 W Product description CELMA Energy Efficiency Index A2 / A3 Nominal life time up to 50,000 h (at ta 50 C with a
ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
HYBRID POWER SYSTEMS for TELECOM applications
HYBRID POWER SYSTEMS HYBRID POWER SYSTEMS HYBRID POWER SYSTEM WITH AC GENSET PRAMAC has developed a new solution that allow coupling a traditional AC constant speed diesel genset with an energy storage
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
Solar Inverters Product Catalogue. Solar inverters, monitoring and support for residential / commercial installations and power plants
Solar Inverters Product Catalogue Solar inverters, monitoring and support for residential / commercial installations and power plants EU Content About us 2 SOLIVIA - Solar inverters 4 Solar inverters
Charge Controller CC611/CC612 Preliminary datasheet
Preliminary datasheet Preliminary datasheet CC61x_D00xxx_00_D_XXE_preliminary/04.2015 Product description The ender charge controller CC611 is the main component of a charging point and is designed for
MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution
UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,
The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity
Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings
We develop the technology for a blue sky...
We develop the technology for a blue sky... MAVİSİS TECHNOLOGY Mavisis Technology A.Ş. is a leader technology company in power electronics area in renewable energy. Mavisis Technology, as a brand, states
DCS Series 1 kw, 1.2 kw, & 3 kw
DCS Series 1 kw, 1.2 kw, & 3 kw AVAILABLE WITH LXI STANDARD COMPLIANT ETHERNET Applications Automotive Electronics Rackmount ATE System Battery Charging DCS Series DCS Series: 1 kw, 1.2 kw, & 3 kw DCS
Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS
+ Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
PSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1
User Manual Hybrid 1KW-5KW INVERTER / CHARGER Version: 1.1 Table of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Product Overview... 3 INSTALLATION...
Technical data UNIBLOCK UBSF 180 625
Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
Modular Systems wind portfolio overview Power Collection and Grid Connection products
Modular Systems wind portfolio overview Power Collection and Grid Connection products Slide 1 Modular Systems wind portfolio Wind power - definition A wind turbine is a device that converts kinetic energy
What are the basic electrical safety issues and remedies in solar photovoltaic installations?
What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
Checklist Testing and inspection without interconnection
Shams Dubai Checklist Testing and inspection without interconnection Version.0 AUGUST 205 TABLE OF CONTENTS Scope...5. PV PLANT AND INSPECTION DATA... 6 2 TESTING EQUIPMENT...7 3 DOCUMENTS... 8 3. Reference
COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C
COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing
White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5
White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code June 2015 Revision 1.5 Shalhevet Bar-Asher; SolarEdge Technologies, Inc. Bill Brooks, PE; Brooks Engineering LLC
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
How can a charging station for electric vehicles be set up simply and safely?
SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,
victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850
victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850 SECTIONS ENGLISH 1 NEDERLANDS 27 DEUTSCH 55 This page intentionally left blank. ENGLISH USER MANUAL Victron Atlas
FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
JSI Series Single Phase String Inverter. Features. Typical Efficiency Curve JSI-1500TL JSI-2000TL JSI-2500TL
JSI Series Single Phase String Inverter Features JSI-500TL JSI-000TL JSI-500TL High performance string inverters ØFrom.5KW to 6.0KW ØWide PV input voltage range ØRapid MPPT tracking technology ØSuperior
Emergency lighting units EM powerled
M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year
CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN
CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN 5.1 Introduction So far in the development of this research, the focus has been to estimate the available insolation at a particular location on the earth s surface
32VFD Variable Frequency Drives for Centrifugal Chillers
32VFD 32VFD Variable Frequency Drives for Centrifugal Chillers ENERGY-SAVING CONTROL FOR CENTRIFUGAL CHILLERS Reduce energy consumption in your existing centrifugal chiller Your chiller was specified to
Specification guide no. 9 Active harmonic conditioner from 20 to 480 A
Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable
THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012
Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
Number 1 in efficiency
PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why
High Power Programmable DC Power Supplies PVS Series
Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient
/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE
Perfect Welding Solar Energy Perfect Charging FRONIUS ENERGY PACKAGE The personal storage solution for 24H Sun. PC board replacement process SnapINverter technology Integrated data communication Dynamic
14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.
G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable