Installation Manual Multi Function Display MFD8/MFD12
|
|
|
- Angel Norton
- 9 years ago
- Views:
Transcription
1 Installation Manual Multi Function Display MFD8/MFD12 SAFETY INSTRUCTIONS...i SYSTEM CONFIGURATION... ii EQUIPMENT LISTS... iv 1. MOUNTING Mounting Considerations Flush Mounting Desktop Mounting WIRING SETTING UP THE EQUIPMENT Setup for Single MFD in the Network Setup for Multiple MFDs in the Network...25 PACKING LISTS... A-1 OUTLINE DRAWINGS... D-1 INTERCONNECTION DIAGRAM... S-1
2
3 SAFETY INSTRUCTIONS The user and installer must read the appropriate safety instructions before attempting to install or operate the equipment. WARNING CAUTION Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Warning, Caution Mandatory Action Prohibitive Action WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment unless totally familiar with electrical circuits. Only qualified personnel should work inside the equipment. Turn off the power at the switchboard before beginning the installation. Fire or electrical shock can result if the power is left on. Be sure that the power supply is compatible with the voltage rating of the equipment. Connection of an incorrect power supply can cause fire or damage the equipment. MFD8 MFD12 CAUTION Ground the equipment to prevent electrical shock and mutual interference. Use the proper fuse. Use of an incorrect fuse may damage the equipment. Observe the following compass safe distances to prevent interference to a magnetic compass: Standard compass Steering compass 0.90 m 0.60 m 0.85 m 0.55 m i
4 SYSTEM CONFIGURATION MFD8 RADAR SENSOR DRS2D/DRS4D RADAR SENSOR DRS4A/DRS6A/DRS12A/DRS25A OR POWER SUPPLY UNIT* 1 PSU-012 or PSU VDC* 2 AIS RECEIVER, HEADING SENSOR or EXTERNAL BUZZER GPS NAVIGATOR GP-320B/330B USB DEVICE (MOUSE, KYBD) NMEA 2000 (GP-330B, ETC.) *1 PSU-012: w/drs4a/6a/12a PSU-013: w/drs25a MULTI FUNCTION DISPLAY MFD VDC* 2 * 2 See the figure below for rectifiers used in the system. MONITOR MU-155C/170C, etc. VIDEO IN(CCD CAMERA, MAX. 2) LINE OUT (SPKR, ETC.) LINE IN(MIC, FUTURE USE) HUB -101 FISH FINDER (DFF series, ETR-6/10N, ETR-30N, FCV-1150) : Standard Supply : Optional Supply : Local Supply FAX-30 FA- 50 Rectifiers used in the system DRS2D/4D MFD8 RU-3423 DRS4A/6A/ 12A PSU-012 MFD8 PR-62 DRS4A/6A/ 12A/25A PSU-012/013 MFD8 RU-1746B RU-3423 DRS25A PSU-013 MFD8 PR-62 RU-1746B ii
5 MFD12 RADAR SENSOR DRS2D/DRS4D RADAR SENSOR DRS4A/DRS6A/DRS12A/DRS25A OR POWER SUPPLY UNIT* 1 PSU-012 or PSU VDC* 2 AIS RECEIVER, HEADING SENSOR or EXTERNAL BUZZER GPS NAVIGATOR GP-320B/330B USB DEVICE (MOUSE, KYBD) NMEA 2000 (GP-330B, ETC.) *1 PSU-012: w/drs12a PSU-013: w/drs25a MULTI FUNCTION DISPLAY MFD12 * 2 See the table and figure below for rectifiers used in the system VDC* 2 Rectifiers used in the system MONITOR MU-155C/170C, etc. VIDEO IN (CCD CAMERA, MAX. 2) LINE OUT (SPKR, ETC.) LINE IN(MIC, FUTURE USE) HUB-101 FAX-30 FA-50 FISH FINDER (DFF series, ETR-6/10N, ETR-30N, FCV-1150) : Standard Supply : Optional Supply : Local Supply DR2D/4D/ 4A/6A MFD12 RU-3423 DRS12A PSU-012 MFD12 PR-62 RU-3423 DRS25A PSU-013 MFD12 PR-62 RU-1746B-2 iii
6 EQUIPMENT LISTS Standard supply Name Type Code No. Qty Remarks Multi Function Display Optional supply MFD8-1 Choose one. MFD12 - Instalaltion materials CP set For MFD8, CP *, cables CP For MFD12, CP *, cables Spare Parts SP set For MFD8, fuses SP For MFD12, fuses Accessories FP set Panel remover *See the lists at the back of this manual. Name Types Code No. Remarks Cable Assy MJ-A7SPF C m, NMEA0183, w/connector M12-05BM+05BF , 1 m, NMEA2000, w/micro connectors M12-05BM+05BF , 2 m, NMEA2000, w/micro connectors M12-05BM+05BF , 6 m, NMEA2000, w/micro connectors M12-05BFFM , 1 m, NMEA2000, w/micro connector M12-05BFFM , 2 m, NMEA2000, w/micro connector M12-05BFFM , 6 m, NMEA2000, w/micro connector CB-05PM+05BF , 1 m, NMEA2000, w/ micro connectors CB-05PM+05BF , 2 m, NMEA2000, w/ micro connectors CB-05PM+05BF , 6 m, NMEA2000, w/ micro connectors CB-05BFFM , 1 m, NMEA2000, w/ micro connector CB-05BFFM , 2 m, NMEA2000, w/ micro connector CB-05BFFM , 6 m, NMEA2000, w/ micro connector iv
7 Name Types Code No. Remarks Cable Assy MOD-Z LAN cross, 4-pair, 2 m NMEA Connector MOD-Z LAN cross, 4-pair, 5 m MOD-Z LAN cross, 4-pair, 10 m MOD-Z LAN straight, 2-pair, 3 m MJ-A6SPF C For FAX-30, ETR6N/10N connection LTWSS050505FMF- TS001 LTWMC-05BMMT- SL8001 LTWMC-05BFFT- SL8001 LTWNC050505FMF- TS001 LTWMN-05AMMT- SL8001 LTWMN-05AFFT- SL NMEA 2000 distributor, micro style NMEA 2000 terminator, male, micro style NMEA 2000 terminator, female, micro style NMEA 2000 distributor, mini style NMEA 2000 terminator, mini style NMEA 2000 terminator, female, mini style In-line Terminator FRU-0505-FF-IS NMEA 2000 connector w/terminator, micro style DVI-D Cable DVI-D/D SINGLELINK m, for Multi-purpose LCD connection DVI-D/D S-LINK m, for Multi-purpose LCD connection External Buzzer OP Junction Box FI For FI-50 series connection Rectifier RU w/o PSU-012 PR VAC, w/psu VAC, w/psu VAC, w/psu VAC, w/psu-012 RU-1746B VAC -For PSU-012 and MFD -PSU-013 Network Hub HUB Joint Box TL-CAT For LAN cable extension Connector Boot OP Operator s Manual OME NMEA 2000 Interface Unit IF-NMEA2K1 - v
8 1. MOUNTING 1.1 Mounting Considerations MFD8 MFD12 When selecting a mounting location for the MFD8/12, keep the following in mind: The temperature and humidity at the mounting location should be moderate and stable. Locate the unit away from exhaust pipes and ventilators. The mounting location should be well ventilated. Mount the unit where shock and vibration are minimal. Keep the unit away from electromagnetic field generating equipment such as motors and generators. For maintenance and checking purposes, leave sufficient space at the sides and rear of the unit and leave slack in cables. Minimum recommended space is shown the outline drawing for the display units. Do not mount the MFD8/12 on the overhead. A magnetic compass will be affected if the display unit is placed too close to it. Observe the compass safe distances shown in the SAFETY INSTRUCTIONS to prevent disturbance to the magnetic compass. The MFD8/12 can be flush mounted in a console or panel, or mounted on a desktop. 1
9 1.2 Flush mounting 1. Prepare a cutout in the mounting location using the template sheet (supplied) for the MFD8 or Remove the front panel from the MFD by unfastening the catches at the rear of the panel, in the order as shown in the figure below. Note: Catches are tight to unfasten. Take care not to break the panel. 3. Attach the mounting sponge to the display unit. 4. Fix the display unit by using four self-tapping screws (supplied). 5. Attach the front panel to the display unit Cutout MFD, rear view (catches locations and order to unfasten) Mounting sponge Display unit (ex. MFD12) Self-tapping screws (4 pcs.) Front panel How to detach the front cover from the mounting place. To detach the front panel after mounting the unit, use the remover (supplied) as below. Note that the front cover may be damaged if the following is not done. 1. Set the remover to a notch on the lower side of the unit. 2
10 2. Pull the remover to raise the panel slightly. Do this for all notches on the lower side of the unit. 3. Insert the remover to the space at the both sides of the unit, and pull the remover to raise the panel slightly. 4. Use your hands to detach the front panel at lower side of it. 3
11 1.3 Desktop Mounting Follow the procedure below to mount the MFD8 or 12 on a desktop. 1. For MFD12, attach a liner to each side of the display unit. 2. Fix the hanger by using self-tapping screws (supplied). 3. Screw knob bolts into the display unit, set it to the hanger, and tighten the knob bolts. MFD8/12 Liner (MFD12 only) Hanger Knob. 4
12 2. WIRING All wirings are terminated at the rear of the equipment. DO NOT turn on the power until completing all the wiring. For detailed information about NMEA 2000 wiring, see Furuno CAN bus Network Design Guide (TIE-00170) on Tech-Net VDC MJ-A3SPF ZC (MFD8) MJ-A3SPF ZC (MFD12) To ship's ground Radar Sensor or PSU-012/013 Ground wire IV-8sq. NMEA 0183 (ex. GP-320B) Radar Sensor (two-way cable supplied with DRS), HUB-101 (MOD-WPAS ), etc. NMEA 2000 port FRUDD-18AFFM-L180 External display (MU-150C etc.) DVI-D/D cable 5 m/10 m NMEA 0183 equipments (GPS plotter. Echo sounder, External buzzer, etc.) *Remove the cover to access these connectors. (See the next page.) DVI-D* USB port* (Ver. 1.1, mouse, keyboard, etc.) Video interface devices* AUDIO* (L: Line out, R: Line in (future use)) : Standard supply : Option : Local supply 5
13 Using DATA2 port (NMEA0183) To connect multiple NMEA0183 equipments, use the cable assy FRUDD-18AFFM-L180 supplied. This cable has an 18P connector. Solder the applicable wires of the FRUDD-18AFFM-L180 and the wires from sensors. The wire arrangement is shown below. Pin No. Color Function Remark (port No.) 18 Light green NET-C IN (0V) NMEA 2000 Power 17 Pink NET-S IN (+15V IN) 16 Purple Shield 15 White BUZZER or EVENT IN External buzzer or event switch 14 Gray SPEED-ALARM C Speed alarm contact 13 Yellow SPEED-ALARM H 12 Black/White +12V External buzzer power 11 Black GND 10 Blue/White RD3-C Port 3 9 Blue RD3-H 8 Green/White TD3-B 7 Green TD3-A 6 Orange/White GND 5 Orange GND 4 Brown/White RD2-C Port 2 3 Brown RD2-H 2 Red/White TD2-B 1 Red TD2-A 6
14 Video interface devices (analog type) Maximum two camera/video devices can be connected. For this connection, the following cable is necessary (local supply). BNC connector 3C2V (Japan Industrial Standard (JIS), or the equivalent) coaxial cable (impedance 75Ω) Insulator Shield Video interface devices (digital type) Conductor S = 0.19 mm = 0.5 mm Vinyl sheath The NavNet 3D can display digital pictures from IP cameras (AXIS model 212 or 207 only) via LAN. IP addresses are allocated through 006. For details, see the Operator s Manual for model 212 and
15 How to connect cables to DVI-D, VIDEO, AUDIO or USB ports The above-mentioned ports are behind the connector cover on the rear panel. Access to the ports and connect cables as shown in the procedure below. There are two methods, i.e., for waterproofing or non-waterproofing. For waterproofing This method requires the optional connector boot (Type: OP19-7, Code No.: ). Contents of OP19-7 Name Type Code No. Qty Boot cover Fixing metal Rubber stopper Cable tie CV-150B Binding screw M3x Unfasten four binding screws to remove the connector cover at the rear of the display unit. Discard binding screws. Binding screw (4 pcs.) Connector cover 2. Pass DVI-D, VIDEO, AUDIO and/or USB cables through the fixing metal (supplied). Fixing metal 8
16 3. Attach each connector to the appropriate location at rear of the display unit. 4. Pass cables through the slit on the boot cover. 5. Set a rubber stopper to each cable. The largest hole is for the DVI-D cable. Rubber stopper Cables 6. Use four binding screws (M3x10, supplied) to fasten the fixing metal and boot cover to the display unit. Connectors Fixing metal Binding screws Rubber stopper Boot cover 7. Slide the rubber stopper into the hole of the rubber boot, and fasten the cable tie to hold the rubber boot and stopper. Rubber boot Cables Push Wind the cable tie around here. Rubber stopper 9
17 For non-waterproofing When you do not need the waterproofing, use the cable fixing metal (supplied as the installation materials). 1. Unfasten four binding screws to detach the connector cover at the rear of the display unit. Discard binding screws. Binding screw (4 pcs.) Connector cover 2. Attach the cable fixing plate by using the binding screw (M3x10, supplied as the installation materials). Binding screw (M3x10) Cable fixing plate 3. Attach each connector to the appropriate location at rear of the display unit. 4. Wind the cable tie (supplied as the installation materials) to fix the cables to the cable fixing plate. 10
18 3. SETTING UP THE EQUIPMENT This chapter shows you how to set up your system according to the equipment you have connected. To do this more easily the Installation Wizard is provided. It has all the items necessary for setting up your system. The Installation Wizard has four tabs, and each tab has some dialog boxes. You can construct your network system by setting these items in Wizard series. Note: Do not transmit the radar until youhave set up the radar sensor (on page 23). Own tab Set the NMEA 0183/2000 and Analog video devices connected to your MFD. Global tab Set data on the network. These data can be shared with MFDs on the network. Sounder tab This tab appears when a network sounder (DFF, ETR series) or FCV-1150 is connected. Set the items for frequencies and TD-ID transducer of Airmar as appropriate. Radar tab This tab appears when a radar sensor (DRS series) or FAR-2xx7 series (Program Version No.: or before, Type-C only) is connected. Set the antenna position and adjust the heading and main bang. Used key on the Installation Wizard 4 Left-click button 3 Cursor pad 2 RotoKey 1 POWER key A commercial USB mouse or keyboard can be used. 11
19 3.1 Setup for Single MFD in the Network When you have an MFD in the network, do the following procedures. Language, DHCP server setting 1. Press the POWER key on the control unit to power the system. In a few minutes, the Installation Wizard starts. After the system has confirmed sensors, the language selection screen appears. The default language is English. If you don t need to change the language, click the [Next] button. If necessary, change language: choose the Select Language pull-down menu, and push the left-click button. Note that the language of the Installation Wizard is English regardless of language setting. And press the [Next] key. English US Save and Exit The system counts the number of sounders, radars and other sensors you have connected and displays the results. Allow the system to count the number of sensors, which takes about 30 seconds. 29 The following menu appears. 2. Confirm that the Master (DHCP Server) pull-down menu shows ON, and press [Save and Exit] button to turn the power off. 3. Press the POWER key to turn on the equipment again. After the confirming sensors. the Master (DHCP Server) setting screen appears again. 4. Press the [Next] button to show the Own-NMEA2000 tab. 12
20 Own-NMEA 2000 tab Check the PGNs (Parameter Group Number, NMEA 2000 messages) to output from the NMEA 2000 port, and click the [Next] button. PGN No. and Messages PGN No. Message mean System Time Rudder Vessel Heading Rate of Turn Attitude Magnetic Variation Speed, Water referenced Water Depth Position, Rapid Update COG & SOG, Rapid Update GNSS Position Date Time & Date XTE Navigation Data Wind Data Environmental Parameters GNSS Sats in view Navigation-Route/WP information Direction Data 13
21 Own-NMEA 0183 port 1 through 3 tabs Set up the NMEA0183 data ports. NMEA0183 port 1: DATA1 connector (7 pins) NMEA0183 port 2: DATA2 connector (pin #: 1 to #4) NMEA0183 port 3: DATA2 connector (pin #: 7 to 11) All NMEA0183 ports on your MFD are assigned respective nicknames. If you don t like the preassigned nickname, you can change it at Nickname field. Use the cursor pad to select location. Rotate the RotoKey to select character and push it to confirm selection. Repeat this operation to complete the nicknames 5. Set baud rate at the Baudrate pull-down menu, 4800 or Choose how to indicate waypoints, Name or ID No., at the WPT ID Format pull-down menu. 7. At the L/L format dialog box, choose how many digits (seconds) to display after decimal point in latitude and longitude. 8. Choose the NMEA 0183 version to output, Ver 1.5, Ver 2.0 or Ver 3.0, at the Output format pull-down menu. 14
22 9. At the Output Sentences field, check the NMEA0183 sentences to output. NMEA0183 Output sentences Name Meaning Name Meaning AAM Waypoint arrival alarm RMA Loran-C data APB Autopilot sentence RMB BOD Bearing origin to destination RMC GPS/Transit BWC/BWR Bearing and distance to waypoint VHW Speed/heading (through water) DBT Depth below transducer VTG Speed over ground, course (true) GGA GPS fix data WPL Waypoint location GLL Geographic position (L/L) XTE Cross-track error, measured GTD Geographical Position, Loran-C TDs ZDA Time and date HDT Heading true ZTG UTC and time to destination waypoint MTW Water temperature att Heading/Roll/Pitch 10.At the Sensor Type field, check sensor data that is input to the MFD. Example 1: Check Position & SOG/COG for GPS receiver connection. Example 2: Check Heading for heading sensor connection. When using the DATA2 and/or DATA3 ports on the MFD, set the NMEA0183 port 2 and/or port If the GPS receiver GP-320B is connected, click the [Advanced Setup] button to show the setting menu for GP-320B. Set all items referring to the table shown below. Basic Setup 15
23 Menu item POS. Smoothing SOG/COG Smoothing Disable Satellite INIT. Position ANT. Position Description When the receiving condition is unfavorable, the GPS fix may change, even if the vessel is dead in water. This change can be reduced by smoothing the raw GPS fixes. A setting between 000 to 999 is available. The higher setting the more smoothed the raw data, however too high a setting slows response time to change in latitude and longitude. This is especially noticeable at high ship s speeds. Increase the setting if the GPS fix changes. During position fixing, ship s velocity (speed and course) is directly measured by receiving GPS satellite signals. The raw velocity data may change randomly depending on receiving conditions and other factors. You can reduce this random variation by increasing the smoothing. Like with latitude and longitude smoothing, the higher the speed and course smoothing the more smoothed the raw data. If the setting is too high, however, the response to speed and course change slows. For no smoothing, enter all zeroes. Every GPS satellite is broadcasting abnormal satellite number(s) in its Almanac, which contains general orbital data about all GPS satellites, including those which are malfunctioning. Using this information, the GPS receiver automatically eliminates any malfunctioning satellite from the GPS satellite schedule. However, the Almanac sometimes may not contain this information. If you hear about a malfunctioning satellite from another source, you can disable it manually. Enter satellite number (max. 3 satellites) in two digits. Set initial latitude/longitude position for cold start. Enter the GPS antenna positioning bow-stern and port-starboard position. Origin ANT. Height Rx Mode Enter the height of the GPS antenna unit above sea surface. Choose position fixing method: 2D (three satellites in view), 2D/3D (three or four satellites in view whichever is greater). WAAS Mode Select ON to use the WAAS mode. WAAS Search WAAS Alarm WAAS satellite can be searched automatically or manually. For manual search, enter appropriate WAAS satellite number. When the WAAS signal is lost, the audible alarm sounds one of two ways. On: Alarm sounds continuously until the WAAS positioning mode is available again or the alarm is acknowledged (by key operation). Off: Alarm sounds three times. 12.Click the Next button. 16
24 Global-Analog Video tab 13.All analog video equipment connected to the MFD are assigned respective nicknames ( PinP1 to 2 ). If you don t like the preassigned nickname, you can change it here. Use the cursor pad to select location. Rotate the RotoKey to select character and push it to confirm selection. Repeat this operation to complete the nicknames. 14.Press the [Next] button. Global-Boat tab Enter your boat s dimensions, length/width unit and engine s specifications. 15.Choose the desired unit of length and width for the boat (ft, m) at the Length/Width/Height unit pull-down menu. 16.Set the length of boat at the Boat length pull-down menu. 17.Set the width of boat at the Boat Width pull-down menu. 18.Choose the number of engines on your boat (1, 2 or 3) at the Number of Engine pull-down menu. 19.Choose the max. scale of the tachometer (3000 rpm, 4000 rpm or 8000 rpm) at the Engine Revolution pull-down menu. 20.Choose the max. scale of the oil pressure meter (200kPa/2Bar/29Psi, 500kPa/5bar/72.5Psi or 1000kPa/10bar/145Psi) at the Max. Oil Pressure pull-down menu. 21.Choose the max. scale of the boost meter (200kPa/2Bar/29Psi, 500kPa/5bar/72.5Psi or 1000kPa/10bar/145Psi) at the Max. Boost Pressure pull-down menu. 22.Click the [Next] button. 17
25 Global-Nickname tab All equipment in the NavNet 3D system are assigned respective nicknames. If you don t like the preassigned nickname, you can change it here. Use the cursor pad to select location. Rotate the RotoKey to select character and push it to confirm selection. Repeat this operation to complete the nicknames. 23.Click the [Next] button. Global-IP Camera tab The IP cameras connected to the network are assigned a name ( IPcamera1 to 4 ). If you don t like the preassigned name, you can change it here. Change the name using the cursor pad and RotoKey as is the Global-Nickname tab. 24.Click the [Next] button. 18
26 Global-Data Source tab The Data Source dialog box shows the sources of various nav data. In case of multiple sensors for a nav data item, for example, several position-fixing equipment, choose the sensor to use, with the pull-down menu. Item Description Setting Position & SOG/ COG Choose the position-fixing sensor to use. GP-320B, GP-310B, NMEA 2000 format GPS Heading Choose the heading sensor to use. SC-30, PG-500, PG-1000, Other Speed Through Water Choose the speed (STW) sensor to use. Smart sensor (NMEA 0183), Speed sensor (DFF), Smart sensor (NMEA 2000), Other (NMEA 0183) Water Depth Choose the depth sensor to use. Smart sensor (NMEA 0183), Speed sensor (DFF), Smart sensor (NMEA 2000), Other (NMEA 0183) Water Temperature Choose the temperature sensor to use. Smart sensor (NMEA 0183), Speed sensor (DFF), Smart sensor (NMEA 2000), Other (NMEA0183) Wind Choose the wind sensor to use. FI-303, FI-501/502, WS-200, Other Date & Time Choose the date and time source to use. GP-320B, GP-310B, SC-30, NMEA 2000 format GPS, Other Roll and Pitch Choose the motion sensor to use. SC-30, WS-200, Other AIS Choose the AIS equipment to use. FA-150, FA-30, Other 25.Click the [Next] button. When the GP-330B or WS-200 is connected to the NMEA2000 network, go to the GPS Mode. Set the WAAS, referring to the step 29. If not, go to step
27 26.The GPS Mode tub appears when the GP-330B or WS-200 is connected. Set the WAAS Mode and WAAS Search, and click the [Next] button. (See the list on page 21.) Sounder, Radar tabs When your MFD is connected to a sensor(s), i.e., network sounder (DFF, ETR or FCV-1150) and/ or radar sensor (DRS or FAR-2xx7), a dialog box appears with the name of the sensor shown in a tab. Sounder 27. Click the Sounder Source select dialog box, and choose the network sounder, among DFF1, DFF3 and ETR. (Setting for DFF1,3) a) Click the Transducer Setup pull-down menu, and choose Model Number, TD-ID or Manual, according to the transducer connected. Model Number: Furuno s transducer TD-ID: Airmar s transducer w/td-id Manual: Transducers other than above b) If you choose Model Number at step a), click the High Frequency and Low Frequency pulldown menus, and choose the applicable model type. For TD-ID and Manual, set the high and low frequencies. c) For DFF1, click the Power pull-down menu, and choose 1k(W) or 600W appropriately. 20
28 d) If the satellite compass SC-30 or SC-50/110 is connected, set the distance between antenna unit (or sensor) of the satellite compass and transducer (high and low if connected) at the Transducer Position for SC pull-down menus. Bow-stern: Set the distance from antenna unit to the transducer in bow-stern direction. When the transducer is located on the fore side, set a positive value. Up-down: Set the distance from the transducer to the antenna unit in the vertical direction. Port-starboard: Set the distance from antenna unit to the transducer in port-starboard direction. When the transducer is located on the starboard side, set a positive value. SC m (Bow-stern) 9.3 m (Up-down) High SC-30 Low 1.0 m 0.8 m 1.4 m (Bow-stern) (Port-starboard) e) Click the Motion Sensor pull-down menu, and choose SC-30 or SC-50/110 if connected. f) Set the transducer position at the Transducer Position pull-down menus. Origin g) If the DFF3 is equipped with a water temperature sensor, click the Temperature Port pulldown menu, and choose the temperature source, MJ (NMEA0183 connector), Highfreq(ency) or Low-freq(ency). h) If a radar sensor is connected, click the Next button to continue. Note: For DFF3, set the tap setting in the network sounder after setting up all the MFDs. For details, see the Operator s Manual for DFF3. 21
29 (Setting for ETR) a) Click the Transducer Setup pull-down menu, and choose Model Number or Manual, according to the transducer connected. Model Number: Furuno s transducer Manual: Transducers other than Furuno b) If you choose Model Number at step a), click the High Frequency and Low Frequency pulldown menus, and choose the applicable model type. For Manual, set the high and low frequencies with the respective pull-down menus. c) Use the arrow buttons at Transducer Position to set transducer position. Origin d) If a radar sensor is connected, click the Next button to continue. (For FCV-1150) Do the step c) shown above. 22
30 Radar Set the Radar dialog box according to the radar connected. 28.Click the Radar Source select pull-down menu, and choose the radar type connected, DRS RADOME, DRS OPEN or FAR-2xx7. For FAR-2xx7, steps 30 through 31 shown below cannot be done. Set these items on the FAR-2xx7 radar. 29.Click the Antenna Height pull-down menu, and choose the height of the antenna above the waterline, among Under 10ft, 10ft-30ft or Over 30ft. 30.Do the heading adjustment as follows. You have mounted the radar sensor facing straight ahead in the direction of the bow. Therefore, a small but conspicuous target dead ahead visually should appear on the heading line (zero degrees). In practice, you will probably observe some small errors on the display because of the difficulty in achieving accurate initial positioning of the radar sensor. The following adjustment will compensate for this error. a) Set ship s heading toward a suitable target (for example, ship or buoy). b) Click the Range pull-down menu, and choose a range between and 0.25 nautical miles. c) Click the [Push TX] button to transmit. The radar picture appears on the right-half of the Radar dialog box. d) If necessary, adjust the gain, sea clutter and rain clutter using slider bars. Place the cursor on the slider bar, and press the cursor pad while pressing the left-click button. e) Click the [-] [+] buttons for Heading Adjust to bisect the target with the heading line. f) As a final test, move the boat towards a small buoy and confirm that the buoy shows up dead ahead on the radar when it is visually dead ahead. 23
31 31.If main bang appears at the screen center, click the [-] [+] buttons for MBS Adjustment so that the main bang disappears while watching the radar echo at the right-hand side of the display. 32.Click the [Radar Operation] button to adjust the tuning and video automatically. 33.Click the [Save and Exit] button to finish the Installation Wizard. Setting the zero line area (For DFF series only) Turn the zero line (transmission line) on or off. When turned off, the line is not shown, which allows you to better watch fish echoes near the surface. The width of the line changes with transducer used and installation characteristics. If the width of the line is 1.0 m or more, set the line area as below. 1. At the normal operation mode, press the MENU key while pressing the CNTRL key down to open the Serviceman menu. 2. Rotate the Rotokey to choose the Fish Finder tab, and push the Rotokey. 3. Rotate the Rotokey to choose Zero Line Rejection, and push the Rotokey to turn the zero line on. The icon turns green color, and the cursor moves to Zero Line Range. 4. For DFF3, rotate the Rotokey to set the effective area (setting area: 1.0 to 2.0 m) and push the Rotokey. 5. Press the MENU key to close the menu. 24
32 3.2 Setup for Multiple MFDs in the Network When you have multiple MFDs in the network, designate one as the DHCP (dynamic Host Configuration Protocol) server. 1. Confirm that applicable DIP switches connected MFDs on the internal hub to ON. 2. Turn on the MFD chosen to act as DHCP server. 3. Select Language and click the [Next] button. The system counts the number of sounders, radars and other sensors you have connected and displays the results. Allow the system to count the number of sensors, which takes about 30 seconds. 4. Set Master (DHCP Server) setting to ON. 5. Click the [Save and Exit] button. (The unit turns off automatically after one minute.) 6. Turn on the server MFD. 7. Turn on all other MFDs in the network. 8. Carry out the Installation Wizard settings on the master MFD, referring to section Set up the next MFD as follows: a) Press the POWER key to turn the power on. b) Choose language and click the [Next] button. c) Choose OFF from the Master (DHCP Server) setting box. d) Set up the MFD using the Installation Wizard, and wait for the other MFD s setting are finished. 10.Set up other MFDs. 11.After setting up all MFDs, click the [Save and Exit] button on the master MFD and the unit goes off automatically. 12.Click the [Save and Exit] button on other MFDs in the order in which they were set up. The master MFD starts the normal application, and client MFDs go to the sleep mode, which is shows the no display though the power is turned on. The power LED lights orange. 13.Press the POWER key on the master MFD for three seconds to turn off the master MFD. Confirm that other MFDs also are turned off. 14.Press the POWER key on master MFD. Confirm that the master MFD starts the normal application, and slave MFDs go to the sleep mode. To escape from the sleep mode to the normal mode, press the POWER key. 25
33 A-1
34 A-2
35 A-4 A-3
36 A-5 A-6
37 A-7
38
39
40
41
42 S-1 9/Aug/2011 Y.NISHIYAMA
43
44 The paper used in this manual is elemental chlorine free. FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, , JAPAN All rights reserved. Printed in Japan Pub. No. IME B2 (REFU ) MFD8/12 A : APR B2 : NOV. 10, 2011 * * * * * *
Installation Guide v3.2 MFD8/12/BB software v2.07 and later
Installation Guide v3.2 MFD8/12/BB software v2.07 and later READ ME FIRST! Please read this document before installing and powering ON your NavNet Display INSTALLATION TOOLS YOU WILL NEED: An ordinary
Installation Manual COLOR GPS PLOTTER GP-7000
Installation Manual COLOR GPS PLOTTER GP-7000 SAFETY INSTRUCTIONS...i SYSTEM CONFIGURATION... ii EQUIPMENT LISTS...iii. INSTALLATION.... Display Unit....2 Antenna Unit...4 2. WIRING... 5 3. ADJUSTMENTS...
Connecting instruments serially to your computer
Connecting instruments serially to your computer This TechNote will review how to connect instruments (GPS, Sounder, Heading Sensor ) to a computer. Important points such as electrical specification (RS-232
VHF 100/200 Series Radio Installation Instructions
VHF 100/200 Series Radio Installation Instructions These installation instructions are for the following VHF radios and handsets: North American Models VHF 100 VHF 200 GHS 10 International Models VHF 100i
INTEGRATED HEADING SENSOR PG-500 FLUXGATE HEADING SENSOR C-500
INTEGRATED HEADING SENSOR PG-500 FLUXGATE HEADING SENSOR C-500 TABLE OF CONTENTS SAFETY INSTRUCTIONS... i FOREWORD... ii SYSTEM CONFIGURATION... iii EQUIPMENT LIST... iv 1. OPERATION... 1 1.1 Controls
NavNet 3D FAQ v2.0. Furuno USA, Inc. Table of Contents
NavNet 3D FAQ v2.0 Furuno USA, Inc Table of Contents 1. NavNet 3D System... 1 Q1.SYS How many NavNet 3D MFDs are allowed in one network?... 1 Q2.SYS Can I connect multiple position, depth and other data
KVT-729DVD INSTALLATION MANUAL
MONITOR WITH DVD RECEIVER KVT-729DVD INSTALLATION MANUAL B54-4516-00/00 (EV) Accessories 1 0...1...1 2!...1...2 3...1 4 5...1...1 6...2 7...4 8...4 9...2 2 KVT-729DVD Installation Procedure 1. To prevent
INSTALLATION MANUAL NMEA DATA CONVERTER
INSTALLATION MANUAL NMEA DATA CONVERTER Model IF-NMEA2K2 WARNING Do not install the unit where it may get wet from rain or water splash. Water in the unit can result in fire, electrical shock or damage
GO7. Getting Started ENGLISH. simrad-yachting.com
GO7 Getting Started ENGLISH simrad-yachting.com GO7 Getting Started 3 4 GO7 Getting Started Contents 7 Introduction 7 The Home page 8 Application pages 9 Integration of 3 rd party devices 9 GoFree wireless
Configuring the FAR2XX7 Series Radar for use with MaxSea Time Zero
Configuring the FAR2XX7 Series Radar for use with MaxSea Time Zero Introduction In order to operate with MaxSea Time Zero AND NavNet3D, the FAR2XX7 s processor software must be version 02.5x. If you plan
GoFree Tier 1 Data Networking Specification Revision 0.6
GoFree Tier 1 Data Networking Specification Revision 0.6 Introduction The Simrad GoFree Tier 1 data networking standard is an open protocol designed to allow mobile devices (tablets, smartphones and other
The future today with FURUNO's electronics technology. FURUNO ELECTRIC CO., LTD.
R R The future today with FURUNO's electronics technology. FURUNO ELECTRIC CO., LTD. 9-52 Ashihara-cho, Nishinomiya City, Japan Telephone: +81 (0)798 65-2111 Telefax: +81 (0)798 65-4200, 66-4622 URL: www.furuno.co.jp
USER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
HDS Gen2 RTM 4.0 software update
HDS Gen2 RTM 4.0 software update The HDS RTM 4.0 software update enables autopilot control of outboard motors and includes features for Jeppesen 4D charts. Outboard motor autopilot To use outboard autopilot
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
ikommunicate NMEA - SignalK Gateway
ikommunicate NMEA - SignalK Gateway 1. Introduction Congratulations on the purchase of your ikommunicate Gateway. It is recommended that your gateway is installed by a professional installer. If ikommunicate
Alarm Security Kit - NVR
Alarm Security Kit - NVR EN The alarm configuration menu (see above right screenshot) allows you to configure and change settings for the PIR movement sensors, window/door sensors, remote controls (key
Installing the IF-NMEASC & SC30 Windows XP Drivers & Software
Installing the IF-NMEASC & SC30 Windows XP Drivers & Software The following document will outline the installation and use of the IF-NMEASC and SC-30 USB drivers and SC-30Tool software in three parts:
* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2
COMMERCIAL INSTALL GUIDE 2 Contents How to Use This Guide: The first section of this guide is designed to assist you with the installation of your DECK Monitoring hardware. The revenue grade meter and
GV- RK1352 Card Reader
GV- RK1352 Card Reader The GV-RK1352 is a card reader with keypad, designed to recognize PIN codes, identification cards or both. Featured with the Wiegand and RS-485 outputs, the unit can be connected
SATLAB Field Tools. User Guide for SL55
SATLAB Field Tools User Guide for SL55 Date Update No 2013 / April 1 Page1 Contents 1. Bluetooth Connection 3-9 2. Static Data Collection 10-11 3. Register Code Access 12-13 4. NMEA Data Management 14-16
=============================== WARNING
=============================== WARNING EXPLANATION OF GRAPHICAL SYMBOLS This symbol is intended to alert the user to the presence of unprotected dangerous voltage" within the product's enclosure that
Installation Manual BRIDGE ALARM SYSTEM BR-1000
Installation Manual BRIDGE SYSTEM BR-000 SAFETY INSTRUCTIONS...i SYSTEM CONFIGURATION...ii EQUIPMENT LISTS...iii. HOW TO INSTALL THE EQUIPMENT...-. Bridge Panel...-. Processor Unit...-. Cabin Panel, Timer
StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com
StructureScan HD Module Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Disclaimer As Navico is continuously improving this product, we retain the right to make changes
MANUAL PC1000R [email protected]
MANUAL PC1000R [email protected] Features The APart PC1000R is a professional multisource CD/USB/SD card music player, equipped with balanced and unbalanced analog outputs, coaxial and optical digital
Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL
Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL e-4 SAFETY PRECAUTIONS Federal
GPS Selection Guide. EZ Guide 500 & 250 Trimble #
GPS Selection Guide Trimble FMX 1000 & Case IH FM 1000 Precision Parts Ref Doc Trimble CFX 750 & Case IH FM 750 750 1000 with Hydraulic Steer - Trimble Aftermarket 725599 955443 955439 with Hydraulic Steer
Connecting to the Internet
Connecting to the Internet Connecting the Gateway to the Internet Configuration of TCP/IP Protocol Installing the USB Drivers Connecting Ethernet Network Devices Connecting USB Network Devices Connecting
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS This equipment has been tested and found to comply with the limits for a CLASS A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
ShareLink 200 Setup Guide
ShareLink 00 Setup Guide This guide provides instructions for installing and connecting the Extron ShareLink 00. The ShareLink USB 00 Wireless Collaboration Gateway allows anyone to present content from
Installation manual. Simrad AP24/28 EVC, Volvo IPS Pilot System with SG05 SimNet-Volvo Gateway. English
Installation manual Simrad AP24/28 EVC, Volvo IPS Pilot System with SG05 SimNet-Volvo Gateway English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Installation manual Simrad
EV-1000 Series DVR. Quick Operation Guide. Version 1.0.0
EV-1000 Series DVR Quick Operation Guide Version 1.0.0 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to
Manual. Simrad StructureScan LSS-1 Sonar Module. English
Manual Simrad StructureScan LSS-1 Sonar Module English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Disclaimer As Navico is continuously improving this product, we retain the
Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA
Quick Start Guide Cisco SPA232D Mobility Enhanced ATA Package Contents Analog Telephone Adapter Ethernet Cable Phone Cable Power Adapter Quick Start Guide Product CD-ROM Welcome Thank you for choosing
Operation Manual For NDJ-8S Digital Rotary Viscometer
Operation Manual For NDJ-8S Digital Rotary Viscometer 1 Contents 1. General... 2 2. Main technical data... 2 3. Working principle... 2 4. Installation... 3 5. Operation procedures... 4 6. Precautions...
V.I.P. Kit. Video Insight Pilot Kit. (Video Insight Pilot Kit).
V.I.P. Kit (Video Insight Pilot Kit). Video Insight Pilot Kit Please follow these instructions and everything should go very smoothly. Before you begin, you will need to establish (or obtain from your
HDCVI Series DVR Quick Start Guide
HDCVI Series DVR Quick Start Guide Version 1.1.0 Welcome Thank you for purchasing our HDCVI DVR! This quick start guide will help you become familiar with our HDCVI DVR in a very short time. Before installation
IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited
(Rev. 1.0) China Aerospace Telecommunications Limited Contents 1. Introduction......3 2. Specifications...4 2.1 External Interface... 4 2.2 Status Indicator...... 5 2.3 Technical Parameters... 6 3. Device
Traditional Sonar and DSI Sonar Installation
Traditional Sonar and DSI Sonar Installation This document covers the installation of the transducer and display unit installation, which includes connecting the unit to power and installing the unit on
Yamaha Engine NMEA2000 Connection
Yamaha Engine NMEA2000 Connection Many Yamaha outboard engines have the ability to output engine data to a NMEA 2000 network. This output from the engine can be displayed on a NMEA 2000 compatible Navico
Volvo Penta IPS Autopilot System DPU Installation and System Connections. Document Number: 87054-1 Date: May 2005
Volvo Penta IPS Autopilot System DPU Installation and System Connections Document Number: 87054-1 Date: May 2005 2 Volvo Penta IPS Autopilot System Handbook information To the best of our knowledge, the
Installation & User Manual Radio Remote rev1.0.3
EN Installation & User Manual Radio Remote rev1.0.3 RC-20E RC-21E RC-22E RC-23E SLEIPNER MOTOR AS P.O. Box 519 N-1612 Fredrikstad Norway Tel: +47 69 30 00 60 Fax: +47 69 30 00 70 www.side-power.com [email protected]
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
MaxSea TimeZero PLOT and ECS v2.1
MaxSea TimeZero PLOT and ECS v2.1 New Features in MaxSea TimeZero PLOT New 3D WorkSpace A new 3D WorkSpace is now available in full screen or split screen (2D/3D): This new WorkSpace is always centered
R4 AIS Transponder System
Saab TransponderTech AB R4 AIS Transponder System Troubleshooting Guide This page is intentionally left blank PI-08-195 A Page 2 Copyright The content of this document and its attachments shall remain
PU-USBX. USB over Ethernet Extender OPERATION MANUAL
PU-USBX USB over Ethernet Extender OPERATION MANUAL Safety Precautions Please read all instructions before attempting to unpack or install or operate this equipment, and before connecting the power supply.
Servicom G.R.I.P. Enabling Global Push-to-Talk over BGAN and Fleet Broadband Version 01 30.09.11
Servicom G.R.I.P. Enabling Global Push-to-Talk over BGAN and Fleet Broadband Version 01 30.09.11 Contents 1 Overview... 1 2 Background... 1 3 Key Features... 2 4 Typical Users... 2 5 Benefits to BGAN and
Addendum for Zeus Touch software updates
*988-10802-001* Addendum for Zeus Touch software updates www.bandg.com 2 ZC1 Remote Controller 2 New chart features 5 Fusion Link Support 6 NMEA 0183 Data logging 6 Damping 7 Configuring the ZG100 GPS
Table of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1
Table of Contents Chapter1. Introduction...1 1.1 Before Installation... 1 1.2 System Requirements... 1 Chapter2. IVS-110 1-Channel Internet Video Server...2 2.1 Package Content... 2 2.2 Physical Installation...
RMK-9. Installation and Operation instructions. ENGLISH Date: 04-2013 Document number: 81351-1-EN 2013 Raymarine UK Limited
RMK-9 Installation and Operation instructions ENGLISH Date: 04-203 Document number: 835--EN 203 Raymarine UK Limited ENGLISH Document number: 835- Date: 04-203 Handbook information This handbook contains
1 Technical Description Lokal-200PC
1 Technical Description Lokal-200PC 1.1 Overview laptop with in-built accummulator USB connection correlator box internal power supply laptop (if the device has been supplied by F.A.S.T.) BNC aerial connection
(0008854) A981653 REV B. 4125 system setup and deployment quick start guide
(0008854) A981653 REV B 4125 system setup and deployment quick start guide OPERATION IN AIR Do not operate the system while the tow fish in air for extended periods. The system may be enabled to transmit
Mobile Satellite Solutions. A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL STOW SEARCH
Mobile Satellite Solutions A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL SEARCH STOW Ver. 1 June 2012 WARNING Make all electrical and coax connections from the controller
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
User Manual Color video door phone
User Manual Color video door phone CDV-70KM Thank you for purchasing COMMAX products. Please carefully read this User s Guide (in particular, precautions for safety) before using a product and follow instructions
SP-110 Autopilot INSTALLATION AND SERVICE. www.si-tex.com
SP-110 Autopilot INSTALLATION AND SERVICE www.si-tex.com BLANK PAGE SI-TEX SP-110 SS30 2 10/25/2011 Index WWW.SI-TEX.COM... 1 INDEX... 3 WARNING!... 4 SP-110 AUTOPILOT SYSTEM... 5 BLOCK DIAGRAM OF FULL
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system 1018 2-way pager system
MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system 1018 2-way pager system Remote Control Motorcycle Alarm System Installation & Operation Instructions Sistema de Alarma de
OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder
P R O D U C T G R O U P OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder Manual # 600-0901 November 30, 1999 Rev. D - 99068 DESCRIPTION The ST-888 Mobilecall Display Decoder is a desktop
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
GV-VR605A DC Voltage Regulator
Video 1 GV-VS04H www.geovision.com.tw Video 2 Video 3 Video 4 Audio 1 Speaker Out /Audio 2 Reset Ready Disk Full/ Audio 3 Load Fault Default /Audio 4 DC Voltage Regulator The is a voltage regulator designed
Paragon Explorer Lite Communication Software
CU-111 APRIL 11, 2013 Paragon Explorer Lite Communication Software For Fireye Paragon Scanners using Windows XP DESCRIPTION Paragon Explorer Lite, is the basic PC based configuration tool for Paragon model
HG600/HG800. Hydro-Power Unit. Installation and Operation Guide
HG600/HG800 Hydro-Power Unit Installation and Operation Guide Copyright 04 HydroSpin, All rights reserved. The data contained in this document is proprietary to HydroSpin. It is disclosed to the receiving
COLOR VIDEO DOOR PHONE CDV-71BE/D
COLOR VIDEO DOOR PHONE CDV-71BE/D 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com Printed
Point of view HDMI Smart TV dongle Mini RF Keyboard
Point of view HDMI Smart TV dongle Mini RF Keyboard English Contents Contents... 1 General notices for use... 2 Disclaimer... 2 Box Contents... 2 1. HDMI TV dongle... 3 1.1. Product display... 3 1.2. Instructions
GPS Navigator GP-33 W3D. www.furuno.co.jp. www.busse-yachtshop.de [email protected]
GPS Navigator GP-33 W3D www.furuno.co.jp *00017317710* *00017317710* IMPORTANT NOTICE General This manual has been authored with simplified grammar, to meet the needs of international users. The operator
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network
2M IR Mini Dome Quick Installation Guide
2M IR Mini Dome 2M IR Mini Dome Quick Installation Guide Please follow the installation steps below to set up 2M IR Mini Dome IP Camera. Check the package contents against the list below. See P.1 Physical
Color GPS Chart Plotters. CP180/CP180i CP300/CP300i. Owner's Manual
Color GPS Chart Plotters CP180/CP180i CP300/CP300i Owner's Manual WARNING!!! Electronic charts displayed by the GPS Chart Plotter are believed to be accurate and reliable, but are not intended to be a
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical
HF series Hall effect joysticks
Distinctive features and specifications 1, 2 & 3 axis configurations Dual sensors for redundancy CANbus J1939 and CANopen options Voltage regulator, 24V supply option USB 1.1 HID interface option ized
INSTRUCTION MANUAL DATA EXTRACTION PROCEDURE MODEL VR-3000/VR-3000S DO NOT OPEN. Important material for the exclusive use by Investigating Authorities
INSTRUCTION MANUAL DATA EXTRACTION PROCEDURE MODEL VR-3000/VR-3000S DO NOT OPEN Important material for the exclusive use by Investigating Authorities All brand and product names are trademarks, registered
Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)
February 2015 February 2015 Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC) This document describes how to connect an electricity meter to a SolarEdge device (inverters,
POWER TRIM 5 F AUTO TRIM AND AUTO TRIM
POWER TRIM 5 F 22217 AUTO TRIM AND AUTO TRIM Table of Contents Page Auto Trim System........................ 5F-1 Description........................... 5F-1 Auto Trim Operation...................... 5F-2
User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual
ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) User Manual Table of Contents 1 Introduction 2 General specification 3 Installation 4 Pin assignment & function of connectors 5 Drawing
USER MANUAL V5.0 VT300
GPS Vehicle Tracker USER MANUAL V5.0 VT300 Updated on 26/12/2008 Contents 1 Product Overview 3 2 For Your Safety 3 3 VT300 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2 Light and
Home Theater PC Chassis
Home Theater PC Chassis Model: HTPC 180 BA & SA Color: Black & Silver Quick Installation Guide (U.S. & Canada Only) Version 1.0 DISCLAIMER No warranty or representation, either expressed or implied, is
485USBTB-2W & 485USBTB-4W
RS-485 2-Wire RS-485 4-Wire Connector Data Rate Connector Standard Data Rate Source Input Voltage Consumption Driver CD Dimensions Enclosure Weight Operating Temp Storage Temp Op Humidity MTBF MTBF Method
Quick installation guide for the Vista Quantum QNVR Network Video Recorder
QNVR range Quick Instalation guide Quick installation guide for the Vista Quantum QNVR Network Video Recorder Full manual found on the CD supplied with the NVR Contents SCOPE OF USE... 3 1. FRONT PANEL
TP- 051 GPS RECEIVER
TP- 051 GPS RECEIVER CONTENTS 1. Overview 3 2. Features 3 3. The advantages of TP-051 GPS Receiver 4 4. The appearance and structures 4 5. Applications 5 6. Installation steps for the TP-051 GPS Receiver
VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output
VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output Introduction: VE02AL, VE05AL is designed for VGA +Stereo Audio signal over cost effective CAT5 cable to instead of VGA and
How to Install a Motherboard
How to Install a Motherboard This guide is by no means comprehensive, but serves as a general guide to installing a JNCS motherboard bundle into a standard ATX case. JNCS has already set any relevant jumpers
SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals
SSW-iLM Keypad Note: This product is designed to be installed and serviced by security and lock industry professionals Specifications Case dimensions: 6 1/2 L x 1 3/4 W x 1 1/8 D Electrical: 5-12VDC Only
INSTALLATION MANUAL COLOR GPS/PLOTTER GP-1650/1650D
INSTALLATION MANUAL COLOR GPS/PLOTTER GP-650/650D Equipment Lists... i System Configuration.... Installation of Standard Equipment... 2. Installation of Display Unit... 2.2 Installation of Antenna Unit...
Parts List. Navigation
Parts List quantity description 1 LCD-200 Display 1 LCD-200 Display cable 1 CD-ROM 2 dual lock or velcro 1 1GB SD card (optional) 1 CAN termination plug Navigation Main Menu Begin Log/Stop Log page 4 Log
5-port 10/100Base-TX Industrial Switch (314500) User s Guide
5-port 10/100Base-TX Industrial Switch (314500) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
User Manual. Video Doorphone CDV-1020AQ
User Manual Video Doorphone CDV-1020AQ 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. Tel. : +82-31-7393-540~550 Fax. : +82-31-745-2133 Web site : www.commax.com
Installation Instructions. Thermo Call TC3
Installation Instructions Thermo Call TC3 1 2 # 24990A 965 082 AMP 3 4 # 98393A # 67769A sw Improper installation or repair of Webasto heating and cooling systems can cause fire or the leakage of deadly
(2012 10 24) manual_tocomsat duo LITE.indd 20-1 2012-10-24 7:44:57
(2012 10 24) manual_tocomsat duo LITE.indd 20-1 2012-10-24 7:44:57 TABLE OF CONTENTS Table of Contents Table of Contents Safety Warning General Information Package Contents & Features Front Panel Rear
How To Use An Easymp Network Projector On A Computer Or Network Projection On A Network Or Network On A Pc Or Mac Or Ipnet On A Laptop Or Ipro Or Ipo On A Powerbook On A Microsoft Computer On A Mini
EasyMP Network Projection Operation Guide Contents 2 Before Use Functions of EasyMP Network Projection....................... 5 Sharing the Projector....................................................
3NNet KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19
3NNet USERS MANUAL KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19 RACK MOUNTABLE 4 / 8 / 16 PORT PS2 KVM SWITCH Rev 1.1 TABLE OF CONTENTS INTRODUCTION.. 3 FEATURES... 3 PACKAGE CONTENTS........
Table of Contents. General Operation 2. Air Blast Cleaning System 3. Setup 4. Changing Ticket Bags 5. Loading Printer Paper 6. Tower Light Status 7
Table of Contents General Operation Air Blast Cleaning System Setup Changing Ticket Bags Loading Printer Paper Tower Light Status Ticket Taker General - Ticket Taker Overview - Ticket Taker Operation Clearing
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable Port side cable (with black cable tie attached) Power cable Preparing for Installation 1 Overall
RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information