1 FLB Series Circuit Breakers and s Applications: FLB circuit breakers and enclosures are used: F service entrance, feeder branch circuit protection f lighting, heating, appliance and mot circuits In areas made hazardous due to the presence of flammable vaps, gases combustible dusts In damp, wet crosive locations Indos outdos at petroleum refineries, chemical and petrochemical plants and other process industry facilities where similar hazards exist To provide disconnect means, sht circuit protection and thermal time delay overload protection Features: Semi-cylindrical body shape f maximum strength at lowest practical weight Round threaded covers at each end, set at an angle to provide ready access to interi f ease of wiring Breaker is operated by an external handle which can be padlocked in either "ON" "OFF" positions. Breaker is tripfree of the handle and will open under sht circuit overload even if the handle is locked in the "ON" position Bodies have vertical through feed conduit hubs of sizes given in the listings Certifications and Compliances: NEC/CEC Class I, Division &, Groups C, D Class II, Division, Groups E, F, G Class II, Division, Groups F, G Class III NEMA/EEMAC: 3, 4, 7CD, 9EFG UL Standard: 698 CSA Standard: C. No. 30 Standard Materials: Bodies, covers and operating handles copper-free aluminum Operating shafts stainless steel Interi parts sheet steel Standard Finishes: Copper-free aluminum natural Stainless steel natural Sheet steel zinc electroplate with chromate finish Electrical Ranges: 00 and 5 ampere frame sizes Options: The following special options are available from facty by adding suffix to Cat. #: Description Suffix lugs f neutral connections (50, 00 and 5 amp.)... S46 Ground neutral stud with 3 connects (50, 00 and 5 amp.)... S68 Standard Breather (Class I, Groups C, D; Class II, Groups E, F, G; Class III)... S9 Standard Drain (Class I, Groups C, D; Class II, Groups E, F, G; Class III)... S98 Standard Breather and Drain (Class I, Groups C, D; Class II, Groups E, F, G; Class III)... S98V Universal Breather Drain (Class I, Groups C, D; Class II, Groups F, G)... S454* () Universal Breather Drains (Class I, Groups C, D; Class II, Groups F, G)... S454V* Specify Auxiliary Switch A/B (PT)... S784 A/B (PT)... S785 Dimensions In Inches : Cat. # a b c d e f g FLB40, 0, 5 /4 0 /4 6 /4 7 /4 7 7 /6 /8 FLB, 4, 47, 48, 7, 7, 73, 75,, 36, 6, 4, 49, 74, 77, 3, 36 7 / 3 3 /8 8 / 9 3 /4 9 /8 FLB4, 5, 64, 65, 67, /4 / 6 /4 9 7 /8 / *Not suitable f NEMA 4/EEMAC. With two mounting feet, one at upper right and one at lower left. Application is limited by circuit breaker design Consult Facty. Dimensions are approximate, not f construction purposes. 7 /6 3 /4 /3 7 /6 50
2 FLB Series s and s 00A Frame, Thermal Magnetic, 0 VAC/ VDC, 40 VAC/50 VDC Ordering Infmation: To der an enclosure complete with circuit breaker where there is a choice of manufacturer, insert the manufacturer's symbol in the designated position of the catalog number. s only can be dered. Select from listings. 00 ere Frame with Non-Interchangeable Trip 40VAC Max. 0VAC VDC 40VAC 50VDC 3 40VAC 3 /4 General Electric "TEB" Cat. # FLB0 TT 0 FLB0 TT0 30 FLB0 FLB0 TT30 40 FLB0 TT40 50 FLB0 TT50 FLB TT 0 FLB TT0 30 FLB FLB TT30 40 FLB TT40 50 FLB TT50 FLB3 TT 90 FLB3 FLB3 TT90 00 FLB3 TT00 FLB TT 3 0 FLB TT FLB FLB TT FLB TT FLB TT50 3 FLB3 TT 3 90 FLB3 FLB3 TT FLB3 TT
3 FLB Series s and s 00A Frame, Thermal Magnetic, VAC, 50 VDC 00 ere Frame with Non-Interchangeable Trip 480VAC Max. 480VAC 50VDC 3 480VAC "EHD" Cat. # With General Electric "TED" Cat. # FLB40 WT FLB40 TT 0 FLB40 WT0 FLB40 TT0 30 FLB40 FLB40 WT30 FLB40 TT30 40 FLB40 WT40 FLB40 TT40 50 FLB40 WT50 FLB40 TT50 FLB4 WT FLB4 TT 90 FLB4 FLB4 WT90 FLB4 TT90 00 FLB4 WT00 FLB4 TT00 FLB4 WT 3 FLB4 TT 3 0 FLB4 WT0 3 FLB4 TT FLB4 FLB4 WT30 3 FLB4 TT FLB4 WT40 3 FLB4 TT FLB4 WT50 3 FLB4 TT50 3 FLB4 WT 3 FLB4 TT 3 90 FLB4 FLB4 WT90 3 FLB4 TT FLB4 WT00 3 FLB4 TT
4 FLB Series s and s 00A Frame, Thermal Magnetic, 600 VAC, 50 VDC 00 ere Frame with Non-Interchangeable Trip Max. 50VDC 3 "FDB" Cat. # FLB WT 0 FLB WT0 30 FLB FLB WT30 40 FLB WT40 50 FLB WT50 FLB6 WT 90 FLB6 FLB6 WT90 00 FLB6 WT00 FLB WT 3 0 FLB WT FLB FLB WT FLB WT FLB WT FLB6 WT 3 90 FLB6 FLB6 WT FLB6 WT00 3 General Electric "TED" Cat. # FLB36 TT 3 0 FLB36 TT FLB36 FLB36 TT FLB36 TT FLB36 TT50 3 FLB36 TT 3 90 FLB36 FLB36 TT FLB36 TT
5 FLB Series Circuit Breakers and s 5A Frame, Thermal Magnetic, 600 VAC, 50 VDC 00 ere Frame with Non-Interchangeable Trip Max. 50VDC / 3 / "JDB" Cat. # FLB64 WT 0 FLB64 WT0 75 FLB64 FLB64 WT75 00 FLB64 WT00 5 FLB64 WT5 FLB64 WT 3 0 FLB64 WT FLB64 FLB64 WT FLB64 WT FLB64 WT5 3 3 / General Electric "TFJ" Cat. # FLB4 TT 3 0 FLB4 TT FLB4 FLB346 FLB4 TT FLB4 TT FLB4 TT ere Frame with Interchangeable Trip Max. 50VDC 3 3 *Fmerly "KB" Fmerly "JB" 3 "JD"* Cat. # FLB67 WT 0 FLB67 WT0 75 FLB67 FLB67 WT75 00 FLB67 WT00 5 FLB67 WT5 General Electric "TFK" Cat. # FLB67 WT 3 FLB5 TT 3 0 FLB67 WT0 3 FLB5 TT FLB67 FLB5 FLB67 WT75 3 FLB5 TT FLB67 WT00 3 FLB5 TT FLB67 WT5 3 FLB5 TT
8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationEDS / EFS Series Control Stations
EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent
More informationPlugs and Receptacles
Plugs and Receptacles Industrial Heavy Duty Interlocked Application and Selection Applications: Where extra protection is a requirement; interlocked units provide dead front receptacles; connection cannot
More informationGUE, GUB Junction Boxes
E GUE, GUB Junction Boxes Cl. I, Div. & 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 4*, BCD, 9EFG Ex d IIC T6, IP66 Ex d IIC, IP66, ATEX certified Explosionproof
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More informationLearning Module 13: Panelboards and Switchboards. 101 Basic Series
Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and
More informationTP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12
Bulletin DB-111B12 TP-C2 Motor Operator CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Cleaveland/Price Type TP-C2 Motor Operator
More informationSentron Series Circuit Breakers
Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of
More informationSubmit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
More informationMetallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features
Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case
More informationBERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
More informationD-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns
for harsh & hazardous (classfied) locations Construction Demolition Maintenance Turnarounds Shutdowns D-13 temporary / mobile power Temporary power products are used on industrial and construction sites
More informationTmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More informationASCO SERIES 185 Power Transfer Switches
ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from
More informationAll work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
More informationFITTINGS: CAST DEVICE BOXES. Applications. Illustrated Features
and FD Cast Hub Device Boxes UNILETS for use with Threaded Rigid Conduit and IMC. All Device Boxes have Ridge Top Construction. Furnished with Internal Ground Screw. Fittings FITTINGS: CAST DEVICE BOXES
More informationElectronic, Digital and Mechanical Vibration Switches
PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive
More informationMCC Ratings. Voltage Rating
MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control
More informationOperation and Maintenance manual. fusible shunt trip switch
Operation and Maintenance manual fusible shunt trip switch Table of Contents Fusible Shunt Trip Switch Device Overview... 2 Installation Instructions... 3 Catalog Number Selection Table... 4 Motor Fuse
More informationCAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
More informationSecondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
More informationMR221-MR222 Heavy Duty Geared Limit Switches, CE Approved
MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved MICRONOR automation components Product MICRONOR MR221 and MR222 series Heavy Duty Geared Limit Switches are for use in the most demanding industrial
More informationFLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL
FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL January, 2003 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton, FL 33431 Phone: 561-297-3129 Fax:
More informationMolded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
More informationScraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
More informationDistribution Dry Type Transformers
8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg
More informationExplosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
More informationOWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
More informationThe following components are common to most cubicles; this example is an ABB HK cubicle.
4.0 CIRCUIT BREAKER CUBICLE Learning Objectives The circuit breaker cubicle is the component of the switchgear that holds the circuit breaker, and the controls and cabling for the distribution system.
More informationELECTRIC METERING COMMERCIAL & INDUSTRIAL
ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS
More informationREAD THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!
READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the
More informationSanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
More informationDecision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features
Decision-Maker Paralleling System Power Distribution Switchboards and Circuit Breakers Power Distribution Switchboards and Circuit Breakers The generator paralleling circuit breakers for the Kohler Decision-Maker
More informationDimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)
9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity
More informationMyers Hubs. The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure
Myers Hubs The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure Myers Hubs The Original! Often imitated, never duplicated! Available in a wide range of sizes, materials
More informationCITY OF LOS ANGELES CALIFORNIA
BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI
More informationPump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationHighbay and Lowbay LED Luminaires. Energy-efficient, low-maintenance lighting for commercial and industrial applications
Highbay and Lowbay LED Luminaires Energy-efficient, low-maintenance lighting for commercial and industrial applications High Performance Highbay and Lowbay LED Luminaires AccuLite Highbay and Lowbay LED
More informationTMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations
TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations CableReady connectors are designed for use with the following cables: Type MC jacketed corrugated aluminum, interlocked
More informationINSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
More informationBussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
More informationTABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
More informationElectronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
More informationBT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
More informationPAINT BOOTH LIGHTING
PAINT BOOTH LIGHTING PAINT BOOTH LIGHTING Lighting is comprised of many components that need to be considered when selecting the appropriate fixtures and lamps to accomplish a specific task. Selecting
More informationPressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
More informationMini Power-Zone Unit Substation
Catalog 7440CT0901 2009 Class 7440 CONTENTS Description............................................. Page Product Description...........................................2 General Information...........................................3
More informationMiniature Circuit Breakers and Supplementary Protectors
Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors. Industrial Circuit Breakers QUICKLAG............................................. QUICKLAG
More informationOwner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance
Owner s Manual For Automatic Transfer Switch 100-200 Amp, Service Entrance/Non-Service Entrance Model Numbers RTST100A3 RTSP100A3 RTST150A3 RTST200A3 RTSP200A3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:
More informationWE-350 Series ¼ Turn Electric Actuator
WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information
More informationCONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13
CONTROL PANEL INSTALLATION INSTRUCTIONS Single Phase Simplex Page 2-7 3-Phase Simplex Page 8-13 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions
More informationCircuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
More informationElectrical Code Regulation
Electrical Code Regulation St. Clair County has adopted the 2005 National Electrical Code in its entirety for the unincorporated areas of the county and all communities that have contracted with the county
More informationSERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp
SERVICE ENTRANCE - UNDERGROUND 07-01-15 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS
More informationABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) 41-161J. Instruction Leaflet
ABB Instruction Leaflet 41-161J Effective: May 1997 Supersedes I.L. 41-161H Dated July 1984 ( ) Denotes Change Since Previous Issue Type COQ Negative Sequence Generator Relay (50/60 Hertz)! CAUTION Before
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable
More informationReliable on land or sea. UL 1500 Ignition proof. ABYC compliant. High interrupt capacity. Mechanical Products Company
Reliable on land or sea. UL 1500 Ignition proof. ABYC compliant. High interrupt capacity. Series 18. Count on it. Mechanical Products Company The Series 18 from. Count on it. Wherever it goes. Clearly
More informationTHERMAL INSTRUMENT CO. 217 Sterner Mill Road, Trevose, PA 19053 Telephone No. (215) 355-8400 FAX No. (215) 355-1789
THERMAL INSTRUMENT CO. 217 Sterner Mill Road, Trevose, PA 19053 Telephone No. (215) 355-8400 FAX No. (215) 355-1789 Website: www.thermalinstrument.com Email: office@thermalinstrument.com INDEX Page Instruction
More informationTorqPlus TM Electric Valve Actuators and Controls
TorqPlus TM Electric Valve Actuators and Controls Torque 150 IN/LB 600 IN/LB The Engineered Solution Bettis TorqPlus quality line of electric actuators are designed for quarter turn applications ball,
More informationMini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications
Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down
More informationMODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS
1.5, 2, 2.5, 3, 3.5, 4, 5 & 6 Ton Industrial Grade Wall Mounted Air Conditioners & Heat Pumps Unit Application Bebco Model IX-WAC/HP Industrial Grade Air Conditioners & Heat Pumps are designed as a total
More informationELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST
Name of School: OPTIONAL INFORMATION Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST Guidelines: This checklist
More informationCHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel
CHAPTER 4 UTILITY SYSTEMS ELECTRICAL Utility Systems Electrical The electrical supply to your home begins outside, where you will see either an overhead feed and piping down the side of your home or (if
More informationPump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationMTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
More informationSelection Guide. Bulletin 194R/140U External Operating Handles
Selection Guide Bulletin 194R/140U Bulletin 194R/140U Notes 2 Bulletin 194R/140U Product Overview/Product Selection Bulletin 194R/140U Next Generation Disconnect Handles Available in matte black for ON-OFF
More informationAP/UP, AP/MIL Series. Magnetic Circuit Protectors
AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction Poles Configurations Operating Characteristics Delay Curves Specifications Decision Tables 71 72 75 76 77 78 79 AP/UP, AP/MIL Series Hydraulic
More informationLighting Packages. 230 VAC Fluorescent Enclosure Light:
Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for
More informationCIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS
CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS David D. Roybal, P.E. Senior Member, IEEE Eaton Electrical 3697 Mount Diablo Boulevard Lafayette, CA 94549 Abstract Low-voltage circuit
More informationELECTRICAL INSPECTION BULLETIN (Effective 2000-03-01)
ELECTRICAL INSPECTION BULLETIN (Effective 2000-03-01) Rule 28-900 Standby Generator Installations Due to the increasing number of standby generator installations being established to maintain continuity
More information26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
More informationLIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
More informationSeries 71, 72, and 76 Modutrol IV Motors
Series 7, 7, and 76 Modutrol IV Motors PRODUCT DATA FEATURES APPLICATION The Series 7, 7 and 76 Modutrol IV Motors are spring return and nonspring return motors used to control dampers and valves. The
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationDIGITAL WARMING CABINETS
DIGITAL WARMING CABINETS INSTALLATION-OPERATION-MAINTENANCE USER MANUAL Mac Medical 820 S Mulberry St. Millstadt, IL 62260 California OSHPD Pre-approved (618) 476-3550 phone (618) 476-3337 fax December
More informationMTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
More informationArktite Heavy Duty Circuit Breaking Plugs and Receptacles
1312-1313.qxp 12/16/2013 7:04 PM Page 1312 Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Features: Arktite circuit breaking plugs and receptacles are
More informationOVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F
OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F The OVR three-phase recloser style guide aids in the proper selection of your OVR three-phase style number.
More information12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
More informationPump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.
Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration
More informationCircuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services
Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination
More informationB-Series Temperature Switches
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment
More informationLCP Coordination Panel Operations & Maintenance Manual Table of Contents
LCP Coordination Panel Operations & Maintenance Manual Table of Contents 1. Overview 2. NEC Requirements Overview 3. LCP Coordination Panel Data Sheet 4. Class CC Littelfuse CCMR Current-Limiting Fuse
More informationSolid State Timers Type F
Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application
More information2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
More informationVL circuit breakers. Information guide. www.usa.siemens.com/circuitbreakers
VL circuit breakers Information guide www.usa.siemens.com/circuitbreakers Table of contents Technical data 2 8 DG 150A frame 9 14 FG 250A frame 15 20 JG 400A frame 21 26 LG 600A frame 27 32 MG 800A frame
More informationMolded case circuit breakers
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high
More informationHPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80
Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...
More informationIn-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
More informationIRRIGATION PUMPING Table of Contents - Section 900
IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS
More informationCable/Conduit Conversion
Cable/Conduit Conversion Busway can be used in many applications where cable and conduit are more commonly used. The question arises, Why use busway instead of conventional cable and conduit? Benefits
More information2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationGenerator DoCKInG StatIonS
Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed
More informationTHE ADVANTAGES ARE YOURS
THE ADVANTAGES ARE YOURS The new switches/discrepancy switches "R0-DR0" have special characteristics that make them very different from the normal switches on the market. Listed below are some of the many
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More informationSpecification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers
Specification Guide for RVAC Direct Replacement AC Medium Voltage Circuit Breakers Table of Contents 1.0 General Work Scope...3 2.0 Standards...3 3.0 Supplier Qualifications...4 4.0 Circuit Breaker Element
More informationSquare D Safety Switches
Square D Safety Switches Power isolation solutions for daily activities and emergencies TM Make the most of your energy SM Square D Safety Switches Setting the standard for perfomance, quality, and reliability
More information