PRICE LIST May Split and Multi-Split Systems KX6 VRF Inverter Systems. HRP OEM & Export. HRP Group Technical Centre

Size: px
Start display at page:

Download "PRICE LIST May 2011. Split and Multi-Split Systems KX6 VRF Inverter Systems. HRP OEM & Export. HRP Group Technical Centre"

Transcription

1 Head Office Rougham Industrial Estate Rougham, Bury St Edmunds Suffolk IP30 9XA Tel: Fax: HRP OEM & Export Rougham Industrial Estate Rougham Bury St. Edmunds Suffolk IP30 9XA Tel: Fax: D Air Sales Ltd 159 Edinburgh Avenue Slough Trading Estate Slough SL1 4UE Tel: Fax: HRP Group Technical Centre 159 Edinburgh Avenue Slough Trading Estate Slough SL1 4UE Tel: Fax: PRICE LIST May 2011 Bedford Tel: Fareham Tel: Newcastle Tel: Southampton Tel: Birmingham Tel: Glasgow Tel: Norwich Tel: Swanley Tel: Bristol Tel: Leeds Tel: Sheffield Tel: Walthamstow Tel: Bury St. Edmunds Tel: D Air Sales (Ireland) Ltd Fitzwilliam Business Centre 77 Sir John Rogerson s Quay Dublin 2 Tel: London - Merton Tel: London - Stratford Tel: ISO9001 MHI Air Conditioning and Refrigeration Systems Headquarters is an ISO9001 approved factory for residential air conditioners and commercial use air conditioners (including heat pumps). Prices and specifications subject to change without prior notice. Slough Tel: Warrington Tel: ISO14001 MHI Air Conditioning and Refrigeration Systems Headquarters has been assessed and found to comply with the requirements of ISO Designed and produced by Partners in Communication /11 Split and Multi-Split Systems KX6 VRF Inverter Systems

2 Contents Welcome to the 2011 Price List for Mitsubishi Heavy Industries air conditioning and heat pump systems. MHI continues to expand and develop its product range, with higher efficiencies, more technical advantages, and increased benefit for engineers and installers. Most of the traditional range of SRK fixed speed and Inverter systems is unchanged, with all products having top specification - mostly A/A energy rated - with high grade filtration, deodorising and bacteria filters. Hyper systems have been introduced with exceptional efficiency, with a record CoP of 5.56 on the SRK20ZJX wall mounted system. Many of the SRK Inverter heat pump systems can be fitted with the RC-E4 wired remote controller, using the Adaptor SC-BIKN-E. The FD Series - Cassettes, Ducted, Ceiling systems offer many advantages over competitive products, having a range of compact single fan Inverter outdoor unit for all sizes up to 14kW. There is also the very popular FD Multi Systems (twin/triple/quad) - up to 25kW - ideal for open plan areas, especially retail sites. FD - Hyper Systems have been extended, offering high CoP, and pipe lengths up to 100 metres. KX - VRF Mini Systems (11.2, 14, 15.5kW) have compact single fan outdoor units, with up to 8 indoor units connected. The extensive range of KX & KXR 2-pipe and 3-pipe systems are high specification and competitively priced. Valve Kits for Air Handler application are being introduced this year, allowing increased options of applying energy efficient KX systems to other cooling/heating plant. New this year is the inclusion of Installation Materials, copper tube, insulation, condensate pumps, wall brackets, plus tools and equipment for engineers - all available from HRP Service Centres. With Mitsubishi Heavy Industries we have the most comprehensive and competitive range, with products for nearly every application, and combining this with the huge range of products and materials from HRP, we are able to offer the best service, nationwide, to busy installers and contractors. MHI Technical Centre KNOWLEDGE EXPERIENCE UNDERSTANDING See pages for details of MHI product training Installation Commissioning Troubleshooting Maintenance Split & Multi Split Systems Performance Conditions and Terms 2 SRK-HG Wall Fixed Speed 3 SRK-ZJ/ZK Wall Standard Inverter 4 SRK-ZJX Wall Hyper Inverter 5 SRF-ZJX Floor Console Hyper Inv 6 SRR-ZJX Compact Ducted and Controls 7 SCM-ZJ Inverter Multi Systems 8 SCM Indoor Units 9 SCM Combinations 10 SCM Combinations 11 Technical Notes 12 FDTC Compact Cassette 13 FDT Cassette incl. New Hyper FDEN Ceiling incl. New Hyper FDUM Ducted incl. Hyper FDU Ducted High Static incl. Hyper FDF Floor Vertical incl. Hyper FD Multi Systems incl Hyper Multi VRF Inverter Multi Systems KX Mini 112,140, KX Side Blow 224, 280, KX 2-Pipe Outdoor Units KXR 3-Pipe Outdoor Units KX & KXR Branch Kits KX6 Indoor Units KX - New Units, Valve Kits, SAF-DX Unit, & SAF 34 Controls and Accessories KX Controls and Accessories 35 Air to Water Heat Pumps Air to Water Heat Pump Additional Information Error Codes MHI Training Installation Materials - Accessories, Tools & Refrigerant Installation Accessories from HRP Tools & Equipment 46 Refrigerants 47 1

3 Performance Conditions and Terms SRK-HG Wall Fixed Speed Nominal & UK Conditions - Nominal capacities (kw) specified in this price book are calculated under ISO-T1 (JIS) standard conditions as follows: Cooling: Indoor temperature 27 CDB, 19 CWB Outdoor temperature 35 CDB Heating: Indoor temperature 20 CDB Outdoor temperature 7 CDB, 6 CWB - UK cooling capacities (kw) specified in this price book are calculated under the following conditions: Indoor temperature 23 CDB, 16 CWB Outdoor temperature 30 CDB Electrical Supplies Power Source Ratings listed in this publication are for guidance only. Power Source Ratings for Inverter Systems should be based on the Maximum Run Current (shown in brackets in the data tables) and on the relevant Electrical Regulations. Existing Pipework Wherever the outdoor units listed below are used, installations can be carried out using existing R22 and R407C pipework according to manufacturer s instructions. Please contact 3d HRP for information on procedures and training courses. SRC40 to 60ZJX-S FDC71VNX FDC100 to 140VN(S) FDC100 to 140VN(S)X FDC200 to 250VNS Engineers must have attended the MHI Training Course Module 8 please refer to P40 Terms & Conditions All prices are subject to VAT Prices are effective from 1st May Prices are subject to change without notice. Prices are ex warehouse. Please contact 3D/HRP for delivery charges which may apply. The manufacturer has a continuous programme of product development and reserves the right to change specifications without prior notice. The information is provide for guidance only, and does not form part of a Contract. Manufacturer s specifications should be checked prior to ordering. All goods are supplied subject to HRP & 3D Terms and Conditions copies available on request. Prices are LIST (except for SRK-HG) and may be subject to agreed trade discounts. Warranty: 3 years parts only, covers replacement of faulty components provided they are returned within 30 days. Warranty is subject to installation by a qualified engineer in accordance with manufacturer s instructions, and subject to a maintenance agreement. High Wall mounted with three fan speeds Natural enzyme bacteria filter Photocatalytic deodorising filter Maximum pipe length of 15m Refrigerant fully charged for 7m pipe length Selling Category E INDOOR UNIT c/w IR Controller SRK28HG-S SRK40HG-S HRP Code NET Price OUTDOOR UNIT SRC28HG-S SRC40HG-S HRP Code NET Price SYSTEM Code SYSTEM NET Price Cooling (Nominal) kw UK Cooling kw UK Sensible Cooling kw E.E.R. (Energy Label) 3.21 (B) 3.21 (B) Heating (Nominal) kw C.O.P (Energy Label) 3.64 (B) 3.41 (B) INDOOR UNIT Exterior Dimensions (H x W x D) mm 268 x 790 x x 790 x 199 Net Weight kg Air Volume (High Speed) Cooling m3/s Air Volume (High Speed) Heating m3/s Sound Pressure Level (L/M/H) Cooling db(a) 30 / 33 / / 38 / 40 Sound Pressure Level (L/M/H) Heating db(a) 29 / 33 / / 38 / 40 OUTDOOR UNIT Exterior Dimensions (H x W x D) mm 540 x 780(+62) x x 780(+62) x 290 Net Weight kg Sound Pressure Level db(a) ELECTRICAL DATA Power Source Rating MCB A Mains Power To Indoor 230V/1ph/50Hz 230V/1ph/50Hz Interconnecting Wires 3 + E 3 + E Running Current - Cooling A Running Current - Heating A Power Input - Cooling kw Power Input - Heating kw Start Current A INSTALLATION/REFRIGERANT Ref. Piping Size o.d ins (mm) Liquid 1/4 (6.35) 1/4 (6.35) Gas 3/8 (9.52) 1/2 (12.7) Ref. Max Piping Length m Vertical Height Difference (Max) - Outdoor Unit Above Indoor Unit m Outdoor Unit Below Indoor Unit m Refrigerant Amount Precharged kg For Pipe Length Up To m 7 7 Additional Refrigerant g/m <10m = 20 >10m = 30 <10m = 20 >10m = 30 SRK-HG Low Cost systems High performance fixed speed systems. Please note: Prices are NET. SRK Fixed Speed not suitable for low ambient cooling operation without control kit. Control: Infra-red control only. Mains Power supply to INDOOR Unit. Installation Materials Copper Tube Condensate Pumps please see pages A low ambient controller should be fitted for UK cooling operation in low ambient condition, otherwise the warranty may be affected. Wall Brackets other installation accessories 2 3

4 SRK-ZJ/ZK Wall Mounted Standard Inverter SRK-ZJX Wall Mounted Hyper Inverter High Wall mounted with three fan speeds Natural enzyme and Photocatalytic filters Low ambient operation (cooling) to -15ºC Maximum pipe length up to 30m (SRK..ZK) Refrigerant fully charged for 15m pipe length Selling Category C NEW SRK 80 high capacity model (Summer 2011) See P7 for additional Controls and Adaptors INDOOR UNIT c/w IR Controller SRK25ZJ-S SRK35ZJ-S SRK50ZJ-S SRK63ZK-S SRK71ZK-S SRK80ZK-S HRP Code LIST Price TBC OUTDOOR UNIT SRC25ZJ-S SRC35ZJ-S SRC50ZJ-S SRC63ZK-S SRC71ZK-S SRC80ZK-S HRP Code LIST Price ,114 TBC SYSTEM Code SYSTEM LIST Price ,034 1,352 1,758 TBC High Performance - C.o.P. up to 5.56 High Wall mounted with three fan speeds Natural enzyme and Photocatalytic filters Low ambient operation (cooling) to -15ºC Negative Ion Generator Selling Category C INDOOR UNIT c/w IR Controller SRK20ZJX-S SRK25ZJX-S SRK35ZJX-S SRK50ZJX-S SRK60ZJX-S HRP Code LIST Price OUTDOOR UNIT SRC20ZJX-S SRC25ZJX-S SRC35ZJX-S SRC50ZJX-S SRC60ZJX-S HRP Code LIST Price ,030 1,146 SYSTEM Code SYSTEM LIST Price ,044 1,646 1,830 See P7 for additional Controls and Adaptors Cooling (Nominal) kw Cooling Range kw 1.0 to to to to to to 8.5 UK Cooling Nom kw UK Sensible Cooling Nom kw E.E.R (Energy Label) 4.03 (A) 3.47 (A) 3.23 (B) 3.58 (A) 3.29 (B) 3.02 (B) Heating (Nominal) kw Heating Range kw 1.2 to to to to to to 10.5 C.O.P (Energy Label) 4.00 (A) 4.00 (A) 3.65 (B) 3.97 (A) 3.74 (A) 3.53 (B) Cooling (Nominal) kw Cooling Range kw 0.9 to to to to to 6.8 UK Cooling Nom kw UK Sensible Cooling Nom kw E.E.R (Energy Label) 5.71 (A) 5.20 (A) 4.14 (A) 3.85 (A) 3.23 (B) Heating (Nominal) kw Heating Range kw 0.9 to to to to to 9.7 C.O.P (Energy Label) 5.56 (A) 5.26 (A) 4.48 (A) 4.44 (A) 4.07 (A) INDOOR UNIT Exterior Dimensions (H x W x D) mm 294 x 798 x x 798 x x 798 x x 1098 x x 1098 x x 1098 x 248 Net Weight kg Air Volume (UL L M H) Cooling m3/s na na na Air Volume (UL L M H) Heating m3/s na na na Sound Pressure Level (UL L M H) Cooling db(a) na / 21 / 28 / 34 na / 22 / 32 / 42 na / 33 / 42 / / 37 / 43 / / 39 / 45 / / 41 / 47 / 50 Sound Pressure Level (UL L M H) Heating db(a) na / 24 / 31 / 39 na / 25 / 37 / 43 na / 36 / 45 / / 36 / 41 / / 38 / 43 / / 40 / 45 / 48 OUTDOOR UNIT Exterior Dimensions (H x W x D) mm 540 x 780(+62) x x 780(+62) x x 800(+71) x x 880(+88) x x 880(+88) x x 880(+88) x 340 Net Weight kg Sound Pressure Level db(a) ELECTRICAL DATA Power Source Rating MCB A Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E Running Current - Cooling Nom (Max) A 3.1 (9) 4.7 (9) 6.8 (14) 8 (17) 9.7 (17) 11.9 (tba) Running Current - Heating Nom (Max) A 3.8 (9) 4.7 (9) 7 (14) 8.1 (17) 9.7 (17) 11.4 (tba) Power Input - Cooling Nom kw Power Input - Heating Nom kw Start Current A tba INSTALLATION/REFRIGERANT Ref. Piping Size o.d ins (mm) Liquid 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) Gas 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) Ref. Max Piping Length m Vertical Height Difference (Max) - Outdoor Unit Above Indoor Unit m Outdoor Unit Below Indoor Unit m Refrigerant Amount Precharged kg For Pipe Length Up To m Additional Refrigerant g/m n/a n/a INDOOR UNIT Exterior Dimensions (H x W x D) mm 309 x 890 x x 890 x x 890 x x 890 x x 890 x 220 Net Weight kg Air Volume (L/M/H) Cooling m3/s Air Volume (L/M/H) Heating m3/s Sound Pressure Level (L/M/H) Cooling db(a) 21 / 30 / / 31 / / 33 / / 38 / / 38 / 47 Sound Pressure Level (L/M/H) Heating db(a) 25 / 33 / / 34 / / 35 / / 38 / / 39 / 45 OUTDOOR UNIT Exterior Dimensions (H x W x D) mm 595 x 780(+62) x x 780(+62) x x 780(+62) x x 800(+71) x x 800(+71) x 290 Net Weight kg Sound Pressure Level db(a) ELECTRICAL DATA Power Source Rating MCB A Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E Running Current - Cooling Nom (Max) A 1.8 (8) 2.4 (8) 3.8 (8) 5.7 (14) 8.2 (14) Running Current - Heating Nom (Max) A 2.3 (8) 2.9 (8) 4.4 (8) 5.9 (14) 7.3 (14) Power Input - Cooling Nom kw Power Input - Heating Nom kw Start Current A INSTALLATION/REFRIGERANT Ref. Piping Size o.d ins (mm) Liquid 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) Gas 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) 1/2 (12.7) Ref. Max Piping Length m Vertical Height Difference (Max) - Outdoor Unit Above Indoor Unit m Outdoor Unit Below Indoor Unit m Refrigerant Amount Precharged kg For Pipe Length Up To m Additional Refrigerant g/m n/a n/a n/a

5 SRF-ZJX Floor Console Hyper Inverter SRR-ZJX Compact Ducted Hyper Inverter Floor standing or low wall mounted Pipe length up to 30m on SRF50 Downward air discharge for heating mode Refrigerant fully charged for 15m pipe length Selling Category C See P7 for additional Controls and Adaptors Compact Ducted Unit with three fan speeds Infra-red Control with 24hr timer Return Air filter included Optional condensate pump and spigot kit Refrigerant fully charged for 15m pipe length Selling Category C INDOOR UNIT c/w IR Controller SRF25ZJX-S SRF35ZJX-S SRF50ZJX-S HRP Code LIST Price OUTDOOR UNIT SRC25ZJX-S SRC35ZJX-S SRC50ZJX-S HRP Code LIST Price ,030 SYSTEM Code SYSTEM LIST Price 1,189 1,331 1,745 Full range of Installation Accessories available from HRP (see p42-45): Copper Tube INDOOR UNIT c/w IR Controller SRR25ZJ-S SRR35ZJ-S HRP Code LIST Price OUTDOOR UNIT SRC25ZJX-S SRC35ZJX-S HRP Code LIST Price SYSTEM Code SYSTEM LIST Price 1,242 1,384 Accessories for SRK-ZJ/ZK/ZJX, SRF & SRR HRP Code List Price SC-BIKN-E Adaptor for Wired Remote RC-E4 Remote Control - Wired PJA504A178XR 6-Wire Adaptor BBF12 Back Return Filter - SRR Cooling (Nominal) kw Cooling Range kw 0.9 to to to 5.5 UK Cooling Nom kw UK Sensible Cooling Nom kw E.E.R (Energy Label) 4.80 (A) 3.93 (A) 3.60 (A) Heating (Nominal) kw Heating Range kw 0.9 to to to 7.0 C.O.P (Energy Label) 4.70 (A) 4.00 (A) 3.90 (A) Operating Range (Outdoor Air) Cooling oc DB -15 to 46 Operating Range (Outdoor Air) Heating oc WB -15 to 21 Wall Brackets Cooling (Nominal) kw Cooling Range kw 0.9 to to 5.1 UK Cooling Nom kw UK Sensible Cooling Nom kw E.E.R. (Energy Label) 4.31 (A) 3.24 (B) Heating (Nominal) kw Heating Range kw 0.9 to to 5.1 C.O.P (Energy Label) 4.53 (A) 3.82 (A) Operating Range (Outdoor Air) Cooling ºC DB - 5 to 46 Operating Range (Outdoor Air) Heating ºC WB -5 to 21 INDOOR UNIT Exterior Dimensions (H x W x D) mm 600 x 860 x x 860 x x 860 x 238 Net Weight kg Air Volume (L/M/H) Cooling m3/s Air Volume (L/M/H) Heating m3/s Sound Pressure Level (L/M/H) Cooling db(a) 26 / 32 / / 34 / / 39 / 47 Sound Pressure Level (L/M/H) Heating db(a) 28 / 35 / / 36 / / 39 / 47 OUTDOOR UNIT Exterior Dimensions (H x W x D) mm 595 x 780 (+62) x x 780 (+62) x x 800(+71) x 290 Net Weight kg Sound Pressure Level db(a) ELECTRICAL DATA Power Source Rating MCB A Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E Running Current - Cooling Nom (Max) A 2.5 (8) 3.9 (8) 6.1 (14) Running Current - Heating Nom (Max) A 3.4 (8) 4.9 (8) 6.8 (14) Power Input - Cooling Nom kw Power Input - Heating Nom kw Start Current A INSTALLATION/REFRIGERANT Ref. Piping Size o.d ins (mm) Liquid 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) Gas 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) Ref. Max Piping Length m Vertical Height Difference (Max) - Outdoor Unit Above Indoor Unit m Outdoor Unit Below Indoor Unit m Refrigerant Amount Precharged kg For Pipe Length Up To m Additional Refrigerant g/m n/a n/a 20 Condensate Pumps INDOOR UNIT Exterior Dimensions (H x W x D) mm 230 x 740 x x 740 x 455 Net Weight kg Air Volume (L - M - H) Cooling m3/s Air Volume (L - M - H) Heating m3/s Sound Pressure Level (L/M/H) Cooling db(a) 29 / 35 / / 37 / 42 Sound Pressure Level (L/M/H) Heating db(a) 31 / 38 / / 40 / 43 OUTDOOR UNIT Exterior Dimensions (H x W x D) mm 595 x 780(+62) x x 780(+62) x 290 Net Weight kg Sound Pressure Level db(a) ELECTRICAL DATA Power Source Rating MCB A Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz Interconnecting Wires 3 + E 3 + E Running Current - Cooling Nom (Max) A 2.8 (8) 4.7 (8) Running Current - Heating Nom (Max) A 3.6 (8) 4.8 (8) Power Input - Cooling Nom kw Power Input - Heating Nom kw Start Current A 4 5 INSTALLATION/REFRIGERANT Ref. Piping Size o.d ins (mm) Liquid 1/4 (6.35) 1/4 (6.35) Gas 3/8 (9.52) 3/8 (9.52) Ref. Max Piping Length m Vertical Height Difference (Max) - Outdoor Unit Above Indoor Unit m Outdoor Unit Below Indoor Unit m Refrigerant Amount Precharged kg For Pipe Length Up To m Additional Refrigerant g/m n/a n/a 6 7

6 SCM-ZJ Inverter Multi Systems Up to six indoor units on larger systems Individually controlled indoor units All indoor units operate in same Mode Choice of Wall, Cassette, Ducted, Floor units Outdoor units Selling Category C SCM45, SCM60 SCM80 SCM100, SCM125 OUTDOOR UNIT SCM45ZJ-S SCM60ZJ-S SCM80ZJ-S SCM100ZJ-S SCM125ZJ-S HRP Code LIST Price 1,119 1,769 2,197 TBC TBC Cooling (Nominal) kw TBC TBC Cooling Range kw 1.8 to to to 9.2 TBC TBC E.E.R (Energy Label) 4.33 (A) 4.20 (A) 3.70 (A) TBC TBC Heating (Nominal) kw TBC TBC Heating Range kw 1.4 to to to 9.8 TBC TBC C.O.P (Energy Label) 4.67 (A) 4.50 (A) 4.12 (A) TBC TBC Exterior Dimensions (H x W x D) mm 640 x 850(+65) x x 850(+65) x x 880(+73) x 340 TBC TBC Net Weight kg TBC TBC Sound Pressure Level db(a) TBC TBC Number of Indoor Units Min-Max TBC TBC ELECTRICAL DATA Power Source Rating MCB A Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz TBC TBC Interconnecting Wires 3 + E (x2) 3 + E (x3) 3 + E (x4) TBC TBC Running Current - Cooling Nom (Max) A 4.6 (14) 6.5 (17) 9.4 (20) TBC TBC Running Current - Heating Nom (Max) A 5.3 (14) 6.8 (17) 10 (20) TBC TBC Power Input - Cooling Nom kw TBC TBC Power Input - Heating Nom kw TBC TBC Start Current A TBC TBC INSTALLATION/REFRIGERANT Ref. Piping Size o.d ins (mm) Liquid 1/4 (6.35) x 2 1/4 (6.35) x 3 1/4 (6.35) x 4 TBC TBC Gas 3/8 (9.52) x 2 3/8 (9.52) x 3 3/8 (9.52) x 4 TBC TBC Ref. Max Piping Length (Unit/Total) m 25/30 25/40 25/70 TBC TBC Vertical Height Difference (Max) - Outdoor Unit Above Indoor Unit m TBC TBC - Outdoor Unit Below Indoor Unit m TBC TBC Refrigerant Amount Precharged kg TBC TBC - For Pipe Length Up To m TBC TBC Additional Refrigerant g/m TBC TBC TBC Mote: Mains Power to Outdoor Unit. Interconnecting 3core+ E to each Indoor Unit Simple interconnecting pipe layout with each Indoor Unit individually connected to Outdoor Unit Indoor units Selling Category C SRKZJ FDTC CASSETTE c/w WIRED Controller RC-E4 FDTC25VD FDTC35VD FDTC50VD FDTC60VD Fascia Panel TC-PSA-25W-E TC-PSA-25W-E TC-PSA-25W-E TC-PSA-25W-E Code (Cassette + Fascia + RC-E4 Controller) LIST Price (Cass. + Fascia + Controller) Cooling (Nominal) kw Heating (Nominal) kw Air Volume (Heating - High Speed) m3/s Sound Pressure Level (Heating - High Speed) db(a) Exterior Dimensions (H x W x D) Unit mm 248 x 570 x x 570 x x 570 x x 570 x 570 Panel mm 35 x 700 x x 700 x x 700 x x 700 x 700 Net Weight Unit (Fascia Panel) kg 15 (3.5) 15 (3.5) 15 (3.5) 15 (3.5) Ref. Piping Size o.d ins (mm) Liquid 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) Gas 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) 1/2 (12.7) SRF FLOOR STANDING (c/w IR Controller) SRF25ZJX-S SRF35ZJX-S SRF50ZJX-S Code LIST Price Cooling (Nominal) kw Heating (Nominal) kw Air Volume (Heating - High Speed) m3/s Sound Pressure Level (Heating - High Speed) db(a) Exterior Dimensions (H x W x D) mm 600 x 860 x x 860 x x 860 x 238 Net Weight kg Ref. Piping Size o.d ins (mm) Liquid 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) Gas 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) FDTC SRF SRR FDTC Indoor units SRR SRR DUCTED c/w IR Controller SRR25ZJ-S SRR35ZJ-S SRR50ZJ-S SRR60ZJ-S HRP Code LIST Price Cooling (Nominal) kw Heating (Nominal) kw Air Volume (Heating - High Speed) m3/s Sound Pressure Level (Heating - High Speed) db(a) Exterior Dimensions (H x W x D) mm 230 x 740 x x 740 x x 740 x x 740 x 455 Net Weight kg Ref. Piping Size o.d ins (mm) Liquid 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) Gas 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) 1/2 (12.7) SRK WALL MOUNTED c/w IR Controller SRK25ZJ-S SRK35ZJ-S SRK50ZJ-S Code LIST Price Cooling (Nominal) kw Heating (Nominal) kw Air Volume (Heating - High Speed) m3/s Sound Pressure Level (Heating - High Speed) db(a) Exterior Dimensions (H x W x D) mm 294 x 798 x x 790 x x 790 x 199 Net Weight kg Ref. Piping Size o.d ins (mm) Liquid 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) Gas 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) SRKZJ AVAILABLE SUMMER 2011 FDEN50VD Ceiling Suspended & FDUM50VD Ducted Indoor Units for connection to SCM Multi Systems 8 9

7 Inverter multi system combinations SCM Combinations can be selected from the Indoor Unit models listed on Pages 8-9. Outdoor Indoor Unit Type Indoor Cooling Heating Unit SRK FDTC SRR SRF Model kw kw SCM45ZJ-S Indoor A Indoor B SCM45ZJ-S Indoor A Indoor B SCM45ZJ-S Indoor A Indoor B SCM45ZJ-S Indoor A Indoor B SCM45ZJ-S Indoor A Indoor B Outdoor Indoor Unit Type Indoor Cooling Heating Unit SRK FDTC SRR SRF Model kw kw SCM60ZJ-S Indoor A Indoor B Indoor C SCM60ZJ-S Indoor A Indoor B Indoor C SCM60ZJ-S Indoor A Indoor B Indoor C SCM60ZJ-S Indoor A Indoor B Indoor C SCM60ZJ-S Indoor A Indoor B Indoor C SCM60ZJ-S Indoor A Indoor B Indoor C SCM60ZJ-S Indoor A Indoor B Indoor C SCM60ZJ-S Indoor A Indoor B Indoor C SCM60ZJ-S Indoor A Indoor B Indoor C SCM60ZJ-S Indoor A Indoor B Indoor C SCM60ZJ-S Indoor A Indoor B Indoor C SCM60ZJ-S Indoor A Indoor B Indoor C SCM60ZJ-S Indoor A Indoor B Indoor C Outdoor Indoor Unit Type Indoor Cooling Heating Unit SRK FDTC SRR SRF Model kw kw SCM80ZJ-S Indoor A Indoor B Indoor C Indoor D SCM80ZJ-S Indoor A Indoor B Indoor C Indoor D SCM80ZJ-S Indoor A Indoor B Indoor C Indoor D SCM80ZJ-S Indoor A Indoor B Indoor C Indoor D SCM80ZJ-S Indoor A Indoor B Indoor C Indoor D SCM80ZJ-S Indoor A Indoor B Indoor C Indoor D SCM80ZJ-S Indoor A Indoor B Indoor C Indoor D SCM80ZJ-S Indoor A Indoor B Indoor C Indoor D SCM80ZJ-S Indoor A Indoor B Indoor C Indoor D SCM80ZJ-S Indoor A Indoor B Indoor C Indoor D SCM80ZJ-S Indoor A Indoor B Indoor C Indoor D SCM80ZJ-S Indoor A Indoor B Indoor C Indoor D SCM80ZJ-S Indoor A Indoor B Indoor C Indoor D SCM80ZJ-S Indoor A Indoor B Indoor C Indoor D SCM80ZJ-S Indoor A Indoor B Indoor C Indoor D For SCM 100 & 125 Combinations - please contact 3D/HRP 11

8 Technical Notes FDTC Compact Cassette MHI Cassette Systems FDT Standard & FDTC Compact (600 x 600) New product features now include Independent Louver Control, allowing air flow patterns to be customised to the size and shape of each conditioned space. This independent control can also help to deal with unwanted drafts. The position of each louver can be set on the Wired Controller RC-E4 4-way discharge with individual louver control Fits 600mm x 600mm ceiling grid Branch duct facility Low ambient operation to -15ºC Refrigerant charged up to 30m pipe length Selling Category C INDOOR UNIT FDTC25VD FDTC35VD FDTC40VD FDTC50VD FDTC60VD HRP Code LIST Price FASCIA PANEL TC-PSA-25W-E TC-PSA-25W-E TC-PSA-25W-E TC-PSA-25W-E TC-PSA-25W-E HRP Code LIST Price WIRED CONTROLLER RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 HRP Code LIST Price OUTDOOR UNIT SRC25ZJX-S SRC35ZJX-S SRC40ZJX-S SRC50ZJX-S SRC60ZJX-S HRP Code LIST Price ,030 1,146 (option) RC-E4 Multi Function Wired Controller The RC-E4 (623194) is supplied as standard on all FD split systems. As well as the normal function of Set Temperature adjustment and Fan Speed selection, the wired controller has the following technical advantages: Integral temperature sensor, which can be used as an alternative to the the indoor unit return air sensor Digital display of operating data, including compressor frequency and speed, valve openings, system pressures and temperatures at various points Full diagnosis of system failure - see P38-39 for Error Codes Facility to eliminate selected display data Group Control for up to 16 systems The RC-E4 can also be used on all SRK Inverter systems, using Adaptor Kit SC-BIKN-E RCH-E3 Simplified Controller is an alternative wired controller designed for hotel rooms, offices and other sreas, where full functions are not required. 6-Way Adaptor CnT This low cost Adaptor(633086) allows on/off (12v) switching via a volt free contact. It plugs into the indoor unit pcb on FD series indoor units, including all of the KX range. It also plugs into the SC-BIKN-E adaptor for SRK-JZ/ZK/ZJX, SRF & SRR. The adaptor allows low voltage output signals to indicate: Cooling, Heating, and Common Fault signal. RC-E4 Controller with Integral Temperature Sensor RCH-E3 Simplified Wired Controller (hotel) - also has Integral Sensor FDTC Space Collars Selling Category B Space Collar - for restricted ceiling height (FDTC Cassettes) HRP Code List Price 50mm height mm height mm height HRP SYSTEM Code SYSTEM LIST Price 1,294 1,362 1,572 1,795 1,963 Cooling (Nominal) kw Cooling Range kw 0.9 to to to to to 5.6 UK Cooling Nom kw UK Sensible Cooling Nom kw E.E.R (Energy Label) 4.25 (A) 3.36 (A) 3.85 (A) 3.21 (C) 3.21 (C) Heating (Nominal) kw Heating Range kw 0.9 to to to to to 6.3 C.O.P (Energy Label) 4.11 (A) 3.66 (B) 4.09 (A) 3.72 (A) 3.72 (A) INDOOR UNIT Exterior Dimensions (H x W x D) Unit mm 248 x 570 x x 570 x x 570 x x 570 x x 570 x 570 Panel mm 35 x 700 x x 700 x x 700 x x 700 x x 700 x 700 Net Weight Unit (Fascia Panel) kg 15 (3.5) 15 (3.5) 15 (3.5) 15 (3.5) 15 (3.5) Air Volume* (L - M - H - EH) Cooling m3/s Air Volume* (L - M - H - EH) Heating m3/s Sound Pressure Level (L/M/H - EH) Cooling db(a) 29 / 32 / 36 / / 36 / 40 / / 36 / 42 / / 36 / 42 / / 39 / 46 / 47 Sound Pressure Level (L/M/H - EH) Heating db(a) 29.5 / 33 / 38 / / 35 / 42 / / 36 / 42 / / 36 / 42 / / 39 / 46 / 47 OUTDOOR UNIT Exterior Dimensions (H x W x D) mm 595 x 780(+62) x x 780(+62) x x 800(+71) x x 800(+71) x x 800(+71) x 290 Net Weight kg Sound Pressure Level db(a) ELECTRICAL DATA Power Source Rating MCB A Mains Power To Outdoor 230v/1ph/50Hz 230v/1ph/50Hz 230v/1ph/50Hz 230v/1ph/50Hz 230v/1ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E Running Current - Cooling Nom (Max) A 2.9 (9) 4.7 (9) 4.6 (12) 6.9 (14) 8.3 (14) Running Current - Heating Nom (Max) A 4 (9) 5.1 (9) 4.9 (12) 6.4 (14) 8.7 (14) Power Input - Cooling Nom kw Power Input - Heating Nom kw Start Current A INSTALLATION/REFRIGERANT Ref. Piping Size o.d ins (mm) Liquid 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) Gas 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) Ref. Max Piping Length m Vertical Height Difference (Max) - Outdoor Unit Above Indoor Unit m Outdoor Unit Below Indoor Unit m Refrigerant Amount Precharged kg For Pipe Length Up To m Additional Refrigerant g/m n/a n/a * If wireless remote controller is used, only 3 fan speeds are available: LOW/MED/HIGH. For FDTC Space Collars - please refer to Page 12 13

9 FDT Cassette Inverter Systems FDT Cassette Hyper Inverter Systems 4-way discharge with individual louver control Wired Contrller standard, Infra-red option Branch duct facility and fresh air inlet Low ambient operation to -15ºC Refrigerant charged up to 30m pipe length Selling Category -B FDT 1-Phase Systems Standard Option FDT 3-Phase Systems INDOOR UNIT FDT40VD FDT50VD FDT60VD FDT71VD FDT100VD FDT125VD FDT140VD FDT100VD FDT125VD FDT140VD HRP Code LIST Price , ,158 FASCIA PANEL T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E HRP Code LIST Price WIRED CONTROLLER RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 HRP Code LIST Price OUTDOOR UNIT SRC40ZJX-S SRC50ZJX-S SRC60ZJX-S FDC71VNX FDC100VN FDC125VN FDC140VN FDC100VS (3 phase) FDC125VS (3 phase) FDC140VS (3 phase) HRP Code LIST Price 823 1,030 1,146 1,523 1,784 1,928 2,221 1,784 1,928 2,221 HRP SYSTEM Code SYSTEM LIST Price 1,572 1,784 1,978 2,428 2,822 3,135 3,593 2,822 3,135 3,593 Cooling (Nominal) kw Cooling Range kw 1.1 to to to to to to to to to to 14.5 UK Cooling Nom kw UK Sensible Cooling Nom kw E.E.R (Energy Label) 4.30 (A) 3.88 (A) 3.68 (A) 3.48 (A) 3.62 (A) 3.09 (B) 2.81 (C) 3.62 (A) 3.09 (B) 2.81 (C) Heating (Nominal) kw Heating Range kw 0.6 to to to to to to to to to to 16.5 C.O.P (Energy Label) 4.25 (A) 4.19 (A) 3.94 (A) 4.12 (A) 4.09 (A) 3.71 (A) 3.50 (B) 4.09 (A) 3.71 (A) 3.50 (B) INDOOR UNIT Exterior Dimensions (H x W x D) Unit mm 246 x 840 x x 840 x x 840 x x 840 x x 840 x x 840 x x 840 x x 840 x x 840 x x 840 x 840 Panel mm 35 x 950 x x 950 x x 950 x x 950 x x 950 x x 950 x x 950 x x 950 x x 950 x x 950 x 950 Net Weight Unit (Fascia Panel) kg 22 (5.5) 22 (5.5) 24 (5.5) 24 (5.5) 27 (5.5) 27 (5.5) 27 (5.5) 27 (5.5) 27 (5.5) 27 (5.5) Air Volume (L - M - H -EH)* m3/s Sound Pressure Level (L / M /H / EH) db(a) 30 / 31 / 33 / / 31 / 33 / / 31 / 33 / / 33 / 35 / / 37 / 40 / / 40 / 42 / / 41 / 43 / / 37 / 40 / / 40 / 42 / / 41 / 43 / 51 OUTDOOR UNIT Exterior Dimensions (H x W x D) mm 640 x 800(+71) x x 800(+71) x x 800(+71) x x 880(+88) x x 970 x x 970 x x 970 x x 970 x x 970 x x 970 x 370 Net Weight kg Sound Pressure Level db(a) ELECTRICAL DATA Power Source Rating MCB A per phase 20 per phase 20 per phase Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E Running Current - Cooling Nom (Max) A 4.1 (12) 5.7 (15) 7.0 (15) 9.1 (24) 12.1 (24) 17.6 (24) 22 (24) 4.2 (15) per phase 5.9 (15) per phase 7.4 (15) per phase Running Current - Heating Nom (Max) A 5.2 (12) 5.7 (15) 8.2 (15) 8.7 (24) 12 (24) 16.6 (24) 20.2 (24) 4.2 (15) per phase 5.5 (15) per phase 6.7 (15) per phase Power Input - Cooling Nom kw Power Input - Heating Nom kw Start Current A per phase 5 per phase 5 per phase INSTALLATION/REFRIGERANT Ref. Piping Size o.d ins (mm) Liquid 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) Gas 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) Ref. Max Piping Length m Vertical Height Difference (Max) - Outdoor Unit Above Indoor Unit m Outdoor Unit Below Indoor Unit m Refrigerant Amount Precharged kg For Pipe Length Up To m Additional Refrigerant g/m NEW Pipe length up to 100m on Hyper Systems 100, 125, 140 FDT Hyper 1-Phase (3ph - p.o.a.) FDT100VD FDT125VD FDT140VD ,158 T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E RC-E4 RC-E4 RC-E FDC100VNX FDC125VNX FDC140VNX ,087 2,294 2, ,125 3,501 4, to to to (A) 3.81 (A) 3.34 (A) to to to (A) 4.08 (A) 3.81 (A) 298 x 840 x x 840 x x 840 x x 950 x x 950 x x 950 x (5.5) 27 (5.5) 27 (5.5) / 37 / 40 / / 40 / 42 / / 41 / 43 / x 970 x x 970 x x 970 x V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 3 + E 3 + E 3 + E 11.1 (24) 14.6 (24) 18.6 (26) 11.4 (24) 15.2 (24) 18.6 (26) per phase 5 per phase 5 per phase 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) FDT MULTI SPLIT Systems up to 25kW Installation Accessories - Copper Tube Pipe Supports Condensate Pumps & Hose Cables - please see P42 RC-E4 Remote Controller includes internal temperature sensor, which can be used as an alternative to the unit return air sensor. Selling Category - B Accessories HRP Code 6-Way Adaptor for Timeclock & BMS List Price Remote Controller & Receiver Kit Network Adaptor SC-ADN-E Space Collar - for restricted ceiling height - FDT Cassettes only HRP Code List Price 50mm height mm height mm height Condensing Unit Drain Kit - please refer to P24 Insulation Wall Brackets Isolators TECHNICAL NOTES Group Control is possible (up to 16 systems) using one RC-E4 Remote Controller. Elbow & Grometts * If wireless remote controller is used, only 3 fan speeds are available: LOW/MED/HIGH

10 FDEN Ceiling Inverter Systems Wired Controller standard, Infra-red option Slim design - 210mm on most models Low ambient operation to -15ºC Refrigerant charged up to 30m pipe length FDEN Ceiling Hyper Inverter Systems NEW Pipe length up to 100m on Hyper Systems 100, 125, 140 Selling Category -B FDEN 1-Phase Systems FDEN 3-Phase Systems INDOOR UNIT FDEN40VD FDEN50VD FDEN60VD FDEN71VD FDEN100VD FDEN125VD FDEN140VD FDEN100VD FDEN125VD FDEN140VD HRP Code LIST Price ,300 1, ,300 1,496 WIRED CONTROLLER RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 HRP Code LIST Price OUTDOOR UNIT SRC40ZJX-S SRC50ZJX-S SRC60ZJX-S FDC71VNX FDC100VN FDC125VN FDC140VN FDC100VS (3 phase) FDC125VS (3 phase) FDC140VS (3 phase) HRP Code LIST Price 823 1,030 1,146 1,523 1,784 1,928 2,221 1,784 1,928 2,221 (option) FDEN Hyper 1-Phase (3ph - p.o.a.) FDEN100VD FDEN125VD FDEN140VD ,300 1,496 RC-E4 RC-E4 RC-E FDC100VNX FDC125VNX FDC140VNX ,087 2,294 2,643 FDEN MULTI SPLIT Systems up to 25kW - please refer to P24 HRP SYSTEM Code SYSTEM LIST Price 1,522 1,738 1,923 2,412 2,810 3,291 3,780 2,810 3,291 3,780 Cooling (Nominal) kw Cooling Range kw 1.1 to to to to to to to to to to 14.5 UK Cooling Nom kw UK Sensible Cooling Nom kw E.E.R (Energy Label) 3.92 (A) 3.27 (B) 3.15 (B) 3.36 (A) 3.51 (A) 2.80 (D) 2.41 (E) 3.51 (A) 2.80 (D) 2.41 (E) Heating (Nominal) kw Heating Range kw 0.6 to to to to to to to to to to 16.5 C.O.P (Energy Label) 4.09 (A) 3.70 (A) 3.58 (B) 3.79 (A) 3.77 (A) 3.43 (B) 3.25 (C) 3.77 (A) 3.43 (B) 3.25 (C) INDOOR UNIT Exterior Dimensions (H x W x D) mm 210 x 1070 x x 1070 x x 1320 x x 1320 x x1620 x x 1620 x x 1620 x x1620 x x 1620 x x 1620 x 690 Net Weight kg Air Volume* (L - M - H -EH) m3/s Sound Pressure Level (L / M /H / EH) db(a) 37 / 38 / 39 / / 38 / 39 / / 39 / 41 / / 39 / 41 / / 41 / 44 / / 44 / 46 / / 44 / 46 / / 41 / 44 / / 44 / 46 / / 44 / 46 / 50 OUTDOOR UNIT Exterior Dimensions (H x W x D) mm 640 x 800(+71) x x 800(+71) x x 800(+71) x X 880(+88) X x 970 x x 970 x x 970 x x 970 x x 970 x x 970 x 370 Net Weight kg Sound Pressure Level db(a) ELECTRICAL DATA Power Source Rating MCB A per phase 20 per phase 20 per phase Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E Running Current - Cooling Nom (Max) A 4.7 (12) 7.1 (14) 8.7 (14) 9.4 (17) 12.5 (24) 19.5 (24) 25.6 (26) 4.2 (15) per phase 6.8 (15) per phase 8.6 (15) per phase Running Current - Heating Nom (Max) A 5.1 (12) 7.0 (14) 9.4 (14) 9.4 (17) 13 (24) 17.9 (24) 22.1 (26) 4.3 (15) per phase 6.3 (15) per phase 7.2 (15) per phase Power Input - Cooling Nom kw Power Input - Heating Nom kw Start Current A per phase 5 per phase 5 per phase INSTALLATION/REFRIGERANT Ref. Piping Size o.d ins (mm) Liquid 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) Gas 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) Ref. Max Piping Length m Vertical Height Difference (Max) - Outdoor Unit Above Indoor Unit m Outdoor Unit Below Indoor Unit m Refrigerant Amount Precharged kg For Pipe Length Up To m Additional Refrigerant g/m * If wireless remote controller is used, only 3 fan speeds are available: LOW/MED/HIGH. TECHNICAL NOTE: The indoor unit comes set-up for use with an IR controller. When using the RC-E4 or RCH-E3 wired controller, please disconnect the IR PCB from the AB connection on the indoor unit ,113 3,657 4, to to to (A) 3.24 (B) 2.81 (C) to to to (A) 3.71 (A) 3.41 (B) 250 x1620 x x 1620 x x 1620 x / 41 / 44 / / 44 / 46 / / 44 / 46 / x 970 x x 970 x x 970 x V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 3 + E 3 + E 3 + E 12.4 (24) 17.1 (26) 22.1 (26) 12.8 (24) 16.7 (26) 20.8 (26) /8 (9.52) 3/8 (9.52) 3/8 (9.52) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) Installation Accessories - Copper Tube Pipe Supports Condensate Pumps & Hose Cables - please see P42 Accessories Condensing Unit Drain Kit Insulation Wall Brackets Isolators TECHNICAL NOTES Group Control is possible (up to 16 systems) using one RC-E4 Remote Controller. RC-E4 Remote Controller includes internal temperature sensor, which can be used as an alternative to the unit return air sensor. HRP Code 6-Way Adaptor for Timeclock & BMS Remote Control Infrared RCN-E1R Network Adaptor SC-ADN-E Elbow & Grometts List Price 16 17

11 FDUM Ducted Inverter Systems Medium static horizontal ducted units Condensate lift pump included Option of bottom horizontal return air Low ambient operation to -15ºC Refrigerant charged up to 30m pipe length See opposite page for Filters/Frames FDUM Ducted Hyper Inverter Systems NEW Pipe length up to 100m on Hyper Systems 100, 125, 140 Selling Category -B FDUM 1-Phase Systems FDUM 3-Phase Systems FDUM Hyper 1-Phase (3ph - p.o.a.) INDOOR UNIT FDUM50VD FDUM60VD FDUM71VD FDUM100VD FDUM125VD FDUM140VD FDUM100VD FDUM125VD FDUM140VD HRP Code LIST Price ,076 1,268 1,280 1,076 1,268 1,280 WIRED CONTROLLER RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 HRP Code LIST Price OUTDOOR UNIT SRC50ZJX-S SRC60ZJX-S FDC71VNX FDC100VN FDC125VN FDC140VN FDC100VS (3 phase) FDC125VS (3 phase) FDC140VS (3 phase) HRP Code LIST Price 1,030 1,146 1,523 1,784 1,928 2,221 1,784 1,928 2,221 FDUM100VD FDUM125VD FDUM140VD ,076 1,268 1,280 RC-E4 RC-E4 RC-E FDC100VNX FDC125VNX FDC140VNX ,087 2,294 2,643 FDUM MULTI SPLIT Systems up to 25kW - please refer to P24 HRP SYSTEM Code SYSTEM LIST Price 1,606 1,783 2,355 2,923 3,259 3,564 2,923 3,259 3,564 Cooling (Nominal) kw Cooling Range kw 1.1 to to to to to to to to to 14.5 UK Cooling Nom kw UK Sensible Cooling Nom kw E.E.R (Energy Label) 3.29 (B) 3.09 (B) 3.32 (A) 3.57 (A) 3.10 (B) 2.83 (C) 3.57 (A) 3.10 (B) 2.83 (C) 3.57 (A) Heating (Nominal) kw Heating Range kw 2.5 to to to to to to to to to 16.5 C.O.P (Energy Label) 3.83 (A) 3.42 (B) 3.70 (A) 4.04 (A) 3.68 (B) 3.26 (C) 4.04 (A) 3.68 (B) 3.26 (C) INDOOR UNIT Exterior Dimensions (H x W x D) mm 299 x 750 x x 950 x x 950 x x 1370 x x 1370 x x 1370 x x 1370 x x 1370 x x 1370 x 635 External Static Pressure (Standard / Max) Pa 50 / / / / / / / / / 85 No. Of Supply Air Spigots mm 2 x x x x x x x x x 200 Net Weight kg Air Volume* (L - M - H -EH) m3/s Sound Pressure Level (L / M /H / EH) db(a) 28 / 31 / 34 / / 31 /34 / / 32 / 35 / / 35 / 37 / / 36 / 38 / / 36 / 38 / / 35 / 37 / / 36 / 38 / / 36 / 38 / 41 OUTDOOR UNIT Exterior Dimensions (H x W x D) mm 640 x 800(+71) x x 800(+71) x x 880(+88) x x 970 x x 970 x x 970 x x 970 x x 970 x x 970 x 370 Net Weight kg Sound Pressure Level db(a) ELECTRICAL DATA Power Source Rating MCB A per phase 20 per phase 20 per phase Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E Running Current - Cooling Nom (Max) A 6.7 (14) 8.2 (14) 9.5 (17) 12.5 (24) 18.3 (24) 23.2 (26) 4.2 (15) per phase 6.1 (15) per phase 7.6 (15) per phase Running Current - Heating Nom (Max) A 6.3 (14) 9.0 (14) 9.6 (17) 12.4 (24) 17.0 (24) 22.3 (26) 4.1 (15) per phase 5.7 (15) per phase 7.4 (15) per phase Power Input - Cooling Nom kw Power Input - Heating Nom kw Start Current A per phase 5 per phase 5 per phase INSTALLATION/REFRIGERANT Ref. Piping Size o.d ins (mm) Liquid 1/4 (6.35) 1/4 (6.35) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) Gas 1/2 (12.7) 1/2 (12.7) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) Ref. Max Piping Length m Vertical Height Difference (Max) - Outdoor Unit Above Indoor Unit m Outdoor Unit Below Indoor Unit m Refrigerant Amount Precharged kg For Pipe Length Up To m Additional Refrigerant g/m * If wireless remote controller is used, only 3 fan speeds are available: LOW/MED/HIGH. Return Air Filter Kit Not included ,226 3,625 3, to to to (A) 3.45 (A) 3.23 (B) to to to (A) 3.71 (A) 3.41 (B) 350 x 1370 x x 1370 x x 1370 x / / / 85 4 x x x / 35 / 37 / / 36 / 38 / / 36 / 38 / x 970 x x 970 x x 970 x V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 3 + E 3 + E 3 + E 12.1 (24) 16.1 (26) 19.3 (26) 13.1 (24) 16.7 (26) 20.8 (26) /8 (9.52) 3/8 (9.52) 3/8 (9.52) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) Technical Note: When designing ductwork and filtration, always refer to manufacturer's Fan Curves. Installation Accessories - Copper Tube Pipe Supports Condensate Pumps & Hose Cables - please see P42 TECHNICAL NOTES Insulation Wall Brackets Isolators Group Control is possible (up to 16 systems) using one RC-E4 Remote Controller. RC-E4 Remote Controller includes internal temperature sensor, which can be used as an alternative to the unit return air sensor. Accessories HRP Code List Price 6-Way Adaptor for Timeclock & BMS Remote Control (IR) & Receiver Kit Network Adaptor SC-ADN-E Filter kit FDUM 50 UM-FL1E Filter kit FDUM UM-FL2E Filter kit FDUM UM-FL3E

12 FDU Ducted High Static Inverter Systems High static (up to 200Pa) horizontal ducted units Gravity condensate drain Large capacity systems up to 25kW cooling Low ambient operation to - 15ºC Refrigerant charged up to 30m pipe length FDU Ducted Hyper Inverter Systems NEW Pipe length up to 100m on Hyper Systems 100, 125, 140 Selling Category -B FDU 1-Phase Systems FDU 3-Phase Systems INDOOR UNIT FDU71VD FDU100VD FDU125VD FDU140VD FDU100VD FDU125VD FDU140VD FDU200VD FDU250VD HRP Code LIST Price ,228 1, ,228 1,231 2,633 2,908 WIRED CONTROLLER RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 HRP Code LIST Price OUTDOOR UNIT FDC71VNX FDC100VN FDC125VN FDC140VN FDC100VS (3 phase) FDC125VS (3 phase) FDC140VS (3 phase) FDC200VS (3 phase) FDC250VS (3 phase) HRP Code LIST Price 1,523 1,784 1,928 2,221 1,784 1,928 2,221 3,101 3,404 HRP SYSTEM Code SYSTEM LIST Price 2,345 2,818 3,219 3,515 2,818 3,219 3,515 5,797 6,375 Cooling (Nominal) kw Cooling Range kw 3.2 to to to to to to to to to 28.0 UK Cooling Nom kw UK Sensible Cooling Nom kw E.E.R (Energy Label) 3.30 (A) 3.47 (A) 3.09 (B) 2.83 (C) 3.47 (A) 3.09 (B) 2.83 (C) 3.03 (B) 2.52 (E) Heating (Nominal) kw Heating Range kw 3.6 to to to to to to to to to 31.5 C.O.P (Energy Label) 3.72 (A) 3.75 (A) 3.69 (B) 3.61 (B) 3.75 (A) 3.69 (B) 3.61 (B) 3.68 (B) 3.29 (C) INDOOR UNIT Exterior Dimensions (H x W x D) mm 297 x 850 x x 1370 x x 1370 x x 1370 x x 1370 x x 1370 x x 1370 x x 1570 x x 1570 x 830 External Static Pressure (Standard / Max) Pa 50 / / / / / / / / / 200 Size Of Supply Air Spigot (H x W) mm 244 x x x x x x x x x 1450 Net Weight kg Air Volume (L - H) m3/s Sound Pressure Level (L / H) db(a) 37 / / / / / / / OUTDOOR UNIT Exterior Dimensions (H x W x D) mm 750 x 880(+88) x x 970 x x 970 x x 970 x x 970 x x 970 x x 970 x x 970 x x 970 x 370 Net Weight kg Sound Pressure Level db(a) ELECTRICAL DATA Power Source Rating MCB A per phase 20 per phase 20 per phase 32 per phase 32 per phase Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E Running Current - Cooling Nom (Max) A 9.6 (17) 12.7 (25) 17.8 (27) 21.7 (28) 4.3 (15) per phase 6.1 (15) per phase 7.4 (15) per phase 10.8 (24) per phase 15.7 (27) per phase Running Current - Heating Nom (Max) A 9.5 (17) 13.1 (25) 16.6 (27) 19.5 (28) 4.4 (15) per phase 5.6 (15) per phase 6.6 (15) per phase 10.2 (24) per phase 14.4 (27) per phase Power Input - Cooling Nom kw Power Input - Heating Nom kw Start Current A per phase 5 per phase 5 per phase 5 per phase 5 per phase INSTALLATION/REFRIGERANT Ref. Piping Size o.d ins (mm) Liquid 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) <40m = 3/8 >40m = 1/2" 1/2 Gas 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) <35m = 7/8 >35m = 11/8" 1 1/8" Ref. Max Piping Length m Vertical Height Difference (Max) - Outdoor Unit Above Indoor Unit m Outdoor Unit Below Indoor Unit m Refrigerant Amount Precharged kg For Pipe Length Up To m (15 if 1/2" & 1 1/8") 30 Additional Refrigerant g/m (120 if 1/2" & 1 1/8") 120 FDU Hyper 1-Phase (3ph - p.o.a.) FDU100VD FDU125VD FDU140VD ,228 1,231 RC-E4 RC-E4 RC-E FDC100VNX FDC125VNX FDC140VNX ,087 2,294 2, ,121 3,585 3, to to to (A) 3.63 (A) 3.33 (A) to to to (A) 3.81 (A) 3.72 (A) 350 x 1370 x x 1370 x x 1370 x / / / x x x / / / x 970 x x 970 x x 970 x V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 3 + E 3 + E 3 + E 12.3 (25) 15.3 (29) 18.6 (30) 12.9 (25) 16.3 (29) 19.1 (30) /8 (9.52) 3/8 (9.52) 3/8 (9.52) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) Technical Note: FDU Ducted units require gravity condensate drain. Please refer to MHI Technical Manual regarding drain sizes and requirement for traps. When designing ductwork and filtration, refer to manufacturer's Fan Curves. Installation Accessories - Copper Tube Pipe Supports Condensate Pumps & Hose Cables - please see P42 Accessories Condensing Unit Drain Kit Insulation Wall Brackets Isolators TECHNICAL NOTES Group Control is possible (up to 16 systems) using one RC-E4 Remote Controller. RC-E4 Remote Controller includes internal temperature sensor, which can be used as an alternative to the unit return air sensor. HRP Code 6-Way Adaptor for Timeclock & BMS Elbow & Grometts List Price Remote Control & Receiver Kit Network Adaptor SC-ADN-E Fan control kit for FDU U-FCR Fan control kit for FDU U-FCRA Filter kit FDU

13 FDF Floor Vertical Inverter Systems FDF Hyper Inverter Systems Stylish vertical cabinet type indoor units Integral RC-E4 multi function Controller Small footprint - high capacity up to 14kW cooling Low ambient operation to -15ºC Selling Category -B FDF 1-Phase Systems Controller included with FDF FDF 3-Phase Systems INDOOR UNIT incl. Controller FDF71VD FDF100VD FDF125VD FDF140VD FDF100VD FDF125VD FDF140VD HRP Code LIST Price 1,364 1,438 1,538 1,674 1,438 1,538 1,674 OUTDOOR UNIT FDC71VNX FDC100VN FDC125VN FDC140VN FDC100VS (3 phase) FDC125VS (3 phase) FDC140VS (3 phase) HRP Code LIST Price 1,523 1,784 1,928 2,221 1,784 1,928 2,221 NEW Pipe length up to 100m on Hyper Systems 100, 125, 140 FDF Hyper 1-Phase (3ph - p.o.a.) FDF100VD FDF125VD FDF140VD ,438 1,538 1,674 FDC100VNX FDC125VNX FDC140VNX ,087 2,294 2,643 FDF MULTI SPLIT Systems up to 25kW HRP SYSTEM Code SYSTEM LIST Price 2,887 3,222 3,466 3,895 3,222 3,466 3,895 Cooling (Nominal) kw Cooling Range kw 3.2 to to to to to to to 14.5 UK Cooling Nom kw UK Sensible Cooling Nom kw E.E.R (Energy Label) 3.21 (B) 3.21 (B) 2.84 (C) 2.72 (D) 3.21 (B) 2.84 (C) 2.72 (D) Heating (Nominal) kw Heating Range kw 3.6 to to to to to to to 16.5 C.O.P (Energy Label) 3.62 (B) 3.61 (B) 3.21 (C) 3.01 (D) 3.61 (B) 3.21 (C) 3.01 (D) INDOOR UNIT Exterior Dimensions (H x W x D) mm 1850 x 600 x x 600 x x 600 x x 600 x x 600 x x 600 x x 600 x 320 Net Weight kg Air Volume (L - M - H) m3/s Sound Pressure Level** (L / M / H) db(a) 33 / 35 / / 48 / / 48 / / 48 / / 48 / / 48 / / 48 / 50 OUTDOOR UNIT Exterior Dimensions (H x W x D) mm 750 x 880(+88) x x 970 x x 970 x x 970 x x 970 x x 970 x x 970 x 370 Net Weight kg Sound Pressure Level db(a) ELECTRICAL DATA Power Source Rating MCB A per phase 20 per phase 20 per phase Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E Running Current - Cooling Nom (Max) A tba (17) tba (24 tba (24) tba (24) tba (15) per phase tba (15) per phase tba (15) per phase Running Current - Heating Nom (Max) A tba (15) per phase tba (15) per phase tba (15) per phase Power Input - Cooling Nom kw Power Input - Heating Nom kw Start Current A per phase 5 per phase 5 per phase INSTALLATION/REFRIGERANT Ref. Piping Size o.d ins (mm) Liquid 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) Gas 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) Ref. Max Piping Length m Vertical Height Difference (Max) - Outdoor Unit Above Indoor Unit m Outdoor Unit Below Indoor Unit m Refrigerant Amount Precharged kg For Pipe Length Up To m Additional Refrigerant g/m ,525 3,832 4, to to to (A) 3.21 (B) 3.01 (B) to to to (B) 3.61 (B) 3.41 (B) 1850 x 600 x x 600 x x 600 x / 48 / / 48 / / 48 / x 970 x x 970 x x 970 x V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 3 + E 3 + E 3 + E tba (24) tba (26) tba (26) tba (24) tba (26) tba (26) /8 (9.52) 3/8 (9.52) 3/8 (9.52) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) Installation Accessories - Copper Tube Pipe Supports Condensate Pumps & Hose Cables - please see P42 FDF - only Twin Systems available for FDF - See page 24 Insulation Wall Brackets Isolators TECHNICAL NOTES Group Control is possible (up to 16 systems) using one RC-E4 Remote Controller. RC-E4 Remote Controller includes internal temperature sensor, which can be used as an alternative to the unit return air sensor. Accessories HRP Code List Price 6-Way Adaptor for Timeclock & BMS Remote Control & Receiver Kit Network Adaptor SC-ADN-E New for 2011 FDF Vertical Floor Standing Units up to 14kW Cooling, 16kW Heating

14 FD Inverter Multi Systems FD Hyper Inverter Multi Systems The System Codes and Prices below include Indoor Units, Outdoor Unit, and the required Pipe Kits, and Remote Controller. Wall Mounted SRK-ZJX-S Twin and Triple Systms also include one SC-BIKNE Adaptor for each indoor unit. Pipe length up to 100m on FDC100, 125, 140 VNX and VSX (3ph) Outdoor Unit Standard Inverter Indoor Unit Cassette Compact Ceiling Ducted exc. Wall Floor Cassette Suspended RA Filter Kit (ZJX-S) incl. Standing SC-BIKN-E inc. RC-E4 Model Cooling Range (kw) Heating Range (kw) Ref FDT FDTC FDEN FDUM SRK FDF 4.0 to to ,342 3,364 3,250 2,986 3,494 - FDC100VN TWIN (1 x DIS-WA1) Ph * E.E.R (Energy Label) 3.40 (A) 3.52 (A) 3.21 (B) 3.21 (B) 3.62 (A) - C.O.P (Energy Label) 3.62 (B) 3.64 (B) 3.41 (B) 3.43 (B) 3.92 (A) to to ,642 3,612 3,532 3,252 3,774 FDC125VN 1Ph * FDC140VN 1Ph * FDC140VN 1Ph * TWIN (1 x DIS-WA1) E.E.R (Energy Label) 3.16 (B) 2.34 (F) 2.96 (C) 2.80 (D) 2.94 (C) - C.O.P (Energy Label) 3.78 (A) 3.03 (D) 3.66 (B) 3.10 (D) 3.26 (C) to to ,081-4,049 3,935-5,062 TWIN (1 x DIS-WA1) E.E.R (Energy Label) 3.10 (B) (C) 2.80 (D) (D) C.O.P (Energy Label) 3.49 (B) (B) 3.24 (C) (D) 5.0 to to ,470 4,503 4,332 3,936 4,698 - TRIPLE (1 x DIS-TA1) when the differential of branch pipes is < 3m E.E.R (Energy Label) 3.01 (B) 3.02 (B) 2.87 (C) 2.75 (D) 3.09 (B) - C.O.P (Energy Label) 3.46 (B) 3.54 (B) 3.49 (B) 3.18 (D) 3.95 (B) to to ,227-5,203 5,429-6,090 FDC200VS ** TWIN (1 x DIS-WB1) Ph E.E.R (Energy Label) 3.04 (B) (B) 2.92 (C) C.O.P (Energy Label) 3.72 (A) (A) 3.33 (C) to to ,803-5,755 5, FDC200VS ** TRIPLE (1 x DIS-TB1) when the differential of branch pipes is < 3m Ph E.E.R (Energy Label) 3.08 (B) (B) 2.91 (C) - - C.O.P (Energy Label) 3.66 (B) (A) 3.32 (C) to to ,267 6,311 6, FDC200VS ** QUAD (1 x DIS-WB1 & 2 x DIS-WA1) Ph E.E.R (Energy Label) 3.04 (B) 2.73 (D) 2.69 (D) C.O.P (Energy Label) 3.64 (B) 3.21 (C) 3.09 (D) to to ,868-6,180 6,116-6,593 FDC250VS TWIN (1 x DIS-WB1) Ph E.E.R (Energy Label) 3.01 (B) (D) 2.69 (D) (D) C.O.P (Energy Label) 3.61 (B) (B) 3.35 (C) (D) 10.0 to to ,882 6,822 6, FDC250VS QUAD (1 x DIS-WB1 & 2 x DIS-WA1) Ph E.E.R (Energy Label) 3.02 (B) 3.02 (B) 2.63 (D) C.O.P (Energy Label) 3.64 (B) 3.54 (B) 3.22 (C) * 3ph also available: FDC100VS FDC125VS FDC140VS ** If pipe length > 30m the liquid line must be changed to 1/2" and the additional refrigerant charge is 120g/m System prices include all branch kits & 1 x RC-E4 Wired Controller. Mix-match of indoor units: it is possible to connect cassette and ceiling suspended to the same system - poa 24 Outdoor Unit Hyper Inverter Indoor Unit Cassette Compact Ceiling Ducted exc. Wall Floor Cassette Suspended RA Filter Kit (ZJX-S) incl. Standing SC-BIKN-E inc. RC-E4 Model Cooling Range (kw) Heating Range (kw) Ref FDT FDTC FDEN FDUM SRK FDF 3.2 to to 9.0 3,071 3,071 2, FDC71VNX TWIN (1 x DIS-WA1) Ph E.E.R (Energy Label) 3.84 (A) 3.72 (A) 4.08 (A) C.O.P (Energy Label) 4.02 (A) 3.85 (A) 4.35 (A) to to ,645 3,667 3,553 3,289 3,797 - FDC100VNX 1Ph * FDC125VNX 1Ph * FDC140VNX 1Ph * FDC140VNX 1Ph * TWIN SYSTEMS - PIPE SIZING TWIN (1 x DIS-WA1) E.E.R (Energy Label) 3.40 (A) 3.52 (A) 3.21 (B) 3.21 (B) 3.62 (A) - C.O.P (Energy Label) 3.62 (B) 3.64 (B) 3.41 (B) 3.43 (B) 3.92 (A) to to ,008 3,978 3,898 3,618 4,140 - TWIN (1 x DIS-WA1) E.E.R (Energy Label) 3.16 (B) 2.34 (F) 2.96 (C) 2.80 (D) 2.94 (C) - C.O.P (Energy Label) 3.78 (A) 3.03 (D) 3.66 (B) 3.10 (D) 3.26 (C) to to ,503-4,471 4,357-5,484 TWIN (1 x DIS-WA1) E.E.R (Energy Label) 3.10 (B) (C) 2.80 (D) (C) C.O.P (Energy Label) 3.49 (B) (B) 3.24 (C) (C) 5.0 to to ,892 4,925 4,754 4,358 5,120 - TRIPLE (1 x DIS-TA1) when the differential of branch pipes is < 3m E.E.R (Energy Label) 3.01 (B) 3.02 (B) 2.87 (C) 2.75 (D) 3.09 (B) - C.O.P (Energy Label) 3.46 (B) 3.54 (B) 2.87 (C) 3.18 (D) 3.95 (A) - * 3ph Hyper also available: FDC100VSX FDC125VSX FDC140VSX If IR control is required please order 1 x RCN-KIT3-E ( 161) in place of RC-E4 controller ( 63) SYSTEM PRICES INCLUDE ALL BRANCH KITS & 1 x RC-E4 WIRED CONTROLLER Outdoor Unit Indoor Unit Main Pipes Branch Pipes FDC /8" 5/8" 3/8" 1/2" FDC /8" 5/8" 3/8" 1/2" FDC /8" 5/8" 3/8" 1/2" FDC /8" 5/8" 3/8" 5/8" FDC Liquid <40m =' 3/8" >40m = 1/2" FDC Liquid 1/2" TRIPLE SYSTEMS - PIPE SIZING Gas: <35m = 7/8" >35m = 1 1/8" 3/8" 5/8" Gas <35m = 7/8" >35m = 1 1/8" 3/8" 5/8" Outdoor Unit Indoor Unit Main Pipes Branch Pipes FDC /8" 5/8" 3/8" 1/2" FDC Liquid <40m = 3/8" >40m = 1/2" QUAD SYSTEMS - PIPE SIZING Gas <35m = 7/8" >35m = 1 1/8" 3/8" 5/8" Outdoor Unit Indoor Unit Main Pipes Branch Pipes FDC Liquid 1/2" FDC Liquid 1/2" Gas <35m = 7/8" >35m = 1 1/8" 3/8" 1/2" Gas <35m = 7/8" >35m = 1 1/8" 3/8" 5/8" Mix-match of indoor units: it is possible to connect cassette and ceiling suspended to the same system - poa MULTI SYSTEMS have all indoor units operating in the same mode (cool or heat) at the same time. They are ideal for open plan areas, such as large offices, retail shops and stores, fitness gyms, conference halls. Do not install indoor units in separate rooms. COOLING & HEATING capacities listed are for guidance, and are based on nominal ratings. Please refer to technical data for exact cooling & heating values. 25

15 FD Multi Systems incl Hyper Multi Wiring & addressing Group control 1 PHASE OUTDOOR UNITS 3 PHASE OUTDOOR UNITS SYSTEM 0 OUTDOOR UNIT SYSTEM 1 OUTDOOR UNIT L N L1 L2 L3 N E The indoor units must be isolated locally using contacts with a minimum current rating of 5 amps 1 = LIVE 2/2N = Neutral 3 = Signal NB - 3 is a low voltage signal wire and does not need isolating. All electrical instalations should be completed in accordance to local authority regulations When multi systems are controlled in a group (max 16 indoor units) using a single remote controller, it is necessary to set SW2 so each individual multi system has indoor units with the same address connected to it. eg 0-0-0, 1-1-1, N 3 E 1 2N 3 E 1 2N 3 E 1 2N 3 E Master Slave 1 Slave 2 Slave 3 Master SW2=0 Slave SW2=0 Slave SW2=0 Master SW2=1 Slave SW2=1 Slave SW2=1 X Y X Y X Y X Y X Y Indoor board address switches Master Slave 1 Slave 2 Slave 3 SW5-1 OFF OFF ON ON SW5-2 OFF ON OFF ON The Master/Slave address must be set SW5 as above Remote Controller RC-E4 Remote Controller RC-E

16 VRF heat pump (2-pipe) outdoor units KX6 Employs DC inverter compressors only High energy efficiency (high C.O.P) cooling or heating for open plan areas MINI KX6 OUTDOOR UNITS 2-pipe Model 1ph Nominal Capacity (kw) Cooling Heating No. Of Units Connectable Connectable Capacity Power Source Rating D-Curve MCB 230V/50Hz/1ph Running Current Start Current Start Current (per phase) Power Input (kw) Cooling Heating Power Input (kw) Cooling Heating Dimensions H x W x D (mm) Dimensions H x W x D (mm) Weight (kg) Weight (kg) Sound Pressure Level (dba) FDC112KXEN to A 13.0A 5A x 970 x ,525 FDC140KXEN to A 20.6A 5A x 970 x ,778 FDC155KXEN to A 22.3A 5A x 970 x ,163 Model 3ph Nominal Capacity (kw) Cooling Heating Operating Range (Outdoor Air), Cooling -15ºC DB to 43ºC, Heating -20ºC WB to 15.5ºC WB No. Of Units Connectable Connectable Capacity Power Source Rating D-Curve MCB 415V/50Hz/3ph (TPNE) Running Current (per phase) Sound Pressure Level (dba) FDC112KXES to A 4.3A 5A x 970 x ,525 FDC140KXES to A 6.6A 5A x 970 x ,778 FDC155KXES to A 7.1A 5A x 970 x ,163 Factory Ref Charge (kg) Factory Ref Charge (kg) HRP CODE HRP CODE List Price List Price COMPACT KX6 OUTDOOR UNITS 2-pipe Model Nominal Capacity (kw) Cooling Heating Operating Range (Outdoor Air), Cooling -15ºC DB to 43ºC, Heating -20ºC WB to 15.5ºC WB No. Of Units Connectable Connectable Capacity Power Source Rating D-Curve MCB 415V/50Hz/3ph (TPNE) Running Current (per phase) Start Current (per phase) Power Input (kw) Cooling Heating Dimensions H x W x D (mm) Weight (kg) Sound Pressure Level (dba) FDC224KXE6* to A 9.0A 5A x 1080 x ,609 FDC280KXE6* to A 12.3A 5A x 1080 x ,311 FDC335KXE6* to A 15.0A 5A x 1080 x ,740 Factory Ref Charge (kg) HRP CODE List Price VERTICAL KX6 OUTDOOR UNITS 2-pipe Model Nominal Capacity (kw) Cooling Heating No. Of Units Connectable Connectable Capacity Power Source Rating D-Curve MCB 415V/50Hz/3ph (TPNE) Running Current (per phase) Start Current (per phase) Power Input (kw) Cooling Heating Dimensions H x W x D (mm) FDC400KXE6* to x 25A 17.9A 8A x 1350 x ,180 FDC450KXE6* to x 32A 19.9A 8A x 1350 x ,466 FDC504KXE6* to x 32A 23.1A 8A x 1350 x ,519 FDC560KXE6* to x 40A 25.7A 8A x 1350 x ,060 FDC615KXE6* to x 40A 30.3A 8A x 1350 x ,267 FDC680KXE6* to x 50A 36.9A 8A x 1350 x ,807 (FDC335KXE6-K + FDC400KXE6) FDC735KXE6* to x 25A 31.4A 16A x 2700 x x x 2-19,619 (FDC400KXE6 + FDC400KXE6) FDC800KXE6* to x 25A 35.8A 16A x 2700 x x x 2-20,360 (FDC400KXE6 + FDC450KXE6) FDC850KXE6* to x 25A 1 x 32A 37.8A 16A x 2700 x x x 2-22,646 (FDC450KXE6 + FDC450KXE6) FDC900KXE6* to x 32A 39.8A 16A x 2700 x x x 2-24,932 (FDC450KXE6 + FDC504KXE6) FDC960KXE6* to x 32A 43.0A 16A x 2700 x x 2-25,985 (FDC504KXE6 + FDC504KXE6) FDC1010KXE to x 32A 46.2A 16A x 2700 x x x 2-27,038 (FDC504KXE6 + FDC560KXE6) FDC1065KXE to x 32A 1 x 40A 48.8A 16A x 2700 x x x 2-27,579 (FDC560KXE6 + FDC560KXE6) FDC1130KXE to x 40A 51.4A 16A x 2700 x x x 2-28,120 (FDC560KXE6-K + FDC615KXE6) FDC1180KXE to x 40A 55.4A 16A x 2700 x x 2-30,872 (FDC615KXE6 + FDC615KXE6) FDC1235KXE to x 40A 60.6A 16A x 2700 x x x 2-32,534 (FDC615KXE6 + FDC680KXE6) FDC1300KXE to x 40A 1 x 50A 67.2A 16A x 2700 x x 2-33,074 (FDC680KXE6 + FDC680KXE6) FDC1360KXE to x 50A 73.8A 16A x 2700 x x x 2-33,614 Weight (kg) Sound Pressure Level (dba) Factory Ref Charge (kg) HRP CODE List Price Operating Range (Outdoor Air), Cooling -15ºC DB to 43ºC, Heating -20ºC WB to 15.5ºC WB * When connecting the indoor unit types FDK, FDFL, FDFU or FDFW, the Connectable Capacity is limited to no higher than 130%

17 VRF heat recovery (3-pipe) outdoor units KXR6 Employs DC inverter compressors only High efficiency heat recovery allows simultaneous heating and cooling KXR OUTDOOR UNITS 3-pipe Model Nominal Capacity (kw) Cooling Heating No. Of Units Connectable Connectable Capacity Power Source Rating D-Curve MCB 415V/50Hz/3ph (TPNE) Running Current (per phase) Start Current (per phase) Power Input (kw) Cooling Heating Dimensions H x W x D (mm) FDC224KXRE6* to x 16A 9.2A 5A x 1350 x ,648 FDC280KXRE6* to x 20A 13.5A 5A x 1350 x ,323 FDC335KXRE6* to x 25A 15.9A 5A x 1350 x ,010 FDC400KXRE6* to x 25A 19.9A 8A x 1350 x ,698 FDC450KXRE6* to x 32A 22.0A 8A x 1350 x ,060 FDC504KXRE6* to x 32A 25.2A 8A x 1350 x ,465 FDC560KXRE6* to x 40A 28.4A 8A x 1350 x ,006 FDC615KXRE6* to x 50A 34.7A 8A x 1350 x ,710 FDC680KXRE6* to x 63A 44.9A 8A x 1350 x ,251 (FDC335KXRE6-K + FDC400KXRE6) FDC735KXRE6* to x 25A 35.4A 16A x 2700 x x ,509 (FDC400KXRE6 + FDC400KXRE6) FDC800KXRE6* to x 25A 39.8A 16A x 2700 x x ,396 (FDC400KXRE6 + FDC450KXRE6) FDC850KXRE6* to x 25A 1 x 32A 41.9A 16A x 2700 x x ,758 (FDC450KXRE6 + FDC450KXRE6) FDC900KXRE6* to x 32A 44.0A 16A x 2700 x x ,120 (FDC450KXRE6 + FDC504KXRE6) FDC960KXRE6* to x 32A 47.2A 16A x 2700 x ,525 (FDC504KXRE6 + FDC504KXRE6) FDC1010KXRE to x 32A 50.4A 16A x 2700 x x ,930 (FDC504KXRE6 + FDC560KXRE6) FDC1065KXRE to x 32A 1 x 40A 53.2A 16A x 2700 x x ,471 (FDC560KXRE6 + FDC560KXRE6) FDC1130KXRE to x 40A 56.8A 16A x 2700 x x ,012 (FDC560KXE6-K + FDC615KXE6) FDC1180KXRE to x 40A 1 x 50A 63.1A 16A x 2700 x ,990 (FDC615KXRE6 + FDC615KXRE6) FDC1235KXRE to x 50A 69.4A 16A x 2700 x x ,420 (FDC615KXRE6 + FDC680KXRE6) FDC1300KXRE to x 50A 1 x 63A 79.6A 16A x 2700 x x ,961 (FDC680KXRE6 + FDC680KXRE6) FDC1360KXRE to x 63A 89.8A 16A x 2700 x x ,502 Operating Range (Outdoor Air), Cooling -15ºC DB to 43ºC, Heating -20ºC WB to 15.5ºC WB * When connecting the indoor unit types FDK, FDFL, FDFU or FDFW, the Connectable Capacity is limited to no higher than 130%. Weight (kg) Sound Pressure Level (dba) Factory Ref Charge (kg) HRP CODE List Price KX Branch pipes KX/KXR Branch pipes & Branch Controllers MINI KX6 (2-PIPE HEAT PUMP) BRANCH PIPES & HEADERS Type Model Description HRP CODE List Price Branch Pipe Kit DIS-22-1 Downsteam capacity less than Branch Pipe Kit DIS Downsteam capacity of 180 to Header (4 Branch) HEAD Downsteam capacity less than Header (6 Branch) HEAD Downsteam capacity of 180 to KX6 (2-PIPE HEAT PUMP) BRANCH PIPES & HEADERS Type Model Description HRP CODE List Price Branch Pipe Kit DIS-22-1 Downsteam capacity less than Branch Pipe Kit DIS Downsteam capacity of 180 to Branch Pipe Kit DIS Downsteam capacity of 371 to Branch Pipe Kit DIS Downsteam capacity of 540 or more Header (4 Branch) HEAD Downsteam capacity less than Header (6 Branch) HEAD Downsteam capacity of 180 to Header (8 Branch) HEAD Downsteam capacity of 371 to Header (8 Branch) HEAD Downsteam capacity of 540 or more Outdoor Unit Manifold DOS-2A-1 For combined outdoor units KXR6 (3-PIPE HEAT RECOVERY) PFD CONTROLLERS, BRANCH PIPES & HEADERS Type Model Description HRP CODE List Price Branch Controller PFD1123-E Downsteam capacity less than 112 (connectable no. of units 1-5) Branch Controller PFD1803-E Downsteam capacity of 112 to 179 (connectable no. of units 1-8) Branch Controller PFD2803-E Downsteam capacity of 180 to 279 (connectable no. of units 1-10) Branch Controller (4-Way) PFD1123X4-E Downsteam capacity less than 112 per branch (1-5 units) with a total capacity less than 371 (max. 16 units) ,705 Extension Cable PFD-15WR-E 15m extension cable for PFD controller POA Branch Pipe Kit DIS-22-1-R For units before PFD Controller - downsteam capacity less than Branch Pipe Kit DIS R For units before PFD Controller - downsteam capacity of 180 to Branch Pipe Kit DIS R For units before PFD Controller - downsteam capacity of 371 to Branch Pipe Kit DIS R For units before PFD Controller - downsteam capacity of 540 or more Branch Pipe Kit DIS-22-1 For units after PFD Controller - downsteam capacity less than Branch Pipe Kit DIS For units after PFD Controller - downsteam capacity of 180 to Branch Pipe Kit DIS For units after PFD Controller - downsteam capacity of 371 to Branch Pipe Kit DIS For units after PFD Controller - downsteam capacity of 540 or more Outdoor Unit Manifold DOS-2A-1-R For combined outdoor units These can be used with KXR4 & KXR6 Outdoor Units but with only KXE6 Indoor Units

18 VRF Indoor units FDT FDTC FDTQ FDUT FDUH FDUM FDU FDE FDK FDFW FDFU Type Model Nominal Capacity (kw) Cooling Heating Power Supply 230V/50Hz/1ph Dimensions H x W x D (mm) Weight (kg) Air Volume (m3/s) Sound Pressure Level (dba) FDT: 4-Way Cassette FDT28KXE6D A 246 x 840 x / 31 / FDT36KXE6D A 246 x 840 x / 31 / FDT45KXE6D A 246 x 840 x / 31 / ,004 FDT56KXE6D A 246 x 840 x / 31 / ,075 FDT71KXE6D A 246 x 840 x / 31 / ,133 FDT90KXE6D A 298 x 840 x / 37 / ,261 FDT112KXE6D A 298 x 840 x / 37 / ,436 FDT140KXE6D A 298 x 840 x / 40 / ,627 FDT160KXE6D A 298 x 840 x / 41 / ,678 Fascia Panel T-PSA-3AW-E x 950 x FDTC: Cassette (600x600) FDTC22KXE6D A 248 x 570 x / 33 / FDTC28KXE6D A 248 x 570 x / 33 / FDTC36KXE6D A 248 x 570 x / 36 / FDTC45KXE6D A 248 x 570 x / 37 / FDTC56KXE6D A 248 x 570 x / 39 / ,023 Fascia Panel TC-PSA-25W-E x 700 x FDTQ: 1-Way Cassette FDTQ22KXE6D A 250 x 570 x / (600x600) FDTQ28KXE6D A 250 x 570 x / FDTQ36KXE6D A 250 x 570 x / Fascia Panel TQ-PSA-15W-E x 625 x FDUT: Ultra Slim Ducted FDUT22KXE6D A 220 x 750 x / 26 / FDUT Filter Kits - see below FDUT28KXE6D A 220 x 750 x / 26 / FDUT36KXE6D A 220 x 750 x / 31 / FDUT45KXE6D A 220 x 950 x / 32 / FDUT56KXE6D A 220 x 950 x / 34 / Filter Kit FDUT FDUT type UT-FL1E Filter Kit FDUT FDUT type UT-FL2E FDUH: Compact Ducted FDUH22KXE6D A 257 x 570 x / 30 / (control box & drain piping FDUH28KXE6D A 257 x 570 x / 30 / can be left or right handed) FDUH36KXE6D A 257 x 570 x / 30 / Filter Kit FDUH FDUH all models type UH-FL1E FDUM: Ducted FDUM22KXE6D A 299 x 750 x / 31 / FDUM28KXE6D A 299 x 750 x / 31 / FDUM36KXE6D A 299 x 750 x / 31 / FDUM45KXE6D A 299 x 750 x / 32 / ,008 FDUM56KXE6D A 299 x 750 x / 32 / ,048 FDUM71KXE6D A 299 x 950 x / 32 / ,112 FDUM90KXE6D A 299 x 950 x / 33 / ,276 FDUM112KXE6D A 350 x 1370 x / 35 / ,568 FDUM140KXE6D A 350 x 1370 x / 36 / ,672 Filter Kit FDUM FDUM 22-56HKXE6 type UM-FL1E Filter Kit FDUM FDUM HKXE6 type UM-FL2E Filter Kit FDUM FDUM HKXE6 type UM-FL3E HRP CODE List Price Type Model Nominal Capacity (kw) Cooling Heating FDU: High-Static Ducted FDU71KXE6D A 297 x 850 x / ,189 FDU90KXE6D A 350 x 1370 x / ,352 FDU112KXE6D A 350 x 1370 x / ,659 FDU140KXE6D A 350 x 1370 x / ,749 FDU224KXE6D A 360 x 1570 x ,591 FDU280KXE6D A 360 x 1570 x ,573 FDE: Ceiling Suspended FDE36KXE6D A 210 x 1070 x / 38 / ,259 FDE45KXE6D A 210 x 1070 x / 38 / ,304 FDE56KXE6D A 210 x 1070 x / 38 / ,337 FDE71KXE6D A 210 x 1320 x / 39 / ,427 FDE112KXE6D A 250 x 1620 x / 41 / ,482 FDE140KXE6D A 250 x 1620 x / 44 / ,727 FDK: High Wall FDK22KXE6D A 298 x 840 x / 33 / FDK28KXE6D A 298 x 840 x / 33 / FDK36KXE6D A 298 x 840 x / 35 / FDK45KXE6D A 298 x 840 x / 37 / FDK56KXE6D A 298 x 840 x / 42 / FDK71KXE6D A 318 x 1098 x / 43 / FDFW/FDFL: Floor Mounted FDFW28KXE6D A 600 x 860 x / 34 / (With Casing) FDFW45KXE6D A 600 x 860 x / 36 / FDFW56KXE6D A 600 x 860 x / 37 / FDFL71KXE6D A 630 x 1481 x / 41 / ,398 FDFU: Floor Mounted FDFU28KXE6D A 630 x 1077 x / 38 / ,244 Concealed Type FDFU45KXE6D A 630 x 1077 x / 41 / ,256 (Without Casing) FDFU56KXE6D A 630 x 1077 x / 41 / ,278 FDFU71KXE6D A 630 x 1362 x / 41 / ,312 SAF Heat Exchange Ventilation Units & DX Kits Power Supply 230V/50Hz/1ph Dimensions Weight H x W x D (mm) (kg) Air Volume (m3/s) Sound Pressure Level (dba) SAF: Fresh Air Ventilation SAF250E A 270 x 882 x / ,181 And Heat Exchange Unit SAF350E A 270 x 882 x / ,357 SAF500E A 270 x 962 x / ,537 SAF800E A 388 x 1322 x / ,364 SAF1000E A 388 x1322 x / ,614 SAF-DX250KXE6 DX kit for SAF ,784 SAF-DX350KXE6 DX kit for SAF ,004 SAF-DX500KXE6 DX kit for SAF ,222 SAF-DX800KXE6 DX kit for SAF ,464 SAF-DX1000KXE6 DX kit for SAF ,684 HRP CODE List Price 32 33

19 Valve Kits Controls and accessories EEV-KIT is a control kit for operating a locally provided AHU and/or fan coil units with direct expansion (DX) heat exchanger interlaced coils combined with the KX6 VRF Range. SINGLE REFRIGERATION SYSTEM FAN AHU EEV-Control Assembly EEV-Control Box Sensor (5pcs) Thi-A Thi-R2 Thi-AF Thi-R1 Thi-R3 There are 3 types of EEV Valve Assemblies EEV - KIT + Strainer MULTI REFRIGERATION SYSTEM FAN AHU EEV-Valve Assembly EEV valve, body EEV coil Strainer AVAILABLE SUMMER 2011 EEV-Kit (air handling unit interface) The diagram represents a 4-circuit interlaced heat exchanger The EEV-Kit is made up of the EEV Control Assembly and the EEV-Valve Assembly (coil and strainers). Please note the the Control Assembly is not waterproof and must be housed in a weatherproof enclosure. RCH-E3 (wired) RC-E4 (wired) SC-SL2N-E SC-SL3N-AE/BE S Model Description HRP CODE CONTROLS RC-E4 Wired remote controller (2 wire) - new PAC & KX RCH-E3 Simplified wired remote controller (2 wire) - new PAC & KX SC-ADNA-E Super Link adapter PJA504A178XR 6-Way Adaptor to CnT port for run, fault, on/off, heat, & compressor run SC-THB-E3 Remote Sensor SC-BIKN-E Interface for use of wired remote controller (RC-E4) - SRK & SRF-ZJX-S indoor units RCN-E-E Infra-red remote control kit FDE (ceiling suspended) RCN-K-E Wireless RC for FDK RCN-K71-E Wireless RC for FDK RCN-FW-E Wireless RC for FDFW RCN-T36W-E Infra-red remote control kit for FDT (cassette) RCN-TC-24W-E Infra-red remote control kit for FDTC-VB (compact cassette) RCND-KIT3-E Infra-red remote control kit for FDUM & FDU (ducted) CENTRAL CONTROLS AND BMS GATEWAYS SC-SL1N-E Centralised controller (on/off of up to 16 indoor units) SC-SL2NA-E Centralised controller (on/off & weekly timer function of up to 64 indoor units) SC-SL3NA-AE Touch panel centralised controller (multi-function of up to 128 indoor units) ,823 SC-SL3NA-BE Touch panel centralised controller (multi-function of up to 128 indoor units+electricity usage calculation) ,097 SC-WGWNA-A Web gateway (for PC Windows central control via Internet Explorer) ,255 SC-LGWNA-A LONworks gateway ,320 SC-BGWNA-A BACnet gateway ,320 SLB-3BX Backbox for SC-SL3N touch panel centralised controller FD-MULTI SYSTEMS BRANCH PIPES DIS-WA1 Twin branch pipe kit FDC DIS-WB1 Twin branch pipe kit FDC DIS-TA1 Triple branch pipe kit - FDC DIS-TB1 Triple branch pipe kit - FDC FILTER KITS FOR DUCTED UNITS UH-FL1E Filter for FDUH UT-FL1E Filter for FDUT UT-FL2E Filter for FDUT U-FCR FAN Control kit for FDU U-FCRA FAN Control kit for FDU List Price Type EEV6-71-E EEV6-160-E EEV6-280-E Capacity kw kW kW kW Part Number Description HRP CODE List Price EEVKIT6-E-M Master Control Assembly ,636 EEVKIT6-E-C Slave Control Assembly ,636 EEV6-71-E Valve Assembly kW (per DX coil) EEV6-160-E Valve Assembly kW (per DX coil) EEV6-280-E Valve Assembly kW (per DX coil) Air Handling Unit Valve Kit for FD Inverter Split Systems Valve Kits allow air handling units to be connected to high performance FD-Series split system outdoor units - from 7kW to 25kW. The installer is responsible for the design of the air handler and coil(s). The Valve Kit is suitable for control using Wired Controller RC-E4 (623194) - ordered separately AHU2PAC25 Valve Kit for FD-Series PAC ,183 Please contact 3D or HRP for further information

20 xxxxxxxxxxxxxxxxxxxx Air to water Heat Pump Specifications Air to water heat pump is a revolutionary energy recycling system which reduces environmental load by reusing heat energy produced in daily life. This first-rate energy saving system has been developed by our exceptional technology. Our Air to Water Heat Pump is a complete modern system for heating, cooling and producing hot sanitary water for houses, offering effective energy saving and reducing carbon dioxide emission. Our product is safe and economical with integrated hot water heater, immersion heater, circulating pump and climate system within the indoor unit. The heat energy is retrieved from the outdoor air, and is transferred to the indoor unit by the medium of refrigerant circulated in closed piping system. This eliminates the needs of bore holes and coils associated with ground source heat pumps. Features FDCW71VNX FDCW100VNX HMA100V FDCW140VNX HMS140V MT300 HMA100VM Radiator or Fan coil Optimum annual operation costs thanks to the inverter driven compressor. The speed of the compressor is controlled according to the demand, and the industries highest COP level of 4.08~4.44* in heating operation has been achieved. The compact size (600x650mm footprint) has been achieved by integrating the hot water tank for sanitary water together with the water heat exchanger in indoor unit. Electric wiring and piping works are simpler due to integrated indoor unit design. Max temperature flow line is 65ºC with use of a large-capacity auxiliary electric heater as standard equipment for back-up so that the system will be able to cope with irregular and excessive use of hot water. (58ºC with only use of compressor) 36 Floor Heating Refrigerant Water pipe (for Air Conditioning) Water pipe (for Sanitary) Water heat exchanger + Heat storage unit Sanitary Air - water heat circulation system is an excellent energy recycling system. Various sterilization temperature settings according to the requirements of each country. Water supply pressure at showers and faucets to second and third floors will not drop. By utilizing the direct incoming water supply and not using water from a storage tank water pressure and quality is maintained as well as the reduction in risk of legionella bacteria generation. It is recommended that installers/engineers attend the MHI Air to Water Training Course Module 20 Selling Category - W System Heating Output Indoor Model HRP Code List Price * Outdoor Model HRP Code List Price * Tank Size (L) SYSTEM LIST PRICE * 7.1kW ( kW) 3.0HP HMA100V ,550 FDCW71VNX , , kW ( kW) 3.5HP HMA100V ,550 FDCW100VNX , , kW ( kW) 6.0HP HMS140HT ,865 FDCW140VNX , , kW ( kW) 6.0HP HMS140MT ,680 FDCW140VNX , , kW ( kW) 6.0HP HMS140MT ,135 FDCW140VNX , ,485 * The above list prices are subject to the 3D/HRP air to water discount structure. The heating outputs are at 7ºC DB (6ºC WB) with a water temperature of 45ºC out / 40ºC in. 3HP 3.5HP 6HP Indoor Model HMA100V HMA100VM HMA100V HMA100VM HMS140V Outdoor Model FDCW71VNX FDCW100VNX FDCW140VNX Power source 1 phase 230V 50Hz 1 phase 230V 50Hz 1 phase 230V 50Hz 3 phase 400V 50Hz 3 phase 400V 50Hz 3 phase 400V 50Hz Heating condition 1 kw 8.0 ( ) 9.0 ( ) 16.5 ( ) Nominal capacity condition 2 kw 8.3 ( ) 9.2 ( ) 16.5 ( ) COP condition condition Cooling condition 1 kw 7.1 ( ) 8.0 ( ) - Nominal capacity condition 2 kw 10.7 ( ) 11.0 ( ) 16.5 ( ) EER condition condition Tapping capacity 12liter/min litre liter/min litre Operation range heating * (Ambient temperature) Cooling Operation range heating (65 with immersion heater) (Water temperature) cooling Max refrigerant pipe length m Max height difference between IU and OU m 7 Indoor Unit Height mm 1760 (+20-50mm, adjustable feet) 1004 Width mm Depth mm Weight (without water in the system) Kg Immersion heater 9kW 4steps (1/phase or 3/phase) - Volume total litre % - Volume hot water coil litre 14 - Volume expansion vessel litre - 18 Dimensions, climate system pipe mm Dimensions, hot water pipe mm Water pipe connections Compression fittings Outdoor Unit Height mm Width mm 780 (+67 with value cover) Depth mm (+80 with foot rail) 370 (+80 with foot rail) Weight Kg Sound Power level*2 db(a) Sound Pressure level*2 db(a) Airflow m3/min Type of compressor Rotary Ref control EEV Refrigerant volume (pipe length without additional charge) Kg 2.55 (15) 2.19 (12) 4.0 (15) Dimensions, refrigerant pipe mm(inches) Gas pipe: OD (5/8 ), Liquid pipe: OD 9.52 (3/8 ) Ref pipe connections Flare MHI Water Tanks (for HMS140V hydro indoor unit only) are available in 30 litre, 300 litre and 500 litre capacities. Please contact 3D/HRP for further technical information. If a third party water storage tank is used there will be a reduction of water pressure at showers and faucets when they are used at the same time. 37

21 Error Codes Error Codes Remote Control Error Code Location of Issue - Indoor Unit Power - Remote Controller Wires Description of Issue Power Off; Broken wire loom, fuse Broken transformer wire Poor connection, break in controller wire *For wire breaking at power ON, the LED is off - Remote Controller *Defective Remote Controller PCB Wait or Stays Off Indoor-Outdoor units connection wire *Poor connection, break of indoor-outdoor unit connection wire Wait or Stays Off Remote Control Improper setting of master and slave by r/c Poor connection of R/C signal wire (white) E1 R/C Wires (Noise) *For wire break at power on the LED is off Intrusion of noise in r/c wire *Defective R/C or indoor control unit PCB (defective communication circuit) E3 Outdoor signal line Indoor unit power failure control wiring open circuit or incorrectly wired E5 E6 E7 E8 E9 Indoor-outdoor units connection wire Communication cable (noise) Indoor hx thermistor Indoor Unit return air sensor Install or Operating condition Indoor HX thermistor Drain Trouble Float Switch Poor connection of wire between in/outdoor during operation (disconnect/loose connection) CPU-runaway on outdoor unit control PCB Defective indoor units HX temperature sensor (broken thermistor, short circuit) Poor contact of temperature thermistor connector Defective indoor unit return air sensor (broken/short circuit) or Poor contact of temperature sensor connector Heating Overload (High Indoor HX temperature) Defective indoor unit HX thermistor (short circuit) Defective drain pump (DM), broken drain pump wire, disconnected connector Abnormal float switch operation (malfunction) E10 Excessive No. of Connected Indoors (more than 16) When Multi-Unit control by R/C is performed, the number of IU is over 16 E12 Address setting error Improper addressing of indoor unit E14 E16 Master/slave Indoor unit address No. Setting Communication error between master and slave indoor units Fan Motor Blown Fan Motor Fuse Improper master and slave address setting Abnormal r/c wire connection, broken between master and slave units Defective fan motor (FDT) Defective indoor unit control PCB E19 Indoor unit control PCB Improper operation mode setting of drain motor E28 R/C temperature thermistor R/C temperature thermistor connector Broken wire of R/C temperature Thermistor Faulty connection of R/C temperature Thermistor E30 Unmatched connection of indoor/outdoor unit Faulty signal wiring or open circuit Indoor / outdoor unit PCB fault Improper addressing of outdoor unit E31 Duplicated outdoor unit address No. More than 128 indoor units No setting or master/slave on combination outdoor E32 Open L3 Phase on power supply Faulty power supply and L3 primary side E33 Power Supply Wires Abnormal current on inverter primary side E35 Installation, Op. Status Higher Outdoor unit HX temperature OU HX temperature Thermistor Defective OU HX temperature Thermistor Remote Control Error Code Location of Issue Description of Issue E35 OU Control PCB Defective OU control PCB (defective temp sensor input circuit) E36 E37 E38 E39 E40 E41 E43 E42 E45 E46 E47 E48 E49 Discharge pipe temperature error Outdoor heat exchanger temperature anomaly Ambient air temperature thermistor anomaly Discharge pipe temperature thermistor anomaly High pressure error (63H1 activated) Power transistor overheat Excessive number of indoor units or capacity of connection Current Cut Inverter communication error Mixed address settings on same network Inverter over-current error DC outdoor fan motor error Low pressure error Low pressure sensor anomaly Defective discharge pipe temperature thermistor Clogged filter / short circuit of outdoor units Broken outdoor heat exchanger thermistor Disconnected / defective thermistor connector Broken air temperature thermistor Disconnected / defective thermistor connector Broken discharge pipe thermistor Disconnected / defective thermistor connector Short cicuit of air flow / breakdown of fan motor Defective 63H1 connector, Closed service valve Defective outdoor unit fan motor Improperly fixed power transistor radiator fin Defective power transistor temperature thermistor Too many indoor units connected, exceeds capacity Improper indoor/outdoor unit address setting Faulty power supply, power transistor, compressor Service valves closed, insufficient refrigerant Defective connector between PCB and inverter PCB Defective Inverter PCB Old superlink (KX4)/ New superlink (KX6) mixed on the same network Dust on Control PCB, defective outdoor control PCB Blown F3 fuse Dust on Control PCB, defective outdoor control PCB Defective fan motor, Blown F3 fuse Detective suction pipe temperature thermistor/connector Defective low pressure sensor or sensor connection E51 Inverter fan motor anomaly Defective fan motor or Inverter control PCB E53 E54 E55 Suction pipe temperature thermistor anomaly Low pressure sensor anomaly Underneath temperature thermistor anomaly Defective suction pipe temperature thermistor Defective suction pipe temperature thermistor connector Defective low pressure sensor or connection Improper amount of refrigerant Defective underneath temperature thermistor Defective underneath temperature thermistor connector E56 Power transister temperature sensor anomaly Insufficient time passed after crankcase heater on faulty compressor E57 Insufficient refrigerant amount Service valve closure Insufficient refrigerant amount / closed valves Defective indoor R/A temperature thermistor or connector E58 Anomalous Compressor by loss of synchronism Compressor started without crack case heater on Faulty fan motor, improper refrigerant amount E59 Compressor startup failure Abnormal power supply or faulty compressor Defective outdoor fan motor or inverter PCB E60 Compressor rotor lock Improper refrigerant amount Abnormal power supply or faulty compressor E63 Emergency stop On signal submitted on CnT terminal of indoor unit

22 MHI Training Technical Centre AIR CONDITIONING & HEAT PUMP TECHNOLOGY Sponsored by MITSUBISHI HEAVY INDUSTRIES Training for Engineers Technical training has provided a huge benefit for installers, service engineers and controls technicians over the last few years. MHI split systems and VRF systems are constantly being developed, with improved specifications and performance, so a comprehensive understanding of installation procedures, commissioning, and troubleshooting, allows engineers to be fully competent and cost effective when applying their skills. MHI Training Module 1 Introduction to MHI Equipment Module 2 RAC (Splits) & PAC (Multi-Splits) Module 3 KX VRF Application & Selection Module 4 KX VRF Operation, Installation & Service Module 7 SLA & SLB Control Systems & Operation Module 8 Installing MHI R410A onto existing lines Module 9 Mente PC KX & KXR System Monitoring Module 10 Commissioning KX & KXR NEW Module 11 Installation & Troubleshooting Split Systems Module 12 Intensive Troubleshooting & Diagnostics (3 hour) C&G2079 F-Gas Courses Including Assessment The deadline for engineers is 4th July After this date it will be illegal to work on systems containing refrigerant. The courses, including Assessment and Certification, are undertaken at many of the HRP Service Centres, providing both a consistent and localised availablility. All course bookings, allocation of spaces, cancellations, etc, are subject to HRP Ltd Terms and Conditions. C&G2079 Course Content Analysing system performance to determine efficiency by utilising pressure, temperature state of Refrigerant, etc. How to carry out an adequate leak test, using both direct and indirect methods Understanding theoretical operation of a refrigeration/air conditioning system Brazing and Jointing skills Identifying Refrigerants Charging and recovering a zeotropic refrigerant How to pressure test and evacuate in compliance with BS-EN Completing the required records to comply with F-Gas Regulations Disposing of all created hazardous waste in the correct legal manner The MHI Technical Centre at Slough has working systems, including VRF with fully integrated controls, BMS Gateways, and Centralized Controllers. New MHI Training Modules We have recently introduced intensive practical training for engineers who are already familiar with MHI and other equipment, and who are interested in extending their knowledge and getting updated on the latest developments and control/diagnostic technology. Two new courses Modules 11 & 12 are now running, and are proving extremely popular. These hands-on sessions are based specially designed rigs, and are held at HRP Service Centres throughout the country. 3-day and 5-day Courses 3-day Courses are available for the candidate who already has good knowledge of refrigeration processes, including the associated theory, with 5-day courses for those who may have been out of training for some time, and require more in-depth support on theoretical knowledge. If you are unsure which course is right for you, please complete our online Skill Scan, and one of our trainers will review the best option available. Please note: the Courses include a practical exam, and GOLA exam on C&G2079 For full details please call: or visit: Training rig photos - Walthamstow service centre 40 41

23 Installation Accessories from HRP xxxxxxxxxxxxxxxxxxxx Copper Tube Coils Refrigeration quality soft copper All sizes suitable for R410A Tube OD 15 metres 30 metres Sell Category C 1/4" poa poa 3/8" poa poa 1/2" poa poa 5/8" poa poa 3/4" poa poa 7/8" poa n/a poa For today's copper prices look on the HRP website contact your Service Centre for access password Isoline Insulation Class "0" Isoline Insulation Class "0" Closed Cell 15 metre lengths (internally talced) Sell Category M Closed Cell 2 metre lengths Tube 1/4" List 3/8" List 1/2" List OD wall price wall price wall price 1/4" /8" /2" /8" /4" /8" Other sizes available on request Sell Category M Tube OD 3/8" wall List price 1/2" wall List price 1/4" /8" /2" /8" /4" /8" Other prices available on request Sell Category E Insulclamp Professional pipe support systems. Use with Unistrut Channel. Insulclamp supplied individually or in bags of 10 Tube OD Code List price 1/4" /8" /2" /8" /4" /8" Sell Category E Grip Locks Designed for liquid and gas pipes, including insulation, with space for electrical cables and condensate tube box quantity 10 Tube OD Code List price (10) 1/4 & 1/ /8 & 5/ /2 & 7/ /8 & 1 1/ Also available: Squeezy Fit Clamps Pipe Hangers. Quick Positioning Clips Studding Clips. Pipe Saddles Nuts Bolts Washers Sell Category G Unistrut Channel Galvanised Steel Channel 3 metre lengths Code List price 41 x 21 plain x 41 plain x 21 slotted x 41 slotted Unistrut Cantilever brackets also available Sell Category L Condensing Unit Brackets Brackets are finished in ivory powder coat paint and supplied with fixings to mount unit (excl. rawl bolts) Code List price Type kg (max) Type kg (max) Type kg (max) Type kg (max) Wall Fixing Bolts Code Sell Category G List price Rawl Bolts M Projection Bolts M Sell Category F Unistrut type Cantilever brackets (pair) Including 750mm vertical rails, 600mm cantilever arms, end caps, unit fixing bolts, and rawl bolts Code List price Ready to Go Kit 600mm Condensate Trays and Security Cages are also available Tools & Equipment A huge variety of service tools, hand tools, and other equipment are available from 17 Service Centres throughout the UK. These include: Gauges & Manifolds Electronic Manifolds Vacuum Pumps Charging Scales Recovery Equipment Multimeters Inverter Checkers Pipe Benders Tube Expanders Tube Cutters Flaring Tools Hand Tools For Trade Discounts contact your local Service Centre, or log on to 42 43

24 Condensate Pumps Cables & Electrical Sell Category C Peristaltic Type (non-tank) Make Model Max Head m Code List price Aspen Standard 12 / Aspen Universal 12 / Little Giant PCT / Sell Category N Sauermann Standard 12 / Sauermann Universal 12 / Sell category E Hi-Tuff 100 metres Black Code List price 3 core 1.5mm core 1.5mm core 1.5mm core 2.5mm core 2.5mm Sell Category C Tank Type Make Model Max Head m Code List price Aspen Hi-Lift Aspen Hi-Lift Aspen Hi-Flow Aspen Hi-Flow Aspen MiniBlanc Little Giant VCMA Little Giant VCC20S Little Giant VCMA20S Little Giant VCMX20S Pump House PH0.2L Pump House PH0.5L Pump House PH2L Sell category E SY Braided Sheath 100 metres Clear PVC Sheath Code List price 3 core 1.5mm core 1.5mm core 1.5mm core 2.5mm core 2.5mm Sell category E LI YCY Screened Multicore Suitable for Remote Control Wiring Code List price 2 core screened 0.75mm core screened 0.75mm core screened 0.75mm core screened 0.75mm Sell Category C Split/Remote Sensor Type Make Model Max Head m Code List price Aspen* FP Aspen* FP Little Giant EC Pump House* DE-05-FD Sell Category N Sauermann SI * Fits into 90 trunking elbow Sell Category J Condensate Tubing Ref No: Size Max Head m Code List price RTV-1/4 30m x 1/4" clear RTV-1/4 30m x 1/4" black RTV-3/8 30m x 3/8" clear RTV-3/8 30m x 3/8" black RTV-1/2 30m x 1/2" clear RTV-1/2 30m x 1/2" black RTV-1/ m clear Sell Category N RTV-3/ m clear YY Non-Screened 100 metres Grey Code List price 2 core 0.75mm core 0.75mm core 0.75mm core 2.5mm core 2.5mm Also available: Cleats, Conduit, Stuffing Glands, Brass Glands, Terminals, and Connector Blocks Sell category E Sell category A Weatherproof Isolators IP 65 Lockable in either 'on' or 'off' Code List price 20A/5.5kW/4Pole A/11kW/4Pole Important It is the Installer s responsibility to check compliance with Electrical Regulations when selecting cable, components, isolators, and all other electrical equipment

25 Refrigerants Tools & Equipment HRP leads the way in the supply of refrigerants to the UK industry, in partnership with BOC Refrigerants. HRP provides a complete range of refrigerants in a variety of containers, from 1kg cans and dumpy cylinders, to 1000kg drums. Hydrocarbon, CO2 and Ammonia refrigerants are also available to special order. HRP Service Centres are located throughout the UK and hold comprehensive stocks of refrigerant cylinders, plus engineers service tools and scales. Owing to the volatility of Refrigerant Prices, please refer to, or contact your Service Centre. HFC Kg Per Cyl HRP Code Sales Cat G R410A G G HRP Services to Contractors and Engineers Changing Legislation HRP keeps the industry informed of legislation governing the availability of refrigerants, following the ban of R22 (Virgin HCFC). Building owners, landlords, leaseholders and tenants are now required by law to ensure any equipment is de-gassed properly, with an audit trail for the removal, reprocessing/destruction of refrigerants. Cylinder Tracking HRP has an online tracking facility for account customers, using bar coding, and referencing site addresses with cylinder serial numbers. Customers can view their Cylinder Register on line, and can customise their Register with other reference details, including engineers names, etc. Refrigerant Waste Recovery Simplified Procedures HRP has provided a service for refrigerant waste for the last twelve years. HRP recognises that engineers do not like regulations, detest form filling, and have some fear and possibly ignorance of the legislation which now covers Waste. To make life easy, HRP has produced a Consignment Form, in association with the Environment Agency, with much of the required information pre-printed, allowing the contractor to follow several easy steps to comply with the Regulations. HRP provides a comprehensive service of Recovery Cylinders, Delivery & Collection, Forms, responsibilities of Transfer Station, Documentation and Certificates. F-Gas Regulations Effective 4th July If you are involved in refrigerant charging, evacuation, or waste recovery, you must be qualified to City & Guilds 2079 course vacancies are still available at the HRP Technical Centre and Training Facility, which is sponsored by Mitsubishi Heavy Industries. HRP as a huge range of tools and equipment for air conditioning engineers, from hand tools and gauges to electronic scales and vacuum pumps. These are available from any of the HRP Service Centres located throughout the UK. Part Ref Description Sales Cat. Code List Price Tube Cutting & Flaring Kit - ITE 120-F ITE Tube Cutting & Flaring Kit A Tube Bending Kit - Hercules Model-S Tube Bender E Former 3/8" E Slipper 3/8" E Former 1/2" E Slipper 1/2" E Former 5/8" E Slipper 5/8" E Manifold Sets MV12A(1) Manifold 8mm R410A - CPS E /1 Digital Manifold - Testo E /1 Digital Manf'd +gauge - Testo E Vacuum Pump - Autoclimate Stage 1.3 cfm 220V A Stage 4.2 cfm 220V A Stage 6.5 cfm 220V A Vacuum Pump - Robinair 2stage Stage 220V & 110V-60Hz A Stage 220V & 110V-60Hz A A 2 Stage 220V & 110V-60Hz A Refrigerant Scales - TIF TIF9030 Compact Electronic Scales A Capacity 100kG Refrigerant Recovery Mmax 240 Promax Minimax 240V F Mmax 110 Promax Minimax 110V-60Hz F RG5410A-240 Promax 240V F , RG5410A-110 Promax 110V-60Hz F , Vacuum Gauge - CPS VG-100 CPS LED display E VG-200 CPS Digital display E Leak Detector - TIF TIF XP-1A HFC & HCFC Z TIF883 Sensor tip A TIF8806B Battery Charger A

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall

More information

FULL DC INVERTER SYSTEMS

FULL DC INVERTER SYSTEMS FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation

More information

Inverter Air Conditioning for Light Commercial Use

Inverter Air Conditioning for Light Commercial Use Inverter Air Conditioning for Light Commercial Use 02 Cost Saving Comfort An efficient use of time 03 SDISuper Digital Inverter Very efficient energy consumption Keeps down operating costs Heater operation

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

DUCTED AIR CONDITIONING SOLUTIONS

DUCTED AIR CONDITIONING SOLUTIONS DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE

More information

Pioneer in sustainability

Pioneer in sustainability Pioneer in sustainability Over 100 years ago Carrier helped pioneer a new industry, and in the last two decades we have pioneered environmentally sensitive products with a reduced impact on the environment.

More information

Unico Inverter. Unique and efficient.

Unico Inverter. Unique and efficient. Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed

More information

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A More than Air Conditioning Catalogue 2004/2005 Air Conditioning Program R 407C R 410A MITSUBISHI ELECTRIC Air Conditioning Systems As one of the world s leading technology companies, MITSUBISHI ELECTRIC

More information

FTXS. Wall Mount Heat Pump or Cooling Only

FTXS. Wall Mount Heat Pump or Cooling Only FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both

More information

Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73

Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73 MCAC-VTSM-2013-03 R410a Full DC Inverter Mini VRF Contents Part 1 General Information... 1 Part 2 Outdoor Units... 9 Part 3 Installation... 50 Part 4 Troubleshooting 73 Part 5 Control System... 100 Manufacture

More information

-~ available. Power consumption during operation is substantially less than that of lower rated

-~ available. Power consumption during operation is substantially less than that of lower rated Introduction Specifically designed for small to medium sized areas the SANYO SAP range is the ideal solution when you need quiet, efficient room air conditioning to create a comfortable environment within

More information

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System For Residential & Light Commercial Applications 4 Ton 8 Zone Multi Split Heat Pump System EXPERTISE AND INNOVATION The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone

More information

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SiBE12-625 D-Series / E-Series [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SUPER MULTI NX D-Series / E-Series Cooling Only Indoor Unit FTKS20D3VMW FTKS20CAVMB FDKS25CAVMB

More information

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co.,

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW

More information

2015 / 16. price list. Airconditioning systems

2015 / 16. price list. Airconditioning systems 2015 / 16 price list Airconditioning systems TERMS OF BUSINESS General As far as nothing else has been declared, the general terms of business and the agreed purchase conditions including the sales discounts

More information

ECO-AIR AIR CONDITIONING www.northamericanhvac.com

ECO-AIR AIR CONDITIONING www.northamericanhvac.com INDEX ACCESSORIES INSTALLATION... 3-7 LINE SETS... 3-7 GEOTHERMAL... 3-8 WIRING CABLE... 3-8 CIRCULATOR PUMPS (PRO-TECH MODEL)... 3-9 DC INVERTER SINGLE ZONE HEAT PUMP... 3-6 DC INVERTER TECHNOLOGY...

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

FCQ. Roundflow Cassette Heat Pump or Cooling Only

FCQ. Roundflow Cassette Heat Pump or Cooling Only FCQ Roundflow Cassette Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FCQ roundflow cassette SkyAir systems are ideal for open plan applications where variances in temperature and airflow

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS POER, FLEXIBILITY, RESIDENTIAL Carrier presents the new line of multi-split systems A complete and flexible range designed to meet every residential and light

More information

Introduction To VRF: System Overview, Applications, & Savings Opportunities

Introduction To VRF: System Overview, Applications, & Savings Opportunities Introduction To VRF: System Overview, Applications, & Savings Opportunities System Overview What is VRF? Zoning System Two-Pipe / Three Pipe System Packaged DDC Control Operates as a Heat Pump Simultaneous

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

FHQ. Ceiling Suspended Heat Pump or Cooling Only

FHQ. Ceiling Suspended Heat Pump or Cooling Only FHQ Ceiling Suspended Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FHQ ceiling suspended SkyAir systems are ideal for applications without false ceilings. Installed from the structure, this

More information

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing

More information

innovative comfort solutions

innovative comfort solutions engineering and specifications Guide duct-free air conditioning systems Art cool inverter flex multi-split floor standing ceiling cassette PTAC PTHP through-the-wall innovative comfort solutions 1 AT LG,

More information

FBQ. DC Duct Heat Pump or Cooling Only

FBQ. DC Duct Heat Pump or Cooling Only FBQ DC Duct Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FBQ DC Duct systems offer a powerful solution, compact in design and easily concealed in a ceiling. With both cooling only and heat

More information

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW utopia DC Inverter 7kW-14kW G8 5kW-25kW Split Systems Contents Company profile 4 Product range overview 6 Features and benefits 8 DC Inverter 12 Utopia G8 24 Utopia centrifugal 40 Total heat exchanger

More information

Split units TH with hermetic compressors

Split units TH with hermetic compressors Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split

More information

LG Air Conditioning & Energy Solutions Price List

LG Air Conditioning & Energy Solutions Price List LG Air Conditioning & Energy Solutions Price List Valid from March 2015 Splits VRF Heat Pumps Ventilation Controls Introduction About LG Electronics Air Conditioning and Energy Solutions LG manufactured

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

PANASONIC TROUBLE SHOOTING GUIDE

PANASONIC TROUBLE SHOOTING GUIDE A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Replacement VRV Cost effective upgrade for R-22 s High efficiency Possibility to increase capacity Limited and planned downtime Limited and phased investment cost www.daikin.eu

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

Air Conditioning For Large Buildings

Air Conditioning For Large Buildings Air Conditioning For Large Buildings Index Introduction 3 Industry leading energy savings 6 New smart & sensitive VRF control 10 Industry leading layout flexibility 14 Other features 18 Outdoor units Outdoor

More information

DRAFT. 50Hz 14KX03E-1. New

DRAFT. 50Hz 14KX03E-1. New DRFT 50Hz 14KX03E-1 New New 2 Line Up Contents Introduction Outdoor units Indoor units Control systems Corrosion Protection Treatment series 4~15 16~33 34~69 70~79 80. 81 Water cooled series 82. 83 High

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LECA AS G09LECA AS G12LECA AS G14LECA OUTDOOR AO G07LEC AO G09LEC AO G12LEC AO G14LEC 1. INDOOR UNIT : AS G07LECA AS G09LECA AS

More information

PRODUCT CATALOG. Indoor Units

PRODUCT CATALOG. Indoor Units PRODUCT CATALOG Indoor Units Life s Good! From installation to maintenance, LG runs more than 60 global air conditioning academies, each provides training for air conditioning professionals. What is LG?

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

SiUS091133. Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS091133. Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair FTXS-L Series FDXS-L Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair FTXS-L Series FDXS-L Series Cooling Only Indoor Unit FTXS30LVJU

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Gree Solar Hybrid Hi Wall Inverter Air Conditioner Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar

More information

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience

More information

Air Conditioning for Small and Medium-size Buildings

Air Conditioning for Small and Medium-size Buildings Air Conditioning for Small and Medium-size Buildings Defining a HIGHER standard The all-new MiNi-SMMS air conditioner lineup lets you cool or warm as many as 12 *1 rooms with a single system. Outdoor units

More information

M Series. Room Air Conditioning

M Series. Room Air Conditioning M Series Room Air Conditioning The Adaptable M Series Range Available in a variety of options, our M Series range fits in wherever it s needed. Indoor units can be wall or floor mounted. The full M series

More information

NEW 3-PIPE ECOi MF2 SERIES

NEW 3-PIPE ECOi MF2 SERIES NEW 3-PIPE ECOi MF2 SERIES SIMULTANEOUS HEATING AND COOLING VRF SYSTEM Internet Control Ready INTERNET CONTROL NEW Energy Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data C e i l i n g s u s p e n d e d u n i t E E D E N 2-0 0 FHQ-B8 Indoor Unit Ceiling suspended unit FHQ-B8 TABLE OF CONTENTS FHQ-B8 Features.............................................................

More information

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease The NEW Greenstar i innovative intuitive improved performance installation ease A NEW look, NEW features and a NEW NAME for the UK s best selling boiler, the Greenstar i Junior 1 Introducing the new Greenstar

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

squrboxbox heat recovery squrboxbox I technical information

squrboxbox heat recovery squrboxbox I technical information heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution

More information

Air Conditioners. Technical Data. Wall Mounted Unit. www.daikin.eu RX-JV/GV

Air Conditioners. Technical Data. Wall Mounted Unit. www.daikin.eu RX-JV/GV Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV TABLE OF CONTENTS RX-JV/GV 1 Features.............................................................

More information

Submitted to Reference Approval Construction Unit Designation Schedule #

Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL AQV09JA High Wall 9,000 Btu/h Heat Pump Nom Cooling Capacity (Btu/h) 9,000 SEER 20.0 Cool Capacity Range (Btu/h) 3,100 to 11,900 Nom Heating Capacity (Btu/h) 11,950 HSPF 10.0 Heating COP 3.7

More information

IR410AI. The flexible solution. Simple, one touch control

IR410AI. The flexible solution. Simple, one touch control The flexible solution The new SANYO Flexi Multi range of heat pump multi split systems are the ideal, flexible solution for providing quiet and efficient air conditioning to 2, 3 or 4 areas from a single

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT

More information

CADB and CADT-D / DI / DC Series

CADB and CADT-D / DI / DC Series HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised

More information

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit Ref.-No. SMMS02-AE-10-05 Indoor unit 4-way ceiling cassette MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H MMU-AP0561H 2-way ceiling cassette MMU-AP0071WH,

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

Multi Air Conditioner SVC MANUAL(Exploded View)

Multi Air Conditioner SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : A5UW306FA3 CAUTIN Before Servicing the unit, read the safety precautions in Standard SVC manual. nly for

More information

marine/bespoke split applications

marine/bespoke split applications split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments

More information

UDSA - UDSBD unit heater

UDSA - UDSBD unit heater APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the

More information

Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4)

Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4) room air conditioners Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4) Contents Company profile 4 Product range overview 6 Standards and quality certificates 8

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF

More information

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner

More information

www.inspection-for-industry.com

www.inspection-for-industry.com Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008 Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be

More information

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6. TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM

More information

SiUS041111. Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS041111. Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type K-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type K-Series Cooling Only Indoor Unit FTXN09KEVJU

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and 1 Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and cost-effective, Toshiba aims at the heart of growing

More information

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ SERVICE MANUAL Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ FS2MI-147HFD FS2MI-187HFD FS3MI-217HFD FS3MI-277HFD FS4MI-277HFD FS4MI-367HFD FS5MI-367HFD NOTE: Before servicing the

More information

PLA. Advancements in PLA series improve style and performance for ensured indoor comfort. 4-way Ceiling Cassette. Wide Airflow.

PLA. Advancements in PLA series improve style and performance for ensured indoor comfort. 4-way Ceiling Cassette. Wide Airflow. 13 4-way Ceiling Cassette PLA SERIES Advancements in PLA series improve style and performance for ensured indoor comfort Wide Air Wide-angle outlets distribute air to all corners of the room, ensuring

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess

More information

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01 Features and Benefits Two Climatuff compressors Efficiency

More information

All the best brands all under one roof

All the best brands all under one roof All the best brands all under one roof Year round comfort and energy efficiency The air conditioner you choose today is going to be with you for a long time, so it s important to choose wisely. The best

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Ductless Mini-Split Systems. Comfort... where you need it, when you need it Ductless Mini-Split Systems Comfort... where you need it, when you need it Ductless mini-splits THE COMFORT SOLUTION Ductless mini-split systems are a great solution to a wide variety of installation challenges,

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

emura Form. redefined.

emura Form. redefined. emura Form. function. redefined. IT S ALL ABOUT DESIGN if award Daikin Europe N.V. is proud to announce that Daikin Emura has been awarded an if Product Design Award for 2010. For 56 years, the if product

More information

LG AIR CONDITIONERS 2014 Ducted Split System

LG AIR CONDITIONERS 2014 Ducted Split System Australia Pty Ltd. New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : 02-8805-4000 FAX : 02-8805-4248 AUS-DU1309 Queensland 23 Terrace Place MURARRIE QLD 4172 PH : 07-3908-9000

More information

TECHNICAL MANUAL. INVERTER RESIDENTIAL AIR CONDITIONERS (Split system, air to air heat pump type) Ceiling concealed type SRR25ZJ-S SRR35ZJ-S

TECHNICAL MANUAL. INVERTER RESIDENTIAL AIR CONDITIONERS (Split system, air to air heat pump type) Ceiling concealed type SRR25ZJ-S SRR35ZJ-S Manual No.'10 SR-T-091 TECHNICAL MANUAL INVERTER RESIDENTIAL AIR CONDITIONERS (Split system, air to air heat pump type) Wall mounted type SRK20ZJ-S SRK25ZJ-S SRK35ZJ-S 50ZJ-S SRK20ZJX-S SRK25ZJX-S SRK35ZJX-S

More information

SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units

SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units SALES BULLETIN Key Features 1. Chassis completely re designed 2. Increased product range, now includes 6HP model 3. New features to enable easy installation a. Easy access hanger b. Easier wiring connections

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information