TOTALINE UV AIR PURIFIERS
|
|
- Ezra Underwood
- 7 years ago
- Views:
Transcription
1 TOTALINE UVC GERMICIDAL AIR PURIFIERS The Totaline UVC (Germicidal) Air Purifiers are designed to work with the ventilation system to reduce airborne contaminants such as legionella, molds, bacterial and viruses. In addition, the units assist in alleviating symptoms associated with asthma, and allergies. They recreate the effects of sunlight by naturally decomposing, destroying and purifying contaminates. Totaline Air Purifiers are available in 5 models to suit both residential and commercial needs. Features: Produces no ozone, gases or fumes. Patented technology, unique J shaped lamp. Easy installation. Multiple installation options permits remote mounting or bypass mounting. Test button and inspection port (Commercial in-duct). Commercial in-duct models work only when the HVAC blower is functioning. Low power consumption and no increase with duct system resistance. No maintenance (excluding bulb changes). NRTL/C, CSA certified. 3 year warranty on residential models. P2002 Totaline Air Purifiers ITEM DESCRIPTION P103-R1500G Residential, covers up to 1500 sq. ft. P103-R3500G Residential/Lt. Commercial, covers up to 3500 sq. ft. P103-CC2020 Commercial, Coil Clean P103-CT200G Commercial, for uses up to 2000 cfm P103-CMT100G Commercial, ceiling mount, covers up to 500 sq. ft. P103-PT100G Portable, covers up to 1250 sq. ft. P103-RRPUVL-012 Residential, Return Plenum UV Light 12 P103-RRPUVL-018 Residential, Return Plenum UV Light 18 P103-RTUVL-024 Commercial, Rooftop UV Light 24 P103-RTUVL-030 Commercial, Rooftop UV Light 30 P103-BIOBARRIER40 Commercial, In-Duct UV Light 40 P103-BIOBARRIER50 Commercial, In-Duct Light 50 P103-BIOBARRIER60 Commercial, In-Duct UV Light 60 P103-S1000G-25 Commercial, UV Air Purifier and Filter *Also available in 220 volt. Options for Totaline Air Purifiers P103-REMINSKT001 P103-TUBESTND001 P103-S1000G-25-CRKIT ITEM DESCRIPTION Remote Installation Kit Tubular Stand for P103-PT100G Clean Room Upgrade Kit for P103-S1000G
2 TOTALINE UVC GERMICIDAL AIR PURIFIERS (cont) Other Parts Information for Totaline Air Purifiers ITEM DESCRIPTION P103-GERMLAMP004 Germicidal J Lamp for P103-PT100G, P103-CMT100G, P103-R1500G P103-GERMLAMP005 Germicidal J Lamp for P103-R3500G P103-GERMLAMP006 Germicidal J Lamp for P103-CT200G, P103-S1000G-25 P103-GERMLAMP007 Lamp for P103-RTUVL-030 P103-GERMLAMP008 Lamp for P103-CC2020 P103-GERMLAMP009 Lamp for P103-RRPUVL-012 P103-GERMLAMP010 Lamp for P103-RRPUVL-018 P103-GERMLAMP011 Lamp for P103-RTUVL-024 P103-GERMLAMP40 Lamp for Bio-Barrier 40 P103-GERMLAMP50 Lamp for Bio-Barrier 50 P103-GERMLAMP60 Lamp for Bio-Barrier 60 P103-BALLAST-001 Ballast for P103-R3500G P103-BALLAST-002 Ballast for P103-CT200G, P103-S1000G-25 P103-BALLAST-003 Ballast for P103-PT100G, P103-CMT100G, P103-R1500G P103-BALLAST-004 Ballast for P103RRPUVL-012/018 P103-BALLAST-005 Ballast for P103-RTUVL-024/030 P103-BALLAST-006 Ballast for P103-CC2020 P103-BALLAST-BIOBARRIER Ballast for Bio-Barrier 40, 50, 60 P103-SPDCNTL-001 Speed Control for P103-PT100G P103-VACUSTSW001 Vacuum Starting Switch for P103-CT200G SAN-COO2 Turbulator P103-S1000G-25-FILTER 99.97% HEPA Replacement Filter for P103-S1000G-25 Merchandisers P103-RRPUVL-SAMPLEKIT P103-R3500G-SAMPLEKIT ITEM DESCRIPTION Residential, Return Plenum UV Light 12 and Display Case R3500G Air Purifier and Display Case 373
3 The Totaline P103-R1500G and P103-R3500G are designed to be installed on the supply side of the return air duct. As the airflow passes through the P103-R3500G Chamber, the ultraviolet process helps to destroy biological contaminants. RESIDENTIAL-LIGHT COMMERCIAL IN-DUCT AIR PURIFIER P103-R3500G P103-R1500G P2003 MODEL P103-R1500G P103-R3500G Application Residential Residential/Light Commercial Purifying Capacity 1500 sq. ft sq ft. 9.5x8 in. (241x203 mm) 12x8 in. (305x203 mm) Plenum Opening Requirements 8x6 in. (203x152 mm) 11x6 in. (269x152 mm) 4.4 lbs (2 kg) 12 lbs (5.5 kg) 120V,15Watts 120V,25Watts Hardwire Germicidal UV Single Zone Lamp Lamp Diameter 19 mm 19 mm Proprietary UV J Lamp Dimensions 6.5 in. (165 mm) 10.5 in. (267 mm) Lamp Arc Length 10.5 in. (267 mm) 17.7 in. (450 mm) Air Exposure Time to UV Lamp Per Pass: in 500 ft per minute On High Speed On Low Speed UV Intensity Inside Aluminum Tube/Housing 7456 Microwatts per/cm 2 12,176 Microwatts per/cm 2 Fan Speed Noise 5 ft Aluminum UV Reflector 5x7.875 in. Tube (127x200 mm) 5x12 in. Tube (127x305 mm) Inlet/Outlet Filter Construction Steel/Powder Coat Paint Steel/Powder Coat Paint Certification NRTL/C, CSA NRTL/C, CSA Options Remote Installation Kit Remote Installation Kit Residential Warranty: 3-Year Including UV Lamp and Parts Commercial Warranty: 12,000 hrs on UV Lamp 1-Year on Parts 374
4 COMMERCIAL IN-DUCT AIR PURIFIER The Totaline P103-CT200G is a commercial purifier. With a powerful UVC source, the P103-CT200G is designed to be installed on the supply side of the return air duct. Air passes through the Chamber and the ultraviolet process helps destroy the biological contaminants. P103-CT200G P1524 MODEL Application Purifying Capacity Plenum Opening Requirements Hardwire Germicidal UV Single Zone Lamp Lamp Diameter Proprietary UV J Lamp Dimensions Lamp Arc Length P103-CT200G Commercial 2000 cfm 20x9 in. (508x228 mm) 18x7 in. (457x178 mm) 15 lbs (6.8 kg) 120V,45Watts Optional 19 mm 16 in. (406 mm) 31.2 in. (793 mm) AirExposureTimetoUVLamp PerPass: in 500 ft per minute 400 On High Speed On Low Speed UV Intensity Inside Aluminum Tube/Housing 9497 Microwatts per/cm 2 Fan Speed NoiseLevel@5ft Aluminum UV Reflector 7x19 in. Tube (178x483 mm) Inlet/Outlet Filter Construction Steel/Powder Coat Paint Certification NRTL/C, CSA Options Remote Installation Kit Residential Warranty: 3-Year Including UV Lamp and Parts Commercial Warranty: 12,000 hrs on UV Lamp 1-Year on Parts Sizing Guidelines Offices, Schools and Commercial Applications: Hospitals, Labs, and Areas Requiring High Germicidal Doses: 1 per 1800 cfm 1 per 1000 cfm 375
5 CEILING TILE MOUNT AIR PURIFIER TOTALINE UV AIR PURIFIERS The Totaline P103-CMT100G ceiling tile mount UV air purifier is an innovative design. The P103-CMT100G s space saving 24 x 24 design easily installs in the opening of a ceiling tile. Quiet operation and its ability to purify an area of up to 4,000 cubic feet using a UV process, makes this purifier the ideal solution for indoor air quality problems. MODEL P103-CMT100G Application Commercial Ceiling Tile Purifying Capacity 500 sq. ft 24x24x9 in. (610x610x229 mm) Plenum Opening Requirements 28 lbs (13 kg) 120V,26Watts Hardwire Germicidal UV Single Zone Lamp Lamp Diameter 19 mm Proprietary UV J Lamp Dimensions 6.5 in. (165 mm) P1524A Lamp Arc Length Air Exposure Time to UV Lamp Per Pass: in 500 ft per minute 10.5 in. (267 mm) P103-CMT100G On High Speed On Low Speed 160 milliseconds UV Intensity Inside Aluminum Tube/Housing 7270 Microwatts per/cm 2 Fan Speed 71 cfm NoiseLevel@5ft Less than 49 dba Aluminum UV Reflector 21x7x9 in. Box (533x178x229 mm) Inlet/Outlet Filter 14x8 Polypropylene 14x8 Activated Carbon Construction Steel/Powder Coat Paint Certification NRTL/C, CSA Options Residential Warranty: 3-Year Including UV Lamp and Parts Commercial Warranty: 12,000 hrs on UV Lamp 1-Year on Parts 376
6 PORTABLE AIR PURIFIER The Totaline P103-PT100G is designed to be the most versatile purifier on the market, reducing biological contaminants, with all the benefits of ultraviolet technology in a portable purifier weighing only 13 lbs. The P103-PT100G can be used continuously or when the need arises. Easily transported, the P103-PT100G is ideal for anyone in need of a cost effective, simple solution for the problems associated with indoor air quality. P103-PT100G P2129 MODEL Application Purifying Capacity Plenum Opening Requirements Hardwire Germicidal UV Single Zone Lamp Lamp Diameter Proprietary UV J Lamp Dimensions Lamp Arc Length Air Exposure Time to UV Lamp Per Pass: in 500 ft per minute On High Speed On Low Speed P103-PT100G Portable 800 sq. ft x11.75x in. (92x298x475 mm) 13 lbs (5.9 kg) 120V,85Watts 19 mm 6.5 in. (165 mm) 10.5 in. (267 mm) 25 milliseconds 116 milliseconds UV Intensity Inside Aluminum Tube/Housing 7380 Microwatts per/cm 2 Fan Speed 40/150 cfm variable NoiseLevel@5ft High 60 dba, Low 49 dba Aluminum UV Reflector 2.5x8.5x9 in. Box (63.5x215.9x228.6 mm) Inlet/Outlet Filter Aluminum Mesh Construction Steel/Powder Coat Paint Certification NRTL/C, CSA Options Stand Residential Warranty: 3-Year Including UV Lamp and Parts Commercial Warranty: 12,000 hrs on UV Lamp 1-Year on Parts 377
7 UVC GERMICIDAL OBJECT IRRADIATORS P103-RRPUVL-012 P103-RRPUVL-018 P4000 RESIDENTIAL The Totaline Fusion is our entry level Ultraviolet Air Purifier which employs a High Intensity Quartz UV Germicidal Lamp to destroy biological contaminants such as mold, bacteria and viruses; it is designed to kill. The Fusion uses UVC Energy to slice through the air, destroying the biological contaminants which come in contact with the KillZone.TheFusionisavailableintwosizes,a12in.or18in.lamp,dependingon duct size. Fusion is installed in the return plenum, limiting the amount of contaminants that come in contact with the filter and coil. Because the Fusion uses a high intensity 19 mm quartz lamp, only one lamp is needed, while other manufacturers need multiple lamps to obtain the same intensity. This is an added benefit, as lamp changes will be limited to one not two or more lamps per year. Extremely simple to install with lamp changes taking just seconds, the Fusion is a cost-effective method for home purification. P103-RTUVL-024 P103-RTUVL-030 P4025 COMMERCIAL The Totaline CoilClean RT is specifically designed for exterior rooftop HVAC units. The CoilClean RT employs technology to reduce biological contaminants including mold and fungus on the A/C coil. It uses a weatherproof NEMA 4X Housing, a high-intensity 19 mm quartz germicidal lamp and an aluminum parobolic reflector to direct and intensify the UV energy that would otherwise be lost, ensuring a coil free from microbial growth. No other company offers a complete line of high efficiency UV Air Purifiers and Coil Cleaners to suit virtually any commercial application. UV AIR PURIFIER & FILTER The S1000G-25 is a combination Ultraviolet/Filter Air Purifier. It is designed to destroy harmful pollutants and biological contaminants. This unit consists of one 16 UVC J shaped lamp, two 1 pre-filters and one 4 95% efficient ASHRAE filter. In addition to the patented UV process, the S1000G-25 Clean Room option is also available and includes an extra 16 UVC J shaped lamp (making a total of two for even more purification), and changing the 95% filter for a 99.97% HEPA filter. The clean room option is typically used for hospitals, day care centers, etc. This unit is equipped with a 1750 CFM blower and can be installed into the existing ventilation system or can be used as a stand-alone unit. P4373 P103-S1000G-25 P4373A 20x20x41 in. Mounting 3 sets of four 1/4 in. threaded mounting brackets 59 lbs Air Inlets 2x8 in. Air Outlets 2x8 in. 120 Volt, 360 Watts, 60 Hz Power Rating 1750 CFM Airflow Underload CFM UV Lamp Dimensions J Type (Proprietary) Ultraviolet Split Lamp 19 mm, Dia. 16 in. Lamp Arc Length 31.2 in. AirExposureTimetoUVLamp Per Pass 43 milliseconds UV Intensity Inside UV Reflector 8,740 microwatts per/cm 2 UV Reflector 10x20 in. Aluminum Outlet Noise 5 ft (no duct attached) 59 dba Enclosure Noise 5 ft 54 dba Prefilters (2) 1 in. media filter Main Filter 19.5x19.5x4 in., 90-95% ASHRAE Chassis & Paint Aluminum, Powder Coat Options Various 19.5x19.5x4 in. Media Filters, Clean Room Option w/extra Lamp & HEPA filter 378
8 COMMERCIAL UV GERMICIDAL AIR PURIFIER/COIL CLEANER The Totaline P103-B30G UV Air Purifier/Coil Cleaner is designed for easy aftermarket installation on Bard Wall Mount HVAC units. The P103-B30G uses UV-C energy to destroy bio-chemical contaminants such as mold, mildew, fungus spores, viruses and bacteria without producing ozone. The patented Parabolic Reflector/Shield uses the full 360 degrees of UV light to eradicate contaminants in the air and on the coil while protecting plastics and people from the UV exposure. Features: Easy aftermarket installation. Treats the air and destroys mold on the coil. Eradicates viruses and bacteria. Patented Parabolic Reflector increases intensity. Shields eyes from UV exposure. Protects motor windings, plastics and people from UV exposure. : Dimensions Ballast Safety UV Lamps (2) UV Lamp Features UV Lamp Length UV Intensity in Fw/cm 2 (Microwatts) Parabolic Reflectors (2) x 10.5 inches (778 mm x mm) 10 lbs. (4.5 kg) 208/230 VAC Electronic Rapid Start Power Interlock Switch High Intensity 19 mm Germicidal Pure Fused Quartz Getter Absorbs Inner Lamp Contaminants, Low Mercury Levels 30 inches (763 mm) 360 Microwatts per cm 2 at 1 Meter inches (778 mm) Length P
9 COMMERCIAL UV GERMICIDAL BIOBARRIER The UV BioBarrier is individual UV Arrays which work together in providing a barrier wall of Germicidal UV Energy which will kill 99.9% of biological contaminants which pass through it. Each BioBarrier has 5 High Intensity 19mm Quartz Lamps which are mounted to Parabolic Reflectors that reflect a full 360 of Germicidal Radiation. The BioBarrier is mounted parallel to the airstream in order to maximize the contaminant s contact time with the UV Energy. The number and size (offered in either 40, 50, or60 lengths) of the Arrays will depend on the size of the duct, the velocity of the air moving within the duct, the specific contaminants to be treated and the desired percent kill. P4372 P4372A MODEL P103-BIOBARRIER40 P103-BIOBARRIER50 P103-BIOBARRIER50 Application Commercial Commercial Commercial Overall Diameter 5.25 Inches 5.25 Inches 5.25 Inches Cone Diameter 3.5 Inches 3.5 Inches 3.5 Inches Length Bio-Barrier 46.5 Inches 56.5 Inches 66.5 Inches Ballast Box 22.5 x 9.5 Inches 22.5 x 9.5 Inches 22.5 x 9.5 Inches Aluminum Parabolic Reflectors 5 Reflectors 5 Reflectors 5 Reflectors High Intensity UVC Lamps 5 UVC Lamps 5 UVC Lamps 5 UVC Lamps Bio-Barrier 20 lbs. 24 lbs. 28 lbs. Ballast Box 14 lbs. 14 lbs. 14 lbs. 120 V AC or 277 V AC 120 V AC or 277 V AC 120 V AC or 277 V AC 50/60 Hz, 5.5 Amps 50/60 Hz, 6.5 Amps 50/60 Hz, 7.5 Amps High Intensity UV Lamp Germicidal Pure Fused Quartz Germicidal Pure Fused Quartz Germicidal Pure Fused Quartz Lamp Diameter 19 mm 19 mm 19 mm Lamp Length 40 Inches 50 Inches 60 Inches UV Intensity in uw/cm 2 (microwatts) Per Lamp 540 microwatts per/ 600 microwatts per/ 660 microwatts per/ Combined UV Intensity in uw/cm 2 (microwatts) 2700 microwatts per/ 3000 microwatts per/ 3300 microwatts per/ Ballast Electronic Instant Start Electronic Instant Start Electronic Instant Start Wire Set (Pairs) (5) Color, 20 ft, 18 AWG 19 Strand (5) Color, 20 ft, 18 AWG 19 Strand (5) Color, 20 ft, 18 AWG 19 Strand UL1716 Teflon Wire UL1716 Teflon Wire UL1716 Teflon Wire Electronic Counter Resettable Hour Accumulating Resettable Hour Accumulating Resettable Hour Accumulating Counter Counter Counter LED Indicators LED Indicators for Each Lamp LED Indicators for Each Lamp LED Indicators for Each Lamp Audible Buzzer Indicates Lamp Out Condition Indicates Lamp Out Condition Indicates Lamp Out Condition Commercial Warranty 10,000 Hours on UV Lamp 1 Year on Parts 10,000 Hours on UV Lamp 1YearonParts 10,000 Hours on UV Lamp 1 Year on Parts 380
There are several types of air cleaning devices available, each designed to remove certain types of pollutants.
Please Note: EPA neither certifies nor recommends particular brands of home air cleaning devices. While some home air cleaning devices may be useful in some circumstances, EPA makes no broad endorsement
More informationToday, healthcare facilities must be prepared to face
Alternate Methods for USING GERMICIDAL UV-C Disinfection Lamps TO SUPPLEMENT HEPA Filtration By Dave Shagott Today, healthcare facilities must be prepared to face potential large-scale threats from chemical,
More informationInstallation Instructions WARNING: WARNING: WARNING: WARNING: WARNING:
Installation Instructions Ultra-Violet Air Purifier Residential/Commercial Duct Installation Applications - RX4000, RX4000B, RX1700 SAFETY CONSIDERATIONS Installation and servicing of air-conditioning
More informationWARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:
Revision Level: 01 Revision Date: 07/07/2011 Please read all instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Air Purifier. Failure to do
More informationindoor Air quality products Air Filtration Ventilation Purification Humidification
indoor Air quality products Air Filtration Ventilation Purification Humidification how clean is the air in your home? According to the Environmental Protection Agency (EPA), American homeowners spend about
More informationIlluminating Info: UV-C For HVAC
Page 1 of 6 Home Illuminating Info: UV-C For HVAC Looking for lifecycle guidance or more extensive info for your stationary appli-cations? An industry IAQ veteran weighs in about the design, installation,
More informationIntroduction to Use of UV Light For the Control of Air Handler Contamination. What is UVGI or Ultraviolet Light?
Introduction to Use of UV Light For the Control of Air Handler Contamination By Chris Willette Since the energy crisis of the 70 s, we have been forced to build our homes tighter and tighter to save on
More informationMake your home a healthier home
Whole House Germicidal Ultraviolet Air Treatment For Healthier Living Make your home a healthier home Whole House Germicidal UV Air Treatment UltraMAX uses UV light to kill MILLIONS of bacteria, viruses,
More informationPower consumption (kw)
OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components
More informationClass II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health
Background Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health This document provides guidelines for the design and installation of Class
More informationFTXS. Wall Mount Heat Pump or Cooling Only
FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both
More informationVentilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech
Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling 2 Ductless Ventilation & Fresh Air Solutions We can fill your home with healthy, fresh air Indoor Air Pollution is real, and it
More informationA. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
More informationEVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.
EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. A Regal Brand EVERGREEN SOLUTIONS Powered by ECM Technology Upgrade/Replace PSC motors with Evergreen IM Residential/Light Commercial HVAC Systems Reduce
More informationUltraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930
Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930 WARNING Ultraviolet light is harmful to eyes and skin. Never look at light produced by this lamp. Unplug lamp before servicing. Electrical
More informationSap Steady UV Unit for Maple Sap
Cornell Maple Bulletin 203 (2007) Sap Steady UV Unit for Maple Sap by BRIAN CHABOT Overview Components The Sap-Steady unit from FPE Inc. (Macedon NY) has been designed to kill bacteria yeast, and some
More informationInstallation Instructions
Installation Instructions Accessory Ultraviolet (UV) Germicidal Lamp 1 & 2 Lamp Models 115-v & 208/230-v UV Lamp C03009 Fig. 1 Two Lamp Model UV Lamp NOTE: Read the entire instruction manual before starting
More informationUses No Chemicals. Ozone Reverts Back to Oxygen. Eliminates Odor Electronically. Operates Unattended. Retards Bacterial Growth. Rapid Removal of Odors
Sonozaire Odor Neutralizers are industrial ozone generators for odor control and air purification. Howe-Baker and our distributors have served the odor control business with the Sonozaire models since
More informationFresh Air Enclosure Cooling Filter Fans
763.576.3200 SPEC-00306 K763.422.2211 COOLING FRESH AIR ENCLOSURE COOLING FILTER FANS Fresh Air Enclosure Cooling Filter Fans TFP SIDE-MOUNT TFP10 215 CFM (365 m3/hr.) TFP6 140 CFM (238 m3/hr.) TFP4 55
More informationAQUADA UV Eliminate Bacteria in Your Drinking Water!
AQUADA UV Eliminate Bacteria in Your Drinking Water! Protect your Family from Micro-Organisms Legionella pneumophila Legionella pneumophila even extremely resistant bacteria are safely destroyed in your
More informationDehumidification Frequently Asked Questions
Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful
More informationHEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions
HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom Frequently Asked Questions What is a negative air machine and why do I need one?
More informationTrane s Position on UV-C Lights
Trane s Position on UV-C Lights Note: The following Trane corporate position statement was issued on October 6, 2008. Trane monitors technologies that offer the potential to improve indoor air quality
More informationLaminar Flow Cabinets
Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical
More informationAir Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg 83 84 85 85 86 88 89 90
6 Air Movement Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners Pg 83 84 85 85 86 88 89 90 83 Air Movement JKI Heaters Aurora Bathroom Heater Quartz 2
More informationPS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: info@juicegoose.com www.juicegoose.com 06-06 CONGRATULATIONS
More informationUsing UltraViolet Light In HVAC Systems
Using Ft. Wayne UltraViolet ASHRAE Light Seminar HVAC Systems Ft. Wayne ASHRAE Seminar July 25, 2006 Using UltraViolet Light In HVAC Systems Lower Energy Consumption Reduce Maintenance Costs Improve Air
More informationInstaller s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
Installer s Guide 18-GJ11D1-2 : Models: BAYUVCLK001-40 Watt, 2 Lamp NOTE: A BAYCC24VK01 can be installed for Series 8 Air Handlers to extend the life of the lamp. This accessory kit will disable the lamp
More informationInstallation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG
Installation and Operating Manual Model F1800C Model F1800PG Model F180C Model F180PG Model F1806C Model F1806PG www.ipsystemsusa.com Contents Safety Warnings... Items supplied... Description... Installation...4
More informationCentro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationRobert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade
Robert McCabe Director, Health Care Solutions HTS Chicago Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade Biography Robert McCabe has been involved in commercial
More informationWhisperGreen Select Ventilation Fans
FV-05-11VKS1, FV-05-11VK1, FV-11-15VK1 FV-05-11VKSL1, FV-05-11VKL1, FV-11-15VKL1 WhisperGreen Select Ventilation Fans n Customizable, all-in-one fan and fan/led light combinations n Pick-A-Flow speed selector
More informationPerformance 17 Two-Stage Air Conditioner with Puron Refrigerant
Performance 17 Two-Stage Air Conditioner with Puron Refrigerant TM Enhanced Comfort, Tax Credit Eligible Cooling Things to Consider Before You Buy Puron Refrigerant Puron refrigerant is environmentally
More information[see Figure 3 below] Ferrite tile walls and ceiling RF Absorber parcel walls and ceiling Removable floor section to make fully anechoic
Test Room ID: R21F Description: SEMI ANECHOIC SHIELDED TEST ENCLOSURE Primary Testing Uses: FCC, CE Mark Dimensions: 9.75m x 6.10m x 5.49m (32ft. x 20ft. x 18ft.) [see Figure 3 below] Construction: Galvanized
More informationExplosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
More informationSun-Pure Air Purifier
Sun-Pure Air Purifier Model SP-20 User s Guide SP20 REVC Manufactured by Ultra-Sun Technologies Corona, California Ultra-Sun Technologies Corona, California U.S.A. IMPRTANT SAFETY INSTRUCTINS Always unplug
More informationCoway Air Purifier AP-1008DH
Coway Air Purifier AP-1008DH This product is for domestic use only.it cannot be used in an overseas country where the power voltage is different. Warranty card is included in this user s manual. Read and
More informationUV100A Ultraviolet Air Treatment System
UV100A Ultraviolet Air Treatment System INSTALLATION INSTRUCTIONS APPLICATION When installed in forced air heating and cooling systems, the UV100A Ultraviolet Air Treatment System kills airborne microorganism
More informationElectrostatic or Electronic: Know the Facts By Robert P. Scaringe, P.E., Ph.D., ---President of Mainstream Engineering
Electrostatic or Electronic: Know the Facts By Robert P. Scaringe, P.E., Ph.D., ---President of Mainstream Engineering HVAC system air filter upgrades are one way contractors can simultaneously increase
More informationEnergy Efficiency. Energy Efficient Home Cooling:
Energy Efficiency Energy Efficient Home Cooling: Choosing an air conditioning system is an important decision. A poor choice may be costly to purchase and operate and yet fail to provide the desired cooling
More informationUltra-Violet Products Ltd 2066 W 11th Street, Upland, CA 91786 Unit 1, Trinity Hall Farm Estate
UV/Air Circulator For the UV PCR Workstation User Instructions UVP, LLC Ultra-Violet Products Ltd 2066 W 11th Street, Upland, CA 91786 Unit 1, Trinity Hall Farm Estate Tel: (800) 452-6788 / (909) 946-3197
More informationComponents HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis
Components HVAC General System Selection Life Cycle Cost Analysis Outdoor Air Design Values Indoor Air Design Values Outdoor Air Ventilation Welding Ventilation Temperature Control Systems Ductwork HVAC
More informationElement D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
More informationSECTION 10811 ELECTRIC HAND DRYERS
SECTION 10811 ELECTRIC HAND DRYERS Display hidden notes to specifier. (Don't know how? Click Here) ** NOTE TO SPECIFIER ** Excel Dryer, Inc.; Electric Hand Dryers. This section is based on the products
More informationOperation and Installation Manual. Max Series
Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat
More informationMAC 10. Original & IQ FAMILY OF FAN FILTER UNITS
MAC 10 Original & IQ FAMILY OF FAN FILTER UNITS used in: microelectronics medical device semiconductor disk drive laboratory pharmaceutical markets hospitals clean rooms Table of Contents MAC 10 Original
More informationTECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES
TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change
More informationTechnical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
More informationCOLUMBIA UNIVERSITY HEALTH SCIENCES DIVISION
COLUMBIA UNIVERSITY HEALTH SCIENCES DIVISION ENVIRONMENTAL HEALTH & SAFETY Working Safely with Ultraviolet Radiation Policy and Procedures Purpose: To provide information and guidelines for the safe use
More informationSINGLE PACKAGE VERTICAL AIR CONDITIONERS
SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,
More informationInstallation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
More informationHVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.
HVAC Systems and Indoor Air Quality Douglas K. Spratt, M.Sc., P.Eng. The 5 Senses Architecture Electrical Structural Mechanical Hearing Seeing Smelling Feeling Tasting HVAC Systems are Dynamic Heat Gains
More informationOwner s Manual Model 5000 Safety, Operating and Maintenance Instructions
Electronic Air Cleaner 90-1147 Owner s Manual Model 5000 Safety, Operating and Maintenance Instructions READ AND SAVE THIS MANUAL WARNING 120 Volts may cause serious injury from electrical shock. Disconnect
More informationTHERMOLEC ELECTRIC DUCT HEATERS www.thermolec.com
INDEX THERMO-AIR AND THERMO-ZONE FRESH AIR HEATERS ELECTRIC FRESH AIR HEATERS... 2-4 FEATURES AND SPECIFICATIONS... 2-3 INSTALLATION INSTRUCTIONS... 2-4 2-5 TYPICAL APPLICATIONS... 2-2 FEATURES... 2-6
More informationEXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
More informationsqurboxbox heat recovery squrboxbox I technical information
heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution
More informationLANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX
LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX The Lantana Luminaire linear light fixture is designed to seamlessly integrate with compatible Lutron control systems. It can be easily
More informationDuroSite TM High Bay Lighting
DuroSite TM High Bay Lighting LED White Lighting Brochure for Industrial Applications CE version Application: The first of its kind, the Dialight DuroSite TM LED High Bay luminaire was designed specifically
More informationDownflo workstation DuSt ColleCtorS
Downflo WorkStation Dust Collectors Outperforms All Other Collectors Downflo WorkStations (DWS) fit anywhere on the plant floor and apply NO restrictions to worker movements or visibility. The full line
More informationProcedures for the Effective Use of Biological Safety Cabinets
Procedures for the Effective Use of Biological Safety Cabinets APPROVAL DATE BY BIOHAZARDS SUBCOMMITTEE: August 10, 2012 SUPERSEDES: March 1, 2012 This corporate guideline/procedure is intended as a minimum
More informationStainless Steel Worksurface 3 Feet Hood A10-WS-PR3 A10-WS-SR3 4 Feet Hood A10-WS-PR4 A10-WS-SR4 6 Feet Hood A10-WS-PR6 A10-WS-SR6.
Product Sampler #1 Laminar Flow Hoods / Laminar Flow Cabinets: 1- Benchtop Vertical Laminar Flow Hoods- Air Recirculation Available s: Clean Bench Class 100 Bench-top Vertical Laminar Flow Hoods with Air-recirculation
More informationNewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
More informationNewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
More informationPlease read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
More informationSingle Package Vertical Air Conditioners. Vert-I-Pak
Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better
More informationFrequently Asked Questions Generators
Frequently Asked Questions Generators Fuel Related How much fuel do the generators use during normal operation? At exercise? The generator fuel consumption is given in each of the product knowledge books
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
More informationREME HALO by RGF A Guardian Air Purification System New Advanced Environmental Air Treatment System
REME HALO by RGF A Guardian Air Purification System New Advanced Environmental Air Treatment System Thank you for purchasing the REME HALOTM by RGF Environmental Group, Inc. We are confident this system
More informationCal Water 1961 Petra Lane, Placentia, CA 92870 (800) CAL-WATER (800) 225-9283 FAX: (714) 792-0794 http://www.cal-water.com
Industrial Water Purification MAINTAINING A STERILE HIGH PURITY WATER SYSTEM Introduction Maintaining a microbe free deionized water system is like trying to maintain a vacuum, and nature abhors a vacuum.
More informationLow Cost. Lower Energy Costs. Higher Efficiency.
HI-E DRY dehumidifiers remove two to three times more water per kilowatt hour of electricity than conventional dehumidifiers. Low Cost. Lower Energy Costs. Higher Efficiency. Therma-Stor designed an efficient,
More informationDuct Design. Presented by Dave Janquart
Duct Design Presented by Dave Janquart Overview of Topics Duct design Duct insulation SMACNA Standards Factors Influencing Duct Design Equipment Losses Air Velocity Duct Material Duct Size & Shape Length
More informationFIRE DAMPER APPLICATION GUIDE
FIRE AND CEILING RADIATION DAMPERS FIRE DAMPER APPLICATION GUIDE Use this application guide to help determine what type of fire damper best suits the application. Below are listed the ten Metal-Fab fire
More informationHigh Bay Occupancy Sensor Selection Guide
High Bay Occupancy Sensor Selection Guide Make the most of your energy SM 1 2 Schneider Electric offers a vast array of lighting control sensors for HID and Fluorescent High Bay applications. HID High
More informationDAIKIN DUCTLESS HEATING AND COOLING SYSTEMS ABSOLUTE COMFORT BEGINS AT HOME.
DAIKIN DUCTLESS HEATING AND COOLING SYSTEMS ABSOLUTE COMFORT BEGINS AT HOME. WHY INSTALL A DAIKIN DUCTLESS HEATING AND COOLING SYSTEM? COMFORT MAKES A HOUSE A HOME. But fluctuating temperatures and noisy,
More informationElectric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions
Self-Retracts 30ft Cable Length Electric Vehicle Charging Station Products EVoReel Safe, Convenient & Clean EV Charging EVoReel products are engineered to provide improved safety and convenience for electric
More informationLAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL
LAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL ENVIRCO Technical Support: 800-884-0002 Table of Contents WARNING... 3 INTRODUCTION... 3 FEATURES... 4 APPLICATIONS... 4 ASSEMBLY...
More informationGreensource iseries HY Model Unitary Air Handler/Fan Coil
Engineering Submittal Sheet Overview Model Nomenclature HY 035 00-1 HY - HYDRONIC AIR HANDLER NOMINAL CAPACITY IN THOUSANDS OF BTUH VOLTAGE DESIGNATION 1 = 208-230/1/60 ELECTRIC HEAT KW 00 - NO ELECTRIC
More informationIII. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136
More informationSPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY
SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY Construction Criteria The unit costs for (Wet) space types are based on the construction quality and design features in the following table. This
More information1.2 Refrigerant Equipment. General
Part 1 General 1.1 Summary.1 Unless otherwise indicated, follow the standards below when specifying heating, ventilation and air conditioning (HVAC) work. These standards are not intended to restrict or
More informationOperating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
More informationAABC Specifications for Testing and Balancing HVAC Systems
AABC Specifications for Testing and Balancing HVAC Systems The Associated Air Balance Council (AABC) Total System Balancing Specifications for HVAC Testing, Balancing and Performance Verification TOTAL
More informationCADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
More informationTerms of Reference Air Handling Unit (HVAC System) Cleaning
Terms of Reference Air Handling Unit (HVAC System) Cleaning Introduction General cleaning of the air handling units is currently undertaken by the Mechanical Division staff composing of 3 personnel. Cleaning
More informationDRYER VENTING SPECIFICATIONS DRYER SAFETY
DRYER VENTING SPECIFICATIONS Table of Contents DRYER SAFETY...1 INSTALLATION REQUIREMENTS...4 Venting Requirements...5 DRYER INSPECTION AND CLEANING...7 Frequency of Exhaust System Cleaning...7 Inspecting
More informationThe Silencer. Silencer Outdoor Air Blower, The Name That Says It All. Quality Product. Call 1-800-848-3077 for more information
The Silencer The Silencer is our most popular outdoor-rated air blower for one simple reason. It s quiet! Turn on your Silencer day or night, and you won t disturb the neighbors or ruin your relaxing spa
More informationPump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationINSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER The instructions that follow are to assist you in completing the information required when making a fan or blower selection. If you need additional
More informationVentilation Solutions Radon Mitigation
Ventilation Solutions Radon Mitigation 2 Radon Mitigation Radon is a health hazard with a simple solution Radon is everywhere! You can t see radon and you can t smell it or taste it, but it may be a problem
More informationFlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.
Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE. Vertical Laminar Flow Cabinets BEYOND MINIMUM SAFETY REQUIREMENT Cabinets are ISO Class 3 vertical laminar flow cabinets which
More informationSECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
More information+by RGF A Guardian Air Purification System New Advanced Environmental Air Treatment System
REME TM +by RGF A Guardian Air Purification System New Advanced Environmental Air Treatment System Thank you for purchasing the REME TM + By RGF Environmental Group, Inc. We are confident this system will
More informationDuplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard
Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard Duplexvent DV72 EC MVHR is designed to provide constant volume ventilation levels to exceed the latest Building Regulations 2010. The
More informationIntelli-Pro Air Purifier (Model: XJ-3800)
Intelli-Pro Air Purifier (Model: XJ-3800) Instruction Manual (Please read before using air purifier) Surround Air Division Indoor Purification Systems, Inc. 334 Marshall Way, Suite C Layton, Utah 84041
More informationMovinCool Office Pro Series. The Portable Spot Cooling Solution
MovinCool Office Pro Series The Portable Spot Cooling Solution The Office Pro 2002 American Standard Inc. All rights reserved Losing Is Not An Option With The Office Pro Series. The loss of data and equipment
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationGlossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
More informationLighting Packages. 230 VAC Fluorescent Enclosure Light:
Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for
More informationInnovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
More informationCATALOGUE 2015-2016 BIOSAFETY EQUIPMENT: UV CLEANER-RECIRCULATORS, DNA/RNA UV CLEANER BOXES, LAMINAR FLOW CABINET, MULTI-CLEANER XL
CAALOGUE 2015-2016 BIOSAFEY EQUIPMEN: UV CLEANER-RECIRCULAORS, DNA/RNA UV CLEANER BOXES, LAMINAR FLOW CABINE, MULI-CLEANER XL UVR-M and UVR-Mi, UV Cleaner Recirculators DESCRIPION UVR-M and UVR-Mi are
More information