1 Agilent Signal Generator Selection Guide
2 Introduction Agilent offers the widest selection of signal generators from baseband to 67 GHz, with frequency extensions to 1.1 THz. From basic to advanced functionality, each signal generator delivers benchmark performance in its class to address the requirements in design and manufacture of radio transceivers and their components; and applications ranging from low-frequency navigation signals, through cellular mobile radio, to millimeter wave RADAR and satellite systems. Each offers synthesized frequency accuracy and stability, excellent calibrated level accuracy, and remote programmability. Modulation capabilities vary from general-purpose AM, FM and digital I/Q to standardspecific formats such as GSM, W-CDMA, HSPA, LTE, GPS, and wireless LAN. Agilent provides signal generators in multiple form factors, including benchtop and modular PXI. This selection guide provides an overview and side-by-side comparisons to help you determine which signal generator is right for you. It is intended to supplement online selection tools available at Frequency coverage for Agilent signal generators 9 khz 100 khz 1 MHz 3 GHz 6 GHz 10 GHz 40 GHz Microwave signal generators PSG MW vector PSG MW analog MXG MW analog EXG MW analog RF signal generators Benchtop PSG RF analog MXG RF vector MXG RF analog EXG RF vector EXG RF analog N9310A RF analog Baseband products Baseband generator and channel emulator 1 Up to 160 MHz Digital interface module Up to 400 MHz (serial mode); up to 200 MHz (parallel mode) Modular PXI RF vector PXI CW PXI local oscillator 1. Additional high performance baseband arbitrary waveform generators with up to 5 GHz analog bandwidth can be found at: GHz 70 GHz
3 Product Categories Benchtop and modular PXI signal generators Benchtop signal generators are well-suited for R&D or design verification, where analysis and troubleshooting benefit from interactive analysis. Benchtop models range from RF to microwave with a broad range of capabilities so you can select which generator best suites your needs. Modular PXI signal generators are ideal for applications that require multi-channel measurement capabilities, fast measurement speed and a small footprint. They also offer scalability and flexibility to configure solutions with a shared processor, chassis and other modular instruments. The PXI vector signal generator can be used with the same software applications as bench top signal generators, providing measurement consistency and compatibility throughout the product development cycle. Vector signal generators Vector signal generators or digital signal generators have a built-in I/Q modulator to upconvert complex modulation formats such as QPSK and 64QAM. When combined with an IQ baseband generator, virtually any signal can be emulated and transmitted within the information bandwidth supported by the system. Analog signal generators Analog signal generators supply sinusoidal continuous wave (CW) signals with optional capability to add AM, FM, ΦM and pulse modulation. The maximum frequency range for analog signal generators span from RF to microwave. Most generators feature step/list sweep modes for passive device characterization or calibration. Baseband generator and channel emulator Baseband generators (BBG) output complex I/Q signals such as QPSK, and can have several modes of operation: Key Specifications Comparison... 4 Application and Software Comparison... 6 Signal Studio Software... 7 Benchtop PSG signal generators... 8 X-Series signal generators RF analog signal generator Baseband generator and interface module Modular PXI signal generators Migrating from Legacy Signal Generators Channel emulators are used to simulate the medium through which RF waves propagate. They can replicate multi-path and multi-channel fading for SISO or MIMO transceivers typically used to test the sensitivity, throughput or function of devices under test. Signal creation software Signal creation software products enable the generation of a wide range of application-specific test signals using vector signal generators. They can easily create signals to evaluate the performance of radio designs and the components that comprise them under various parametric and functional test conditions at baseband, RF and microwave frequencies. Agilent s Signal Studio software runs on a PC and embedded software runs directly on the signal generator. Waveform playback mode to play repetitive signals for component testing Real-time mode to transmit non-repeating/dynamic signals for receiver test Digital IQ input or output mode to stimulate FPGAs, DACs or ADCs 3
4 Key Speciications Comparison Vector Signal Generators Specifications PSG MW MXG RF EXG RF PXI RF Model number E8267D N5182B N5172B M9381A Performance ***** **** *** **** Frequency range (min. to max.) 100 khz to 44 GHz 9 khz to 6 GHz 9 khz to 6 GHz 1 MHz to 6 GHz Frequency switching (list mode) 9 ms 800 µs 800 µs < 10 to 240 µs Sweep mode Step, list, ramp Step, list Step, list Step, list Output power (minimum) 130 dbm 144 dbm 144 dbm 130 dbm Output power +22 dbm (at 20 GHz) +24 dbm +21 dbm +19 dbm (maximum; at 1 GHz) Level accuracy (at 1 GHz) ± 0.8 db (at 20 GHz) ± 0.6 db ± 0.6 db ± 0.4 db SSB phase noise 143 dbc/hz (at 10 khz 146 dbc/hz 122 dbc/hz 122 dbc/hz (at 1 GHz; 20 khz offset) offset) Harmonics (at 1 GHz) 55 dbc 35 dbc 35 dbc 34 dbc Non-harmonics (at 1 GHz) 88 dbc 96 dbc 72 dbc 70 dbc nominal AM rate DC to 100 khz DC to 50 khz DC to 50 khz 6.2 MHz FM deviation (maximum) 1 to 128 MHz 1 to 16 MHz 2.5 to 40 MHz 1.24 MHz PM phase deviation 1 to 800 rad 0.5 to 8 rad 1.25 to 20 rad 10 rads (maximum in normal mode) Narrow pulse width 20 ns 20 ns 20 ns 20 ns EVM (LTE) 0.8% 0.2% 0.2% 0.32%; 900 MHz ACPR (3GPP W-CDMA TM1 64 DPCH) 64 dbc (16QAM, 10 GHz) 73 dbc 73 dbc 70 dbc Internal baseband generator RF BW 80 MHz 160 MHz 120 MHz 160 MHz External I/Q modulator RF BW Up to 2 GHz Up to 200 MHz Up to 200 MHz -- Waveform playback memory 64 Msa 1024 Msa 512 Msa 1024 MSa Baseband generator mode Waveform playback and real-time IQ Benchtop Waveform playback and real-time Waveform playback and real-time Modular Waveform playback 4
5 Key Speciications Comparison Analog Signal Generators Benchtop Specifications PSG MW MXG MW EXG MW PSG RF MXG RF EXG RF RF Modular PXI local oscillator PXI CW source Model number E8257D N5183B N5173B E8663D N5181B N5171B N9310A M9302A M9380A Performance ***** **** **** **** **** *** ** ** ** Frequency range 100 khz to 9 khz to 9 khz to 100 khz to 9 khz to 6 GHz 9 khz to 6 GHz 9 khz to 3 GHz 3 GHz to 10 GHz 1 MHz to 6 GHz (min. to max.) 70 GHz 40 GHz 40 GHz 9 GHz Frequency switching 9 ms 600 µs 600 µs 9 ms 800 µs 800 µs 10 ms 500 µs 5 ms (list mode) Sweep mode list, step, ramp list, step list, step list, step, ramp list, step list, step list, step NA NA Output power 135 dbm 130 dbm 130 dbm 135 dbm 144 dbm 144 dbm 127 dbm NA 130 dbm (minimun) Output power +26 dbm +20 dbm +20 dbm +23 dbm +24 dbm +21 dbm +13 dbm +16 dbm +19 dbm (at 1 GHz) (at 20 GHz) (at 20 GHz) (at 20 GHz) Level accuracy ± 0.8 db ± 0.7 db ± 0.7 db ± 0.6 db ± 0.6 db ± 0.6 db ± 1.0 db ± 2 db ± 0.4 db (at 20 GHz) (at 10 GHz) (at 10 GHz) SSB phase noise 126 dbc/hz 124 dbc/hz 101 dbc/hz 143 dbc/hz 146 dbc/hz 122 dbc/hz 95 dbc/hz 115 dbc/hz 122 dbc/hz (1 GHz, 20 khz offset) (at 10 GHz, 10 khz offset) (at 10 GHz) (at 10 GHz) (at 10 khz offset) (10 GHz, 10 khz offset) Harmonics (at 1 GHz) 55 dbc 55 dbc 55 dbc 55 dbc 35 dbc 35 dbc 30 dbc 20 dbc 29 dbc (at 10 GHz) (at 10 GHz) Non-harmonics 88 dbc 100 dbc 72 dbc 88 dbc 96 dbc 72 dbc 50 dbc 70 dbc 70 dbc (at 1 GHz) AM rate DC to 100 khz DC to 100 khz DC to 100 khz DC to 100 khz DC to 50 khz DC to 50 khz 20 Hz to 20 khz NA NA FM deviation 1 to 128 MHz 1 to 128 MHz 2.5 to 320 MHz 1 to 16 MHz 1 to 16 MHz 2.5 to 40 MHz 100 khz NA NA (maximum) PM phase deviation 1 to 1280 rad 0.5 to 64 rad 1.25 to 160 rad 1 to 160 rad 0.5 to 8 rad 1.25 to 20 rad 10 rad NA NA (maximum, in normal mode) Narrow pulse width 20 ns 20 ns 20 ns 20 ns 20 ns 20 ns 100 µs NA NA 5
6 Applications, Core Capabilities and Software Comparison Applications and signal creation software Instrument embedded capabilities PSG MW MXG and EXG RF PXI RF PSG MW MXG and EXG MW Benchtop MXG and EXG RF PSG RF N9310 RF PXB vector analog baseband USB power meter Step/list sweep Ramp sweep AM, FM, PM, pulse LF function generator Real-time custom modulation (PSK, QAM, FSK) Phase noise impairments Multitone, NPR Noise (AWGN) Pulse Train SystemVue, MATLAB Real-time fading Signal Studio software Cellular communications LTE & LTE-Advanced FDD/TDD, W-CDMA/HSPA+, cdma2000, 1xEV-DO, GSM/EDGE/Evo, TD-SCDMA Wireless networking WLAN a/b/g/j/p/n/ac, Mobile WiMAX, Bluetooth Fixed WiMAX Audio/video broadcast DVB-T/H/T2/S/S2, DVB-C (J.83 Annex A/C), J.83 Annex B (DOCSIS DS), ISDB-T/Tmm, ATSC, ATCS-M/H, DTMB (CTTB), CMMB T-DMB, DAB/DAB+/DMB-audio, FM stereo with RDS/RBDS Detection, positioning, tracking, & navigation Pulse building Multitone distortion, NPR GPS, GLONASS, Galileo, Beidou, SBAS, QZSS Wideband waveform center software Wireless HD, WiGig, ad Benchtop Modular 6
7 Signal Studio Software Simplify signal creation Connect your vector source to Signal Studio and simplify signal creation. Whether you are working on a single radio format or integrating multiple formats into a single device, easy access to the right test signals streamlines validation and helps ensure interoperability. Accelerate your work with Agilent Signal Studio software, a flexible suite of signal-creation tools that reduces the time you spend on signal simulation. Its performance-optimized reference signals, validated by Agilent, enhance the characterization and verification of your devices. Configure Signal Studio to match your requirements: Choose basic or advanced levels of capability with scalable option structure Select the license type that fits your specific use case and budget, including fixed, transportable, and 5- or 50-pack waveforms Connect to a wide range of Agilent instruments Runs on a PC Leverage and customize built-in signals with flexible signal generation, additive impairments, graphs, convenient connectivity and automation, and embedded and online documentation. Control your vector signal generator directly from the software GUI and/or from the instrument front panel. General purpose Jitter injection Multitone, NPR Waveform download utility Cellular communications LTE & LTE-Advanced FDD/TDD, W-CDMA/HSPA+, cdma2000, 1xEV-DO, GSM/EDGE/ Evo, TD-SCDMA Wireless connectivity WLAN a/b/g/j/p/n/ac/ad Mobile WiMAX, Fixed WiMAX Bluetooth Audio/video broadcasting ATSC, CMMB, DTMB, DVB, S-DMB, T-DMB ISDB-T, J.83 Annex A/B/C DAB, DAB+, DMB DOCSIS FM Stereo, RDS/RBDS Detection, positioning, tracking, and navigation Pulse building GPS, GLONASS, Galileo, Beidou, SBAS, QZSS, Radar Free Trial License Free 30-day trials of Signal Studio software are available to evaluate the user interface and generate signals. Redeem a trial license online at 7
8 PSG Signal Generators The PSG is the industry's most trusted microwave signal generator, with thousands of units deployed in hundreds of programs around the world. With metrology-grade performance and evolving capabilities across RF and microwave frequencies, it continues to enable new designs that stay ahead of emerging threats. PSG microwave signal generator E8267D vector Test advanced receivers with realistic wideband radar, EW and SATCOM waveforms up to 44 GHz Flexible integrated 80 MHz AWG, real-time and baseband generator to simulate cellular, wireless, GPS and custom communications Exercise advanced EW, radar and satellite systems with Signal Studio, a vector PSG and a wideband AWG such as the Agilent M8190A for up to 2 GHz bandwidth Test phased-array systems and direction-finding receivers with multiple phase-coherent signals generated by linking up to 16 vector PSGs PSG microwave signal generator E8257D analog Meet test system needs across a wide range: 20, 31.8, 40, 50 and 67 GHz models available (add frequency extender modules to cover up to 1.1 THz) Test high-power devices and overcome test system losses with options capable of generating more than 1 W (+30 dbm) of output power Address the demanding needs of Doppler radar, ADC and receiver-blocking tests with the PSG's extremely low phase noise: -91 dbc/hz at 100 Hz offset and -126 dbc/hz at 10 khz offset (10 GHz) Test your DUT with the highest quality signals: the PSG combines metrology-grade frequency and level accuracy with excellent distortion and spurious characteristics Key specifications E8267D MW vector E8257D MW analog Frequency range (min. to max.) 100 khz to 44 GHz 100 khz to 70 GHz Frequency switching 9 ms 9 ms Output power (at 20 GHz) +22 dbm +26 dbm Level accuracy ± 0.6 db ± 0.6 db SSB phase noise (10 GHz; 10 khz offset) 126 dbc/hz 126 dbc/hz Harmonics 55 dbc 55 dbc EVM (QPSK) 0.8% N/A ACPR (16 QAM) 64 dbc N/A Internal baseband generator RF BW 80 MHz N/A 8
9 PSG Signal Generator Millimeter Wave Accessories for the PSG Signal Generator Millimeter wave sources are essential instruments for developing almost all millimeter-wave systems. Easily extend the frequency range of your E8257D or E8267D PSG signal generators with these multiplier modules from select partners. PSG RF signal generator E8663D analog The E8663D PSG RF analog signal generator provides the industry s lowest phase noise in a commercially-available signal generator. With optional analog modulation (AM, FM, ØM and pulse) capability, superior level accuracy and high output power, the E8663D is the right choice for demanding applications such as radar system development, satellite communications evaluation, or when a very low noise local oscillator or reference signal is needed. Built on the outstanding legacy of the 8663A, the E8663D delivers improved performance and is fully code compatible with its predecessor for seamless upgrades to existing test systems. Enhanced narrow pulse modulation and extended support life are optionally available. Millimeter-wave source modules from OML, Inc. The E8257DSxx-Series of external, high-power, frequency banded millimeter-wave source modules provide synthesized frequency performance, millimeter-wave test signals for waveguide bands from 50 to 500 GHz. Signal generator frequency extension modules from VDI, Inc. The E8257DVxx-Series of signal generator frequency extension modules provide high power, synthesized frequency performance millimeter-wave test signals for waveguide bands from 50 GHz to 1.1 THz. Key specifications Frequency range (min. to max.) Frequency switching Output power Level accuracy SSB phase noise (1 GHz; 10 khz offset) Harmonics 100 khz to 9 GHz 9 ms +23 dbm ± 0.6 db 143 dbc/hz 55 dbc 9
10 X-Series Signal Generators Crafted to create signals capable of testing your very best devices and designs, the X-Series signal generators offer industry-leading performance and low cost of ownership. A proven, scalable platform combined with cost-effective calibration and internal diagnostics allows you to buy the capabilities you need today and easily upgrade to meet future requirements. N5183B analog MXG microwave signal generator The MXG is the pure and precise alternative to the analog PSG, with advantages in size and speed. It delivers the performance you need to perform module- and system-level testing fast in only two rack units. Meet test system needs up to 13, 20, 31.8, or 40 GHz Address demanding tests of radar modules and systems with best-in-class phase noise of 124 dbc/hz (10 khz offset) with 75 dbc spurious (at 10 GHz) Save space and maintain test rigor with near-psg performance levels in just two rack units Accelerate your calibration process with best-in-class switching speed of less than 600 μs N5173B analog EXG microwave signal generator The EXG is the cost-effective choice when you need to balance budget and performance. In just two rack units, it provides the essential signals that address parametric testing of broadband filters, amplifiers, receivers, and more. Perform basic LO upconversion or CW blocking with lowcost coverage to 13, 20, 31.8, or 40 GHz Characterize broadband microwave components such as filters and amplifiers with the best combination of output power (+20 dbm at 20 GHz), low harmonics ( 55 dbc), and full step attenuation Use as a high-stability system reference with standard high-performance OCXO at an aging rate of less than ± 5 x parts per day Shrink your test stand with optional integrated multifunction generator and USB power sensor interface Key specifications MXG microwave analog N5183B EXG microwave analog N5173B Frequency range (min. to max.) 9 Hz to 40 GHz 9 Hz to 40 GHz Frequency switching 600 us 600 us Output power (20 GHz) +20 dbm + 20 dbm Level accuracy (10 GHz) ± 0.7 db ± 0.7 db SSB phase noise (10 GHz) 124 dbc/hz 101 dbc/hz Harmonics (10 GHz) 55 dbc 55 dbc 10
11 X-Series Signal Generators MXG RF signal generators N5182B vector and N5181B analog To help you reach better performance, the MXG X-Series vector and analog signal generators are fine-tuned to be your golden transmitter in R&D. Whether you re pushing for a linear RF chain or an optimized link budget, the MXG delivers what you need: phase noise, ACPR, channel coding, and much more. Reveal the true performance of your devices and test your designs within and beyond their limits with the MXG. Test radar receiver sensitivity or characterize ADC with industry-leading phase noise Characterize nonlinear PA behavior with industry-leading ACPR and output power Test ac with < 0.4% EVM, or characterize multicarrier PAs with < ± 0.2 db flatness across 160 MHz bandwidth Go beyond standard application requirements with sophisticated real-time and waveform-based Signal Studio software EXG RF signal generators N5172B vector and N5171B analog To help you achieve faster throughput and greater uptime, the cost-effective EXG X-Series signal generators are optimized for manufacturing test. With analog and vector models, the EXG provides the signals you ll need for basic parameter testing of components and functional verification of receivers. Get just enough test at the right price with the EXG. Maximize test margins on the production line with industryleading ACPR Maximize throughput with < 800 µs simultaneous switching of frequency, power and waveform type Enable rapid, accurate tests using Signal Studio s predefined, standards-based waveforms Shrink your test stand with two rack-unit height and integrated multi-function generator and USB power sensor interface Key specifications MXG RF vector N5182B MXG RF analog N5181B EXG RF vector N5172B EXG RF analog N5171B Frequency range (min. to max.) 9 khz to 6 GHz 9 khz to 6 GHz 9 khz to 6 GHz 9 khz to 6 GHz Frequency switching 800 µs 800 µs 800 µs 800 µs Output power +24 dbm +24 dbm +21 dbm +21 dbm Level accuracy ± 0.6 db ± 0.6 db ± 0.6 db ± 0.6 db SSB phase noise (1 GHz; 20 khz offset) 146 dbc/hz 146 dbc/hz 122 dbc/hz 122 dbc/hz Harmonics 35 dbc 35 dbc 35 dbc 35 dbc EVM (LTE) 0.2% N/A 0.2% N/A ACPR (3GPP W-CDMA TM1 64 DPCH) 73 dbc N/A 73 dbc N/A Internal baseband generator RF BW 160 MHz N/A 120 MHz N/A 11
12 RF Analog Signal Generator RF signal generator N9310A analog The N9310A is a general-purpose RF signal generator covering a frequency range from 9 khz to 3 GHz. With a low price, reliable performance, and multiple built-in functions, it s well-suited for manufacturing, education, and service maintenance. While you may occasionally need a full-function and highperformance signal generator, many times you only need a simple continuous wave (CW) source. For this application, the N9310A RF signal generator is ideal. When you need the solution that provides just enough functionality at the lowest price select the N9310A RF signal generator. Optimized for low-cost consumer electronics manufacturing test, education and service and repair Optional I/Q modulator 40 MHz bandwidth (ext. I/Q inputs only) USB interface, with flash memory support Key specifications Frequency range (min. to max.) Frequency switching Output power Level accuracy SSB phase noise (1 GHz; 20 khz offset) Harmonics 9 khz to 3 GHz 10 ms +13 dbm ± 1.0 db 95 dbc/hz 30 dbc 12
13 Baseband Generator and Interface Module PXB baseband generator and channel emulator N5106A The PXB lets you customize test cases and validate designs under real-world conditions with the broadest range of test parameters. Create fully-parameterized signals for established and evolving standards with Agilent Signal Studio. In addition, the PXB lets you model the signal-propagation environment with fully-parameterized, real-time channel emulation (fading). With the largest playback memory available, you can run longer test sequences to better approximate real-world signals. You can also capture signals up to 512 Msa from your own device for post processing. With less instrumentation to manage, the PXB simplifies test setup. You need only one box for multi-format baseband generation, real-time fading and signal capture. With it, you can construct over 20 configurations to meet your test needs. These configurations, along with external instrument connections, can be redefined in seconds using the PXB user interface. Up to 160 MHz modulation and signal capture bandwidth 512 Msa playback and signal capture memory per channel Up to six BBGs and 16 faders for interference, diversity and MIMO test Digital signal interface module N5102A The N5102A digital signal interface module provides fast and flexible digital inputs and outputs for the MXG and EXG X-Series vector signal generators, E8267D PSG vector signal generator and N5106A PXB baseband generator and channel emulator. In output mode, you can deliver realistic complex-modulated signals such as LTE, HSPA, W-CDMA, GPS, WLAN, digital video, custom pulses and many others directly to your digital devices and subsystems. In the input mode, the interface module ports your digital input to the signal generator's baseband system, providing a quick and easy way of upconverting to calibrated analog IF, RF or µw frequencies. In both operating modes, the interface module adapts to your device with the logic type, data format, clock features, and signaling you require. With its 3-meter extension cable and a selection of connector types, the interface module connects easily to your device, in most cases eliminating the need for custom fixtures. Up to 400 MHz in serial mode, 200 MHz in parallel mode Provision for internal, external, or device clocking Independent data input and output rates; adjustable clock phase and skew
14 PXI Signal Generators PXIe vector signal generator M9381A The PXI vector signal generator provides a combination of speed, performance and multi-channel capability needed for automated test environments. Measurement consistency with bench top instruments is enabled through a suite of common software applications. Fast switching times -- < 240 µs from its programming interface and < 10 µs in list mode using an exclusive baseband tuning technology innovation for switching power and frequency Better linearity, repeatability and resolution further reduce the test time +18 dbm specified output power across the frequency range, excellent modulation quality -- particularly at high output power levels Up to 160 MHz modulation bandwidth (± 0.3 db flatness) PXIe CW source M9380A With high-power levels and accurate measurements, the Agilent M9380A CW source is a configuration without the digital vector modulator module. The Agilent M9018A all-hybrid 18- slot PXIe chassis and M9036A PXIe embedded controller are ideal to complete both configurations. Agilent Quality and Support in PXI Keep measurement quality while reducing your cost of ownership with Agilent s unique RF modular calibration and fast core exchange strategy. Agilent PXI signal generators are factory calibrated, shipped with ISO-9002, NIST traceable Cal certificate, and include a 3-year warranty. Key specifications M9381A PXIe vector M9380A PXIe CW source Frequency range (min. to max.) 1 MHz to 6 GHz 1 MHz to 6 GHz Frequency switching < 10 to 240 µs 5 ms Output power (at 1 GHz) +19 dbm +19 dbm Level accuracy ± 0.4 to 1 db ± 0.4 to 1 db SSB phase noise (1 GHz; 20 khz offset) 122 dbc/hz 122 dbc/hz Harmonics < 34 dbc < 29 dbc EVM (LTE) 0.32% N/A ACPR (3GPP W-CDMA TM1 64 DPCH) 70 dbc N/A Internal baseband generator RF BW 160 MHz N/A 14
15 PXI Signal Generators PXI local oscillator M9302A The M9302A PXI local oscillator (LO) is optimized for fast settling time to allow for fast frequency down conversion in aerospace and defense applications, such as radar and wideband signal capture, and in wireless communications applications. The M9302A is a two-slot 3U PXI VCO-based 3 GHz to 10 GHz LO. The fast switching time and low phase noise of this LO make it an ideal component of a microwave vector signal analyzer. When integrated in the Agilent M9392A PXI vector signal analyzer, then combined with VSA software, the M9302A provides a complete signal analyzer solution enabling analysis of communications, radar and avionics signals to 26.5 GHz in a modular open-system standard. ± 0.5 ppm frequency temperature stability (0 to 50 C) 0.1 Hz tuning resolution PXI 2-slot 3U Key specifications Frequency range (min. to max.) Frequency switching Output power Level accuracy SSB phase noise (10 GHz; 10 khz offset) Harmonics 3 to 10 GHz 1 ms +16 dbm ± 2 db 115 dbc/hz 20 dbc 15
16 Migrating from Legacy Signal Generators Carefully planned instrument migration and modernization can maximize your test-system efficiency, performance, and readiness, while minimizing risk and potential disruptions, keeping you at the leading edge in the competitive marketplace. The Agilent PSG and X-Series signal generators are designed as evolutionary replacements to their in-class predecessors. Take advantage of their performance, flexibility, speed and modern connectivity in replacing legacy Agilent signal generators. PSG MW vector E8267D 100 khz to 44 GHz PSG MW analog E8257D 100 khz to 70 GHz MXG/EXG MW analog N5183B/N5173B 9 khz to 40 GHz PSG RF analog E8663D 100 khz to 9 GHz MXG RF vector N5182B 9 khz to 6 GHz MXG RF analog N5181B 9 khz to 6 GHz EXG RF vector N5172B 9 khz to 6 GHz EXG RF analog N5171B 9 khz to 6 GHz 8780A E2500B 8340A/B 8341A/B 83620A/B 83622A/B 83623B/L 83624A/B 83630B/L 83640B/L 83650B/L 83711A/B 83712A/B 83731A/B 83732A/B 83751A/B 83752A/B N5183A 8672A 8763A/B/C/D 8340A/B 8341A/B 83620A/B 83622A/B 83623B/L 83624A/B 83630B/L 83640B/L 83711A/B 83712A/B 83731A/B 83732A/B 83751A/B 83752A/B 8662A/B 8643A 8644B 8645A 8664A 8665A/B E4438C ESG-DP Series E4434B E4435B E4436B E4437B E4428C ESG-AP Series E4423B E4424B E4425B E4426B 8672A 8763A/B/C/D 8662A/B 8643A 8644B 8645A 8664A 8665A/B N5182A ESG-D Series E4430B E4431B E4432B E4433B N5181A ESG-A Series E4400B E4420B E4421B E4422B 8647A 8648A/B/C/D 8656B 8657A/B/D/J Migrate to the X-Series RF Signal Generators Migrate to Microwave Signal Generators 16
17 myagilent A personalized view into the information most relevant to you. For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. PCI extensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty Beyond product specification, changing the ownership experience. Agilent is the only test and measurement company that offers three-year warranty on all instruments, worldwide Agilent Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management System Agilent Channel Partners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. Americas Canada Brazil Mexico United States Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries Europe & Middle East Belgium Denmark Finland France Germany Ireland Israel Italy Netherlands Spain Sweden United Kingdom (877) (11) (800) (421) (65) (0) (0) * *0.125 /minute 49 (0) / (0) (91) (0) cdma2000 is a registered certification mark of the Telecommunications Industry Association. Used under license. WiMAX is a trademark of the WiMAX Forum. Bluetooth and the Bluetooth logos are trademarks owned by Bluetooth SIG, Inc, U.S.A. and licensed to Agilent Technologies, Inc. For other unlisted countries: (BP ) Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc Published in USA, April 16, EN
X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software
X-Series Signal Analysis Future-ready instruments Consistent measurement framework Broadest set of applications and software Arrive Ahead with X-Series We can t predict the future, but Agilent can help
What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?
What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope? Application Note In the past, deciding between an equivalent time sampling oscilloscope and a real
How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer
How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer Application Note Introduction In a pulsed radar system, one of the key transmitter-side components
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors Demo Guide Introduction This demonstration guide helps you to get familiar with the basic setup and coniguration requirements
U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes
U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes Data Sheet This application is available in the following license variations Order N7248A for user-installed license
Agilent E363xA Series Programmable DC Power Supplies. Data Sheet
Agilent E363xA Series Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and triple output 80 W to 200 W output power Dual range output Low noise and excellent regulation
Real-Time Spectrum Analysis for Troubleshooting 802.11n/ac WLAN Devices
Real-Time Spectrum Analysis for Troubleshooting 802.11n/ac WLAN Devices Application Brief 802.11 WLAN devices operate in the license-exempt 2.4 GHz ISM and 5 GHz UNII bands, where they must share spectrum
802.11ac Power Measurement and Timing Analysis
802.11ac Power Measurement and Timing Analysis Using the 8990B Peak Power Analyzer Application Note Introduction There are a number of challenges to anticipate when testing WLAN 802.11ac [1] power amplifier
Agilent E5063A ENA Series Network Analyzer
Agilent E5063A ENA Series Network Analyzer 100 khz to 4.5/ 8.5/18 GHz Configuration Guide Ordering Guide The following steps will guide you through configuring your E5063A. Standard furnished item Description
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors GSM Timeslot Burst Power Measurement Product Note Table of Content Introduction 2 Measuring GSM Timeslot 4 Signal Overview of Agilent U2000 5 Series USB Power Sensors
Agilent E6832A W-CDMA Calibration Application
Agilent E6832A W-CDMA Calibration Application For the E6601A Wireless Communications Test Set Data Sheet The next generation of mobile phone manufacturing test. E6601A is the newest test set from Agilent
N6171A MATLAB Data Analysis Software for Agilent Instruments
N6171A MATLAB Data Analysis Software for Agilent Instruments Technical Overview MATLAB is available directly from Agilent or its authorized sales partners with your instrument purchase Use MATLAB to create
Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide
Keysight M9485A PXIe Multiport Vector Network Analyzer Configuration Guide 02 Keysight M9485A PXIe Multiport Vector Network Analyzer - Configuration Guide Ordering Guide The following steps will guide
Evaluating Oscilloscope Bandwidths for Your Application
Evaluating Oscilloscope Bandwidths for Your Application Application Note Table of Contents Introduction....1 Defining Oscilloscope Bandwidth.....2 Required Bandwidth for Digital Applications...4 Digital
Agenda. Agilent GPS Receiver Test Solutions. GPS technology concepts. Basic tests required for GPS receiver verification Test solutions
Agenda GPS technology concepts GPS and GNSS overview Assisted GPS (A-GPS) Basic tests required for GPS receiver verification Test solutions Signal creation for GPS receiver test A-GPS test systems Agilent
Make Better RMS Measurements with Your DMM
Make Better RMS Measurements with Your DMM Application Note Introduction If you use a digital multimeter (DMM) for AC voltage measurements, it is important to know if your meter is giving you peak value,
Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note
Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments Application Note Table of Contents Introduction 2 U2000 Series USB Power 3 Sensor s Compatibility with Agilent Instruments
Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator
Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator Application Note 1 Summary Introduction As a part of the certification
The Next Generation in Automated Oscilloscope Test
The Next Generation in Automated Oscilloscope Test Spanning 100 MHz to 13 GHz, and varying in height from 1U to 8U, Agilent s family of LXI compliant oscilloscopes can accommodate virtually any automated
Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz
Agilent E5061B Network Analyzer 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz E5061B responds to various measurement needs, from LF to RF The Agilent E5061B is a member of the industry standard ENA Series network
Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance
Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance Using a Keysight High-Frequency USB Power Sensor Application Note 1.0 Introduction Satellite communication systems are driven
Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz
Agilent E5063A ENA Series Network Analyzer 100 khz to 4.5/ 8.5/18 GHz The Best Balance Between Price and Performance The E5063A is a low cost network analyzer for simple passive component testing up to
DDR Memory Overview, Development Cycle, and Challenges
DDR Memory Overview, Development Cycle, and Challenges Tutorial DDR Overview Memory is everywhere not just in servers, workstations and desktops, but also embedded in consumer electronics, automobiles
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors Single/Multi-Channel Power Measurement Simple Setup Affordable Demo Guide Table of Contents Introduction 2 The Agilent N1918A Power 3 Analysis Manager Demonstration
Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview
Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview The flexible GSM/EDGE base station test solution with a 3G future... Designed for manufacturing
Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software
Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software Technical Brief Introduction The MSO70000 Series Mixed Oscilloscope, when coupled with SignalVu Spectrum
Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note
Agilent Compatibility of USB Power Sensors with Agilent Instruments Application Note Use USB Power Sensors as an Agilent Instruments Accessory Table of Contents Agilent USB Power Sensors 2 USB Power Sensor
N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes
N546A and N547A USB Compliance Test Software for Infiniium Oscilloscopes Data Sheet The N546A USB compliance test software for Infiniium oscilloscopes gives you a fast and reliable way to verify USB electrical
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors Configuration Guide U2000 Series USB Power Sensors U2000A (10 MHz to 18 GHz) U2001A (10 MHz to 6 GHz) U2002A (50 MHz to 24 GHz) U2004A (9 khz to 6 GHz) U2000H (10
Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes
Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes Data Sheet Enhance your InfiniiVision or Infiniium oscilloscope with the analysis power of MATLAB software Develop custom analysis
Agilent FieldFox Remote Viewer
Agilent FieldFox Remote Viewer Application Brief Agilent Remote Viewer setup instructions The FieldFox remove viewer is a FREE ios application which allows you to view an Agilent FieldFox analyzer from
Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network
Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network Application Brief Test Challenges: Designing heating and air conditioning (HVAC) systems Collecting data on a remotely located
Variable Frequency Drive Troubleshooting with U1610A/U1620A
Variable Frequency Drive Troubleshooting with U1610A/U1620A Application Note Electric motors form the backbone of most industrial and manufacturing environments. Variable frequency drives (VFDs) (also
Digital Audio Broadcasting Receiver Testing Solutions
Digital Audio Broadcasting Receiver Testing Solutions Self-Guided Demonstration Using Signal Studio software and PXB, MXG/ESG signal generators for digital audio broadcasting receiver test Featured Products:
Agilent 87421A/87422A Power Supply
Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration
Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet
Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet Use BenchVue software to: Visualize multiple measurements simultaneously Easily capture data, screen shots and
Keysight N9320B RF Spectrum Analyzer
Keysight N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet 02 Keysight N9320B RF Spectrum Analyzer - Data Sheet Definitions and Conditions Specifications describe the performance of parameters covered
How To Use A Sound Card With A Subsonic Sound Card
!"## $#!%!"# &"#' ( "#' )*! #+ #,# "##!$ -+./0 1" 1! 2"# # -&1!"#" (2345-&1 #$6.7 -&89$## ' 6! #* #!"#" +" 1##6$ "#+# #-& :1# # $ #$#;1)+#1#+
Keysight Technologies 8 Hints for Better Spectrum Analysis. Application Note
Keysight Technologies 8 Hints for Better Spectrum Analysis Application Note The Spectrum Analyzer The spectrum analyzer, like an oscilloscope, is a basic tool used for observing signals. Where the oscilloscope
Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note
Keysight Technologies Using Fine Resolution to Improve Thermal Images Application Note Introduction Digital imaging opened up new possibilities and has been very much part of our lives since social media
Addressing the Challenges of Deploying Single Frequency Networks DVB-T & DVB-T2. Application Note
Addressing the Challenges of Deploying Single Frequency Networks DVB-T & DVB-T2 Application Note Contents Introduction... 3 SFN Echo Scenarios... 4 Post-echo scenario... 4 Pre-echo scenario... 4 Pre-echoes
Keysight Technologies N9320B RF Spectrum Analyzer
Keysight Technologies N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has
Agilent 4338B Milliohm Meter
Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top
Keysight Technologies Solutions for WLAN 802.11ac Manufacturing Test
Keysight Technologies Solutions for WLAN 802.11ac Manufacturing Test Application Note Testing 802.11ac Client and Infrastructure Devices Using a Fast, Flexible and Cost-Effective Calibration and Non-Signaling
Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range. Application Note
Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range Application Note Introduction Achieving the highest possible network analyzer dynamic range is extremely important when
Wireless Connectivity Testing
N4010A Test Solutions Flexible verification solutions for developers, integrators, and manufacturers working with Bluetooth, Bluetooth Enhanced Data Rate (EDR), ZigBee, Wireless LAN (WLAN), 802.11 a/b/g,
PXI. www.aeroflex.com. GSM/EDGE Measurement Suite
PXI GSM/EDGE Measurement Suite The GSM/EDGE measurement suite is a collection of software tools for use with Aeroflex PXI 3000 Series RF modular instruments for characterising the performance of GSM/HSCSD/GPRS
Keysight N6854A Geolocation System. Configuration Guide
Keysight N6854A Geolocation System Configuration Guide 02 Keysight N6854A Geolocation System - Configuration Guide This guide will help you configure a geolocation system that meets your needs and includes
Strategies in Software Defined RF and Wireless Communications Test. Srini Badri Business Development Manager National Instruments
Strategies in Software Defined RF and Wireless Communications Test Srini Badri Business Development Manager National Instruments Wireless Technology Driving Applications Emergence of the Smart Phone Growth
Agilent 8762/3/4A,B,C Coaxial Switches
Agilent 8762/3/4A,B,C Coaxial Switches Technical Overview High performance switches for microwave and RF instrumentation and systems Agilent Technologies offers a ver satile line of multiport coaxial switches.
Agilent P940xA/C Solid State PIN Diode Switches
Agilent P940xA/C Solid State PIN Diode Switches Operating and Service Manual Agilent Technologies Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by any
APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer
APSYN420A/B Specification 1.24 0.65-20.0 GHz Low Phase Noise Synthesizer 1 Introduction The APSYN420 is a wideband low phase-noise synthesizer operating from 0.65 to 20 GHz. The nominal output power is
Keysight Technologies Test Case Manager N7649B
Keysight Technologies Test Case Manager N7649B Technical Overview Predefined standard-based conformance test setups save time and give you confidence that your measurements are standard-compliant Generate
Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet
Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price Data Sheet Features 120000 counts resolution 16 built-in measurement functions including temperature and
Propsim enabled Aerospace, Satellite and Airborne Radio System Testing
www.anite.com Propsim enabled Aerospace, Satellite and Airborne Radio System Testing Anite is now part of Keysight Technologies Realistic and repeatable real-time radio channel emulation solutions for
National Instruments MIMO Technology Demonstration
National Instruments MIMO Technology Demonstration National Instruments UK & Ireland 1 National Instruments National Instruments (http://www.ni.com) is transforming the way engineers and scientists design,
PXI and AXIe Modular Instrumentation
PXI and AXIe Modular Instrumentation M9018A PXIe Chassis M9502A AXIe Chassis M9505A AXIe Chassis Tested Computer List Technical Note DISCOVER the Alternatives...... Agilent MODULAR Products OVERVIEW This
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise
PXI and AXIe Modular Instrumentation
PXI and AXIe Modular Instrumentation M9018A PXIe Chassis M9502A AXIe Chassis M9505A AXIe Chassis U4002A Digital Test Console Chassis Tested Computer List Technical Note DISCOVER the Alternatives......
PXI Modules. 3025 Digital RF Signal Generator. www.aeroflex.com
PXI Modules 3025 Digital RF Signal Generator Fully featured PXI digital RF signal generator module for applications in communications system test Frequency range 86 MHz to 6 GHz Level range -120 to + 5
Agilent Test Solutions for Multiport and Balanced Devices
Agilent Test Solutions for Multiport and Balanced Devices Duplexer test solutions 8753ES option H39/006 During design and final alignment of duplexers, it is often necessary to see both the transmit-antenna
PCI Express Probes for Agilent E2960B PCI Express Analysis Systems
PCI Express for Agilent E2960B PCI Express Analysis Systems Version: 1.2 Superior Signal Probing options to address diverse designs and form factors As an industry leader in the innovation of non-intrusive,
Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note
Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox Application Note Introduction Of all the signal engines in the N7509A, the most complex is the multi-tone engine. This application
Measuring ACLR Performance in LTE Transmitters. Application Note
Measuring ACLR Performance in LTE Transmitters Application Note Introduction As wireless service providers push for more bandwidth to deliver IP services to more users, LTE has emerged as a next-generation
FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment
FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS drm TesT equipment dt230 playback of drm signals recording of drm signals channel simulation receiver performance analysis real-time modulation Architecture
Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview
Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview Reduce your cost of ownership by minimizing time to calibrate and
GSM/EDGE Output RF Spectrum on the V93000 Joe Kelly and Max Seminario, Verigy
GSM/EDGE Output RF Spectrum on the V93000 Joe Kelly and Max Seminario, Verigy Introduction A key transmitter measurement for GSM and EDGE is the Output RF Spectrum, or ORFS. The basis of this measurement
Agilent E3830 Series Wide-bandwidth Signal Analyzer Custom Systems 100 MHz Bandwidth Microwave Vector Signal Analysis
Agilent E3830 Series Wide-bandwidth Signal Analyzer Custom Systems 100 MHz Bandwidth Microwave Vector Signal Analysis The measurement challenge 2 Many advanced microwave applications involve complex wideband
Propagation Channel Emulator ECP_V3
Navigation simulators Propagation Channel Emulator ECP_V3 1 Product Description The ECP (Propagation Channel Emulator V3) synthesizes the principal phenomena of propagation occurring on RF signal links
Agilent Television Power Consumption Testing. Application Note
Agilent Television Power Consumption Testing Application Note Introduction Today, there are many types of televisions (TVs) on the market: the cathode ray tube (CRT) TV, liquid crystal display (LCD) TV,
Understanding the Effect of Uncorrelated Phase Noise on Multi-channel RF Vector Signal Generators and Analysers
Understanding the Effect of Uncorrelated Phase Noise on Multi-channel RF Vector Signal Generators and Analysers David A. Hall, Product Marketing Manager Andy Hinde, RF Systems Engineer Introduction With
Agilent E5100A Network Analyzer
Agilent E5100A Network Analyzer Data Sheet These specifications are the performance standards or limits against which the instrument is tested. When shipped from the factory, the E5100A meets the specifications
Agilent 4339B/4349B High Resistance Meters
Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance
Technical Overview with Self-Guided Demonstration
Agilent PSA Series Spectrum Analyzers External Source Control Measurement Personality, Option 215 Technical Overview with Self-Guided Demonstration Expand your PSA Series from spectrum analysis to scaler
RF Measurements Using a Modular Digitizer
RF Measurements Using a Modular Digitizer Modern modular digitizers, like the Spectrum M4i series PCIe digitizers, offer greater bandwidth and higher resolution at any given bandwidth than ever before.
Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers
Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers N4690 Series, 2-port Microwave ECal 85090 Series, 2-port RF ECal N4430 Series, 4-port ECal Technical Overview Control ECal directly
Propsim enabled Mobile Ad-hoc Network Testing
www.anite.com Propsim enabled Mobile Ad-hoc Network Testing Anite is now part of Keysight Technologies Lab-based, end-to-end performance testing of systems using Propsim MANET channel emulation A Mobile
TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits
TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet TCA-N TekConnect-to-N DC to 11 GHz (Instrument Dependent) 50 Ω Input (Only) TCA-SMA TekConnect-to-SMA DC to 18 GHz (Instrument Dependent)
C2K-ATS Minimum Performance Test Option
spirent C2K-ATS Spirent s C2K-ATS is the leading automated solution for testing wireless 1X and EV-DO Rev. 0/Rev. A/Rev. B handsets and terminal devices. C2K-ATS complete automation, ease of use and accuracy
Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at www.agilent.com/find/service
Agilent Infoline Web Services Quick Reference Guide Scan and use your phone to go to Infoline at www.agilent.com/find/service One location for all information This quick reference guide reviews the powerful
Agilent 8753ET/8753ES Network Analyzers
Agilent 8753ET/8753ES Network Analyzers 8753ET, 300 khz to 3 or 6 GHz 8753ES, 30 khz to 3 or 6 GHz Configuration Guide System configuration summary The following summary lists the main components required
R&S FSW signal and spectrum analyzer: best in class now up to 50 GHz
R&S FSW signal and spectrum analyzer: best in class now up to 50 GHz The new R&S FSW 43 and R&S FSW 50 signal and spectrum analyzers make the outstanding features of the R&S FSW family available now also
Optimizing IP3 and ACPR Measurements
Optimizing IP3 and ACPR Measurements Table of Contents 1. Overview... 2 2. Theory of Intermodulation Distortion... 2 3. Optimizing IP3 Measurements... 4 4. Theory of Adjacent Channel Power Ratio... 9 5.
Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer
Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer Application Note Introduction The RF power amplifier is a key component used in a wide variety of industries such as wireless
81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing
81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing Application Note Introduction Industry sectors including computer and components, aerospace defense and education all require
Vector Signal Analyzer FSQ-K70
Product brochure Version 02.00 Vector Signal Analyzer FSQ-K70 July 2004 Universal demodulation, analysis and documentation of digital radio signals For all major mobile radio communication standards: GSM
MIMO RF Signal Analysis and Generation Test Systems and Software
What s New? Now up to 8 8 configurations Ideal for antenna research, 802.11n WLAN, 802.16e mobile WiMAX Wave 2, and LTE Excellent Performance 40MHz bandwidth High performance platforms, 2820 SISO EVM -40dB
Signaling Conformance Option
spirent C2K-ATS The Signaling Conformance solution for the C2K-ATS platform automates Signaling Conformance testing of CDMA 1X and EV-DO mobile devices. APPLICATIONS Product Development Design Verification
APPLICATION NOTE. Easily Create Custom Waveform Plug-Ins With Waveform Creator Application Software
APPLICATION NOTE Easily Create Custom Waveform Plug-Ins With Waveform Creator Application Software Challenge the Boundaries of Test Agilent Modular Products Enable higher productivity through a simple,
Power Amplifier Gain Compression Measurements
Technical Brief Power Amplifier Gain Compression Measurements GPIB Private Bus Sweep Out Sweep In Pulse In AC Mod Out Blank/Marker Out Blanking In Overview The 1 db gain compression of an amplifier describes
Agilent Network Monitoring Content Intercept Manager
Agilent Network Monitoring Content Intercept Manager Enabling Lawful Intercept agencies to keep pace with evolving cellular networks CIM is a flexible tool allowing precise and secure lawful interception
Test Toolkit. 290101 v3.0 SignalMeister RF Communications
Waveform creation and analysis software for Series 2900 VSGs, Series 2800 VSAs, and systems Industry s only fully integrated signal generation and analysis software package Unique, seamless -to-8 8 signal
Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics
Jeff Thomas Tom Holmes Terri Hightower Learn RF Spectrum Analysis Basics Agenda Overview: Spectrum analysis and its measurements Theory of Operation: Spectrum analyzer hardware Frequency Specifications
Wireless Technology Test Challenges Facing the Automotive Industry
Wireless Technology Test Challenges Facing the Automotive Industry October 2015 John Russell Keysight Technologies 1 Connected Car A Connected Lifestyle Is A Given Automakers agree that building connected
Modular Instrumentation Technology Overview
Modular Instrumentation Technology Overview Outline Overview of the PXI Platform PCI & PXI Express The Future of RF Leveraging Modular Instrumentation Mixed signal test Streaming RF Streaming Demo Summary
PCI Express 1.0 (2.5 GT/s) Protocol Test
PCI Express 1.0 (2.5 GT/s) Protocol Test Configuration and Pricing Guide Gen1 today, ready for Gen2 in the future As PCI Express Gen2 becomes more mature in the market, you must decide whether to continue
Agilent Automotive Power Window Regulator Testing. Application Note
Agilent Automotive Power Window Regulator Testing Application Note Abstract Automotive power window regulator tests require the use of accurate data acquisition devices, as they cover a wide range of parameters
FPGAs in Next Generation Wireless Networks
FPGAs in Next Generation Wireless Networks March 2010 Lattice Semiconductor 5555 Northeast Moore Ct. Hillsboro, Oregon 97124 USA Telephone: (503) 268-8000 www.latticesemi.com 1 FPGAs in Next Generation
Agilent Spectrum Analyzer and Signal Analyzer Selection Guide
Agilent Spectrum Analyzer and Signal Analyzer Selection Guide Introduction Agilent Technologies' extensive array of signal analyzer products, from DC to 325 1 GHz and beyond, address whatever application
Achieving New Levels of Channel Density in Downstream Cable Transmitter Systems: RF DACs Deliver Smaller Size and Lower Power Consumption
Achieving New Levels of Channel Density in Downstream Cable Transmitter Systems: RF DACs Deliver Smaller Size and Lower Power Consumption Introduction By: Analog Devices, Inc. (ADI) Daniel E. Fague, Applications