1 Eurotherm Chessell Graphic Data Acquisition Recorders Ethernet Communication Data Historian, Reports, Real Time Monitor Monitor Energy Consumption, texturizers, 5180V Display. Display. Management. * 12.1" Color SVGA TFT Touchscreen Display * Up to 48 Input Channels * Up to 27 Alarm relays * Up to 256 MB PCMCIA card data storage * * 5100V High visibility Current and historic data sets * 5.5" Color SVGA TFT Touchscreen Display * Up to 12 Input Channels * Up to 12 Alarm relays * Up to 256 MB PCMCIA card data storage 5100e Universal inputs Unmatched Accuracy * 5" Color, 1/4VGA STN Touchscreen Display * 6 Input Channels * 1 Relay output * Floppy disk drive and 3 MB Flash data storage e.

2 Eurotherm Chessell K5100V and K5180V Graphic Data Acquisition Recorder 100mm and 180mm 5100V No inputs Display type 5.5" (139.7mm)(1/4 VGA) TFT color LCD 5180V 12.1" (307.34mm)(SVGA) TFT color LCD User interface Touch sensitive screen Touch sensitive screen Configurable Yes Yes Relay outputs Communications Ethernet Ethernet Datalogging Yes Yes Archive media ATA & compact flash or 3.5" disk ATA & compact flash or 3.5" disk Totalizers, timers and counters Yes Yes The 5100V and 5180V process viewers, are the first recorders in a brand new range of data acquisition (DAQ) units. At the heart of the design is a leading edge technology Power PC, 32 bit RISC processor. Ethernet networking has become the recognized standard for high-speed data transmission within large plants and beyond. Series 5000 incorporates FTP (file transfer protocol) via its Ethernet communications, enabling the archiving of data into the plant-wide data network. Data visualization needs to be presented in the most easily interpretable format to the operator. In addition to the standard displays of bar, chart and numeric formats, custom displays (plant mimics) can be created for the series 5000 recorders. The advanced software environment allows for display creating images that are both static, and have moving elements. A Touch Sensitive Screen coupled with a ¼ VGA or SVGA TFT color LCD display provides excellent display capabilities. The Series 5000 features a simple to use WindowsTM style system configurator, that is mirrored in the PC-based configuration program, allowing ease of transition between either method of set up. Distributed Worldwide by sales@mcgoff-bethune.com Web Site:

3 Review PC Softwareis included in the base system. Review is a powerful tool for the analysis, display, databasing and export of archived process data. Review provides an easy way to review stored data by point, time, plant-unit and batch number. Designed to view and print historical data produced by Chessell s intelligent chart recorders and data acquisition units, all channels retain their original trace colors, identifiers and scales, ensuring easy comparison of data with that on the recorder unit. Bridge 5000 is PC software that provides remote access to the series 5000 recorders, via Ethernet. Using the software, the operator sees real time data from the recorder. Navigation of the operator interface on the PC is identical to that of the unit, using a mouse to point and click where the recorder uses a touch screen. Archiving is available on a choice of media, either 3.5 floppy diskette, PC card, or hard drive with up to 1 Gbyte of memory. Data is transferred from the instrument s non-volatile memory in hourly, daily or weekly files. Data can be archived at a rate which matches the units high input scan rates 8Hz. All data is stored in tamper-proof binary format that can be used for long term record processing. The Batch 5000 feature offers batch functionality based on the requirements of FDA title 21 CFR part 11. The capabilities of this feature include: entering of six batch fields (e.g. current operator, batch number, customer name, order number, etc.), batch mode (start/stop or continuous). OPC server capability (OLE for process control) defines the standard by which instrumentation can be integrated into modern automation/business systems. This enables Series 5000 recorders to be incorporated into the software system of your choice, without the need to assemble costly new drivers. Use of the Eurotherm custom chip set ensures high quality I/O. One A/D converter per channel negates the need for relays or solid state switching, providing continuous measurement and parallel sampling for each input. High noise rejection and isolation (250 volts channel to channel and channel ground) ensures measurement integrity in the harshest of environments. This high accuracy data acquisition occurs at an input scan rate of 8Hz (all channels scanned every 125ms). The 5100V and 5180V Process Viewers are the first products to be released in a brand new range of graphical data acquisition recorders. At the heart of the design is a leading edge technology 32 bit RISC processor. High Quality I/O Series 5000 utilizes the Eurotherm custom chip set. One A/D converter per channel negates the need for relays or solid state switching, providing continuous measurement and parallel sampling on each input. High noise rejection and isolation (250 volts ch/ch & ch/gnd) ensures measurement integrity in the harshest of environments. Touch Sensitive Screens coupled with 1/4 VGA or full SVGA TFT color LCD displays, provide excellent viewing. The Series 5000 features a simple to use Windows-style system configurator that is mirrored in the PC based configuration program. This enables easy transition between the two methods of set up. Distributed Worldwide by sales@mcgoff-bethune.com Web Site:

4 TECHNICAL SPECIFICATION (Recorder) Board types and hardware options Six-channel universal input Model 5180V: Eight boards (48 channels) max Model 5100V: Two boards (12 channels) max Three Change-over relay output board Model 5180V: Nine boards (27 outputs) max Model 5100V: Two boards (six outputs) max 3.5 inch floppy disk, or PC Card (ATA flash or hard disk) Environmental Performance Temperature limits PC Card option: Operation: 0 to 50ºC; Storage: 25 to 70ºC Floppy disk drive option: Operation: 5 to 40ºC ; Storage: 20 to + 50ºC Humidity limits PC Card option: Operation: 8% to 85% RH; Storage: 8% to 90% (both non-condensing) Floppy disk drive option: Operation: 20% to 80% RH; Storage: 8% to 80% (both non-condensing) Protection Bezel and display IP65 Shock BS EN61010 Vibration (10 to 150Hz) 2g peak Altitude <2000m Electromagnetic compatibility (EMC) Emissions BS EN Immunity BS EN Electrical safety (BS EN61010) Installation cat. II; Pollution degree 2 A Physical (Model 5100V) Panel mounting DIN43700 Bezel size 5.67" (144mm) x 5.67" (144mm) Panel cutout dimensions 5.43" (138mm) x 5.43" (138mm) [both " (1mm)] Depth behind bezel rear face 9.76" (248mm) B PANEL CUTOUT Weight 6.6lb (3kg) Panel mounting angle Recorders with hard disk: Vertical panel only Recorders with floppy disk: ± 15º Other 5100V recorders: ± 45º Physical (Model 5180V) Panel mounting DIN43700 Y Bezel size 11.3" (288mm) x 11.3" (288mm) Panel cutout dimensions 11.1" (281mm) x 11.1" (281mm) [(both " (1mm)] Model A x B Side clamps Depth behind bezel rear face 12" (305mm) 138 x X = 15 mm ( ) mm Y = 10 mm Weight 16.5lb (7.5kg) Panel mounting angle Recorders with hard disk: Vertical panel only Recorders with floppy disk: ± 15º Other 5180V recorders: ± 45º Operator interface Type Colour TFT LCD with cold cathode backlighting. Fitted with resistive, analog, toughened touch-panel Size and resolution Model 5100V: 1/4 VGA (320 x 240 pixels) Model 5180V: SVGA (800 x 600 pixels) Power requirements Line voltage 47 to 63Hz 85 to 265V Power (Max) 60VA (Inrush current 36A) Fuse type None Ethernet communications Electrical standard 10Mbs Ethernet. 10BaseT. Transport protocol TCP/IP. File Transfer Protocol (FTP). Modbus TCP/IP x 281 ( ) mm X = 25 mm Y = 12.5 mm X Minimum recommended spacing Top/bottom clamps X = 10 mm Y = 15 mm INSTALLATION CATEGORY II The rated impulse voltage for equipment on nominal 230V mains is 2500V. POLLUTION DEGREE 2 Normally, only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation shall be expected. X = 12.5 mm Y = 25 mm Model 5100V/5180V Specification Sheet

5 TECHNICAL SPECIFICATION (Input board) General Input types Input type mix Maximum number of inputs Input ranges Termination Noise rejection (48 to 62Hz) Maximum common mode voltage Maximum series mode voltage dc V, dc mv, dc ma (with shunt), Thermocouple, 2/3-wire RTD Contact closure (not chan. 1) >60ms Freely configurable 6 per board See Table1 and Table 3 below Edge connector/terminal block Common mode: >140dB (channel to channel and channel to ground) Series mode: >60dB 250V continuous 45mV at lowest range; 12V peak at highest range Isolation (dc to 65 Hz; BS EN61010) Installation cat II; Pollution degree 2 Channel to channel: 300V RMS or dc (double insulation) Channel to common electronics: 300V RMS or dc (double insulation) Channel to ground: 300V RMS or dc (basic insulation) Dielectric strength (BS EN61010) (1 minute type tests) Channel to channel 2300 Vac Channel to ground 1350 Vac Insulation resistance >10MΩ at 500 V dc Input impedance 38mV, 150mV, 1 V ranges: >10MΩ; 10V range: 68.8kΩ Over voltage protection 50V peak (150V with attenuator) Open circuit detection ± 57nA max Recognition time 500msec Minimum break resistance 10MΩ Update/archive rates Input/Relay-output sample rate 8Hz Display update 1Hz Archive sample-value Latest value at archive time Trend/Display value Latest value at display update time DC Input ranges Shunt Externally mounted resistor modules Additional error due to shunt 0.1% of input Additional error due to attenuator 0.2% of input Performance See table 1 Low -8 mv -30 mv -0.2 Volt -2 Volts High 38mV 150mV 1 Volt 10 Volts Maximum error Resolution (Instrument at 20 C) 1.4µV 0.085% input % range 5.5µV 0.084% input % range 37µV 0.084% input % range 370µV 0.275% input % range Table 1 DC performance Worst case temperature performance 80ppm of input per deg C 80ppm of input per deg C 80ppm of input per deg C 272ppm of input per deg C Input board specification (Cont.) Thermocouple data Temperature scale ITS 90 Bias current 0.05nA Cold junction types Off, internal, external CJ error 1ºC max with inst. at 25ºC CJ rejection ratio 50:1 minimum Remote CJ Via any user-defined channel Upscale/downscale drive High, low or none, selectable for each thermocouple channel Additional error: 0.01ºC (typ.) if high or low selected Types and ranges See table 2 Resistance inputs s (including lead resistance) 0 to 150Ω, 0 to 600Ω, 0 to 6kΩ Influence of lead resistance Error = negligible; Mismatch = 1Ω/Ω Temperature scale ITS90 Accuracy and resolution See table 3 Low 0Ω 0Ω 0Ω RTD type Cu10 JPT100 Ni100 Ni120 Pt100 Pt100A Pt1000 T/C Type Overall range ( C) Standard Maximum linearisation error B 0 to IEC to 400 C: 1.7 C 400 to 1820 C: 0.03 C C 0 to Hoskins 0.12 C D 0 to Hoskins 0.08 C E -270 to IEC C G2 0 to Hoskins 0.07 C J -210 to IEC C K -270 to IEC C L -200 to DIN43700: C (To IPTS68) N -270 to IEC C R -50 to IEC C S -50 to IEC C T -270 to IEC C U -200 to DIN43710: C NiMoNiCo -50 to ASTM E C Platinel 0 to Engelhard 0.02 C High Table 2 Thermocouple types andranges Resolution Maximum error (Instrument at 20 C) Worst case temperature performance 150Ω 600Ω 6kΩ 5mΩ 22mΩ 148mΩ 0.045% input % range 0.045% input % range 0.049% input % range 35ppm of input per deg C 35ppm of input per deg C 35ppm of input per deg C Table 3 Resistance ranges - accuracy and resolution Overall range ( C) -20 to to to to to to to Standard General Electric Co. JIS C1604:1989 DIN43760:1987 DIN43760:1987 IEC751 Eurotherm Recorders SA IEC751 Table 4 RTD types and ranges Max.linearisation error 0.02 C 0.09 C Relay outputs Maximum switching power* 500VA or 60W Maximum breaking current* 2A within above power ratings Maximum contact voltage* 250V within above power ratings Isolation Contact to contact: 300V RMS or dc (double insulation) Contact to ground: 300V RMS or dc (basic insulation) Estimated life* 30,000,000 operations * With resistive loads. With inductive loads, derate according to the graph, in which: Contact life = resistive life x F1 or F2 where F1 = measured on representative examples and F2 = typical values according to experience Power factor (cos φ) All isolation figures are: DC to 65Hz; BS EN61010 Installation category II; Pollution degree 2 Reduction Factor F 0.9 1F F1 F2 EUROTHERM RECORDERS INC HP261809X200 Issue 08/01

6 Review Software Review Software is included standard with each 5100 DAQ Recorder View historical data on PC Modify and compress displayed data Combine data from multiple recorders Secure source data Output data to printer or standard spreadsheet packages Display Data Review software is a powerful tool for the analysis, display, databasing and export of archived process data. Review provides an easy way to review stored data by point, time, plant-unit and batch number. Designed to view and print historical data produced by Chessell s intelligent chart recorders and data acquisition units, all channels retain their original trace colors, identifiers and scales, ensuring easy comparison of data with that on the recorder unit. Source Data Remains Secure Source data is retained in a database in the binary format used by Chessell s recorders and data acquisition equipment. This binary format provides data security once written, process values in the data cannot be tampered with. Data Export Once within the PC environment, process data is stored on hard disk for easy and instant access. The data is easily copied to the Windows clipboard for integration into other reporting packages such as spreadsheets, or word processing packages. Displayed data can also be exported as ASCII comma delimited files. Printer Output Any windows supported printer will produce attractive hard copy outputs in black and white, or color. Process data is printed with scales, channel identifiers and time markers. Remote File Transfer Review has a facility for the remote transfer of data and configurations. Files stored on the recorder s local archive drive are transferred between the unit and a PC, over the instruments serial communications. Available on the: 41003C, 4103M, 4100G, and 5100V this features: Automatic (timed) or operator requested transfer of archived data files from recorder to PC Save recorder configuration to archive drive Restore configuration from archive drive to recorder Delete files on archive drive This feature is ideal for large plants and remote sites where data files need to be gathered on a daily or weekly basis, for quality record purposes.

7 BRIDGE 5000 REMOTE VIEWER INTRODUCTION This feature allows the user to view recorder standard screens, dynamically, on-line, from any PC which meets or exceeds the minimum requirements listed below. The software is supplied on a CD ROM, which also includes PC review, PC Configuration and Acrobat reader software and various manuals relevant to the recorder. The Remote viewer software is suitable for any physical hardware configurations, some common examples being: 1. A single PC connected directly to a recorder. 2. Multiple PCs connected via a network to one or more recorders. (Each recorder can be accessed by a maximum of four PCs, but one PC can look at a number of recorders depending on available memory. For example, a minimum specification computer (section 6.1.1) running Windows NT can look at up to three recorders.) 3. A single PC connected via a telephone line to a remote recorder. This manual does not attempt to describe network setup in detail, as each network is different. In most cases, the help of the network administrator or supervisor will be required, for example, in the allocation of valid addresses and passwords. Minimum PC requirements 1. P90 running Windows 95/98/NT 2. 32MB RAM 3. 50MB free hard disk space 4. Graphics drive capable of displaying > 256 colours (recommended) CONNECTION DETAILS The connection to the recorder is terminated at the RJ45 connector located as shown in figures 2.2.1a, 2.2.1b). The other end of the cable may be terminated, for example, at a hub, a dial-up router or a PC, and it is up to the user to obtain a suitable cable (normally available from a computer supplier or electronic component distributor.) Note: For direct connection between a PC and the recorder, a crossover cable is required. For all other connections, a 'straight-through' connection is required. Direct PC connection The RJ45 connector at the rear of the recorder is connected via a crossover cable to the PC network card connector.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise! Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Job Aid Pre-Installation Information S8500 Media Server

Job Aid Pre-Installation Information S8500 Media Server Required information Job Aid Pre-Installation Information S8500 Media Server This job aid provides the information, hardware requirements, and computer hardware and software specifications necessary for

More information

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5 - TFT - 96 MB Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis

More information

Solid as a Rock etop 300/400

Solid as a Rock etop 300/400 Solid as a Rock etop 300/400 5 years warranty E X O R I N T E R N A T I O N A L Product Presentation etop 300/400 At a glance Five years warranty Products available with a choice of two operating systems

More information

How to Use the PHF Digital Memory System

How to Use the PHF Digital Memory System Type: PHF Long Term Record Data Saving 4years in Compact Flash (In case of using 512MB Compact Flash) Saved Data playback Saved data in Memory card can be easily called out and played back on display (1Base-T)

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

EA7-T8C EA7-T10C EA7-T12C EA7-T15C

EA7-T8C EA7-T10C EA7-T12C EA7-T15C The new Generation of Touch Panels with ambitious image presentation and integrated operating function With the C-more series, featuring STN and TFT touch screens, AutomationDirect now provides the best

More information

UniOP epad33 and epad33t

UniOP epad33 and epad33t UniOP epad33 and epad33t The epad33 and epad33t are state-of-the-art HMI devices with a 10.4 graphic display and a complete keypad. The aluminum bezel offers an appealing look in a rugged and convenient

More information

V350-TA24 V350J-TA24. 225mA@24VDC 240mA@24VDC 240mA@24VDC

V350-TA24 V350J-TA24. 225mA@24VDC 240mA@24VDC 240mA@24VDC Vision OPLC V130/ V350/ Technical Specifications Order Information V130-33-TA24 PLC with Classic panel, Monochrome display 2.4" V130-J-TA24 PLC with Flat panel, Monochrome display 2.4" V350-35-TA24 PLC

More information

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved. SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,

More information

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware A+ Guide to Managing and Maintaining Your PC, 7e Chapter 1 Introducing Hardware Objectives Learn that a computer requires both hardware and software to work Learn about the many different hardware components

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

DC Electronic Loads 8500 series

DC Electronic Loads 8500 series Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating

More information

Ensto Chago Master EVM300 and EVM500 Operational description

Ensto Chago Master EVM300 and EVM500 Operational description Pages: 1 (8) Ensto Chago Master EVM300 and EVM500 Operational Pages: 2 (8) Contents 1 What is Ensto EVM... 3 2 EVM versions... 3 2.1 EVM300... 4 2.2 EVM500... 5 3 Technical information... 7 Pages: 3 (8)

More information

3500/93 System Display

3500/93 System Display 3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide

More information

Signal Conditioning Amplifier System

Signal Conditioning Amplifier System Micro-Measurements A2 FEATURES Strain gage, transducer, and thermocouple inputs Frequency response to 110 khz Analog output of ±10 VDC Operation with 12 to 15 VDC and 120/240 VAC power Scalable from 8

More information

Pyrotracer Video C.A 650

Pyrotracer Video C.A 650 Production lot traceability, at your fingertips Pyrotracer Video C.A 650 "Plug & play" paperless recorder for the traceability needs of the most demanding industry environments. Rapid set-up and ease of

More information

Digital Pressure Measuring Instrument MDR480

Digital Pressure Measuring Instrument MDR480 Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm

More information

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module

More information

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Paperless Graphic Recorders Specification Sheet

Paperless Graphic Recorders Specification Sheet Ideal for : 21CFR Part II Applications Furnaces, NADCAP Water/waste water Power generation Sterilizers, autoclaves Features : MODELS Colour touchscreen display Paperless Graphic Recorders Specification

More information

Product Data. Thermal Comfort Data Logger Type 1221. Including Application Software Type 7301

Product Data. Thermal Comfort Data Logger Type 1221. Including Application Software Type 7301 Product Data Thermal Comfort Data Logger Type 1221 Including Application Software Type 7301 USES: For measuring all physical parameters necessary to evaluate heat stress and thermal comfort For evaluating

More information

AXIS 262+ Network Video Recorder

AXIS 262+ Network Video Recorder 31433/EN/R4/0803 Complete Network Video Recording Solution Complete Network Video Recording Solution Picture this: A simple and reliable, plug-and-play video surveillance system for hotels, shops, banks,

More information

Easy Installation All five standard monitors fit into shallow mounting areas, requiring about 3" of depth. The XT1502, SXT1811, and SXT2011 models hav

Easy Installation All five standard monitors fit into shallow mounting areas, requiring about 3 of depth. The XT1502, SXT1811, and SXT2011 models hav Flat Panel Industrial Monitors FEATURES 10.4 to 20.1 bright, easy-to-read color TFT flat panel display with screen resolution from VGA to SXGA Large viewing area and viewing angles Operator input through

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control

More information

40.3. Control Relays and Timers

40.3. Control Relays and Timers .3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories

More information

Panel PC SIMATIC HMI IPC577C

Panel PC SIMATIC HMI IPC577C Product Data Sheet Rugged, expandable industry PC for demanding tasks in the area of PC-based automation with various control units (front panels): Rugged and compact design for industrial use Full PC

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information

Tracer Summit Web Server

Tracer Summit Web Server Tracer Summit Web Server Web-based access for the Tracer Summit building automation system March 2003 BAS-PRC014-EN Introduction The Tracer Summit Web Server provides the ability to operate a Tracer Summit

More information

Wahl C50 Calibrator FEATURES

Wahl C50 Calibrator FEATURES NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

5000V Graphical Megohmmeter Model 5070

5000V Graphical Megohmmeter Model 5070 5000V Graphical Megohmmeter Model 5070 The Model 5070, the latest design in 5000V Megohmmeters, is the most innovative product in its class on the market today. The features and functions incorporated

More information

Multi-Function Ground

Multi-Function Ground Multi-Function Ground Resistance SOIL RESISTIVITY TEster Model 6470-B Now measure ground resistance, soil resistivity and bonding resistance with one instrument! 2- and 4-Wire Bond Resistance/Continuity

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

1 Serial RS232 to Ethernet Adapter Installation Guide

1 Serial RS232 to Ethernet Adapter Installation Guide Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).

More information

NEW. EVEN MORE data acquisition and test stand automation

NEW. EVEN MORE data acquisition and test stand automation NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

MIT510/2, MIT520/2 and MIT1020/2

MIT510/2, MIT520/2 and MIT1020/2 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com MIT510/2, MIT520/2 and MIT1020/2 Line supply or battery operated Digital/analog

More information

www.foxboro.com/instrumentation EASY. SECURE. ADAPTABLE. Foxboro 6000 Series Data Management

www.foxboro.com/instrumentation EASY. SECURE. ADAPTABLE. Foxboro 6000 Series Data Management www.foxboro.com/instrumentation EASY. SECURE. ADAPTABLE. Foxboro 6000 Series Data Management EASY Easy to Install, Easy to Configure, Easy to Use... The features and functions of this innovative series

More information

Ultra Thin Client TC-401 TC-402. Users s Guide

Ultra Thin Client TC-401 TC-402. Users s Guide Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

NETWORK ENABLED EQUIPMENT MONITOR

NETWORK ENABLED EQUIPMENT MONITOR NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

Chapter 5 Cubix XP4 Blade Server

Chapter 5 Cubix XP4 Blade Server Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value. Vision OPLC V350-35-RA22/V350-J-RA22 Technical Specifications The Unitronics V350-35-RA22/V350-J-RA22 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog,

More information

V350-R34 V350J-R34. npn inputs 245mA@24VDC 275mA@24VDC 275mA@24VDC pnp inputs 170mA@24VDC 200mA@24VDC 200mA@24VDC

V350-R34 V350J-R34. npn inputs 245mA@24VDC 275mA@24VDC 275mA@24VDC pnp inputs 170mA@24VDC 200mA@24VDC 200mA@24VDC Vision OPLC V130-33-R34/V130-J-R34 V350-35-R34/V350-J-R34 V430-J-R34 Technical Specifications Order Information V130-33-R34 PLC with Classic panel, Monochrome display 2.4" V130-J-R34 PLC with Flat panel,

More information

1701/22 FieldMonitor Management Interface Module

1701/22 FieldMonitor Management Interface Module 1701/22 FieldMonitor Management Interface Module Bently Nevada Asset Condition Monitoring Description The 1701/22 FieldMonitor Management Interface Module (FMIM) is a highlyintegrated module that provides

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low

More information

2 1. 5 O pen F ram e Tou c h M on i t or

2 1. 5 O pen F ram e Tou c h M on i t or M TM G T- R TL 2 2 W- A 21.5" RE AR TOU C H MONITOR Trade SpA - Official European Distributor R eo O ar M ount R T L 1 7 3 2 1. 5 O pen F ram e Tou c h M on i t or R TL 2 2 W- A on i t or D at as h eet

More information

CQM1-SF200/CS1W-SF200

CQM1-SF200/CS1W-SF200 Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit

More information

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.

More information

SOLAR300N Rel. 1.03 21/01/10

SOLAR300N Rel. 1.03 21/01/10 Photovoltaic installation certifier + professional network analyzer Pag 1 of 5 1. SOLAR300N MAIN FEATURES SOLAR300N performs all tests on PV plants by using of SOLAR-02 remote unit which, after a preliminary

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

In-Sight Hardware specifications

In-Sight Hardware specifications specifications In-Sight 5000, 5100, 5400, 5400S, 5400C, 5401, and 5403 4020 Linz/Austria Pummererstr. 36 Tel.: +43-(0)70-7646-0* www.schmachtl.at Memory Job/Program 16MB non-volatile flash memory; Unlimited

More information

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog

More information

Fax Server. Blue Line IP ISDN ISDN PRI

Fax Server. Blue Line IP ISDN ISDN PRI Blue Line IP PRI Blue Line The corporate fax solution The corporate fax solution Communication by fax is essential to business life. Fax has many major advantages over email. It is well accepted, very

More information

Interface Adapters PS/2 Interface Adapter 1 pack 262588-B21 PS/2 Interface Adapter 8 pack 262587-B21 USB Interface Adapter 1 pack 336047-B21

Interface Adapters PS/2 Interface Adapter 1 pack 262588-B21 PS/2 Interface Adapter 8 pack 262587-B21 USB Interface Adapter 1 pack 336047-B21 Overview Models HP Server Console Switches 1X8-Port KVM 336044-B21 2X16-Port KVM 336045-B21 CAT5e Cables 3 Foot (1 m) 4 pack 263474-B21 6 Foot (2 m) 8 pack 263474-B22 12 Foot (4 m) 8 pack 263474-B23 20

More information

DMS-10101, Computer Equipment

DMS-10101, Computer Equipment Overview Effective dates: September 2005 - August 2006. This Specification describes the procedures for providing desktop microcomputers, laptop microcomputers, printers, and internet service for use on

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

1.44 kw Programmable DC Power Supplies XLN Series

1.44 kw Programmable DC Power Supplies XLN Series Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable

More information

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications Page 1 / 14 Technical specifications Page 2 / 14 SUMMARY 1. GENERAL OVERVIEW 1.1 MIOS and the remote management 1.2 The MIOSBOX range 1.3 Synthesis of MIOSBOX s specificities 2. DETAILED PRESENTATION OF

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es

More information

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules

More information

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

PU-USBX. USB over Ethernet Extender OPERATION MANUAL PU-USBX USB over Ethernet Extender OPERATION MANUAL Safety Precautions Please read all instructions before attempting to unpack or install or operate this equipment, and before connecting the power supply.

More information

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch

More information

Cisco 7816-I5 Media Convergence Server

Cisco 7816-I5 Media Convergence Server Cisco 7816-I5 Media Convergence Server Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks, enabling easy collaboration every time from

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION MACHINEMATE CNC SYSTEM Hardware SPECIFICATION Feb 2005 CONTENTS 1 Introduction / General... 3 1.1 Superior Capability in Technology and Productivity... 3 1.2 General hardware components... 4 1.3 Static

More information

Features. Introduction. Applications. VPD-130/VPD-130N with DIN-Rail Mounting. VPD-130/VPD-130N Panel Mounting. Excellent C/P ratio (cost/performance)

Features. Introduction. Applications. VPD-130/VPD-130N with DIN-Rail Mounting. VPD-130/VPD-130N Panel Mounting. Excellent C/P ratio (cost/performance) Features Excellent C/P ratio (cost/performance) High-resolution color touch screen RTC (Real Time Clock) Supports 1 Serial Port (RS-232/RS-485, including Self-Tuner) Rubber Keypad WYSIWYG (What You See

More information

EUROTHERM MASTER COMMUNICATIONS 5000 Series with Master Communications for unsurpassed access to process data everywhere

EUROTHERM MASTER COMMUNICATIONS 5000 Series with Master Communications for unsurpassed access to process data everywhere EUROTHERM MASTER COMMUNICATIONS 5000 Series with Master Communications for unsurpassed access to process data everywhere CONNECTIONS MADE EASY The 5180V, 5100V and 5000B now all support Modbus Master Communications

More information

Foxboro Evo Process Automation System

Foxboro Evo Process Automation System Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053. PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection

More information

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give

More information

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications 077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Vision OPLC. V350-35-R34/V350-J-R34 Technical Specifications. Technical Specifications

Vision OPLC. V350-35-R34/V350-J-R34 Technical Specifications. Technical Specifications Vision OPLC V350-35-R34/V350-J-R34 Technical Specifications The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information