Coaxial Cable Performance and Application Guide
|
|
- Cassandra Wilcox
- 7 years ago
- Views:
Transcription
1 Coaxial Cable Performance and Application Guide
2 COAXIAL CABLE PERFORMANCE AND APPLICATION GUIDE Content Page 1. INTRODUCTION GENERIC SYSTEM OVERVIEW CABLE SPECIFICATIONS CABLE RECOMMENDATIONS DS3 CABLING SUMMARY SYSTEM INTEGRATION SERVICES CUSTOMER SUPPORT SERVICES RECOMMENDED PROCEDURES FOR COAXIAL TERMINATION TYPE 728 CABLE WITH BNC AND TNC STRAIGHT PLUG CONNECTORS WITH LOCKING CENTER CONDUCTOR RECOMMENDED PROCEDURES FOR COAXIAL TERMINATION TYPE 728 CABLE WITH BNC 90 DEGREE PLUG CONNECTORS RECOMMENDED PROCEDURES FOR COAXIAL TERMINATION TYPE 734A CABLE WITH BNC AND TNC STRAIGHT CONNECTORS WITH LOCKING CENTER CONDUCTOR RECOMMENDED PROCEDURES FOR COAXIAL TERMINATION TYPE 734A CABLE WITH BNC 90 DEGREE PLUG CONNECTORS RECOMMENDED PROCEDURES FOR COAXIAL TERMINATION TYPE RG59B/U CABLE WITH BNC AND TNC STRAIGHT CONNECTORS WITH LOCKING CENTER CONDUCTOR RECOMMENDED PROCEDURES FOR COAXIAL TERMINATION TYPE RG59B/U CABLE WITH BNC 90 DEGREE PLUG CONNECTORS RECOMMENDED PROCEDURES FOR COAXIAL TERMINATION TYPE 735A CABLE WITH BNC AND TNC STRAIGHT CONNECTORS WITH LOCKING CENTER CONDUCTOR RECOMMENDED PROCEDURES FOR COAXIAL TERMINATION TYPE 735A CABLE WITH BNC 90 DEGREE PLUG CONNECTORS RECOMMENDED PROCEDURES FOR COAXIAL TERMINATION TYPE 0222 CABLE WITH BNC AND TNC STRAIGHT CONNECTORS WITH LOCKING CENTER CONDUCTOR RECOMMENDED PROCEDURES FOR COAXIAL TERMINATION TYPE 0222 CABLE WITH BNC 90 DEGREE PLUG CONNECTORS INTRODUCTION 1.01 Dynamic expansion of DS3 transmission has challenged network planners and engineers to seek new and practical ways to plan for this growth while maintaining network performance at acceptable levels. DS3 network services have significantly impacted the need for increased density in the DSX-3 arena This need for increased density is driven by the shortage of office space and a desire to maximize new and existing line-ups while maintaining the DSX-3 pulse template, voltage, and power requirements. As density has increased in DSX-3 products, cable used to terminate these products has evolved from 728-type cable to smaller RG59/735-type cables. Even with high density DSX-3 products and smaller coaxial cable; however, the DSX-3 area continues to expand to larger line-ups in which the cross-connects are exceeding the 27-foot limitation. Page 1
3 1.03 In order to address the issues of higher densities and equipment compatibilities, interface standards such as Compatibility Bulletins, Technical Advisories and the American National Standards have been established. The T1 Telecommunications Technical Committee, an accredited sub-committee of the American National Standards Institute (ANSI), was established in ADC Telecommunications is an active member company of this technical committee. Representatives making up this committee are manufacturers and service and network providers who are working to establish interface standards for the telecommunications industry. 2. GENERIC SYSTEM OVERVIEW 2.01 The DS3 transmission facility consists of several components that make up the network. Of specific concern is the equipment typically located in the central office (CO) where signals are handed off from carrier to carrier. Throughout this complex network, all signaling eventually reaches a central location - the digital signal cross-connect (DSX) point. The DSX forms a centralized cross-connect (digital distribution frame) for these digital signals The DSX-3 system is designed for a specific signal level at the 45 Mb/s DS3 signal rate. In a typical installation as shown in Figure 1, all digital equipment is terminated at the DSX-3. In order to assure equal signal levels (equal voltage, power level, correct digital pulse shape, and matching line impedance), output levels of all digital equipment are equalized by customer-supplied components. T1/ TWISTED PAIR COAXIAL CABLE COAXIAL CABLE COAXIAL CABLE FIBER OPTIC CABLE M1/3 MULTIPLEXER DSX-3 DSX-3 FIBER OPTIC TERMINAL 4398-A COAXIAL SECTION OF A DS3 NETWORK Figure 1. Typical DS1-to-DS3-to Fiber Network 2.03 Several types of customer-supplied signal treatments to establish equal levels and pulse shape characteristics are used to compensate for the effects of the transmission medium. These include attenuator pads, equalizers, line build-out (LBO) networks, matching networks, and automatic line build-outs (ALBOs) The level of the signal applied to the cable pair must be set in accordance with the physical location of the signal source along the transmission medium. This is done to assure that equal levels of the signal traverse the cable in the same direction as the signal sources. Page 2
4 The advantage of equal-level transmission is that signals arrive at their destinations at the same nominal level, therefore simplifying digital equipment processing, reducing crosstalk, and minimizing mutual interference between adjacent channels Line build-outs (LBOs) and attenuator pads are used at the transmitter or source equipment to pre-distort or pre-shape the transmission waveform. This compensates for variations in cable length and other operational environments between the signal source and the DSX equal-level point Matching networks are used to compensate for echoes caused by impedance mismatches. These irregularities are an important source of waveform distortion. Improved impedance matching at junctions in the transmission medium is a good method for reducing this type of signal distortion/variation Equalizers and automatic line build-outs (ALBOs) are used at the receive equipment to establish the proper signal level and pulse shape required by the receiver. This is referred to as the input sensitivity of the receiving device. An ALBO circuit followed by an amplifier incorporates fixed equalization and gain. Typically, the fixed section incorporates the appropriate gain and equalization for the maximum expected cable loss. The output of the fixed equalizer is sampled by a detector that provides feedback to the ALBO section, adding frequency-shaped loss until the total fixed and shaped output signal reaches the desired value (see Figure 2). SIGNAL ALBO (SIGNAL SHAPE) FIXED EQUALIZATION AND GAIN REGENERATOR FEEDBACK DETECTOR CLOCK 4397-A Figure 2. Typical Automatic Line Build-out (ALBO) Circuit 2.08 These build-out networks and equalization techniques, in addition to the cable characteristics, constitute the transmission environment. Cross-talk, noise thresholds, transmitter power and receiver sensitivity are also key considerations in determining performance requirements during network planning for any given transmission medium. 3. CABLE SPECIFICATIONS 3.01 Based on Bellcore Specification TR-NPL and ANSI Standard T , cable characteristics have been used to establish a transmission loss budget that includes 11 db of insertion loss for IN and OUT cables, and 1.15 db of insertion loss for the cross-connect frame, including the cross-connect cable. Page 3
5 3.02 The maximum distance from the transmission/multiplex equipment to the DSX termination is 450 feet ( m), depending on cable type. The maximum DSX crossconnect cable length has been established at 27 feet from the OUT to the IN circuit crossconnection. Cable length from the DSX to the terminal equipment is also 450 feet, maximum. 4. CABLE RECOMMENDATIONS 4.01 The maximum length recommended for IN and OUT cross-connect cables is based on a generic cable; however, specific cables exhibit their own unique characteristics. Figure 3 discusses the key cable-selection considerations and provides the formula used for calculating the cable lengths listed in Table 1. Table 1 lists the system cable length limits for IN/OUT cables and cross-connect cables for the DS3 transmission environment, based on the already-mentioned db and 1.15 db cross-connect frame budgets. The information provided may be used as a rule of thumb for system planning and limitation approximations based on variables designed into the network as a result of the cable type and DSX equipment selected for the individual application. When cross-connects exceed recommended lengths, DS3 intra-office repeaters should be used to ensure proper network performance. Equal level transmission for the purposes of minimizing transmission disturbances has been deployed in the network. This has resulted in establishment of the power levels and sensitivity levels of the transmit and receive equipment, as well as established the appropriate levels at the DS3 crossconnect. In addition, attenuation loss budgets have been established for the interconnecting cable and DSX-3 crossconnect. The DSX-3 cross-connect is assigned an insertion loss budget of 1.15 db, maximum, at MHz, including the loss of 27 feet of cross-connect cable (728 or equal). The In/Out cabling insertion loss is assigned 11.0 db at MHz. This is based on actual cable measurements of AT&T 728 cable at a length of 900 feet. The basis for these specifications results from attenuation of a coaxial transmission line. Assuming the transmission line follows an approximate f (root frequency) law, the transmission medium insertion loss can be estimated using the formula shown at right if the following characteristics are known: Nominal attenuation for a specified length of cable at a specified frequency. db=a (Ld) (Ls) (Fd) (Fs) where: db = Insertion Loss A = Specified Attenuation Ld = Desired Length of Cable Ls = Specified Length of Cable Fd = Desired Frequency Fs = Specified Frequency Example: Total Loss Budget DSX Loss Remainder for X-Conn db=a (Ld) (Ls) db=a (100)(0.484 db) Ld = MHz MHz db db db (Fd) (Fs) For 728 cable, A = db loss for 100 feet of cable at 100 MHz. (Ld) MHz 100 MHz = B Figure 3. Key Technical Considerations Page 4
6 4.02 With the loss characteristics identified, a logarithmic curve was established and was used to create a formula that determined the cable loss at specific frequencies ADC cautions against shortening the IN/OUT cables in order to further extend the cross-connect lengths. Shortening the IN/OUT cables or removing the LBOs changes the signal level at the DSX and may overload the receiving equipment, resulting in transmission errors. Also, the signal will no longer be at an equal level. If the signal is out of equal level, it will have an impact on the flexibility of the patching and cross-connect rearrangement at the DSX Table 1 lists the eight types of cables that are used as cross-connects. Each cable type was tested to verify the insertion loss characteristic. The cross-connect lengths were determined by testing the loss of 100 feet of cable from 10 MHz to 500 MHz (735A cable was tested at 10 MHz to 300 MHz). The loss characteristics differ in each type of cable; consequently, the maximum length for each cable differs. The specific cross-connect lengths were determined by adding together the loss of IN/OUT cable (from equipment to DSX-3 and from DSX-3 to equipment) and the loss of the specific cross-connect cable. Total system loss budget allowed for the matrix (end-to-end loss) was db for IN/OUT cables and 1.15 db for the two DSX-3 modules and cross-connect patch cords, for a db maximum. Table 1. Maximum Length in MHz (DS3) CABLE TYPE IN/OUT CROSS-CONNECT AT&T Belden Belden RG-59 B/U RG-59 with Messenger Wire AT&T 734A Belden 734 (Equivalent) AT&T 735A Belden 735A (Equivalent) The cable lengths shown in this matrix are actual loss characteristics of the cable and are not affected by either the LBOs or the ALBOs. Page 5
7 5. DS3 CABLING SUMMARY 5.01 The insertion loss test diagram and graphs were used to determine the loss of the DS3 cable found in the cabling matrix. Each cable was tested using a Hewlett Packard 4195A Network/Spectrum Analyzer and two 50-to-75 ohm minimum loss attenuators as shown in Figure 4. HEWLETT PACKARD 4195A 10 MHz TO 500 MHz NETWORK/SPECTRUM ANALYZER FREQUENCY SWEEP (HORIZONTAL AXIS) ALL CABLES EXCEPT 735A MHz 735A CABLE MHz CHANNEL A RF OUTPUT CHANNEL B RF OUTPUT RESOLUTION BANDWIDTH 300 MHz 300 MHz 50/75 50/75 50 TO 75 OHM MINIMUM LOSS ATTENUATORS (2) POWER RESOLUTION (VERTICAL AXIS) 10 db/div 10 db/div TEST SET IS LOOPED TO ESTABLISH ZERO REFERENCE LEVEL CABLE IS ADDED TO TEST CIRCUIT TO MEASURE LOSS 100 FEET NOTE: 1. ALL TEST CONNECTORS ARE 75 OHM ±5%. 2. TEST CABLES ARE 75 OHM ±5% PRECISION VIDEO (BELDEN #9231) A Figure 4. Insertion Loss Test Diagram 5.02 Each cable was cut to a length of 100 feet and terminated with two 75 ohm BNC connectors. Tests were conducted by using a frequency sweep of 10 MHz to 500 MHz (10 MHz to 300 MHz for 735 cable), which established the loss characteristics over the frequency spectrum. Examples of the loss characteristics are as follows: Cable Type: AT&T 728A N FREQUENCY (MHZ) T/R (DB) m m MEASURE N = 1 SWEEP N = 1 RBW: 300 MHz ST: 961 msec START: MHz 10 STOP: MHz RANGE: R = 10, T = 10 dbm Page 6
8 Cable Type: Belden 9231 N FREQUENCY (MHZ) T/R (DB) m m MEASURE N = 1 SWEEP N = 1 RBW: 300 MHz ST: 961 msec START: MHz 10 STOP: MHz RANGE: R = 10, T = 10 dbm Cable Type: Belden RG59B/U N FREQUENCY (MHZ) T/R (DB) m MEASURE N = 1 SWEEP N = 1 RBW: 300 MHz ST: 961 msec START: MHz 10 STOP: MHz RANGE: R = 10, T = 10 dbm Page 7
9 Cable Type: Belden 734A N FREQUENCY (MHZ) T/R (DB) m MEASURE N = 1 SWEEP N = 1 RBW: 300 MHz ST: 961 msec START: MHz 10 STOP: MHz RANGE: R = 10, T = 10 dbm Cable Type: AT&T 734A N FREQUENCY (MHZ) T/R (DB) m m MEASURE N = 1 SWEEP N = 1 RBW: 300 MHz ST: 961 msec START: MHz 10 STOP: MHz RANGE: R = 10, T = 10 dbm Page 8
10 Cable Type: RG59 with Messenger Wire N FREQUENCY (MHZ) T/R (DB) m MEASURE N = 1 SWEEP N = 1 RBW: 300 MHz ST: 961 msec START: MHz 10 STOP: MHz RANGE: R = 10, T = 10 dbm Cable Type: 735A N FREQUENCY (MHZ) T/R (DB) MEASURE N = 1 SWEEP N = 1 RBW: 300 MHz ST: 961 msec START: MHz 10 STOP: MHz RANGE: R = 10, T = 10 dbm Page 9
11 BNC Connector Specifications PARAMETER SPECIFICATION Electrical Characteristic Impedance 75Ω ± 5% Voltage Rating 1000 Volts RMS Insertion Loss < 0.6 db, 1 MHz to 1 GHz (measured with 1 meter of 728 cable) Return Loss 26 db, 1 MHz to 1 GHz Contact Resistance Ω maximum change, post-environmental Insulation Resistance Mechanical Mechanical Durability Center Contact Retention Coupling Mechanism Retention Force Cable Bend and Twist Force to Engage/Disengage Environmental Thermal Shock Moisture Resistance 200 megohms, minimum 500 cycles minimum 4 lbs minimum 100 lbs minimum 500 cycles minimum (or failure of the cable, whichever comes first) Torque 2.5 in/lb maximum Longitudinal force 3.5 lbs maximum, 5.0 lbs maximum, post-environmental 40 to 65 C operating, 55 to 85 C non-operating 0 to 95%, relative humidity, MIL-STD-202 Method 106 MIL-STD-202 Method 101, Test Condition B UL 94-VO rated (center conductor insulator) Corrosion (Salt Spray) Flammability Vibration MIL-STD-202 Method 201 Solvent Resistance MIL-STD-202 Method 215 Finish Body/Bayonet Electroless nickel plate, tarnish resistant Center Conductor 50 millionths inch gold plating, MIL-G Type 1, Grade C, Class 1 Page 10
12 6. SYSTEM INTEGRATION SERVICES 6.01 ADC offers the following system integration services. For calls originating in the U.S.A. or Canada, dial , extension For calls originating outside the U.S.A. or Canada, dial Technical Assistance Center Product Management Project Engineering Project Administration Network Design Broadband Design (RF Design and Strand Mapping) Integration Network Testing Network Monitoring (Upstream or Downstream) Power Monitoring Remote Surveillance System Turn-Up and Test Service/Maintenance Agreements Technical Training Product Technology Custom Designed Training Technical Operations Detail Engineering End-to-End Installation Drafting Services 7. CUSTOMER SUPPORT SERVICES 7.01 ADC offers the following customer support services. For calls originating in the U.S.A. or Canada, dial , then request the extension listed. For calls originating outside the U.S.A. or Canada, dial or BCG Technical Assistance Center Technical Information Extension 3475 System/Network Configuration Product Specification Product Application Training Installation and Operation Assistance Troubleshooting and Repair Field Assistance Sales Administration Quotation Proposals Extension 3000 Ordering Delivery General Product Information Product Return Department ADC Return Authorization number and instructions Extension 3000 must be obtained before returning products Product information and service can also be obtained by writing ADC Telecommunications, Inc., 4900 West 78th Street, Minneapolis, Minnesota 55435, U.S.A. Page 11
13 Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. This publication may be verified at any time by contacting ADC s Technical Assistance Center at , extension 3475 (in U.S.A. or Canada) or (outside U.S.A. and Canada), or by writing to ADC Telecommunications, Inc., Attn: Technical Assistance Center, Mail Station #77, 4900 West 78th Street, Minneapolis, MN 55435, U.S.A. 1996, ADC Telecommunications, Inc. All Rights Reserved Printed in U.S.A. Page 12
14 Recommended Procedures for Coaxial Termination Type 728 Cable with BNC and TNC Straight Connectors with Locking Center Conductor This procedure provides the information to select cable, connectors, and the tools needed to terminate coaxial connectors on the coaxial cable at the customer location. TNC COAXIAL CABLE WECO Type 728 Belden 8281 Belden 9231 COAXIAL CONNECTOR BNC-728D TNC-728D BNC-8281D BNC-9231D BNC 4603-A The step-by-step terminating instructions are shown on the reverse side of this procedure. Coaxial Cutter: DSX-3 CCUT COAXIAL CUTTER 8611-A Stripping Tool with Black Stripping Cassette: STC-11B Replacement Black Stripping Cassette: CCS-BLK STRIPPING TOOL 8610-A 8347-A REPLACEMENT BLACK STRIPPING CASSETTE CRIMP CRIMP TOOL DIE Pressmaster WT-1*, WT-2 WD-1/WD-2 Daniels WD-1D/WD-2D * WT-1 is manufacture discontinued A CRIMP DIE CRIMP TOOL 8345-A Crimp Sleeve Dimension:.324 In. Center Pin Crimp Dimension:.042 In A Page 13
15 Step 1 Cut the coax cable to the proper length using the coax cutting tool. Step 2 Slide the crimp sleeve onto the cable, placing it at least 6 inches (15.3 cm) from the end of the cable. The marked end of the crimp sleeve should face away from the cut end of the cable IN (8.74 MM) IN (15.09 MM) IN (2.4 MM) IN (3.96 MM) CENTER CONDUCTOR Step 3 Follow the instruction sheet included with the stripping tool for adjusting the cutting depth of each blade of the stripping cassette. Adjust the blade depths to cut the appropriate layers of the coaxial cable. The blades should not cut beyond the appropriate layer of the coaxial cable. (i.e., The blade that cuts the outer jacket should not cut into the braided shield and the blade that cuts the dielectric should not cut into the center conductor, etc.) Some coaxial cables have a metallic foil shield under the braided shield. This foil shield shall be cut to the same dimension as the braided shield. OUTER JACKET Using the specified stripping tool and black stripping cassette, strip the layers of the coaxial cable. (See diagram.) Step 4 Snip the center conductor so there is a measurement of in. (3.9 mm). Step 5 Place the connector s center pin over the cable s center conductor. Using the specified crimp tool and crimp die, crimp the center pin in place making sure the flange of the center pin butts against the crimp die. To test the crimped center pin, moderately pull on the pin. Step 6 While feeding the center pin through the ferruled end of the connector shell, slide the connector shell onto the cable. The connector shell s ferruled end slides over the dielectric (and foil shield if present) and under the braided shield. Push the cable into the connector shell until the center pin locks into the connector shell. The connector shell should not easily slide off the cable when the center pin is locked into the connector shell. Step 7 Slide the crimp sleeve over the braided shield until it butts against the connector shell. The crimp sleeve will cover approximately inch (3.2 cm) of the cable s outer jacket. None of the braided shield should be exposed between the crimp sleeve and the connector shell. Step 8 Using the specified crimp tool and crimp die, center the die over the crimp sleeve and crimp in place. To test the crimp strength, exert a moderate pull on the connector shell. Using company standard procedures, test for opens or shorts. X X X MARKED END OF CRIMP SLEEVE AWAY FROM CABLE END BRAIDED SHIELD INSULATION (DIELECTRIC) 4403-B 4402-B 4604-A 4605-A 4606-A 4607-A 4608-A 4609-A Page 14 ADC Telecommunications, Inc West 78th Street, Minneapolis, Minnesota In U.S.A. and Canada: Outside U.S.A. and Canada: (612) Fax: (612)
16 Recommended Procedures for Coaxial Termination Type 728 Cable with BNC 90 Degree Plug Connectors This procedure provides the information to select cable, connectors, and the tools needed to terminate coaxial connectors on the coaxial cable at the customer location. This new product uses the same strippers, etc., as the BNC and TNC Straight Plug Connectors. **XXXX** COAXIAL CABLE WECO Type 728 Belden 8281 COAXIAL CONNECTOR BNC-RA-728D BNC-RA-8281D RIGHT ANGLE BNC 4610-A Belden 9231 BNC-RA-9231D The step-by-step terminating instructions are shown on the reverse side of this procedure. Coaxial Cutter: DSX-3 CCUT COAXIAL CUTTER 8611-A Stripping Tool with Black Stripping Cassette: DSX-3 CSTRIP-1 Replacement Black Stripping Cassette: CCS-BLK 8347-A STRIPPING TOOL 8610-A REPLACEMENT BLACK STRIPPING CASSETTE CRIMP TOOL CRIMP DIE Pressmaster WT-1*, WT-2 WD-1/WD-2 Daniels WD-1D/WD-2D * WT-1 is manufacture discontinued A CRIMP DIE CRIMP TOOL 8345-A 4602-A Page 15
17 Step 1 Cut Type 728 Cable for BNC 90 Degree Plug Connectors to the proper length using the coax cutting tool IN (8.74 MM) IN (15.09 MM) IN (2.4 MM) Step 2 Slide the crimp sleeve of the BNC connector onto the cable, placing it in a location at least 6 inches (15.3 cm) from the end of the cable. OUTER JACKET Step 3 Follow stripper instruction sheet included with the stripping tool for adjusting cutting lengths of each element of the coaxial cable. The stripped cable should be as shown in the diagram. Coaxial cable from some suppliers may have an additional metallic shield under the braided shield. This additional shield shall be trimmed back to the same dimension as the outer braiding. (See diagram.) BRAIDED SHIELD IN (3.96 MM) CENTER CONDUCTOR INSULATION (DIELECTRIC) 4402-B 4604-A Step 4 Snip the center conductor so there is a measurement of in. (3.9 mm). Step 5 Place the center contact over the center conductor and crimp in place with the specified crimping tool. Note: Be sure the flange on the center contact butts against the crimping die of the jaw. To test the crimp strength, pull on the center conductor A 4606-A Step 6 Slide the BNC connector over the dielectric and under the braid until it is fully seated against the dielectric. Step 7 Slide the crimp sleeve over the braid until it butts against the BNC connector. The crimp sleeve should cover approximately in. (3.2 mm) of the jacket. No excess shield should be exposed between the sleeve and the body A Step 8 Using the specified crimping tool, center the die over the ferrule and crimp in place. To test the crimp strength, exert a moderate pull on the cable to test the strength and seating of the crimp connection. Using company standard procedures, test for opens or shorts A 4640-A Page 16 ADC Telecommunications, Inc West 78th Street, Minneapolis, Minnesota In U.S.A. and Canada: Outside U.S.A. and Canada: (612) Fax: (612)
18 Recommended Procedures for Coaxial Termination Type 734A Cable with BNC and TNC Straight Connectors with Locking Center Conductor This procedure provides the information to select cable, connectors, and the tools needed to terminate coaxial connectors on the coaxial cable at the customer location. COAXIAL CABLE ADC DSX-CM-1000 WECO Type 734A COAXIAL CONNECTOR BNC-734 TNC-734 Belden YR23922 TNC BNC Belden 1505A GEPCO VPM A The step-by-step terminating instructions are shown on the reverse side of this procedure. Coaxial Cutter: DSX-3 CCUT COAXIAL CUTTER 8611-A Stripping Tool with Black Stripping Cassette: STC-12B Replacement Black Stripping Cassette: CCS-BLK STRIPPING TOOL 8610-A 8347-A REPLACEMENT BLACK STRIPPING CASSETTE CRIMP CRIMP TOOL DIE Pressmaster WT-1*, WT-2 WD-1/WD-2 Daniels WD-1D/WD-2D * WT-1 is manufacture discontinued Crimp Sleeve Dimension:.255 In A CRIMP DIE CRIMP TOOL 8345-A Center Pin Crimp Dimension:.042 In A Page 17
19 Step 1 Cut the coax cable to the proper length using the coax cutting tool. Step 2 Slide the crimp sleeve onto the cable, placing it at least 6 inches (15.3 cm) from the end of the cable. The marked end of the crimp sleeve should face away from the cut end of the cable IN (8.74 MM) IN (15.09 MM) IN (2.4 MM) IN (3.96 MM) CENTER CONDUCTOR Step 3 Follow the instruction sheet included with the stripping tool for adjusting the cutting depth of each blade of the stripping cassette. Adjust the blade depths to cut the appropriate layers of the coaxial cable. The blades should not cut beyond the appropriate layer of the coaxial cable. (i.e., The blade that cuts the outer jacket should not cut into the braided shield and the blade that cuts the dielectric should not cut into the center conductor, etc.) Some coaxial cables have a metallic foil shield under the braided shield. This foil shield shall be cut to the same dimension as the braided shield. OUTER JACKET Using the specified stripping tool and black stripping cassette, strip the layers of the coaxial cable. (See diagram.) Step 4 Snip the center conductor so there is a measurement of in. (3.9 mm). Step 5 Place the connector s center pin over the cable s center conductor. Using the specified crimp tool and crimp die, crimp the center pin in place making sure the flange of the center pin butts against the crimp die. To test the crimped center pin, moderately pull on the pin. Step 6 While feeding the center pin through the ferruled end of the connector shell, slide the connector shell onto the cable. The connector shell s ferruled end slides over the dielectric (and foil shield if present) and under the braided shield. Push the cable into the connector shell until the center pin locks into the connector shell. The connector shell should not easily slide off the cable when the center pin is locked into the connector shell. Step 7 Slide the crimp sleeve over the braided shield until it butts against the connector shell. The crimp sleeve will cover approximately inch (3.2 cm) of the cable s outer jacket. None of the braided shield should be exposed between the crimp sleeve and the connector shell. Step 8 Using the specified crimp tool and crimp die, center the die over the crimp sleeve and crimp in place. To test the crimp strength, exert a moderate pull on the connector shell. Using company standard procedures, test for opens or shorts. X X X MARKED END OF CRIMP SLEEVE AWAY FROM CABLE END BRAIDED SHIELD INSULATION (DIELECTRIC) 4403-B 4402-B 4618-A 4619-A 4620-A 4621-A 4622-A 4623-A Page 18 ADC Telecommunications, Inc West 78th Street, Minneapolis, Minnesota In U.S.A. and Canada: Outside U.S.A. and Canada: (612) Fax: (612)
20 Recommended Procedures for Coaxial Termination Type 734A Cable with BNC 90 Degree Plug Connector This procedure provides the information to select cable, connectors, and the tools needed to terminate coaxial connectors on the coaxial cable at the customer location. This new product, when released, will use the same strippers, etc., as the BNC and TNC Straight Plug Connectors. **XXXX** COAXIAL CABLE ADC DSX-CM-1000 WECO Type 734A COAXIAL CONNECTOR Belden YR23922 BNC-RA-734 Belden 1505A RIGHT ANGLE BNC 4610-A GEPCO VPM2000 The step-by-step terminating instructions are shown on the reverse side of this procedure. Coaxial Cutter: DSX-3 CCUT COAXIAL CUTTER 8611-A Stripping Tool with Black Stripping Cassette: STC-12B Replacement Black Stripping Cassette: CCS-BLK 8347-A STRIPPING TOOL 8610-A REPLACEMENT BLACK STRIPPING CASSETTE CRIMP TOOL CRIMP DIE Pressmaster WT-1*, WT-2 WD-1/WD-2 Daniels WD-1D/WD-2D * WT-1 is manufacture discontinued A CRIMP DIE CRIMP TOOL 8345-A Crimp Sleeve Dimension:.255 In. Center Pin Crimp Dimension:.042 In A Page 19
21 Step 1 Cut Type 734A Cable for BNC 90 Degree Plug Connectors to the proper length using the coax cutting tool. Step 2 Slide the crimp sleeve of the BNC connector onto the cable, placing it in a location at least 6 inches (15.3 cm) from the end of the cable IN (8.74 MM) OUTER JACKET BRAIDED SHIELD IN (15.09 MM) IN (2.4 MM) IN (3.96 MM) CENTER CONDUCTOR INSULATION (DIELECTRIC) 4402-B Step 3 Follow stripper instruction sheet included with the stripping tool for adjusting cutting lengths of each element of the coaxial cable. The stripped cable should be as shown in the diagram. Coaxial cable from some suppliers may have an additional metallic shield under the braided shield. This additional shield shall be trimmed back to the same dimension as the outer braiding. (See diagram.) X X X MARKED END OF CRIMP SLEEVE AWAY FROM CABLE END 4403-B Step 4 Snip the center conductor so there is a measurement of in. (3.9 mm) A Step 5 Place the center contact over the center conductor and crimp in place with the specified crimping tool. Note: Be sure the flange on the center contact butts against the crimping die of the jaw. To test the crimp strength, pull on the center conductor A Step 6 Slide the BNC connector over the dielectric and under the braid until it is fully seated against the dielectric A Step 7 Slide the crimp sleeve over the braid until it butts against the BNC (TNC) connector. The crimp sleeve should cover approximately in. (3.2 mm) of the jacket. No excess shield should be exposed between the sleeve and the body A Step 8 Using the specified crimping tool, center the die over the ferrule and crimp in place. To test the crimp strength, exert a moderate pull on the cable to test the strength and seating of the crimp connection. Using company standard procedures, test for opens or shorts A 4640-A Page 20 ADC Telecommunications, Inc West 78th Street, Minneapolis, Minnesota In U.S.A. and Canada: Outside U.S.A. and Canada: (612) Fax: (612)
22 Recommended Procedures for Coaxial Termination RG59B/U Cable with BNC and TNC Straight Connectors with Locking Center Conductor This procedure provides the information to select cable, connectors, and the tools needed to terminate coaxial connectors on the coaxial cable at the customer location. COAXIAL CABLE Belden 8263 RG59B/U COAXIAL CONNECTOR BNC-59D TNC-59D TNC BNC 4629-A The step-by-step terminating instructions are shown on the reverse side of this procedure. Coaxial Cutter: DSX-3 CCUT COAXIAL CUTTER 8611-A Stripping Tool with Black Stripping Cassette: STC-12B Replacement Black Stripping Cassette: CCS-BLK STRIPPING TOOL A 8347-A REPLACEMENT BLACK STRIPPING CASSETTE CRIMP CRIMP TOOL DIE Pressmaster WT-1*, WT-2 WD-1/WD-2 Daniels WD-1D/WD-2D * WT-1 is manufacture discontinued A Crimp Sleeve Dimension:.255 In. CRIMP DIE CRIMP TOOL 8345-A Center Pin Crimp Dimension:.042 In A Page 21
23 Step 1 Cut the coax cable to the proper length using the coax cutting tool. Step 2 Slide the crimp sleeve onto the cable, placing it at least 6 inches (15.3 cm) from the end of the cable. The marked end of the crimp sleeve should face away from the cut end of the cable IN (8.74 MM) IN (15.09 MM) IN (2.4 MM) IN (3.96 MM) CENTER CONDUCTOR Step 3 Follow the instruction sheet included with the stripping tool for adjusting the cutting depth of each blade of the stripping cassette. Adjust the blade depths to cut the appropriate layers of the coaxial cable. The blades should not cut beyond the appropriate layer of the coaxial cable. (i.e., The blade that cuts the outer jacket should not cut into the braided shield and the blade that cuts the dielectric should not cut into the center conductor, etc.) Some coaxial cables have a metallic foil shield under the braided shield. This foil shield shall be cut to the same dimension as the braided shield. OUTER JACKET Using the specified stripping tool and black stripping cassette, strip the layers of the coaxial cable. (See diagram.) Step 4 Snip the center conductor so there is a measurement of in. (3.9 mm). Step 5 Place the connector s center pin over the cable s center conductor. Using the specified crimp tool and crimp die, crimp the center pin in place making sure the flange of the center pin butts against the crimp die. To test the crimped center pin, moderately pull on the pin. Step 6 While feeding the center pin through the ferruled end of the connector shell, slide the connector shell onto the cable. The connector shell s ferruled end slides over the dielectric (and foil shield if present) and under the braided shield. Push the cable into the connector shell until the center pin locks into the connector shell. The connector shell should not easily slide off the cable when the center pin is locked into the connector shell. Step 7 Slide the crimp sleeve over the braided shield until it butts against the connector shell. The crimp sleeve will cover approximately inch (3.2 cm) of the cable s outer jacket. None of the braided shield should be exposed between the crimp sleeve and the connector shell. Step 8 Using the specified crimp tool and crimp die, center the die over the crimp sleeve and crimp in place. To test the crimp strength, exert a moderate pull on the connector shell. Using company standard procedures, test for opens or shorts. X X X MARKED END OF CRIMP SLEEVE AWAY FROM CABLE END BRAIDED SHIELD INSULATION (DIELECTRIC) 4403-B 4402-B 4630-A 4631-A 4632-A 4633-A 4658-A 4634-A Page 22 ADC Telecommunications, Inc West 78th Street, Minneapolis, Minnesota In U.S.A. and Canada: Outside U.S.A. and Canada: (612) Fax: (612)
24 Recommended Procedures for Coaxial Termination RG59B/U Cable with BNC 90 Degree Plug Connectors This procedure provides the information to select cable, connectors, and the tools needed to terminate coaxial connectors on the coaxial cable at the customer location. This new product, when released, will use the same strippers, etc., as the BNC and TNC Straight Plug Connectors. **XXXX** COAXIAL CABLE Belden 8263 RG59B/U COAXIAL CONNECTOR BNC-RA-59D RIGHT ANGLE BNC 4610-A The step-by-step terminating instructions are shown on the reverse side of this procedure. Coaxial Cutter: DSX-3 CCUT COAXIAL CUTTER 8611-A Stripping Tool with Black Stripping Cassette: STC-12B Replacement Black Stripping Cassette: CCS-BLK 8347-A STRIPPING TOOL 8610-A REPLACEMENT BLACK STRIPPING CASSETTE CRIMP TOOL CRIMP DIE Pressmaster WT-1*, WT-2 WD-1/WD-2 Daniels WD-1D/WD-2D * WT-1 is manufacture discontinued A CRIMP DIE CRIMP TOOL 8345-A Crimp Sleeve Dimension:.255 In. Center Pin Crimp Dimension:.042 In A Page 23
25 Step 1 Cut RG59B/U Cable for BNC 90 Degree Plug Connectors to the proper length using the coax cutting tool. Step 2 Slide the crimp sleeve of the BNC connector onto the cable, placing it in a location at least 6 inches (15.3 cm) from the end of the cable. Step 3 Follow stripper instruction sheet included with the stripping tool for adjusting cutting lengths of each element of the coaxial cable. The stripped cable should be as shown in the diagram. Coaxial cable from some suppliers may have an additional metallic shield under the braided shield. This additional shield shall be trimmed back to the same dimension as the outer braiding. (See diagram.) IN (8.74 MM) OUTER JACKET X X X MARKED END OF CRIMP SLEEVE AWAY FROM CABLE END BRAIDED SHIELD IN (15.09 MM) IN (2.4 MM) IN (3.96 MM) CENTER CONDUCTOR INSULATION (DIELECTRIC) 4402-B 4403-B Step 4 Snip the center conductor so there is a measurement of in. (3.9 mm) A Step 5 Place the center contact over the center conductor and crimp in place with the specified crimping tool. Note: Be sure the flange on the center contact butts against the crimping die of the jaw. To test the crimp strength, pull on the center conductor A Step 6 Slide the BNC connector over the dielectric and under the braid until it is fully seated against the dielectric A Step 7 Slide the crimp sleeve over the braid until it butts against the BNC connector. The crimp sleeve should cover approximately in. (3.2 mm) of the jacket. No excess shield should be exposed between the sleeve and the body A Step 8 Using the specified crimping tool, center the die over the ferrule and crimp in place. To test the crimp strength, exert a moderate pull on the cable to test the strength and seating of the crimp connection. Using company standard procedures, test for opens or shorts A 4640-A Page 24 ADC Telecommunications, Inc West 78th Street, Minneapolis, Minnesota In U.S.A. and Canada: Outside U.S.A. and Canada: (612) Fax: (612)
26 Recommended Procedures for Coaxial Termination Type 735A Cable with BNC and TNC Straight Connectors with Locking Center Conductor This procedure provides the information to select cable, connectors, and the tools needed to terminate coaxial connectors on the coaxial cable at the customer location. TNC COAXIAL CABLE AT&T 735A Comm/Scope COAXIAL CONNECTOR BNC-735D TNC-735D BNC 4641-A The step-by-step terminating instructions are shown on the reverse side of this procedure. Coaxial Cutter: DSX-3 CCUT COAXIAL CUTTER 8611-A Stripping Tool with Black Stripping Cassette: STC-13B Replacement Black Stripping Cassette: CCS-BLK STRIPPING TOOL A 8347-A REPLACEMENT BLACK STRIPPING CASSETTE CRIMP CRIMP TOOL DIE Pressmaster WT-1*, WT-2 WD-1/WD-2 Daniels WD-1D/WD-2D * WT-1 is manufacture discontinued A CRIMP DIE CRIMP TOOL 8345-A Crimp Sleeve Dimension:.178 In. Center Pin Crimp Dimension:.042 In A Page 25
27 Step 1 Cut the coax cable to the proper length using the coax cutting tool. Step 2 Slide the crimp sleeve onto the cable, placing it at least 6 inches (15.3 cm) from the end of the cable. The marked end of the crimp sleeve should face away from the cut end of the cable IN (8.74 MM) IN (15.09 MM) IN (2.4 MM) IN (3.96 MM) CENTER CONDUCTOR Step 3 Follow the instruction sheet included with the stripping tool for adjusting the cutting depth of each blade of the stripping cassette. Adjust the blade depths to cut the appropriate layers of the coaxial cable. The blades should not cut beyond the appropriate layer of the coaxial cable. (i.e., The blade that cuts the outer jacket should not cut into the braided shield and the blade that cuts the dielectric should not cut into the center conductor, etc.) Some coaxial cables have a metallic foil shield under the braided shield. This foil shield shall be cut to the same dimension as the braided shield. OUTER JACKET Using the specified stripping tool and black stripping cassette, strip the layers of the coaxial cable. (See diagram.) Step 4 Snip the center conductor so there is a measurement of in. (3.9 mm). Step 5 Place the connector s center pin over the cable s center conductor. Using the specified crimp tool and crimp die, crimp the center pin in place making sure the flange of the center pin butts against the crimp die. To test the crimped center pin, moderately pull on the pin. Step 6 While feeding the center pin through the ferruled end of the connector shell, slide the connector shell onto the cable. The connector shell s ferruled end slides over the dielectric (and foil shield if present) and under the braided shield. Push the cable into the connector shell until the center pin locks into the connector shell. The connector shell should not easily slide off the cable when the center pin is locked into the connector shell. Step 7 Slide the crimp sleeve over the braided shield until it butts against the connector shell. The crimp sleeve will cover approximately inch (3.2 cm) of the cable s outer jacket. None of the braided shield should be exposed between the crimp sleeve and the connector shell. Step 8 Using the specified crimp tool and crimp die, center the die over the crimp sleeve and crimp in place. To test the crimp strength, exert a moderate pull on the connector shell. Using company standard procedures, test for opens or shorts. X X X MARKED END OF CRIMP SLEEVE AWAY FROM CABLE END BRAIDED SHIELD INSULATION (DIELECTRIC) 4403-B 4402-B 4642-A 4643-A 4644-A 4645-A 4646-A 4647-A Page 26 ADC Telecommunications, Inc West 78th Street, Minneapolis, Minnesota In U.S.A. and Canada: Outside U.S.A. and Canada: (612) Fax: (612)
28 Recommended Procedures for Coaxial Termination Type 735A Cable with BNC 90 Degree Plug Connectors This procedure provides the information to select cable, connectors, and the tools needed to terminate coaxial connectors on the coaxial cable at the customer location. This new product uses the same strippers, etc., as the BNC and TNC Straight Plug Connectors. **XXXX** COAXIAL CABLE AT&T 735A Comm/Scope COAXIAL CONNECTOR BNC-RA-735D RIGHT ANGLE BNC 4610-A The step-by-step terminating instructions are shown on the reverse side of this procedure A Coaxial Cutter: DSX-3 CCUT COAXIAL CUTTER 8611-A Stripping Tool with Black Stripping Cassette: STC-13B Replacement Black Stripping Cassette: CCS-BLK 8347-A STRIPPING TOOL 8610-A REPLACEMENT BLACK STRIPPING CASSETTE CRIMP TOOL CRIMP DIE Pressmaster WT-1*, WT-2 WD-2 Daniels WD-2D * WT-1 is manufacture discontinued A CRIMP DIE CRIMP TOOL 8345-A Crimp Sleeve Dimension:.178 In. Center Pin Crimp Dimension:.042 In A Page 27
29 Step 1 Cut Type 735A cable for BNC 90 Degree Plug Connectors to the proper length using the coax cutting tool IN (8.74 MM) IN (15.09 MM) IN (2.4 MM) Step 2 Slide the crimp sleeve of the BNC connector onto the cable, placing it in a location at least 6 inches (15.3 cm) from the end of the cable. Step 3 Follow stripper instruction sheet included with the stripping tool for adjusting cutting lengths of each element of the coaxial cable. The stripped cable should be as shown in the diagram. Coaxial cable from some suppliers may have an additional metallic shield under the braided shield. This additional shield shall be trimmed back to the same dimension as the outer braiding. (See diagram.) Step 4 Snip the center conductor so there is a measurement of in. (3.9 mm). Step 5 Place the center contact over the center conductor and crimp in place with the specified crimping tool. Note: Be sure the flange on the center contact butts against the crimping die of the jaw. To test the crimp strength, pull on the center conductor. Step 6 Slide the BNC connector over the dielectric and under the braid until it is fully seated against the dielectric. OUTER JACKET Step 7 Slide the crimp sleeve over the braid until it butts against the BNC connector. The crimp sleeve should cover approximately in. (3.2 mm) of the jacket. No excess shield should be exposed between the sleeve and the body. Step 8 Using the specified crimping tool, center the die over the ferrule and crimp in place. To test the crimp strength, exert a moderate pull on the cable to test the strength and seating of the crimp connection. Using company standard procedures, test for opens or shorts. BRAIDED SHIELD IN (3.96 MM) CENTER CONDUCTOR INSULATION (DIELECTRIC) 4402-B 4630-A 4631-A 4632-A 4638-A 4639-A 4640-A Page 28 ADC Telecommunications, Inc West 78th Street, Minneapolis, Minnesota In U.S.A. and Canada: Outside U.S.A. and Canada: (612) Fax: (612)
30 Recommended Procedures for Coaxial Termination Type 0222 Cable with BNC and TNC Straight Connectors with Locking Center Conductor This procedure provides the information to select cable, connectors, and the tools needed to terminate coaxial connectors on the coaxial cable at the customer location. TNC COAXIAL CABLE Comm/Scope 0222 Comm/Scope 0232 GEPCO RGBS809 GEPCO VDFM809 COAXIAL CONNECTOR BNC-0222D TNC-0222D BNC 4641-A The step-by-step terminating instructions are shown on the reverse side of this procedure. Coaxial Cutter: DSX-3 CCUT COAXIAL CUTTER 8611-A Stripping Tool with Black Stripping Cassette: STC-13B Replacement Black Stripping Cassette: CCS-BLK STRIPPING TOOL 8610-A 8347-A REPLACEMENT BLACK STRIPPING CASSETTE CRIMP CRIMP TOOL DIE Pressmaster WT-1*, WT-2 WD-3 Daniels WD-3D * WT-1 is manufacture discontinued A Crimp Sleeve Dimension:.197 In. CRIMP DIE CRIMP TOOL 8345-A Center Pin Crimp Dimension:.042 In A Page 29
31 Step 1 Cut the coax cable to the proper length using the coax cutting tool. Step 2 Slide the crimp sleeve onto the cable, placing it at least 6 inches (15.3 cm) from the end of the cable. The marked end of the crimp sleeve should face away from the cut end of the cable IN (8.74 MM) IN (15.09 MM) IN (2.4 MM) IN (3.96 MM) CENTER CONDUCTOR Step 3 Follow the instruction sheet included with the stripping tool for adjusting the cutting depth of each blade of the stripping cassette. Adjust the blade depths to cut the appropriate layers of the coaxial cable. The blades should not cut beyond the appropriate layer of the coaxial cable. (i.e., The blade that cuts the outer jacket should not cut into the braided shield and the blade that cuts the dielectric should not cut into the center conductor, etc.) Some coaxial cables have a metallic foil shield under the braided shield. This foil shield shall be cut to the same dimension as the braided shield. Using the specified stripping tool and black stripping cassette, strip the layers of the coaxial cable. (See diagram.) Step 4 Snip the conductor so there is a measurement of in. (3.9 mm). OUTER JACKET Step 5 Place the connector s center pin over the cable s center conductor. Using the specified crimp tool and crimp die, crimp the center pin in place making sure the flange of the center pin butts against the crimp die. To test the crimped center pin, moderately pull on the pin. Step 6 While feeding the center pin through the ferruled end of the connector shell, slide the connector shell onto the cable. The connector shell s ferruled end slides over the dielectric (and foil shield if present) and under the braided shield. Push the cable into the connector shell until the center pin locks into the connector shell. The connector shell should not easily slide off the cable when the center pin is locked into the connector shell. Step 7 Slide the crimp sleeve over the braided shield until it butts against the connector shell. The crimp sleeve will cover approximately inch (3.2 cm) of the cable s outer jacket. None of the braided shield should be exposed between the crimp sleeve and the connector shell. Step 8 Using the specified crimp tool and crimp die, center the die over the crimp sleeve and crimp in place. To test the crimp strength, exert a moderate pull on the connector shell. Using company standard procedures, test for opens or shorts. X X X MARKED END OF CRIMP SLEEVE AWAY FROM CABLE END BRAIDED SHIELD INSULATION (DIELECTRIC) 4403-B 4402-B 4642-A 4643-A 4644-A 4645-A 4646-A 4647-A Page 30 ADC Telecommunications, Inc West 78th Street, Minneapolis, Minnesota In U.S.A. and Canada: Outside U.S.A. and Canada: (612) Fax: (612)
DDP-3 Engineering Guide
Issue, May 998 DDP- Engineering Guide Content Page INTRODUCTION... Revision History... List of Changes... Trademark Information... Related Publications... Admonishments.... GERAL... A. Overview of the
More informationJack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes
BNC 75Ω RF CONNECTORS BNC 75Ω RF CONNECTORS To meet the need for higher performance, impedance matched cable interconnections, Amphenol offers a full line of 75 ohm BNC connectors. These connectors can
More informationDigital Link Cross Connect (DLx ) System User Manual
Issue, April 998 Digital Link Cross Connect (DLx ) System User Manual Content Page TRODUCTION... Revision History... Trademark Information... Admonishments... Compliance Statement... Certification... Standards...
More informationUser s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide (60-073-01)
User s Manual BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide (60-073-01) BNC Termination Kit Instructions This document is a compilation of Extron s instructions, together with
More informationCOAXICON Contacts. RF Coax Connectors. Product Facts
COXICON Contacts Product Facts Tyco Electronics provides a variety of contacts for coaxial connectors Contacts are available in a range of sizes that may be used with the various types of coaxial cable
More informationSMA Interface Mating Dimensions (Per MIL-STD-348)
SMA Series SMA 6 SMA Interface Mating Dimensions (Per MIL-STD-348) SMA Interface Dimensions MALE Inches/Millimeters 3 Minimum Nominal Maximum LTR in. mm in. mm in. mm A.250 6.35.263 6.68.. B.1790 4.55.1808
More informationSMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits
INTRODUCTION The Radiall Type 43 coaxial connector range The Radiall range of Type 43 series connectors is fully approved (where applicable) to BT (British Telecom) standards as well as to British Standard
More informationTimes Microwave Systems Hermetically Sealed Assemblies
SCOPE This Specification details the Electrical, Mechanical and Environmental Characteristics of Times Microwave Systems MILTECH 340.34 Diameter Hermetically Sealed Coaxial Transmission Lines. This product
More informationSMA Connectors. RF Coax Connectors. Product Facts
SMA Connectors Product Facts Performance to 12.4 GHz and beyond Available in various base metal options, including stainless steel, brass and zinc diecast Uses industry standard crimp tools and processes
More informationDigital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.
Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip. Each dielectric configuration has different high-frequency characteristics. All configurations
More informationThis paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:
UTP Technology In the late 1970s, unshielded twisted pair (UTP) cabling originated in the computer industry as a means of transmitting digital data over computer networks. This cable was designed to be
More information75 Ω Transmission System
NRAO NTC-DSL Laboratory Report Dynamic Spectroscopy Laboratory Report Series Report 03 September, 2006 75 Ω Transmission System Chaitali R. Parashare Department of Electrical and Computer Engineering,
More informationStandards Affecting a Premise T-1 Installation
Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity
More informationCCTV System Troubleshooting Guide
Wouldn t be nice to start and finish a CCTV System Project without running into any problems before, during and after the installation is completed. Well, in this article we will try and explain why we
More informationULTIMATE SNAP-N-SEAL
ULTIMATE SNAP-N-SEAL F Series Compression Connectors Thomas & Betts introduces the Ultimate Snap-N-Seal Compression Connector, the newest addition to the Snap-N-Seal system. Look for the classic design
More informationUSER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)
USER MANUAL MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun) An ISO-9001 Certified Company Part #07M460-E Doc. #019021UE Revised 02/23/00 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301)
More informationSiemens Energy & Automation. structured. WIRING Product Training Series: Advanced Video Session 3
s structured WIRING Product Training Series: Advanced Video Session 3 1 Table of Contents This presentation will give you a closer look at Video in Structured Wiring applications. The following Areas will
More informationTerminating 25-Pair Cable and 4-Pair Cross Connects
Terminating 25-Pair Cable and 4-Pair Cross Connects Estimated Time: 90 minutes Number of Teams: 2 Number of Team Members: one to four This Lab has four major parts that will be addressed separately. 1.
More informationCoaXPress White Paper WP-2: Cabling Solutions
White Paper Authors Chris Beynon, Active Silicon Ltd Jochem Hermann, Adimec Advanced Image Systems BV Edited By Chris Beynon, Active Silicon Ltd Revision 1.0 27 November 2009 White Paper 1 Introduction...
More informationCurrent Probes. User Manual
Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall
More informationPlanning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER
Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER Questions to Ask When Planning the Cabling Plant Planning a copper cabling plant to support 10Gbps transmission
More informationBalun Bulletin- CCTV Systems- Termination
Balun Bulletin- CCTV Systems- Termination Baluns- CCTV Types 1 Balanced Cables: Category Cables 2 Balanced Cables: V/Cat 3 Connecting Balanced Lines 4 Unbalanced Cables: Coax 5 Connecting Unbalanced Lines
More informationUniversal MATE-N-LOK Connectors
Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00
More informationShielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness
Shielding Effectiveness Test Method Harbour s LL, SB, and SS Coaxial Cables Designs for Improved Shielding Effectiveness Harbour Industries 4744 Shelburne Road Shelburne Vermont 05482 USA 802-985-3311
More informationEMC Test Chamber Solutions RF Cable Assemblies and Connectors
EMC Test Chamber Solutions RF Cable Assemblies and Connectors RF CABLE ASSEMBLY AND CONNECTOR SOLUTONS FOR EMC MMUNTY AND EMSSON COMPLANCE TESTNG E X T N T R A T E D E P T H --> POWER LEVEL: -40.00 dbm
More informationDirectory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
More informationCoaxial Cables for Medium-Frequency Applications
Coaxial Cables for Medium-Frequency Applications Coaxial Cables for Medium-Frequency Applications Introduction Telecommunications technology is moving forward rapidly and the need for fast and reliable
More informationThe Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling
More informationCat7/Class F New Installation Concept New infrastructure. Handbook
Cat7/Class F New Installation Concept New infrastructure Handbook contents 1 Introduction 3 2 What is the Cat7/Class F installation concept 3 3 Distribution centre 3 3.1 Patch Modules 3 4 How to handle
More informationCable Analysis and Fault Detection using the Bode 100
Cable Analysis and Fault Detection using the Bode 100 By Stephan Synkule 2014 by OMICRON Lab V1.3 Visit www.omicron-lab.com for more information. Contact support@omicron-lab.com for technical support.
More informationLOW LOSS CABLE PAG. 1
LOW LOSS CABLE PAG. 1 INTRODUCTION Following many requests we received regarding the need for low-loss custom cable assemblies, we have set up a special production of high performance coaxial cable assemblies
More informationI-PEX MHF4 Micro Coaxial Connector
PRODUCT SPECIFICATION I-PEX MHF4 Micro Coaxial Connector Plug P/N 20448-001R-81 Receptacle P/N 20449-001E RF Connector, RF Cable & Antenna Manufacturer E-mail: sales@wellshow.com.tw Tel: +886-2-24239376
More informationPrecision Miniature Load Cell. Models 8431, 8432 with Overload Protection
w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force
More informationET plus Antenna Amplifier 03/20/06
INSTALLATION TIP: CB_032006 ET plus Antenna Amplifier 03/20/06 Products: Versions: ET plus Series 9,12, 18 & 24 stations All Software Versions Overview This Installation Tip identifies how to install an
More informationMICRO SFP+ CONNECTOR & CABLE ASSEMBLY
MICRO SFP+ CONNECTOR & CABLE ASSEMBLY micro SFP+ Connector and Cable Assembly TE Connectivity s (TE) micro SFP+ connector and cable assembly empower you to dream big when designing your communication system.
More informationOn Cables and Connections A discussion by Dr. J. Kramer
KRAMER ELECTRONICS LTD. On Cables and Connections A discussion by Dr. J. Kramer We are frequently asked - "what length of cable can I use for a specific application?" Seemingly a simple question, but the
More informationApplication Guide to RF Coaxial Connectors and Cables
Application Guide to RF Coaxial Connectors and Cables By: Michael J. Hannon Product Applications Engineer and Pat Malloy, Sr. Applications Engineer There is a wide variety of coaxial connectors and cables
More informationTHERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
More informationUnarmored Variable Frequency Drive (VFD) Cable Termination Guide
Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored
More informationSPIR-110: U of S RG174 Cable Assembly for CAEN 792AA QDC
SPIR-110: U of S RG174 Cable Assembly for CAEN 792AA QDC Ward Wurtz and Ru Igarashi 28th August 2003 Contents 1 Introduction 2 2 Diagrams 2 3 Assembly Instructions 5 3.1 Measuring and Cutting Cable...............................
More informationDynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer
3 Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer DSL User s Guide Future-Proof Testing Platform February 2009 78-8140-2658-5-A 2 3M Dynatel Advanced Modular System 965AMS 30-MHz
More informationCable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection
Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification
More information400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
More informationSMA Waterproof. Cable Assembly. Filtered Audio Connector. Dataport Receptacle. Dataport Plug
INTERCONNECT SOLUTIONS FOR RUGGEDIZED COMMUNICATIONS GPS Antenna Gooseneck Adapter TNC Waterproof Cable Assembly Communication radios often carry critical public safety information and must operate reliably
More informationNexus Technology Review -- Exhibit A
Nexus Technology Review -- Exhibit A Background A. Types of DSL Lines DSL comes in many flavors: ADSL, ADSL2, ADSL2+, VDSL and VDSL2. Each DSL variant respectively operates up a higher frequency level.
More informationRX-AM4SF Receiver. Pin-out. Connections
RX-AM4SF Receiver The super-heterodyne receiver RX-AM4SF can provide a RSSI output indicating the amplitude of the received signal: this output can be used to create a field-strength meter capable to indicate
More informationAntenna Splitter ASA 1. Instruction manual
Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...
More informationCables. Indoor, Outdoor, HDMI, CAT, connectors. Cables, connectors and tools
Indoor, Outdoor, HDMI, CAT, connectors, connectors and tools Indoor Outdoor Fly leads HDMI CAT F -/IEC connectors F -/IEC adaptors F - terminator Connection cables Power cables and electricity articles
More informationSubminiature Load Cell Model 8417
w Technical Product Information Subminiature Load Cell 1. Introduction... 2 2. Preparing for use... 2 2.1 Unpacking... 2 2.2 Using the instrument for the first time... 2 2.3 Grounding and potential connection...
More informationLocoNet, the Digitrax Difference
LocoNet, the Digitrax Difference LocoNet is Digitrax's method of communication between LocoNet compatible devices on a model railroad layout. LocoNet Compatible devices are designed to work together on
More informationLynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)
Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages) 1. Be sure that your kit includes all the parts shown in the Check the Equipment section
More informationcoaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable
COAXIAL CABLE coaxial Cable 100% certified coaxial cable coaxial cable CERTIFIED The step ahead undertaken by Televés to improve its service and technical excellence, is now reflected in this new challenge.
More informationAn Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware
for CAT 6A Connecting Hardware Written by: Antoine Pelletier Engineer, Global Cabling Products Intertek www.intertek-etlsemko.com 1-800-WORLDLAB Introduction The telecommunication industry recently achieved
More informationTechnical Note. HDTV-SDI Cabling Material Selection. HD-SDI Distribution : Introduction canare.com. Cabling Material Selection
HD-SDI Distribution : Introduction HD-SDI Distribution : Introduction canare.com HDTV-SDI Cabling Material Selection Broadcast stations and postproduction studios in many countries around the world are
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 123 2011
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 123 2011 Specification for F Connector, Male, Feed-Through NOTICE The Society of Cable Telecommunications Engineers
More informationNetwork Design. Yiannos Mylonas
Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which
More informationPRODUCTS SPECIFICATION
PRODUCTS SPECIFICATION ************************************************************************************** Description : DVI Connector Customer : COMOSS P/N : DV Series Date of Issue : 20-Sep-2002 Version
More informationSHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS
STRUCTURED CABLING SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS INTRODUCTION In recent years, communications have taken on a crucial role in development for businesses. Communications
More informationRF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.
Receiver AC-RX2/CS RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. Pin-out 38.1 3 Component Side 1 2 3 7 11 13 14 15
More informationRF cables. Edition 2015
RF cables Edition 2015 Developed for highest expectations Your partner for system solutions HUBER+SUHNER is a leading international producer and supplier of electrical and optical interconnectivity components
More informationPRODUCT SPECIFICATION
ipass TM / ipass+ TM 0.8 mm PITCH I/O CONNECTOR SYSTEM EXTERNAL ipass / ipass+ of TABLE OF CONTENTS.0 SCOPE... 3.0 PRODUCT DESCRIPTION... 3. PRODUCT NAME AND SERIES NUMBER(S)... 3. DIMENSION, MATERIALS,
More informationMarine HF SSB Installation and Grounding. Anatomy of the Best Tour 2006
Marine HF SSB Installation and Grounding Anatomy of the Best Tour 2006 Marine HF Installation Considerations This document is meant to be an overview of Marine HF radio installation For detailed installation
More informationUniprise Solutions COAX 101. White Paper. www.commscope.com
Uniprise Solutions COAX 101 White Paper www.commscope.com Structured cable systems have very thorough standards for fiber optic and twisted pair installations. The cabling components and installed systems
More informationspinner Measurement & Calibration equipment for network analyzers
spinner Measurement & Calibration equipment for network analyzers Edition B 2011 High Frequency Performance Worldwide www.spinner-group.com SPINNER test & calibration equipment for best measurement results
More informationInstallation instructions for Series NRX INCOM communications adapter module
4000 NRX RF DRAWOUT SUBTITLE IMAGE (12/15/2010) Effective July 2015 Supersedes October 2010 IL01301033EH04 Installation instructions for Series NRX INCOM communications adapter module Instructions apply
More informationIRT Eurocard. Types DAX-3200
I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9489 3744 Fax: (02) 9439 7439 International: +61 2 9439 3744 +61 2 9439 7439 Email:
More informationVideo Camera Installation Guide
Video Camera Installation Guide The intent of this guide is to provide the information needed to complete or modify a video camera installation to avoid lightning and induced power surge damage. This guide
More informationTransformer-coupled passive transmit path with a fixed insertion loss of approximately 1.0dB.
Charles Industries, Ltd. Section 319 29P 201 Equipment Issue 1 Second Printing, August 1999 STS 3192 9P Short Loop Office Repeater CONTENTS Complies with UL Standard 1459 Second Edition. PAGE Part 1. GENERAL.............................................................................
More informationUniStream CPU-for-Panel
UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic
More informationCable 101. A Broadband Telecommunications Primer for Non-technical Personnel
Cable 101 KnowledgeLink, Inc. A Broadband Telecommunications Primer for Non-technical Personnel Presented by: Justin J. Junkus President, KnowledgeLink, Inc. November 20, 2013 Agenda Broadband Cable Systems
More informationSECTION 16715 TELECOMMUNICATIONS ACCEPTANCE TESTING
PART 1 - GENERAL 1.1 SECTION INCLUDES A. Testing Publications and Standards B. Inspection and testing procedures for copper and fiber optic cable, RF CATV / MATV systems, and the antenna systems. C. Documentation
More informationCable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range
HONEYWELL SECURITY & CUSTOM ELECTRONICS Cable Products Honeywell's Genesis Series provides a full range of low voltage cables for security, fire, sound, voice and data, video, structured cabling and other
More information1. ANSI T1.102-1993 T1
AN7 Application Note Measurement and Evaluation of Pulse Shapes in T1/E1 Transmission Systems By Roger Taylor Crystal Semiconductor Corporation P.O. Box 17847, Austin, TX 78760 (512) 445-7222 FAX: (512)
More informationHDMI Fiber Optic Cable. DVI-D Fiber Optic Cable. User Guide
HDMI Fiber Optic Cable DVI-D Fiber Optic Cable User Guide 1. Product Description Thank you for purchasing this HDMI Fiber Optic Cable. This cable is capable of transmitting digital HDMI (or DVI) signals
More informationAN1200.04. Application Note: FCC Regulations for ISM Band Devices: 902-928 MHz. FCC Regulations for ISM Band Devices: 902-928 MHz
AN1200.04 Application Note: FCC Regulations for ISM Band Devices: Copyright Semtech 2006 1 of 15 www.semtech.com 1 Table of Contents 1 Table of Contents...2 1.1 Index of Figures...2 1.2 Index of Tables...2
More information3M Integrated Splitter Block BRCP-SP
The Network of Networks 3M Integrated Splitter Block BRCP-SP The 3M Integrated Splitter Block BRCP-SP is the latest generation of the Cross Connect System BRCP developed by 3M specifically for xdsl and
More informationF2400 FOM II Series Fiber Optic Modem Technical Manual
F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data
More informationDIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
More informationSignal directionality Lower frequency signals are omnidirectional Higher frequency signals can be focused in a directional beam
Transmission Media Transmission medium Physical path between transmitter and receiver May be guided (wired) or unguided (wireless) Communication achieved by using em waves Characteristics and quality of
More informationComputers Are Your Future. 2006 Prentice-Hall, Inc.
Computers Are Your Future 2006 Prentice-Hall, Inc. Computers Are Your Future Chapter 3 Wired and Wireless Communication 2006 Prentice-Hall, Inc Slide 2 What You Will Learn... ü The definition of bandwidth
More informationRF Connector Solutions
RF Connector Solutions C o n n e c t i n g I n n o v a t i o n t o A p p l i c a t i o n Winchester Electronics was established in 1941 and is today a global leader in the design, development, and deployment
More informationAmplified High Speed Fiber Photodetectors
Amplified High Speed Fiber Photodetectors User Guide (800)697-6782 sales@eotech.com www.eotech.com Page 1 of 7 EOT AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE Thank you for purchasing your Amplified
More informationTest Cable Assemblies
Test Cable Assemblies and Coaxial Passive Components DC-65 GHz 8851 SW Old Kansas Ave. Stuart, FL 34997 USA +1-772-286-9300 +1-800-544-5594 sales@emc-rflabs.com www.emc-rflabs.com Premium Test Cable Lab-Flex
More informationData Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B
CSE 3461 / 5461: Computer Networking & Internet Technologies Data Transmission Presentation B Kannan Srinivasan 08/30/2012 Data Communications Model Figure 1.2 Studying Assignment: 3.1-3.4, 4.1 Presentation
More information6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding
circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),
More informationThe Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT
The Effect of Network Cabling on Bit Error Rate Performance By Paul Kish NORDX/CDT Table of Contents Introduction... 2 Probability of Causing Errors... 3 Noise Sources Contributing to Errors... 4 Bit Error
More informationCoaxial Cable Products Guide. Connectivity for Business-Critical Continuity
Coaxial Cable Products Guide Connectivity for Business-Critical Continuity The Difference Starts With The Cable BULK CABLES SLA Series Lowest loss cable available to 18 GHz, best choice for critical applications
More informationWHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications
WHITEPAPER Cable and Connector for Hiperface dsl motor drive applications information for cable manufacturers Version 02 Content Information for cable manufacturers...3 Communication...3 Crosstalk & shielding...3
More informationHP 8970B Option 020. Service Manual Supplement
HP 8970B Option 020 Service Manual Supplement Service Manual Supplement HP 8970B Option 020 HP Part no. 08970-90115 Edition 1 May 1998 UNIX is a registered trademark of AT&T in the USA and other countries.
More informationPCb Cable mount twinax. ConneCtorS
PCb Cable mount twinax ConneCtorS technical CharaCteriStiCS SPeCiFiCationS temperature rating: -55 C to + 125 C Corrosion: MIL-STD-202 Method 101, Test Condition B Shock: MIL-STD-202 Method 213, Test Condition
More informationStandard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
More information114-22008. 8-Position Cat5e (EMT) Modular Plug Connectors. Application Specification
Application Specification 114-22008 02/May/2008 Rev H 8-Position Cat5e (EMT) Modular Plug Connectors NOTE All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are
More informationOutside Plant DS3 Deployment Connectivity Hardware TROMPETER
Outside Plant DS3 Deployment Connectivity Hardware TROMPETER E L E C T R O N I C S, I N C. 3G -WIRELESS PASS THRU JACK MODULE WITH NON-INTRUSIVE SIGNAL MONITORING PORTS One of the problems involved with
More informationVideo Security Systems Technician
Video Security Systems Technician Level I Certification Content Outline National Institute for Certification in Engineering Technologies Introduction The purpose of this certification program is to recognize
More informationLT-82 Stationary IR Transmitter
LT-82 Stationary IR Transmitter Configuration LT-82-0 (North America) LT-82-02 (Asia, UK) LT-82-03 (Euro) The Listen LT-82 is the heart of a stationary IR listening system. It takes the desired audio signal
More informationTIMING SIGNALS, IRIG-B AND PULSES
TIMING SIGNALS, IRIG-B AND PULSES Document No. PD0043200B July 2013 Arbiter Systems, Inc. 1324 Vendels Circle, Suite 121 Paso Robles, CA 93446 U.S.A. (805) 237-3831, (800) 321-3831 http://www.arbiter.com
More informationSICK AG WHITEPAPER. Information for cable manufacturers Note-2_03
SICK AG WHITEPAPER Cable and connector for HIPERFACE DSL motor drive applications Information for cable manufacturers Note-2_03 Juergen Funkhaenel Application Engineer at SICK STEGMANN GmbH Donaueschingen
More informationDIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)
Features: DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) PATENT NUMBERS: CANADA 2,494,133, USA 7095931, 7295731 AND CHINA 1672073 Telcordia GR-468 qualified Available in versions for any wavelength
More informationTechnical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
More informationTELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual
TELIKOU Intercom System MS-500(4+1 channel) Main Station Instruction Manual TELIKOU Systems All Rights Reserved While TELIKOU makes every attempt to maintain the accuracy of the information contained in
More information