PowerBox PBX 180. Installation and Users Guide
|
|
|
- Clare Irma Daniel
- 9 years ago
- Views:
Transcription
1 PowerBox PBX 180 Installation and Users Guide Firmware and Tool Version 060 7/14/2015
2 Table of Contents Table of Contents 1 Introduction Hardware Software Installation Software Installation from a CD Software Installation from web-download PC Software and Firmware Releases Connection to System Wiring Harness Main Menu File Device Interface Options Help Functions Overview Units Events Miscellaneous Special Functions Counters Status Events Monitor Output Diagnostics Inputs Digital Inputs Analogue Inputs CAN Inputs Outputs Tri-State Outputs Low Power Outputs Low Power PWM Outputs High Power Outputs Very High Power High Power PWM Outputs Sensor Supplies Wiper Outputs Warning Lamp Fault Reset CAN Bus Data Bus CAN Monitor CAN Export / 60 PowerBox PBX 180 Bosch Motorsport
3 Table of Contents 9 Pin Configuration Connector 1 - Battery Power Supply Connector 2 - High Power Outputs Connector 3 - Low Power Outputs Connector 4 - Signal and Inputs Specifications Inputs Outputs Maximum Current Rating Temperatures Communication Power Supply Dimensions Bosch Motorsport PowerBox PBX / 60
4 1 Introduction 1 Introduction The Bosch PowerBox PBX 180 takes the whole Power Control Module concept much further than existing modules. It provides an effective and inspired alternative to conventional relays, circuit breakers, fuses and wires that can so often be a tangle of complexity and untidiness around a typical racing car s power junction box. Bosch PowerBox PBX 180 is a compact and light weight module, measuring 191 x 176 x 36 mm (excluding the Autosport connectors). Bosch PowerBox PBX 180 has a maximum of 48 power channels, arranged as: 26 normal power channels, each 8 A continuous power supply. 2 normal and wiper motor power channels, each 8 A continuous power supply. 4 low power channels with PWM, each 8 A continuous power supply. 12 high power channels, each 20 A continuous power supply. 2 high power channels with PWM, each 20 A continuous power supply. 2 very high power channels, each 20 A continuous power supply. All outputs are protected against reversed battery polarity. Current draw can be measured on all 48 power channels: From 50 ma on 4 low power channels. From 200 ma on all other channels. Any of these channels can be controlled by various types and combinations of inputs: 14 digital inputs with automatic sensing of high, low and floating potential. 16 analogue 0 to 12 V sensor inputs with 16 bit resolution. 64 individually programmable CAN inputs, 11 or 29 bit identifiers, with bit operator. 4 individually programmable CAN busses. Bosch PowerBox PBX 180 is also equipped with 4 tri-state outputs. A tri-state output is only for use as an ECU trigger. Do not connect any of these four channels to any output load. In addition to the 4 CAN bus, Bosch PowerBox PBX 180 is also equipped with a LIN bus. Bosch PowerBox PBX 180 can be configured as either a LIN bus master or slave. Use the LIN bus for example to control the alternator charge current or to control the wiper motor. Instead of using a conventional control program, Bosch PowerBox PBX 180 benefits from a multi-tasking operating system, allowing simultaneous executions of operations. Furthermore, Bosch PowerBox PBX 180 is equipped with a real time clock and also has a built-in data recording facility with a memory capacity of minimum 2 GB. Data is downloaded via the Ethernet connection. 4 / 60 PowerBox PBX 180 Bosch Motorsport
5 Introduction 1 Please note that the maximum recommended current draw per channel is limited by the connector contacts - not by Bosch PowerBox PBX 180s driver stages. We have rated the individual channel s current draw in relation to the connector manufacturer s specifications. Bosch PowerBox PBX 180 is programmed to shut overloaded channels down if the current draw and internal junction temperatures exceed pre-set levels. Board temperatures are monitored and can be exported via CAN. For normal running conditions, the user can set limits for inrush current level and time; the fused thresholds for continuous current draw plus the number of retries and retry time intervals for each output channel. A manual reset function of all overloaded channels is also available. The current draws and channel status can be logged internally and exported via one of the four available CAN bus. Please note that the PCM is not intended to be used to control safety-critical systems on a vehicle, such as ABS braking, power steering, etc. Bosch Motorsport shall not be responsible for any incidental or consequential damages or injuries that may occur if the unit is used to control these, or similar, safety-critical systems. Bosch Motorsport PowerBox PBX / 60
6 2 Hardware 2 Hardware The Bosch PowerBox PBX 180 enclosure is CNC machined to the highest standards. The two parts of the casing are sealed by an O-ring, located in a recess in the main half. A lip in the lid presses on the O-ring and assures a water tight sealing. The connectors are individually sealed. Connector #1 is a Deutsch Autosport Heavy Duty single pin connector, type ASHD PN. This is a specially developed connector, designed to conduct very high currents with very low losses and to withstand high temperatures. We recommend using a 35 sq.mm heavy duty battery cable as the main power supply. The mating connector on the wiring loom must be ASHD S C35. Connector #2 is a Deutsch Autosport connector, type AS SN. This connector has 16 size AWG 16 contacts and each contact is designed to handle a maximum current of 20 A. The mating connector on the wiring loom must be AS PN. Connector #3 is a Deutsch Autosport connector, type AS SA. It has a different keyway to connector 2, preventing incorrect mating of connectors. This connector has 37 size AWG 20 contacts and 2 size AWG 16 contacts. Each AWG 20 contact is designed to handle max 8 A current. The two size AWG 16 contacts (pins m and r) in this connector are power ground connections and must be connected to earth. The mating connector on the wiring loom must be AS PA (yellow coding). Connector #4 is a Deutsch Autosport connector, type AS SN. This connector has 55 size AWG 22 contacts and is used for signal, sensor supplies and data connections. The mating connector on the wiring loom must be AS PN. 6 / 60 PowerBox PBX 180 Bosch Motorsport
7 Software Installation Software Installation The software can be installed either from a software CD, provided with the Bosch PowerBox PBX 180 or downloaded from our web site Software Installation from a CD Place the CD in your PC s CD drive. The installation starts automatically. Follow the instructions given on-screen to complete the installation. A manual installation is possible by exploring the installation CD and double clicking on the file called SETUP Bosch PowerBox PBX 180 vx_yz.exe where X_YZ refers to the software release version. 3.2 Software Installation from web-download It is possible to download the Bosch PowerBox PBX 180 software from our web site. Go to and select the Software tab. When you have downloaded the Bosch PowerBox PBX 180 software, open the folder where you saved the file and double click on the installation file. This file is called SETUP Bosch PowerBox PBX 180 vx_yz.exe where X_YZ refers to the software release version. 3.3 PC Software and Firmware Releases Each new release of Bosch PowerBox PBX 180 firmware requires an updated, specific PC tool release. Each new release of the PC tool is backwards compatible, meaning that it will support earlier Bosch PowerBox PBX 180 firmware releases. 3.4 Connection to System Communication between the PC tool and a Bosch PowerBox PBX 180 is established via any of the 4 available CAN connections, using a USB CAN interface. Connection is automatic; no user commands are normally required. Three different versions of interfaces can be used: CAN USB Adapter (Lawicel) Peak CAN Adapter (Peak Systems, recommended) EFI Technology CAN Adapter If you disconnect from the system, communication will be re-established when you plug the cable in again. Bosch Motorsport PowerBox PBX / 60
8 3 Software Installation 3.5 Wiring Harness Bosch Motorsport can supply complete, custom made wiring harnesses for bespoke installations. Our harnesses are manufactured by specialists, using only the best suitable materials for use in the harsh environment of a modern racing or rally car. 8 / 60 PowerBox PBX 180 Bosch Motorsport
9 Main Menu 4 4 Main Menu The PC tool has five main menu sections: File Device Interface Options Help File You can open an existing configuration file by clicking on FILE and then select OPEN. Use F2 as a hot key to open a new configuration file. You can save a configuration file on your PC by clicking on FILE, then SAVE. Now select the folder where you want to save the file, type a file name and click OK. Use F3 as a hot key to save a configuration file. Click on Save Hex to save a configuration file as a hex file. Use F4 as a hot key for this function. Admin is a Bosch PowerBox PBX 180 section only. Click on EXIT to close the Bosch PowerBox PBX 180 tool. Use F7 as a hot key to close the program. Device Read You can read the Bosch PowerBox PBX 180 configuration file by clicking on READ in the menu DEVICE. Use F8 as a hot key to read the configuration from Bosch PowerBox PBX 180. Bosch Motorsport PowerBox PBX / 60
10 4 Main Menu Write You can upload a new configuration from the PC tool to Bosch PowerBox PBX 180 by clicking on WRITE. Use F9 as a hot key to write a new configuration file to Bosch PowerBox PBX 180. Once the new configuration file has been transmitted to the Bosch PowerBox PBX 180, the module is re-booted automatically. Note that a configuration file can only be uploaded if the battery supply voltage is above 10 V. It is not possible to send a configuration file to Bosch PowerBox PBX 180 if more than one event controls a single output. Please see section 5.3. Reset Use F10 as a hot key to re-boot the Bosch PowerBox PBX 180, reading the new settings. Bosch PowerBox PBX 180 is automatically reset after a firmware update or after uploading a new configuration. Firmware Click on FIRMWARE to update the Bosch PowerBox PBX 180 firmware. Once the firmware has been transmitted, Bosch PowerBox PBX 180 performs an automatic re-boot. A new firmware includes new Bosch PowerBox PBX 180 features and it is essential that you also update your PC tool, too. The latest PC toll released is always backwards compatible. Use F6 as a hot key to update firmware. Manual Output Mode Manual Output Mode is used to check the switching and current draw of any output, manually controlled by the PC tool. When power is applied to Bosch PowerBox PBX 180 it starts by default in automatic mode. In Manual Output Mode all events are deactivated and no automatic or programmed switching is possible. Instead, it is only possible to switch each single output ON and OFF using the PC tool. Go to section OUTPUTS for further information. Automatic Output Mode By clicking Automatic Output Mode Bosch PowerBox PBX 180 is switched back into automatic mode. Automatic mode is also re-established if the PC tool is disconnected from the Bosch PowerBox PBX 180. Manual Output Mode, Keep Current States When this option is selected, Bosch PowerBox PBX 180 is in manual operating mode, but keeps its setting from the instant when it is switched into manual mode. Any output which were switched on, remains on in this mode, but can be switched off manually if required. 10 / 60 PowerBox PBX 180 Bosch Motorsport
11 Main Menu Get Time Click Get Time to read date and time from Bosch PowerBox PBX 180 s real time clock. Set Time Click Set Time to update Bosch PowerBox PBX 180 s real time clock with the date and time from the PC connected. Ensure that your PC clock has the required time. Reset Output Counters Click this option to reset all diagnostic counters and error messages. Interface Click Interface and then select the USB-CAN interface in use. Once the right interface is selected, communication will be established between Bosch PowerBox PBX 180 and the PC tool. No other action is required. These interfaces are currently supported: CAN USB Adapter (Lawicel) Peak CAN Adapter (Peak Systems, recommended) EFI Technology CAN Adapter Status of Bosch PowerBox PBX 180 communication is displayed in the tool by a colored LED in the upper right hand corner: Purple: No or incorrect interface connected. Red: No CAN communication. Green: CAN communication OK. 4.4 Options Reset Display on Disconnect Tick this option to retain display information on display screens when disconnecting from Bosch PowerBox PBX 180. This can be a help, for example, in detecting and understanding a possible malfunction. Bosch Motorsport PowerBox PBX / 60
12 4 Main Menu Sync Time Automatically Tick this option to synchronize the time and date between Bosch PowerBox PBX 180 and the PC. 4.5 Help Click HELP to open the Bosch PowerBox PBX 180 help file. Use F1 as a hot key to open the help file. (Feature not implemented in this release). 12 / 60 PowerBox PBX 180 Bosch Motorsport
13 Functions 5 5 Functions The Bosch PowerBox PBX 180 PC tool is divided into sub sections. When the program opens, it displays the Overview section by default. 5.1 Overview This section displays the following Bosch PowerBox PBX 180 information: Serial Number Bosch PowerBox PBX 180 production serial number Intended Serial Number The actual configuration can only be used with a Bosch PowerBox PBX 180 having this serial number. Hardware version Bosch PowerBox PBX 180 hardware release version Power Box Name Reference name for actual PowerBox. Maximum 15 characters can be used. The PC tool release version is also displayed in this section, see Configuration Utility Version. 5.2 Units Use this section to assign a unit to analogue and CAN channels. These settings can be applied in INPUTS, sections Analogue Inputs and CAN Inputs. Bosch Motorsport PowerBox PBX / 60
14 5 Functions Events Bosch PowerBox PBX 180 is controlled by configurable events. Events are used to create conditions, simple as well as complex logic conditions. For example, an output can be controlled by a single event or by a complex string of events. 512 individual events are available and each can be defined as a specific type: For example, a digital input can switch a single output using a single event, or by a complex string of events. Please note that an output must be controlled by a single event. Event Type Select between the following types of control strategies. Input follow Name the event to make it easy to trace it later. Select the input trigger for the event. Set the conditions for switching between true and false. For example, selecting a digital input, the event is ON when the switch is ON. It is OFF when the digital switch is OFF. Select the output to trigger. Select NONE if this is a conditional event only. Input toggle Name the event to make it easy to trace it later. Select the input trigger for the event. Set the conditions for switching between true and false. For example, selecting a digital input, the event will switch ON when the switch is pressed momentary ON. It will switch OFF when the digital switch is pressed again momentary. Select the output to trigger. Select NONE if this is a conditional event only. 14 / 60 PowerBox PBX 180 Bosch Motorsport
15 Functions 5 AND gate The AND gate combines up to five events to set switching conditions. All added events have to be true for the final event to be true. Select the output to trigger. Select NONE if this is a conditional event only. OR gate The OR gate combines up to five events to set switching conditions. Any of the added events have to be true for the final event to be true. Select the output to trigger. Select NONE if this is a conditional event only. NOR gate The NOR gate combines up to five events to set switching conditions. If any of the added events are true, the final event will be false. Select the output to trigger. Select NONE if this is a conditional event only. XOR gate The XOR gate combines up to five events to set switching conditions. When one and only one of the added events are true, the final event will be true. Select the output to trigger. Select NONE if this is a conditional event only. NOT gate The NOT gate inverts a single input event. Select the output to trigger. Select NONE if this is a conditional event only. Flash Defining a flash event it is possible to set: Time ON (how long time is the output switched ON) Time OFF(how long time is the output switched OFF) Initial status, ON or OFF (Flash starts with output switched ON or OFF) Select the output to trigger. Select NONE if this is a conditional event only. Delay input ON Using this event it is possible to set a delay timer for switching the event to true. Delay input OFF Using this event it is possible to set a delay timer for switching the event from true to false. Counter This event is currently not activated. Sequence counter This event is currently not activated. Bosch Motorsport PowerBox PBX / 60
16 5 Functions Reset Use this event to define a reset function for output channels. The reset function will restart outputs which are in a fault status only. No other channels are influenced. The reset function can be used with any input or output and any channel status or current draw. A typical installation combines the fault warning light and a reset switch. Bosch PowerBox PBX 180 has a dedicated output for a fault warning light. Pin 42 in connector #4 provides a 5 V signal out in case one of the output channels goes into a fault mode. It is recommended to use a LED with a 1 kohm resistor in-line as a warning light. Our normal reset function is based on grounding this warning light signal when ON. We can supply a combined switch and a 5 V LED warning light. Creating a Reset event, proceed this way: Select RESET as an even type. Name the event, for example RESET. Select Fault Warning Lamp as source input Set Turn ON as >1 Set Turn OFF as < 2 Refer to section Output Diagnostics for fault message codes. Clock Use this event to link the switching to the real time clock. Always ON Use this event to switch the event to true once power is applied to the Bosch PowerBox PBX 180, for example when the master switch is ON. Tri-state output The tri-state outputs are used as triggers for external systems. Their value can change between 0 V, 2.5 V and 5.0 V. Do not expose these outputs to any load, they are trigger channels only. Please note that if both selectable trigger events (A and B) are true, the output will be 5 V. 16 / 60 PowerBox PBX 180 Bosch Motorsport
17 Functions 5 Wiper output Two dedicated wiper channels are available. These channels are fitted with braking diodes, ensuring the wipers stop when the park signal is detected. Create an event for the park signal. The park signal can be either a ground or battery power signal. Import this event as the Stop event. Select an input to trigger the wiper. When this input is switched OFF, the wiper motor will continue running until the park signal is detected. Event Flash Use this function if an event is required to trigger the flash function. Event Delay On Use this function if it is required to delay switching an event controlled output ON. Event Delay Off Use this function if it is required to delay switching an event controlled output OFF. Bosch Motorsport PowerBox PBX / 60
18 5 Functions Event Wiper The wiper function can also be controlled by an event instead of a direct input as before. Using this function makes it possible to combine wiper strategies, for example combining the wipe wash and wipe delay with normal wiper function Event Name Name the event for easy identification Source Input Select the input controlling this event. Inputs can be: Digital inputs Analogue inputs Current draws Fault status CAN inputs (from all four CAN bus) (CAN bus 1+2 only implemented in this version) Counters Temperature CAN Inputs Lost CAN Action For safety reasons it is possible to set conditions for channels controlled via CAN. If the CAN bus communication is lost at any time for a defined time interval (in milliseconds) the following actions can be defined, individually for each CAN event: Do nothing (keep current status) 18 / 60 PowerBox PBX 180 Bosch Motorsport
19 Functions 5 Turn Off (switch the output channel off) Turn On (switch the output on) CAN Lost Timer This defines a time interval for receiving CAN messages. If a given CAN message is not updated within the time interval, the system considers the CAN bus has gone into fault mode. DO NOT SET THIS INTERVAL TO 0 (ZERO)! It is recommended to use an interval of app. 2.5 times the message update rate. For example, if the update interval is 100 msec, it is recommended to set the time interval to 250 msec. During this time interval the system should recognize 2 messages, confirming the CAN bus is functioning Turn ON / Turn OFF Select the conditions for switching ON (or OFF): = Equal to < Less than > Greater than <= Less than or equal to >= Greater than or equal to!= Not equal to Output Select which output this event controls. Select NONE if this is a conditioning event which is part of a logic switch string. It is essential that only one (1) event controls a given output. If multiple switching conditions apply, these must be joined in a single, final event, for example an AND, OR, etc event, Miscellaneous Use this section to set: Bosch PowerBox PBX 180 minimum voltage (recommended set to 6,000 mv) The battery voltage level has to drop below the low threshold for 10 seconds before outputs are switched off. The voltage level has to rise above the minimum voltage level plus 0.5 V for mini-mum 10 seconds before outputs are turned on again. Bosch PowerBox PBX 180 maximum voltage (set to 24,000 mv) Special Functions It is possible to assign outputs to switch ON or to switch OFF when specific events are selected. For example, to maximize engine cranking speed and to preserve battery power Bosch PowerBox PBX 180 can be configured to disable other outputs whilst the starter motor is activated. Create an event for activating the Bosch Motorsport PowerBox PBX / 60
20 5 Functions starter solenoid. Select this event as for example EVENT 01 in section SPECIAL OFF. Open the output map and select which outputs to switch OFF (if ON) when the starter is activated. Click on Set Output Map to open the configuration tables. Each output can be linked to 8 condition-ing events. To turn a specific output off when the input event is true tick the box for the outputs as shown. Please note, that special function maps have overall priority over any event controlled function Counters This function is not yet implemented. Status This section displays the general Bosch PowerBox PBX 180 status: Status for digital switches are shown as Open, Low or High Analogue channels displays sensor input voltage Bosch PowerBox PBX 180 on-board temperature measurement in C on signal and power boards Tri-state output voltages Real time current draws for low, high and very high outputs Status of the three analogue sensor reference voltage supply (VREF) Warning light status CAN channels displays decimal channel values. Counters are not yet implemented. Warning Light Status The warning light will flash error codes, making it easy to trace an eventual fault: 1 flash Error on CAN 1 (you can select in tool if you want to enable this option).displays value "1" in tool on status page. 2 flashes Error on CAN 2 (you can select in tool if you want to enable this option).displays value "2" in tool on status page. 3 flashes Error on CAN 3 (you can select in tool if you want to enable this option).displays value "4" in tool on status page. 20 / 60 PowerBox PBX 180 Bosch Motorsport
21 Functions 5 4 flashes Error on CAN 4 (you can select in tool if you want to enable this option). Displays value "8" in tool on status page 5 flashes Power output. Displays value "16" in tool on status page. 6 flashes Miscellaneous output. Displays value "32" in tool on status page. 7 flashes Real time clock. Displays value "64" in tool on status page. 8 flashes Faulty configuration. Displays value "128" in tool on status page. This diagnostics can also display a combination of errors Events Monitor This section displays the status of Bosch PowerBox PBX 180 events. Green resembles a TRUE event. Blue resembles a FALSE event. Output Diagnostics This section displays the Bosch PowerBox PBX 180 system diagnostic: The columns illustrate: Current Actual real time current draw, updates when the tool is connected and the current draw changes, measured in steps of 100 ma. Bosch Motorsport PowerBox PBX / 60
22 5 Functions Peak Highest recorded peak current. OCL Number of times the output current draw has exceeded the user-defined Over Current Low threshold (low hardware setting). OCH Number of times the output current draw has exceeded the fixed Over Current High setting (75 A in LP, 100 A in HP). OCS Number of times the output current draw has exceeded the software threshold, Over Current Soft, the fuse value. Thm Thermal shut down due to high junction temperatures. Stat Status of output channel: Fault Status Hex Value STATUS_OUTPUT_OFF_OK 0x STATUS_OUPTUT_ON_OK 0x STATUS_OUTPUT_SHUTDOWN_OVER_VOLTAGE 0x STATUS_OUTPUT_SHUTDOWN_UNDER_VOLTAGE 0x STATUS_OUTPUT_SHUTDOWN_OPEN_LOAD 0x STATUS_OUTPUT_SHUTDOWN_OVER_CURRENT_LOW 0x STATUS_OUTPUT_SHUTDOWN_OVER_CURRENT_HIGH 0x STATUS_OUTPUT_SHUTDOWN_OVER_THERMAL 0x STATUS_OUTPUT_SHUTDOWN_OVER_SOFT_CURRENT 0x STATUS_OUTPUT_SHUTDOWN_OVER_SOFT_CURRENT_RE- TRY Channels not supported are: Low power 29, 30, 31 and 32. All PWM channels All tri-state outputs All VREF sensor supplies Value Description 0 Channel switched off. 1 Channel switched on. 8 Channel switched off and has no load connected to it. 0x Decimal Value 22 / 60 PowerBox PBX 180 Bosch Motorsport
23 Functions 5 Error status codes are normally shown as a combination of numbers: Value Description 17 Bosch PowerBox PBX 180 is trying to switch the channel on, but the current draw has exceeded the low hardware (OCL) threshold and has gone into an error status. 33 Bosch PowerBox PBX 180 is trying to switch the channel on, but the current draw has exceeded the high hardware (OCH) threshold and has gone into an error status. 129 Bosch PowerBox PBX 180 is trying to switch the channel on, but the current draw has exceeded the software (OCS) threshold and has gone into an error status. Using the Reset event to reset any outputs in error status does not clear this diagnostic. Only channels which have failed will be reset. In general, switching a channel OFF then ON will attempt a restart, even if the channel has failed earlier. To clear diagnostic, look in the tools main menu in "Device". Clicking on "Reset Output Counters" will reset diagnostics. Bosch Motorsport PowerBox PBX / 60
24 6 Inputs Inputs Bosch PowerBox PBX 180 has 14 digital and 16 analogue inputs. These inputs can be used with sensors or switches. Furthermore, Bosch PowerBox PBX 180 has 4 individual CAN lines with a maximum of 64 CAN channels and unlimited assigning of identifiers. Bosch PowerBox PBX 180 is fitted with 2 internal temperature sensors for system monitoring. Digital Inputs 14 digital inputs are available as switch inputs, but can also be assigned as wheel speed sensor inputs, for example. The intention with the Bosch PowerBox PBX 180 is to simplify the wiring installation as much as possible. If you use the digital inputs for external toggle switches, you have to connect up to 14 signal wires to the module. But if you choose to control Bosch PowerBox PBX 180 via CAN, you can control all functions via a 2-wire data bus for each CAN bus. Input names can be up to 15 characters long. Digital inputs can be triggered by: Connecting to ground Connecting to open circuit Connecting to battery voltage Configuration of switch condition is set within the event handling. Defining whether an input is considered latching or momentary is also done within the event han-dling. Set the minimum debounce time required for the system to acknowledge a switch signal. If a digital input is used with a speed sensor, the sensor must be a Hall effect sensor. Channel status is displayed. Pin Configuration Digital Inputs: Digital Input Connector 4 Pin 1 AS SN 8 2 AS SN 7 3 AS SN 3 4 AS SN 13 5 AS SN 2 6 AS SN 6 7 AS SN 1 8 AS SN 12 9 AS SN 5 10 AS SN AS SN 4 12 AS SN AS SN AS SN / 60 PowerBox PBX 180 Bosch Motorsport
25 Inputs Analogue Inputs Bosch PowerBox PBX 180 has 16 analogue 0 to 12 V sensor inputs with a 16 bit resolution. Fur-thermore, these inputs can be grouped to create 8 differential inputs (not implemented yet). Input names can be up to 15 characters long. Analogue inputs can be assigned having different characteristics: Pull-up to VREF through a 3,16 kohm resistor (for use with NTC temperature sensors) Pull-up to VREF through a 47 kohm resistor Floating input Section Conversion gives access to a linearization table having 32 breakpoints. Any number of breakpoints can be used, a 2-point calibration of a pressure sensor only requires two. If a sensor A/D value is below the minimum breakpoint, the minimum value is applied. If a sensor A/D value is above the maximum breakpoint, the maximum value is applied. Leaving all breakpoints at 0 (zero) channel values are displayed in mv. Sensor scaling is normally entered in for example mbar, ml, ma etc. Use the column Divisor to scale mbar to bar etc. Sensor channel values are displayed in real time in both raw and scaled sensor values. Please note that the analogue inputs are disabled in the instant when power to the Bosch PowerBox PBX 180 is switched off. Pin Configuration Analogue Inputs: Analogue Input Connector 4 Pin 1 AS SN 48 2 AS SN 49 3 AS SN 53 Bosch Motorsport PowerBox PBX / 60
26 6 Inputs 4 AS SN 43 5 AS SN 54 6 AS SN 50 7 AS SN 55 8 AS SN 44 9 AS SN AS SN AS SN AS SN AS SN AS SN AS SN AS SN CAN Inputs Bosch PowerBox PBX 180 has 4 individual CAN busses. Each CAN bus can be defined as 11 or 29 bit identifier. Additionally, each of these 4 CAN bus can be individually terminated and the baud rate for each is selectable. Each of the 64 available CAN inputs can be named as required. Select on which of the four CAN bus the actual channel is found. Set the identifier in which the actual channel is included. This value must be in hex, for example 0x119. Select the unit of the channel, for example RPM, bar, deg etc, Section Set Points gives access to a linearization table having 32 breakpoints. Any number of breakpoints can be used, a 2-point calibration of a pressure sensor only requires two. If a sensor A/D value is below the minimum breakpoint, the minimum value is applied. If a sensor A/D value is above the maximum breakpoint, the maximum value is applied. Leaving all breakpoints at 0 (zero) channel values are displayed in bits (for channels sent as byte or word) or in a decimal value (if the channel is transmitting bit values). 26 / 60 PowerBox PBX 180 Bosch Motorsport
27 Inputs 6 For each individual CAN bus there is no limitation to the numbers of CAN identifiers selected. Each of the 64 available CAN inputs can use a unique identifier. Identifiers do not have to be arranged in special groups. CAN channels can contain a switch status, 8 bit data channels or 16 bit data channels. A typical switch status uses the individual 8 bits within a single byte. An 8 bit data channel reads data in the range between 0 and 255 and uses 1 byte. A 16 bit data channel reads data in the range between 0 and and uses 2 bytes. 16 bit channels can be arranged as either Big Endian (Motorola format) or Little Endian (Intel format). When configured as Big Endian the two bytes are arranged as [(MSB); (LSB)], for example byte 0 is High (MSB) and byte 1 is Low (LSB). When configured as Little Endian the two bytes are arranged as [(LSB); (MSB)]. Bit management within each of the 8 bytes is available. Each byte contains 8 bits which are numbered this way: Byte 0 = 0 to 7 bits Byte 1 = 8 to 15 bits Byte 2 = 16 to 23 bits Byte 3 = 24 to 31 bits Byte 4 = 32 to 39 bits Byte 5 = 40 to 47 bits Byte 6 = 48 to 55 bits Byte 7 = 56 to 63 bits Using bit wise operator it is possible to address for example status of 8 individual switches. The decimal values of the bits in a byte are: Bit 0 = 1 Bosch Motorsport PowerBox PBX / 60
28 6 Inputs Bit 1 = 2 Bit 2 = 4 Bit 3 = 8 Bit 4 = 16 Bit 5 = 32 Bit 6 = 64 Bit 7 = 128 Example: To read the data from bit 4 in byte 1 of a given identifier proceed this way: 1. In section Low Byte un-tick Bit Selection OR Byte Selection 2. Click on the arrow down and select the byte containing the data information, for example byte 1 3. Tick Bit Selection OR Byte Selection 4. Deselect reading of data from bits 0, 1, 2, 3, 5, 6 and 7 by selecting the option - - from the scroll down menu for each of these bits. 5. An easy way to proceed is to click once on one of the bit windows, then press END (now the se-lection - - is displayed). Using the TAB key jump to the next bit, press END, then the TAB key again etc. 6. Leave bit 4 on the value of 12. Bosch PowerBox PBX 180 will detect and report an eventual short circuit of a CAN bus. After a short circuit the CAN bus will reset. Pin Configuration for CAN Communication: Name Connector 4 Pin CAN1 H AS SN 24 CAN1 L AS SN 23 CAN2 H AS SN 16 CAN2 L AS SN 15 CAN3 H AS SN 9 CAN3 L AS SN 22 CAN4 H AS SN 14 CAN4 L AS SN / 60 PowerBox PBX 180 Bosch Motorsport
29 Outputs Outputs Bosch PowerBox PBX 180 has 48 power channels with current measurement plus 4 analogue trigger outputs. All power outputs are designed for use in harsh environments and include self-recovery features. Outputs are designed to handle loads with high inrush current as well as motors and all types of resistive and inductive loads. All outputs are protected against reversed battery polarity and too high temperatures. The power channels are divided into groups: Low power outputs (ON/OFF switches) Low power wiper outputs (ON/OFF switches) with recirculation diodes Low power outputs with pulse width modulation (PWM) (frequency controlled duty cycle) High power outputs (ON/OFF switches) High power outputs with pulse width modulation (PWM) (frequency controlled duty cycle) Very high power outputs (ON/OFF switches) The tri-state analogue outputs cannot be used as power supplies; they can only be used as trigger signals. Please note that the current draw per channel is limited by the connector not by the driver stages. We have rated the individual channel s current draw in relation to the connector manufacturer s specifications. Tri-State Outputs Tri-state outputs cannot be used as power supplies. They are designed as logic switches and are used only as trigger signals for analogue inputs on other modules, for example an ECU. They are controlled by the event handling and the output signals can have these values: 0 V 2.5 V 5.0 V Please read also the description from tri-state event in Events section. Tri-state Max current, A Connector 3 Pin 1 - AS SA Y 2 - AS SA B 3 - AS SA Z 4 - AS SA C 7.2 Low Power Outputs This section gives access to: Bosch Motorsport PowerBox PBX / 60
30 7 Outputs Naming of output Set inrush current threshold Set time interval for inrush current Set the normal fused threshold Set the number of retries once a fault is detected before switching off Set the time interval for fault resetting 26 low power outputs are available, supplying a maximum continuous current of 8 A each chan-nel. Please observe that our recommended current rating each channel is given in accordance with Deutsch s current limit for the size AWG20 contacts in the Autosport connector. Current draw can be measured on all outputs. On outputs 1 to 22 current can be measured from 200 ma to full load. Outputs 23 to 26 all have increased resolution making them a preferred selec-tion for lift pumps, for example. The driver stages can deliver significantly more current, but it is important to avoid overloading the wiring and contacts in the connector. Once an output is turned on, the current draw depends on the attached load. If this load is a resistive load, there will hardly be any inrush current. If the output drives a motor or a lamp, for example, there can be a substantial inrush for a certain amount of time. The current draw will quickly decrease and reach a steady state level. Outputs are protected by three current thresholds and three timers: OCH is the high current threshold of 75 A. OCL is the user defined continuous current threshold. This level is selectable between 7.5 A to 12.5 A. OCS is the software selected current threshold. 30 / 60 PowerBox PBX 180 Bosch Motorsport
31 Outputs 7 1. Switching an output ON, an inrush current up to and in excess of 75 A is allowed for a 20 usec time interval. 2. After these 20 usec the current level must be below OCH which is 75 A. 3. Within a time interval, selectable between 0.15 to 155 msec, from switching the output ON, the current draw must have fallen below the OCL threshold. This threshold can be set to 7.5 A, 10 A, 12.5 A. 4. In column INIT ms key in the time delay for applying the steady state fuse level defined in NORM ma. This interval must exceed the time interval selected for OCL, suggested value > 200 msec. Maximum time is limited to 10 seconds. 5. After the time interval INIT, the initial time from switching the output ON, the current draw must be below the user defined software fuse level, OCS. If the current draw exceeds this threshold, the output will be switched off. 6. In column NORM ma key in the steady state fuse level required. This value must be lower than the maximum fuse level, OCL. Maximum current threshold is 13,000 ma. 7. If the current draw on an output exceeds the NORM fuse setting, the output will switch off. 8. In Retry set the maximum number of automatic re-activation of an output channel after is has been shut down caused by a short circuit or an overload. It is strongly recommended not to ex-aggerate the number of retries select a number < In Retry ms set the time interval between retries in milliseconds. 10. The status window will show the real time current draw of the output in ma. 11. Use the Manual option to test the output connection. When Manual is active, Bosch PowerBox PBX 180 s event handling has been deactivated and all channels are OFF by default. 12. Click the ON button for each individual channel to switch the output ON. 13. Click the ON button again to switch the output OFF. 14. Clicking on Trigger will open the main event controlling this output. A warning may appear if several events are used to control it. LP OUT Max current, A Connector 3 Pin 1 8 AS SA e 2 8 AS SA N 3 8 AS SA f Bosch Motorsport PowerBox PBX / 60
32 7 Outputs 4 8 AS SA P 5 8 AS SA q 6 8 AS SA R 7 8 AS SA g 8 8 AS SA S 9 8 AS SA h 10 8 AS SA T 11 8 AS SA i 12 8 AS SA U 13 8 AS SA d 14 8 AS SA K 15 8 AS SA n 16 8 AS SA L 17 8 AS SA p 18 8 AS SA M 19 8 AS SA c 20 8 AS SA J 21 8 AS SA G 22 8 AS SA H 23 8 (high resolution current measurement) AS SA F 24 8 (high resolution current measurement) AS SA b 25 8 (high resolution current measurement) AS SA D 26 8 (high resolution current measurement) AS SA E 7.3 Low Power PWM Outputs This section gives access to: Naming of output Set inrush current threshold Set time interval for inrush current Set the normal fused threshold Set the number of retries once a fault is detected before switching off Set the time interval for fault resetting Select the type of PWM applied Define duty cycle or frequency map 4 low power outputs are available with PWM capability applying frequencies from 30 Hz up to 25 khz and of supplying a maximum, recommended continuous current of 8 A each channel. Please observe that our recommended maximum current rating for each of these four channels is given in accordance with 32 / 60 PowerBox PBX 180 Bosch Motorsport
33 Outputs 7 Deutsch s current limit for the size AWG20 contacts in the Autosport connector. The driver stages can deliver significantly more current, but it is important to avoid overloading the wiring and contacts in the connector. Warning Do not connect PWM output channels in parallel. Current draw can be measured on all outputs and displays the maximum current draw, neglecting the OFF periods. Outputs are protected by three current thresholds and three timers: OCH is the high current threshold of 75 A. OCL is the user defined continuous current threshold. This level is selectable between 7.5 A to 12.5 A. OCS is the software selected current threshold. Switching an output ON, an inrush current up to and in excess of 75 A is allowed for a 20 usec time interval. After these 20 usec the current level must be below OCH which is 75 A. Within a time interval, selectable between 0.15 to 155 msec, from switching the output ON, the current draw must have fallen below the OCL threshold. This threshold can be set to 7.5 A, 10 A, 12.5 A. In column INIT ms key in the time delay for applying the steady state fuse level defined in NORM ma. This interval must exceed the time interval selected for OCL, suggested value > 200 msec. Maximum time is limited to 10 seconds. After the time interval INIT, the initial time from switching the output ON, the current draw must be below the user defined software fuse level, OCS. If the current draw exceeds this threshold, the output will be switched off. Bosch Motorsport PowerBox PBX / 60
34 7 Outputs In column NORM ma key in the steady state fuse level required. This value must be lower than the maximum fuse level, OCL. Maximum current threshold is 13,000 ma. If the current draw on an output exceeds the NORM fuse setting, the output will switch off. In Retry set the maximum number of automatic re-activation of an output channel after is has been shut down caused by a short circuit or an overload. It is strongly recommended not to ex-aggerate the number of retries select a number < 10. In Retry ms set the time interval between retries in milliseconds. PWM Type is used to define the functionality of the PWM feature: PWM Type None PWM Feature Output disabled Dig out No PWM used, output is off or on 100% Duty intrp Duty down Duty up Duty near Freq intpr Freq down Freq up Freq near Interpolation between duty cycle breakpoints Duty cycle from nearest lower breakpoint applied Duty cycle from nearest higher breakpoint applied Duty cycle from nearest lower or higher breakpoint applied Interpolation between frequency breakpoints Frequency from nearest lower breakpoint applied Frequency from nearest higher breakpoint applied Frequency from nearest lower or higher breakpoint applied The frequency option is only available on LP PWM3 and LP PWM Duty Cycle Maps Duty cycle maps are designed with variables on both X and Y axis. Use the drop down menus to select the channels used for the X and Y axis of the table. 34 / 60 PowerBox PBX 180 Bosch Motorsport
35 Outputs 7 It is not necessary to use the full table and all breakpoints in the maps nor to use both axis's. Using a two-axis calibration, start filling the map out from upper left hand corner. Using a single axis calibration, select the X or Y-axis as the input reference, using only the first row or column of the other axis. The map can be imported and exported to Excel. An easy way to create a duty cycle map is to follow this procedure: 1. Open the duty cycle map. 2. Click Copy. 3. Paste into Excel. 4. Modify table. 5. Mark the table and copy. 6. Return to the tool and click past. 7. Set frequency in Hz; minimum applied value is 30 Hz, maximum value is 15 khz. Please note that LP PWM1 and LP PWM2 must use the same frequency! Frequency Maps Frequency maps are single axis maps; the duty cycle percentage must be kept constant. Please note that frequency mapping is only available on LP PWM3 and LP PWM4. Use the drop down menus to select the channel used for the single axis of the table. The map can be imported and exported to Excel. An easy way to create a frequency map is to follow this procedure: 1. Open the frequency map. 2. Click Copy. 3. Paste into Excel. 4. Modify table. 5. Mark the table and copy. 6. Return to the tool and click past. 7. Set the applied duty cycle percentage; values can be between 5 and 99%. The Status window shows the real time current draw of the output in ma. 8. Use the Manual option to test the output connection. When Manual is active (see section 4.3), Bosch PowerBox PBX 180 s event handling has been deactivated and all channels are OFF by default. 9. Click the ON button for each individual channel to switch the output ON. Bosch Motorsport PowerBox PBX / 60
36 7 Outputs 10. Click the ON button again to switch the output OFF. 11. Clicking on Trigger will open the main event controlling this output. A warning may appear if several events are used to control it. The status window will show the real time current draw of the output in ma. 12. Use the Manual option to test the output connection. When Manual is active (see section 4.3), Bosch PowerBox PBX 180 s event handling has been deactivated and all channels are OFF by default. 13. Click the ON button for each individual channel to switch the output ON. 14. Click the ON button again to switch the output OFF. 15. Clicking on Trigger will open the main event controlling this output. A warning may appear if several events are used to control it. LP PWM OUT Max current, A Connector 3 Pin 1 8 AS SA k 2 8 AS SA V 3 8 AS SA j 4 8 AS SA W 7.4 High Power Outputs This section gives access to: Naming of output Set inrush current threshold Set time interval for inrush current Set the normal fused threshold Set the number of retries once a fault is detected before switching off Set the time interval for fault resetting 12 high power outputs are available, supplying a maximum continuous current of 20 A each channel. Please observe that our recommended current rating each channel is given in accordance with Deutsch s current limit for the size AWG16 contacts in the Autosport connector. Current draw can be measured on all outputs. 36 / 60 PowerBox PBX 180 Bosch Motorsport
37 Outputs 7 The driver stages can deliver significantly more current, but it is important to avoid overloading the wiring and contacts in the connector. Once an output is turned on, the current draw depends on the attached load. If this load is a resistive load, there will hardly be any inrush current. If the output drives a motor or a lamp, for example, there can be a substantial inrush for a certain amount of time. The current draw will quickly decrease and reach a steady state level. Outputs are protected by three current thresholds and three timers: OCH is the high current threshold of 100 A. OCL is the user defined continuous current threshold. This level is selectable as 15 A, 20 A or 25 A. OCS is the software selected current threshold. 1. Switching an output ON, an inrush current up to and in excess of 100 A is allowed for a 20 usec time interval. 2. After these 20 usec the current level must be below OCH which is 100 A. 3. Within a time interval, selectable between 0.15 to 155 msec, from switching the output ON, the current draw must have fallen below the OCL threshold. This threshold can be set to 15 A, 20 A, 25 A. 4. In column INIT ms key in the time delay for applying the steady state fuse level defined in NORM ma. This interval must exceed the time interval selected for OCL, suggested value > 200 msec. 5. Maximum time is limited to 10 seconds. 6. After the time interval INIT, the initial time from switching the output ON, the current draw must be below the user defined software fuse level, OCS. If the current draw exceeds this threshold, the output will be switched off. 7. In column NORM ma key in the steady state fuse level required. This value must be lower than the maximum fuse level, OCL. Maximum current threshold is 26,000 ma. 8. If the current draw on an output exceeds the NORM fuse setting, the output will switch off. 9. In Retry set the maximum number of automatic re-activation of an output channel after is has been shut down caused by a short circuit or an overload. It is strongly recommended not to ex-aggerate the number of retries select a number < In Retry ms set the time interval between retries in milliseconds. Bosch Motorsport PowerBox PBX / 60
38 7 Outputs 11. The status window will show the real time current draw of the output in ma. 12. Use the Manual option to test the output connection. When Manual is active (see section 4.3), Bosch PowerBox PBX 180 s event handling has been deactivated and all channels are OFF by default. 13. Click the ON button for each individual channel to switch the output ON. 14. Click the ON button again to switch the output OFF. 15. Clicking on Trigger will open the main event controlling this output. A warning may appear if several events are used to control it. Channel Max current, A Connector 4 Pin 3 20 AS SN M 4 20 AS SN K 5 20 AS SN F 6 20 AS SN N 7 20 AS SN R 8 20 AS SN S 9 20 AS SN D AS SN A AS SN L AS SN J 7.5 Very High Power This section gives access to: Naming of output Set inrush current threshold Set time interval for inrush current Set the normal fused threshold Set the number of retries once a fault is detected before switching off Set the time interval for fault resetting 2 very high power outputs are available, supplying a maximum continuous current of 20 A each channel. Please observe that our recommended current rating each channel is given in accordance with Deutsch s current limit for the size AWG16 contacts in the Autosport connector. Current draw can be measured on all outputs. 38 / 60 PowerBox PBX 180 Bosch Motorsport
39 Outputs 7 The driver stages can deliver significantly more current, but it is important to avoid overloading the wiring and contacts in the connector. Once an output is turned on, the current draw depends on the attached load. If this load is a resistive load, there will hardly be any inrush current. If the output drives a motor or a lamp, for example, there can be a substantial inrush for a certain amount of time. The current draw will quickly decrease and reach a steady state level. Outputs are protected by three current thresholds and three timers: OCH is the high current threshold of 150 A. OCL is the user defined continuous current threshold. This level is selectable as 2 x 30 A or 2 x 40 A. OCS is the software selected current threshold. 1. Switching an output ON, an inrush current up to and in excess of 150 A is allowed for a 20 usec time interval. 2. After these 20 usec the current level must be below OCH which is 150 A. 3. Within a time interval, selectable between 0.15 to 155 msec, from switching the output ON, the current draw must have fallen below the OCL threshold. This threshold can be set to 30 A, 40 A. 4. In column INIT ms key in the time delay for applying the steady state fuse level defined in NORM ma. This interval must exceed the time interval selected for OCL, suggested value > 200 msec. 5. Maximum time is limited to 10 seconds. 6. After the time interval INIT, the initial time from switching the output ON, the current draw must be below the user defined software fuse level, OCS. If the current draw exceeds this threshold, the output will be switched off. 7. In column NORM ma key in the steady state fuse level required. This value must be lower than the maximum fuse level, OCL. Maximum current threshold is 26,000 ma. 8. If the current draw on an output exceeds the NORM fuse setting, the output will switch off. 9. In Retry set the maximum number of automatic re-activation of an output channel after is has been shut down caused by a short circuit or an overload. It is strongly recommended not to ex-aggerate the number of retries select a number < In Retry ms set the time interval between retries in milliseconds. Bosch Motorsport PowerBox PBX / 60
40 7 Outputs 11. The status window will show the real time current draw of the output in ma. 12. Use the Manual option to test the output connection. When Manual is active (see section 4.3), Bosch PowerBox PBX 180 s event handling has been deactivated and all channels are OFF by default. 13. Click the ON button for each individual channel to switch the output ON. 14. Click the ON button again to switch the output OFF. 15. Clicking on Trigger will open the main event controlling this output. A warning may appear if several events are used to control it. Channel Max current, A Connector 4 Pin VHP1 20 AS SN B VHP2 20 AS SN C 7.6 High Power PWM Outputs This section gives access to: Naming of output Set inrush current threshold Set time interval for inrush current Set the normal fused threshold Set the number of retries once a fault is detected before switching off Set the time interval for fault resetting Set frequency for pulse width modulation (PWM) NOT YET IMPLEMENTED. Define duty cycle map 2 high power outputs are available with PWM capability applying frequencies up to 25 khz and of supplying a maximum continuous current of 20 A each channel. Please observe that our rec-ommended current rating each channel is given in accordance with Deutsch s current limit for the size AWG16 contacts in the Autosport connector. The driver stages can deliver significantly more current, but it is important to avoid overloading the wiring and contacts in the connector. Warning Do not connect PWM output channels in parallel. Current draw can be measured on all outputs. Outputs are protected by three current thresholds and three timers: OCH is the high current threshold of 100 A. OCL is the user defined continuous current threshold. This level is selectable as 7.5 A, 10 A, 12.5 A, 15 A, 20 A or 25 A. 40 / 60 PowerBox PBX 180 Bosch Motorsport
41 Outputs 7 OCS is the software selected current threshold. 1. Switching an output ON, an inrush current up to and in excess of 100 A is allowed for a 20 usec time interval. 2. After these 20 usec the current level must be below OCH which is 100 A. 3. Within a time interval, selectable between 0.15 to 155 msec, from switching the output ON, the current draw must have fallen below the OCL threshold. This threshold can be set to 10 A, 12.5 A, 20 A or 25 A. 4. In column INIT ms key in the time delay for applying the steady state fuse level defined in NORM ma. This interval must exceed the time interval selected for OCL, suggested value > 200 msec. 5. Maximum time is limited to 10 seconds. 6. After the time interval INIT, the initial time from switching the output ON, the current draw must be below the user defined software fuse level, OCS. If the current draw exceeds this threshold, the output will be switched off. 7. In column NORM ma key in the steady state fuse level required. This value must be lower than the maximum fuse level, OCL. Maximum current threshold is 26,000 ma. 8. If the current draw on an output exceeds the NORM fuse setting, the output will switch off. 9. In Retry set the maximum number of automatic re-activation of an output channel after is has been shut down caused by a short circuit or an overload. It is strongly recommended not to exaggerate the number of retries select a number < In Retry ms set the time interval between retries in milliseconds. PWM Type is used to define the functionality of the PWM feature: PWM Type None PWM feature Output disabled Dig out No PWM used, output is off or on 100% Duty intrp Duty down Duty up Duty near DO NOT USE THIS OPTION ON Bosch PowerBox PBX 180 SERIAL <076 Interpolation between duty cycle breakpoints Duty cycle from nearest lower breakpoint applied Duty cycle from nearest higher breakpoint applied Duty cycle from nearest lower or higher breakpoint applied Bosch Motorsport PowerBox PBX / 60
42 7 Outputs Duty Cycle Maps Duty cycle maps are designed with variables on both X and Y axis. Use the drop down menus to select the channels used for the X and Y axis of the table. It is not necessary to use the full table and all breakpoints in the maps nor to use both axis's. Using a two-axis calibration, start filling the map out from upper left hand corner. Using a single axis calibration, select the X or Y-axis as the input reference, using only the first row or column of the other axis. The map can be imported and exported to Excel. An easy way to create a duty cycle map is to follow this procedure: 1. Open the duty cycle map. 2. Click Copy. 3. Paste into Excel. 4. Modify table. 5. Mark the table and copy. 6. Return to the tool and click past. 7. Set frequency in Hz; minimum applied value is 30 Hz, maximum value is 15 khz. 8. HP PWM1 and HP PWM2 must use the same frequency. The Status window shows the real time current draw of the output in ma. 9. Use the Manual option to test the output connection. When Manual is active (see section 4.3), Bosch PowerBox PBX 180 s event handling has been deactivated and all channels are OFF by default. 10. Click the ON button for each individual channel to switch the output ON. 11. Click the ON button again to switch the output OFF. 12. Clicking on Trigger will open the main event controlling this output. A warning may appear if several events are used to control it. The status window will show the real time current draw of the output in ma. 42 / 60 PowerBox PBX 180 Bosch Motorsport
43 Outputs Use the Manual option to test the output connection. When Manual is active (see section 4.3), Bosch PowerBox PBX 180 s event handling has been deactivated and all channels are OFF by default. 14. Click the ON button for each individual channel to switch the output ON. 15. Click the ON button again to switch the output OFF. 16. Clicking on Trigger will open the main event controlling this output. A warning may appear if several events are used to control it. HP PWM OUT Max current, A Connector 3 Pin 1 20 AS SN G 2 20 AS SN H 7.7 Sensor Supplies Bosch PowerBox PBX 180 has 3 stabilized 5.0 V sensor supplies (VREF) for use with the analogue sensor inputs. Maximum current draw from each output is 1.0 A. Channel Max current, A Connector 4 Pin VREF1 1.0 AS SN 32 VREF2 1.0 AS SN 40 VREF3 1.0 AS SN Wiper Outputs 2 dedicated outputs for wiper motors are available. These two channels have additional protection diodes and can handle the load dump created when the wiper motor stops. Wiper motors can also be controlled by the LIN bus (in preparation). The 2 power outputs can supply a maximum continuous current of 8 A each channel. Please observe that our recommended current rating each channel is given in accordance with Deutsch s current limit for the size AWG20 contacts in the Autosport connector. The driver stages can deliver significantly more current, but it is important to avoid overloading the wiring and contacts in the connector. Once an output is turned on, the current draw depends on the attached load. Bosch Motorsport PowerBox PBX / 60
44 7 Outputs If this load is a resistive load, there will hardly be any inrush current. If the output drives a motor or a lamp, for example, there can be a substantial inrush for a certain amount of time. The current draw will quickly decrease and reach a steady state level. Outputs are protected by three current thresholds and three timers: OCH is the high current threshold of 75 A. OCL is the user defined continuous current threshold. This level is selectable between 7.5 A to 12.5 A. OCS is the software selected current threshold. 1. Switching an output ON, an inrush current up to and in excess of 75 A is allowed for a 20 usec time interval. After these 20 usec the current level must be below OCH which is 75 A. 2. Within a time interval, selectable between 0.15 to 155 msec, from switching the output ON, the current draw must have fallen below the OCL threshold. This threshold can be set to 7.5 A, 10 A, 12.5 A. 3. In column INIT ms key in the time delay for applying the steady state fuse level defined in NORM ma. This interval must exceed the time interval selected for OCL, suggested value > 200 msec. 4. Maximum time is limited to 10 seconds. 5. After the time interval INIT, the initial time from switching the output ON, the current draw must be below the user defined software fuse level, OCS. If the current draw exceeds this threshold, the output will be switched off. 6. In column NORM ma key in the steady state fuse level required. This value must be lower than the maximum fuse level, OCL. Maximum current threshold is 13,000 ma. 7. If the current draw on an output exceeds the NORM fuse setting, the output will switch off. 8. In Retry set the maximum number of automatic re-activation of an output channel after is has been shut down caused by a short circuit or an overload. It is strongly recommended not to exaggerate the number of retries select a number < In Retry ms set the time interval between retries in milliseconds. 10. The status window will show the real time current draw of the output in ma. 11. Use the Manual option to test the output connection. When Manual is active (see section 4.3), Bosch PowerBox PBX 180 s event handling has been deactivated and all channels are OFF by default. 44 / 60 PowerBox PBX 180 Bosch Motorsport
45 Outputs Click the ON button for each individual channel to switch the output ON. 13. Click the ON button again to switch the output OFF. 14. Clicking on Trigger will open the main event controlling this output. A warning may appear if several events are used to control it. WPM OUT Max current, A Connector 3 Pin WP1 8 AS SA X WP2 80 AS SA A Warning Lamp Bosch PowerBox PBX 180 is equipped with a warning light for error detection. The driver output is found in connector 4, pin 42. If a fault is detected, the channel switches 5.0 V ON, maximum current draw is 1.0 A. Fault Reset You can reset all output channels in error status by briefly connecting the selected reset channel to ground. A reset channel can be assigned as an event. In this case any input - analogue, digital or CAN and the dedicated warning light output can be assigned. Use the event settings to define the switching conditions. Resetting Bosch PowerBox PBX 180 only affects channels in error state. The reset function will not reboot the PCM in general and has no influence on outputs in normal operation state. It will only reboot channels which have switched off after their pre-defined automatic resetting conditions. The reset will reboot channels which were shut down due to overload of OCH, OCL and OCS. Channel Max current, A Connector 4 Pin WL1 5.0 V at 1.0 A AS SN 42 Bosch Motorsport PowerBox PBX / 60
46 8 CAN Bus 8 CAN Bus Data Bus Bosch PowerBox PBX 180 has 4 separate CAN busses, two are implemented in the current software release. Select the CAN bus number to be edited. If a CAN bus fails, for example after a short circuit, Bosch PowerBox PBX 180 will automatically reset the CAN stream. CAN Bus Name Each CAN bus can be labeled individually to ease identification. Maximum 15 characters can be used. This can be used for each individual CAN bus. CAN Bus Speed Baud rate for each CAN bus can be selected as: 10 kbps 20 kbps 50 kbps 125 kbps 250 kbps 500 kbps 1 Mbps This must be set for each individual CAN bus. 46 / 60 PowerBox PBX 180 Bosch Motorsport
47 CAN Bus Terminated To function correctly, a CAN bus requires a termination resistor between the two CAN wires. This is done by fitting two 120 Ohm termination resistors between CAN H and CAN L, one each end of the CAN string. All additional modules having CAN communication which will be connected to the CAN bus must have their termination resistors disabled. It is essential for the stability of the CAN bus that two and only two resistors are fitted. It is possible to enable internal termination resistors in Bosch PowerBox PBX 180, terminating one end of the CAN string. Each CAN bus can be individually terminated. By ticking the box, a 120 Ohm resistor within Bosch PowerBox PBX 180 is connected between CAN H and CAN L on the selected CAN bus. Please note that a CAN connection should not exceed 16 meters (for 1 Mbits/s baud rate) and that a CAN bus MUST be terminated at each end by a 120 Ohm resistor. CAN wires must be laid out as twisted pairs. This must be respected for each individual CAN bus. Report Error Tick the box to enable reporting of errors on each individual CAN bus. Only tick this box if the CAN bus is actually in use constantly. If one CAN bus is used for PC com-munication only then do NOT tick this option. CAN Bus Identity Set the base send and receive identifiers for each CAN bus. This must be set for each individual CAN bus. CAN Monitor A CAN bus analyzing tool is included in the PC tool. It is possible to monitor each of the 4 CAN bus. The analyzer can display all traffic on the selected bus, but it is also possible to filter the messages so that only CAN identifiers defined within Bosch PowerBox PBX 180 will be shown. CAN Export Bosch PowerBox PBX 180 can export up to 64 individual messages on any of the four CAN busses. Bosch Motorsport PowerBox PBX / 60
48 8 CAN Bus Name Use this section to give each of the 4 CAN bus a unique name. CAN Bus Select the CAN bus on which you are going to define the export. Destination Set the CAN identifier as a hex value for the export. Send every (ms) Set the identifier transmission interval in msec. Bytes For each bit, byte or word it is possible to export these values: 48 / 60 PowerBox PBX 180 Bosch Motorsport
49 CAN Bus 8 Constant Value Use this section to define a constant value of a selected byte. This is used to define a row count. Digital Input One byte can export status of 4 digital inputs. Select which digital input status to be exported in bits 0, 2, 4 and 6. Status is displayed as: 0 = off 1 = switched low 2 = switched open 3 = switched high Analogue Input It is possible to export values of each of Bosch PowerBox PBX 180 s 16 analogue inputs plus any of the 64 available CAN channels. This way it is also possible to route data from one CAN bus onto another CAN bus. Analogue channels can occupy one or two bytes. This means that up to 8 analogue channels can be exported in each byte. To export channels occupying two bytes it is possible to define which of the two bytes will be MSB and which will be LSB (Motorola or Intel format). Please note that the temperature channels listed in this section are NOT in use. Output On / Off Each individual bit in the selected byte can be used to display the status of each individual output: 0 = off 1 = on Bosch Motorsport PowerBox PBX / 60
50 8 CAN Bus Output Current Low Byte Current draw from each of the 48 power outputs can be measured. Using 1 byte for each output this section defines an export of current draw from any channel, measured in ma and up to 255 ma. Output Current Mid Byte Current draw from each of the 48 power outputs can be measured. This section uses 2 bytes, combining mid and low byte, to export current draw for any channel, measured in ma with a range up to 65,535 ma. Output Tri-State Voltage Status of each tri-state output can be exported using 2 bits in each byte. Status is displayed as: 0 = 0 V 1 = 2.5 V 2 = 5 V Output Fault status Select one of the 56 outputs to transmit its fault status in the selected identifier address and byte. The fault status is transmitted as a combination of: Fault Status Hex value STATUS_OUTPUT_OFF_OK 0x STATUS_OUTPUT_ON_OK 0x STATUS_OUTPUT_SHUTDOWN_OVER_VOLTAGE 0x STATUS_OUTPUT_SHUTDOWN_UNDER_VOLTAGE 0x STATUS_OUTPUT_SHUTDOWN_OPEN_LOAD 0x STATUS_OUTPUT_SHUTDOWN_OVER_CURRENT_LOW_OCL 0x STATUS_OUTPUT_SHUTDOWN_OVER_CURRENT_HIGH_OCS 0x STATUS_OUTPUT_SHUTDOWN_OVER_THERMAL 0x STATUS_OUTPUT_SHUTDOWN_OVER_SOFT_CURRENT_OCS 0x STATUS_OUTPUT_SHUTDOWN_OVER_SOFT_CURRENT_RE- TRY Channels not supported are: Low power 29, 30, 31 and 32. All PWM channels All tri-state outputs All VREF sensor supplies Value Description 0 Channel switched off 1 Channel switched on 0x Decimal value 50 / 60 PowerBox PBX 180 Bosch Motorsport
51 CAN Bus 8 8 Channel switched off and has no load connected to it. Error status codes are normally shown as a combination of numbers: Value Description 17 Bosch PowerBox PBX 180 is trying to switch the channel on, but the current draw has exceeded the low hardware (OCL) threshold and has gone into an error status. 33 Bosch PowerBox PBX 180 is trying to switch the channel on, but the current draw has exceeded the high hardware (OCH) threshold and has gone into an error status. 129 Bosch PowerBox PBX 180 is trying to switch the channel on, but the current draw has exceeded the software (OCS) threshold and has gone into an error status. Using the Reset event to reset any outputs in error status does not clear this diagnostic. Only channels which have failed will be reset. In general, switching a channel OFF then ON will attempt a restart even if the channel has failed earlier. To clear diagnostic, look in the tools main menu in "Device". Clicking on "Reset Output Counters" will reset diagnostics. Vehicle Battery Voltage Define 2 bytes in the identifier to transmit the vehicle battery power. Status is expressed in mv, for example 13,250 mv. Events The export of event status is divided into two sections, one for the first 256 events and one for the following 256 events. Each byte in the identifier can display the status of 8 events: 0 = False 1 = True Output Current Top Byte Current draw from each of the 48 power outputs can be measured. This section uses 3 bytes, combining top, mid and low byte, to export current draw for any channel, measured in ma with a range in excess of 200,000 ma. Output Current LSB, MSB byte (ma/2) Current draw from each of the 48 power outputs can be measured. This section uses 2 bytes, combining MSB and LSB, to export current draw for any channel, scaled at 2 ma/bit with a range up to 130,000 ma. Output current LSB, MSB byte (ma/4) Current draw from each of the 48 power outputs can be measured. Bosch Motorsport PowerBox PBX / 60
52 8 CAN Bus This section uses 2 bytes, combining MSB and LSB, to export current draw for any channel, scaled at 4 ma/bit with a range up to 260,000 ma. Output current single byte (A) Current draw from each of the 48 power outputs can be measured. This section exports current draw for any channel, scaled at 1 A/bit with a range up to 255 A. Temperature C Temperatures are measured at the hottest points on the two Bosch PowerBox PBX 180 internal boards, signal and power. These values can be exported in one signed byte each. Scaling is 1 deg C/bit with a range between -127 deg C to +128 deg C. Please note that these channels are only updated with a time interval of 1.5 sec. Vehicle Current (A) This section exports the accumulated current draw by the vehicle. The channel is a single byte scaled at 1A/bit, range is 255 A. 52 / 60 PowerBox PBX 180 Bosch Motorsport
53 Pin Configuration 9 9 Pin Configuration Connector 1 - Battery Power Supply Mating connector: Deutsch ASHD SN C35 Connector 2 - High Power Outputs Mating connector: Deutsch AS PN or Souriau 8STA62016PN Pin Used for Max Recommend / MAX Peak (A) *) A Channel 10 High Power 20 / 100 B Channel 2 Very High Power 20 / 150 C Channel 1 Very High Power 20 / 150 D Channel 9 High Power 20 / 100 E Channel 1 High Power 20 / 100 F Channel 5 High Power 20 / 100 G Channel 1 High Power PWM 20 / 80 (0 to 95 % DC) **) H Channel 2 High Power PWM 20 / 80 (0 to 95 % DC) **) J Channel 12 High Power 20 / 100 K Channel 4 High Power 20 / 100 L Channel 11 High Power 20 / 100 M Channel 3 High Power 20 / 100 N Channel 6 High Power 20 / 100 P Channel 2 High Power 20 / 100 R Channel 7 High Power 20 / 100 S Channel 8 High Power 20 / 100 *) Please note that the current draw per channel is limited by the connector - not by the driver stages. **) Warning Do not connect PWM output channels in parallel. Bosch Motorsport PowerBox PBX / 60
54 9 Pin Configuration 9.3 Connector 3 - Low Power Outputs Mating connector: Deutsch AS PA or 8STA62039PA Pin Used for Max Recommend / MAX Peak (A) *) A 1 Channel Wiper 2 8 / 75 B 2 Tri-State Output 2 Trigger 0 / 2.5 / 5 V ***) C 3 Tri-State Output 4 Trigger 0 / 2.5 / 5 V ***) D 4 Channel 25 8 / 75 E 5 Channel 26 8 / 75 F 6 Channel 23 8 / 75 G 7 Channel 21 8 / 75 H 8 Channel 22 8 / 75 J 9 Channel 20 8 / 75 K 10 Channel 14 8 / 75 L 11 Channel 16 8 / 75 M 12 Channel 18 8 / 75 N 13 Channel 2 8 / 75 P 14 Channel 4 8 / 75 R 15 Channel 6 8 / 75 S 16 Channel 8 8 / 75 T 17 Channel 10 8 / 75 U 18 Channel 12 8 / 75 V 19 Channel 2 PWM 8 / 30 (0 to 100 % DC) **) W 20 Channel 4 PWM 8 / 30 (0 to 100 % DC) **) X 21 Channel Wiper 1 8 / 75 Y 22 Tri-State Output 1 Trigger 0 / 2.5 / 5 V ***) Z 23 Tri-State Output 3 Trigger 0 / 2.5 / 5 V ***) a 24 Reserved -- b 25 Channel 24 8 / 75 c 26 Channel 19 8 / 75 d 27 Channel 13 8 / 75 e 28 Channel 1 8 / 75 f 29 Channel 3 8 / 75 g 30 Channel 7 8 / 75 h 31 Channel 9 8 / 75 i 32 Channel 11 8 / 75 j 33 Channel 3 PWM 8 / 30 (0 to 100% DC) **) k 34 Channel 1 PWM 8 / 30 (0 to 100% DC) **) 54 / 60 PowerBox PBX 180 Bosch Motorsport
55 Pin Configuration 9 m 35 Power Ground n 36 Channel 15 8 / 75 p 37 Channel 17 8 / 75 q 38 Channel 5 8 / 75 r 39 Power Ground *) Please note that the current draw per channel is limited by the connector - not by the driver stages. **) Warning Do not connect PWM output channels in parallel. ***) Tri-state outputs are trigger signals for ECUs only. DO NOT CONNECT TO LOAD! 9.4 Connector 4 - Signal and Inputs Mating connector: Deutsch AS PN or Souriau 8STA61635PN Pin Used for Comments 1 Digital Input 7 Trig High / Low / Open 2 Digital Input 5 Trig High / Low / Open 3 Digital Input 3 Trig High / Low / Open 4 Digital Input 11 Trig High / Low / Open 5 Digital Input 9 Trig High / Low / Open 6 Digital Input 6 Trig High / Low / Open 7 Digital Input 2 Trig High / Low / Open 8 Digital Input 1 Trig High / Low / Open 9 CAN 3H 10 Digital Input 13 Trig High / Low / Open 11 Digital Input 12 Trig High / Low / Open 12 Digital Input 8 Trig High / Low / Open 13 Digital Input 4 Trig High / Low / Open 14 CAN 4H 15 CAN 2L 16 CAN 2H 17 RS232 TX 18 RS232 RX 19 Digital Input 14 Trig High / Low / Open 20 Digital Input 10 Trig High / Low / Open 21 CAN 4L 22 CAN 3L Bosch Motorsport PowerBox PBX / 60
56 9 Pin Configuration 23 CAN 1L 24 CAN 1H 25 LIN bus LIN_MST Connect to 26 to set as MASTER 26 LIN bus LIN_BUS 27 Ethernet TX- 28 Ethernet TX+ 29 Ethernet RX+ 30 Ethernet RX- 31 Analogue Input 16; 12 bit Pull-up 0 / 3.16k / 47k 32 Sensor supply VREF1 5.0 V at 1.0 A 33 Analogue ground 34 Analogue ground 35 Analogue ground 36 Analogue ground 37 Analogue Input 12; 12 bit Pull-up 0 / 3.16k / 47k 38 Analogue Input 14; 12 bit Pull-up 0 / 3.16k / 47k 39 Analogue Input 15; 12 bit Pull-up 0 / 3.16k / 47k 40 Sensor Supply VREF2 5.0 V at 1.0 A 41 Analogue ground 42 Warning Light + Reset 5.0 V at 1.0 A 43 Analogue Input 4; 12 bit Pull-up 0 / 3.16k / 47k 44 Analogue Input 8; 12 bit Pull-up 0 / 3.16k / 47k 45 Analogue Input 10; 12 bit Pull-up 0 / 3.16k / 47k 46 Analogue Input 13; 12 bit Pull-up 0 / 3.16k / 47k 47 Sensor Supply VREF V at 500 ma 48 Analogue Input 1; 12 bit Pull-up 0 / 3.16k / 47k Pin Used for Comments 49 Analogue Input 2; 12 bit Pull-up 0 / 3.16k / 47k 50 Analogue Input 6; 12 bit Pull-up 0 / 3.16k / 47k 51 Analogue Input 9; 12 bit Pull-up 0 / 3.16k / 47k 52 Analogue Input 11; 12 bit Pull-up 0 / 3.16k / 47k 53 Analogue Input 3; 12 bit Pull-up 0 / 3.16k / 47k 54 Analogue Input 5; 12 bit Pull-up 0 / 3.16k / 47k 55 Analogue Input 7; 12 bit Pull-up 0 / 3.16k / 47k 56 / 60 PowerBox PBX 180 Bosch Motorsport
57 Specifications Specifications 10.1 Inputs Number of digital input 14 Number of analogue inputs Number of CAN input channels (0 to 12 V; 16 bit resolution), can be regrouped as 8 differential inputs Outputs All driver stages are thermally and reverse polarity protected. Very High Power Channels Number of individual outputs 2 Maximum continuously current draw per output Maximum peak current each output 26 A 150 A inrush High Power Channels Number of individual outputs 12 Maximum continuously current draw per output Maximum peak current each output 26 A 100 A inrush High Power PWM Channels Number of individual outputs 2 Maximum continuously current draw per output Maximum peak current each output Maximum applied frequency 26 A 100 A inrush 25 khz Low Power Channels Number of individual outputs 26 Maximum continuously current draw per output Maximum peak current each output 13 A 75 A inrush Bosch Motorsport PowerBox PBX / 60
58 10 Specifications Low Power PWM Channels Number of individual outputs 4 Maximum continuously current draw per output*) Maximum peak current each output Maximum applied frequency 13 A 75 A inrush 25 khz Wiper Channels Number of individual outputs Maximum continuously current draw per output Maximum peak current each output Notes 2 (with protection diodes) 13 A 75 A inrush Can be used as normal outputs Sensor Supplies Number of 5 V reference sensor supplies 3; each 1.0 A at 5 V Tristate Supplies Number of tri-state logic outputs 4 Voltage level of tri-state analogue outputs 0 V / 2.5 V / 5.0 V at 50 ma 10.3 Maximum Current Rating Maximum recommended output current 180 A continuously; > 300 A peak current 10.4 Temperatures Maximum operating temperature 85 C 10.5 Communication PC Interface CAN bus 4 CAN protocol 2.0B CAN baud rate (each CAN bus) CAN 1 to 4 (only CAN in current release) 10 kbps to 1 Mbps 58 / 60 PowerBox PBX 180 Bosch Motorsport
59 Specifications 10 CAN identifiers LIN bus Ethernet Serial bus 11 bit or 29 bit identifiers Motorola or Intel format Unlimited number of identifiers Bit wise operator 1; configurable as master or slave 1 at 100 Mbit/s RS232 serial link (for Supervisor) 10.6 Power Supply Supply Voltage 6.0 to 22 V 10.7 Dimensions Length x Width x Height Weight 197 x 183 x mm (w/o connectors) 1,190 g Bosch Motorsport PowerBox PBX / 60
60 PowerBox PBX 180 Installation and Users Guide Firmware and Tool Version 060 7/14/2015
Transmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
DeviceNet Bus Software Help for Programming an Allen Bradley Control System
FBP FieldBusPlug V7 DeviceNet Bus Software Help for Programming an Allen Bradley Control System DeviceNet Software Help for Programming an Allen Bradley Control System Contents Page General Purpose...
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
User and installation manual
User and installation manual aquaero 5 The information contained in this manual is subject to change without prior notice. All rights reserved. Current as of April 2011 ENGLISH: PAGE 1 DEUTSCH: SEITE 13
Keep it Simple Timing
Keep it Simple Timing Support... 1 Introduction... 2 Turn On and Go... 3 Start Clock for Orienteering... 3 Pre Start Clock for Orienteering... 3 Real Time / Finish Clock... 3 Timer Clock... 4 Configuring
OPENUPS. 6-30V Intelligent Uninterruptible Power Supply. Installation Guide. Version 1.0f P/N OPENUPS-06
OPENUPS 6-30V Intelligent Uninterruptible Power Supply Installation Guide Version 1.0f P/N OPENUPS-06 Before you start Please take a moment and read this manual before you install the OPENUPS. Often times,
PRO PLM Installation Instructions
PRO PLM Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
mdm-mp3 minidirector with MP3 Player
minidirector with MP3 Player User Manual December 15, 2014 V1.02 Copyright Light O Rama, Inc. 2007, 2008 Table of Contents Introduction... 4 What s in the Box... 4 Hardware Utility Version... 5 Important
K-Type Thermocouple Sensor User s Guide
K-Type Thermocouple Sensor User s Guide 1 TABLE OF CONTENTS: 1 INTRODUCTION... 2 2 TYPICAL APPLICATION:... 2 3 INSTALLATION RULES:... 2 3.1 Connecting the sensor to M1/MD4 data logger:... 2 3.2 Connecting
Parts List. Navigation
Parts List quantity description 1 LCD-200 Display 1 LCD-200 Display cable 1 CD-ROM 2 dual lock or velcro 1 1GB SD card (optional) 1 CAN termination plug Navigation Main Menu Begin Log/Stop Log page 4 Log
Software User Guide UG-461
Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment
Introduction. Drenth Motorsport Gearboxes Fleuweweg 10 7468 AG Enter The Netherlands Phone: +31 (0)547 38 26 96 Fax: +31 (0)547 38 20 65
25.03.0023 Introduction The display comes with a software application. With the software application information shown on the display can be adjusted. There are different modes to adjust: the shape of
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate
SPC-1. Single Point Controller. Operation Manual
SPC-1 Single Point Controller Operation Manual NOTICE: PPM Technology Limited shall not be liable for errors that may appear herein or for incidental or consequential damages in connection with or arising
WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness
WIRING HARNESS FOR AS635P4 ANTENNA NOT USED 5 PIN WHITE PLUG 2 PIN WHITE PLUG GREEN - PARKING BRAKE INPUT (-) BLUE - NOT USED 3 PIN BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness
L5354 ControlNet Communications Interface
L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or
PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version 2.1.0 (2014-01-16)
PCAN-MicroMod Universal I/O Module with CAN Interface User Manual Document version 2.1.0 (2014-01-16) Products taken into account Product Name Part number Model PCAN-MicroMod IPEH-002080 with firmware
Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts
Rubbermaid Medical Solutions Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts REVISED FEBRUARY 25, 2010 Filename: Cart Interface Installation & Control Board
Copley Camming User Guide
Copley Camming User Guide P/N 95-00501-000 Revision 2 June 2008 Copley Camming User Guide. TABLE OF CONTENTS About This Manual... 5 1: Operational Overview... 7 1.1: Host System Requirements... 8 1.2:
Hydras 3 LT Quick Start
Catalog Number 6234218 Hydras 3 LT Quick Start SOFTWARE MANUAL December 2005, Edition 2 Hach Company, 2005. All rights reserved. Printed in the U.S.A. Catalog Number 6234218 Hydras 3 LT SOFTWARE MANUAL
13-1. This chapter explains how to use different objects.
13-1 13.Objects This chapter explains how to use different objects. 13.1. Bit Lamp... 13-3 13.2. Word Lamp... 13-5 13.3. Set Bit... 13-9 13.4. Set Word... 13-11 13.5. Function Key... 13-18 13.6. Toggle
DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual
DMX-K-DRV Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Manual page 1 rev 1.33 COPYRIGHT 2007 ARCUS, ALL RIGHTS RESERVED First edition, June 2007 ARCUS TECHNOLOGY copyrights this document.
How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.
How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers. OMEGALOG Help Page 2 Connecting Your Data Logger Page 2 Logger Set-up Page 3 Download Data Page 8 Export Data Page 11 Downloading
Building a Simulink model for real-time analysis V1.15.00. Copyright g.tec medical engineering GmbH
g.tec medical engineering GmbH Sierningstrasse 14, A-4521 Schiedlberg Austria - Europe Tel.: (43)-7251-22240-0 Fax: (43)-7251-22240-39 [email protected], http://www.gtec.at Building a Simulink model for real-time
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.
Preliminary TECHNICAL DATASHEET #TDAX020700 HYDRAULIC VALVE CONTROLLER 24 I/O 5 Analog and 6 Digital Inputs 1 Temperature Sensor and 1 RPM Sensor Interface 2 PWM Inputs 6 Proportional and 4 ON/OFF Current
SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming
Somfy Digital Network (SDN) Installation and Programming SSoomffyy SSyysst teemss IInncc.. 1 Table of Contents 1 General Information and Features... 3 1.1 ILT2 Motor... 3 1.2 SDN Switches... 4 1.3 ILT2
User Manual. Thermo Scientific Orion
User Manual Thermo Scientific Orion Orion Star Com Software Program 68X637901 Revision A April 2013 Contents Chapter 1... 4 Introduction... 4 Star Com Functions... 5 Chapter 2... 6 Software Installation
Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs
Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs AN033101-0412 Abstract This describes how to interface the Dallas 1-Wire bus with Zilog s Z8F1680 Series of MCUs as master devices. The Z8F0880,
ECU MS 3 Sport GT3 Cup. Quick Start Manual
ECU MS 3 Sport GT3 Cup Quick Start Manual V1.0 11/6/2015 Table of Contents Table of Contents 1 Welcome... 3 1.1 Hardware Checklist... 3 1.2 Hardware Installation... 3 1.3 Software Installation... 3 2 Tools:
Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4
Mini CNC Interface for LPT Port Version 4 Product Brief This breakout-board is designed to connect up to four stepper or servo drives to the parallel port of a PC. This requires the use of a CNC controller
Data Analysis Software
TRAKPRO Data Analysis Software User s Manual November 1996 P/N 1980200 Rev. D TSI Incorporated TRAKPRO Data Analysis Software User s Manual November 1996 P/N 1980200 Rev. D SHIP TO: TSI Incorporated 500
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
DAKTON µ BOX MANUAL µbox User Manual 1
µbo User Manual 1 DAKTON µ BO: compact data logger and sensor µ BO is a sensor and a data logger together. It records data processed by DAKTON DASHBOARD with the addition of lateral and longitudinal accelerations.
INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS
3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS INSTALLATION MANUAL Before you begin the installation Read the INSTRUCTIONS! Always use a multi-meter when verifying vehicle wiring. Before mounting the
HyperAccess Access Control System
Control System We manufacture, an advanced PC based access control solution that will give you control over who has access to your building. With you can control access on hundreds of doors for up to 10,000
DASH2 General Layout. Figure 1: DASH2 general layout
Introduction Congratulations on your purchase of a DASH2 display unit from Race Technology. This is an advanced, feature-packed display system, designed to be compact, robust and water resistant. Make
Ordering Part Numbers:
TECHNICAL DATASHEET #TDAX021500 HYDRAULIC FAN CONTROLLER Application Platform 3 erature Sensors 4 Digital Command Interfaces 1 PWM Input and 1 Analog Input 1 Proportional or ON/OFF Current Output RS232
Install the DeviceNet Module using the following procedure:
Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from
NX Series Inverters. HVAC Pocket Programming Guide
NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product
AXIS Camera Station Quick Installation Guide
AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera
SYSTEM 45. C R H Electronics Design
SYSTEM 45 C R H Electronics Design SYSTEM 45 All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, & A outputs. Independent 25
Instruction book IQAN-MDM menu system
SETTINGS Instruction book IQAN-MDM menu system Publ.no HY17 8363/UK Edition 0905 M MODE + - PROPERTIES 24,00 V MEASURE SETTINGS INFORMATION Contents Contents 1 Introduction......................................................3
EVAL-UFDC-1/UFDC-1M-16
Evaluation Board for Universal Frequency-to- Digital Converters UFDC-1 and UFDC-1M-16 EVAL-UFDC-1/UFDC-1M-16 FEATURES Full-Featured Evaluation Board for the Universal Frequency-to-Digital Converters UFDC-1
Corsair Link v2.4 Manual. Initial Set-up. Placing devices within the chassis
Corsair Link v2.4 Manual Initial Set-up Placing devices within the chassis When you first start up Corsair Link, there will be a list of auto-detected devices on the left column. You can drag and drop
1R / 4-BUTTON SERIES
Button 1 1R / 4-BUTTON SERIES VEHICLE SECURITY SYSTEM Standard Features: Two 4-Button Remote Transmitters Status indicator (LED) Valet / override switch Multi-tone siren Dual stage impact detector Remote
Manual. EN Appendix. Blue Solar PWM Pro setup and monitoring software
Manual EN Appendix Blue Solar PWM Pro setup and monitoring software EN Appendix Contents 1. Region and language settings 2 2. Download the software 2 3. UnRAR the software 2 4. Install the software 3
SKP16C62P Tutorial 1 Software Development Process using HEW. Renesas Technology America Inc.
SKP16C62P Tutorial 1 Software Development Process using HEW Renesas Technology America Inc. 1 Overview The following tutorial is a brief introduction on how to develop and debug programs using HEW (Highperformance
SYSTEM 4C. C R H Electronics Design
SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25
ETS4 Diagnostics. KNX Association
ETS4 Diagnostics Table of Contents 1 Diagnostics and fault location... 3 2 Diagnostics: Individual addresses...... 4 2.1 Devices in Programming Mode... 4 2.2 Checking if an address exists and locating
Talon and Talon SR User Manual
Talon and Talon SR User Manual Brushed DC motor controller Version 1.3 Cross the Road Electronics, LLC www.crosstheroadelectronics.com Cross The Road Electronics, LLC Page 1 4/2/2013 Device Overview Clear,
M O D U L E - 7 E Model CS-Caliprompter Operator s Manual
O P E R A T I O N S A N D P R O C E D U R E S F O R C S - C A L I P R O M P T E R A N D A C C E S S O R I E S Model CS-Caliprompter Visual screen display allows easy step-by-step operation On-site programming
GPS NTP TIME SERVER Rack Version V2.2x
GPS NTP TIME SERVER Rack Version V2.2x Device Description: GPS NTP Time Server is designed to synchronize local time and date of network devices such as PCs, routers. Devices synchronize their local time
Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide
Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide Sensors LCD Real Time Clock/ Calendar DC Motors Buzzer LED dimming Relay control I2C-FLEXEL PS2 Keyboards Servo Motors IR Remote Control
PDA Software Manual For the Windows CE and Mobile Operating Systems
PDA Software Manual For the Windows CE and Mobile Operating Systems Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560,
9452/9453 Installation and User Guide
9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and
Plena Voice Alarm System. Software Manual Configuration Software
Plena Voice Alarm System en Software Manual Configuration Software Plena Voice Alarm System Software Manual Table of Contents en 3 Table of Contents Table of Contents...3 1. Introduction...7 1.1 Purpose...7
NortechCommander Software Operating Manual MAN-00004 R6
NortechCommander Software Operating Manual MAN-00004 R6 If the equipment described herein bears the symbol, the said equipment complies with the applicable European Union Directive and Standards mentioned
CashFlow Programming Module CPM
CashFlow Programming Module CPM Installation & User Guide GB REV G4 08/08/2006 Table of Content Table of Content... 2 CashFlow Programming Module (CPM)... 4 What is a CPM?... 4 CPM Identification... 4
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
CRE Monitor Instructions Manual
CRE Monitor Instructions Manual CRE TECHNOLOGY believes that all information provided herein is correct and reliable and reserves the right to update at anytime. CRE TECHNOLOGY does not assume any responsibility
Page 1 S5.5 Monitoring Software Manual Rev 1.2 for Software Ver 1.0
Trantec S5.5 Monitoring Software Manual Initial Setup Minimum PC Requirements 1.6 GHz CPU, 256 MB Memory, 1 available USB port, Windows XP Recommended PC >2.0 GHz CPU, 512 MB (XP) 1 GB (Vista) memory,
User Manual Software for DSL Digital Speed Switch
User Manual Software for DSL Digital Speed Switch Software version from 1.0.1 Baumer Hübner GmbH Max-Dohrn-Str. 2+4 D-10589 Berlin Phone +49 (0)30 690 03-0 Fax +49 (0)30 690 03-104 [email protected]
OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
How To Control A Car Alarm On A Car With A Remote Control System
MODEL CA100 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM Black Antenna Wire 6 Pin 6 Pin Mini Connector Valet Switch Blue LED Indicator Blue Wire: (-) 200mA Unlock
User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600
User Manual Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600 2 1. Introduction 1. Introduction 1.1 Introduction Thank you for choosing an EFOY product. Please read
with Electronic Assistant
TECHNICAL DATASHEET #TDAX100200 BLDC Motor Drive Drives a 12V, 24V or 48V BLDC motor Bidirectional, up to 25A Smooth speed control using Hall Sensors CAN (SAE J1939) with Electronic Assistant Features:
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
VEHICLE THEFT/SECURITY SYSTEMS
DN VEHICLE THEFT/SECURITY SYSTEMS 8Q - 1 VEHICLE THEFT/SECURITY SYSTEMS TABLE OF CONTENTS page GENERAL INFORMATION INTRODUCTION...1 VEHICLE THEFT SECURITY SYSTEM....1 ENABLING...1 ARMING...1 DISARMING...2
Part Number 129777-01 Revision A, January 1996. 3500 Monitoring System Rack Configuration and Utilities Guide
Part Number 129777-01 Revision A, January 1996 3500 Monitoring System Rack Configuration and Utilities Guide Copyright 1995 Bently Nevada Corporation All Rights Reserved. No part of this publication may
WIFI OBD GPS Tracker T356 User Manual
WIFI OBD GPS Tracker T356 User Manual Version:1.000 http://www.ulbotech.com [email protected] Document Title T356 User Manual Version 1.000 Date 2015-04-02 Status Release General Notes Ulbotech offers this
Universal Simple Control, USC-1
Universal Simple Control, USC-1 Data and Event Logging with the USB Flash Drive DATA-PAK The USC-1 universal simple voltage regulator control uses a flash drive to store data. Then a propriety Data and
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication
USER S MANUAL. AXIS Mobile Monitor
USER S MANUAL AXIS Mobile Monitor AXIS Mobile Monitor Overview Main window Main menu Find Devices Find Devices menu Monitor window Monitor menu Sequence window Sequence menu How to Use AXIS Mobile Monitor
[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]
FG085 minidds Function Generator Manual of Operation Applicable Models: 08501, 08501K, 08502K, 08503, 08503K Applicable Firmware Version: 1 ) 113-08501-100 or later (for U5) 2 ) 113-08502-030 or later
10 Thomas, Irvine, CA 92618 USA Tel: (949) 465-0900 Fax: (949) 465-0905 Toll Free: (800) 23 FUTEK
Table of Contents Software Overview... - 4 - Product Key... - 5 - Model Selection... - 6 - Device Selection... - 7 - Menu... - 8 - File... - 8 - Edit... - 8 - View... - 8 - Format... - 8 - Help... - 9
oxigen system Slot.it oxigen timing RMS installation Dongle driver installation 1/ 11 Race Management Software
1/ 11 Slot.it oxigen timing RMS installation To install the Slot.it oxigen timing-rms software, follow these steps: 1. download the O2_chrono_installer.zip file from Slot.it ftp site; 2. unzip the downloaded
Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction 1. 2. Software Installation 2
1. Introduction 1 2. Software Installation 2 2.1 System Requirements 2 2.2 TroxMConnect Installation 2 2.3 Connection to the PC 3 3. TroxMConnect Description 4 3.1 Starting the Software 4 3.2 Layout 4
Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205]
Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205] Users Manual Robokits India [email protected] http://www.robokitsworld.com Page 1 Bluetooth + USB 16 Servo Controller is used to control up to
Contents Installing the ucal Software on your PC/Laptop ucal Programmer Version Connecting the ucal Programmer to your PC/Laptop
Contents Installing the ucal Software on your PC/Laptop 1 ucal Programmer Version 1 Connecting the ucal Programmer to your PC/Laptop 1 Optional USB Adapter Kit (for ucal) 1 Installing the USB Driver for
STIM202 Evaluation Kit
Table of contents: 1 FEATURES... 2 2 GENERAL DESCRIPTIONS AND SYSTEM CONTENTS... 2 3 SYSTEM REQUIREMENTS... 2 4 GETTING STARTED... 3 4.1 INSTALLATION OF NI-SERIAL CABLE ASSEMBLY DRIVER... 3 4.2 INSTALLATION
S4000TH HART. HART Communication Manual
HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by General
INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200
INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200 FUSION CULTURE TABLE OF CONTENTS There s no point doing something if no one notices. We ve always believed the way to make things happen is by getting
The Child Reminder System Installation Manual
The Child Reminder System Installation Manual Revised June, 2006 Detailed installation information can be found at www.childreminder.com. Get through your installation quickly and easily by calling 1-888-330-6786
CONTENTS. Section 1 Document Descriptions... 3. 1.1 Purpose of this Document... 3. 1.2 Nomenclature of this Document... 3
CONTENTS Section 1 Document Descriptions... 3 1.1 Purpose of this Document... 3 1.2 Nomenclature of this Document... 3 Section 2 Solution Overview... 5 2.1 General Description... 5 2.2 Hardware and Software
Programmer/Controller
Systems Plus START 7 8 9 envirotronics ALARM STOP 4 5 6 ALARM ACK Instrument Manual Systems Plus Programmer/Controller OFF HELP 1 2 0 3. ENTER ALARM RESET DEL Revision 6 9/12/97 Table of Contents 2 Menu
MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card
Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully
Real Time Clock USB Evaluation Board V3.0
Real Time Clock USB Evaluation Board V.0 Application Note February 9, 008 RTC EVB Intersil RTC Devices Supported Introduction This evaluation board provides a platform for testing Intersil Real Time Clock
The ACD pro replaces any resistance based controller and is suitable for nearly any motor within the current rating.
1. Main Features Non contact trigger. Minimal maintenance. Microcontroller- based PWM control. New braking behavior and high acceleration. Adjustable brake sensitivity and choke. Suitable for all motors
Vansco Multiplexing Module VMM1615. User Guide HY33-5008-IB/US UG-VMM1615-154200-201309-003
Vansco Multiplexing Module VMM1615 User Guide HY33-5008-IB/US UG-VMM1615-154200-201309-003 Parker Hannifin Corporation Electronic Controls Division 1305 Clarence Avenue Winnipeg, MB R3T 1T4 Canada office
EasyMP Monitor Operation Guide Ver.4.50
EasyMP Monitor Operation Guide Ver.4.50 Notations Used in This Guide The following table shows the symbols used in this manual, along with descriptions of what they mean. Attention s Indicates procedures
SENSORED BRUSHLESS MOTOR & SPEED CONTROLLER COMBOS
SENSORED BRUSHLESS MOTOR & SPEED CONTROLLER COMBOS OPERATING INSTRUCTIONS Please keep for future reference Thank you for purchasing this Exceed brushless motor and speed controller combo. We are sure you
INSTRUMENT PANEL. 1995 Volvo 850 DESCRIPTION & OPERATION. 1995-96 ACCESSORIES & EQUIPMENT Volvo Instrument Panels
INSTRUMENT PANEL 1995 Volvo 850 1995-96 ACCESSORIES & EQUIPMENT Volvo Instrument Panels 850 WARNING: When working around steering column and before performing repairs, disconnect and shield battery ground
Troubleshooting Guide
PYRAMIX 8 Troubleshooting Guide Merging Technologies Le Verney 4, CH-1070 Puidoux Switzerland www.merging.com/horus T : +41 21 946 04 44 F : +41 21 946 04 45 HORUS Make sure that you are running the latest
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
DG-100 Data Logger User Manual. Version 1.2
DG-100 Data Logger User Manual Version 1.2 DG-100 page 2 Table of Content 1 Introduction and Features... 3 Introduction...3 Features...4 2 Specifications... 5 System specification...5 GPS specification...6
