FIRE AND SAFETY REGULATIONS
|
|
|
- Alannah Powers
- 9 years ago
- Views:
Transcription
1 FIRE AND SAFETY REGULATIONS Fire Prevention reserves the right to make any final decisions regarding the outlined requirements, according to Section of the Municipal Code of Chicago on Fire Prevention. Prior to the show opening and at any time during the event, the Fire Marshal may inspect the booths to ensure these requirements are met. If they are not, adjustments can be costly, and if a booth imposes a significant fire hazard, it will be prohibited from exhibiting. If you have any questions or need fire code information please call the Fire & Safety Manager at (312) Booth Staging In addition to equipment and furniture placed within a booth space, Exhibitors are allowed to stage the following items: Boxed or loose product, materials or literature. Fiber cases used to ship pop-up displays. Personal items such as luggage, purses, briefcases or coats. The following restrictions must be observed when staging these additional items: The amount of product, materials or literature that may be staged within a booth space must not exceed a one-day supply. Items may be placed either in a display case, on a counter, on a shelving unit, in a closet, on a table, under a table or stacked neatly within the booth space. Items that are placed under a table must not protrude outside the table dimensions. Items that are stacked must not create a tripping hazard or hamper easy movement within the booth space. Items may not be placed on or within six inches of floor ports, electrical wiring or cabling. Pallets, empty crates, cartons and boxes may not be stored in the booth space. Staging will not be allowed behind the back wall of the booth and behind the drape within the booth. Fire Safety personnel will patrol the exhibit area. If anyone is in violation a written notice will be given to the exhibitor. Fire Retardancy Booth construction and decoration materials must be fire retardant. It is suggested that a certificate of retardancy be available at the show to prevent the need for possible on-site testing of the material. Fabrics must pass the NFPA-701 Code, and all other construction and decoration materials must pass the NFPA-703 Code as well as the UL-1975 test. General guidelines for material fire retardancy include: Backdrops, tents, canopies, dust and table covers, drapes and similar fabrics: These fabrics can often be made fire retardant by a dry cleaner that can issue a certificate of fire retardancy. Suppliers and/or display manufacturers can also provide a certificate included with the materials. Corrugated cardboard/display boxes: These materials can best be made fire retardant at a factory. Wood and wood by-products: If wood materials are not sufficiently fire retardant, a certified fire retardant specialist using pressure impregnation or similar impregnation method must treat them. Polyurethane foam, plastic and similar products. 19
2 Open Flame Devices Used for illumination or decoration, such as candles, gelled alcohol fuel fire bowls, firepots or fireplaces must comply with the following: Prior notification and review by the McCormick Place Fire Safety Manager, the Fire Prevention Bureau, the Fire Marshal and Show Management. Must be contained inside a non-combustible enclosure that totally encapsulates the flame providing a measure of safety to the public. Must be positioned on a non-combustible surface with 24 inch clearance of the flame device from any combustibles and booth back wall. Must have a mechanism available to quickly and safely extinguish the flame. Must have at least one multipurpose fire extinguisher rated minimum 2 A :10- B:C strategically located with the booth. Booth personnel should be familiar with the operation of the fire extinguisher. Booth personnel must be in attendance whenever the device is in use. Maximum one day supply of the replacement fuel allowed in booth. Device must be allowed to cool before refueling. Flame must be extinguished ½ hour prior to closing. Hazardous Demonstration/Display Materials/Pyrotechnics When designing demonstrations and displays, note that the following devices require pre-approval by McCormick Place and the Chicago Fire Department. Lasers, open flames (including candles) Smoke-producing devices Indoor Pyrotechnics have special permitting procedures through the City of Chicago Fire Prevention Bureau. Contact the Assistant Director of Fire Safety. Heating appliances Welding, brazing or cutting equipment Radioactive materials Compressed gas or compressed liquid cylinders if applicable used in the booth must be securely anchored to prevent toppling. Gasoline, kerosene or other flammable, toxic liquid, solid or gas o A limited supply of these fuels may be stored in the demonstration device, but cannot be stored overnight. o All fuel transfers must use safety cans. When displaying a flammable or combustible labeled product, the display container shall be empty. Up to two aerosol cans may be used for demonstration purposes only. Approval requests must be sent in 60 days before move-in of the event. The request must state how the demonstration will avoid hazards to people or nearby objects. Plexiglas or similar protection is required whenever sparking may occur. Fire extinguishers will also be required. Any chemical, substance or material deemed hazardous by OSHA requires pre-approval and must be accompanied with the appropriate Material Safety Data Sheet (MSDS). McCormick Place Fire Safety Office will need copies of the MSDS before the materials arrive. 20
3 Prohibited Materials The following items are fire-hazardous and prohibited in McCormick Place: All flammable compressed gases, such as propane and butane Explosives and live ammunition Untreated Christmas trees, cut evergreens or similar trees Fireplace logs and similar materials Charcoal Untreated mulch, Hay, Straw, Bamboo and Spanish moss Cooking and Heat-Generating Devices If cooking or heating appliances will be used, they must be powered electrically or by natural gas. Stoves and heaters for booth usage must be UL listed/approved and also be adequately ventilated. Nothing combustible may be placed near any heat-producing appliance. A UL listed/approved, 2 A :10 B : C ABC-type fire extinguisher is required in such exhibits. Fire Hose Cabinets, Pull Stations, Aisles and Exits Each of these fire safety supports must be visible and accessible at all times. Adjustments to space and equipment may be required. Chairs, tables and other display equipment must be clear of all aisles, corridors, stairways and other exit areas. Vehicle Displays Any vehicle or other apparatus that has a fuel tank and is part of a display, is required to be equipped with a locking (or taped) gas cap and can contain no more than 1/8 tank of fuel. Once the vehicle has been positioned, it cannot be moved until move-out begins, without prior approval by the McCormick Place Fire Safety Manager or Designee. Battery cables must be disconnected once the vehicle is positioned. The engine cannot be operated during show hours. Refueling must be done off property. Hazardous Materials Management Neither McCormick Place Housekeeping Department nor your official service contractor manages hazardous material removal. However, the McCormick Place Event Management Department can provide contractor names specializing in this service. Exhibitors are responsible to make their own arrangements. 21
4 Multi-Level Booths or Ceilings (including tents) Double-decker booths or booths with ceilings (including tents) were previously required to be equipped with fire safety devices. However, our Fire Safety Department and major show contractors have worked with the Chicago Fire Department to develop specific codes for the trade show environment that would offer a safe and cost-effective alternative to sprinklers. These specific requirements apply to all exhibits that have a ceiling or second story. Booths fall into one of the five following booth formats: Format 1: Exhibits with two stories under 225 square feet Format 2: Exhibits with two stories at or over 225 square feet Format 3: Exhibits with ceilings under 225 square feet Format 4: Exhibits with ceilings at or over 225 square feet Format 5: Multiple-level exhibits, which require automatic sprinklers or any of the above exhibits with installed automatic sprinklers. Separate fire code items apply. For booth formats 1 4, you will need to comply with the fire code items marked yes on the following table: Fire Code Compliance Exhibits with Multiple Levels or Ceilings Fire Code Item Booth Format Max. Dimensions Yes Yes No Yes 2. Second Level Yes Yes No No 3. Exit Stairways Yes Yes No No 4. Smoke Detectors Yes Yes Yes Yes 5. Fire Extinguishers Yes Yes Yes Yes 6. Posted Certificate of Fire Retardancy No Yes No Yes 7. Certified Approval Yes Yes No Yes 8. Fire Marshal Review Yes Yes Yes Yes For exhibits using automatic sprinklers, the amount and type of sprinkler coverage needed depends on the booth specifications. If automatic sprinklers are preferred, or are required, contact our Fire Safety Office to discuss your options. 22
5 Fire Code Items for Multiple Level Booths Maximum Dimensions: To avoid the sprinkler requirement, your exhibit must be less than or equal to 2 levels high (maximum 30-foot elevation) or 5,000 square feet of enclosed area. Second Level: Second levels must remain open and uncovered. If they are covered, sprinkler protection will be required. Booths with a third level or more must also have special sprinkler coverage. Staircases: Staircases between levels must be in compliance with the Americans With Disabilities Act and meet the following requirements: o Minimum of 3 feet in width o Provide a handrail on at least one side o Provide handrails a maximum of 1-1/2 inches in circumference and turned into walls o Not be spiral or winding o If the top deck is designed to hold over 10 people, or exceeds 1,200 square feet in area, a second staircase is required which must be remote from the main staircase and meet the same construction requirements. Smoke Detectors: All areas under the second level or ceiling, including closets, need to be equipped with a UL approved (or similarly approved), battery-operated smoke detector. If this space is enclosed after hours, the smoke detector must be audible outside the enclosed area. Fire Extinguishers: A UL-approved (or similarly approved) 2-1/2 pound ABC-type fire extinguisher must be posted in a clearly visible and readily accessible area for each 500 square-foot enclosure. Posted Certificate of Fire Retardancy: A certificate verifying the fire retardancy of your booth construction materials must be posted in a conspicuous place within the exhibit. Certified Approval: After the booth has been designed, the blueprints must be approved and stamped by a licensed professional structural engineer. These blueprints should include dimensions and an isometric rendering. This approval applies to all booth formats outlined previously. Fire Safety Review: Send stamped blueprints to McCormick Place for review with the Fire Safety Division and by the Chicago Fire Department, Fire Prevention Bureau at least 60 days before the show opens to allow sufficient time for any needed corrections. Be sure that plans show dimensions and an isometric rendering of your exhibit. In addition, all areas requiring sprinkler protection must be highlighted. If plans are not provided on time, it may cause delays or disapproval of your booth to occur during the pre-show fire inspection. Fire Guards: Once a multiple level booth or a booth with a ceiling is built and completed, and whenever the exhibit or show is closed for business, special fire watch coverage is required. Use of individuals designated as fire guards is subject to prior approval by the McCormick Place Assistant Director of Fire Safety. Americans with Disabilities Act: All exhibits must comply with the ADA. For information on compliance, contact the McCormick Place Assistant Director of Fire Safety. 23
The Fire Safety Manager at 312 791 6079 (FAX 312 791 6013) can answer any questions or provide a set of fire code information.
FIRE SAFETY REGULATIONS Fire Prevention reserve the right to make any final decisions regarding the outlined requirements, according to Section 2 36 220 of the Municipal Code of Chicago on Fire Prevention.
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or comments regarding the
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011, Updated March 2012 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or
Medicine Hat Fire Department. Special Event Requirements. medicinehat.ca/fire. August 2012
Medicine Hat Fire Department Special Event Requirements August 202 medicinehat.ca/fire The following is a standard guide for event organizers to ensure occupant safety and compliance with the Alberta Fire
Fire Regulations for Exhibitors
The purpose of these requirements is to maintain an acceptable level of fire safety within the Metro Toronto Convention Centre. The fire protection systems built into the Convention Centre have been designed
OCFRD TENT STANDARD 6000. This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.
1. Authority Orange County Fire Rescue Department Tents & Membrane Structures Office of The Fire Marshall - 109 E. Church Street, Lower Level - Orlando, Florida 32801-3319 Phone: 407-836-0004 Fax: 407-836-8310
Orange County Fire Rescue Division Fire Loss Management Bureau 109 East Church Street Lower Level Orlando, Florida 32801-3319
Standard 6005 Orange County Fire Rescue Division Fire Loss Management Bureau 109 East Church Street Lower Level Orlando, Florida 32801-3319 Orange County Fire Loss Management Bureau Standard 6005 AUTHORITY
Fire and Life Safety Requirements for Special Events and Temporary Use of the Facilities at the Kitsap County Fairgrounds.
Fire and Life Safety Requirements for Special Events and Temporary Use of the Facilities at the Kitsap County Fairgrounds. PURPOSE This document is developed to assist event planners and responsible parties
LOS ANGELES CITY FIRE DEPARTMENT
LOS ANGELES CITY FIRE DEPARTMENT Division 5 Permit LOCATION INFORMATION FD USE ONLY Date of Use: Date Granted PERMIT # Date Expires Name Phone#: City: Los Angeles State: California Zip: 90089 CONTRACTOR
INFORMATION BULLETIN Bulletin No. 2005-01 Bureau of Fire Prevention Date: June 10, 2005 Revised: March 8, 2007
SAN FRANCISCO FIRE DEPARTMENT DIVISION OF FIRE PREVENTION & INVESTIGATION INFORMATION BULLETIN Bulletin No. 2005-01 Bureau of Fire Prevention Date: June 10, 2005 Revised: March 8, 2007 SUBJECT: Fire Department
General Fire Code Requirements Within Commercial Tenant Spaces
FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding
FIRE DEPARTMENT REGULATIONS FOR TRADE SHOW EXHIBITORS
FIRE DEPARTMENT REGULATIONS FOR TRADE SHOW EXHIBITORS A. Inherently Fire Retardant or Flame Retardant Treatment 1. All decorations, drapes, signs, banners, plastic displays, hay, straw, moss, split bamboo
BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS
DCD-0304 Identification # Rev. 9/08 County Date of Inspection NAME OF OPERATION BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS ADDRESS TELEPHONE: CITY STATE ZIP BUILDING INSPECTORS CERTIFICATE
SPECIAL EVENTS CHAPTER 17
CHAPTER 17 SPECIAL EVENTS SECTION 1701 GENERAL 1701.1 Scope. Special events including trade shows and exhibitions, outdoor assembly events, outdoors mazes, special amusement buildings, and special scaffolding
Special events and tents Fire and life safety requirements
Special events and tents Fire and life safety requirements Section A - Temporary Use Occupancies or Operations Fire and Life Safety Requirements In order to provide a standard method of inspection of temporary
Exhibit Space & Booth Layout Guidelines
Exhibit Space & Booth Layout Guidelines Exhibit Space & Booth Display Rules The following display rules have been designed using the IAEE (International Association of Exhibitions and Events) guidelines
ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600
OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done
BOOTH CONSTRUCTION. Installation & Dismantle
Installation & Dismantle Exhibit Installation Installation days and hours are as follows: Wednesday, November 11 and Thursday, November 12 7:30 AM 7:00 PM Friday, November 13 7:30 AM 10:00 PM Every individual
PLACES OF ASSEMBLY CHAPTER 17
CHAPTER 17 PLACES OF ASSEMBLY SECTION 1701 GENERAL 1701.1 Scope. Places of assembly, including trade shows and exhibitions, outdoor assembly events, outdoors mazes, special amusement buildings and special
Orange County Convention Center Rules and Regulations
Orange County Convention Center Orlando, FL Orange County Convention Center Rules and Regulations Guidelines for All Exhibits For the protection of our facility and for those guests either working or attending
Dennis Fire Department Fire Prevention Mark Dellner Fire Chief
Dennis Fire Department Fire Prevention Mark Dellner Fire Chief FIRE SAFETY INSPECTION GUIDELINES FOR COMMERCIAL PROPERTIES (MA Fire Prevention Regulations 527 CMR, MGL Chapter 148) FIRE PREVENTION CHECKLIST-
Code Compliance Guideline: Swimming Pool Chemicals
A publication of Fairfax County, Virginia CODE COMPLIANCE GUIDELINE SWIMMING POOL CHEMICALS AND FIRE SAFETY REQUIREMENTS RELATED TO POOL OPERATIONS This publication outlines the Fire Prevention Code requirements
CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau
CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau g GUIDELINE FOR SAFETY REQUIREMENTS FOR HAUNTED HOUSES PURPOSE This guide is intended to provide safety standards and regulations for the construction
ARE YOU AN ISLAND OR IN-LINE BOOTH?
RULES & Page 1 ARE YOU AN ISLAND OR IN-LINE BOOTH? An island booth is defined as a booth that has an aisle between it and all of its neighbors. All other booths are considered in-line booths. If a booth
EXHIBIT DISPLAY INFORMATION
EXHIBIT DISPLAY INFORMATION DISPLAY GUIDELINES The Allocation Procedures and Display Guidelines are a part of the Terms, Rules and Regulations of the contract. By signing the contract, exhibitors agree
A. Fire Protection Plan. B. Access and Parking
Standards for Construction Site Fire Safety For Use by Unidocs Member Agencies or where approved by your Local Jurisdiction Authority Cited: California Fire Code (CFC) These standards are intended to prescribe
Exhibit Space & Booth Layout Guidelines
Exhibit Space & Booth Layout Guidelines Exhibit Space & Booth Display Rules The following display rules have been designed using the IAEE (International Association of Exhibitions and Events) guidelines
Safe Operating Procedure
Safe Operating Procedure (Revised 07/09) HOT WORK PERMIT OPERATIONS (For assistance, please contact EHS at (402) 472-4925, or visit our web site at http://ehs.unl.edu/) Authority In recognition of the
Guidelines for Booth Display/ Rules & Regulations
Guidelines for Booth Display/ Rules & Regulations The Car Wash Show requires that Exhibitors with island or peninsula booths 400 square feet and above must submit a floor plan with dimensions, including
FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS
FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS The attached self-inspection form is intended for staff use at regular, frequent intervals. It should not take the place of two other vital measures
FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No
General Inspection FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS 1. All Floors (inspect from top floor to basement): Yes are fire exits and directional signs properly illuminated? is the emergency
Section III Hazardous Materials Management
Section III Hazardous Materials Management This section of the Everyday Hazmat User s Training Guide covers various types of hazardous materials commonly found in the USDA Forest Service. Federal regulations
PLAN REVIEW GUIDE FOR FIRE ALARM
PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical
Guidelines for Display Rules & Regulations
Guidelines for Display Rules & Regulations You are reminded that a booth design, including flooring and fixtures, is REQUIRED in order for your company to maintain consideration for future shows. Booth
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
INTERNATIONAL FIRE CODE SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES
INTERNATIONAL FIRE CODE SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES 3103.1 General. All temporary tents and membrane structures shall comply with this section. 3103.2 Approval required. Tents
TENTS, CANOPIES AND OTHER MEMBRANE STRUCTURES
CHAPTER 24 TENTS, CANOPIES AND OTHER MEMBRANE STRUCTURES > SECTION 2401 GENERAL 2401.1 Scope. Tents, canopies and membrane structures shall comply with this chapter. SECTION 2402 DEFINITIONS 2402.1 Definitions.
NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet
This Commercial Kitchen Automatic Fire has been created to assure all documentation has been submitted to assist you in assuring proper plans and documentations has been submitted and reviewed by New Mexico
Name Of Occupancy Date. Yes No Describe
FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address
Minnesota State Department of Public Safety
Minnesota State Department of Public Safety 444 Cedar Street, Suite 145, St. Paul, Minnesota 55101-5145 Phone: 651/215-0500 FAX: 651/215-0525 TTY: 651/282/6555 Internet: http://www.fire.state.mn.us Inspection
Town of Bellingham Fire Department
Town of Bellingham Fire Department OFFICE OF THE Fire Prevention Division Captain Robidoux- [email protected] Lieutenant Bangma- [email protected] Fire Safety Inspection Guidelines for
Display Rules & Regulations CHFA WEST / CHFA EAST / CHFA QUEBEC
CHFA WEST / CHFA EAST / CHFA QUEBEC Display rules and regulations ensure that all exhibitors, regardless of exhibit size or location, enjoy an environment that is conducive to successful interaction with
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to
All You Ever Wanted to Know About Fire Extinguishers...
All You Ever Wanted to Know About Fire Extinguishers... There are basically four different types or classes of fire extinguishers, each of which extinguishes specific types of fire. Newer fire extinguishers
LAS VEGAS CONVENTION CENTER RULES AND REGULATIONS
LAS VEGAS CONVENTION CENTER RULES AND REGULATIONS CONTACT INFORMATION ARAMARK Food & Beverage Services: (702) 943 6910 COX Business: (702) 943 6500 FedEx: (702) 943 6780 Las Vegas Convention Center: (702)
FIRE PREVENTION PLAN
FIRE PREVENTION PLAN 1 FIRE PREVENTION PLAN OSHA s Fire Prevention Plan regulation, found at 29 CFR 1910.38(b) and 29 CFR 1926.24, requires Northern Clearing, Inc. to have a written fire prevention plan
FIRE SAFETY ONLINE TRAINING
INTRODUCTION This Fire Safety Training module is designed to teach you preventive measures that will eliminate or minimize causes of fire or fire hazards in the workplace, and to teach you proper emergency
HOT WORK PERMIT PROGRAM TRAINING. John Braun
HOT WORK PERMIT PROGRAM TRAINING John Braun 1.0 INTRODUCTION 1.2 Purpose The Hot Work Permit Program has been developed for University employees that work on or around hot work activities. This program
10' 16' Maximum. Backwall 5' 5'
Peninsula December 11 13, * ALL PENINSULA EXHIBITORS ARE REQUIRED TO SUBMIT ACCURATE RENDERINGS AND DIMENSIONS OF THE PENINSULA EXHIBIT TO TRADE SHOW MANAGEMENT FOR APPROVAL PRIOR TO THE SHOW. (For questions,
Exhibit Space & Booth Layout Guidelines
Exhibit Space & Booth Layout Guidelines Exhibit Space & Booth Display Rules The following display rules have been designed using the IAEE (International Association of Exhibitions and Events) guidelines
1.0 Purpose... 4. 2.0 Definitions...4. 3.0 Hot Work Operations. 5
HOT WORK PROGRAM Introduction The University of Kentucky recognizes a potential for fire from hot work operations. For that reason this program should be implemented in all departments at the University
Denver January 12-15, 2017. Exhibitor Participation Rules & Regulations
Denver January 12-15, 2017 Welcome to the Online Exhibitor Services Information Center. To use this page, click on the links below for information. use the "Top" bottun to return to the menu at the top
Exhibit Space & Booth Layout Guidelines
Exhibit Space & Booth Layout Guidelines Exhibit Space & Booth Display Rules The following display rules have been designed using the IAEE (International Association of Exhibitions and Events) guidelines
The Commonwealth of Massachusetts Executive Office of Public Safety Department of Fire Services
MITT ROMNEY GOVERNOR KERRY HEALEY LT. GOVERNOR EDWARD A. FLYNN SECRETARY The Commonwealth of Massachusetts Executive Office of Public Safety Department of Fire Services P.O. Box 1025 State Road Stow, Massachusetts
HOT WORK PERMIT PROCEDURES
COLUMBIA UNIVERSITY ENVIRONMENTAL HEALTH & SAFETY HOT WORK PERMIT PROCEDURES COLUMBIA UNIVERSITY MEDICAL CENTER February 2010 1 TABLE OF CONTENTS A. PURPOSE 3 B. SCOPE 3 C. POLICIES AND PROCEDURES 3-4
LABORATORY SAFETY INSPECTION CHECKLIST
LABORATORY SAFETY INSPECTION CHECKLIST As part of EH&S's laboratory safety survey program, we have compiled a list of the most common safety problems. This is not a list of every possible hazard, but can
HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids
Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario Fire Code, Part 4, and of the Regulations for
Flammable and Combustible Liquids. Slide 1 (of 23)
Flammable and Combustible Liquids Slide 1 (of 23) Introduction The two primary hazards associated with flammable and combustible liquids are explosion and fire Safe handling and storage of flammable liquids
SAFETY SELF-INSPECTION PROGRAM
Palm Beach State College Florida s First Public Community College SAFETY SELF-INSPECTION PROGRAM PALM BEACH STATE COLLEGE SAFETY SELF-INSPECTION PROGRAM 1. INTRODUCTION An important element of any employee
BP WIND ENERGY POLICIES AND PROCEDURES
BP WIND ENERGY POLICIES AND PROCEDURES Document Control Details 1.0 Purpose/Scope 1.1 This procedure provides the minimum requirements to be followed for the storage of flammable or combustible materials
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result
PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS
January 1997 PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS 1.0 PERMIT 1.1 After receipt of a Building Permit from the City of San Jose Building Department, submit
MONARCH FIRE PROTECTION DISTRICT
MONARCH FIRE PROTECTION DISTRICT 13725 OLIVE BLVD., CHESTERFIELD, MO 63017 314-514-0900, EXT. 309 [email protected] www.monarchfpd.org TENT / BOOTH REQUIREMENTS To help insure the safety, health
CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES
CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES Review the following information pertaining to Construction Fire Safety Planning: B.C. Building Code Sections 8.1 up to and including Subsection 8.2.3 B.C.
Guidelines for Display Rules & Regulations
BOOTH OPTIONS The following display rules and regulations will be strictly enforced by NAMM and its representatives on the show floor. They were developed by the Exhibit Designers and Producers Association
FDNY C14 Certificate of Fitness Quiz
FDNY C14 Certificate of Fitness Quiz Name: Date: 1. Who issues a New York City laboratory permit? a) Department of Environmental Protection (DEP) b) Department of Environmental Conservation (DEC) c) Occupational
SECTION FC 2706 NON-PRODUCTION CHEMICAL LABORATORIES
New York City Administrative Code - Title 29 New York City Fire Code SECTION FC 2706 NON-PRODUCTION CHEMICAL LABORATORIES 2706.1 Scope. This section shall govern the storage, handling and use of laboratory
CANTON FIRE DEPARTMENT
CANTON FIRE DEPARTMENT Dean Floyd Fire Chief FIRE SAFETY INSPECTION GUIDELINES FOR COMMERCIAL PROPERTIES FIRE PREVENTION CHECKLIST- To review prior to your inspection. 1. Is the address of your property
Requirements for Hydrogen Storage and Use
Requirements for Hydrogen Storage and Use I. INTRODUCTION Fire and Life-Safety Group (FLS) The following is a summary of the fire and building code requirements for the storage and use of hydrogen. These
Residential Fire Safety Policies
Residential Fire Safety Policies Introduction University Housing and Campus Code Compliance and Fire Safety at the City University of New York at Queens College in compliance with the Higher Education
Exhibitor Manual. Page 1
Exhibitor Manual Page 1 The Venue - Halifax, Nova Scotia, Canada The exhibit displays for the ICOE 2014 Conference will be located at: Monday, November 3 8:00am to 4:00pm Tuesday, November 4 10:15am to
Automatic fire-extinguishing systems for commercial cooking
Automatic fire-extinguishing systems for commercial cooking Leading Items First Ignited in Eating and Drinking Establishment Structure Fires, 2000-2004 Annual Averages Cooking materials, incl. food and
General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission
General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission Local Fire Alarm 064. FIRE ALARM SYSTEMS 01. Scope 02. Definitions 03.