Appendix D. Water Quality

Size: px
Start display at page:

Download "Appendix D. Water Quality"

Transcription

1 Appendix D Water Quality

2 Deadmans Run Watershed Water Quality Testing Results at 7th Street Event Date d - 7/3/6 Event Date d - 9/// Phenol Copper Cyanide Residual Chlorine Total Dissolved Solids (TDS) Zinc City of Lincoln 5 Results (Copper and Phenol) CDM Event - 7th Street CDM Event - 7th Street NDEQ Water Quality Standard

3 Deadmans Run Watershed Water Quality Testing Results at 33rd Street Event Date d - 7/3/6 Event Date d - 9/// Phenol Copper Cyanide Residual Chlorine Total Dissolved Solids (TDS) Zinc City of Lincoln 5 Results (Copper and Phenol) CDM Event 33 rd Street CDM Event 33 rd Street NDEQ Water Quality Standard

4 7, Deadmans Run Watershed Water Quality Testing Results at 7th Street Event Date d - 7/3/6 Event Date d - 9///6 6, Concentration (cfu/ ml) 5, 4, 3,,, Fecal Coliform CDM Event - 7th Street CDM Event - 7th Street NDEQ Water Quality Standard Note: UNL recorded two Fecal Coliform values during July and July 5, 4, at 48 th Street. The values were 98,667 cfu/ml and 8,333 cfu/ml, respectively.

5 7, Deadmans Run Watershed Water Quality Testing Results at 33rd Street Event Date d - 7/3/6 Event Date d - 9///6 6, Concentration (cfu/ ml) 5, 4, 3,,, Fecal Coliform CDM Event - 33rd Street CDM Event - 33rd Street NDEQ Water Quality Standard

6 Ref. Lab #: 5388 Report Number 6--9 Mail to: 36 B Street Omaha, Nebraska (4) FAX ( CDM PATRICE MELANCON 357-A RIATA TRACE PKWY # AUSTIN TX For: (9493) CDM (5)346- Date Reported: 7//6 Date Received: 7/4/6 STORMWATER EVENT Date d: 7/3/6 Lab number: 9 ID: 67#-8 Biochemical oxygen demand 4 mg/l SM 5B cch-7/4 jjd-7/ Copper (total). mg/l. EPA.7 emr-7/8 bab-7/8 Cyanide n.d. mg/l. SM 45 CN-E jlc-7/8 jjd-7/ Fecal coliform 55, cfu/ml SM 9D arj-7/6 arj-7/6 Fecal streptococcus > cfu/ml SM 93C arj-7/6 arj-7/6 Hexane extractable materials n.d. mg/l 5 EPA 664A-SPE hbm-7/ jjd-7/ Kjeldahl nitrogen 3. mg/l.5 EPA 35.3 mjb-7/8 jjd-7/8 Lead (total) n.d. mg/l.5 EPA.7 emr-7/8 bab-7/8 Phenols n.d. mg/l.5 EPA 4. jlc-7/9 jjd-7/ Phenols n.d. mg/l.5 EPA 4. jlc-7/9 jjd-7/ Phosphorus (total).4 mg/l. EPA.7 emr-7/8 bab-7/8 Residual chlorine (ug/l) n.d. μg/l 5 SM 45-CLF cmw-7/4 dco-7/4 Total dissolved solids 3 mg/l SM 54C mfo-7/7 jjd-7/ Total suspended solids 46 mg/l 4 USGS I /SM54D mfo-7/8 jjd-7/ Zinc (total). mg/l. EPA.7 emr-7/8 bab-7/8 Notes: n.d. -. The solid analyses have been weighed to a constant weight by leaving the samples in the oven overnight. This protocol is an approved variation from the stated method. Respectfully Submitted Heather Ramig/Sue Ann Seitz/Rob Ferris Client Services

7 Ref. Lab #: 54 Report Number 6--6 Mail to: 36 B Street Omaha, Nebraska (4) FAX ( CDM PATRICE MELANCON 357-A RIATA TRACE PKWY # AUSTIN TX For: (9493) CDM (5)346- Date Reported: 7//6 Date Received: 7/4/6 XTRA BOTTLES Date d: 7/3/6 Lab number: 93 ID: 67#9 Phenols n.d. mg/l.5 EPA 4. jlc-7/9 jjd-7/ ID: 67#9 Copper (total). mg/l. EPA.7 emr-7/8 bab-7/8 Lead (total) n.d. mg/l.5 EPA.7 emr-7/8 bab-7/8 Zinc (total).7 mg/l. EPA.7 emr-7/8 bab-7/8 Notes: n.d. -. Respectfully Submitted Heather Ramig/Sue Ann Seitz/Rob Ferris Client Services

8 Ref. Lab #: 5388 Report Number 6--7 Mail to: 36 B Street Omaha, Nebraska (4) FAX ( CDM PATRICE MELANCON 357-A RIATA TRACE PKWY # AUSTIN TX For: (9493) CDM (5)346- Date Reported: 7//6 Date Received: 7/4/6 STORMWATER EVENT Date d: 7/3/6 Lab number: 9 ID: 67#-8 Biochemical oxygen demand 4 mg/l SM 5B cch-7/4 jjd-7/ Copper (total). mg/l. EPA.7 emr-7/8 bab-7/8 Cyanide n.d. mg/l. SM 45 CN-E jlc-7/8 jjd-7/ Fecal coliform 6, cfu/ml SM 9D arj-7/6 arj-7/6 Fecal streptococcus > cfu/ml SM 93C arj-7/6 arj-7/6 Hexane extractable materials n.d. mg/l 5 EPA 664A-SPE hbm-7/ jjd-7/ Kjeldahl nitrogen 4.7 mg/l.5 EPA 35.3 mjb-7/8 jjd-7/8 Lead (total) n.d. mg/l.5 EPA.7 emr-7/8 bab-7/8 Phenols n.d. mg/l.5 EPA 4. jlc-7/9 jjd-7/ Phosphorus (total).5 mg/l. EPA.7 emr-7/8 bab-7/8 Residual chlorine (ug/l) n.d. μg/l 5 SM 45-CLF cmw-7/4 dco-7/4 Total dissolved solids 334 mg/l SM 54C mfo-7/7 jjd-7/ Total suspended solids 3 mg/l 4 USGS I /SM54D mfo-7/8 jjd-7/ Zinc (total). mg/l. EPA.7 emr-7/8 bab-7/8 Notes: n.d. -. The solid analyses have been weighed to a constant weight by leaving the samples in the oven overnight. This protocol is an approved variation from the stated method. Respectfully Submitted Heather Ramig/Sue Ann Seitz/Rob Ferris Client Services

9 Ref. Lab #: 54 Report Number 6-7- Mail to: 36 B Street Omaha, Nebraska (4) FAX ( CDM PATRICE MELANCON 357-A RIATA TRACE PKWY # AUSTIN TX For: (9493) CDM (5)346- Date Reported: 9/7/6 Date Received: 9//6 XTRA BOTTLES Lab number: 346 ID: Copper (total) n.d. mg/l. EPA.7 emr-9/5 bab-9/7 Lead (total) n.d. mg/l.5 EPA.7 emr-9/5 bab-9/7 Phenols n.d. mg/l.5 EPA 4. jlc-9/7 cmw-9/7 Zinc (total).5 mg/l. EPA.7 emr-9/5 bab-9/7 Notes: n.d. -. Respectfully Submitted Heather Ramig/Sue Ann Seitz/Rob Ferris Client Services

10 Ref. Lab #: 5388 Report Number Mail to: 36 B Street Omaha, Nebraska (4) FAX ( CDM PATRICE MELANCON 357-A RIATA TRACE PKWY # AUSTIN TX For: (9493) CDM (5)346- Date Reported: //6 Date Received: 9//6 STORMWATER EVENT Lab number: 3463 ID: SITE Biochemical oxygen demand 33 mg/l SM 5B aaa-9/ cmw-/ Copper (total) n.d. mg/l. EPA.7 emr-9/5 bab-9/7 Cyanide n.d. mg/l. SM 45 CN-E jlc-9/6 cmw-/ Dissolved phosphorous.7 mg/l.5 SM 45P F lkm-9/ cmw-/ Fecal coliform 6, cfu/ml SM 9D bjl-9/ arj-9/4 Fecal streptococcus 9, cfu/ml SM 93C bjl-9/3 arj-9/4 Hexane extractable materials n.d. mg/l 5 EPA 664A-SPE hbm-9/9 cmw-/ Kjeldahl nitrogen 5.5 mg/l.5 EPA 35.3 his-9/5 cmw-9/6 Lead (total) n.d. mg/l.5 EPA.7 emr-9/5 bab-9/7 Phenols n.d. mg/l.5 EPA 4. jlc-9/7 cmw-/ Phosphorus (total).4 mg/l. EPA.7 emr-9/5 bab-9/7 Residual chlorine (ug/l) n.d. μg/l 5 SM 45-CLF cmw-9/ abd-9/ Total dissolved solids 336 mg/l SM 54C jeg-9/8 cmw-/ Total suspended solids 47 mg/l 4 USGS I /SM54D jeg-9/8 cmw-/ Zinc (total).5 mg/l. EPA.7 emr-9/5 bab-9/7

11 36 B Street Omaha, Nebraska (4) FAX ( Account: 9493 CDM Page: Report Number: ID: SITE Biochemical oxygen demand 3 mg/l SM 5B aaa-9/ cmw-/ Copper (total) n.d. mg/l. EPA.7 emr-9/5 bab-9/7 Cyanide n.d. mg/l. SM 45 CN-E jlc-9/6 cmw-/ Dissolved phosphorous.6 mg/l.5 SM 45P F lkm-9/ cmw-/ Fecal coliform 6, cfu/ml SM 9D bjl-9/ arj-9/4 Fecal streptococcus 9, cfu/ml SM 93C bjl-9/3 arj-9/4 Hexane extractable materials n.d. mg/l 5 EPA 664A-SPE hbm-9/9 cmw-/ Kjeldahl nitrogen. mg/l.5 EPA 35.3 his-9/5 cmw-9/6 Lead (total) n.d. mg/l.5 EPA.7 emr-9/5 bab-9/7 Phenols n.d. mg/l.5 EPA 4. jlc-9/7 cmw-/ Phosphorus (total). mg/l. EPA.7 emr-9/5 bab-9/7 Residual chlorine (ug/l) n.d. μg/l 5 SM 45-CLF cmw-9/ abd-9/ Total dissolved solids 9 mg/l SM 54C jeg-9/8 cmw-/ Total suspended solids 77 mg/l 4 USGS I /SM54D jeg-9/8 cmw-/ Zinc (total). mg/l. EPA.7 emr-9/5 bab-9/7 Notes: n.d. -. The solid analyses have been weighed to a constant weight by leaving the samples in the oven overnight. This protocol is an approved variation from the stated method. Respectfully Submitted Heather Ramig/Sue Ann Seitz/Rob Ferris Client Services

Texas Commission on Environmental Quality

Texas Commission on Environmental Quality Matrix: Drinking Water Method EPA 1603 (modified mtec) AB ID Method ID Escherichia coli (enumeration) TX 2525 10236201 Method EPA 200.5 AB ID Method ID Arsenic TX 1010 10213975 Beryllium TX 1020 10213975

More information

DMR-QA Planning Guide 2015 DMR-QA 35: Plan for Success

DMR-QA Planning Guide 2015 DMR-QA 35: Plan for Success DMR-QA Planning Guide 2015 DMR-QA 35: Plan for Success [ THE INDUSTRY STANDARD ] Your Partner In Defensible Data We understand that the art of our superior service is just as important as the science of

More information

Water and Wastewater. Sample Collection and Analysis

Water and Wastewater. Sample Collection and Analysis Water and Wastewater Sample Collection and Analysis December 2011 Introduction Accurate testing of drinking water is crucial to maintaining the health and safety of Islanders who rely on this resource.

More information

NPDES Permit No. IL0022071. Notice No. AAH:10120701.ajo. Public Notice Beginning Date: April 28, 2011. Public Notice Ending Date: May 30, 2011

NPDES Permit No. IL0022071. Notice No. AAH:10120701.ajo. Public Notice Beginning Date: April 28, 2011. Public Notice Ending Date: May 30, 2011 Public Notice/Fact Sheet Issued By: Notice No. AAH:10120701.ajo Public Notice Beginning Date: April 28, 2011 Public Notice Ending Date: May 30, 2011 National Pollutant Discharge Elimination System (NPDES)

More information

CALIFORNIA DEPARTMENT OF PUBLIC HEALTH ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing

CALIFORNIA DEPARTMENT OF PUBLIC HEALTH ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing CALIFORNIA DEPARTMENT OF PUBLIC HEALTH ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing Babcock Laboratories, Inc. 6100 Quail Valley Court Riverside, CA 92507 Phone: (951) 653-3351

More information

Read all instructions carefully before completing the application. Applications must be typewritten.

Read all instructions carefully before completing the application. Applications must be typewritten. Appendix A Tier 2 Application A This application is designed for use by laboratories seeking accreditation for samples analyzed for compliance with a National Pollution Discharge Elimination System (NPDES)

More information

Case Study of an Advanced On-Site Wastewater Treatment System Connected to a Single-Family Residence

Case Study of an Advanced On-Site Wastewater Treatment System Connected to a Single-Family Residence Case Study of an Advanced On-Site Wastewater Treatment System Connected to a Single-Family Residence Christina M. Edvardsson and David R. Spears, MicroSepTec, Inc., 2661 Cabot Road, Laguna Hills, CA 92653

More information

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures. Page 16 of 87 3.3 Sample Collection, Storage and Preservation Figure 3 details required containers, sample volumes, preservation techniques, and holding times for proper sample collection. A discussion

More information

User s Guide for the Discharge Monitoring Report (DMR) Pollutant Loading Tool. EZ Search, Facility Search, and Advanced Search. Version 1.

User s Guide for the Discharge Monitoring Report (DMR) Pollutant Loading Tool. EZ Search, Facility Search, and Advanced Search. Version 1. User s Guide for the Discharge Monitoring Report (DMR) Pollutant Loading Tool EZ Search, Facility Search, and Advanced Search Version 1.0 January 2012 Table of Contents TABLE OF CONTENTS Page 1. OVERVIEW...

More information

Microbiological Testing of the Sawyer Mini Filter. 16 December 2013. Summary

Microbiological Testing of the Sawyer Mini Filter. 16 December 2013. Summary Microbiological Testing of the Sawyer Mini Filter 16 December 2013 Summary The Sawyer Mini Filter was tested for its ability to remove three microorganisms Raoultella terrigena, Bacillus subtilis, and

More information

STORMWATER MONITORING: POLLUTANTS, SOURCES, AND SOLUTIONS

STORMWATER MONITORING: POLLUTANTS, SOURCES, AND SOLUTIONS RICHLAND COUNTY STORMWATER MANAGEMENT DIVISION STORMWATER MONITORING: POLLUTANTS, SOURCES, AND SOLUTIONS As part of the federal government s National Pollutant Discharge Elimination System Permit (NPDES)

More information

The purpose of this bid is to procure a contract with a laboratory to provide analytical testing services on an as-needed basis.

The purpose of this bid is to procure a contract with a laboratory to provide analytical testing services on an as-needed basis. Page 1 of 11 1. GENERAL The purpose of this bid is to procure a contract with a laboratory to provide analytical testing services on an as-needed basis. Special consideration may be given to laboratories

More information

TERRA TEK LIMITED GUIDE TO SAMPLE HANDLING. Version 1.06

TERRA TEK LIMITED GUIDE TO SAMPLE HANDLING. Version 1.06 TERRA TEK LIMITED GUIDE TO SAMPLE HANDLING Version 1.06 September 2009 Guidance on Sample Containers & Storage Conditions - SOIL SAMPLES 500ml Plastic Tub Suitable for: Inorganic Parameters, usually sufficient

More information

DRAFT Changes to 25 Pa. Code Chapter 252 For Discussion Purposes Only January 21, 2015 CHAPTER 252. ENVIRONMENTAL LABORATORY ACCREDITATION

DRAFT Changes to 25 Pa. Code Chapter 252 For Discussion Purposes Only January 21, 2015 CHAPTER 252. ENVIRONMENTAL LABORATORY ACCREDITATION CHAPTER 252. ENVIRONMENTAL LABORATORY ACCREDITATION Subchapter A. GENERAL PROVISIONS B. APPLICATION, FEES AND SUPPORTING DOCUMENTS C. GENERAL STANDARDS FOR ACCREDITATION D. QUALITY ASSURANCE AND QUALITY

More information

Suspended Solids: Unequal Results from Equal Methods

Suspended Solids: Unequal Results from Equal Methods Suspended Solids: Unequal Results from Equal Methods By John Stone As of November 2003, 40 CFR, Part 136 lists five approved methods for determining Total Suspended Solids (Residue). Major differences

More information

Fixing Bacterial Quality

Fixing Bacterial Quality Environment Your Well Water Fixing Bacterial Quality 2 This booklet series describes what private well owners can do to maintain clean, safe drinking water from their well to protect their health. This

More information

Report No. 446 CITY OF DURHAM WATER QUALITY WEB PORTAL. By Xiaoyan Qi and Jennifer Dorton

Report No. 446 CITY OF DURHAM WATER QUALITY WEB PORTAL. By Xiaoyan Qi and Jennifer Dorton Report No. 446 CITY OF DURHAM WATER QUALITY WEB PORTAL By Xiaoyan Qi and Jennifer Dorton Center for Marine Science University of North Carolina at Wilmington Wilmington, NC UNC-WRRI-446 The research on

More information

To meet our acceptance criteria, we may require you to partially treat your wastewater before it discharges to sewer.

To meet our acceptance criteria, we may require you to partially treat your wastewater before it discharges to sewer. Trade Waste Acceptance criteria for trade waste Information sheet 6 Acceptance criteria for industrial waste Water Corporation s wastewater system is designed primarily to service households with normal

More information

Total Suspended Solids: The Hows & Whys of Controlling Runoff Pollution

Total Suspended Solids: The Hows & Whys of Controlling Runoff Pollution New State Storm Water Rules: WHAT MUNICIPALITIES NEED TO KNOW Total Suspended Solids: The Hows & Whys of Controlling Runoff Pollution Stormwater management by Wisconsin municipalities is under scrutiny.

More information

2014 Report. water Quality. Cleveland Water

2014 Report. water Quality. Cleveland Water 2014 Report water Quality Cleveland Water Commitment to Quality Cleveland Water is committed to providing all of our customers with a virtually unlimited supply of clean, safe, potable water. This commitment

More information

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE 06/15/12

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE 06/15/12 1 of 5 Since ELAP no longer certifies for the CLP tier, the CLP tier personnel requirements were removed from this item. Technical Director Each environmental laboratory shall appoint one or more technical

More information

Comparing Levels of Phosphates in Dishwasher Detergents

Comparing Levels of Phosphates in Dishwasher Detergents Lesson Plan Grades 9-12 Note: The Student Resource Page and Student Worksheets can be found at the end of this lesson plan. Essential Questions > How can phosphate levels in water be measured? > How much

More information

Prepared for City of Vancouver Surface Water Management

Prepared for City of Vancouver Surface Water Management 2014 MONITORING REPORT BURNT BRIDGE CREEK AMBIENT WATER QUALITY MONITORING PROGRAM Prepared for City of Vancouver Surface Water Management Prepared by Herrera Environmental Consultants, Inc. 2014 MONITORING

More information

Requirements for the ongoing assessment of treatment system performance

Requirements for the ongoing assessment of treatment system performance Requirements for the ongoing assessment of treatment system performance Procedural guidelines for owners and masters of ships fitted with sewage treatment systems Contents 1 Overview... 4 1.1 Stages of

More information

Determination of a Chemical Formula

Determination of a Chemical Formula 1 Determination of a Chemical Formula Introduction Molar Ratios Elements combine in fixed ratios to form compounds. For example, consider the compound TiCl 4 (titanium chloride). Each molecule of TiCl

More information

Mystic River Watershed Association Water Quality Monitoring: Malden River May 28 th 2002

Mystic River Watershed Association Water Quality Monitoring: Malden River May 28 th 2002 Mystic River Watershed Association Water Quality Monitoring: Malden River May 28 th 2002 Introduction The Mystic River Watershed Association, through its Mystic Monitoring Network (MMN) program, has been

More information

1 Quality Assurance and Quality Control Project Plan

1 Quality Assurance and Quality Control Project Plan 1 Quality Assurance and Quality Control Project Plan The purpose of this section is to describe the quality assurance/quality control program that will be used during the system specific field testing

More information

Statistical Analyses and Summary of Analytical Round Robin #5 a Data Comparability Study Report prepared by Raymond E. Leary December 2012

Statistical Analyses and Summary of Analytical Round Robin #5 a Data Comparability Study Report prepared by Raymond E. Leary December 2012 Statistical Analyses and Summary of Analytical Round Robin #5 a Data Comparability Study Report prepared by Raymond E. Leary December 2012 Samples collected October 18, 2010 from the Florida State University

More information

Nitrogen, Phosphorus, and Suspended Solids Concentrations in Tributaries to the Great Bay Estuary Watershed in 2011

Nitrogen, Phosphorus, and Suspended Solids Concentrations in Tributaries to the Great Bay Estuary Watershed in 2011 Nitrogen, Phosphorus, and Suspended Solids Concentrations in Tributaries to the Great Bay Estuary Watershed in 2011 A Final Report to The Piscataqua Region Estuaries Partnership Submitted by Matthew A.

More information

Development and Implementation of a Water Quality Monitoring Plan to Support. the Creation of a Geographic Information System to Assess Water Quality

Development and Implementation of a Water Quality Monitoring Plan to Support. the Creation of a Geographic Information System to Assess Water Quality Development and Implementation of a Water Quality Monitoring Plan to Support the Creation of a Geographic Information System to Assess Water Quality Conditions of Rivers in the State of Veracruz in Mexico

More information

Report for 2002NE12B: Assessment of Source of Variation in Copper Concentrations in Nebraska Drinking Water Systems

Report for 2002NE12B: Assessment of Source of Variation in Copper Concentrations in Nebraska Drinking Water Systems Report for 2002NE12B: Assessment of Source of Variation in Copper Concentrations in Nebraska Drinking Water Systems There are no reported publications resulting from this project. Title: Assessment of

More information

Stormwater Quality Monitoring Report

Stormwater Quality Monitoring Report Stormwater Quality Monitoring Report Permeable Interlocking Concrete Pavement (PICP) at Denver Wastewater Management Building Denver, Colorado 28-21 October 211 Prepared by Holly Piza, P.E., and Claire

More information

Title 22: HEALTH AND WELFARE

Title 22: HEALTH AND WELFARE Title 22: HEALTH AND WELFARE Chapter 157-A: HEALTH AND ENVIRONMENTAL TESTING LABORATORY HEADING: PL 1991, c. 499, 2 (new) Table of Contents Subtitle 2. HEALTH... Part 2. STATE AND LOCAL HEALTH AGENCIES...

More information

Laboratory analysis for wastewater treatment, industrial monitoring, and environmental protection

Laboratory analysis for wastewater treatment, industrial monitoring, and environmental protection Laboratory analysis for wastewater treatment, industrial monitoring, and environmental protection The man who started it all Dr. W.D. Hatfield was an innovator in wastewater treatment technologies and

More information

Determinants of Bacterial Contamination in Pools, Spas, and Wading Pools: Should Chlorine Standards Be Revised?

Determinants of Bacterial Contamination in Pools, Spas, and Wading Pools: Should Chlorine Standards Be Revised? International Journal of Aquatic Research and Education, 2010, 4, 33-38 2010 Human Kinetics, Inc. Determinants of Bacterial Contamination in Pools, Spas, and Wading Pools: Should Chlorine Standards Be

More information

Measurement by Ion Selective Electrodes

Measurement by Ion Selective Electrodes Measurement by Ion Selective Electrodes Adrian Vazquez May 8, 2012 Why Use Ion Selective Electrodes? Responsive over a wide concentration range Not affected by color or turbidity of sample Rugged and durable

More information

RESIDENTIAL TREATMENT SYSTEMS

RESIDENTIAL TREATMENT SYSTEMS EFFLUENT SAMPLING FOR RESIDENTIAL TREATMENT SYSTEMS For various reasons, many wastewater treatment systems periodically require effluent sampling and characterization. Whether sampling is done to verify

More information

THE NEW NSF 350 AND 350-1

THE NEW NSF 350 AND 350-1 THE NEW NSF 350 AND 350-1 These American National Standards help in evaluating and approving water reuse treatment technologies. BY TOM BRUURSEMA Figure 1 At the NSF residential wastewater treatment system

More information

Surface water remediation and waste water treatment using circulators

Surface water remediation and waste water treatment using circulators RemTech 2006 Surface water remediation and waste water treatment using circulators Produced by: Kathleen Cameron (M.Sc. PAg) - Manager Created by: Catherine Cameron Artistic Director Sunset Solar Systems

More information

Page 1 of 10 PART II TABLE OF CONTENTS GENERAL REQUIREMENTS (a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r) (s) (t) (u) (v) (w) (x) (y) Duty to Comply Duty to Reapply Need to Halt

More information

Introduction. The following definitions may help you better understand the components of the data report.

Introduction. The following definitions may help you better understand the components of the data report. Introduction This document is designed to help our clients understand the quality control requirements and limitations of data reporting. There are three sections to this document. The first section will

More information

ENGINEERING REPORT Sewage Treatment System

ENGINEERING REPORT Sewage Treatment System CIVIL & STRUCTURAL ENGINEERING CONSULTANTS 7A Barbados Avenue, Kingston 5, Jamaica, Tele: (876) 754-2154/5 Fax: (876) 754-2156 E-mail: mail@fcsconsultants.com GORE FLORENCE HALL DEVELOPMENT FCS # 0827/76/C

More information

Analysis of the Water Quality of Eighteenmile Creek, Erie County, New York:

Analysis of the Water Quality of Eighteenmile Creek, Erie County, New York: Analysis of the Water Quality of Eighteenmile Creek, Erie County, New York: A Comparison of Water Quality Between 1970, 1973 and 2000 By: Kristal Lynn Krasinski Senior Student Department of Geography/Planning

More information

Consolidation of Bylaw No. 536-2003 SEWERS BYLAW

Consolidation of Bylaw No. 536-2003 SEWERS BYLAW Date of Consolidation: March 10, 2009 Consolidation of Adopted January 27, 2003 As Amended By: Bylaw No. 590-2005 adopted January 24, 2005 Bylaw No. 641-2006 adopted May 23, 2006 Bylaw No. 666-2007 adopted

More information

MUNICIPAL NPDES PERMIT. issued to. Facility ID: 095-001 Permit ID: CT0100382 Permit Expires: September 20, 2011

MUNICIPAL NPDES PERMIT. issued to. Facility ID: 095-001 Permit ID: CT0100382 Permit Expires: September 20, 2011 MUNICIPAL NPDES PERMIT issued to Permittee: Location Address City of New London Water Pollution Control Facility 181 State Street 100 Trumbull Street New London, Connecticut 06320 New London, Connecticut

More information

Algal Blooms, Circulators, Waterfowl and Eutrophic Greenfield Lake, NC. Michael A. Mallin, Matthew R. McIver, Ellen J. Wambach, and Anna R.

Algal Blooms, Circulators, Waterfowl and Eutrophic Greenfield Lake, NC. Michael A. Mallin, Matthew R. McIver, Ellen J. Wambach, and Anna R. Algal Blooms, Circulators, Waterfowl and Eutrophic Greenfield Lake, NC Michael A. Mallin, Matthew R. McIver, Ellen J. Wambach, and Anna R. Robuck Center for Marine Science University of North Carolina

More information

Brewery Wastewater: 2010 Water and Wastewater Conference. 11.02.2011 Page 1

Brewery Wastewater: 2010 Water and Wastewater Conference. 11.02.2011 Page 1 Brewery Wastewater: Solutions for the Problem By Fred M. Scheer 2010 Water and Wastewater Conference Madison, WI 11.02.2011 Page 1 vr74 What We Will Discuss: Biochemical i Oxygen Demand (BOD): Where does

More information

NPDES Permit No. IL0052639. Notice No. IL0052639-12.TTL. Public Notice Beginning Date: June 15, 2012. Public Notice Ending Date: July 16, 2012

NPDES Permit No. IL0052639. Notice No. IL0052639-12.TTL. Public Notice Beginning Date: June 15, 2012. Public Notice Ending Date: July 16, 2012 NPDES Permit No. IL0052639 Notice No. IL0052639-12.TTL Public Notice/Fact Sheet Issued By: Public Notice Beginning Date: June 15, 2012 Public Notice Ending Date: July 16, 2012 National Pollutant Discharge

More information

COMMUNITY ENVIRONMENTAL SERVICES, INC.

COMMUNITY ENVIRONMENTAL SERVICES, INC. COMMUNITY ENVIRONMENTAL SERVICES, INC. 2101 South IH-35, Suite 400 Austin, TX 78741 Ph: (800) 654-3342 FAX: (512) 444-2313 www.ces-txvi.com Community Environmental Services, Inc. (CES) is a small civil-environmental

More information

Industrial Storm Water Best Management Practices. Restoring, maintaining, and enhancing the quality of Oregon's water.

Industrial Storm Water Best Management Practices. Restoring, maintaining, and enhancing the quality of Oregon's water. Industrial Storm Water Best Management Practices Restoring, maintaining, and enhancing the quality of Oregon's water. Catch Basin Sampling Device For use on catch basins which have discharge from more

More information

Overview of Best Available Technologies for Onsite Septic Systems and Management Considerations Presentation to NAHB

Overview of Best Available Technologies for Onsite Septic Systems and Management Considerations Presentation to NAHB Overview of Best Available Technologies for Onsite Septic Systems and Management Considerations Presentation to NAHB A. R. Rubin, Professor Emeritus, NCSU-BAE Technical Wastewater Issues Treatment Septic

More information

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL 1 of 8 The quality assurance plan as presented in the Quality Manual should assure that constant and consistent test conditions are met and verified and should be tailored to the laboratory s activities.

More information

NPDES Permit No. IL0020737. Notice No. SKT:13120601.bah. Public Notice Beginning Date: April 9, 2014. Public Notice Ending Date: May 9, 2014

NPDES Permit No. IL0020737. Notice No. SKT:13120601.bah. Public Notice Beginning Date: April 9, 2014. Public Notice Ending Date: May 9, 2014 Public Notice/Fact Sheet Issued By: Notice No. SKT:13120601.bah Public Notice Beginning Date: April 9, 2014 Public Notice Ending Date: May 9, 2014 National Pollutant Discharge Elimination System (NPDES)

More information

Water Quality For Poultry

Water Quality For Poultry Water Quality For Poultry Amy E. Halls, M.Sc. Monogastric Nutritionist Shur-Gain, Nutreco Canada Inc. January 2008 Water Quality For Poultry Amy E. Halls, M.Sc. Monogastric Nutritionist Shur-Gain, Nutreco

More information

ATTACHMENT 2. BMP Monitoring Plan Template

ATTACHMENT 2. BMP Monitoring Plan Template ATTACHMENT 2 BMP Monitoring Plan Template Project SPR - 335 Water Quality Facility Investigation Response to Modified Task 4: Development of BMP Monitoring Plan Template December 2002 i Table of Contents

More information

Continuous-Flow Analyzers

Continuous-Flow Analyzers _ Continuous-Flow Analyzers _ Rapid Control of Fertilizer Quality with the AutoAnalyzer Legislation and quality requirements have led to the need for close control of fermentation and finished products

More information

This example of a completed sampling plan worksheet has been included to illustrate the information

This example of a completed sampling plan worksheet has been included to illustrate the information APPENDIX B EXAMPLE OF A COMPLETED SAMPLING PLAN WORKSHEET This example of a completed sampling plan worksheet has been included to illustrate the information necessary to document a sampling program for

More information

Guide to Writing a Water Quality Monitoring Plan

Guide to Writing a Water Quality Monitoring Plan Guide to Writing a Water Quality Monitoring Plan 2013 Scoping Worksheets and Plan Template This guide has been compiled by the Community-Based Environmental Monitoring Network and CURA H2O to assist stewardship

More information

City of East Lansing CSO Control Facility Evaluation Demonstrative Approach to Meet WQS

City of East Lansing CSO Control Facility Evaluation Demonstrative Approach to Meet WQS City of East Lansing CSO Control Facility Evaluation Demonstrative Approach to Meet WQS Jeff Johnston, East Lansing WWTP Superintendent & Tom Maxwell, P.E., Hubbell, Roth & Clark, Inc. East Lansing CSO

More information

PERMITTEE/FACILITY NAME: City of Detroit Water and Sewerage Department / Detroit Wastewater Treatment Plant

PERMITTEE/FACILITY NAME: City of Detroit Water and Sewerage Department / Detroit Wastewater Treatment Plant Permit No. MI0022802 FACT SHEET PERMITTEE/FACILITY NAME: City of Detroit / Detroit Wastewater Treatment Plant COUNTY: Wayne DESCRIPTION OF EXISTING WASTEWATER TREATMENT FACILITIES: The Detroit (DWSD) owns

More information

THE CORPORATION OF THE CITY OF MISSISSAUGA STORM SEWER BY-LAW 259-05. ( amended by 356-10)

THE CORPORATION OF THE CITY OF MISSISSAUGA STORM SEWER BY-LAW 259-05. ( amended by 356-10) ( amended by 356-10) WHEREAS the Municipal Act 2001, R.S.O. 2001, S.O. 2001, c. 25, as amended authorizes the City to regulate with respect to storm sewers and drainage from land; AND WHEREAS it is necessary

More information

ENVIRONMENTAL ISSUES IN THE RENDERING INDUSTRY. Gregory L. Sindt, P.E. Environmental Engineer Bolton and Menk, Inc.

ENVIRONMENTAL ISSUES IN THE RENDERING INDUSTRY. Gregory L. Sindt, P.E. Environmental Engineer Bolton and Menk, Inc. Summary ENVIRONMENTAL ISSUES IN THE RENDERING INDUSTRY Gregory L. Sindt, P.E. Environmental Engineer Bolton and Menk, Inc. The rendering industry has a significant positive impact on environmental quality.

More information

LIMNOLOGY, WATER QUALITY

LIMNOLOGY, WATER QUALITY LIMNOLOGY, WATER QUALITY PA RANI ET E R S, AN D c 0 IV D IT I 0 N S AND ECOREGIONS Water Quality Parameters Nutrients are important parameters because phosphorous and nitrogen are major nutrients required

More information

Canada-wide Strategy for the Management of Municipal Wastewater Effluent

Canada-wide Strategy for the Management of Municipal Wastewater Effluent Canada-wide Strategy for the Management of Municipal Wastewater Effluent Endorsed by CCME Council of Ministers, February 17, 2009, Whitehorse Executive Summary Wastewater from households, industrial, commercial

More information

-O^ DEQ. National Pollutant Discharge Elimination System PERMIT EVALUATION AND FACT SHEET November 12,2003

-O^ DEQ. National Pollutant Discharge Elimination System PERMIT EVALUATION AND FACT SHEET November 12,2003 \ I -O^ DEQ State of Oregon Department of Environmental Quality National Pollutant Discharge Elimination System PERMIT EVALUATION AND FACT SHEET November 12,2003 Oregon Department of Environmental Quality

More information

Standard methods in water analysis

Standard methods in water analysis Branch General analytical laboratories; water analysis Keywords Water analysis; standard methods; ASTM; DIN; ISO; USP; EPA; SLMB; EN; SCA; titration; ion chromatography; voltammetry; branch 1; branch 2

More information

NOTICES DEPARTMENT OF BANKING AND SECURITIES DEPARTMENT OF CONSERVATION AND NATURAL RESOURCES

NOTICES DEPARTMENT OF BANKING AND SECURITIES DEPARTMENT OF CONSERVATION AND NATURAL RESOURCES 330 DEPARTMENT OF BANKING AND SECURITIES Maximum Lawful Rate of Interest for Residential Mortgages for the Month of February 2014 The Department of Banking and Securities (Department), under the authority

More information

ANALYTICAL SUMMARY REPORT

ANALYTICAL SUMMARY REPORT ANALYTICAL SUMMARY REPORT OST-003 August 06, 2015 PO Box 2003 Rapid City, SD 57709 Work Order: Project Name: G15070702 Energy Laboratories Inc. Gillette WY received the following 2 samples for on 7/31/2015

More information

Local Initiatives in Water Quality Management Programs in the Philippines: Policy Issues and Challenges

Local Initiatives in Water Quality Management Programs in the Philippines: Policy Issues and Challenges Local Initiatives in Water Quality Management Programs in the Philippines: Policy Issues and Challenges Carlos M. Pascual*, Catherine P. Abadilla, and Fairie Anne P. Acedebo Mariano Marcos State University

More information

CITY OF BAD AXE 2014 WATER QUALITY REPORT

CITY OF BAD AXE 2014 WATER QUALITY REPORT CITY OF BAD AXE 2014 WATER QUALITY REPORT In 1996, Congress amended the Safe Drinking Water Act which added a provision requiring that all community water systems provide their customers a brief annual

More information

City of Monroe Wastewater System Report

City of Monroe Wastewater System Report 2013 City of Monroe Wastewater System Report Protecting the environment is a top priority for the City of Monroe Water Resources Department. We are pleased to present our annual Wastewater System Report.

More information

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES 4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES Sl. No. Contents Preamble 4.1 Aim 4.2 Introduction 4.2.1 Environmental Significance 4.3 Principle 4.4 Materials Required 4.4.1 Apparatus Required 4.4.2 Chemicals

More information

Determination of the Mass Percentage of Copper in a Penny. Introduction

Determination of the Mass Percentage of Copper in a Penny. Introduction Determination of the Mass Percentage of Copper in a Penny Introduction This experiment will cost you one penny ($0.01). The penny must be minted after 1983. Any penny will do; for best results the penny

More information

The Technology Acceptance Reciprocity Partnership. Protocol for. Stormwater Best Management Practice Demonstrations

The Technology Acceptance Reciprocity Partnership. Protocol for. Stormwater Best Management Practice Demonstrations The Technology Acceptance Reciprocity Partnership Protocol for Stormwater Best Management Practice Demonstrations Endorsed by California, Massachusetts, Maryland, New Jersey, Pennsylvania, and Virginia

More information

ADDENDUM TO THE FACT SHEET FOR NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT NO. WA-002264-1 June 25, 2010

ADDENDUM TO THE FACT SHEET FOR NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT NO. WA-002264-1 June 25, 2010 ADDENDUM TO THE FACT SHEET FOR NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT NO. WA-002264-1 June 25, 2010 I. GENERAL INFORMATION Facility: City of Blaine Wastewater Treatment Plants 9235

More information

The marine environment of the Southern California

The marine environment of the Southern California Characteristics of effluents from large municipal wastewater treatment facilities in 1997 Valerie E. Raco-Rands and Andrea Steinberger ABSTRACT The marine environment of the Southern California Bight (SCB)

More information

EPA New England Regional Laboratory. EPA Project Team: Liz McCarthy. Matt Destino Tim Bridges Dick Siscanaw

EPA New England Regional Laboratory. EPA Project Team: Liz McCarthy. Matt Destino Tim Bridges Dick Siscanaw EPA s River Real Time Monitoring Buoy in the Charles and Mystic Watersheds Access to the data has been through a password protected site http://www.ysieconet.com/ Tom Faber EPA New England Regional Laboratory

More information

Unit 1. Physical, chemical and biological Characteristics of Wastewater

Unit 1. Physical, chemical and biological Characteristics of Wastewater The Islamic University of Gaza- Civil Engineering Department Advanced Sanitary Engineering- ECIV 5325 Unit 1. Physical, chemical and biological Characteristics of Wastewater Based on Dr. Fahid Rabah lecture

More information

CHAPTER 5 - WASTEWATER TREATMENT FACILITIES

CHAPTER 5 - WASTEWATER TREATMENT FACILITIES CHAPTER 5 - WASTEWATER TREATMENT FACILITIES 5.1 Introduction The purpose of this chapter is to summarize the evaluation of the existing wastewater facilities infrastructure and performance. The results

More information

Maine Department of Environmental Protection Program Guidance On Combined Sewer Overflow Facility Plans

Maine Department of Environmental Protection Program Guidance On Combined Sewer Overflow Facility Plans Maine Department of Environmental Protection Program Guidance On Combined Sewer Overflow Facility Plans OVERVIEW The objective of a Combined Sewer Overflow (CSO) Facility Plan is to abate CSO discharges

More information

South East of Process Main Building / 1F. North East of Process Main Building / 1F. At 14:05 April 16, 2011. Sample not collected

South East of Process Main Building / 1F. North East of Process Main Building / 1F. At 14:05 April 16, 2011. Sample not collected At 14:05 April 16, 2011 At 13:55 April 16, 2011 At 14:20 April 16, 2011 ND ND 3.6E-01 ND ND 3.6E-01 1.3E-01 9.1E-02 5.0E-01 ND 3.7E-02 4.5E-01 ND ND 2.2E-02 ND 3.3E-02 4.5E-01 At 11:37 April 17, 2011 At

More information

MOLES AND MOLE CALCULATIONS

MOLES AND MOLE CALCULATIONS 35 MOLES ND MOLE CLCULTIONS INTRODUCTION The purpose of this section is to present some methods for calculating both how much of each reactant is used in a chemical reaction, and how much of each product

More information

Removing Heavy Metals from Wastewater

Removing Heavy Metals from Wastewater Removing Heavy Metals from Wastewater Engineering Research Center Report David M. Ayres Allen P. Davis Paul M. Gietka August 1994 1 2 Removing Heavy Metals From Wastewater Introduction This manual provides

More information

Saudi Aramco Project Development

Saudi Aramco Project Development Saudi Aramco Project Development Wastewater Treatment Facilities Jeddah Refinery And Marine Area December 2007 Facilities Planning Dept. OBJECTIVE: Provide an overview of the complexities of developing

More information

Notification Requirements for CMSA NPDES Permit Exceedances and Collection System Sanitary Sewer Overflows Date: April 2, 2008 (Revised July 10, 2012)

Notification Requirements for CMSA NPDES Permit Exceedances and Collection System Sanitary Sewer Overflows Date: April 2, 2008 (Revised July 10, 2012) Requirements for CMSA NPDES Permit Exceedances and Collection System Sanitary Sewer Overflows Date: April 2, 2008 (Revised July 10, 2012) 1. Purpose To outline the Agency s notification and reporting requirements

More information

Electronic Reporting to BTS

Electronic Reporting to BTS Electronic Reporting to BTS EPA s Electronic Reporting Tool (ERT) Software to Standardize Source Test Planning, Reporting and Assessment. http://www.epa.gov/ttnchie1/ert/ Enhancements made to improve and

More information

LED Life-Cycle Assessment & Environmental Testing

LED Life-Cycle Assessment & Environmental Testing LED Life-Cycle Assessment & Environmental Testing DOE Solid State Lighting Booth Presentation LightFair 2013 Jason Tuenge Pacific Northwest National Laboratory Program Name or Ancillary Text eere.energy.gov

More information

Importante: Si usted tiene alguna pregunta sobre este informe favor de llamar a Lee County Utilities al 239-533-8181.

Importante: Si usted tiene alguna pregunta sobre este informe favor de llamar a Lee County Utilities al 239-533-8181. Lee County Utilities 2015 Water Quality Report Importante: Si usted tiene alguna pregunta sobre este informe favor de llamar a Lee County Utilities al 239-533-8181. Introduction Lee County Utilities (LCU)

More information

Application for Controlled Trade Waste Discharge Approval

Application for Controlled Trade Waste Discharge Approval HDC Standard Application form Date issued: 1/12/2014 Application for Controlled Trade Waste Discharge Approval (Please print clearly) The Applicant Name of discharger:... Address of Premises: Postal address

More information

Cambridge Wastewater Treatment Facility

Cambridge Wastewater Treatment Facility Cambridge Wastewater Treatment Facility Emergency Situations If you have a water or sewer emergency that relates to the City s utility system call the Public Works office at 763-689-1800 on normal working

More information

2010 Annual Drinking Water Quality Report Collier County Water Department

2010 Annual Drinking Water Quality Report Collier County Water Department Annual Drinking Water Quality Report Collier County Water Department The Collier County Water Department is pleased to present this annual water quality report. We trust that you will read this report

More information

Cudby Contracting Limited Quarry Monitoring Programme Biennial Report 2011-2013

Cudby Contracting Limited Quarry Monitoring Programme Biennial Report 2011-2013 Cudby Contracting Limited Quarry Monitoring Programme Biennial Report 2011-2013 Technical Report 2013-107 ISSN: 0114-8184 (Print) Taranaki Regional Council ISSN: 1178-1467 (On line) Private Bag 713 Document:

More information

Parts per million (ppm) or Milligrams per liter (mg/l): one part by weight of analyte to 1 million parts by weight of the water sample.

Parts per million (ppm) or Milligrams per liter (mg/l): one part by weight of analyte to 1 million parts by weight of the water sample. 2015 Annual Drinking Water Quality Report St. Johns County Utility CR 214 Mainland We're pleased to present to you this year's Annual Water Quality Report. This report is designed to inform you about the

More information

Application Form 2E. Facilities Which Do Not Discharge Process Wastewater

Application Form 2E. Facilities Which Do Not Discharge Process Wastewater United States Environmental Protection Agency Office of Water Enforcement and Permits Washington, DC 20460 EPA Form 3510-2E Revised August 1990 Permits Division Application Form 2E Facilities Which Do

More information

Real-Time Monitoring Buoy in Mystic River Watershed

Real-Time Monitoring Buoy in Mystic River Watershed Real-Time Monitoring Buoy in Mystic River Watershed Access to the data has been through a password protected site http://www.ysieconet.com/ Project Assistance: Liz McCarthy Laura Senefeld Matt Destino

More information

December 5, 2011. Dear Mr. Wilpan:

December 5, 2011. Dear Mr. Wilpan: STATE OF MAINE D EPARTMENT OF E NVIRONMENTAL P ROTECTION PAUL R. LEPAGE GOVERNOR PATRICIA W. AHO COMMISSIONER December 5, 2011 Robert Wilpan Town of Sorrento Board of Selectmen 79 Pomala Avenue Sorrento,

More information

Floating Treatment Wetland Technology: Nutrient Removal from Wastewater

Floating Treatment Wetland Technology: Nutrient Removal from Wastewater Floating Treatment Wetland Technology: Nutrient Removal from Wastewater This case study illustrates the Floating Island International (FII) patented floating treatment wetland (FTW) technology and its

More information

Aerated Wastewater T r eatment System

Aerated Wastewater T r eatment System GOVERNMENT Aerated Wastewater T r eatment System This Certificate of Accreditation is hereby issued by the Director-General of the NSW Ministry of Health pursuant to Clause 41(1) of the Local Government

More information