Princeton Gamma-Tech Instruments, Inc. 303C College Road East Princeton, NJ
|
|
- Erica Adams
- 8 years ago
- Views:
Transcription
1 Princeton Gamma-Tech Instruments, Inc. 303C College Road East Princeton, NJ
2 Copyright 2001 Princeton Gamma-Tech, Inc. Reproduction or publication of the contents of this manual without the permission of Princeton Gamma-Tech is prohibited. PRISM, IMIX and Spirit are registered trademarks of Princeton Gamma-Tech.
3 iii Contents 1. Introduction Unpacking and Setup Instructions Package Inspection Installation Handling Liquid Nitrogen (LN2) Safety Precautions Storage Procedures and Hazards Transport Procedures and Hazards Personal Injury Hazards and Protection About PRISM Si(Li) and HpGe Detectors Detector Types and Applications Basic Theory System Configuration X-ray Collimator Field-Effect Transistor (FET) Transistor Reset Preamplifier Fixed Z/Variable Z Detector Maintenance Standard Liquid Nitrogen Filling Procedure Filling a Dry System Establishing a Detector Efficiency Baseline Energy Resolution Wavelength-Energy Correlation Cleaning the Detector Window
4 iv PGT Detector Manual
5 v List of Figures 4.1 Representation of planar semiconductor radiation crystal Schematic diagram of the basic PRISM X-ray detector Schematic diagram of the PO-14B pulsed optical reset preamplifier Fixed Z sample/detector geometry Inclined entry system Variable Z/sample detector geometry (not drawn to scale) Energy Resolution Window cleaning procedure
6 vi PGT Detector Manual This page intentionally blank.
7 vii List of Tables 1.1 Summary of PGT PRISM 2000 Detector Types Detector Types and Applications Window Cleaning Solvents Troubleshooting Guide
8 viii PGT Detector Manual This page intentionally blank.
9 Introduction 9 1. Introduction This manual describes simple unpacking/installation, maintenance and troubleshooting procedures for PGT s PRISM series of Si(Li) and HpGe detectors. The manual also discusses the basic properties, features and applications of each detector type. Model Name Crystal Type and Size FWHM (ev) Window Type Cooling Method Si(Li), 10 mm PRISM 2000 Si(Li), 30 mm PRISM 2000 Si(Li) 60 Si(Li), 60 mm HpGe, 10 mm PRISM 2000 IG HpGe, 50 mm PRISM SLS ultra thin window for light element detection. a Liquid Nitrogen (LN 2 ) OR JT COOL Option (no LN 2 required) Table 1.1 Summary of PGT PRISM 2000 Detector Types a. All PRISM series detectors can also be ordered with a Be window or with multiple windows. Note: If you have an IMIX system with a digital pulse processor, please see Appendix 4: Digital Pulse Processors. The Avalon and Spirit systems do not use digital pulse processors. All PRISM 2000 series Si(Li) and HpGe detectors can be ordered with the JT Cool, a mechanically cooled system which does not require LN 2. If you have the JT Cool option on your system, please see the JT Cool manual for additional information.
10 10 PRISM 2000 Series Detector Manual 2. Unpacking and Setup Instructions 2.1 Package Inspection Please ask your shipping and receiving department to carefully inspect all the detector packaging materials before signing the delivery receipt presented by the delivery carrier. If any of the packaging materials appear damaged, please notify both the delivery carrier and PGT immediately. Take Polaroid pictures to document the damage. If the package has been damaged in transit, it is your responsibility to submit a claim. PGT employees will assist you in whatever way they can. 2.2 Installation Each complete system built by PGT is carefully tested and calibrated at the factory prior to shipment. Some components are disconnected before shipping to make the system easier and safer to transport. The mounting block that holds the Si(Li) detector to the electron microscope is usually shipped in place on the detector. Carefully unpack your system. Be extremely careful not to damage the window(s) when handling the detector. Keep the protective cap in place. Make sure to save the plastic protective cap and packing box in case you need to return the detector to PGT for service in the future. When you receive your detector, call PGT service to inform them that the system has arrived and is ready for installation. A PGT service engineer will perform the final interconnections and the system calibration at your site. Your detector is shipped without liquid nitrogen (LN 2 ). After unpacking the system, fill the dewar with LN 2 as soon as possible. (Before handling LN 2, see the safety information in "Section 3. Handling Liquid Nitrogen (LN2)" on page 11). Note: You can fill the detector with LN2 while it is still strapped in its shipping pallet. To prevent damage to the system, you must first remove all insulating packing materials, especially foam. Warning: Always keep thermally insulating materials away from a cold detector. This precaution is necessary to avoid damage to vacuum seals or system electronics due to excessive chilling. Allow the detector to cool down for three hours before you (or the PGT service engineer) make any electrical connections to the spectrometer. For best performance, the PGT microanalysis system requires a room with low-to-moderate humidity and a stable-voltage line free of transients.
11 Handling Liquid Nitrogen (LN2) Handling Liquid Nitrogen (LN 2 ) Liquid nitrogen (LN 2 ) is used to cool your detector to optimal operating conditions. Your system must be kept at cryogenic temperature when in use. In order to maintain the detector internal vacuum and ensure optimum long term performance, the liquid nitrogen level should be maintained on a constant basis. 3.1 Safety Precautions Before using liquid nitrogen for the first time, it is very important that you read this entire section and understand the hazards associated with storing, transporting and handling it. You must follow the correct safety procedures in order to prevent damage to the detector system or injury to yourself. See "Section 5.1 Standard Liquid Nitrogen Filling Procedure" on page 19 for instructions on how to fill your dewar. See "Section 5.2 Filling a Dry System" on page 19 for instructions on filling the dewar if your system has run dry Storage Procedures and Hazards Liquid nitrogen boils at room temperature, and the large expansion ratio as it changes from a liquid to a gas (1:692) can result in the build up of high pressures if it is stored inside a container lacking adequate venting or pressure relief provisions. Normally, your supplier will ship your LN 2 in a cylinder equipped with pressure relief valves, and you can simply monitor the settings on the pressure gauge to make sure the pressure is at a safe level. Although nitrogen gas is not toxic, it can displace oxygen and cause asphyxiation if large amounts of it are released in a small space. If you have large cylinders or tanks of liquid nitrogen, store them in a well ventilated area to avoid a buildup of nitrogen gas in your laboratory area. If you spill a large quantity of nitrogen, leave the area and ventilate it thoroughly before returning. If you use piping or transfer lines, make sure they are designed to avoid trapping LN 2 in the line. If liquid becomes trapped, high pressures may build up in the line during evaporation and cause the line to rupture or explode. If it is not possible to empty all lines, install safety relief valves and rupture disks. If you use Tygon tubing (or a similar material), periodically inspect it to check for brittleness and cracks that can cause it to rupture during transfer Transport Procedures and Hazards When you transport LN 2 from the storage cylinder to your laboratory, make sure you carry it in a container specifically designed to withstand cryogenic temperatures (approximately 77 degrees Kelvin). Transfer LN 2 only in a well-ventilated area. Many materials become brittle and can fracture if they come into contact (even briefly) with LN 2. When transporting LN 2 and filling your dewar, avoid spilling it on surrounding objects or the floor of your laboratory. You must prevent your detector electronics and the outside of the cryostat from becoming excessively cold. Take special care to avoid spilling any LN 2 on your detector components. Vent cold gas away from the system.
12 12 PRISM 2000 Series Detector Manual Personal Injury Hazards and Protection If LN 2 comes into contact with your skin it can cause severe burns similar to those resulting from hightemperature contact. Eyes are especially vulnerable to burns and damage. When handling LN 2, do not wear clothing that can collect spilled LN 2 or allow it to come into prolonged contact with your skin. Remove watches, rings, bracelets or other jewelry. It is strongly recommended that you wear the following personal protection items: Lab coat or apron. Pants without cuffs. High-topped shoes. Safety glasses or a face shield. Cryogenic gloves that are large enough to be easily slipped off in case LN 2 is spilled inside them.
13 About PRISM Si(Li) and HpGe Detectors About PRISM Si(Li) and HpGe Detectors 4.1 Detector Types and Applications Generally, Si(Li) detectors are more suitable for applications involving light element detection, while HpGe detectors offer higher spectral resolution and high-energy efficiency. Smaller crystals of either type provide better resolution than larger crystals of the same type, and larger crystals provide the highest count rates at lower beam currents. Table 4.1 provides a brief summary of the advantages of the different crystal types and sizes. Model Name Crystal Type and Size Applications/Comments PRISM 2000 Si(Li), 10 mm 2 Si(Li), 30 mm 2 This is a good detector for routine analysis. The 10 mm 2 crystal provides better resolution than the 30 mm 2. This detector is suitable for environmental and field emission SEMs, and applications where the beam current is limited. The larger crystal provides a higher count rate and better light element detection than the 10 mm 2. PRISM 2000 Si(Li) 60 Si(Li), 60 mm 2 This detector is suitable for environmental and field emission SEMs, and low-voltage applications. The large crystal provides the highest count rates at lower voltages, and superior light element detection. PRISM 2000 IG HpGe, 10 mm 2 HpGe, 50 mm 2 This crystal offers the highest available resolution, and is especially good for trace element analysis. This crystal provides good resolution and high count rate and is suitable for low voltage and low vacuum applications. Table 4.1 Detector Types and Applications 4.2 Basic Theory When a sample is put in the electron microscope and bombarded with high-energy electrons, the energy of the beam excites the sample and causes it to emit ionizing radiation. Some of this radiation is in the form of characteristic X-rays, which have unique energies corresponding to the elements from which they originate. These X-rays travel through a Be or ultra thin window to the solid-state X-ray detector. The X-rays interact with the detector (which is made of a semiconductor material) to create electron-hole pairs (see Figure 4.1). The number of electron-hole pairs created is proportional to the
14 14 PRISM 2000 Series Detector Manual energy of the radiation. If the detector crystal is Si(Li), one electron-hole pair is created for every 3.76 ev of incoming ionizing radiation. If the detector crystal is HpGe, one electron-hole pair is created for every 2.96 ev of incoming radiation. V (applied voltage) p n incoming photon d = depth of crystal p = p layer contact n = n layer contact i = intrinsic region E = energy field Figure 4.1 Representation of planar semiconductor radiation crystal The detected radiation is then efficiently converted into a measurable electrical signal which appears as an output voltage pulse with amplitude proportional to the incident photon energy. 4.3 System Configuration A basic PRISM detector system is shown in Figure 4.2. The system consists of: An X-ray collimator. See "Section X-ray Collimator" on page 15. One of the following window types (depending on your system configuration) designed to protect the detector crystal: PRISM SLS ultra thin window for light element detection. Be (Beryllium) window. Multiple windows. The Si(Li) or HpGe crystal. A field-effect transistor for signal amplification. See "Section Field-Effect Transistor (FET)" on page 15. A cryogenic enclosure (cryostat). An electronic transistor reset preamplifier. See "Section Transistor Reset Preamplifier" on page 16. A 7.5-liter dewar for holding LN 2. An optional fixed Z/variable Z adjustment feature to change the detector tilt.
15 About PRISM Si(Li) and HpGe Detectors 15 LN 2 dewar Beryllium or ultra-thin window Cold finger SEM chamber Preamplifier Electron beam Stage Variable Z Endcap (probe) in cross-section FET Collimator Si(Li) or HpGe crystal Figure 4.2 Schematic diagram of the basic PRISM X-ray detector X-ray Collimator The collimator is designed to fit over the endcap of the X-ray detector. In the SEM, using a collimator always involves a compromise between specimen working distance, spectrometer-to-specimen distance, specimen size and allowable motions, and the tightness of collimation. Generally, a more tightly collimated spectrometer will detect fewer stray X-rays produced by the backscattered electrons or other X-rays striking the pole piece, specimen chamber, or stage. The collimator, as supplied, is compatible with the user s specimen requirements. The full face of the Si(Li) crystal in the spectrometer must be "illuminated" by the X-rays generated in the specimen for maximum count rate. If the spectrometer is collimated too tightly, the count rate may be reduced because not all of the crystal is being used to detect X-rays Field-Effect Transistor (FET) The signal that originates in the detector travels to the field-effect transistor (FET) located directly behind the Si(Li) or HpGe detector crystal. Because the charge induced in the detector is extremely small, it is necessary to minimize noise (stray capacitance) by placing the FET as close to the detector as possible and operating at a liquid nitrogen temperature. All PRISM systems incorporate a thermistor and/or a platinum resistor in the detector itself that shuts off the high voltage when it senses a temperature increase. This safety feature also prevents accidental high-voltage application before cool-down is complete. Although it does not monitor the LN 2 level, an optional cable is available to detect and warn of low LN 2 levels. All the PRISM light element detectors incorporate an electron trap to deflect electrons that would otherwise cause noise in the spectrum. This assembly is not required for systems containing Be windows.
16 16 PRISM 2000 Series Detector Manual Transistor Reset Preamplifier The very small charges generated in the Si(Li) detector crystal require the use of a preamplifier. The PRISM systems use a Transistor Reset preamplifier, as shown in Figure 4.3. A unique charge reset circuit incorporated in the FET chip discharges the voltage built up on the feedback capacitor, restoring the preamplifier DC output level. This preamplifier is ideal for low noise and high count rate applications, and the performance is very close to that of an idealized charge-sensitive preamplifier. As X-ray photons are collected, the voltage at the preamplifier output begins to climb from -3 V. The output increases slowly until it reaches a predetermined DC level of. A logic circuit then activates a reset signal to a diode that injects charge into the FET of the opposite polarity to the signal charge. The voltage on the feedback capacitor is discharged and the preamplifier output returns to -3 V, and the reset signal is turned off. The reset time (dead time) is extremely short (approximately 8 s). When a reset occurs, the preamplifier circuitry also generates an inhibit output pulse that prevents data access to the microanalysis system during the time of reset. FET Logic Circuits Drain Inhibit Signal Gate HV Gate FET Drain Source Output Crystal Source Substrate Substrate Feedback Cap Feedback Cap Figure 4.3 Schematic diagram of a Transistor Reset preamplifier
17 About PRISM Si(Li) and HpGe Detectors Fixed Z/Variable Z The angle of the spectrometer in the microscope chamber (Z, tilt) is fixed in some systems and adjustable in others. In a fixed Z system with the SEM beam perpendicular to the endcap (see Figure 4.4), when the working distance of a specimen is increased the spectrometer must often be moved back in order to collect X-rays from the sample. Position A V W V = vertical distance W = working distance Position B V W Figure 4.4 Fixed Z sample/detector geometry The added distance reduces the X-ray count rate. The vertical distance (that is, the distance between the polepiece and the point where the centerline axis of the detector would break the electron beam) remains the same. Figure 4.5 illustrates the special case of an inclined entry detector. S W = V V = vertical distance W = working distance S = spectrometer distance (beam-to-detector crystal) Figure 4.5 Inclined entry system The working distance and angle are determined by the SEM manufacturer s specification. The system usually has a fixed working distance and no sample tilt. The take-off angle is constant and the count rate is a function of the solid angle (shown as the shaded triangle between the crystal and the beam). The detector endcap can be moved in and out to maximize the X-ray counts by changing the beam-todetector distance (spectrometer distance, S). In this case, the vertical distance is the same as the working distance. If the system is equipped with variable Z, the working distance will change if vz 0. Some inclined-entry systems, notably for transmission electron microscopes (TEMs) have a fixed spectrometer distance.
18 18 PRISM 2000 Series Detector Manual With a variable Z system, the analyst can change the working distance of the sample and still keep a high solid angle (and therefore, a good count rate) by changing the angle of the spectrometer (shown in Figure 4.6. Preamplifier PRISM Digital Spectrometer Detector chamber Electron beam S Z S W V max V min X control Z control Z = tilt angle V = vertical distance S = spectrometer distance W = working distance Figure 4.6 Variable Z/sample detector geometry (not drawn to scale) This changes the vertical distance. Some microscopes with small chambers or restricted entrance ports do not permit this feature.
19 Detector Maintenance Detector Maintenance Although your PGT PRISM system requires very little maintenance, there are three important procedures you must follow regularly to ensure optimum detector performance: Because your system must be kept at cryogenic temperatures in order to function properly, it is recommended that you keep the dewar filled at all times. Note: If you have the JT cool option, your system does not require LN 2. When you set up your system for the first time, you (or the PGT field service engineer) should establish a detector efficiency baseline (see "Section 5.3 Establishing a Detector Efficiency Baseline" on page 20). Repeat the calibration at appropriate intervals and compare the new efficiency data to the original baseline to assess the condition of your detector. If your detector window becomes contaminated, you must carefully clean it using the correct techniques. See "Section 5.6 Cleaning the Detector Window" on page Standard Liquid Nitrogen Filling Procedure Warning: In order to prevent serious damage to the Si(Li) or HpGe crystal, you must keep it at cryogenic temperature at all times. It is very important that you continually monitor the LN 2 level of your system, and refill the standard 7.5 liter dewar every 3-4 days. If the dewar does accidentally run out of liquid nitrogen, follow the steps in "Section 5.2 Filling a Dry System" on page 19 to bring it back to cryogenic temperature. To fill the 7.5 liter dewar with LN 2 : Remove the stopper from the dewar. Insert a large metal funnel. Using the funnel will help you to avoid spilling LN 2 on the cryostat. If the cold liquid contacts a flange which contains a vacuum seal, it is possible that the seal may be breached. Pour the LN 2 from your transport container into the system dewar from the top. 5.2 Filling a Dry System If the dewar runs out of LN 2, take the following steps: 1. The system automatically shuts off the bias voltage if the temperature rises above safe levels. Leave the bias voltage switch in the "on" position. 2. Remove the dewar cap. Make sure that the dewar is dry. Allow the detector to warm up for about 12 hours. 3. Fill the dewar with LN Re-install the dewar cap.
20 20 PRISM 2000 Series Detector Manual 5. The bias voltage will turn back on automatically when the system has stabilized at the correct operating temperature. Normally, this will take from 2-4 hours, depending on the size of your detector crystal. 5.3 Establishing a Detector Efficiency Baseline As soon as you put your system into operation, you should establish a baseline efficiency using a pure copper standard. Normally, the PGT service engineer installing your system will perform this procedure when setting up your system for the first time. Make sure that you save on disk: The spectrum for the pure copper standard. The sample-to-detector geometry and the accelerating voltage used for spectrum collection. You can use this baseline as a point of reference to assess the condition of your detector. The normal baseline calibration value is the ratio of the L alpha peak to the K alpha peak of a copper standard collected at 15 kv accelerating voltage and an X-ray takeoff angle equal to or greater than 30. You should periodically repeat this efficiency calibration under identical operating conditions. Some general guidelines are given below, but you should also take into account your SEM design, sample types, sample exchange procedure and vacuum system. If your samples are oily or dirty, your window may take less time to become dirty enough to reduce efficiency. If you have an ultra-high vacuum system, the window will probably remain cleaner for a longer time. It is recommended that you run the efficiency calibration: Every two months, if you have a light element detector. Every six months for all other detectors. After you clean the window. After any service or repair has been performed on your detector. Any time your spectrometer has been disassembled, whether for shipping or maintenance. Any change in this ratio under identical operating conditions indicates a change in detector efficiency. If this occurs, contact PGT service for help in restoring the detector to its original efficiency. One common reason for loss of detector efficiency is a dirty Be or ultra-thin window, usually from contamination from within the SEM sample chamber (often from vacuum pump oils or samples). Dirty windows have the most effect on detection of light elements. If your Be window is dirty, it probably will not significantly affect the detection of heavier elements. If the L:K ratio is 1:1 or less, it is strongly recommended that you clean your window (see "Section 5.6 Cleaning the Detector Window" on page 21 for the correct procedure), or contact PGT service to have it cleaned.
21 Detector Maintenance Energy Resolution Detector resolution is given in terms of electron volts at FWHM (full width at half maximum) for the manganese K peak from a radioactive 55 Fe source. FWHM is the width of the peak at half the maximum height, as shown in Figure 5.1. The exact value depends on the size and type of crystal, and the type of electronics. The specific value for your system is given in Appendix 3: X-ray Spectrometer Description. Resolution 129 ev Figure 5.1 Energy Resolution 5.5 Wavelength-Energy Correlation The relationship between X-ray wavelength ( in Å) and X-ray energy (E in kev) is given by the equation = or = for in nm. E E 5.6 Cleaning the Detector Window The Be or ultra thin detector window has the following functions: It protects the detector crystal from coming into direct contact with contaminants from the sample chamber (for example, vacuum pump oil or dirty samples). It maintains a vacuum seal between the detector and its electronics, and the sample chamber, especially when the sample chamber is vented. It helps maintain the cryogenic temperatures required to reduce noise. Your detector window is extremely fragile. If it becomes dirty, it can affect the efficiency of your detector. It is recommended that you periodically run a detector efficiency calibration (see "Section 5.3 Establishing a Detector Efficiency Baseline" on page 20 for information on detector resolution calibration) to monitor your detector performance. If your window is dirty, you can contact PGT service to clean it for you, or you can clean it yourself. If you choose to clean it yourself, you must use appropriate cleaning materials and follow the correct procedure. If you often run oily or dirty samples, the window will require more frequent cleaning. If you have an ultra-high vacuum system, the window will probably remain cleaner for a longer time. Table 5.1 lists the approved solvents you can use to clean the detector window.
22 22 PRISM 2000 Series Detector Manual Warning: Do not use acetone, chlorinated hydrocarbons, or any non-approved solvent to clean your detector window. If you use a non-approved solvent, you may damage your system and void your warranty. Solvent Temperature Comments Order Vertrel_XF from: Vertrel_XF (2,3- dihydroperfluoropentane) Isopropyl alcohol Liquid Freon TF Used on a cold detector. Used on a detector at room temperature. Used on either a cold or room temperature detector. Miller Stephenson George Washington Hwy. Danbury, CT (203) If frost forms on the window (generally because of condensation from the air) the endcap is too cold, and you must let the detector warm up for another six hours or so. Table 5.1 Window Cleaning Solvents To clean the detector, follow the instructions below and refer to Figure Open your SEM sample chamber so that you can access the window. If you cannot access the endcap through the sample chamber, contact PGT service for instructions. Warning: Do not permit bright light to shine on the window of a light element detector Place a lint-free cloth underneath the window to catch the solvent runoff. 3. Use an eyedropper to drip the solvent over the top of the endcap. It will flow over the window itself and carry the oils away with it. Do not squirt or spray the solvent directly onto the window. 1.The IMIX Manual (Section ) contains the following explanation of window light sensitivity: "A light element detector should not be exposed to bright light, especially infrared, because these detectors are essentially light diodes. Aluminum is sputter-coated onto the windows to reduce the problem, but cannot completely eliminate it. In addition, venting of the SEM chamber will cause these windows to flex, which can create stress cracks in the coating. Over time, this will make the detectors more light sensitive. Light sensitivity is generally not a big problem, because the detector will usually recover in a few seconds to minutes. In severe cases, such as when an IR chamber scope is used frequently, it is suggested that the detector bias be shut off while the chamber scope is in use."
23 Detector Maintenance 23 Warning: All detector windows are thin, fragile and easily broken. NEVER TOUCH THE WIN- DOWS! Beryllium is toxic. If a beryllium window breaks, isolate the fragments with tweezers and collect them with sticky tape. Store them in a sealed container and dispose of them properly. 4. Examine the window for visible oil coatings or droplets. The diagram below shows the proper technique for cleaning your detector. end view Vertrel_XF, Isopropyl alcohol or Liquid Freon TF Be or ultra-thin window endcap Si(Li) or HpGe crystal absorbent tissue collimator removed Figure 5.2 Window cleaning procedure
24 24 PRISM 2000 Series Detector Manual 6. Troubleshooting Table 6.1 lists common problems you may encounter with your detector, probable causes and suggested actions. If you are unable to diagnose or correct a problem yourself, contact PGT service at (609) Problem Probable Cause Suggested Action The dewar has moisture on the outside surfaces or is "steaming" from the filler opening. The system has poor detector resolution. There is a poor vacuum condition in the spectrometer. The loss of system vacuum may be caused by a broken entrance window or a faulty seal. The Si (Li) crystal may be warming up. There may be microphonics caused by local vibrations. Under some conditions, the CRT display of the microanalysis system may introduce noise if it is too close to the detector. There may be noise in the preamp or main amplifier. An isolation problem may exist. Call PGT service for a Return Authorization, and return the system to PGT as soon as possible. Check the LN 2 level. Try moving the CRT display away from the microanalysis system. Call PGT service. Call PGT service. With the assumption that the microscope itself is functioning properly: The system is not counting. Check the meter or setting of the bias supply to verify that bias is present. Check the preamp output with an oscilloscope to see that positive pulses are present. These are ramps with small pulses superimposed on the rising slope, varying from -3 V to +2 V. The negative edges occur during the optical resets. Observe the sawtooth output to confirm that the preamp is working correctly. The system is counting intermittently. Moisture, dirt or leakage in the bias circuit will cause the preamplifier output to saturate. Verify the condition by turning down the bias and then slowly bringing it back up. If X-rays are seen as the bias is increased, there is leakage in the bias circuit. Call PGT service. Table 6.1 Troubleshooting Guide
25 Detector Maintenance 25 Problem Probable Cause Suggested Action The system is counting intermittently. Excessive humidity will frequently cause the system to count intermittently. Large electrical transients can force the preamplifier into saturation. These transients may be transferred to the preamplifier through electromagnetic radiation or through the AC lines. Raise the bias 100V and let the detector stabilize for a minute. Then attempt collection. If the problem persists, turn off the bias supply and CAREFULLY use a hot air gun to remove the excess moisture within the preamp. Proper isolation must be provided. Call PGT service. Table 6.1 Troubleshooting Guide (Continued)
26 26 PRISM 2000 Series Detector Manual This page intentionally blank.
EDS system. CRF Oxford Instruments INCA CRF EDAX Genesis EVEX- NanoAnalysis Table top system
EDS system Most common X-Ray measurement system in the SEM lab. Major elements (10 wt% or greater) identified in ~10 secs. Minor elements identifiable in ~100 secs. Rapid qualitative and accurate quantitative
More informationAutoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:
Autoclave Safety Purpose: Sterilization refers to the complete killing of all living organisms, including spores. Common sterilization techniques include the application of wet heat, dry heat, chemicals,
More informationSDX Submersible Depth Transmitter User Manual
SDX Submersible Depth Transmitter User Manual January 2011 USER INFORMATION Stevens makes no warranty as to the information furnished in these instructions and the reader assumes all risk in the use thereof.
More informationGamma and X-Ray Detection
Gamma and X-Ray Detection DETECTOR OVERVIEW The kinds of detectors commonly used can be categorized as: a. Gas-filled Detectors b. Scintillation Detectors c. Semiconductor Detectors The choice of a particular
More informationRefrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
More informationView of ΣIGMA TM (Ref. 1)
Overview of the FESEM system 1. Electron optical column 2. Specimen chamber 3. EDS detector [Electron Dispersive Spectroscopy] 4. Monitors 5. BSD (Back scatter detector) 6. Personal Computer 7. ON/STANDBY/OFF
More informationSilicon Drift Detector Product Brochure Update 2013
Silicon Drift Detector Product Brochure Update 2013 Content Classic Silicon Drift Detector High Resolution Silicon Drift Detector Multielement Silicon Detector Extra Large Detector Series July 2013 About
More informationRISK ASSESMENT: HANDLING, TRANSPORTATION AND STORAGE OF LIQUID NITROGEN AND OTHER CRYOGENIC MATERIAL
RISK ASSESMENT: HANDLING, TRANSPORTATION AND STORAGE OF LIQUID NITROGEN AND OTHER CRYOGENIC MATERIAL More information can be found in the liquid nitrogen section of the departmental Health & Safety webpages:
More informationSubminiature Load Cell Model 8417
w Technical Product Information Subminiature Load Cell 1. Introduction... 2 2. Preparing for use... 2 2.1 Unpacking... 2 2.2 Using the instrument for the first time... 2 2.3 Grounding and potential connection...
More informationActivitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies
Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies (Ci), where 1 Ci = 3.7x10 10 disintegrations per second.
More informationPrecision Miniature Load Cell. Models 8431, 8432 with Overload Protection
w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force
More informationUltrasonic support removal tank
Ultrasonic support removal tank User guide and safety manual See inside for use and safety information. The Ultrasonic support removal tank automatically removes PLA support material from a printed ABS
More informationHeating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
More informationTA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER (DSC) Insert Nickname Here. Operating Instructions
TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER (DSC) Insert Nickname Here Operating Instructions Table of Contents 1 INTRODUCTION Safety 2 Sample Preparation 3 2 BACKGROUND Background Information 4 Resources
More informationPC1130 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1130 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
More informationCompressed Gas Cylinder Storage and Handling Guide
Overview Compressed gas cylinders are used in many workplaces to store gases that vary from extremely flammable (acetylene) to extremely inert (helium). Many compressed gas cylinders are stored at extremely
More informationAmplified High Speed Fiber Photodetectors
Amplified High Speed Fiber Photodetectors User Guide (800)697-6782 sales@eotech.com www.eotech.com Page 1 of 7 EOT AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE Thank you for purchasing your Amplified
More informationVCR Ion Beam Sputter Coater
VCR Ion Beam Sputter Coater Sputtering Process and Rates 2 Vacuum System 3 Loading the Sputter Chamber 4 Sputter Coating 5 Removing Samples from Chamber 6 Appendix A: VCR High Vacuum Gauge Conditioning
More informationAMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE
AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE Thank you for purchasing your Amplified High Speed Fiber Photodetector. This user s guide will help answer any questions you may have regarding the
More informationThe photoionization detector (PID) utilizes ultraviolet
Chapter 6 Photoionization Detectors The photoionization detector (PID) utilizes ultraviolet light to ionize gas molecules, and is commonly employed in the detection of volatile organic compounds (VOCs).
More informationRI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
More informationOil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
More informationPC1131 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
More informationModel 1756 Test Lead Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you
More informationHygro-Thermometer + InfraRed Thermometer Model RH101
User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
More informationPBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
More informationInstallation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
More informationTroubleshooting accelerometer installations
Troubleshooting accelerometer installations Accelerometer based monitoring systems can be tested to verify proper installation and operation. Testing ensures data integrity and can identify most problems.
More informationThe Basics of Scanning Electron Microscopy
The Basics of Scanning Electron Microscopy The small scanning electron microscope is easy to use because almost every variable is pre-set: the acceleration voltage is always 15kV, it has only a single
More informationUser s Manual. Copyright 2014 Trick Technologies Oy
User s Manual Copyright 2014 Trick Technologies Oy Catchbox Pro Module Catchbox Cover Contents 1 Safety Instructions...4-5 2 Quick Start... 6-15 3 Product Description... 16-18 Overview...16 Compatibility...17
More informationFailure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
More informationDRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More informationNational- Spencer Inc.
9-27-2010 National- Spencer Inc. 19.2V HEAVY DUTY GREASE GUN PRODUCT SPECIFICATION Charger Input Power 110 VAC Battery Output Power 19.2V Battery Capacity 1500 MAH Battery Pack Charge Time 1 Hour Maximum
More informationCathode Ray Tube. Introduction. Functional principle
Introduction The Cathode Ray Tube or Braun s Tube was invented by the German physicist Karl Ferdinand Braun in 897 and is today used in computer monitors, TV sets and oscilloscope tubes. The path of the
More informationPowlVac Vacuum Integrity Tester
Instructions IB-60025B PowlVac Vacuum Integrity Tester POWELL ELECTRICAL MANUFACTURING COMPANY 8550 MOSLEY DRIVE HOUSTON, TEXAS 77075 USA PHONE (713) 944-6900 FAX (713) 947-4453 www.powellelectric.com
More information3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
More informationHydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
More informationIMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
More informationPUMPED Nd:YAG LASER. Last Revision: August 21, 2007
PUMPED Nd:YAG LASER Last Revision: August 21, 2007 QUESTION TO BE INVESTIGATED: How can an efficient atomic transition laser be constructed and characterized? INTRODUCTION: This lab exercise will allow
More informationADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
More informationActive Monitor Box McCrypt S.T.E.V.E. 15. Order No. 30 17 06
Active Monitor Box McCrypt S.T.E.V.E. 15 Order No. 30 17 06 1 McCrypt Active Monitor 15 Introduction Dear Customer, Thank you for purchasing this McCrypt Active Monitor. You have chosen a quality product
More informationAutomotive Electronics Council Component Technical Committee
AEC - Q101-005 - REV- ATTACHMENT 5 AEC - Q101-005 Rev- CAPACITIVE DISCHARGE MODEL (CDM) ELECTROSTATIC DISCHARGE (ESD) TEST METHOD - 005 DISCRETE COMPONENT CHARGED DEVICE MODEL (CDM) ELECTROSTATIC DISCHARGE
More informationE. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE
E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE References for Nuclear Magnetic Resonance 1. Slichter, Principles of Magnetic Resonance, Harper and Row, 1963. chapter
More informationSECTION 13. Multipliers. Outline of Multiplier Design Process:
SECTION 13 Multipliers VMI manufactures many high voltage multipliers, most of which are custom designed for specific requirements. The following information provides general information and basic guidance
More informationELECTRON SPIN RESONANCE Last Revised: July 2007
QUESTION TO BE INVESTIGATED ELECTRON SPIN RESONANCE Last Revised: July 2007 How can we measure the Landé g factor for the free electron in DPPH as predicted by quantum mechanics? INTRODUCTION Electron
More information3620 W 11th Streetб Houston, TX 77008 Telephone: 713-635-6291 Email: sales@kellogg-american.com Website: www.kellogg-american.com
Unpackaging & Handling Be sure to carefully inspect the unit before accepting the shipment. If any damage has occurred document it with the trucking company immediately. Contact your Kellogg Distributor
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
More informationaseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
More information! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
More informationSWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
More informationTutorial 4.6 Gamma Spectrum Analysis
Tutorial 4.6 Gamma Spectrum Analysis Slide 1. Gamma Spectrum Analysis In this module, we will apply the concepts that were discussed in Tutorial 4.1, Interactions of Radiation with Matter. Slide 2. Learning
More informationUSER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920
USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 [This page intentionally left blank] Warning for Your Protection 1. Read these instructions. 2. Keep these
More informationFOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK
FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK If you have any questions about the operation of your fireplace heater, please contact Crane Customer Care. Toll Free: 888-599-0992
More informationSUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
More informationSEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor
INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone:
More informationFlushing and Cleaning the A/C System
Flushing and Cleaning the A/C System Once an AC system has been contaminated or has suffered a failure, the most important part of the AC service to restore the cooling performance to the system = FLUSHING
More informationHow To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
More informationIf you have any questions about how to safely undertake a task or project, ask your supervisor before you begin.
Laboratory Health and Safety Manual Section 1: Introduction and Objectives This manual provides a set of minimum standards and practices for the safe and healthy operation of a laboratory. Following the
More informationInfrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
More informationOutages Happen 24/7 So Should Monitoring / SAFEGUARD YOUR HIGH VOLTAGE ASSETS WITH VAISALA ONLINE MONITORING
Outages Happen 24/7 So Should Monitoring / SAFEGUARD YOUR HIGH VOLTAGE ASSETS WITH VAISALA ONLINE MONITORING A Small Investment to Generate Measurable Benefits Sometimes, solving challenges is surprisingly
More informationDUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D
ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &
More informationCongratulations! Thank you!
TM-47 ORDERCODE D1370 Congratulations! You have bought a great, innovative product from DAP Audio. The DAP Audio Microphone range brings excitement to any venue. Whether you want simple plug-&-play action
More informationAdjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
More informationBroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
More informationCONTROL METHODS. There are five ways to control the release of asbestos fibers:
Control Methods CONTROL METHODS When asbestos containing materials are found in a building, the owner must decide which method or methods will be used to deal with the asbestos. The decision will be based
More informationQUASAR ELECTRONICS KIT No. 1015 ELECTRONIC MOSQUITO REPELLER
QUASAR ELECTRONICS KIT No. 1015 ELECTRONIC MOSQUITO REPELLER General Description This simple circuit can prove itself worth many times its value (which is very reasonable anyway) in getting rid of mosquitoes
More informationFT-100 Fire Training Fog Machine User Manual English
FT-100 Fire Training Fog Machine User Manual English 2015 Antari Lighting and Effects Ltd. User Manual - English Safety Information Please read the following safety information carefully before operating
More informationTrouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
More informationS O SSM. Services. Cat. Management Guide. Accurate Analysis Improved Cost Control Optimized Performance
S O SSM Services Cat Management Guide Accurate Analysis Improved Cost Control Optimized Performance Contents S O S SM Services introduction... 3 Making the most of S O S Services...4-5 Good equipment health
More information81000 Series Aluminum Gate Valve Installation and Repair Manual
High Vacuum Valves Leader in Quality and Value 81000 Series Aluminum Gate Valve Installation and Repair Manual Dear Customer, Thank you for choosing HVA as your vacuum valve supplier. Your valve will give
More informationPASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE
MODEL HAA51 PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE OPERATING MANUAL HAA51 PASSIVE INFRARED INTRUDER DETECTOR INTRODUCTION HAA51 Passive Infrared
More informationATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
More informationCONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS
CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS BULLETIN 240-10-3 June 2004 Supersedes June 1983 Many centrifugal systems get little maintenance. As a result they operate with the refrigerant highly contaminated
More informationIon Beam Sputtering: Practical Applications to Electron Microscopy
Ion Beam Sputtering: Practical Applications to Electron Microscopy Applications Laboratory Report Introduction Electron microscope specimens, both scanning (SEM) and transmission (TEM), often require a
More informationLEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells
Engineering Production Sales LEAD CRYSTAL Valve-regulated lead-crystal batteries Energy storage Cells User Manual www.axcom-battery-technology.de info@.axcom-battery-technology.de Chapter 1: 1. Introduction
More informationARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
More informationInfrared Viewers. Manual
Infrared Viewers Manual Contents Introduction 3 How it works 3 IR viewer in comparison with a CCD camera 4 Visualization of infrared laser beam in mid-air 4 Power Density 5 Spectral sensitivity 6 Operation
More informationHydraulic Troubleshooting PRESENTED BY
Hydraulic Troubleshooting PRESENTED BY NORMAN KRONOWITZ Introduction Welcome to the CMA/Flodyne/Hydradyne s Hydraulic Troubleshooting presentation. We will introduce many aspects of troubleshooting hydraulic
More informationCERAMIC XENON LAMPS APPLICATIONS FEATURES & BENEFITS VAC CERAMIC XENON LAMPS
Form No. S-VAC/R-115 CERAMIC XENON LAMPS VAC CERAMIC XENON SERIES VAC CERAMIC XENON LAMPS America, a respected leader in specialty lighting, brings you the latest advancement in lamp technology - our new
More informationHSeries. High Power High Quality. Ultra-High Speed, Sensing Ionizer SJ-H Series
NEW Ultra-High Speed, Sensing Ionizer SJ-H Series High Power High Quality Suitable for high-speed static elimination in wide areas, including clean room environments HSeries The highest static elimination
More informationSelect Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
More informationTHE NEWCASTLE UPON TYNE HOSPITALS NHS FOUNDATION TRUST SAFE USE AND STORAGE OF LIQUID NITROGEN AND SOLID CARBON DIOXIDE (DRY ICE)
THE NEWCASTLE UPON TYNE HOSPITALS NHS FOUNDATION TRUST SAFE USE AND STORAGE OF LIQUID NITROGEN AND SOLID CARBON DIOXIDE (DRY ICE) GUIDANCE AND INFORMATION Effective: February 2007 Review February 2010
More informationSLLP-5630-150-G PRODUCT DATASHEET. RoHS Compliant
PRODUCT DATASHEET SLLP-5630-150-G Table of Contents Features... 1 Applications 1 Characteristics.. 1 Typical Electro optical Characteristics Curves... 3 Mechanical Dimensions... 4 Carrier Tape Dimensions.....
More information1 / 4 IN. FFL x 4 FT. 9 IN. 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2% Set includes Quick Disconnect Valves
Specifications Blue (Low) Gauge 0-120 PSI Blue Hose 1 / 4 IN. FFL x 4 FT. 9 IN. Red (High) Gauge 0-500 PSI Red Hose 1 / 4 IN. FFL x 4 FT. 9 IN. Yellow Hose 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2%
More informationDigital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger
Digital echo-charge Owner s Manual Xantrex Digital echo-charge Battery Charger Thank you for purchasing a Xantrex Digital echo-charge. Xantrex Technology Inc. takes pride in manufacturing quality products
More informationExperiment 5. Lasers and laser mode structure
Northeastern University, PHYS5318 Spring 2014, 1 1. Introduction Experiment 5. Lasers and laser mode structure The laser is a very important optical tool that has found widespread use in science and industry,
More informationVolkswagen Golf 5 2004-> VW Rabbit GTI 2006->
Стр. 1 из 24 Volkswagen Golf 5 2004-> VW Rabbit GTI 2006-> 19-1 Cooling system components Warning! Hot steam may escape when opening expansion tank. Wear protective goggles and protective clothing to prevent
More informationBB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
More informationGENERAL INSTALLATION MANUAL FOR EGING PV MODULES
GENERAL INSTALLATION MANUAL FOR EGING PV MODULES PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE MODULES. PLEASE PASS ALONG THE ATTACHED USER MANUAL TO YOUR CUSTOMER. 1. INTRODUCTION This
More informationFailure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
More informationWARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:
Revision Level: 01 Revision Date: 07/07/2011 Please read all instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Air Purifier. Failure to do
More informationOASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
More informationDetermining the Quantity of Iron in a Vitamin Tablet. Evaluation copy
Determining the Quantity of Iron in a Vitamin Tablet Computer 34 As biochemical research becomes more sophisticated, we are learning more about the role of metallic elements in the human body. For example,
More informationCL90i. 77-021 Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser
3 - Beam Self-Leveling Cross Line Laser CL90i 77-01 Please read these instructions before operating the product Self-Leveling GB D F I E PT NL DK SE FIN NO PL GR CZ RU HU SK SI BG RO EE LV LT Contents
More informationGLYCOL CHILLER SYSTEM TROUBLESHOOTING 101
GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101 By Jim VanderGiessen Jr, Pro Refrigeration Inc. There is a good chance your glycol chiller system is often completely forgotten about, until that dreaded day you
More informationThermopile Support: FAQs, Troubleshooting, Care & Maintenance
Thermopile Support: FQs, Troubleshooting, Care & Maintenance Table of Contents 1. Introduction 2. How long does a thermopile sensor last and how accurate does it remain over time? 3. What are typical causes
More informationMaking the Most of SáOá SM Services
MAINTENANCE PRODUCTS AND SERVICES Making the Most of SáOá SM Services With S O S Services, you don t just get test results, you get accurate analysis from the people who know your Cat equipment best. Your
More information12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
More information