Installation manual HIGH WALL SPLIT AIR CONDITIONER
|
|
|
- Laurence Edgar Ball
- 10 years ago
- Views:
Transcription
1 Installation manual HIGH WALL SPLIT AIR CONDITIONER
2
3 INSTALLATION & REPAIR GUIDE Split Wall-Mounted Air Conditioner *Selection of installation positions for indoor unit* * To be installed at the position where the air delivered from the unit can reach every corner of the room; * To avoid being affected by the outdoor air; * To avoid blockage to the air inlet or outlet of the unit; * To avoid too much oil smoke or steam; * To avoid possible generation, inflow, lingering or leakage of flammable gases; * To avoid high-frequency facilities (such as high frequency arc welders, etc.); * To avoid the places where acid solutions are frequently used; * To avoid the places where some special sprayers (sulfides) are frequently used. * Not to install a fire alarming device near the air outlet of the unit (during operation, the fire alarm device might be erroneously triggered by the warm air from the unit); * Make sure of enough space for installation and maintenance. * To take into consideration the operational convenience and safety in installation, it is recommended to ensure enough space between the unit and the walls. Ceiling Above 100mm(4") Left side: 150mm(6") and above Right side: 150mm (6") and above Wall hanging plate 2300mm(7'6") and above * Height limits of indoor and outdoor units. ground * Either the indoor unit or the outdoor unit can be higher, but the height difference must comply the stated requirements. * Try to reduce the bending of the piping line as much as possible so as to avoid possible negative impacts upon the performances of the units. Indoor unit 5m(16'5")max. outdoor unit 1
4 INSTALLATION & REPAIR GUIDE Split Wall-Mounted air conditioner *Selection of installation positions for outdoor unit* * To install the outdoor unit at the places which can stand the load of the machine weight and will not cause big vibrations and noises; * To install the unit at the places not to be exposed to rain or direct sunshine, and the places with good ventilation; * The noises generated from the unit will not affect the neighboring places; * Do not install the unit on non-metal frame; * Not to install the unit at the places where there might occur the generation, inflow, stay or leakage of inflammable gases; * Pay attention to the drainage of the condensed water from the base plate during operations; * To avoid the air outlet being directly against the wind. Detailed space requirements around the outdoor unit 1. When there are obstacles above the unit 500mm(1'8") min 100mm(4") min 2. When the front (air outlet) is open 3. When there are obstacles only in the front (air outlet) 200mm(8") min 200mm(8") min 300mm(1') min 500mm(1'8") min Space for maintenance Shown as in the following figure. Keep the maintenance space in front of the unit. 200mm (8")min 500mm(1'8") min 4. When there are obstacles at the front and rear sides. 500mm (1'8")min Space for maintenance 100mm(4") min 5. When there are obstacles all around the unit on four sides. Although the top side is open, the installation is not to be done if there are obstacles all around. 1000mm(3'4") min * At least two sides should be kept open. 2
5 *Installation fixture of indoor unit* INSTALLATION & REPAIR GUIDE Split Wall-Mounted air conditioner 1.Installation of wall-mounting plate Fix the wall-mounting plate firmly on the wall with screws. Make sure of the leveling of the plate. Slanted wall-mounting plate might jeopardize the smooth discharge of the condensed water. 2.Drill holes on the wall Drill holes at places slightly below the wall-mounting plate, with hole diameter of 65mm(2-3/5") and the outer edge of the hole 5-10mm(1/5-2/5") lower (Fig.2) so that the condensed water can smoothly flow out. Cut the wall penetrating pipe to proper length according to the thickness of the wall (3-5mm(1/10-1/5") longer than the wall thickness) and insert the pipe as indicated in Fig.2. Fig.2 Wall cap Fix with a tape Wall pipe Interior Wall 5-10mm lower (1/5-2/5") Exterior 3.Installation of drain pipe Install the pipelines of the indoor unit in accordance with the direction of the wall holes. Wrap tightly the drain pipe and the pipelines with tape. Make sure that the drain pipe is underneath the pipelines. (Fig.3) (When the drain pipe passes the room interior, some condensed water might occur to its surfaces if the humidity is very high). Fig.3 Drain pipe Pipelines of indoor unit Rear pipe 4.Installation of indoor unit Pass the connection wires, connecting pipelines and drain pipe through the wall hole. Hang the indoor unit on the hooks at the top of the wall-mounting plate so that the hooks at the bottom of the indoor unit match the hooks of the wall-mounting plate. (Fig.4) Fig.4 Top hooks Hook supports Bottom hooks 3
6 INSTALLATION & REPAIR GUIDE Split Wall-Mounted air conditioner Inspections: a. Check if the hooks at the top and bottom are firmly fixed. b. Check if the position of the master unit is properly leveled. c. The drain pipe should not curve upward (Fig.5). d. The drain pipe should be at the lower part of the wall pipes (Fig. 5). Connecting wires Drain pipe Fig.5 Connecting pipe Wall pipe Drain pipe *Installation fixture of outdoor unit* * Try to ship the product to the installation location in its original package; * As the gravity center of the unit is not at the installation center, special caution should be taken when using hoisting cables to lift it up; * During shipping, the outdoor unit must not be slanted to over 45 degrees (Do not store the unit in a horizontal way). * Use expansion bolts to fix the mounting supports on the wall; * Use bolts and nuts to fix the outdoor unit firmly on the supports and keep on the same level; * If the unit is installed on the wall or at the rooftop, the supports have to be firmly fixed so as to resist earthquake or strong wind. Dimensions for parallel units installations 300mm(1')min 4
7
8 INSTALLATION & REPAIR GUIDE Split Wall-Mounted air conditioner *Pipelines connection * *Ordinary pipelines connection (it is suitable for non-quick coupler) No dust,foreign articles,air or moisture should be allowed to enter the air conditioning system.careful attention should be paid when pipeline connection for outdoor unit is made.try to avoid repeated curves as much as possible,otherwise hardening or cracks might be caused to the copper pipes.suitable wrenches should be used when the pipeline connection is done so as to ensure appropriate torque(refer to following torque Table 1).Excessive torque might damage the joints while too little torque might lead to leakage. Table 1 Torque based upon the wrench to be used 6.35(1/4") 9.52(3/8") 12.7(1/2") 15.88(5/8") 19.05(3/4") Tightening torque 160kgf.cm(63kgf.inch) 300kgf.cm(118kgf.inch) 500kgf.cm(197kgf.inch) 750kgf.cm(295kgf.inch) 1200kgf.cm(472kgf.inch) Strengthened tightening torque 200kgf.cm(79kgf.inch) 350kgf.cm(138kgf.inch) 550kgf.cm(216kgf.inch) 800kgf.cm(315kgf.inch) 1400kgf.cm(551kgf.inch)
9 INSTALLATION & REPAIR GUIDE Split Wall-Mounted Air Conditioner Air Purging Air purging With Vacuum Pump 7
10 INSTALLATION & REPAIR GUIDE Split Wall-Mounted air conditioner 8
11 9 INSTALLATION & REPAIR GUIDE Split Wall-Mounted Air Conditioner
12 INSTALLATION & REPAIR GUIDE Split Wall-Mounted air conditioner *Connection of power cable* 1.Remove the drawer of the outdoor unit. Fig.7 2.Connect the indoor power and control wires with the matched outdoor wires in accordance with the electric schematic diagram and make sure that the connection is firmly done(fig.7) 3.Use a press plate to fix the wires firmly,and re-install the drawer. wire pressing plate Drawer screw Note:Do not connect the wires in a wrong way,otherwise electric malfunctions will be caused and even damages to the units will occur.the appliance shall be installed in accordance with national wiring regulation.if the supply cord is damaged,it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.the plug shall be accessible after installing the appliance.if the model have not plug that a switch which have a contact separation of at least 3 mm(1/10") in all poles shalled be added in fixed wiring. *Finishing touches * * Use thermal tube to wrap the joints and wrap the tube tightly with ethylene tapes. * Fix the wrapped pipelines on the exterior wall with clamps. * Fill in the gaps left over by the pipeline hole and wall hole to prevent rain-water from entering. *Test running* * Connect to the power source,check if the function selection keys on the remote controller are working properly. * Check if the room temperature adjustments and timer settings are working properly. * Check if the drain is smooth. * Check if there is any abnormal noise or vibration during operation. * Check if there is leakage of refrigerant. *Is the unit installed correctly? * *Suitable Installation Position *Isn't there anything which prevents ventilation or obstructs operation in front of the indoor unit? Do not install the unit following place. *Inflammable gases may leak. *Oil splashes a lot. *In case where the unit is used in such places as poisonous or sultry gases are generated or seaside district exposed to sea breezes corrosion may cause malfunction. Consult with your distributor. *Air conditioner body and remote controller must be I m(39-3/4") or more away from a TV or a radio. Drain the dehumidified water from the indoor unit to a place which drains well. *Pay attention to operation noise *When installing the unit, choose a place which can stand the weight of the unit well and does not increase the operation noise or vibration. Especially where there is a possibility that vibration be transmitted to the house, fix the unit by inserting attached vibration -proof pads between the unit and fittings. 10
13 INSTALLATION & REPAIR GUIDE Split Wall-Mounted Air Conditioner *Choose the place where hot air and operation noise from the outlet of the outdoor unit do not annoy the neighborhood. *Things left near the outlet and inlet of the outdoor unit cause malfunction or increased operation noise. Do not leave obstacles near the outlet and inlet. *If irregular sound is heard during operation, consult with your distributor. *Inspection and Maintenance *According to the service conditions and operating environment, the inside of the air conditioner will become dirty after several seasons (3 to 5years ) of service, resulting in decreased operating performance.inspection and maintenance are recommended in addition to usual cleaning (The air conditioner can be used for a longer period and without anxiety.) *As to inspection and maintenance, consult your dealer or any one of business offices of dealing companies.(service charge is required in this case.) *We recommend to perform inspection and maintenance during an off seasons. *Self Diagnosis Functions* Our company provides the thoughtful services for customer,air conditioners had been installed self diagnosis system to display the information for the units. Self-check information Digital self-check code Indoor and outdoor communication failure Indoor temperature sensor failure F1 F2 Indoor coil air outlet /inlet/midpoint temperature sensor failure Defrosting Outdoor transducer module protection failure Excessive outdoor current Outdoor compressor air exhaust temperature too high/outdoor ambient temperature too high /compressor encloser temperature switch break off/module temperature too high Outdoor direct current generatrix voltage abnormity Lack of fluorin or conversion valve failure Outdoor sensor failure Outdoor unit drive failure/compressor startup failure Outdoor fan failure F3 DF P2 P3 P4 P7 P8 F6 FC FF Note:Above self check information is commonly applicable in our most air conditioners,but some are special,you can refer to the User's Manual for information or contact the dealer or authorized maintenance people for help. 11
14 12
15 13
16 14
17 15
18 Hong Kong Amcor Ltd Suite 2007, Tower 6, The Gateway, Harbour City, 9 Canton Road, Tsim Sha Tsui, Kowloon, Hong Kong Tel: Fax: [email protected] United Kingdom Amcor Ltd 9 Ryan Drive, West Cross Centre, Great West Road, Brentford, Middlesex, TW8 9ER, United Kingdom Tel: Fax: [email protected] USA Amcor Inc. 685A Gotham Parkway, Carlstadt, New Yersey 07072, United States of America Tel: Fax: [email protected] The Netherlands Amcor B.V. Anton Philipsweg 9-11, 1422 AL Uithoorn, The Netherlands Tel: Fax: [email protected] Israel Amcor International Ltd 3 Sapir Street, Herzelia Pituach, 46733, Israel Tel: Fax: [email protected] Singapore Amcor Investments (Singapore) Pte Ltd 545 Orchard Road, #13-02, Far East Shopping Centre, Singapore Tel: Fax: [email protected] Amcor (Guangzhou) Ltd - China Room 2903, 29/F Renfeng Tower, 490 Tianhe Road, Tianhe District, Gianzhou, China Tel: Fax: [email protected] Amcor Ltd - Dong Guan, China 8/F Changwang Bldg, Dongxing Road Changping Town, Dongguan City, Guangdong Province, China Tel: Fax: [email protected] Amcor Industries Ltd - China Factory Xialiao village, Iongxi Town, Boluo County, Huizhou City Guandong Province, China Tel: Fax: [email protected] CM C US
INSTALLATION AND REPAIR GUIDE Split Wall-Mounted Air Conditioner
INSTALLATION AND REPAIR GUIDE Split Wall-Mounted Air Conditioner Foreword Air conditioners are units that should have the professional technicians do the installation for you. This Instruction Guide is
Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español
Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2
SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with
Ductless Split Air Conditioner
Ductless Split Air Conditioner Installation Manual Indoor HSU09VHG(DB)-W HSU12VHG(DB)-W HSU18VHH(DB)-W HSU24VHG(DB)-W Outdoor HSU09VHG(DB)-G HSU12VHG(DB)-G HSU18VHH(DB)-G HSU24VHG(DB)-G Table of Contents
ROOM AIR CONDITIONER INSTALLATION MANUAL
ROOM AIR CONDITIONER INSTALLATION MANUAL ( Split Type) Please read this installation manual completely before installing the product When the power cord is damaged, replacement work shall be performed
HP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
Reverse Cycle Inverter Split System Air Conditioner
Reverse Cycle Inverter Split System Air Conditioner Model Number TAC-09CHSA/JAI5 INSTALLATION MANUAL Contents 03 Warranty Details 04 Welcome 05 General Safety Instructions 06 Product Overview 07 Selecting
CEILING CASSETTE FAN COIL UNIT
CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
AIR CONDITIONER INSTALLATION MANUAL
FRANCAIS ESPAÑOL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring
Split Air Conditioner
Split nditioner plit itsplit ir onditioner Split Split Split Split Split User s WNER'S 'S ER'S For s: AWI/AWO-21HPR1 Delta AWI/AWO-25HPR1 Delta AWI/AWO-32HPR1 Delta AWI/AWO-53HPR1 Delta AWI/AWO-65HPR1
Split Air Conditioner
Split Air Conditioner Thank you for choosing our product. For proper operation, please read and keep this manual carefully. If you have lost the Owner s Manual, please contact the local agent or visit
Failure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
Hi Wall Split Air Conditioners
R22 220-240V ~, 50Hz Hi Wall Split Air Conditioners 53KHET 12-18-24 Cool Only 53QHET 12-18-24 Heat Pump INSTALLATION MANUAL Carrier is committed to continuously improving its products according to national
Taurus Series YORK Window Air Conditioners
Taurus Series YORK Window Air Conditioners IOM IOWRCAG50220711A1 Warning 1. Before using the Air conditioner please read the instructions carefully. They contain important advise about the installation,
USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL
USER S MANUAL Duct Type Series MH MH FEEA Series FUEA Series ENGLISH ESPAÑOL PORTUGUÊS E HNIKA DEUTSCH ITALIANO FRANÇAIS Free Joint Multi Air Conditioner (Cooling and Heating) E S F I P D G DB98-29565A(1)
SPLIT WALL MOUNTED TYPE AIR CONDITIONERS INSTALLATION HANDBOOK
SPLIT WLL MOUNTED TYPE IR CONDITIONERS INSTLLTION HNDBOOK Thank you for choosing our ir Conditioner. Please read this INSTLLTION HNDBOOK carefully prior to installing and keep it for further reference.
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
Wall Mounted Mini Split Heat Pump Air Conditioner
Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFIHP-09-ID / KFHIP-09-OD KFHHP-12-ID / KFHHP-12-OD Indoor Unit. Outdoor Unit. Thank you for selecting Soleus
ALL IN ONE. Heat Pump Water Heater
ALL IN ONE Heat Pump Water Heater INSTALLATION AND OPERATION INSTRUCTIONS Please read this user s manual carefully before operate the unit. www.airtradecentre.com CONTENTS A. IMPORTANT REMARKS ------------------------------------------------------------------------------------------------
Wall Mounted Mini Split Heat Pump Air Conditioner
Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFHHP-18-ID / KFHHP-18-OD Indoor Unit. Outdoor Unit. Thank you for selecting Soleus Air. To ensure proper operation,
SPLIT -TYPE ROOM AIR CONDITIONER
Before using your air conditioner, please read this manual carefully and keep it for future reference SPLIT -TYPE ROOM AIR CONDITIONER Please read this installation manual completely before installing
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
LG Floor Standing Type Air Conditioner INSTALLATION MANUAL
website http://www.lgservice.com e-mail http://www.lgeservice.com/techsup.html LG Floor Standing Type Air Conditioner INSTALLATION MANUAL LG IMPORTANT Please read this installation manual completely before
CENTRAL AIR CONDITIONER SPLIT SYSTEM
CENTRAL AIR CONDITIONER SPLIT SYSTEM WITH ELECTRONIC CONTROL SERIES BS BS 30E BS 36 BS 43 INSTALLATION INSTRUCTIONS SUMMARY GENERAL...3 SELECTING THE LOCATION OF UNITS...5 RELATIVE LOCATION OF THE UNITS...5
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
Air Conditioner Water Heater Model ACWH18
Air Conditioner Water Heater Model ACWH18 Installation Guide IMPORTANT! READ THIS FIRST! Commissioning of this unit must be done by a licensed HVAC technician. Commissioning includes making the electrical
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS
CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS Please read this instruction sheet completely before installing the product. When the power cord is damaged, replacement work should be
USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
Inverter Room Air Conditioner Installation Manual KSV26CRE, KSV26HRE, KSV35CRE, KSV35HRE, KSV53HRE, KSV62HRE, KSV70CRE, KSV70HRE, KSV80HRE
Inverter Room Air Conditioner Installation Manual KSV26CRE, KSV26HRE, KSV35CRE, KSV35HRE, KSV53HRE, KSV62HRE, KSV70CRE, KSV70HRE, KSV80HRE Refrigerant R32 Congratulations Contents Congratulations and thank
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Wall Mounted Inverter Split Air Conditioner with Heat Pump
Wall Mounted Inverter Split Air Conditioner with Heat Pump User and Installation Manual eiq-9wminv 9,000 BTU eiq-12wminv 12,000 BTU eiq-18wminv 18,000 BTU eiq-24wminv 24,000 BTU also quick connectors (QC)
Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
1. BEFORE INSTALLATION
ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL JG79A191H03 MSZ-GE06/09/12/15/18NA MSY-GE09/12/15/18NA When installing multi units, refer to the installation manual of the multi unit for outdoor
AIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM INSTALLATION MANUAL
HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM INSTALLATION MANUAL Models: CROWN09HP230V1A CROWN12HP230V1A CROWN18HP230V1A Thank you for choosing a Crown High-Wall Unit for your customer. Please
10 tips for getting more reliability from your air-conditioning system [reliability]
10 tips for getting more reliability from your air-conditioning system [reliability] A guide for installers, specifiers, contractors and architects February 2010 10 tips for getting more reliability from
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
Owner s Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E. Model name:
AIR CONDITIONER (SPLIT TYPE) Indoor Unit Not accessible to the general public Model name: 4-way Air Discharge Cassette Type RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E Air conditioner (Split
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Ramsond Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
PORTABLE AIR CONDITIONER
PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION
CENTRAL AIR CONDITIONER SPLIT SYSTEM
CENTRAL AIR CONDITIONER SPLIT SYSTEM WITH ELECTRONIC CONTROL SERIES DNC INSTALLATION INSTRUCTIONS Table of Contents 1. List of accessories provided with the air-conditioner... 1 2. General... 2 2.1 Indoor
WINDOW ROOM AIR CONDITIONER
WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please
Floor Type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA. English
Floor Type Air-Conditioner MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA INSTALLATION MANUAL This manual only describes the installation of indoor unit. When installing the outdoor unit, refer to the installation manual
Installation Manual. BYD Wall-mounted AC Charging Box
Installation Manual BYD Wall-mounted AC Charging Box BYD Wall-mounted AC Charging Box Installation Manual Version/Revision: A/0 Dedicated Service Commitment from BYD Auto Dear valuable customers: We are
Vertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller
Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone:
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
Inverter Air Conditioner Installation Manual. KSV25CRF, KSV35CRF, KSV70CRF, KSV25HRF, KSV35HRF, KSV52HRF, KSV70HRF, KSV80HRF Refrigerant R32
Inverter Air Conditioner Installation Manual KSV25CRF, KSV35CRF, KSV70CRF, KSV25HRF, KSV35HRF, KSV52HRF, KSV70HRF, KSV80HRF Refrigerant R32 Congratulations Contents Congratulations and thank you for choosing
CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS
CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS (Refrigerant : R-407C) This unit is charged with new refrigerant, R-407C. Be sure to use proper tools for R-407C, when installing the unit.
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
AIR CONDITIONER INSTALLATION MANUAL
INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0
Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view
AIR CONDITIONER INSTALLATION MANUAL
FRANCAIS ESPAÑOL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring
ACDC12 Solar Air Conditioner Heat Pump
ACDC12 Solar Air Conditioner Heat Pump Model ACDC12 Solar Heating & Cooling Heat Pump Mini-Split System Installation Manual Before installing or using your solar air conditioner, please print and read
Room Air Conditioners
Installation Manual Room Air Conditioners R410A Split Type Y Series DC INVERTER ECO940SD ECO1240SD ECO1840SD Please read this installation manual completely before installing the product. When the power
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
Power supply unit Model: PAC-SC50KUA
Building Air Conditioning Control System Power supply unit Model: PAC-SC50KUA Installation Manual Contents 1. Safety precautions... 1 2. Product feature... 2 1. Specification... 2 2. Appearance... 2 3.
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION
ENGLISH REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION INSTALLATION GUIDELINES For International Prostar ISO 9001:2000 L 2647 Rev. 20090130 WARNING: Only trained technicians should perform
Installation Instructions
Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
INSTALLATION INSTRUCTIONS SINGLE SPLIT WALL MOUNTED AIR CONDITIONER
INSTLLTION INSTRUCTIONS SINGLE SPLIT WLL MOUNTED IR CONDITIONER Please read this instruction sheet completely before installing the product. When the power cord is damaged, replacement work shall be performed
OPTIONAL SLENDER REMOTE CONTROL
DAIKIN ROOM AIR CONDITIONER Operation Manual OPTIONAL SLENDER REMOTE CONTROL BRC944A2B READ BEFORE OPERATION Safety Precautions...2 Names of Functions of Parts...4 Preparation before Operation...5 OPERATION
DIGITAL SCROLL CENTRAL AIR CONDITIONER (OUTDOOR UNIT)
E-II-YDS-100-140-0907 ENGLISH INSTALLATION MANUAL DIGITAL SCROLL CENTRAL AIR CONDITIONER (OUTDOOR UNIT) YDS System, R410A, R407C & R22 / YDMH-C (B/A) 100&140 For correct installation, read this manual
9ASNA-A1-1202 SERVICE MANUAL SENVILLE AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE
9ASNA-A1-1202 SERVICE MANUAL SENVILLE AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function... 6 3. Dimension... 9 3.1 Indoor
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
TRS 090/105 Compressor. Repair Procedures
TRS 090/105 Compressor Repair Procedures GENERAL FGG All repair and service operations should be performed on a clean bench and with the use of clean tools. Use genuine parts and correct tools for all
Installation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE
Order No. MAC0512111C8 Air Conditioner CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE TABLE OF CONTENTS PAGE 1 Safety Precautions----------------------------------------------- 3 2 Specifications -----------------------------------------------------
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI Page 2 / 16 CONTENTS 1 GENERAL... 3 2 SAFETY... 3 2.1 Safety instructions... 3 2.2 Correct use... 3 3 DESCRIPTION
WALL MOUNTED SPLIT TYPE AIR CONDITIONER (J Series)
INSTALLATION MANUAL WALL MOUNTED SPLIT TYPE AIR CONDITIONER (J Series) INSTALLATION MANUAL IM-WMJ-1208(0)L-YORK Part No.: R08019032669 OUTLINE AND DIMENSIONS Indoor Unit [WMJ Series] THE MARK SHOWS PIPING
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Quest 105, Dry155, and 205 Dual
Quest 105, Dry155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.
SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL
SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL Thank you for choosing our Air Conditioner. Please read this OWNER'S MANUAL carefully prior to use and keep it for further reference. CONTENTS Contents
AIR CONDITIONER OUTDOOR UNIT
AIR CONDITIONER OUTDOOR UNIT INSTALLATION MANUAL For authorized personnel only. MANUEL D'INSTALLATION Pour le personnel agréé uniquement. English Français MANUAL DE INSTALACIÓN Solo para personal autorizado.
5800 Temperature Sensor Cable Assembly
5800 Temperature Sensor Cable Assembly Removal and Replacement Instruction Sheet #60-4702-070 Revision D, January 14, 2013 Overview The 5800 has two refrigeration temperature sensors, one attached to the
Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2
Warranty Registration: register online today for a chance to win a FREE Tripp Lite product www.tripplite.com/warranty Owner s Manual SRCOOLK (0V, 60 Hz) SRXCOOLK (30V, 50 Hz) Portable Air Conditioning
Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split
Multi System 16 SEER, Inverter System 9,000 to 18,000 BTU/Hr Single Split 4MXW8-A 4TXM6-A March2013 42 Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate
PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167
PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION
Cooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3