1 10615/TRE BuyLine 9964 A new way to look at walls. TrendWall

2 Long Term Solutions for Facilities on the It s all here. Consider TrendWall your alternative to permanent walls. It s a movable wall system designed to be easy to order, install and reconfigure. For more than 30 years, TrendWall has been performing in a wide variety of applications. Call us with your unique needs. There s more. You can hang furniture system components on TrendWall. Plus, there are plenty of options with panels up to 16 feet high (in standard, curved and glazed models), and modular or hardwire electrical. Costs less over time. TrendWall costs less in comparison to the cost of drywall when you consider depreciation and change. As an office is rearranged, the same components can be reused even in different configurations without damage to ceilings, floors and other architectural elements. Saves time. On installation on reconfiguration. Installation involves fewer trades and is completed in just a few simple steps. Building permits are not required when installing TrendWall, because it is classified as a wall system. Refer to Trendway s TrendWall Planning and Specifier Guide. Great acoustics. TrendWall with the sound packing option carries excellent acoustic ratings, making it an ideal solution for private office areas. For more technical information, refer to Trendway s TrendWall Acoustical Guide. Environmentally better. TrendWall can be used again and again as office needs grow and change. Unlike drywall, requiring demolition and special handling in disposal, TrendWall is environmentally sustainable. Find your TrendWall rep at 2

3 Move: TrendWall 10615/TRE BuyLine 9964 Pay back at tax time Because TrendWall is a wall system, it classifies as tangible property and qualifies for the Modified Accelerated Recovery System (MACRS). This benefit adds up at tax time, allowing depreciation over a seven-year period verses the thirty-nine year period that applies to conventional drywall construction. Churn rates make a difference With the national average for churn rates averaging at more than 23 percent, companies are eager to find new ways to organize office spaces. TrendWall pays off where the churn rate is 20 percent or higher. Movable walls are classified as tangible property Quick, easy planning and ordering TrendWall quotes and drawings are provided from the factory through authorized distributors within five working days. Once your prints are approved and order placed, TrendWall products ship within five weeks. Installation doesn t require building permits or cutting of carpets. Ease of installation Working from Trendway blueprints, installers attach crown pieces to the ceilings. Then floor plates are located and secured (this simple procedure requires no cutting of carpet or flooring). Next the panels are set in place and connected with panel connectors. After electrical and communications systems have been installed, pilasters with the same wall finish are snapped into place, finishing the vertical channels between the panels and completing the look. Return on investment gets better year after year ROI is based on the following: 1,000 feet of 8 feet vinyl-finished partitions 8% cost of capital 36% Federal tax rate 23.8% office churn TrendWall pays in the long run You will notice an increasing return on your investment after just three years of using TrendWall. Cash Flow TrendWall Drywall ROI $ 350,000 $ 300,000 $ 250,000 $ 200,000 $ 150,000 $ 100,000 $ 50,000 0 $ -50,000 Year 1 STC ratings of 36 and 40 exceed drywall Year 2 Year 3 Year 4 Year 5 Year 6 Year 7 Year 8 Year 9 Year 10 TrendWall with sound packing actually exceeds drywall construction s STC rating of 33. Refer to the chart at right for the relative speech privacy for TrendWall. adjoining area public areas open plan offices private offices privacy excellent excellent good 3

4 Performance Characteristics ISO9001 Certified Trendway is an ISO9001 certified manufacturer, so you can be assured of our quality standards. Fire ratings TrendWall has excellent fire ratings. Meets Class A requirements of NFPA 101 Life Safety Code: Flame Spread 0-25; smoke developed per ASTM-E84 Standard Test Method for Surface Burning Characteristics of Building Materials, similar to UI-723, ANSI No. 2.5, NFPA No. 255 and UBC Meets GSA requirements: Flame spread 0-25 and smoke developed 0-50 per ASTM-E84 Standard Test Method for Surface Burning Characteristics of Building Materials. Meets ULC requirements, Class I (A): Smoke Developed 0-25 per Canadian S102 Tunnel Test. Meets Canadian Government requirements per Class I (A) requirements of NFPA 101 Life Safety Code. Load-bearing statistics TrendWall s excellent load capabilities ensure a safe, durable office environment. TrendWall panels: Meet ANSI/BIFMA x requirements per Mechanical Strength Load tests: - Static Load Test, Work Surface Loading - Shelf Static Load Test, Multiple Shelf Loading Meet UBC and ICBO ES requirements per Traverse Load Test ASTM-E72; seismic related: - Single Panel Test - Three Panel System Test Acoustic ratings TrendWall s excellent acoustic ratings are comparable to site-built walls. The Sound Transmission Class rating (STC) ranges from 36 to 40 per ASTM-E90-90 and E With the options offered by TrendWall, you ll have everything you need to create a functional, attractive and reconfigurable office environment. Choose from great-looking fabrics and finishes; standard, curved, glazed and multiple glass panels; doors to meet different needs; and other options combine to create the look and function you want. With this kind of versatility, you can consider TrendWall an attractive alternative to permanent walls. Finish options Specify trim colors and surface treatments from a choice of standard and premium fabrics as well as textured and smooth vinyls and COM (customer s own material). Your Trendway representative can help you choose from our full selection of finishes. Glass There are five types of glazed panels: Hi Lite, Full Lite, Full Lite to Door Height, Window Lite and Multiple Glass. You will have to specify the types and locations of glazed panels. Doors Remember, there are three types of TrendWall doors and a variety of hardware options (unless specified otherwise, doors come standard with the ADA compliant lever latch). In addition, our doors feature glass and louver options. You must specify the types and location of the doors needed, and hardware options (such as lock sets or ADA lock). Customers also can use their own doors. An Exceptional Closets TrendWall enables you to create closets where you need them in your office environment. You will need to indicate the number and locations of Trendoor Closets required. Wall-hung components TrendWall can accommodate Choices2 and Contrada systems components, as well as components by other manufacturers. If wall-hung components will be used, Trendway needs to know the type and manufacturer of components and where the components will be located. Extra sound packing This is another option offered to TrendWall customers to allow for complete conversational privacy. TrendWall attains this by adding packing at the ceiling, base and pilasters. Find your TrendWall rep at 4

5 10615/TRE BuyLine 9964 Array of Options Improved productivity TrendWall is designed for productivity and efficiency. Floor-to-ceiling panels offer excellent acoustical properties in addition to a variety of aesthetics. TrendWall creates a comfortable atmosphere for private conferences or for work that demands focused concentration. From executive offices and conference rooms to supervisor offices within industrial environments, TrendWall enables you to create unique and movable spaces for different functions. Modular electrical systems A TrendWall office handles all communications and power cabling behind the scenes. Cutaways show TrendWall s ability to vertically and horizontally manage modular and hardwire electrical. Whichever type of electrical system you use, it will run through panel bases and pilasters to provide power access without being visible or under foot. There s no need to stretch cords from wall to desk; no more searching for outlets. TrendWall has designed work surface-height power outlets, making power and data cable management exceptionally convenient. Modular electrical Hardwire electrical 5

6 TrendWall Components There are eight basic components to a TrendWall installation: panels, doors, ceiling crowns, floor plates, panel connectors, modular electrical components, pilasters and bases. The two main TrendWall components are: Panels. TrendWall offers four types of panels: solid; glazed (Hi-Lite, Full Lite, Full Lite to Door Height, Window Lite and Multiple Glass); curved (to provide curves at 90-degree corners) and filler (placed at the end of a panel run that meets a fixed wall to compensate for uneven wall conditions or to interface with irregular shapes). Panels are fabric or vinyl clad 3 8" gypsum surface, available in a variety of fabrics, plus smooth or textured vinyls and COM (customer s own material). Panels can be specified with vinyl on one side and fabric on the other, an application that would be suitable, for instance, for an executive office that shares a wall with warehouse operations. Metal surfaces are finished with powder-coated epoxy. Painted surfaces are available in a variety of trim colors. For fabric and color options, ask your Trendway rep for the Surface Materials Color Legend. Panels have rolled-form metal steel frames: 18-gauge top and bottom rails; 19-gauge side rails; 22-gauge horizontal intermediate interior rails and a 4-pound density therma-fiber mineral wool core. To compensate for irregularities in a floor or ceiling, panels have a base that provides for adjustments 3 4" up and/or down. Panels are available in any height from 7' 2" to 12' and in any width from 6" to 4'. Unless the customer requests specific widths, the most cost-efficient is the 4'-wide panel. Ceiling filler panels can add 1' to 4' to a panel height. Ceiling filler blocks can add an additional 1" to 12" to a panel height. Crown Connector Straight Panel Connector Crown Filler Panel Wall Channel Glass Molding Glazed Panel Leveling Bolt Carpet Grippers Base Corner Doors. TrendWall offers three types of pre-hung doors. Each model complies with ADA door clearance requirements and comes standard equipped with an ADA compliant lever latch. They re vinyl faced, made of flush hollow core and solid core wood construction, are pre-hung in frames and include a steel jamb and transoms. Doors are non-reversible and come in standard vinyl and trim colors. Single doors are 3' wide by 6' 8" or 7' high by 1 3 4" thick. They must be specified left-hand or right-hand swing, and can be specified with or without windows and louvers. With double doors, one door is active and the other is inactive and held closed by a latch. Unlocking the latch allows both doors to open, providing a 6'-wide entrance. Bi-fold doors are double doors hinged in the middle to fold out of the way as they open. Used primarily with cloak rooms or storage closets. Other basic TrendWall components include: Ceiling Crowns. U-shaped ceiling channels hold each TrendWall panel in place. They re made of 18-gauge roll-formed steel. Floor Plates. These 20-gauge roll-formed steel channels are used to align and attach the base of a TrendWall panel to the floor. Panel Connectors. These connectors make straight and corner panel connections. They re 11-gauge steel. Extended and half-extended connectors are used with hang-on furniture. Electrical. TrendWall s modular electrical system provides duplex receptacles Crown Corner Corner Panel Connector Crown Alignment Plate Solid Panel Transom Block Ceiling Brace Stabilizer Bracket Door Section Pilaster Door Jamb Anchor where needed in the wall run. Electrical conduit can be routed through the horizontal base of TrendWall panels. It can also run up or down through the vertical connections between panels. Electrical outlets and switches are mounted in junction boxes to the conduit. Refer to the TrendWall Planning and Specification Guide for more details. Power Module TrendWall Harness Pilasters. Finished strips designed Vinyl Base to snap into place Corner Pilaster between panels conceal Floor Plate panel connectors and wiring. They come in the same height as panels and are available with optional punchouts for switches and duplex receptacles (unless otherwise specified, switches are located 45" up from the floor to the centerline; receptacle outlets are 14" and 32" from the floor). Bases. Like pilasters, bases are used to finish the look of a TrendWall office. Made of extruded vinyl, bases finish the bottom of the TrendWall panel. Find your TrendWall rep at 6

7 Guide Specifications PART 1 - GENERAL 1.01 SUMMARY A. This specification defines the TrendWall floor-to-ceiling panel system which is designed to provide enclosed office spaces in an open plan environment and the ability to modify or reconfigure office spaces to meet changing office requirements. The system shall consist of connecting structural panels with provisions for mounting furniture systems components and be fully integrateable and compatible with open plan office systems REFERENCES A. ANSI/BIFMA x , Mechanical Strength ASTM-E84, Surface Burning Characteristics of Building Materials ASTM-E90-90, Acoustical Sound Transmission Class ASTM-E72, Transverse Load CAN/ULC-S102-M88, Surface Burning Characteristics of Building Materials and Assemblies, Underwriters Laboratories of Canada Canadian Government Standards Board (CGSB) General Services Administration (GSA), United States Government International Conference of Building Officials, Evaluation Services (ICBO ES) International Organization for Standardization (ISO) National Fire Prevention Association (NFPA) Unified Building Code (UBC) 1.03 SYSTEM DESCRIPTION A. The specified system shall be for interior wall application, fully relocatable and non-progressive. The system shall consist of two major component sections: (1) Fully-assembled Panels include solid (fabric or vinyl covered), glazed or curved; and (2) Pre-hung Doors in frames include single, double or bi-fold options. The system s six other basic components shall be the Ceiling Crowns, Floor Plates, Connectors, Electrical, Pilasters and Bases. B. Design and Performance Requirements: 1. Fire Protection - The system s solid panel component shall meet fire protection requirements defined by NFPA 101 Life Safety Code - Class A, GSA, ULC and CGSB. 2. Load-Bearing - The system s solid panel unit shall meet ANSI/BIFMA mechanical strength load tests and UBC and ICBO ES requirements for transverse loads. 3. Acoustics - The system s solid panel unit shall produce a sound transmission classification rating of STC SUBMITTALS A. Upon receipt of customer s floor plan, including the needs of the office (hanging furniture components, etc.), Trendway shall create a computergenerated (CAD) floor plan of the desired TrendWall office for customer s approval. B. Upon approval of the TrendWall CAD drawing, the product shall be built to the exact approved specifications of the customer QUALITY ASSURANCE A. The specified TrendWall panel system shall be designed, developed, manufactured, inspected, tested, installed and serviced in accordance with ISO9001 Standards and the manufacturer shall be a registered ISO company. B. Sound Transmission: 1. Independent laboratory certification shall be available which certify that the standard solid TrendWall panels provide an STC rating of 36 in accordance with ASTM-E90-90 and E C. Fire Protection: 1. Independent laboratory certification shall be available which certify that the standard TrendWall fabric and vinyl covered panels meet the class A requirements of the NFPA 101 Life Safety Code with a flame spread maximum allowable of 25 and maximum smoke density allowable of Certification shall be available which verify that standard solid TrendWall fabric and vinyl covered panels meet GSA flame spread maximum requirements of 25 and smoke density maximum allowable of 50 per ASTM-E /TRE BuyLine Certification shall be available which verify that standard solid TrendWall panels with specific fabric and vinyl coverings meet ULC flame spread maximum requirements of 25 for office wall panel applications and 150 for corridor usage per CAN/ULC-S102-M88 in compliance with requirements of the National Building Code of Canada. 4. Certification shall be available which verify that standard solid TrendWall fabric and vinyl covered panels meet Canadian Government requirements consistent with class A requirements of the NFPA 101 Life Safety Code with maximum flame spread allowable of 25 and maximum smoke density allowable of 450 per ASTM-E84. D. Structural: 1. Independent laboratory certification shall be available which certify that standard solid TrendWall panels meet load-bearing capacity for hanging components of not less than 7 pounds per lineal inch when tested in accordance with ANSI/BIFMA x Certification shall be available which verify that the TrendWall panel system meets City of Los Angeles, Department of Building and Safety, product approval in accordance with UBC and ICBO ES related regulations DELIVERY, STORAGE AND HANDLING A. Packing, Shipping, Handling and Unloading: 1. TrendWall products shall be shipped uncrated, blanket wrapped whenever possible. If only cartoned shipments are acceptable, this information must be indicated on each purchase order and a carton charge will be added. 2. All orders shipped to any destination within the contiguous United States, shall be F.O.B. origin, freight prepaid and risk of loss or damage shall pass to Buyer upon delivery to carrier. Trendway shall determine the method and agency of transportation to be used. 3. Customer-directed or expedited shipments (Air Freight, Federal Express, etc.) shall be prepaid and billed at actual cost. 4. An order is defined as each purchase order issued with a single shipped to address without special marking or tagging. B. Acceptance at Site: 1. In the event that special F.O.B. destination terms are agreed to by Trendway or delivery is made on Trendway owned or leased equipment, customer or authorized representative is responsible for noting any freight damage or shortage on the freight bill of lading at time of delivery and must notify Trendway within five (5) days of delivery day of any such damage or shortage. 2. Assistance in a concealed damage claim on an F.O.B. destination shipment will be provided by Trendway only if the product has been immediately unpacked and both the carrier and Trendway have been promptly notified of resultant damage so the proper inspection can be made. C. Storage and Protection: 1. When shipment is delayed by the buyer, Trendway reserves the right to place the goods in storage at customer s risk and cost. 2. All terms and conditions of the sale including but not limited to invoicing and payment, will continue as if the product had been shipped to a Buyer specified destination; except that title remains with Trendway and that Trendway reserves the right to modify payment terms to assure recovery of any additional cost incurred PROJECT/SITE CONDITIONS A. Environmental Requirements and Existing Conditions: 1. Guided by specific steps indicated in the TrendWall Planning and Specification Guide Order and Planning section, note specific environmental and/or site conditions cited under the following topic headings which are vital in producing an accurate layout and specification for appropriate TrendWall product: a. Inspect The Site d. Electrical Planning b. Measurements Are Key e. The Finishing Touches c. Begin Your Office Layout 1.08 SEQUENCING AND SCHEDULING A. For Installation Sequencing and Scheduling, refer to the Trendway Installation Guide for TrendWall Floor-To-Ceiling Panels or contact Trendway Customer Service. 7

8 1.09 WARRANTY A. For complete Warranty description, contact Trendway Customer Service MAINTENANCE A. For proper maintenance of Trendway products, contact Trendway Customer Service for appropriate literature and/or instructions. PART 2 - PRODUCTS 2.01 MANUFACTURER A. TrendWall movable floor-to-ceiling wall system is manufactured by Trendway Corporation, Holland, Michigan MATERIALS A. Framing: 1. TrendWall panels shall be fabric or vinyl clad, available in a wide variety of fabrics, plus smooth or textured vinyls and COM (customer s own material) and can be specified with vinyl on one side and fabric on the other. 2. Panels shall be 2 3 4" thick and have a 2 3 4" x minimum space between panels for electrical and communication mounting, and a 2 3 4" x 3" space in the base to provide for distribution of electrical and communication routing for continuous lay-in of wiring and cables. 3. Panels shall be available in any height from 7'2" to 12'. Ceiling filler panels shall add an additional 1' to 4' to a panel (the minimum ceiling filler panel is 1'). Ceiling filler blocks shall add an additional 1" to 12" to a panel height (cannot be used with a ceiling filler panel). 4. Panels shall be available in any width from 6" to 4'. 5. To compensate for irregularities in a floor or ceiling, panels shall have an adjustable base that provides for adjustments 3 4" up and/or down. 6. Ceiling crowns shall be 18-gauge roll-formed steel U-shaped channels that hold each TrendWall panel in place. 7. Floor plates shall be 20-gauge roll-formed steel channels used to align and attach base of panels to floor. 8. Panel connectors shall be 11-gauge steel and used to connect panels to one another. 9. Pilasters shall be finished strips of 22-gauge rolled-formed steel and/or.06 thick rigid PVC with snap in place design, in fabric or vinyl coverings and conceal the connectors and wiring between panels. An optional monolithic (enhanced) design shall also be available. See TrendWall Planning & Specification Guide and/or contact Trendway Customer Service for additional information. 10. Vinyl bases shall be provided to finish off the TrendWall panel system bottom area. B. Solid Panels-Regular: 1. Shall have rolled-formed steel frames with 18-gauge top and bottom rails, 19-gauge side rails, 22-gauge horizontal intermediate interior rails. 2. Shall be 4 pound density therma-fiber mineral wool core. 3. Shall be 3 8" gypsum face sheets. C. Glazed Panels: 1. Shall be insertable glass frames of 22-gauge steel vertical and horizontal rails, durometer vinyl glass retainers for 1 4" glass. Glass to be by others, safety glass is recommended. a. Optional Glazed Designs: - Hi Lite (glazed look through) - Full Lite (entire panel glazed) - Full Lite to Door Height (glazed up to height of top of door) - Window Lite (glazed from 42" from floor to top of door) - Multiple Glass D. Curved Panels: 1. Shall be wood framed with honeycomb core and 19-gauge steel side rails to provide 90 degree corners. Optional glazed designs also available. E. Filler Panels: 1. Construction shall be steel supported one end, 8 pound density styrofoam core and gypsum faces and design which allows for uneven adjacent fixed wall conditions or irregular shapes. F. Doors: 1. Three types of doors shall be available which comply with ADA door clearance and door handle hardware requirements: a. Standard Single Doors - 3' wide by 6' 8" or 7' high by 1 3 4" thick with or without windows. Standard door sections are a nominal 4'. b. Double Doors - provide a 6' wide entrance c. Bi-Fold Doors - for cloak rooms or storage closets G. Electrical: 1. The TrendWall panel system shall provide optional ways of accessing building power and provide electrical power where needed. Such optional component means include: a. Power Feeds: Ceiling Feed, End Mount Base Feed, Base Feed Hardwire b. Pass Through Harnesses c. Male/Male Harnesses d. Power Modules e. Work Height Adders f. Switch Patch 2. Refer to the TrendWall Planning & Specification Guide and/or contact Trendway Customer Service for additional detailed information COMPONENTS A. Component Mounting Options: 1. The TrendWall panel system shall have a means of mounting both Trendway and non-trendway office systems components. Refer to the TrendWall Planning & Specification Guide and/or contact Trendway Customer Service for detailed information FINISHES A. Steel Frame: 1. All metal surfaces shall be finished in powder-coated epoxy and offered in a variety of trim colors. B. Vinyl Trim: 1. Parts shall be available in molded-in standard TrendWall colors. PART 3 - EXECUTION 3.01 EXAMINATION/INSPECTION A. Before installing the TrendWall panel system, a re-inspection of the installation site shall be made by the contractor to re-verify vital information used to specify the initial product required, such as ceiling height, floor conditions and other physical characteristics that can affect an installation INSTALLATION A. Five basic steps comprise the TrendWall installation process: 1. Ceiling Crown 4. Glazing and Electrical 2. Floor Plate 5. Trim 3. Panels B. For a detailed description of each process step, refer to the the TrendWall Planning & Specification Guide or contact Trendway Customer Service Supplemental information on the following subject areas is also available through Trendway Customer Service. A. REPAIR/RESTORATION C. ADJUSTING B. RE-INSTALLATION D. CLEANING For additional specifications and technical information, contact your local Trendway representative or Trendway Customer Service. For Further Information, Contact Trendway or Call Sweet s BuyLine Trendway Corporation P.O. Box 9016 Holland, MI Customer Service: FAX: Web Site:

Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art

Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art D O O R F R A M E S Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art D O O R F R A M E S Eggers Industries

More information

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401 BASIC FIRE DOOR REQUIREMENTS SHEET NO. 401 Fire door openings are classified by their locations in the building. The location determines the length of exposure protection required, based on the potential

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery Alpha System ADAPTABLE LABORATORY FURNITURE KEWAUNEE encouraging new discovery Alpha 6 partition modules with Kemresin worktops. Minneapolis, Minnesota Alpha 6 partition modules with Alpha overhead service

More information

CLEAR-DIVISIONS APERTO

CLEAR-DIVISIONS APERTO CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the

More information

glass & Glazing Products

glass & Glazing Products glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system

More information

Automatic Door Selection Guide

Automatic Door Selection Guide Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 aaadm@aaadm.com Automatic Door Selection Guide General: The members of AAADM manufacture an assortment

More information

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME) SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME) Construction Criteria The unit costs for ADP Mainframe space types are based on the construction quality and design features in the following

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

CLEAR-DIVISIONS VARIOFOLD

CLEAR-DIVISIONS VARIOFOLD CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for premium composite, hollow and solid core molded Bifold Doors. Bifolds are designed for fast

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-87 8d METAL DOORS & FRAMES NAAMM 2 87 HOLLOW METAL HOLLOW METAL DOORS FOURTH EDITION NAAMM 2 87 8d METAL DOORS & FRAMES A Division of NATIONAL ASSOCIATION OF

More information

ATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS

ATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS ATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS 1.0 GENERAL INFORMATION Structural Interior Design includes all building related elements and components generally part of the building itself,

More information

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

WHI 90-Minute Rated Veneered Door Frame Installation Instructions No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,

More information

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman.

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman. Building Type Building Code Whitley Classroom Buildings BOCA, UBC, SBCCI, NEC, ADA Structural Support Outrigger construction standard, Whitley model classrooms. Main support beams to be 12 11.8# per lineal

More information

How to Estimate the Cost of Interior Building Finishes from Schematic Drawings. CPE Candidate No. 0714108. December 2014

How to Estimate the Cost of Interior Building Finishes from Schematic Drawings. CPE Candidate No. 0714108. December 2014 How to Estimate the Cost of Interior Building Finishes from Schematic Drawings CPE Candidate No. 0714108 December 2014 1 How to Estimate the Cost of Interior Building Finishes from Schematic Drawings Table

More information

MBA Design & Display Products Corp. Mila-wall Movable Wall Panels

MBA Design & Display Products Corp. Mila-wall Movable Wall Panels MBA Design & Display Products Corp. Mila-wall Movable Wall Panels 02 Mila-wall Series 100 As easy as.. Free Standing Paintable Nailable Stackable Seamless Appearance Easy to Store The Technique 03 The

More information

SERIES 642F SPECIFICATIONS

SERIES 642F SPECIFICATIONS SERIES 642F SPECIFICATIONS Firewall Paired Panels PRODUCT OVERVIEW: One Hour Fire Rated Top Supported Center Stack Paired Panels Manually Operated Maximum Opening Height: 24 2 [7.366] Maximum Opening Width:

More information

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system

More information

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Built to Last. Built for Beauty. Good. Solid. Logix. TM Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a

More information

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version CEILING SYSTEMS Between us, ideas become reality Installing Suspended Ceilings North America Version 1 Installing Armstrong Suspended Ceilings An Armstrong suspended mineral fiber ceiling is functional,

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE The University of Arizona has implemented a Keyless Access and Security System program to provide a cost effective, efficient, and maintainable means

More information

One of the most important parts of our business, is protecting yours. Here s how.

One of the most important parts of our business, is protecting yours. Here s how. Jarke Steel Sentry Protective Rail Systems One of the most important parts of our business, is protecting yours. Here s how. A busy warehouse, plant, or distribution center can pose a real challenge when

More information

Secure your IT equipment with confidence... secure with NetClosure

Secure your IT equipment with confidence... secure with NetClosure Secure your IT equipment with confidence... secure with NetClosure SERVER CABINETS NetClosure s REM Series Server Cabinet is the ultimate solution designed and engineered for demanding data center environments.

More information

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001 Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

Base Cabinet with Self-storing Folding Doors and Floor

Base Cabinet with Self-storing Folding Doors and Floor Usable Kitchens When designing a kitchen for use by persons with mobility impairments, especially those who use wheelchairs, careful layout of the kitchen is crucial to maintaining accessibility. People

More information

FIRESTOPPING & SMOKE SEALS

FIRESTOPPING & SMOKE SEALS SPECIFICATION SECTION 07 84 00 FIRESTOPPING & SMOKE SEALS 1 GENERAL 1.1 SECTION INCLUDES 1.1.1 Comply with Division 1, General Requirements and Documents referred to therein. 1.1.2 It is the intent of

More information

PRO PANELS. 1-800-525-4159 www.propanels.com. the artist s choice in display designed by artists, for artists. voice: 214-350-5765 fax: 214-350-7372

PRO PANELS. 1-800-525-4159 www.propanels.com. the artist s choice in display designed by artists, for artists. voice: 214-350-5765 fax: 214-350-7372 PRO PANELS by MD Enterprises the artist s choice in display designed by artists, for artists 1-800-525-4159 www.propanels.com voice: 214-350-5765 fax: 214-350-7372 MD Enterprises 1-800-525-4159 voice:

More information

C. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction.

C. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction. SECTION 081216 - INTERIOR ALUMINUM DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such

More information

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including general and supplementary conditions and other Division 1

More information

A Complete Solution CREATING WALLS THAT DEFINE SPACE

A Complete Solution CREATING WALLS THAT DEFINE SPACE A Complete Solution CREATING WALLS THAT DEFINE SPACE COMPANY HISTORY CLIPPER WALL Clipper partitions are part of the Saint- Gobain Group, one of the worldwide leaders in the construction products industry.

More information

Technical Data Honeycomb Door Leaf 8-1-99

Technical Data Honeycomb Door Leaf 8-1-99 8--99 8-/8 8-7/8 B 8-/4 A A Dim. A Leaf Width B ELEVATION F DESIGN Vertical edge seams mechanically interlocked Square hinge and lock edges 4-/ x.4 full mortise hinge prep Gov. 60/6 cyl lock prep...prefix

More information

DE Frame with C Series Sidelight

DE Frame with C Series Sidelight TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder

More information

How To Power A Power Supply On A Powerline From A Power Source To A Power Box

How To Power A Power Supply On A Powerline From A Power Source To A Power Box Power Base AI Power Base AI Application Guide Table of Contents Product Overview Our Philosophy On Electrical... 4 System Overview... 5 Power Base AI Statement of Line.... 6 Power Base AI Components...

More information

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications INC Flexi-Sorb Noise Control Curtain System Versatile Flexible Easy To Install Durable Good Noise Reduction Economical Our Flexi-Sorb noise control curtain product line consists of flexible, durable acoustical

More information

H-Stud Area Separation Wall System

H-Stud Area Separation Wall System 12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic

More information

Turning nature s beauty into works of art

Turning nature s beauty into works of art f l u s h d o o r s Eggers 5-ply flush doors are the very embodiment of form marrying function - extraordinary beauty and exceptional durability. We are able to produce a variety of custom architectural

More information

INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS

INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS 1. Paragraph 1.02 Provide solid surface countertops at sinks locations. Provide solid surface window sills at drywall framing walls.

More information

LEASE BETWEEN RALEIGH PORTFOLIO JH RETAIL, LLC AND CITY OF DURHAM FOR SPACE IN THE BUILDING AT 2945 S. MIAMI BOULEVARD; DURHAM, NC EXHIBIT A

LEASE BETWEEN RALEIGH PORTFOLIO JH RETAIL, LLC AND CITY OF DURHAM FOR SPACE IN THE BUILDING AT 2945 S. MIAMI BOULEVARD; DURHAM, NC EXHIBIT A EXHIBIT A SCOPE OF WORK TO BE COMPLETED BY LANDLORD FOR THE DISTRICT 4 POLICE SUBSTATION AT 2945 S. Miami Boulevard, SUITES 133,134,135, and 136 Dated August 21, 2012 All work must be done in compliance

More information

electrics P OW E R E N T RY B A S I C S P OW E R & C O M M U N I C AT I O N S B A S I C S P OW E R D I S T R I B U T I O N B A S I C S

electrics P OW E R E N T RY B A S I C S P OW E R & C O M M U N I C AT I O N S B A S I C S P OW E R D I S T R I B U T I O N B A S I C S P RO D U C T M A P / TA B L E O F C O N T E N T S..................6 8 6 E L E C T R I C S & C O M M U N I C AT I O N S O V E RV I E W.............6 8 9 P OW E R E N T RY B A S I C S PA N E L - M O U N

More information

9300BC SERIES Light Commercial Door Closer

9300BC SERIES Light Commercial Door Closer Light Commercial Door Closer general information The 9300BC is a durable, economically priced door closer designed for commercial exterior and interior doors such as storefront and industrial applications.

More information

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE The University of Arizona has implemented a Keyless Access and Security System program to provide a cost effective, efficient, and maintainable means

More information

Guidelines for Earthquake Bracing of Residential Water Heaters

Guidelines for Earthquake Bracing of Residential Water Heaters Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)

More information

Guidelines for Earthquake Bracing Residential Water Heaters

Guidelines for Earthquake Bracing Residential Water Heaters Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the

More information

SECTION 6. Glass Storefront Doors:

SECTION 6. Glass Storefront Doors: SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail

More information

AirBlock Data Center Doors

AirBlock Data Center Doors Data Center Doors AirBlock Data Center Doors What makes AirBlock the best? Works with your existing hot aisle/cold aisle isolation system. Doors accommodate different racks within the same data center;

More information

Basic Fire Door Requirements

Basic Fire Door Requirements TECHNICAL DATA SERIES S D I 118-01 Basic Fire Door Requirements 2001 Steel Door Institute STEEL DOOR INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 Technical Data Series SDI 118-2001 Basic Fire Door

More information

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide

More information

Model # 940P-V6. Page 1 of 11

Model # 940P-V6. Page 1 of 11 Model # 940P-V6 Page 1 of 11 Page 2 of 11 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic coated elements. Ultra Play guarantees all items for one full year to be free of defects in

More information

Utility Distribution Systems

Utility Distribution Systems Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date

More information

Tate s Wire & Cable Solution

Tate s Wire & Cable Solution Access Floors Tate s Wire & Cable Solution A Flexible & Sustainable Management System Access Flooring to the Power of Your company will discover complete flexibility and reconfiguration capability 2 Creating

More information

Storage Solutions. Maximize Storage & Optimize Space

Storage Solutions. Maximize Storage & Optimize Space Storage Solutions Maximize Storage & Optimize Space Your Files Are Important With the cost and availability of office space at a premium, space utilization is key. An end-tab color-coded filing system

More information

Phoenix-3W Series One-Way Security Revolving Doors

Phoenix-3W Series One-Way Security Revolving Doors Phoenix-3W Series One-Way Security Revolving Doors ONE-WAY SECURITY REVOLVING DOOR SPECIFICATIONS ARCHITECTURAL SPECIFICATIONS Phoenix-3W Series One-Way Security Revolving Door Division 8 Doors and Windows

More information

City of San Diego, CWP Guidelines

City of San Diego, CWP Guidelines PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,

More information

SECTION 28 05 00 COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY

SECTION 28 05 00 COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY SECTION 28 05 00 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specifications Sections, apply

More information

IBC Tote Containment Sumps

IBC Tote Containment Sumps IBC Tote Containment Sumps DENIOS Provides More Models- and More Variety of IBC Totes Sumps than any other Manufacturer Painted, Galvanized, Stainless Steel, and Poly models available Models provide storage

More information

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

WINDOW AND DOOR REPLACEMENT REQUIREMENTS WINDOW AND DOOR REPLACEMENT REQUIREMENTS Should you have any questions after reading the following information, please call the Building Inspection Department at 651-439-4439 to discuss the topics of concern.

More information

DIGITUS Network & Server Cabinets. UNIQUE Series

DIGITUS Network & Server Cabinets. UNIQUE Series DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door

More information

AirBlock Data Center Doors

AirBlock Data Center Doors Data Center Doors AirBlock Data Center Doors What makes AirBlock the best? Works with your existing hot aisle/cold aisle isolation system. Doors accommodate different racks within the same data center;

More information

Electrical Wiring Technical Bulletin

Electrical Wiring Technical Bulletin Electrical Wiring Technical Bulletin Overview In general, SIP construction is easier and more cost effective when things are planned and thought out before the panels are manufactured. This process will

More information

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide

More information

Fiberglas, Exterior Wall Thermal Insulation

Fiberglas, Exterior Wall Thermal Insulation PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF)

SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF) SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF) PART 1-GENERAL 1.01 RELATED WORK SPECIFIED IN OTHER SECTIONS A. Electrical connections see electrical specifications. 1.02 SUBMITTALS A.

More information

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6 050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY

More information

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11 K. D. FRAME ASSEMBLY FOR MASONRY WALLS...........................Ins 2 FRAME INSTALLATION DETAILS FOR MASONRY WALLS......................Ins 3 INSTALLING EXISTING MASONRY WALL ANCHORS IN FRAME..................Ins

More information

Enhancing The Beauty And Value Of Your Home. Exclusive Patio Door Collection. NORTH STAR PATIO DOOR COLLECTION Two-Panel Three-Panel Four-Panel

Enhancing The Beauty And Value Of Your Home. Exclusive Patio Door Collection. NORTH STAR PATIO DOOR COLLECTION Two-Panel Three-Panel Four-Panel Enhancing The Beauty And Value Of Your Home. Exclusive Patio Door Collection. NORTH STAR PATIO DOOR COLLECTION Two-Panel Three-Panel Four-Panel Since 1985 North Star has been an industry leader in the

More information

PROJECT WORKPLACE DEVELOPMENT

PROJECT WORKPLACE DEVELOPMENT CISCO PROJECT WORKPLACE DEVELOPMENT New York Room Basic Meeting Room Integration Price $15,000.00 Annual Service Contract $2,250.00 Zdi is the valued Cisco partner that integrates this room s technology

More information

Product Guide Specification

Product Guide Specification Stabilit America, Inc., dba Glasteel June 2005 285 Industrial Drive Moscow, Tennessee 38057 Toll Free (800) 238-5546 Phone (901) 877-3010 Fax (901) 877-1388 Web Site www.glasteel.com Product Guide Specification

More information

Pyroguard Wired Glass

Pyroguard Wired Glass Fire-rated Glass Pyroguard Wired Glass Where glass becomes architecture Section 15 03 Introduction Oldcastle Glass stocks nonwired Pyroguard laminated safety glass and polished wired glass for commercial,

More information

MGB Chrome Bumper Conversion

MGB Chrome Bumper Conversion MGB Chrome Bumper Conversion Installation Instructions For 1974 1/2-1980 MGB This kit requires cutting, welding, and painting. Professional installation recommended. Note: Every MGB body is slightly different

More information

screens U N D E R S TA N D I N G S C R E E N S...9 0 PA N E L WA L L A D D - O N S C R E E N B A S I C S...9 3

screens U N D E R S TA N D I N G S C R E E N S...9 0 PA N E L WA L L A D D - O N S C R E E N B A S I C S...9 3 U N D E R S TA N D I N G S C R E E N S...........................9 0 PA N E L WA L L A D D - O N S C R E E N B A S I C S...................9 3 P L A N N I N G W I T H A D D - O N S C R E E N S.....................9

More information

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY Construction Criteria The unit costs for (Wet) space types are based on the construction quality and design features in the following table. This

More information

White Paper FIRE DOOR INSPECTIONS, REPAIRS AND LABELING

White Paper FIRE DOOR INSPECTIONS, REPAIRS AND LABELING INTRODUCTION When the 2012 edition of the Life Safety Code is adopted by the Centers for Medicare Services (CMS) the following accreditation organizations The Joint Commission, AOA Healthcare Facilities

More information

SAME JETC May 22-25, 2012. St. Louis, Missouri IMPORTANT

SAME JETC May 22-25, 2012. St. Louis, Missouri IMPORTANT 18a Electrical Terms and Conditions IMPORTANT Please read the list of work below. If you require any of this work to be performed in your booth space, it must be performed by a show electrician. This work

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION 17650 SECURITY SYSTEMS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION 17650 SECURITY SYSTEMS PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Inspections and observations by the Owner do not relieve the A/E of contract responsibilities. B. Chain of command 1. The DPS Project Manager is

More information

Quality Building Products for over 50 Years

Quality Building Products for over 50 Years Light Commercial Quality Building Products for over 50 Years Harvey Building Products is a leading manufacturer and distributor of high quality building products. We manufacture a complete line of superior

More information

Single Family Residential Basement Finish

Single Family Residential Basement Finish How to Use This Guide Building Guide Pottawattamie County Planning & Development Department Building & Safety Division Single Family Residential Basement Finish Provide two (2) sets of plans and complete

More information

PUBLIC RESTROOMS, DESIGN INTENT

PUBLIC RESTROOMS, DESIGN INTENT PUBLIC RESTROOMS, DESIGN INTENT 1.01 STRUCTURAL A. Where feasible, metal stud partitions will be constructed on a 6 high concrete curb. 1.02 MECHANICAL A. Restrooms will have a minimum of 15 air changes

More information

Steel Door Institute. Fire Rated Doors and Frames

Steel Door Institute. Fire Rated Doors and Frames Steel Door Institute Fire Rated Doors and Frames 1 1. Nomenclature and Overview 2. Fire Rated Frames 3. SDI 118 4. Fire Rated Doors 5. Fire Rated Hardware 6. Specialty Products Table of Contents 2 Fire

More information

Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions

Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions Y Parts Included: Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions Tools Required: Power Driver Drill Bit (Determined by fastener) Driver Bit (Determined by fastener)

More information

SECTION 807 PUMP STATION REHABILITATION

SECTION 807 PUMP STATION REHABILITATION SECTION 807 PUMP STATION REHABILITATION 807-1 DESCRIPTION: Rehabilitation of pump stations shall be defined as the cleaning, removal, repair and/or replacement of any and/or all components including but

More information

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein

More information

INTERIOR CONCEPTS Contact Center

INTERIOR CONCEPTS Contact Center INTERIOR CONCEPTS Contact Center For once, less really is more. Our innovative panel system takes up less room and allows you to move fluidly within your space. By working around the existing architecture,

More information

This directive establishes Department of Homeland Security (DHS) policy regarding the physical protection of facilities and real property.

This directive establishes Department of Homeland Security (DHS) policy regarding the physical protection of facilities and real property. Department of Homeland Security Management Directives System MD Number: 11030.1 Issue Date: 04/21/2003 PHYSICAL PROTECTION OF FACILITIES AND REAL PROPERTY I. Purpose This directive establishes Department

More information

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11 Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU

More information

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders

More information

Packaged Terminal Air Conditioner Wall Sleeve Installation

Packaged Terminal Air Conditioner Wall Sleeve Installation Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

Specifications, Product Testing and Terminology

Specifications, Product Testing and Terminology Specifications, Product Testing and Terminology The following synopsis provides a review of various material and final product testing, which is performed on our products, as well as, many of our competitors.

More information

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS International Code Council National Fire Protection Association Underwriters Laboratories Inc. 5203 Leesburg Pike, Suite 600 1 Batterymarch

More information

DCF Optimized Rack System

DCF Optimized Rack System Integrated Cabinet Solutions For Business-Critical Continuity DCF Optimized Rack System User Manual IMPORTANT SAFETY GUIDELINES SAVE THESE INSTRUCTIONS This manual contains important instructions that

More information

Solar Panel Installations

Solar Panel Installations Solar Panel Installations Page 1 of 6 SINGLE-FAMILY RESIDENTIAL CHECKLIST City of Hayward Development Services Department Revised: 7-09-15 PERMIT REQUIREMENTS Permits are required for all solar panel installations.

More information