JAN
|
|
- Rebecca Elliott
- 8 years ago
- Views:
Transcription
1 JAN 2013 MANUFACTURED IN THE UK BRITISH MADE INSTACLAVES FOR 40YRS
2 Water Purification Reverse Osmosis Water Filtration System TDS Meter Monitors the total dissolved solids content of the supply and filtered water 4 Stage Filtration System Wall mounted, supplied with all necessary hoses, fittings. Water Storage Tank Kit 2.2 US Gallon capacity, includes auto shut off valve and chrome worktop faucet Ideal water for your autoclave / washer disinfector Purified water on demand No storage of bulky containers Mount it anywhere Simple to install Removes up to 99.8% of all dissolved solids Offer VAT
3 How it works 1 Water Purification The first stage of filtration is the sediment filter, which reduces suspended particles such as dirt, dust and rust The second stage of filtration is the carbon filter which reduces volatile organic chemicals, chlorine, and other taste and odour causing compounds. Chlorine is damaging to an RO membrane therefore the carbon stage is particularly important 3 The heart of Reverse Osmosis is the membrane. It is responsible for rejecting up to 99% of the total dissolved solids in the water. This is where the purification takes place. 4 A de-ionisation cartridge is included in your Reverse Osmosis system, our cartridges use semi-conductor mixed bed de-ionisation resins used for the de-mineralisation of aqueous solutions. STOCK CODE DESCRIPTION PRICE +VAT Stage 75 GPD R/O System Gallon Water Storage Kit Gallon Water Tank TDS In-line Digital Meter Self Regulating Booster Pump Kit CONSUMABLES * Recommended replacement period 6 months ** Recommended replacement period 3 years STOCK CODE DESCRIPTION PRICE +VAT De-ionising resin 1 litre* Carbon Filter Element* Sediment Filter element* R/O 75 GPD Filter Element** 44.95
4 Washer Disinfector Burtons Instawash Dental Washer Disinfector NEW Fully compliant to EN15883 HTM2030 Instawash 1000 Offer 1995 RRP cm W x 48cm D x 47cm H Optional traceability printer and/or datalogger available 1-touch fully automatic operation Operation of the Instawash couldn t be simpler. Just the touch of a button starts the process, which is then fully repeatable. (Complies to HTM 20/30 & EN15883) RO (reverse osmosis) connection as standard The machine has the facility to connect directly to your RO supply if available. See our great offers on RO systems on page 2 & 3. Instawash 3000 Offer 2995 RRP cm W x 59cm D x 85cm H The fully equipped Burtons Instawash has been designed specifically to protect dental hand pieces and instruments. The Instawash uses specially formulated enzymatic detergent to achieve excellent cleaning results. The 90 degree optimum temperature achieved during the thermal cycle ensures efficient cleaning and disinfection and leaves instruments dry and ready for the sterilisation processes in compliance with the latest standards and guidelines. 4 factory programmed cycles Pre-Wash: In this stage the machine removes difficult gross contamination, including blood tissue debris, bone fragments and other fluid and solid debris. The water temperature of less than 45 degree C is used to prevent protein coagulation and fixing of soil to the instruments before the main wash cycle. Wash: Removes any remaining soil. The mechanical and chemical processes loosen and break up contamination adhering to the instrument surface. The enzymatic detergent automatically doses through the load. Rinse Cycle: The rinse stage removes detergent during the cleaning process and it is recommended the use of an RO water supply. RO systems available from Burtons, see page 2. Thermal Disinfection: The machine raises the temperature of the load and is held at the pre-set disinfection temperature for a specific time as defined within the EN15883 & HTM2030 standards. Forced air drying: (if selected) The final stage purges the load and chamber with heated air to remove residual moisture ensuring instruments are clean and dry and ready for sterilisation. 80 or 90 degree selectable
5 Washer Disinfector Supplied with: Stainless steel inner basket Stainless steel instrument basket Stainless tray rack ( holds up to 6 instrument cassettes/trays) Hand piece manifold for 6 hand pieces c/w quick release coupling for maintenance and easy cleaning Instawash enzymatic detergent 1ltr Instarinse rinse agent 0.5ltr All supply & drain hoses Optional extras Traceability printer Combined text, datalogger & printer Instaclip cassette Contra Angle tray Accessories & consumables: Instawash enzymatic detergent 1ltr Instarinse rinse agent 0.5ltr Washer disinfector test soil box of 10 bottles Dual temperature incubator 37/57 degree c Thermometer for incubator Process challenge device (inc 10 tests) Cleaning efficacy indicators pack of Nindydrin protein detection kit box of 25 tests Nindydrin protein detection test record sheets, pk of
6 Water Distillation Water Distillation Unit This automatic water distiller is very easy to use, produces over 4 litres of distilled water in only a few hours, and can be left running overnight, ensuring a full supply of distilled water for use with your autoclave each day. SAVE : This unit can produce over 16 litres of distilled water every 24 hours at an average cost of 8p per litre. No plumbing is required, no cartridges or filters, just fill with tap water and turn on the power. The water produced is ideal for use with your autoclave, dental system or other equipment requiring pure, distilled water. SAVE SPACE: Why store large quantities of water in bulky, heavy containers when a distiller will provide you with constant, pure, clean water every day and taking up a fraction of your valuable space! Stock code. Description Offer WATER DISTILLER MODEL MH PC COLLECTION BOTTLE ACTIVATED CHARCOAL FILTER FOR WATER DISTILLER. PACK CLEANER FOR WATER DISTILLER Technical information: Power: v/50Hz Power Consumption: 580W Weight: 3.5Kg Capacity: 4 Litres Dimensions: 20cm Dia. x 36cm High Autoclave Accessories AUTOCLAVE NYLON FILM AUTOCLAVE NYLON FILM 1IN AUTOCLAVE NYLON FILM 2IN AUTOCLAVE NYLON FILM 3IN AUTOCLAVE NYLON FILM 4IN AUTOCLAVE NYLON FILM 5IN AUTOCLAVE NYLON FILM 6IN AUTOCLAVE NYLON FILM 8IN AUTOCLAVE NYLON FILM 10IN AUTOCLAVE NYLON FILM 12IN AUTOCLAVE SELF SEAL POUCHES AUTOCLAVE SELF SEAL POUCHES 3.5IN X 9IN - (PACK 200) AUTOCLAVE SELF SEAL POUCHES 5.25IN X 10IN - (PACK 200) AUTOCLAVE SELF SEAL POUCHES 7.5IN X 13IN - (PACK 200) AUTOCLAVE SELF SEAL POUCHES 12IN X 15IN - (PACK 200) AUTOCLAVE TAPE AUTOCLAVE TAPE 18MM AUTOCLAVE TAPE 25MM 3.70 COLOUR I.D TAPE 7 COLOURS COLOUR I.D TAPE 7 COLOURS TST INDICATOR STRIPS 134C-3.5MIN C- 3.5MIN (BOX 100) C-15MIN (BOX 100) AUTOCLAVE NYLON FILM BAGS AUTOCLAVE NYLON FILM BAGS 4IN X 12IN AUTOCLAVE NYLON FILM BAGS 6IN X 12IN AUTOCLAVE NYLON FILM BAGS 12IN X 18IN TST BOWIE DICK TEST PACK C MIN (20PACKS) AUTOCLAVABLE NAIL BRUSHES AUTOCLAVABLE NAIL BRUSH ECONOMY AUTOCLAVABLE NAIL BRUSH SS HELIX TEST KIT HELIX TEST KIT WITH 250 INDICATOR STRIPS
7 Autoclaves Bench Top Autoclaves Stainless steel chassis Stainless steel chamber Easy drain facility Single use water system Simple cycle selection Digital temperature display Analogue pressure display Status progress indicators Optional independent process evaluation printer Process Evaluator Printer The printer monitors the performance of the autoclave and confirms that temperature and sterilising parameters are within regulatory limits. Confirmation of an effective sterilising cycle is indicated by a Pass Cycle Report. Deviation from regulatory limits is indicated by a Failed Cycle Report. The data output by the printer can be transferred directly to a PC and has been successfully integrated into fully traceable bar coded instrument system. The evaluator system can either be fitted at the factory from new or retrofitted at a later date. STOCK CODE DESCRIPTION OFFER MRRP SAVE 2530 S3 DWA 2530 NON VACUUM STANDARD 1, , S3 PDWA TL 2530 NON VACUUM WITH PRINTER & TEXT LOGGER 2, , , S S3 DWA 2545 VACUUM STANDARD 2, , , S S3 PDWA TL 2545 VACUUM WITH PRINTER & TEXT LOGGER 3, , ,458.00
8 Servicing Why pay massive service call out charges? TAKE THE WORRY OUT OF EQUIPMENT OWNERSHIP Get total peace of mind with a Burtons Fixed Service Contract WASHER DISINFECTOR ONCE A YEAR SERVICE TWICE A YEAR SERVICE Instawash 1000 PTL Instawash 3000 PTL Validation HTM01-05* AUTOCLAVES (Instaclaves 1230,2030,2530,230,3000) Little Sister MK Instaclave 2030 & 2530 Printer Instaclave 2545, 2545-V Instaclave 2545 & 2545-V Printer Instaclave 2060,2560,2560-V Little Sister MK2 & 3 SES Instaclave 2060,2560,2560-V Printer Instaclave 270,3000L Instaclave 2545 Vacuum Instaclave 2545 Vacuum Printer VALIDATION HTM01-05* Non Vacuum Model Vacuum Model s shown do not include parts (apart from comprehensive contract) and VAT. For further details and prices, please contact the service department on Breakdown calls 65 for twice yearly agreements and 75 for yearly agreements and are per item per visit. Breakdown calls to 2545 Vacuum machines and washer disinfectors *HTM 2010 and 2030 compliant validation is also available.
9 SERVICE AGREEMENT Between: Burtons Medical Equipment Limited And (Full name of principal - the user): Of (trading name and address of business) Postcode Tel No; Fax Mobile Please include full postal address, phone and fax number Equipment to be Serviced Description of equipment Serial Number No of visits per year DATE OF SERVICE TO COMMENCE. Charges will be as per the current service tariff price list, using the preferential rates for agreement customers. s are reviewed annually 1st July and are applied without notice. Please return to the Service Office, Burtons Medical Equipment Ltd. Please arrange for the above equipment to be serviced at the frequency specified. I acknowledge receipt of the current terms and conditions and agree to them. I understand I can cancel this agreement with one weeks notice in writing. Signature of behalf of the user Date Burtons Medical Equipment Ltd Guardian Industrial Estate, Pattenden Lane, Marden, Kent, TN12 9QD, England, U.K. (Registered in England. Company No )
10 Servicing Quality Equipment Backed By Quality Service The Burtons Difference! National coverage by full trained engineers - We come to you Autoclave, Washer Disinfectors and Dental Equipment Free service certificates - ready for your next inspection Validation carried out to HTM 01-05, HTM2010 & HTM2030 No call out charge - fixed price anywhere* No minimum period tie in Looking beyond the purchase When considering your next equipment purchase, how important to you is the level of after sales support you can expect to receive? At Burtons we believe that this is an extremely important factor to our business that sets us apart from our competitors. Nationwide support We currently employ a national network of 15 of our own fully trained and equipped service engineers able to carry out on site maintenance and repair in both the UK and Ireland. We also operate a modern, well equipped in-house facility to carry out repairs where this is not possible in the field. Why bother with a service contract? Planned preventative maintenance is your best defence against sudden failure of vital, frequently used equipment. Much of the equipment we see in practice today has been recycled and is of an age where failure of components is highly likely unless routine maintenance is carried out. Validation Not to be confused with a machine service, validation provides the evidence that the machine is performing as dictated in HTM Validation procedures should be carried out by a competent validation engineer. HTM guidelines require that the manufacture recommends the regularity of performance validation testing. Burtons can offer you complete solution to all your planned preventative maintenance and validation requirements laid out in HTM Our engineers are equipped with the latest data logging equipment combined with professional report writing software, these are produced both hard copy or PDF format. Peace of mind Equipment such as anaesthetic machines and autoclaves are fundamental to the prosperity of any veterinary practice. A service contract from Burtons provides comprehensive breakdown cover. Our aim is to attend site either the same day or within 24 hours reducing costly and disruptive downtime to a minimum. Our engineer will contact you within 3 hours to advise when they will attend site. Straight forward pricing Our service contracts have set labour charges, parts are charged for as and only when required, there are no upfront payments, you will receive an invoice once the work has been completed. We also offer a reduced rate for multiple items and group practices, plus, if you wish to cancel your contract, there is no tie in, you can cancel it with just a phone call. In house repair facilities We not only provide after sales support for all of the products in our range, we can also help you with repairs to other items too! So the next time something goes bang why not give us a call! In the majority of cases there is no charge for an estimate and if you decide not to proceed with the repair we will either return or dispose of the item for you. Please ensure that any item you intend sending has been thoroughly decontaminated first. We reserve t the right to return an item to you unrepaired if it is thought to be hazardous to the health of our employees. We now offer a straight forward inspection service that includes the supply of a safety inspection certificate to ensure that you are covered under these regulations. In most cases the inspection should be carried out annually and we can even add it to your existing service contract if you have one with us. For full details Tel: Fax:
11 Servicing Validation? HTM is the guidance document for those conducting decontamination within a Primary Care Dental Practice. One small section of this document is Validation this is the compliance to routinely have your Medical Devices such as Autoclaves and Washer Disinfectors validated. Decontamination Health Technical Memorandum 01-05: Decontamination in primary care dental practices Most common sterilizers found in Dental Practices are moist heat sterilizers which use steam to remove micro-organisms from the surgical instrument. This part of the decontamination process of a surgical instrument can only be as effective as the cleaning and disinfection stages to provide a sterile instrument, hence the requirement for validation. Each stage of validation must be carried out in accordance with a documented procedure, and shall verify that each item of equipment used during validation complies with its specification. The correlation between readings indicated and recorded by instruments fitted to the sterilizer and those readings logged by an independent test instrument which places sensors in similar locations all combine in the documented procedure of Validation. Because sterilizers perform a crucial role in prevention of cross infection, it s important that the correct type of sterilizer is being used to achieve this end result. Certain Types of sterilizers will require specific user verification test packs and also validation tests carried out by a competent engineer. These test procedures use calibrated logging equipment which will record data from the device and produce the evidence required in HTM for your CQC inspections. There are a number of different tests carried out during this process, dependent upon the type of machine you use. Examples such as; Automatic Control Test Air Leakage Test Thermometric Test Steam Penetration Test Cleaning Efficacy Test Burtons provide all the necessary service and validation requirements, ensuring all your relevant standards are maintained.
12 Rental Autoclave Rental No minimum hire period Routine service visits included Breakdown visits included All parts included Pressure vessel inspection & certification included Choice of models Upgrade at any time without penalty No capital outlay, no depreciation A UNIQUE FORM OF RENTAL Equipment rental is not a new concept. However, the Burtons Autoclave Rental Scheme differs from most others because it offers true rental. It is not a 3 or 5 year finance package in disguise and you are not tied to a contract for a fixed period. At a time when changes to autoclave specifications are proposed but not confirmed, short-term rental eases the pressure. Will you require vacuum? Are cycle validation printers to be mandatory? These decisions can be deferred until clear guidance or mandatory requirement is confirmed, safe in the knowledge that you are free to cancel the rental at any time and not be left with an expensive machine that you have purchased which no longer complies. Rental gives you the option to upgrade or change at anytime without penalty. Equally, since the rental is direct from the manufacturer with no finance costs our rentals are affordable in the longer term as well. no capital outlay, no depreciation. No servicing costs. No breakdown charges. Currently we offer the following rental options: INSTAWASH DISINFECTOR INSTAWASH WASHER DISINFECTOR 1000 MONTHLY RENTAL EXC VAT INCLUDING VALIDATION INSTAWASH WASHER DISINFECTOR 1000 WITH PRINTER & TEXT LOGGER INSTAWASH WASHER DISINFECTOR INSTAWASH WASHER DISINFECTOR 3000 WITH PRINTER & TEXT LOGGER INSTACLAVE SERIES 3 DISPLACEMENT (N) MODELS MONTHLY RENTAL EXC VAT INCLUDING VALIDATION WITH PRINTER/TEXT LOGGER INSTACLAVE SERIES 3 VACUUM MODELS MONTHLY RENTAL EXC VAT INCLUDING VALIDATION 2545 VAC VAC WITH PRINTER/TEXT LOGGER
13 How the scheme operates When you have chosen which model will be most suitable for your current needs we will arrange for either one of our customer support engineers to commission the machine when it arrives at your practice. Commissioning involves checking the machine for damage that may have occurred during transportation, setting the unit up and instructing your staff on how to operate it correctly. Once this has been completed you will be asked to sign the Direct Debit Mandater for the monthly payments. The date of the first payment will be 10 days after the day of commissioning. This allows a free trial period before the commencement of the rental period. If for any reason you are not happy with the machine during this time you can cancel the Direct Debit directly with your bank and inform us and we will collect the machine and you will have nothing to pay. If the reason for returning the machine is because you find it unsuitable for your needs and wish to proceed with an alternative from our range, the replacement will be supplied on a separate 10-day trial. After the 10 day trial the Direct Debit will be due on a calendar month basis each month in advance. The rental includes routine servicing (2 visits per year) and breakdown visits. At each service visit our engineer will complete a pressure vessel inspection to comply with the Pressure Systems 2000 Regulations and will give you a copy of the inspection report for your records. Our own engineers will carry out all servicing work. Your local engineer will contact you to arrange a convenient date for each visit. If you experience a problem with the unit between service visits please telephone our service department on: Burtons Service Direct Line Have a note of the model, serial number and the nature of the fault when calling. Your call will be logged and one of our engineers should contact you within 3 working hours to arrange a visit, if required. If you wish to return the machine simply contact us. We only ask for one months notice. There are no penalties for cancellation whether it is after 1 month or 10 years. Burton s reputation for delivering excellent products and services is second to none. If you do find it necessary to cancel we hope you will use us for your next machine whether it be a new rental or outright purchase.
14 RENTAL AGREEMENT (Customer s copy) Between: Burtons Medical Equipment Limited And (Full name of principal - the user): Of (trading name and address of business) Postcode Tel No; Fax Mobile Please include full postal address, phone and fax number The user agrees to rent an Instaclave model from Burtons. The initial monthly rental is The rental price will be reviewed from time to time and any increases will be advised with at least one months notice. Either party may cancel the rental with one month s notice in writing. Failure to make a full monthly payment will be taken as notice of cancellation although the payment for that month will still be owed. The user agrees to give reasonable access at all times to Burtons for servicing and inspection of the rental unit. Burtons reserves the right to swap the machine for an equivalent unit at any time. Ownership for legal and tax purposes will remain with Burtons. The user should insure the rental unit for fire, theft and accidental damage. The rental payments cover all routine service visits, breakdown visits and pressure vessel inspection and certification but not accidental or deliberate damage, misuse or other loss. Burtons will invoice separately for work (such as is deemed necessary at the sole discretion of Burtons) not covered by the rental. If after giving one months notice by either party Burtons are not permitted to collect the rental machine Burtons will invoice the user for the full list price and that invoice will become immediately due for payment. Burtons will make every reasonable endeavour to ensure the reliability of the machine but are not liable for any consequential losses. The user is responsible for deciding upon the suitability of the machine for the users applications. This agreement shall be subject to English Law. Signed by for the user. Date Print Name
15 RENTAL AGREEMENT (Burtons copy) Between: Burtons Medical Equipment Limited And (Full name of principal - the user): Of (trading name and address of business) Postcode Tel No; Fax Mobile The user agrees to rent an Instaclave model from Burtons. The initial monthly rental is The rental price will be reviewed from time to time and any increases will be advised with at least one months notice. Either party may cancel the rental with one month s notice in writing. Failure to make a full monthly payment will be taken as notice of cancellation although the payment for that month will still be owed. The user agrees to give reasonable access at all times to Burtons for servicing and inspection of the rental unit. Burtons reserves the right to swap the machine for an equivalent unit at any time. Ownership for legal and tax purposes will remain with Burtons. The user should insure the rental unit for fire, theft and accidental damage. The rental payments cover all routine service visits, breakdown visits and pressure vessel inspection and certification but not accidental or deliberate damage, misuse or other loss. Burtons will invoice separately for work (such as is deemed necessary at the sole discretion of Burtons) not covered by the rental. If after giving one months notice by either party Burtons are not permitted to collect the rental machine Burtons will invoice the user for the full list price and that invoice will become immediately due for payment. Burtons will make every reasonable endeavour to ensure the reliability of the machine but are not liable for any consequential losses. The user is responsible for deciding upon the suitability of the machine for the users applications. This agreement shall be subject to English Law. Signed by for the user. Date Print Name RENTAL AGREEMENT CHECKLIST ENSURE YOU HAVE COMPLETED THE FOLLOWING 1. BOTH COPIES OF THE RENTAL AGREEMENT 2. THE DIRECT DEBIT FORM OVERLEAF PLEASE NOW RETURN THE BURTONS COPY OF THE AGREEMENT AND THE DIRECT DEBIT MANDATE TO: Burtons, Guardian Industrial Estate, Pattenden Lane, Marden, Kent, TN12 9QD, England, U.K. ON RECEIPT OF YOUR APPLICATION, WE WILL CONTACT YOU TO ARRANGE DELIVERY AND INSTALLATION.
BESTPRACTICE. HTM01-05 Q&A: You can now follow us on Twitter! We have launched our HTM01-05 questions and answers service on Twitter.
ISSUE 4 BESTPRACTICE For Essential Requirements, hand washing is still a viable method of cleaning your instruments, but how do you validate for compliance with HTM01-05? Ensuring your instruments are
More informationSterilizers with extra class
Sterilizers with extra class ClassB Ready for the future The European standard EN 13060 specifies the performance requirements and test methods for small steam sterilizers. These are used for hygiene and
More informationClinic Washer-Disinfectors. Washer-Disinfector Line
Clinic Washer-Disinfectors Washer-Disinfector Line Easy-to-Use Washer-Disinfectors for Clinics The Clinic Range of Washer Disinfectors provides superior cleaning and disinfection combined with innovative
More informationInfection Control in the Dental Practice through Proper Sterilization
Midmark Corporation 60 Vista Drive P.O. Box 286 Versailles, Ohio 45380-0286 937-526-3662 midmark.com Infection Control in the Dental Practice through Proper Sterilization In today's world, the need for
More informationCliniklav 25. For highest quality in surgical applications MELAG. Evidence Based Sterilization
Cliniklav 25 For highest quality in surgical applications MELAG Evidence Based Sterilization Cliniklav 25 The big one from MELAG a powerful piece of technology Built-in printer for documenting program
More informationA new wave in instrument washing and disinfection Introducing the new HYDRIM G4 WD series
A new wave in instrument washing and disinfection Introducing the new HYDRIM G4 WD series Taking control of your infection control The hazards of manual cleaning Hand scrubbing is increasingly used less
More informationService with Care. Hygiene through innovation
Service with Care Hygiene through innovation Introduction Since 1991, DDC Dolphin have specialised in the Sluice and Dirty Utility Room environments, through continually developing and innovating our comprehensive
More informationFILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS
FILTRATION SOLUTIONS Pharmaceutical Manufacturing filtration specialists Delivering quality filtration products As one of Europe s leading manufacturers of process filters, Amazon Filters is able to offer
More informationTesting and validation for dentistry. quality. safety. schülke.
Testing and validation for dentistry quality. safety. schülke. Our great plus expertise in hygiene. schülke, industry leaders in infection control products and training are proud to announce a new partnership
More informationTabletop Line. Automatic and Semi-Automatic Autoclave Series
Tabletop Line Automatic and Semi-Automatic Autoclave Series Tuttnauer Your Sterilization & Infection Control Partner Company Profile For over 80 years, Tuttnauer s sterilization and infection control products
More informationUpdates on CFPP and Standards
Updates on CFPP and Standards CFPP 01-01 How Technical are the changes? R.Kingston Authorising Engineer (Decontamination) KSVAS Ltd. K Sterilizer Validation Advisory Services Ltd 1 Introduction R.Kingston,BSc.(Hons),C.ENG,MIMECHE,FIHEEM,
More informationModel Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/50 1100 1 Ø90x160mm W200xH385xD450 30 (Net:28)
Table Top STE-TEN STE-TEN, 1 Liter Autoclave It adopts B-wclass (pred-13060), with 3-times pre-vacuum preceding vacuum drying. Residual humidity is 0.2, vacuum measurement reaches -0.7bar. It sterilizes
More informationPORTABLE LABORATORY MODEL AVAILABLE!
S E L E C T I O N G U I D E LARGEST TABLETOP STERILIZER AVAILABLE! EASY TO PROGRAM TABLETOP STERILIZERS! QUICK PURE WATER FOR YOUR STEAM STERILIZER! FAST INDICATION AND EASY TO USE! HARVEY STERILIZERS
More informationACO Cleaning principles for drainage
Cleaning procedures ACO Cleaning principles for drainage Page Introduction 3 Principles of cleaning 4 Cleaning procedures ACO cleaning principles for drainage Cleaning chemicals 5 Manual cleaning of drainage
More informationSTATIM G4 Cassette Autoclaves From start to dry in the blink of an eye.
STATIM G4 Cassette Autoclaves From start to dry in the blink of an eye. STATIM, the world s fastest autoclave from start to sterile Drawing on over 20 years of innovation, Healthcare practitioners in over
More informationArrangements for the Maintenance and Testing of Laboratory Autoclaves
Arrangements for the Maintenance and Testing of Laboratory Autoclaves Royal Free NHS Trust & Royal Free and UC Medical School (Hampstead Campus) This document has been produced by the Safety Office, Royal
More informationFilterFlow Automatic Water Boilers. Pure Quality
FilterFlow Automatic Water Boilers Pure Quality Filtered hot water on tap Around the world we drink countless millions of cups of tea and coffee each and every day. The consumer s seemingly insatiable
More informationRULE 1102. DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE
(Adopted January 6, 1978)(Amended August 3, 1979)(Amended July 11, 1980) (Amended August 3, 1990)(Amended December 7, 1990) (Amended November 17, 2000) RULE 1102. DRY CLEANERS USING SOLVENT OTHER THAN
More informationBioSonic Ultrasonic Cleaning System. Ultrasonic Cleaning highly effective reaches into minute crevices instruments stay sharp and in shape
BioSonic Ultrasonic Cleaning System Ultrasonic Cleaning highly effective reaches into minute crevices instruments stay sharp and in shape BioSonic an essential part of your Infection Control System Ultrasonic
More informationSF15K SF05KSS, SF10KSS
Product Instruction Manual Speedflow SF05K, SF10K & SF15K SF05KSS, SF10KSS & SF15KSS Undersink unvented water heater V15.6/6 Version 3.2 Jan 2015 Thank you for purchasing a Hyco Speedflow unvented water
More informationLaboratory Line. Vertical and Bench-Top Life Science Autoclaves
Laboratory Line Vertical and Bench-Top Life Science Autoclaves The Advanced Laboratory Line The Full Spectrum of Laboratory Sterilizers Sterilization in a laboratory environment has its unique requirements.
More informationSterilization of Dental Instruments Dental Clinical Guidance
Scottish Dental Clinical Effectiveness Programme SDcep Sterilization of Dental Instruments Dental Clinical Guidance December 2011 Scottish Dental Clinical Effectiveness Programme SDcep The Scottish Dental
More informationFact Sheet on Steam Sterilizers at Stanford University
Fact Sheet on Steam Sterilizers at Stanford University By: Environmental Quality and Water Efficiency Group, Stanford University; December 2013 Jennifer Fitch, Marty Laporte, Julia Nussbaum, Adam Kern,
More informationPulseJetter Drain Cleaner
PulseJetter Drain Cleaner DRAIN LINE MAINTENANCE PJ-600 The PJ-600 Drain Cleaner is compact and rugged entry-level drain cleaner. It can be stored in a small utility closet and easily carried to the work
More informationguidance notes Form C
guidance notes Form C These guidance notes are designed to help you complete Form C Application for new water infrastructure and plot(s) connection for industrial/commercial development(s) Important: Form
More informationBench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
More information450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer
450 Analyzer 450 Analyzer Fast, Continuous Measurement Compliant with USP, Ch P, EP and JP USB Data Logging and Printer Output Robust Portable Design Portable, Real-time, Continuous Total Organic Carbon
More informationAUTOCLAVES. Table Top. STE-TEN, 1 Liter Autoclave
Table Top STE-TEN, 1 Liter utoclave STE-TEN It adopts B-wclass (pred-13060), with 3-times pre-vacuum preceding vacuum drying. Residual humidity is 0.2, vacuum measurement reaches -0.7bar. It sterilizes
More informationModel Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/50 1100 1 Ø90x160mm W200xH385xD450 30 (Net:28)
Table Top STE-TEN STE-TEN, 1 Liter Autoclave It adopts B-class (pred-13060), with 3-times pre-vacuum preceding vacuum drying. Residual humidity is 0.2, vacuum measurement reaches -0.7bar. It sterilizes
More information4 Stage Barracuda RO/DI Instruction & Owner s Manual
4 Stage Barracuda RO/DI Instruction & Owner s Manual 7208 Aloma Ave Suite 600 Winter Park, FL 32792 Phone 407-599-2123 Fax 407-599-2124 www.aquariumwaterfilters.com www.aquafx.net 7208 Aloma Ave Suite
More informationCompany background and. portfolio overview
Company background and portfolio overview A world leading company in infection control Steelco products are used daily in over 100 countries within the Healthcare, and Life Science sectors to provide the
More informationFundamental Autoclave Techniques
Fundamental Autoclave Techniques Version 3, September 2010 Veronika Tatarinoff GSBmE University of NSW Brandy Nelson University of Kentucky The following information is directed at aseptic/sterile surgical,
More information2. JOB PURPOSE To work as a team member in providing a high quality decontamination/sterilisation service for theatres, wards and departments.
GOLDEN JUBILEE NATIONAL HOSPITAL JOB DESCRIPTION 1. JOB IDENTIFICATION Job Title: Senior Technician Mentor Department(s): Central Sterile Processing Department (CSPD) Job Holder Reference: No of Job Holders:
More informationFAMILY PROTECTION FROM WATERBORNE DISEASES
A Product by : GIVE A 100% FAMILY PROTECTION FROM WATERBORNE DISEASES CATALOGUE 100% SAFE WATER LATEST JAPAN TECHNOLOGY ABOUT US We are introducing a unique Water Purifier with the proud name of Harshali
More informationLegionnaires disease: Technical guidance Part 3: The control of legionella bacteria in other risk systems
Legionnaires disease: Technical guidance Part 3: The control of legionella bacteria in other risk systems This guidance for dutyholders, including employers, those in control of premises and those with
More informationLiquid II Cell Culture Media Manufacturing Plant. Overview Facilities Water for Injection Sterile Environment Media Handling Cleanroom Interior
Liquid II Cell Culture Media Manufacturing Plant Overview Facilities Water for Injection Sterile Environment Media Handling Cleanroom Interior Overview History of BioConcept and Amimed BioConcept has close
More informationHospital Sterilizers. T-Max Line
Hospital Sterilizers T-Max Line Hospital Sterilizers Sterilization is a complex process. Like any complex process, many things can go wrong. A Hospital depends on its CSSD: Central Sterile Services Department.
More informationMedical Equipment Management Policy. Procedure No. 114
Medical Equipment Management Policy Page 1 of 18 Medical Equipment Management Policy Procedure No. 114 Print Name Title Date Prepared by Clinical Engineering 1 st June 08 Reviewed by Bernard Ryan Clinical
More informationFACT SHEET : Using Autoclaves Safely
CSULA Environmental Health and Safety Biosafety Office FACT SHEET : Using Autoclaves Safely Most science research laboratories on campus require the use of autoclaves. The primary purpose of the autoclave
More informationPartnership. Medical Waste Autoclaves. Medical Waste Autoclaves
Partnership Medical Waste Autoclaves Medical Waste Autoclaves Safe, Cost-Effective, Medical Waste Sterilization Keep your environment safe from Medical Waste with high performance Tuttnauer Medical Waste
More information2.3. The management in each HCF shall be responsible for ensuring good waste management practices in their premises.
1. PURPOSE Health-care activities lead to production of medical waste that may lead to adverse health effects. Most of this waste is not more dangerous than regular household waste. However, some types
More informationFOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
More informationMedical Waste Autoclaves. Medical Waste Autoclaves
Medical Waste Autoclaves Medical Waste Autoclaves Safe, Cost-Effective, Medical Waste Sterilization Treat Medical Waste with high performance Tuttnauer Medical Waste autoclave systems designed for small,
More informationWastewater Reuse. Typical treated wastewater is:
Wastewater Reuse Most metal finishing industries have in-house wastewater treatment to economically dispose of the acids, alkali, oils, and dissolved metals in the rinse water and occasional tank solution
More informationAUTOCLAVE STEAM STERILIZERS
AUTOCLAVE STEAM STERILIZERS (BENCH TOP) Image: HS-1606VD Hanshin Bench Top Steam Sterilizer Small and easy to operate Three preset sterilization cycles Adjustable cycle presets Rapid heat up times Option
More informationDetergents in CSSD. Wim Renders
Detergents in CSSD Wim Renders http://www.aqualitybv.eu Water is the solvent For pre-rinsing (cold): tap water In the ultra sonic cleaner: soft (preferably) or RO water; For manual cleaning: cold tap
More informationHow To Remove Iron From Water
ISR IRON REMOVAL MEDIA Description INDION ISR is a special media designed to provide excellent catalytic properties to remove dissolved iron from ground water. INDION ISR is an insoluble media which oxidizes
More informationW&H Sterilizers. Made-to-measure precision and perfection. Totally type B
W&H Sterilizers Made-to-measure precision and perfection Totally type B The brilliance of know-how A technical leap has been achieved: Lisa has become fully automatic. At the forefront of modern dentistry,
More informationSterilization methods and equipment Lab 1-2
Sterilization methods and equipment Lab 1-2 PHT 434 Sterilization Sterilization a process that by which all viable M.O are removed or destroyed, based on a probability function. Sterilization concept Sterilization
More informationVertical and Benchtop Autoclaves for Life Sciences. Laboratory Line
Vertical and Benchtop Autoclaves for Life Sciences Laboratory Line Designed for Your Laboratory Applications Advanced Laboratory Autoclaves Tuttnauer laboratory autoclaves have been designed to provide
More informationCare and use guide. Contents. a handy solution made easy. www.getbluelab.com. page
Care and use guide Contents page Features Quick guide Before use To operate Important - ph pen probe care 4 Cleaning 5 Battery replacement 5 Hydration 6 Calibration 6 Error messages 7 Troubleshooting guide
More informationOwner s manual. Free 5 year parts, 1 year labour gurantee Register your guarantee at www.dysonairblade.com
Owner s manual Free 5 year parts, 1 year labour gurantee Register your guarantee at www.dysonairblade.com Thank you for choosing to buy a Dyson Airblade MK2 hand dryer Dyson customer care Your hand dryer
More informationLABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de
LABOKLAV Autoclaves Made in Germany www.shp-steriltechnik.de 2 LABOKLAV STEAM STERILIZERS Steam sterilization is the sterilization method with the widest range of applications efficient, safe, reproducible
More informationWatts Pure Water Systems
Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
More informationCHEMICAL CLEANING UNIT Product number: 737189
CHEMICAL CLEANING UNIT Product number: 737189-1 - v.05/16 Content Page Intro 3 Specifications 4 Installation 5 Safety precautions 7 Maintenance 8 Spares and Accessories 8 Unitor Chemicals 9 Notes 10-2
More informationChemical Indicators & Accessories from Albert Browne International Ltd. Assurance through Technology
Chemical & Accessories from Albert Browne International Ltd Assurance Assurance What are Browne Chemical? Chemical The Browne range of chemical indicators has been categorised into six areas, broadly defined
More informationFMI Listeria Action Plan for Retail Delis
FMI Listeria Action Plan for Retail Delis November 2012 Listeria control at retail is an ongoing challenge. FMI and our members are committed to finding ways to control the growth and if possible, eliminate
More informationCar and commercial cial air conditioning service solutions
Car and commercial cial air conditioning service solutions THE STANDARD IN INFORMATION AND DIAGNOSTICS SYSTEMS INTRODUCTION For the KoolKare range of vehicle air conditioning service equipment we went
More informationKompressoren. Adsorption Dryer AD
Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated
More informationCal Water 1961 Petra Lane, Placentia, CA 92870 (800) CAL-WATER (800) 225-9283 FAX: (714) 792-0794 http://www.cal-water.com
Industrial Water Purification MAINTAINING A STERILE HIGH PURITY WATER SYSTEM Introduction Maintaining a microbe free deionized water system is like trying to maintain a vacuum, and nature abhors a vacuum.
More informationEquipment Breakdown. The extended property coverage you need for the equipment you rely on.
Equipment Breakdown The extended property coverage you need for the equipment you rely on. Equipment Breakdown When it comes to protecting the equipment and machinery you need to keep your business operating
More informationNu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition)
Product Description: Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition) The NU G System uses pyrolysis thermal decomposition to treat infectious wastes typically generated in hospitals.
More informationNewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
More informationNational Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
More informationHorizontal Steam Sterilizers. Healthcare Line. Since
Horizontal Steam Sterilizers Healthcare Line Since 1925 Horizontal Steam Sterilizers for Healthcare Applications The Tuttnauer line of healthcare sterilizers are designed for hospital operating rooms,
More informationDrinking water for Gaza Elaboration concept 2
Herontwerp 2014 Drinking water for Gaza Elaboration concept 2 Docent: Hassanpur Golriz, D. (Damon) Student: Roger Sylverstre Yapo (Group 4) Content 1) Reverse osmosis description --------------------------------------------------------------------------
More informationInstallation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
More informationGerman engineering under high pressure
German engineering under high pressure Over 25 years of experience as a manufacturer of sterilizers, autoclaves and lyophilization systems for laboratories, production and research Production-scale autoclaves
More informationSteam Sterilization Cycles for Lab Applications
Steam Sterilization Cycles for Lab Applications Presented by Gary Butler STERIS Life Sciences August 2009 Early Steam Sterilizers Koch Upright Sterilizer First Pressurized Sterilizer First built by Pasteur-Chamberlain
More informationSpeedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual
Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction
More informationLaboratory & Scientific Line. Bulk Steam Sterilizers. Since
Laboratory & Scientific Line Bulk Steam Sterilizers Since 1925 Bulk Steam Sterilizers for Laboratory & Scientific Applications The Tuttnauer line of bulk autoclaves are designed to handle the most critical
More informationUNITOR VACUUM cleaners
UNITOR VACUUM cleaners Unitor VCD15 a compact, heavy-duty dry vacuum cleaner for accommodation areas The smallest unit in the Unitor range, the VCD15 is purpose-made for use on cruise and passenger vessels.
More informationPapers. Papers. Abstract. Introduction
An evaluation of nine Bowie and Dick test products available in the United Kingdom Dr Brian Kirk, BSc, MSc, PhD, MRPharmS, FIHEEM, AE(D), Senior Technical Service Specialist, Sterilization and Monitoring,
More informationComplete. Water Solutions. for Rural India
Complete Water Solutions for Rural India More precious than gold. That s what safe drinking water is to India s rural population. Arsenic, iron, fluoride, nitrate, brackishness and pathogens in ground
More informationPAINT REMOVAL SYSTEM PAINT REMOVAL SPECIFICATION SAFE WORK METHOD STATEMENT FOR LEAD PAINT REMOVAL
PAINT REMOVAL SYSTEM PAINT REMOVAL SPECIFICATION SAFE WORK METHOD STATEMENT FOR LEAD PAINT REMOVAL CONTENTS: 1.0 AWARENESS AND PRECAUTION 2.0 TEST SAMPLING & REMOVAL EVALUATION 3.0 SITE EVALUATION 4.0
More informationGuidance on safe use of Autoclaves
Safety Office Reviewed: Dec 2013 Reviewed: DD Month Year Guidance on safe use of Autoclaves 1. Hazards & Uses There are several different types of hazard associated with the use of autoclaves. The main
More informationAustralian/New Zealand Standard
AS/NZS 4187:2003 AS/NZS 4187 Australian/New Zealand Standard Cleaning, disinfecting and sterilizing reusable medical and surgical instruments and equipment, and maintenance of associated environments in
More informationGETINGE CLEAN MANAGEMENT SYSTEM
GETINGE CLEAN MANAGEMENT SYSTEM 2 Getinge Clean Management System GETINGE CLEAN MANAGEMENT SYSTEM (CMS) AN IMPROVED PROCESS, A UNIQUE SOLUTION Getinge can help you manage your detergents and reduce costs.
More informationSimply complete the enclosed Warranty Form with contact details, or email us with your details and date of purchase.
INSTALLATION & SERVICE GUIDE 4 STAGE UNDERSINK REVERSE OSMOSIS WITH SERVICE MODE Congratulations on your purchase of the most advanced Reverse Osmosis Water Purification system available. Part of our commitment
More informationPeninsula Community Health. Safe Use of Mattresses, Pressure Relieving Cushions and Pillows
Peninsula Community Health Safe Use of Mattresses, Pressure Relieving Cushions and Pillows Title: Procedural Document Type: Reference: Safe Use of Mattresses, Pressure Relieving Cushions and Pillows Policy
More informationDISINFECTION & STERILIZATION INFECTION CONTROL GUIDELINES SECTION 4 QUALITY MANAGEMENT IN STERILIZIATION
DISINFECTION & STERILIZATION INFECTION CONTROL GUIDELINES SECTION 4 QUALITY MANAGEMENT IN STERILIZIATION Section 4 - Quality Management in Sterilization Quality management in sterilizing services Quality
More informationwww.morphyrichards.co.uk
43922 rev2:x 06/01/2010 15:06 Page 1 Upon registration with Morphy Richards (UK & ROI only) Register online for your 2 year guarantee. See back of this instruction book for details. (UK and Ireland customers
More informationBest Management Practices for Mercury Waste Management in Dental Offices
Best Management Practices for Mercury Waste Management in Dental Offices Mercury Waste Best Management Practices (BMPs) for Dental Facilities are designed to comply with environmental regulations, prevent
More informationORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
More informationThe Premium-Plus-Class Now even better
The Premium-Plus-Class Now even better Innovation and quality the philosophy of a family-run business As an owner-run and operated family concern founded in 1951, we have a long history of successful specialization
More informationSterilization of narrow channels: how to ensure effectiveness in daily routine? Dr.ir. Josephus Paulus Clemens Maria Van Doornmalen Gomez Hoyos
April 2015 Sterilization of narrow channels: how to ensure effectiveness in daily routine? Dr.ir. Josephus Paulus Clemens Maria Van Doornmalen Gomez Hoyos 3M Deutschand GmbH, IPD, Decontamination University
More informationRevised 4-3-2012 EHS Biosafety. 1 Select appropriate containers/bags for autoclaving.
Requirements for Decontamination by Autoclaving Summary: Steam sterilization (autoclaving) is one of the most effective methods for decontaminating biohazardous material. Autoclaves use saturated steam
More informationWARRANTY BOOKLET. Commercial Water Heaters. Register online at www.rinnai.com.au
WARRANTY BOOKLET Commercial Water Heaters Register online at www.rinnai.com.au Rinnai Commercial Water Heating Products Warranty Warranty Terms The benefits to the consumer given by this warranty are
More informationAssembly and Installation Procedures
Assembly and Installation Procedures for Pall Pharmaceutical Grade Capsule Assemblies 1. Introduction The following procedures must be followed for the installation of Pall pharmaceutical grade capsule
More informationOT 40L / 90L. Laboratory Steam Sterilizers
OT 40L / 90L Laboratory Steam Sterilizers OT 40L / 90L LABORATORY STEAM STERILIZERS OT 40L / OT 90L laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture
More informationSTANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA
STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA SOP#: 1005.7 Date Issued: 10/98 Date Revised: 2/16 Page 1 of 7 TITLE: SCOPE: RESPONSIBILITY: PURPOSE: Animal Care
More informationNÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. Esenboğa Yolu 22 km Akyurt - ANKARA / TURKEY Tel : (00 90 312)
More informationStenner Pump Chlorinator Installation & Start Up Guide
Clean Water Made Easy www.cleanwaterstore.com Stenner Pump Chlorinator Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationSTEAM STERILIZERS. DLOV & DLOM series. more than fifty years of experience in sterilization. DE LAMA s Quality Management System is certified:
STEAM STERILIZERS DLOV & DLOM series DE LAMA s Quality Management System is certified: more than fifty years of experience in sterilization UNI EN ISO 9001:2000 - Cert. n 0351 UNI EN ISO 13485 - Cert.
More informationSTABITHERM INSTALLATION & SERVICE BOOKLET
STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow
More informationCAREPLUS CARE AND MAINTENANCE GUIDELINE Page 1 of 5
CAREPLUS CARE AND MAINTENANCE GUIDELINE Page 1 of 5 PROACTIVE CLEANING TO MAINTAIN CAREPLUS CARPET Without regular removal, dirt and soil accumulates to grind and permanently damage fibres, so carpets
More informationKOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS
KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS THE STANDARD IN INFORMATION, EQUIPMENT AND DIAGNOSTICS SYSTEMS h t t p : / / d i a g n o s t i c s. s n a p o n. c o. u k KOOLKARE INTRODUCTION
More informationUNITOR ULTRASONIC cleaning
UNITOR ULTRASONIC cleaning ULTRASONIC machines Unitor Ultrasonic cleaning machines are specially designed for use in the ship s engine room to remove even the most stubborn dirt. Compared with traditional
More information