Exposure to Airborne Endotoxins among Sewer Workers: An Exploratory Study

Size: px
Start display at page:

Download "Exposure to Airborne Endotoxins among Sewer Workers: An Exploratory Study"

Transcription

1 Ann. Occup. Hyg., 2014, 1 11 doi: /annhyg/met085 Exposure to Airborne Endotoxins among Sewer Workers: An Exploratory Study Philippe Duquenne 1 *, Denis Ambroise 2, Pierre Görner 1, Frédéric Clerc 1 and Guylaine Greff-Mirguet 1 1.Département Métrologie des Polluants, INRS, 1 rue du Morvan CS 60027, Vandœuvre-lès-Nancy Cedex, France 2.Pôle Médico-Social des Côtes de Meuse, 74 rue R. Poincaré, Vigneulles-les-Hattonchâtel, France *Author to whom correspondence should be addressed. Tel: ; fax: ; philippe.duquenne@inrs.fr Submitted 20 June 2013; revised 16 December 2013; revised version accepted 16 December Abstract Exploratory bioaerosol sampling was performed in order to assess exposure to airborne endotoxins during sewer work. Personal samples were collected in underground sewer pipes using 37-mm closed-face cassettes containing fibreglass filters (CFC-FG method) or polycarbonate filters (CFC-PC method). Endotoxins were quantified using the limulus amoebocyte lysate assay. Concentrations of airborne endotoxins at sewer workplaces ( EU m 3 ) were higher than those measured outside the sewer network ( EU m 3 ). Sewer worker exposure to airborne endotoxins depended on the workplace and on the tasks. Exposure levels were the highest for tasks involving agitation of water and matter, especially for chamber cleanup and pipes cleanup with a high-pressure water jet. Airborne endotoxin levels at the workplace tended to be higher when CFC-FG was used as the sampling method rather than CFC-PC. The adjusted mean of the measured concentrations for CFC-PC represents 57% of the mean observed with CFC-FG. The number of samples collected in the descriptive study was too low for drawing definitive conclusions and further exposure investigations are needed. Therefore, our exploratory study provides new exposure data for the insufficiently documented sewer working environment and it would be useful for designing larger exposures studies. Keywords: bioaerosols; endotoxin; occupational exposure; sewer; wastewater Introduction Sewage systems are essential for draining and carrying raw wastewater from municipalities. Sewer systems are complex networks made up of underground pipe galleries that run below city streets (Pfafflin and Ziegler, 2012). They collect rainwater, domestic wastewater, and industrial effluent for treatment and disposal at wastewater treatment facilities. Manholes afford ready access to larger sewer pipes when they intersect or change direction (Pfafflin and Ziegler, 2012). Raw wastewater carries a large amount of suspended matter (sand, sludge, grease, and waste) that may deposit in pipes and disturb the water flow or obstruct the pipes. Sewers also deteriorate over time and thus, the sewer network needs to be periodically cleaned out and repaired. These operations are generally performed by trained employees. Sewer pipes are enclosed spaces where employees can be exposed to chemical pollutants such as hydrogen sulphide (Richardson, 1995). Raw The Author Published by Oxford University Press on behalf of the British Occupational Hygiene Society. 1

2 Page 2 of 11 Exposure to Airborne Endotoxins among Sewer Workers wastewater also contains a large quantity and a wide variety of microorganisms including bacteria, fungi, viruses, protozoa, helminths as well as their metabolites and products (Gerardi and Zimmerman, 2005). Depending on the biological agents and on the route of exposure, these microorganisms can induce biological risks among exposed workers. Indeed, epidemiological investigations suggest a higher prevalence of gastrointestinal tract symptoms, respiratory symptoms, fatigue, and headache among employees at sewage treatment plants (Lundholm and Rylander, 1983; Rylander, 1999; Thorn and Kerekes, 2001; Thorn and Beijer, 2004). Infectious diseases caused by bacteria and viruses (hepatitis A) are also reported but their occurrence seems to be restricted to cluster groups of workers and related to general hygiene behaviours (Thorn and Kerekes, 2001; Jeggli et al., 2004). Airborne endotoxins and Gram-negative bacteria were suggested as possible causative agents of airway and intestinal symptoms among workers in wastewater treatment plants (Rylander, 1999; Thorn and Beijer, 2004). Endotoxins are a major cell wall component of Gram-negative bacteria that are ubiquitous in the environment and may become airborne particles during normal working operations in sewers. Exposure to airborne endotoxins has been associated with workrelated respiratory and general symptoms in different occupational environments (Rylander, 2002; Douwes et al., 2003; Liebers et al., 2006). Thus, the assessment of exposure to endotoxins has received much attention and the concentration of airborne endotoxins has been documented for a wide range of workplaces (Duquenne et al., 2013). For work with sewage, most of the published studies were carried out in wastewater treatment facilities (Laitinen et al., 1994; Laitinen et al., 2001; Thorn et al., 2002; Oppliger et al., 2005; Smit et al., 2005; Visser et al., 2006; Spaan et al., 2008) and data regarding work in sewer pipes are scarce (Neumann et al., 2002). As a consequence, the exposure of sewer workers to endotoxins is as yet insufficiently documented and further research is needed to fill this gap in knowledge. Sampling on filters is the most widely used method in the literature for airborne endotoxins (Duquenne et al., 2013). But the diversity of sampling system (i.e. filter holder + filter) configurations as well as of analytical protocols used in studies may induce variability in exposure estimates from one laboratory to another (Reynolds et al., 2002; Chun et al., 2006; Spaan et al., 2007; Thorne et al., 2010). In particular, numerous published studies use polycarbonate membranes as sampling filters (Duquenne et al., 2013), in spite of Standard EN recommending that fibreglass filters (CEN, 2003) be used. The type of bioaerosol being sampled and the type of sampling filter used have been suggested as important factors in the overall efficiency of the endotoxin measurement process (Gordon et al., 1992; Reynolds et al., 2002). Polycarbonate membranes have been shown to underestimate the endotoxin levels measured in various occupational environments but no data are available for work in sewers. Exploratory measurements of bioaerosols were performed in the underground sewer pipes of a city in France. The aim of the study was to assess the exposure of sewer worker to airborne endotoxins. Additionally, the study presents data from field application of the sampling on filter method with fibreglass filters as well as polycarbonate membranes. Materials and Methods General description of the sewerage system The study was carried out in the sewerage system of a city with a population of several hundred thousand in Southern France. It is the main town (not cited for confidential reasons) of an urban agglomeration that is one of the 10 most populated in the country. The sewer network of the city collects domestic wastewater, rainwater, and wastewater and effluent from workshops, small industries, and commercial buildings. It is made up of underground pipe galleries that channel and convey wastewater to the wastewater treatment facility located a few kilometres away from the city. Manholes allow workers to go down into the largest pipe galleries for inspection and maintenance. Description of the work tasks The sewer workers activities that we focused on were those involved in inspecting and cleaning the sewer. The city employs 179 sewer workers. One group of workers (129 persons) is entirely dedicated to pipes inspection and another one (50 persons) is entirely dedicated to cleaning activities (pipes cleanup, chamber cleanup, tanker lorry unloading). Work is usually done by teams of three to six workers and for a 6-h

3 Exposure to airborne endotoxins among sewer workers Page 3 of 11 work shift. For workers involved in cleaning activities, the pipes cleanup, chamber cleanup, tanker lorry unloading tasks account, respectively, for 38, 50, and 12% of the work shift (estimates from the city). Thus, the occupational exposure of the sewer workers to endotoxins was evaluated for the work tasks during which they were believed to be exposed to bioaerosols. Pipes inspection The aim of the pipes inspection task is to define the places where the sewer network needs to be cleaned or repaired (Fig. 1). To achieve this, the sewer workers walk along the man-accessible pipe galleries for making a visual inspection and recording anomalies. Pipes cleanup The aim of the pipes cleanup task is to clean the pipe galleries in order to clear them of accumulated matter (sand, sludge, grease) that can disturb the wastewater flow. Workers achieve this operation by removing the accumulated matter from the sewer walls and by gathering the resulting sludge under the nearest manhole. The sludge is then removed from the pipes and sent for storage to a tanker lorry by sewer workers using a pumping device. In our study, three different removal and gathering methods were used by the sewer workers. A high-pressure water jet and scraper tools were used for man-accessible galleries. Narrow galleries that could not be visited were washed with a stand-alone water pressure flushing system that flushed out silt and sedimented matter from a manhole to another collection point. The operation was conducted from street level by workers who were not inside the galleries while the water pressure flushing system was in operation. Chamber cleanup Sedimentation chambers specially designed for deposition of suspended matter from water have been built throughout the network. The aim of the chamber cleanup task is to clean these chambers in order to clear them of accumulated matter (sand, sludge, grease). The water flow is bypassed so that sewer workers are able to walk down to the sedimentation chamber to clean it. The sludge is then removed from the chamber and sent for storage into a tanker lorry by workers using a pumping device. Tanker lorry unloading The tanker lorry unloading task is an operation aimed at removing the sludge from the tanker lorry and at 1 A sewer worker using a manhole for accessing underground pipe galleries for pipes inspection.

4 Page 4 of 11 Exposure to Airborne Endotoxins among Sewer Workers cleaning out the lorry. In our study, this very short operation (a few minutes) was done outside at the wastewater treatment facility. Firstly, the tanker lorry was unloaded automatically. Then, the sewer workers entered the tank to clean it and to remove residual sludge from the inner walls using a high-pressure water jet. Methods for bioaerosol sampling Airborne inhalable endotoxins were sampled by the filtration method using 37-mm polystyrene three-piece closed-face cassettes (CFCs) provided by Millipore (Molsheim, France). Each CFC was mounted with a sterile collection filter and a backing cellulose pad thick cellulose absorbent pad, Millipore, Molsheim, France. Two different filters were used in our study; the CFC-PC contained a sterile polycarbonate filter (Nuclepore, 0.8-mm pore size, Millipore, Molsheim, France) and the CFC-FG contained a fibreglass filter (Whatman, FG/B glass microfibre filter, grade GF/B: 1 μm, thickness: 0.68 mm, Sigma-Aldrich, Lyon, France). Initial endotoxin contamination of filters was below 0.05 EU per filter. To achieve sampling, each CFC was connected to a portable pump (GilAir, Gilian AD Air Solutions, Metz, France) operating at the nominal flow rate of 2 l min 1. The flow rate was calibrated before and after sampling using a bubble flow meter (Gilibrator, Gilan, AD Air Solutions, Metz, France). The duration of sampling depended on the duration of the investigated work tasks and ranged from 9 to 98 min (median: 60 min). The duration of sampling for the tanker lorry unloading task was the shortest (9 min). Sampling strategy and experimental design The measurements of airborne endotoxins were taken at 13 different worksites that were located all across the city and selected on the basis of the scheduled working program. Bioaerosol samples were collected from March to June following a non-balanced experiment plan (Table 1). Unexpected changes in the program of work on the sewers and in the availability of operators Table 1. Experimental design used to assess the exposure of sewer workers to endotoxins Working tasks Working sites Number of collected samples CFC-FG exposure measurements CFC-PC exposure measurements Background measurements Pipes inspection A B C D Chamber cleanup E Pipes cleanup Water pressure flushing system F G H High-pressure jet I High-pressure jet J Scrapper tools K Scrapper tools L Tanker lorry unloading M Duration of sampling (min)

5 Exposure to airborne endotoxins among sewer workers Page 5 of 11 wearing samplers prevented us from following the balanced sampling plan we initially designed. The number of worksites per task was 4, 5, 3, and 1 for the pipes inspection, the pipes cleanup, the chamber cleanup, and the tanker lorry unloading tasks, respectively. Simulated individual samples were collected in triplicate with CFC-FG and CFC-PC at the 13 different worksites and inside the sewer network. Sampling was performed by placing three identical sampling devices (i.e. three CFC-FG or three CFC-PC devices) in the breathing zone of an operator. The sampling devices were not worn by sewer workers since their work activity was hindered by the sampling equipment. Therefore, it was decided to place the sampling devices on an independent person (laboratory technician) who was located as close as possible to the sewer workers to mimic personal exposure (Fig. 2). When a specific working task was investigated, the CFC-FG and CFC-PC sampling devices operated simultaneously and were worn by two different operators who stood very close to each other. The background level of airborne endotoxins was determined for each worksite by sampling bioaerosols outside the sewer network. This was done in parallel with the endotoxin exposure measurements performed inside the sewer network and achieved by placing one CFC-PC filter sampling device on the breathing zone of a laboratory technician. The technician was located at street level, usually some distance from the manhole used by sewer workers to access the sewer areas to clean or to inspect and was not involved in the work tasks (Fig. 2). Field negative controls were made with FG filters and PC filters that were not used for sampling. Bioaerosol samples were sent to the lab using iceboxes within 12 h after sampling and were stored at 4 C pending analysis. Sample analysis The samples were analysed within 24 h after sampling. All the operations were performed in a Microbiological Safety Cabinet and with sterile and pyrogen-free disposable material. Filter samples from the CFCs were pre-treated to extract the endotoxins from the filter material before analysis. Each filter was carefully removed from the sampling cassette and aseptically transferred to a 50-ml sterile and pyrogen-free propylene tube (Cellstar tubes, Greiner Bio-One, Courtaboeuf, France) containing 5 ml of pyrogen-free water (Aqua B. Braun, B. Braun, Chasseneuil, France). Each tube was shaken for 1 min using a vortex agitator operating at 2500 r.p.m. (Reax 2 Schematic representation of pipe galleries and of the positions of samplers for individual measurement of workers exposure to endotoxins. Samplers were operating simultaneously when they were compared; they were carried by two different operators who stood up very close to each other and as close as possible to the sewer workers.

6 Page 6 of 11 Exposure to Airborne Endotoxins among Sewer Workers Control, Heildolph-Serlabo-technologies, Entraigues sur la Sorgue, France) and was plunged for 20 min in an ultrasonic bath (Bronson 1210, Bronsonic, Bronson Ultrasonic Corporation, Geneve, Switzerland) operating at 47 KHz and 60 C. After sonication, each tube was shaken for 1 min at 2500 r.p.m. on the vortex agitator. The extracts were filtered through a 0.22-μm pyrogen-free polyethersulfone membrane (Millex -GP, Millipore, Molsheim, France). The amount of endotoxins in the solutions was determined by the kinetic chromogenic limulus amoebocyte lysate (LAL) method as fully described previously (Duquenne et al., 2012). The LAL reagent kit (Kinetic-QCL, Lonza, Lyon, France) was used for the assay according to the recommendations of the supplier. The reagent kit included the lyophilized endotoxin from Escherichia coli 055:B5 (E. coli 055:B5 endotoxin, batch 2L6560) as control standard endotoxin (CSE), the lyophilized LAL reagent (Kinetic- QCL reagent, batch 2L151M), and the LAL reagent water (batch 3L1720). The LAL reagent water and the CSE were used as negative and positive controls, respectively. Samples were spiked with a known concentration of endotoxins to assess the interferences. Analysis results were expressed as endotoxin units per millilitre (EU ml 1 ) and the assay limit of detection was EU ml 1, and values from field negative controls were subtracted from concentration of endotoxins in the extract. Expression of results and statistical analysis The concentration of endotoxins in the air was expressed as EU m 3. As the number of samples collected was too low for a robust statistical analysis, data were presented and discussed on the basis of raw values, means (arithmetic and/or geometric ones), standard deviation, and confidence interval at 95% (CI95). Results Endotoxin levels in field blanks were from <0.025 to 0.03 EU per filter for CFC-PC and <0.025 to 0.3 EU per filter for CFC-FG. Background level of endotoxins Airborne endotoxins were measured outside the sewer network for 11 out of 13 sampling sites. Samples from two worksites were lost during analysis. The recorded endotoxin concentrations were lower than 5 EU m 3 for six samples among all the collected ones, and the endotoxin values ranged from 5 to 10 EU m 3 for three samples (Table 2). Two other samples exhibited higher values: 122 EU m 3 and 51 EU m 3. Simulated personal exposure Sampling with CFC-FG and CFC-PC devices enabled 78 bioaerosol samples to be collected during the work inside the sewer. Exposure values ranged from 13 to 440 EU m 3 when samples were collected using the CFC-FG method with a geometric mean of 85.3 EU m 3 (Table 2). They ranged from 6.0 to 420 EU m 3 when they were collected using the CFC-PC method with a geometric mean of 48.9 EU m 3. The levels of exposure to endotoxins inside the sewerage system were higher than those observed outside (i.e. the background levels). Endotoxin concentrations measured using CFC-FG during the chamber cleanup work task ranged from 79 to 260 EU m 3 with a geometric mean concentration of 163 EU m 3 (Table 2). They ranged from 37 to 239 EU m 3 when measured using the same method during the pipes inspection task with a geometric mean concentration of 85 EU m 3. Data from CFC-FG samples also indicate that exposure levels measured during the pipes cleanup task varied over a wide range as a function of the method used to clean the pipes. Particularly, the use of a high-pressure water jet to clean the pipes led to higher values for endotoxin exposure (from 141 to 440 EU m 3 ) than the use of scraper tools (from 15 to 92 EU m 3 ) and of the water pressure flushing system (from 13 to 16 EU m 3 ). CFC-FG samples collected during the tanker lorry unloading tasks led to concentrations from 33 to 53.4 EU m 3. Similar tendencies were observed when exposure was assessed using CFC-PC (Table 2). However, the endotoxin concentrations measured with the CFC-FG method were higher than those observed with the CFC-PC method for 27 samples among the 39 collected ones (data not shown). The geometric mean of CFC-PC measurements was 57% of the mean observed with CFC-FG measurements. The geometric mean concentration of airborne endotoxins measured with CFC-PC was 123.9, 45.2, 33.9, and 19 EU m 3 for the chamber cleanup, the pipes cleanup, the pipes inspection, and the tanker lorry unloading

7 Exposure to airborne endotoxins among sewer workers Page 7 of 11 Table 2. Exposure of sewer workers to endotoxins as a function of working task and working site Working tasks Working sites Endotoxin exposure (EU m 3 ) Background measurements CFC-PC measurements a CFC-FG measurements a AM Min Max SD CI95 AM Min Max SD IC95 Pipes inspection A % % 0.7 B % % 2.6 C % % 4.5 D % % 8.6 Chamber cleanup E % % nd Pipes cleanup Water pressure flushing system F % % 51.4 G % % 2.1 H % % 5.4 High-pressure jet I % % J % % 2.9 Scrapper tools K % % 7.9 L % % 0.4 Tanker lorry unloading M % % nd Bioaerosol samples were collected using 37-mm closed-face cassettes containing fibreglass filters (CFC-FG) or polycarbonate filters (CFC-PC). AM, arithmetic mean; CI95, confidence interval at the confidence level of 95%; nd, not detected; SD, standard deviation. The background level of endotoxins was measured using one CFC-PC. a Calculated from three replicates (i.e. three identical sampling devices placed in the breathing zone of an operator).

8 Page 8 of 11 Exposure to Airborne Endotoxins among Sewer Workers activities, respectively. The highest CFC-PC exposure levels were measured during the chamber cleanup task (from 31 to 421 EU m 3 ) and when a high-pressure water jet was used to clean the pipes during the pipes cleanup task (from 87 to 186 EU m 3 ). Endotoxin concentrations from triplicate samples varied over a wide range (CI from 3 to 53% for CFC-FG) but with no obvious trend emerging when considering worksites, work tasks, or sampling method (Table 2). Discussion Background levels of airborne endotoxins Air samples were collected outside the sewer network to determine the background endotoxin exposure levels of workers when standing in an area not affected by the operational activities. Endotoxin values lower than 5 EU m 3 corroborate those reported in a previous study for the level of endotoxins in the outdoor air of urban areas (Mueller-Anneling et al., 2004; Madsen, 2006). We assumed that values from 5 to 10 EU m 3 were of the same order of magnitude, but values higher than 50 EU m 3 were not expected. For the two values higher than 50 EU m 3, we noted that the sampling devices were worn by operators who were located close to the sewer manhole. In that situation, the sampling devices were located above a sewer area where the pipes cleanup (background level: 122 EU m 3 ) and chamber cleanup (background level: 51 EU m 3 ) activities were in progress. It is supposed that these operators were exposed to bioaerosols generated by the workers inside the sewerage system via the manhole as no other sources were identified around. This suggests that manholes may constitute a source of exposure for people in the surrounding area. Significance of worker exposure to airborne endotoxins Results from CFC-FG and CFC-PC samples suggest that sewer employees were exposed to airborne endotoxins during their work. In our study, higher amounts of airborne endotoxins were observed inside the sewer network compared with background level. Very little data have been published at international level about exposure of workers to bioaerosols in underground sewer networks before any treatment of the wastewater. Prior studies have demonstrated that work activities in a sewer network increase the total number of airborne cultivable microorganisms (Karpinski et al., 2000; Neumann et al., 2002; Haas et al., 2010). Furthermore, endotoxin exposures up to 800 EU m 3 were reported in one German survey carried out in the same occupational environment (Neumann et al., 2002). Thus, our data corroborate those findings and provide a new contribution to the knowledge of occupational exposure to endotoxins in sewers. Sampling devices were not worn by workers in our study. Although operators wearing the samplers stood as close as possible to the target working activities, our measurements might slightly underestimate the real exposure levels for some situations. This is probably the case for the chamber cleanup and pipes cleanup with the high-pressure water jet tasks for which narrow pipe sections did not always allow a rigorous survey of tasks to be conducted throughout their durations. But such situations happened rarely. For the other tasks, monitoring was easier and we think that our measurements are representative of real exposure. Our study and the few previous ones suggest that endotoxin exposure levels do not exceed 1000 EU m 3 during work with raw wastewater, which is lower than those reported in other occupational environments. By way of comparison, ambient endotoxin concentrations have been measured from 0.1 to 3500 EU m 3 (Laitinen et al., 1994; Thorn et al., 2002; Visser et al., 2006) and exposure levels from 0.6 to 4160 EU m 3 (Thorn et al., 2002; Smit et al., 2005; Visser et al., 2006, Spaan et al., 2008) in wastewater treatment plants. Endotoxin concentrations higher than 5000 or even EU m 3 have been recorded in the air of composting facilities, and during grain handling or transformation (Spaan et al., 2006; Halstensen et al., 2007; Duquenne et al., 2012). Effects of work task on exposure to endotoxins The number of samples collected in the present study is too low for a robust statistical analysis and no definitive conclusions can be drawn from our results with regard to the effect work tasks on endotoxin levels. In our study, employees were mainly exposed to endotoxins during work practices for which agitation of wastewater and deposits occurred, such as the chamber cleanup task and the pipes cleanup task with a high-pressure water jet. Indeed, agitation of water generated bioaerosols in the workers breathing zones

9 Exposure to airborne endotoxins among sewer workers Page 9 of 11 and the phenomenon might be amplified by the confinement of work tasks. Such a relationship between wastewater or sludge agitation and occupational exposure to bioaerosols has already been observed in wastewater treatment facilities (Laitinen et al., 1994; Thorn et al., 2002; Sanchez-Monedero et al., 2008). The variability in concentrations during the pipes cleanup task using scraper tools and the pipes inspection task might be due to changes in the amounts of deposits that were shifted by workers, to the variable levels of contamination of these deposits, or to the proximity of agitated wastewater. Interestingly, CFC-FG measurements (up to 240 EU m 3 for worksite B) indicate that workers may be exposed to endotoxins during the pipes inspection task (Table 2); they probably visited areas with agitated water during their inspection. The lower endotoxin levels (<50 EU m 3 ) observed during the pipes cleanup task using the water pressure flushing system were not surprising since the sewer workers were some distance away from the aerosols created by the water pressure jet (see task description). The tanker lorry unloading is a very short task; it was investigated once throughout the study and further measurements are required. These results suggest that exposure levels to endotoxins were dependent on the work tasks, but a larger study is needed to confirm this statement. A possible influence of filter material on endotoxin measurements In our study, the use of FG filters tended to lead to higher endotoxin exposure levels than PC filters. Direct comparison of the CFC-FG and the CFC-PC sampling methods cannot be made rigorously as the number of samples is low and as samplers were worn by different workers. Previous field studies showed that fibreglass filters yielded higher airborne endotoxin estimates than PC filters (Thorne et al., 1997; Laitinen, 1999; Görner et al., 2006). Differences between filters were ascribed to the ability of the filter material to set endotoxins free during the extraction step and particularly to the capacity of endotoxins to be adsorbed in the filter material. Fibreglass filters may be unfavourable to this phenomenon. Other published studies also suggested that the results of airborne endotoxin measurements depended both on the characteristics of the collection filter and on the nature of the sampled aerosol (Gordon et al., 1992; Reynolds et al., 2002; Spaan et al., 2007). Thus, our results suggest, without demonstrating it, the suitability of FG filters for measuring endotoxins in bioaerosols during work in a sewerage system. Expected health effects of the observed exposure levels There is no admitted occupational exposure limit (OEL) for endotoxins at international level. The health-based recommended OEL (HBROEL) proposed in the Netherlands of 50 EU m 3 and then adjusted to 200 EU m 3 (Heederik and Douwes, 1997; DECOS, 1998) are the widely used reference in the literature. The Dutch Expert Committee on Occupational Standards published a report proposing a new HBREOL of 90 EU m 3 (DECOS, 2010). In our study, the exposure measurements with CFC-FG were not excessively high compared with other occupational environments, but 17% exceeded 200 EU m 3 and 51% were over 90 EU m 3. The exposure levels we measured during sewer work were close to those reported in the wastewater treatment occupational environment where endotoxins are highly suspected to induce airway symptoms, general symptoms, and diarrhoea (Marth et al., 1997; Thorn and Kerekes, 2001; Hansen et al., 2003; Thorn and Beijer, 2004; Rylander, 2002, 2005). Such symptoms might be more prevalent in the population of workers we studied. Conclusions The sewer workers were exposed to endotoxins during their occupational tasks, especially the tasks involved in cleaning the pipes. In our exploratory study, cleaning the sedimentation chambers and the pipe galleries with a high-pressure water jet led to the highest levels of exposure. Thus, the exposure of the sewer workers to endotoxins tended to be the highest for tasks involving agitation of water and matter, and the method used to clean the pipes might be one of the determinants of the concentration of airborne endotoxins. However, the number of samples collected in the present descriptive study is too low for drawing definitive conclusions. The study only provides data regarding the level of exposure to endotoxins in underground sewer pipes and further exposure investigations are needed. As sewer workers are potentially exposed to a variety of biological agents other than endotoxins, future exposure investigations would include bacterial

10 Page 10 of 11 Exposure to Airborne Endotoxins among Sewer Workers and viral pathogens, mycotoxins, and other hazardous agents. The exposure levels measured in our study did not exceed 420 EU m 3 but such concentration levels of airborne endotoxins may cause adverse effects in sensitive workers. These results would be useful for designing larger exposures studies. Acknowledgements The authors would like to acknowledge Dr Christine Da Passano-Amiot from the worker health department of the city as well as Pascal Wild, Regis Colin, and Vincent Baudin from INRS for their valuable technical assistance during the study and their help for data analysis. References CEN (Comité Européen de Normalisation). (2003) Workplace atmosphere - determination of airborne endotoxins (CEN standard EN 14031). Brussels, Belgium: CEN. Chun DT, Bartlett K, Gordon T et al. (2006) History and results of the two inter-laboratory round robin endotoxin assay studies on cotton dust. Am J Ind Med; 49: Douwes J, Thorne P, Pearce N et al. (2003) Bioaerosol health effects and exposure assessment: progress and prospects. Ann Occup Hyg; 47: Duquenne P, Marchand G, Duchaine C. (2013) Measurement of endotoxins in bioaerosols at workplace: a critical review of literature and a standardization issue. Ann Occup Hyg; 57: Duquenne P, Simon X, Koehler V et al. (2012) Documentation of bioaerosol concentrations in an indoor composting facility in France. J Environ Monit; 14: Dutch Expert Committee on Occupational Standards (DECOS). (1998) Endotoxins: health based recommended recommended occupation exposure limit. Rijswijk, The Netherlands: The Health Council of the Netherlands, Publication No. 1988/03WGD. Dutch Expert Committee on Occupational Standards (DECOS). (2010) Endotoxins: health-based recommended occupational limit. The Hague, The Netherlands: The Health Council of the Netherlands, Publication No. 2010/04OSH. Gerardi MH, Zimmerman MC. (2005) Wastewater pathogens - wastewater microbiology series. Hoboken, NJ: John Wiley & Sons. 179 p. Gordon T, Galdanes K, Brosseau L. (1992) Comparaison of sampling media for endotoxin-contaminated aerosol. Appl Occup Environ Hyg; 7: Görner P, Fabries J-F, Duquenne P, et al. (2006) Bioaerosol sampling by a personal rotating cup sampler CIP 10-M. J Environ Monit; 8: Haas D, Unteregger M, Habib J et al. (2010) Exposure to bioaerosol from sewage systems. Water Air Soil Pollut; 207: Halstensen AS, Nordby KC, Wouters IM et al. (2007) Determinants of microbial exposure in grain farming. Ann Occup Hyg; 51: Hansen ES, Hilden J, Klausen H et al. (2003) Wastewater exposure and health--a comparative study of two occupational groups. Occup Environ Med; 60: Heederik D, Douwes J. (1997) Towards an occupational exposure limit for endotoxins? Ann Agric Environ Med; 4: Jeggli S, Steiner D, Joller H et al. (2004) Hepatitis E, Helicobacter pylori, and gastrointestinal symptoms in workers exposed to waste water. Occup Environ Med; 61: Karpinski C, Scheidt-Illig R, Wenzel E et al. (2000) Investigations of possible infection sources during sewer working. Gefahrst Reinhalt Luft; 60: Laitinen SK. (1999) Importance of sampling, extraction and preservation for quantification of biologically active endotoxin. Ann Agric Environ Med; 6: Laitinen SK, Kangas J, Husman K et al. (2001) Evaluation of exposure to airborne bacterial endotoxins and peptidoglycans in selected work environments. Ann Agric Environ Med; 8: Laitinen SK, Kangas J, Kotimaa M et al. (1994) Workers exposure to airborne bacteria and endotoxins at industrial wastewater treatment plants. Am Ind Hyg Assoc J; 55: Liebers V, Brüning T, Raulf-Heimsoth M. (2006) Occupational endotoxin-exposure and possible health effects on humans (review). Am J Ind Med; 49: Lundholm M, Rylander R. (1983) Work related symptoms among sewage workers. Brit J Ind Med; 40: Madsen AM. (2006) Airborne endotoxin in different background environments and seasons. Ann Agric Environ Med; 13: Marth E, Reinthaler FF, Schaffler K et al. (1997) Occupational health risks to employees of waste employees of waste treatment facilities. Ann Agric Environ Med; 4: Mueller-Anneling L, Avol E, Peters JM et al. (2004) Ambient endotoxin concentrations in PM10 from southern California. Environ Health Persp; 112: Neumann HD, Buxtrup M, Balfanz J et al. (2002) Belastungen durch biologische Arbeitsstoffe bei der Kanalreinigung. Gefahrst Reinhalt Luft; 9: Oppliger A, Hilfiker S, Vu Duc T. (2005) Influence of seasons and sampling strategy on assessment of bioaerosols in sewage treatment plants in Switzerland. Ann Occup Hyg; 49: Pfafflin JR, Ziegler EN. (2012) Encyclopedia of environmental science and engineering. 6th ed. New York, NY: CRC Press. Reynolds SJ, Thorne PS, Donham KJ et al. (2002) Comparison of endotoxin assays using agricultural dusts. Am Ind Hyg Ass J; 63: Richardson DB. (1995) Respiratory effects of chronic hydrogen sulfide exposure. Am J Ind Med; 28:

11 Exposure to airborne endotoxins among sewer workers Page 11 of 11 Rylander R. (1999) Health effects among workers in sewage treatment plants. Occup Environ Med; 56: Rylander R. (2002) Endotoxin in the environment--exposure and effects. J Endotox Res; 8: Rylander R. (2005) Health effects among workers in sewage treatment plants. Occup Environ Med; 56: Sanchez-Monedero MA, Aguilarb MI, Fenolla R et al. (2008) Effect of the aeration system on the levels of airborne microorganisms generated at wastewater treatment plants. Water Res; 42: Smit LAM, Spaan S, Heederik D. (2005) Endotoxin exposure and symptoms in wastewater treatment workers. Am J Ind Med; 48: Spaan S, Heederik DJJ, Thorne PS et al. (2007) Optimization of airborne endotoxin exposure assessment: effects of filter type, transport conditions, extraction solutions and storage of samples and extracts. Appl Environ Microbiol; 73: Spaan S, Smit LA, Eduard W et al. (2008) Endotoxin exposure in sewage treatment workers: investigation of exposure variability and comparison of analytical techniques. Ann Agric Environ Med; 15: Spaan S, Wouters IM, Oosting I et al. (2006) Exposure to inhalable dust and endotoxins in agricultural industries. J Environ Monit; 8: Thorn J, Beijer L, Jonsson T et al. (2002) Measurement strategies for the determination of airborne bacterial endotoxin in sewage treatment plants. Ann Occup Hyg; 46: Thorn J, Kerekes E. (2001) Health effects among employees in sewage treatment plants: a literature survey. Am J Ind Med; 40: Thorn T, Beijer M. (2004) Work-related symptoms and inflammation among sewage plant operatives. Int J Occup Environ Health; 10: Thorne PS, Perry SS, Saito R et al. (2010) Evaluation of the limulus amebocyte lysate and recombinant factor C assays or assessment of airborne endotoxin. Appl Environ Microbiol; 76: Thorne PS, Reynolds SJ, Milton DK et al. (1997) Field evaluation of endotoxin air sampling assay methods. Am Ind Hyg Assoc J; 58: Visser MJ, Spaan S, Arts HJJM et al. (2006) Influence of different cleaning practices on endotoxin exposure at sewage treatment plants. Ann Occup Hyg; 50:

Measurements of Airborne Fungal and Endotoxin Levels in Water-Damaged Buildings

Measurements of Airborne Fungal and Endotoxin Levels in Water-Damaged Buildings Measurements of Airborne Fungal and Endotoxin Levels in Water-Damaged Buildings Stella Manchun Tsai Chin S. Yang, Ph.D. Michael S. Crandall Member ASHRAE Member ASHRAE ABSTRACT Airborne fungi are often

More information

Source Water Protection Practices Bulletin Managing Sanitary Sewer Overflows and Combined Sewer Overflows to Prevent Contamination of Drinking Water

Source Water Protection Practices Bulletin Managing Sanitary Sewer Overflows and Combined Sewer Overflows to Prevent Contamination of Drinking Water United States Office of Water EPA 916-F-01-032 Environmental Protection (4606) July 2001 Agency Source Water Protection Practices Bulletin Managing Sanitary Sewer Overflows and Combined Sewer Overflows

More information

Analytical Method. Endotoxin analysis ANALYTICAL METHOD 332

Analytical Method. Endotoxin analysis ANALYTICAL METHOD 332 Analytical Method Endotoxin analysis ANALYTICAL METHOD 332 Applicability This method is used for analyzing endotoxins Standard(s) 1 No standard. Sampling system Glass fibre filters with three-section cassettes

More information

Sewerage Management System for Reduction of River Pollution

Sewerage Management System for Reduction of River Pollution Sewerage Management System for Reduction of River Pollution Peter Hartwig Germany Content page: 1 Introduction 1 2 Total emissions 3 3 Discharge from the wastewater treatment plants 4 4 Discharge from

More information

A Property Owner s Guide

A Property Owner s Guide The Operation and Maintenance of Domestic and Commercial Sewers A Property Owner s Guide KILDARE LOCAL AUTHORITIES WATER SERVICES DEPARTMENT TABLE OF CONTENTS Introduction 1. Why should I care? 2. What

More information

Water and Wastewater. Sample Collection and Analysis

Water and Wastewater. Sample Collection and Analysis Water and Wastewater Sample Collection and Analysis December 2011 Introduction Accurate testing of drinking water is crucial to maintaining the health and safety of Islanders who rely on this resource.

More information

WASTEWATER TREATMENT OBJECTIVES

WASTEWATER TREATMENT OBJECTIVES WASTEWATER TREATMENT OBJECTIVES The student will do the following: 1. Define wastewater and list components of wastewater. 2. Describe the function of a wastewater treatment plant. 3. Create a wastewater

More information

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS GEORGIA DEPARTMENT OF HUMAN RESOURCES ENVIRONMENTAL HEALTH SECTION A HOMEOWNERS GUIDE TO ON-SITE SEWAGE MANAGEMENT SYSTEMS March 12, 2002 WHAT IS AN ON-SITE SEWAGE MANAGEMENT SYSTEM An on-site sewage management

More information

Town of New Castle Utility Department Introduction

Town of New Castle Utility Department Introduction Town of New Castle Utility Department Introduction Town of New Castle Utility Department Mission Statement Our commitment is to ensure that our customers receive high quality water and wastewater treatment

More information

Collection and disposal of wastewater

Collection and disposal of wastewater 10 Collection and disposal of wastewater 10.1 Characteristics and hazards of wastewater from health-care establishments Wastewater from health-care establishments is of a similar quality to urban wastewater,

More information

Understanding Septic Tank Systems

Understanding Septic Tank Systems Understanding Septic Tank Systems Sewage and effluent can contain a variety of human disease-causing microorganisms and parasites. Disease can be spread to humans from this material by direct contact or

More information

Occupational/Industrial Hygiene Knowledge and Competency Requirements

Occupational/Industrial Hygiene Knowledge and Competency Requirements Occupational/Industrial Hygiene Knowledge and Competency Requirements I. PREFACE The International Occupational Hygiene Association's (IOHA's) National Accreditation Recognition (NAR) Committee holds a

More information

Oakland Unified San Jose Unified Stanford University Santa Ana Unified Newhall Unified Clovis Unified Merced Union High School Grossmont Union High

Oakland Unified San Jose Unified Stanford University Santa Ana Unified Newhall Unified Clovis Unified Merced Union High School Grossmont Union High Oakland Unified San Jose Unified Stanford University Santa Ana Unified Newhall Unified Clovis Unified Merced Union High School Grossmont Union High School District Industry Standards Damage Assessments

More information

This Questionnaire is divided into 8 sections referring to different capacity areas on the safe use of wastewater in agriculture:

This Questionnaire is divided into 8 sections referring to different capacity areas on the safe use of wastewater in agriculture: Annex - II Questionnaire to support the Capacity Development Needs Assessment In the framework of the Capacity Development Project on Safe Use of Wastewater 1 in Agriculture Phase I The Food and Agriculture

More information

Dedicated and calibrated pipettes can reduce variability. The Most Expensive Test is a Retest By Ruth Noe, UK and Ireland Sales Manager

Dedicated and calibrated pipettes can reduce variability. The Most Expensive Test is a Retest By Ruth Noe, UK and Ireland Sales Manager LALreview LAL REVIEW: PUBLISHED BY LONZA 2008 Issue 3 EDITOR S COLUMN What is the most expensive endotoxin test that you run in your QC lab? If I were to guess, I would say the retest. How often do you

More information

GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS

GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS PHARMACEUTICAL INSPECTION CONVENTION PHARMACEUTICAL INSPECTION CO-OPERATION SCHEME PI 032-2 8 January 2010 RECOMMENDATION GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE

More information

Asbestos exposure measurement investigation using analytical transmission electron microscopy (ATEM)

Asbestos exposure measurement investigation using analytical transmission electron microscopy (ATEM) Asbestos exposure measurement investigation using analytical transmission electron microscopy (ATEM) Summary of results and recommendations F. CLERC 1, C. EYPERT- BLAISON 1, M. GUIMON 2, A. ROMERO-HARIOT

More information

Causes of Bacteria in Water Samples 1

Causes of Bacteria in Water Samples 1 The Center at Keene: 149 Emerald Street, Keene NH 03431 Phone: (603) 357-2577 / Toll Free: (800) 760-4246 Fax: (603) 352-3899 Email: chem@eai-labs.com Causes of Bacteria in Water Samples 1 The purpose

More information

Advanced Treatment of Hazardous Wastes(1) Advanced Treatment of Hazardous Wastes(2) Advanced Environmental Chemistry. Design of Solid Waste Landfill

Advanced Treatment of Hazardous Wastes(1) Advanced Treatment of Hazardous Wastes(2) Advanced Environmental Chemistry. Design of Solid Waste Landfill Course Description (전체 개설 교과목 개요) Advanced Treatment of Hazardous Wastes(1) This course is concerned with the management of hazardous materials and wastes in depth. We will deal with the physico-chemical

More information

Why is a Dental Amalgam. Reduction Program Being Implemented Now? PROGRAM OVERVIEW TOPICS

Why is a Dental Amalgam. Reduction Program Being Implemented Now? PROGRAM OVERVIEW TOPICS SAN FRANCISCO DENTAL AMALGAM REDUCTION PROGRAM How Dental Offices Can Comply with Local Regulations for Office Wastewater Discharged Into the Sewer System SEPTEMBER 2003 PROGRAM OVERVIEW TOPICS Why is

More information

Managing the Risk of Legionnaires Disease in Vehicle Wash Systems

Managing the Risk of Legionnaires Disease in Vehicle Wash Systems Managing the Risk of Legionnaires Disease in Vehicle Wash Systems Guidance produced by a Water Management Society Working Party First published June 2008 Working Party members: John Alvey, David Bebbington,

More information

IUB Water Damage Restoration Guideline

IUB Water Damage Restoration Guideline IUB Water Damage Restoration Guideline Purpose The IUB Water Damage Restoration guideline was developed to ensure that all water intrusions are handled in a professional manner which includes the latest

More information

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Record MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Abandoned Gravity Private Combined Gravity Private Foul Gravity Private Surface Water Gravity Public Combined Gravity Public Foul Gravity Public

More information

Innovation and Progress in Water Treatment Technology

Innovation and Progress in Water Treatment Technology Innovation and Progress in Water Treatment Technology Degree of separation of ultrafiltration Summary of the various processes The water will be pressed through the between the raw water side and the filtrate

More information

Package Treatment Plant Policy and Procedure

Package Treatment Plant Policy and Procedure Package Treatment Plant Policy and Procedure PURPOSE There has been increased interest in the use of package treatment plants for new development proposals in the County. Current review procedures are

More information

septic systems What is a Septic System? How does a Septic System Work?

septic systems What is a Septic System? How does a Septic System Work? septic systems What is a Septic System? A septic system is a private sewage treatment system. They are common in rural areas where there are no municipal sewage pipes for homes, farms, businesses or other

More information

16. Storm water drainage

16. Storm water drainage 16. Storm water drainage There are three principal ways to dispose of rainwater from roofs, courtyards and paved areas: storm water sewers, soakaways and collection in storage tanks. Storm water sewers,

More information

RADON AND HEALTH. INFORMATION SHEET October 2002. What is radon and where does it come from?

RADON AND HEALTH. INFORMATION SHEET October 2002. What is radon and where does it come from? INFORMATION SHEET October 2 FINAL RADON AND HEALTH What is radon and where does it come from? Radon is a natural radioactive gas without odour, colour or taste. It cannot be detected without special equipment.

More information

RULE 8-8 - ORGANIC COMPOUNDS - WASTEWATER COLLECTION AND SEPARATION SYSTEMS

RULE 8-8 - ORGANIC COMPOUNDS - WASTEWATER COLLECTION AND SEPARATION SYSTEMS BAY AREA AIR QUALITY MANAGEMENT DISTRICT RULE 8-8 - ORGANIC COMPOUNDS - WASTEWATER COLLECTION AND SEPARATION SYSTEMS (ADOPTED: January 17, 1979) (AMENDED: November 1, 1989; October 6, 1993; June 15, 1994;

More information

Foul Drainage, systems and responsibility. Environmental Protection

Foul Drainage, systems and responsibility. Environmental Protection Foul Drainage, systems and responsibility Environmental Protection The Building Act 1984 The Building Act 1984 can be used to deal with unsatisfactory provision for drainage and appliances which are harmful

More information

FACT SHEET: Sewage Spills

FACT SHEET: Sewage Spills FACT SHEET: Sewage Spills Raw sewage contains biological agents such as bacteria, viruses, fungi and parasites that can cause serious illness and even death. There is also a risk from contamination with

More information

.5.1 MAINTENANCE AND PERIODIC INSPECTION OF DRAINAGE SYSTEMS

.5.1 MAINTENANCE AND PERIODIC INSPECTION OF DRAINAGE SYSTEMS .5.1 MAINTENANCE AND PERIODIC INSPECTION OF DRAINAGE SYSTEMS General Drainage systems should be inspected at regular intervals (not less than once a year) and, where necessary, thoroughly cleaned out at

More information

HUBER Vacuum Rotation Membrane VRM Bioreactor

HUBER Vacuum Rotation Membrane VRM Bioreactor HUBER Vacuum Rotation Membrane VRM Bioreactor VRM The rotating plate membrane for clean water applications. The future-oriented solution designed for the ever increasing requirements in wastewater treatment

More information

Environmental Science 101 Waste. Fall 2012. Lecture Outline: Terms You Should Know: Learning Objectives: Reading Assignment: Chlorinated.

Environmental Science 101 Waste. Fall 2012. Lecture Outline: Terms You Should Know: Learning Objectives: Reading Assignment: Chlorinated. Environmental Science 101 Waste Fall 2012 1 Lecture Outline: 17. SEWAGE DISPOSAL A. Sewage Handling B. Raw Sewage C. Wastewater Treatment Steps D. Individual Septic Systems E. Taking Stock Learning Objectives:

More information

YOUR SEPTIC SYSTEM UNCOVERED

YOUR SEPTIC SYSTEM UNCOVERED YOUR SEPTIC SYSTEM UNCOVERED By Raymond King District Director of Environmental Health It s underground where you can t see it. You don t really understand how it works. When it doesn t work your toilets

More information

SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS

SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS Published in Water and Waste Digest membrane issue, November 2008 Miroslav Colic; Chief Scientist, Clean Water Technology

More information

6. Principles of effective plumbing systems

6. Principles of effective plumbing systems 6. Principles of effective plumbing systems This chapter summarizes the aims and objectives of a good local plumbing system that is, the drinking-water supply that serves a building and the system for

More information

Homeowners and Home Buyers Guide to Wells and Private Sewage Systems

Homeowners and Home Buyers Guide to Wells and Private Sewage Systems Homeowners and Home Buyers Guide to Wells and Private Sewage Systems What every homeowner should know about living with a well and a private sewage system. YOUR ENVIRONMENTAL SYSTEMS Out of sight out of

More information

Appendix J IBC Biohazard Spill Management Plan

Appendix J IBC Biohazard Spill Management Plan OVERVIEW Prevention is the most important part of any spill management plan. Be sure to read and understand standard operating procedures (SOP s) and protocols for safe manipulation of biohazards before

More information

Routine Maintenance and Inspection

Routine Maintenance and Inspection THE CORPORATION OF THE VILLAGE OF WARFIELD POLICY TITLE: Sanitary Sewer Operations POLICY: #5435 PURPOSE: This policy is to provide the Village of Warfield s procedures for maintaining its sanitary sewer

More information

PROPAK AquaBio Complete Water Restoration Systems

PROPAK AquaBio Complete Water Restoration Systems PROPAK AquaBio Complete Water Restoration Systems Conserving natural resources and lowering operating expenses is no longer an option, it is a necessity. Water, sewer and discharge fees are continuing

More information

CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION

CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION Grease, So What's the Problem? Does your facility produce grease? All commercial cooking facilities generate Fats, Oil, and Grease

More information

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE 31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE Edited 21/12/01 Wyong Shire Council has many non sewered areas that

More information

www.dorsetforyou.com/pollution

www.dorsetforyou.com/pollution www.dorsetforyou.com/pollution Waste water is normally removed from your home via a system of underground pipes consisting of both drains and sewers. There is usually a separate system for rainwater and

More information

1. Identification of the substance/preparation and the company/undertaking

1. Identification of the substance/preparation and the company/undertaking MSDS Check-Direct CPE (Catalog no. 18-0080) 4-Color Compensation Set for Check-Direct CPE (Catalog no. 18-0070) 1. Identification of the substance/preparation and the company/undertaking Product name Supplier

More information

Chapter 2 Stormwater Pollution Prevention Plan (SWPPP) for Park Operations

Chapter 2 Stormwater Pollution Prevention Plan (SWPPP) for Park Operations SWPPP for Park Operations 2 Chapter 2 Stormwater Pollution Prevention Plan (SWPPP) for Park Operations Bordered by Lake Washington & Lake Sammamish, the City of Bellevue has more than 60 miles of streams,

More information

MAGB HEALTH, SAFETY AND ENVIRONMENT GROUP POLLUTION INCIDENT RESPONSE PLAN

MAGB HEALTH, SAFETY AND ENVIRONMENT GROUP POLLUTION INCIDENT RESPONSE PLAN MAGB HEALTH, SAFETY AND ENVIRONMENT GROUP POLLUTION INCIDENT RESPONSE PLAN SCOPE: This guidance sets out best practice for producing a Pollution Incident Response Plan to deal with an environmental incident

More information

Managing Floor Drains and Flammable Traps

Managing Floor Drains and Flammable Traps Managing Floor Drains and Flammable Traps Contents: Problem... 1 Solution... 2 Maintenance... 2 Waste Management Options... 2 For More Information... 4 BMP Chart... 5 This fact sheet discusses recommended

More information

http://www.cdc.gov/od/ohs/biosfty/bmbl4/b4ai.htm Office of Health and Safety (OHS) BMBL Appendix I

http://www.cdc.gov/od/ohs/biosfty/bmbl4/b4ai.htm Office of Health and Safety (OHS) BMBL Appendix I Office of Health and Safety (OHS) References BMBL Appendix I Guidelines for Work With Toxins of Biological Origin Biosafety Documents BMBL Table of Contents In recognition of the growing number of microbiological

More information

SEWER LINE CLEANING, DEBRIS AND GREASE REMOVAL, DEBRIS AND GREASE DISPOSAL

SEWER LINE CLEANING, DEBRIS AND GREASE REMOVAL, DEBRIS AND GREASE DISPOSAL SEWER LINE CLEANING, DEBRIS AND GREASE REMOVAL, DEBRIS AND GREASE DISPOSAL This contract shall consist of cleaning, debris and grease disposal, of 7048 (+/-) feet of sewer pipe in accordance with the bid

More information

The Trend in Airborne Asbestos Concentrations at Plants Manufacturing Asbestos-Containing Products in Japan

The Trend in Airborne Asbestos Concentrations at Plants Manufacturing Asbestos-Containing Products in Japan Industrial Health 2001, 39, 127 131 Original Article The Trend in Airborne Asbestos Concentrations at Plants Manufacturing Asbestos-Containing Products in Japan Koji YOSHIZUMI 1 *, Hajime HORI 2, Toshihiko

More information

ON-SITE WASTEWATER TREATMENT SYSTEMS ACT

ON-SITE WASTEWATER TREATMENT SYSTEMS ACT ON-SITE WASTEWATER TREATMENT SYSTEMS ACT Revised and reproduced by the Colorado Department of Public Health and Environment June, 2012 (PLEASE NOTE: This is an unofficial copy of this statute. The official

More information

SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES

SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES 1.0 GENERAL 1.1 Article 12 of the Suffolk County Sanitary Code requires that toxic/hazardous material

More information

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material Revised November 21, 2013 Application Code of Practice Where asbestos is present or believed to be present in a workplace

More information

Water should be removed as soon as possible once the safety of the structure has been verified.

Water should be removed as soon as possible once the safety of the structure has been verified. FACT SHEET Posted October 18 2005 Check List for Infection Control Concerns when Reopening Healthcare Facilities Closed due to Extensive Water and Wind Damage Prior to opening a healthcare facility that

More information

DATA QUALITY OBJECTIVES

DATA QUALITY OBJECTIVES The Wastewater Treatment Plant Operators Guide to Biosolids Sampling Plans CHAPTER 5 DATA QUALITY OBJECTIVES Goals of the Sampling Plan ESSENTIAL ELEMENTS OF A SAMPLING PLAN Description of the Facility

More information

Type of Sewer Systems. Solomon Seyoum

Type of Sewer Systems. Solomon Seyoum Type of Sewer Systems Solomon Seyoum 0 Learning objectives Upon completion of this lecture, the participants will be able to differentiate between types of sewer systems and discuss different aspects of

More information

GUIDELINES FOR MANAGEMENT AND HANDLING OF SPENT MYCELIUM FROM BULK DRUG INDUSTRY

GUIDELINES FOR MANAGEMENT AND HANDLING OF SPENT MYCELIUM FROM BULK DRUG INDUSTRY GUIDELINES FOR MANAGEMENT AND HANDLING OF SPENT MYCELIUM FROM BULK DRUG INDUSTRY MAHARASHTRA POLLUTION CONTROL BOARD Kalpataru Point, Sion (E), Mumbai 400 022. E-mail : mpcb@vsnl.net Web site : http://mpcb.mah.nic.in

More information

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems PACKAGE SEWAGE TREATMENT SYSTEM Clearwater treatment plants are ideal for single houses and employ the well proven aerobic biological

More information

Stachybotrys chartarum a mold that may be found in water-damaged homes

Stachybotrys chartarum a mold that may be found in water-damaged homes Stachybotrys chartarum a mold that may be found in water-damaged homes November 2000 Environmental Health Investigations Branch California Department of Health Services Stachybotrys chartarum ecology Stachybotrys

More information

Basics of UV Disinfection

Basics of UV Disinfection Local Section Seminar Basics of UV Disinfection April 17, 2014 Joseph Moore, P.E. DuBois-Cooper Associates, Inc. 1 Presentation Outline Basics of Ultraviolet (UV) Disinfection Components of UV Disinfection

More information

Standard Operating Procedure for Cleaning Nylon Filters Used for the Collection of PM 2. 5 Material

Standard Operating Procedure for Cleaning Nylon Filters Used for the Collection of PM 2. 5 Material PM 2.5 Nylon Filter Cleaning Date: August 25,2009 Page I of8 Standard Operating Procedure for Cleaning Nylon Filters Used for the Collection of PM 2. 5 Material Environmental and Industrial Sciences Division

More information

Drainage and Grease Management for the Commercial Kitchen

Drainage and Grease Management for the Commercial Kitchen Drainage and Grease Management for the Commercial Kitchen ACO. The future of drainage. The ACO system chain provides drainage solutions to meet the needs of tomorrow s food service facilities. Hostile

More information

California Wastewater

California Wastewater Abridged Edition L A Y P E R S O N S G U I D E T O California Wastewater Prepared by the Water Education Foundation Contents The Layperson s Guide to California Wastewater is prepared and distributed by

More information

Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS

Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS The evolution continues in decentralised wastewater technology... The Process Decentralised wastewater treatment systems are defined

More information

RULE 1102. DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

RULE 1102. DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE (Adopted January 6, 1978)(Amended August 3, 1979)(Amended July 11, 1980) (Amended August 3, 1990)(Amended December 7, 1990) (Amended November 17, 2000) RULE 1102. DRY CLEANERS USING SOLVENT OTHER THAN

More information

New Protocol for the Assessment and Remediation of Indoor Mold Growth

New Protocol for the Assessment and Remediation of Indoor Mold Growth New Protocol for the Assessment and Remediation of Indoor Mold Growth Ed Light 1,*, Roger Gay 1 and James Bailey 1 1 Building Dynamics, LLC, Ashton MD (USA) *Corresponding email: ELight@building-dynamics.com

More information

Contaminants of Concern Exposure Pathways

Contaminants of Concern Exposure Pathways Table of Contents Purpose... 1 Background... 1 Contaminants of Concern... 2 Exposure Pathways... 2 Community Health Concerns... 3 Recommendations... 3 Pubic Health Action Plan... 3 Figure 1 : Site Map...

More information

DOMESTIC WASTEWATER SYSTEMS

DOMESTIC WASTEWATER SYSTEMS Environmental PROTECTION Systems DOMESTIC WASTEWATER SYSTEMS Highest quality sewage treatment systems from the name you can trust Hynds Aerated Wastewater Systems Hynds Lifestyle Systems are an elite range

More information

British Columbia Institute of Technology. BCIT Safety Manual ASBESTOS MANAGEMENT

British Columbia Institute of Technology. BCIT Safety Manual ASBESTOS MANAGEMENT BCIT Safety Manual Contents 1. Purpose... 3 2. Definitions... 3 2.1 Asbestos... 3 2.2 Asbestos Containing Material (ACM)... 3 2.3 Friable Material... 3 2.4 Low Risk Work Activity... 3 2.5 Moderate Risk

More information

CSA Z317-13-12 Infection Control during Construction, Renovation and Maintenance of Health Care Facilities Overview and Case Studies

CSA Z317-13-12 Infection Control during Construction, Renovation and Maintenance of Health Care Facilities Overview and Case Studies CSA Z317-13-12 Infection Control during Construction, Renovation and Maintenance of Health Care Facilities Overview and Case Studies Grant Rogers, BSc. Principal 1 North West Environmental Group Industrial

More information

How To Monitor Toxicity In Water

How To Monitor Toxicity In Water 1 WORKSHOP AND OPEN TECHNICAL MEETING WITH A VERIFICATION EXERCISE: Towards a European ETV Environmental Technology Verification System. Barcelona. 20-22 February 2008 AUTOMATED MICROBIAL BIOSENSORS FOR

More information

Health Consultation MID-AMERICA TANNING COMPANY SERGEANT BLUFF, WOODBURY COUNTY, IOWA EPA FACILITY ID: IAD085824688 FEBRUARY 17, 2005

Health Consultation MID-AMERICA TANNING COMPANY SERGEANT BLUFF, WOODBURY COUNTY, IOWA EPA FACILITY ID: IAD085824688 FEBRUARY 17, 2005 Health Consultation MID-AMERICA TANNING COMPANY SERGEANT BLUFF, WOODBURY COUNTY, IOWA EPA FACILITY ID: IAD085824688 FEBRUARY 17, 2005 U.S. DEPARTMENT OF HEALTH AND HUMAN SERVICES Public Health Service

More information

analyzing small data sets

analyzing small data sets Review of Lognormal Statistics and Review of Lognormal Statistics and analyzing small data sets Review of IH Statistics I. Lognormal distribution II. III. IV. Sample 95 th percentile UCL for the sample

More information

KEY CAL/OSHA STANDARDS THAT APPLY TO MOST EMPLOYERS

KEY CAL/OSHA STANDARDS THAT APPLY TO MOST EMPLOYERS KEY CAL/OSHA STANDARDS THAT APPLY TO MOST EMPLOYERS FACTSHEET 1 Below are some key Cal/OSHA standards that apply to most employers: A. INJURY AND ILLNESS PREVENTION PROGRAM STANDARD (Title 8 California

More information

Chapter 5. INFECTION CONTROL IN THE HEALTHCARE SETTING

Chapter 5. INFECTION CONTROL IN THE HEALTHCARE SETTING Chapter 5. INFECTION CONTROL IN THE HEALTHCARE SETTING INTRODUCTION This chapter addresses infection control measures and practices in the healthcare setting and provides guidance to healthcare facilities

More information

JIANGSU CARTMAY INDUSTRIAL CO.,LTD www.labfurniture.asia mail: info@labfurniture.asia

JIANGSU CARTMAY INDUSTRIAL CO.,LTD www.labfurniture.asia mail: info@labfurniture.asia The basic layout, the main functions and instrumentation concept of micro Inspection Division laboratory, 1, Virology Laboratory 1. Functions: for the city to monitor the prevalence of HIV disease, dealing

More information

Environment, Health & Safety Services Policy

Environment, Health & Safety Services Policy 1.0 Purpose: The purpose of this document is to outline the management of lead containing materials at UB. The information presented in this document represents minimum safety requirements. 2.0 Scope:

More information

On Site Treatment Systems

On Site Treatment Systems On Site Treatment Systems Introduction In cases where houses require to be located in the countryside,(i.e. where no sewerage is available),it is necessary to provide a specific on-site treatment system

More information

Civil Engineering Sector Labour-Management Health and Safety Committee

Civil Engineering Sector Labour-Management Health and Safety Committee PROCEDURE FOR THE STORAGE AND HANDLING OF FUEL ON CONSTRUCTION SITES Civil Engineering Sector Labour-Management Health and Safety Committee July 2008 PROCEDURE FOR THE STORAGE AND HANDLING OF FUEL ON CONSTRUCTION

More information

A build-up of dirt and decaing organic matter is undesirable in koi ponds.

A build-up of dirt and decaing organic matter is undesirable in koi ponds. Hydrogen Sulphide in Koi Ponds A build-up of dirt and decaing organic matter is undesirable in koi ponds. KOISA No. 33 June 010 Hydrogen Sulphide Gas (HS) and Koi Ponds A build up of dirt and decaying

More information

Spill Prevention, Control & Cleanup SC-11

Spill Prevention, Control & Cleanup SC-11 Objectives Cover Contain Educate Reduce/Minimize Product Substitution Description Spills and leaks, if not properly controlled, can adversely impact the storm drain system and receiving waters. Due to

More information

GUIDANCE FOR DEVELOPMENT OF SPILL AND SLUG PREVENTION CONTROL PLANS AND FACILITIES FOR THE CITY OF ATTLEBORO SEWER USERS

GUIDANCE FOR DEVELOPMENT OF SPILL AND SLUG PREVENTION CONTROL PLANS AND FACILITIES FOR THE CITY OF ATTLEBORO SEWER USERS Company Name: Address: The City of Attleboro s Rules and Regulations for the use of Wastewater Facilities require each user to provide protection from accidental discharge of prohibited materials and substances

More information

SECTION 6. The Codex code of practice on good animal feeding

SECTION 6. The Codex code of practice on good animal feeding SECTION 6 The Codex code of practice on good animal feeding 60 The Codex code of practice on good animal feeding SECTION 6 61 CODE OF PRACTICE ON GOOD ANIMAL FEEDING CAC/RCP 54-2004 SECTION 1. INTRODUCTION

More information

DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS

DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS Phase I MS4 permits require continuous updating of the stormwater system inventory owned and operated by the MS4. They also include inspection

More information

SEWER CLEANING, INSPECTION AND ASSESSMENT

SEWER CLEANING, INSPECTION AND ASSESSMENT 3.1 OVERVIEW Chapter 3 SEWER CLEANING, INSPECTION AND ASSESSMENT Preventive maintenance protects the investment of the sanitary sewer collection system infrastructure. Higher frequency cleaning of gravity

More information

WATER AND HEALTH Vol. I - Goals of Water Treatment And Disinfection: Reduction In Morbidity and Mortality - Pierre Payment

WATER AND HEALTH Vol. I - Goals of Water Treatment And Disinfection: Reduction In Morbidity and Mortality - Pierre Payment GOALS OF WATER TREATMENT AND DISINFECTION: REDUCTION IN MORBIDITY AND MORTALITY Pierre INRS- Institut Armand-Frappier, Institut National de la recherche scientifique, Canada Keywords: drinking water, treatment

More information

Liabilities of Vented Crawl Spaces And Their Impacts on Indoor Air Quality in Southeastern U.S. Homes

Liabilities of Vented Crawl Spaces And Their Impacts on Indoor Air Quality in Southeastern U.S. Homes Liabilities of Vented Crawl Spaces And Their Impacts on Indoor Air Quality in Southeastern U.S. Homes Jonathan Coulter, Bruce Davis, Cyrus Dastur, Melissa Malkin-Weber and Tracy Dixon Advanced Energy,

More information

National Precast Concrete Association

National Precast Concrete Association National Precast Concrete Association NOTES 1. This manual does not claim or imply that it addresses any safety-related issues associated with its use. Operation and maintenance of precast concrete grease

More information

1.0 What Are the Purpose and Applicability of Performance Specification 11?

1.0 What Are the Purpose and Applicability of Performance Specification 11? While we have taken steps to ensure the accuracy of this Internet version of the document, it is not the official version. Please refer to the official version in the FR publication, which appears on the

More information

Technical Information Paper No. 37-032-0415

Technical Information Paper No. 37-032-0415 How to Dispose of Clinical Laboratory Equipment Effluent Technical Information Paper No. 37-032-0415 1. WHAT IS THE ISSUE? Federal, state and local regulations will require generators of laboratory equipment

More information

The course and qualification may be taken as a stand-alone certificate, or as part of a wider course of training.

The course and qualification may be taken as a stand-alone certificate, or as part of a wider course of training. Level 2 Foundation Award in Food Hygiene January 2016 Guided Learning Hours 7 Total Qualification Time 7 Ofqual Qualification Number 601/8306/8 Description: The RSPH Foundation Award in Food Hygiene is

More information

How To Deal With Asbestos In Minster Of Minsteria

How To Deal With Asbestos In Minster Of Minsteria RELATED TO EXPOSURE TO ASBESTOS AT WORK [S.L.424.23 1 SUBSIDIARY LEGISLATION 424.23 RELATED TO EXPOSURE TO ASBESTOS AT WORK REGULATIONS LEGAL NOTICE 323 of 2006. 15th December, 2006 1. (1) The title of

More information

Federation of European Heating, Ventilation and Air-conditioning Associations

Federation of European Heating, Ventilation and Air-conditioning Associations Federation of European Heating, Ventilation and Air-conditioning Associations Address: Rue Washington 40 1050 Brussels Belgium www.rehva.eu info@rehva.eu Tel: +32 2 514 11 71 Fax: +32 2 512 90 62 Use of

More information

Legionnaires disease: Technical guidance Part 3: The control of legionella bacteria in other risk systems

Legionnaires disease: Technical guidance Part 3: The control of legionella bacteria in other risk systems Legionnaires disease: Technical guidance Part 3: The control of legionella bacteria in other risk systems This guidance for dutyholders, including employers, those in control of premises and those with

More information

BY-LAW CONCERNING DISCHARGES AT PURIFICATION WORKS ON THE TERRITORY OF THE URBAN AGGLOMERATION OF MONTRÉAL

BY-LAW CONCERNING DISCHARGES AT PURIFICATION WORKS ON THE TERRITORY OF THE URBAN AGGLOMERATION OF MONTRÉAL VILLE DE MONTRÉAL BY-LAW RCG 08-041 BY-LAW CONCERNING DISCHARGES AT PURIFICATION WORKS ON THE TERRITORY OF THE URBAN AGGLOMERATION OF MONTRÉAL In view of article 17 of the by-law entitled Règlement sur

More information

Risk assessment and occupational safety and health protection in construction work on contaminated sites

Risk assessment and occupational safety and health protection in construction work on contaminated sites Risk assessment and occupational safety and health protection in construction work on contaminated sites Dipl.-Geol. A. Feige-Munzig BG BAU Prävention Germany BG Berufsgenossenschaft?? Statutory Accident

More information

MagExtractor -Genome-

MagExtractor -Genome- Instruction manual MagExtractor-Genome-0810 F0981K MagExtractor -Genome- NPK-101 100 preparations Store at 4 C Contents [1] Introduction [2] Components [3] Materials required [4] Protocol 1. Purification

More information

CERTIFIED SEPTIC EVALUATION PREPARED FOR MATT HASHEM 1673 MT. MAJOR HWY, ALTON, NH 03810

CERTIFIED SEPTIC EVALUATION PREPARED FOR MATT HASHEM 1673 MT. MAJOR HWY, ALTON, NH 03810 DATE: May 31, 2013 N.H. LICENSED DESIGNER OF SUBSURFACE DISPOSAL SYSTEMS 216 Hill Road Phone & Fax: 934-6206 Franklin, NH 03235 Cell: 393-3085 CERTIFIED SEPTIC EVALUATION PREPARED FOR MATT HASHEM 1673

More information

El Paso Water Utilities Public Service Board. Application for Renewal Industrial Wastewater Discharge Permit

El Paso Water Utilities Public Service Board. Application for Renewal Industrial Wastewater Discharge Permit El Paso Water Utilities Public Service Board Application for Renewal Industrial Wastewater Discharge Permit Application for Renewal for Industrial Wastewater Discharge Permit must be completed and submitted

More information