HELPY L300 START-UP GUIDE

Size: px
Start display at page:

Download "HELPY L300 START-UP GUIDE"

Transcription

1 HELPY L300 START-UP GUIDE

2 HELPY L300 ALARM SYSTEM CONFIGURATION: OR - HELPY L300 - Active handsfree terminal to be placed behind COP - Passive handsfree terminal with emergency pushbutton to be placed on the cartop - Active handsfree terminal with emergency pushbutton to be placed on the shaft-pit - Telephone handset to be placed in the machine room / lift controller - GSM200 gateway GSM200 (5IG-004) - UNIVERSAL GSM500 GC GATEWAY OR ANALOG EXTERNAL LINE GSM500 GC (5CT-061) OR 5HV-004 CAR-TOP BEHIND COP 5HV-001 SHAFT-PIT Telephone handset (4TS-101) 5HV-003

3 CONNECTING A GSM GATEWAY INSERTING THE SIM CARD you insert the SIM card. GSM200 GSM500 Press the plastic case to open by using a screwdriver. Insert / replace the SIM card by acting on the SIM CARD holder. GSM200 GSM500 SUPPLYING THE UNIVERSAL GATEWAY GSM500 GC PLUG RJ11 telephone line Adapter 230 Vac / 12Vdc Telephone line External + 12 Vdc For connection of the external power supply and the telephone line, please use either the dedicated plugs or the built-in screw terminals. TO CONNECT THE BUILT-IN BATTERY PACK, PLEASE INSERT THE CONNECTOR INTO THE DEDICATED SOCKET - ONLY FOR GSM500 GC VERSION-

4 REMOVING THE COVER L300 REMOVE THE SCREW OPEN THE CASE CONNECTING THE GSM200 (5IG-004) RJ45 RJ45 To connect the GSM200 gateway to the autodialer HELPY L300, please use the cable RJ45. The GSM200 is directly supllied by the autodialer. IMPORTANT: Dial 661 to program GSM200 line AND: SET THE MINIJUMPER AS SHOWN IN THE PICTURE JP 12 CONNECTING THE GSM500 GC (5CT-061) OR ANALOG EXTERNAL LINE The Universal gateway GSM500 or the PSTN line must be connected to the LTI terminal block. IMPORTANT: Dial 660 to program PSTN line or GSM500 line AND: LEAVE THE JUMPERS AS SET BY FACTORY DEFAULT JP 12

5 CONNECTING POWER SUPPLY 230 Vac FAST-ON PLUG REMOVE THE PROTECTION OF THE 230 Vac TERMINAL BLOCKS TO CONNECT THE POWER SUPPLY. 7BA CONNECTING ACTIVE HANDSFREE TERMINAL (BEHIND COP) AND PUSHBUTTON CONNECTING ACTIVE HANDSFREE TERMINAL 1. Connect the terminal block vv1 - of the autodialer to the terminal block - of the handsfree terminal 2. Connect the terminal block vv1 + of the autodialer to the terminal block + of the handsfree terminal CONNECTING THE DOUBLE-CONTACT ALARM PUSHBUTTON 1. Connect the terminal block VV1 - to any of the contacts of the alarm pushbutton 2. Connect the terminal block AL1 of the autodialer to the other contact of the alarm pushbutton AL1 - Cabin Pushbutton B A - +

6 CONNECTING PASSIVE HANDSFREE TERMINAL WITH PUSHBUTTON (CAR-TOP) 1. Connect the terminal block B of the passive handsfree terminal to the terminal block B of the active handsfree terminal 2.Connect the terminal block A of the passive handsfree terminal to the terminal block A of the active handsfree terminal 3. Connect the terminal block - of the passive handsfree terminal to the terminal bloc k - of the active handsfree terminal 4. Connect one of the passive handsfree terminal s pushbutton contact to the terminal block - of the passive handsfree terminal 5. Connect the free pushbutton contact to the terminal block AL1 of the autodialer + - A B To connect the passive handsfree terminal and the active handsfree terminal please use a shielded cable. B A - + 5HV-004 PASSIVE HANDSFREE TERMINAL WITH PUSHBUTTON 5HV-001 ACTIVE HANDSFREE TERMINAL CONNECTING PASSIVE HANDSFREE TERMINAL WITH PUSHBUTTON (SHAFT-PIT) 1. Connect the terminal block + of the active handsfree teminal to the terminal block VV2 + of the autodialer 2. Connect the terminal block - of the active handsfree teminal to the terminal block VV2 - of the autodialer 3. Connect the terminal block - of the active handsfree terminal to one of the handsfree pushbutton contacts 4. Connect the free pushbutton contact to the terminal block AL2 of the autodialer B A - + 5HV-003 ACTIVE HANDSFREE TERMINAL WITH PUSHBUTTON

7 CONNECTING THE TELEPHONE IN THE MACHINE ROOM AND THE SIGNALLING LEDs 1. Connect the plug RJ11 to the telephone in the machine room 2. Connect the conductors to the terminal block TEL of the autodialer NOTE: To connect the telephone it is possible to use also the RJ11 plug, located above the terminal blocks. 3. Connect the Alarm sent Led to the terminal block AI and to the terminal block - of the autodialer. 470 Ohm 1/2 W 470 Ohm 1/2 W 4. Connect the Alarm recaived Led to the terminal block AR and to the terminal block - of the autodialer. Ar Ai NOTE: Make sure that the existing pushbuttons lights are equipped with internal resistors. RJ11

MusicTel-60. Music on-hold SYSTEM. Installation Manual

MusicTel-60. Music on-hold SYSTEM. Installation Manual MusicTel-60 Music on-hold SYSTEM Installation Manual Table of Contents INTRODUCTION... 1 DESCRIPTION... 2 PHYSICAL DESCRIPTION... 2 UNPACKING... 2 INSTALLATION... 3 RECORDING INSTRUCTIONS... 3 PHYSICAL

More information

FWT-8848 GSM (GATEWAY) USER S MANUAL

FWT-8848 GSM (GATEWAY) USER S MANUAL FWT-8848 GSM (GATEWAY) USER S MANUAL COPYRIGHT -2009 1 ST VERSION 1 1,General Description: FWT-8848 is a GSM to Analog Converter(single port,insert 1 sim card only), the device can produce a FXS line to

More information

Ericsson W25. Mobile Networks. Quick Installation Guide

Ericsson W25. Mobile Networks. Quick Installation Guide Ericsson W25 Fixed Wireless Terminal for WCDMA/HSDPA Mobile Networks Quick Installation Guide Table of Contents INTRODUCTION... 3 Package Contents... 3 Requirements... 3 INSTALLATION... 4 Unit Preparation...

More information

GSM1000 The Orchid Mobile Gateway. Benefits & Feature List

GSM1000 The Orchid Mobile Gateway. Benefits & Feature List GSM1000 The Orchid Mobile Gateway. Benefits & Feature List The Gateway to cost savings A Fixed Cellular terminal with Full Call Divert - getting the most Benefits from your mobile phone s free minutes

More information

How To Program An Autodialer

How To Program An Autodialer GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX INSTALLATION INSTRUCTIONS Step 1. Determine the position for the Hands-free phone in the elevator phone

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

Autodialler. Installation & Programming Guide HYL004. Please read these instructions before you start the installation. Installation.

Autodialler. Installation & Programming Guide HYL004. Please read these instructions before you start the installation. Installation. Autodialler HYL004 Installation & Programming Guide Features Please read these instructions before you start the installation LCD Display Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

GSM ALARM SYSTEM GCM 8

GSM ALARM SYSTEM GCM 8 GSM ALARM SYSTEM GCM 8 GCM8 is a universal alarm system. It can be used as alarm system in vehicles, apartments, houses etc. Also GCM8 can be used for opening garage doors. GCM8 is designed to work with

More information

Product Guide CM-Relay

Product Guide CM-Relay Product Guide CM-Relay www.theclimate.co.uk tel: 01491 410913 The Climate, Badgers Bank, Harpsden, Henley-on-Thames, Oxfordshire RG9 4HL. Overview CM-Relay combines climate monitoring with remote relay

More information

EMBEDDED ACCESS CONTROL Hardware Installation Guide

EMBEDDED ACCESS CONTROL Hardware Installation Guide EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel

More information

TSA3100-EU LIFT EMERGENCY ALARM

TSA3100-EU LIFT EMERGENCY ALARM TSA3100-EU LIFT EMERGENCY ALARM TECHNICAL MANUAL. The TSA3100-EU is the european version of the TSA3100 adopted to the CTR21 teleapproval (TBR21 specifications) and the EN-81 lift regulation and its interpretation

More information

8 Channel Status Input Panel model SIP-8

8 Channel Status Input Panel model SIP-8 Description The Sine Systems model SIP-8 Status Input Panel is to be used with the RFC-1/B Remote Facilities Controller. It consists of a long PC board mounted on a 1.75 inch (1U) rack panel. The SIP-8

More information

GSMPBX version 1.3 Datasheet

GSMPBX version 1.3 Datasheet GSMPBX version.3 Datasheet Document Rev.:.3 Revision Date: 23.03.203 (preliminary data) Figure - GSMPBX Introduction The GSMPBX is designed to commute phone calls between a cellular network (GSM) and the

More information

Model PBX 206 Programming & User Guide

Model PBX 206 Programming & User Guide Model PBX 206 Programming & User Guide www.orchid-telecom.com V1.1 1 Contents Page Programming & Set Up General Information 3 Incoming Ringing 3 Do you Have 1 or 2 exchange Lines? 3 Auto Attendant (DISA)

More information

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE September 2004 Prepared by: Integrated Systems Division The Sutron Corporation 21300 Ridgetop Circle Sterling, VA 20166 Copyright 2004

More information

FältCom ECII Flex Manual. Version: 0.2.4-C Updated: 2010-12-15. 162187 Manual FältCom ECII Flex Page 1 of 42

FältCom ECII Flex Manual. Version: 0.2.4-C Updated: 2010-12-15. 162187 Manual FältCom ECII Flex Page 1 of 42 FältCom ECII Flex Manual Version: 0.2.4-C Updated: 2010-12-15 162187 Manual FältCom ECII Flex Page 1 of 42 162187 Manual FältCom ECII Flex Page 2 of 42 Table of contents 1 NOTES... 5 2 COPYRIGHT... 5 3

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit

More information

LINE POWERED ADA TELEPHONE USER S MANUAL Use With Part Numbers 11-580, 11-581, 11-582, 11-583, 11-585,11-586 and 11-589

LINE POWERED ADA TELEPHONE USER S MANUAL Use With Part Numbers 11-580, 11-581, 11-582, 11-583, 11-585,11-586 and 11-589 LINE POWERED ADA TELEPHONE USER S MANUAL Use With Part Numbers 11-580, 11-581, 11-582, 11-583, 11-585,11-586 and 11-589 6200 Brent Drive, Toledo, Ohio 43611 Phone: 800-837-1066 Fax: 419-729-5764 Email:

More information

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun) USER MANUAL MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun) An ISO-9001 Certified Company Part #07M460-E Doc. #019021UE Revised 02/23/00 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301)

More information

Cabling Specifications

Cabling Specifications APPENDIX A This appendix provides cabling and pinout information for feature cards on the Cisco AS5350XM and Cisco AS5400XM universal gateways. It contains the following sections: 2-Port and 4-Port T1

More information

GSM Autodialer Professional GJD700 Speech & Text Autodialer

GSM Autodialer Professional GJD700 Speech & Text Autodialer Text Edit message GSM Autodialer Professional GJD700 Speech & Text Autodialer Introduction The GSM Autodialer Professional works in conjunction with standard alarm systems and makes use of your preferred

More information

T E L ST R A S NEXT G INTEGRATED D E V I C E OFFER

T E L ST R A S NEXT G INTEGRATED D E V I C E OFFER T E L ST R A S NEXT G INTEGRATED D E V I C E OFFER Q U ICK START USER GUIDE Please retain the original packaging prov ided for the return of the unit HOW TO M A N UA LLY S E T U P T H E VOICE AND BROADB

More information

Least Cost Router Dialer / Calling Card Auto Dialer Manual

Least Cost Router Dialer / Calling Card Auto Dialer Manual Least Cost Router Dialer / Calling Card Auto Dialer Manual Installation & Programming Manual Installation Easy Plug-in installation (Free to move from phone to phone) 1. Plug your telephone line phone

More information

TOA INTERCOM SYSTEM. TOA Corporation OPERATING INSTRUCTIONS

TOA INTERCOM SYSTEM. TOA Corporation OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS TOA INTERCOM SYSTEM INTERCOM STATION HF-250M Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend you to keep this manual

More information

Tele Eye DT Series. Installation Guide. Dialup CCTV Transmitter DT-103G DT-103P DT-103D

Tele Eye DT Series. Installation Guide. Dialup CCTV Transmitter DT-103G DT-103P DT-103D Tele Eye DT Series Dialup CCTV Transmitter DT-103G DT-103P DT-103D Installation Guide Notice: Signal Communications Limited reserves the right to make improvements to the product described in this manual

More information

Model 70A00-1. GSM Cellular Communications Center

Model 70A00-1. GSM Cellular Communications Center Home Automation, Inc. Model 70A00-1 GSM Cellular Communications Center Operation Manual Document Number 70I00-1 Rev A August, 2009 Contents Description... 1 Use with security systems...1 Everyday use...2

More information

D45. SySTEm. ThE high-performance

D45. SySTEm. ThE high-performance D45 ThE high-performance SySTEm Security monitoring system with digital BUS technologies High efficiency system and quick installation for both backbone and riserdevicesthankstotheuse of cat.5e UTP cables

More information

Home and Small Business 308 Mini-PABX Start up guide

Home and Small Business 308 Mini-PABX Start up guide Home and Small Business 308 Mini-PABX Start up guide We would like to thank you for purchasing the Mini-PABX Kit; it is a very powerful solution for small business and home office scenarios. This guide

More information

GLENSOUND ELECTRONICS LTD

GLENSOUND ELECTRONICS LTD GLENSOUND ELECTRONICS LTD GS-MPI004 GSM Beltpack Unit & GS-MPI005 GSM Subrack Unit DATE 25/03/08 ISSUE No. 2 HANDBOOK CONTENTS DESCRIPTION PAGE No. Panel Drawings & Block Diagram...2 GS-MPI004 Front &

More information

In regard to calculating system power requirements, refer to DBK Basics located near the front of this manual.

In regard to calculating system power requirements, refer to DBK Basics located near the front of this manual. DBK42 16-Slot 5B Signal Conditioning Module Overview 1 Hardware Setup 2 DBK42 Connection 2 DBK42 Configuration 2 5B Module Connection 2 Power Considerations 2 Terminal Block Connections 3 DaqBoard/2000

More information

WITURA CORPORATION SDN BHD

WITURA CORPORATION SDN BHD WT 1010SA Stand Alone GSM Alarm System User Manual and Installation Instructions Version: 1.2 Updated: 4 JAN 2012 WITURA CORPORATION SDN BHD Stand Alone GSM Alarm System Instruction Manual 1 Introduction:

More information

GPS Vehicle Tracker (GPS+GSM+GPRS) User Manual (Version 1.2)

GPS Vehicle Tracker (GPS+GSM+GPRS) User Manual (Version 1.2) GPS Vehicle Tracker (GPS+GSM+GPRS) User Manual (Version 1.2) Please read this manual carefully before attempting installation and online activation. Pictures are for indication and illustration purposes

More information

Setting Up the Cisco IP Phone

Setting Up the Cisco IP Phone CHAPTER 3 This chapter includes this following topics, which help you install the Cisco IP Phone on an IP telephony network: Before You Begin, page 3-1 Installing the Cisco IP Phone, page 3-6 Adjusting

More information

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

GSM AD05 Slave GSM Auto Dialer- Instruction Manual GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

GSM Smart Switch USER GUIDE

GSM Smart Switch USER GUIDE GSM Smart Switch USER GUIDE GSM Smart Switch allows switching almost any appliance ON and OFF remotely via mobile network. It is designed to receive start/stop commands from specially coded messages or

More information

GPS Vehicle Tracker (GPS+GSM+GPRS) User Manual For GT02 (Version 1.2)

GPS Vehicle Tracker (GPS+GSM+GPRS) User Manual For GT02 (Version 1.2) GPS Vehicle Tracker (GPS+GSM+GPRS) User Manual For GT02 (Version 1.2) UVI Group Corporation 11C, HaiYue Building, HuiJing Garden, Nanshan Technology Park, Shenzhen, China Tel: +86-755-83315079 Mobile:

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

I NTERFACE CABLE ADAPTER MODULE

I NTERFACE CABLE ADAPTER MODULE I NTERFACE CABLE ADAPTER MODULE The Interface Cable Adapter Module (ICAM) has two basic uses. First, it enables you to run shielded cable between the industrial sensor interface module (SIM) and the weather

More information

200 Range Dialer Installation Manual. Version 1.0

200 Range Dialer Installation Manual. Version 1.0 200 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract

More information

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual 0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security

More information

Gateway) Manual. User's. Brand: Etross. Model: ET-8848 TEL:+86-755-26205464 FAX:+86-755-28167031

Gateway) Manual. User's. Brand: Etross. Model: ET-8848 TEL:+86-755-26205464 FAX:+86-755-28167031 301,3/F, Block B, Yuetong Comprehensive Bldg. Meilong Rd, Longhua, Bao an District Shenzhen China 518109 TEL:+86-755-26205464 FAX:+86-755-28167031 GSM FWT-8848 (Gateway Gateway) User's Manual Brand: Etross

More information

Model PBX 206 Programming & User Guide

Model PBX 206 Programming & User Guide Model PBX 206 Programming & User Guide 1 Contents Page For Quick Plug and Play install Guide see page 10 Programming & Set Up General Information 3 Incoming Ringing 3 Do you Have 1 or 2 exchange Lines?

More information

Schneider Automation Modbus Plus Network Installing Clustered Node Devices 31000939 00 Version 2.0

Schneider Automation Modbus Plus Network Installing Clustered Node Devices 31000939 00 Version 2.0 Schneider Automation Modbus Plus Network Installing Clustered Node Devices 3000939 00 Version.0 Modbus Plus devices must be installed as specified in a network layout plan, showing each device s mounting

More information

TO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS?

TO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS? TO-PASS -FAQ- Remote Monitoring What is TO-PASS used for? TO-PASS modules are used as/for: Permanent online connection Fault detectors Remote data polling Data storage Telecontrol module What are the special

More information

APD-T01 Telephone Auto-Dialer

APD-T01 Telephone Auto-Dialer APD-T01 Telephone Auto-Dialer installation & user guide APD-T01 Telephone Autodialer While the WeatherGoose monitor series provides IT administrators and facilities managers with a powerful combination

More information

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited (Rev. 1.0) China Aerospace Telecommunications Limited Contents 1. Introduction......3 2. Specifications...4 2.1 External Interface... 4 2.2 Status Indicator...... 5 2.3 Technical Parameters... 6 3. Device

More information

Easy Plug-in installation (Free to move from phone to phone)

Easy Plug-in installation (Free to move from phone to phone) User Manual for Autodialer v5.36 1. Features (1) Store up to 4 phone card accounts. Compatible with many prepaid and postpaid calling cards, dial around plans. (2) The autodialer will reroute user s calls

More information

Evaluation Board. i-modul and Socket. Manual

Evaluation Board. i-modul and Socket. Manual Evaluation Board i-modul and Socket Manual Copyright March 14 INSYS MICROELECTRONICS GmbH Any duplication of this manual is prohibited. All rights on this documentation and the devices are with INSYS

More information

CAD-05 Kit GSM Auto Dialer. Owner s Manual

CAD-05 Kit GSM Auto Dialer. Owner s Manual CAD-05 Kit GSM Auto Dialer Owner s Manual CAD-05 Kit Manual.indd 1 Warnings: This device complies with Part 15 of the FCC rules, Operation of this device is subject to the following conditions: 1. This

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

Table of Contents. Creating a VC1000 Network... 3

Table of Contents. Creating a VC1000 Network... 3 2 Table of Contents Creating a VC1000 Network... 3 Topology... 3 Unit ddressing... 4 Terminating Resistors... 5 Shielding... 5 Interconnecting the common... 6 ias Resistors... 6 VC1000 Hardware Configuration...

More information

AUTODIALLER / QUICKDIALLER - SA132

AUTODIALLER / QUICKDIALLER - SA132 AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Smart Energy Control... Temperature & Humidity SMS Alert Controller Energy Saving, Environment & Proper es Protec on 2 temperature sensors or 1 x temperature & 1 x humidity sensor Keep track of temperature

More information

6 U CompactPCI Backplane with 8 Slots

6 U CompactPCI Backplane with 8 Slots 6 U CompactPCI Backplane with 8 Slots State of the art design for a wide range of applications General Description This standard backplane is member of the ERNI backplane familiy for use in Compact PCI

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

InnoMedia ESBC 9580-4B. Quick Install Guide. www.innomedia.com 1

InnoMedia ESBC 9580-4B. Quick Install Guide. www.innomedia.com 1 InnoMedia ESBC 9580-4B Quick Install Guide www.innomedia.com 1 Table of Contents Introduction 2 Package Contents 2 CAUTION 2 Installation 3 Wall-Mounting Instructions 5 Troubleshooting 6 Appendix A. LED

More information

GSM Desktop phone DPH101. User manual v1.00

GSM Desktop phone DPH101. User manual v1.00 GSM Desktop phone DPH101 User manual v1.00 LEGAL NOTICE Copyright 2011 TELTONIKA Ltd. All rights reserved. Reproduction, transfer, distribution or storage of part or all of the contents in this document

More information

User guide. MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG

User guide. MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG User guide MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG Doorstation with telephone line interface for the connection to telephone systems Version with 1 bell button Page 1 Contents Description...3

More information

Alarm Cards. Reference Guide. Publication 999-001967 Revision A1

Alarm Cards. Reference Guide. Publication 999-001967 Revision A1 Alarm Cards Reference Guide Publication 999-001967 Revision A1 Release 3.9 October 1999 Running Head Model No. Trademarks: 5ESS is a registered trademark of Lucent Technologies DMS-100 and DMS-200 are

More information

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TRACETEK TraceTek TTDM Replacement Parts General Information These instructions detail the steps to

More information

How To Use A 1232 On A 1236 On A Computer Or A Cell Phone

How To Use A 1232 On A 1236 On A Computer Or A Cell Phone 12-36-1000 Autodialler and Relay Telephone Interface 1.0 INTRODUCTION 12-36-1000 I/O Telephone Interface with AutoDialer The 12-36-1000 is a autodialer and telephone interface that can be used autonomously

More information

GSM-DL2 GSM auto dialer

GSM-DL2 GSM auto dialer Introduction GSM-DL2 GSM auto dialer GSM-DL2 is a GSM auto dialer; designed for car alarm, boat alarm, home alarm and other applications. When it is triggered, it dials pre-programmed telephone numbers

More information

emta (VoIP over Cable Modem)

emta (VoIP over Cable Modem) emta (VoIP over Cable Modem) User Manual Version 1.0 Important Rules for Safe Operation Safe Use of Equipment Read all the instructions before operating this equipment with particular emphasis to safety

More information

Zetron Desktop Microphone Manual 025-9589F

Zetron Desktop Microphone Manual 025-9589F Zetron Desktop Microphone Manual 025-9589F Software License The Zetron software described in this manual is subject to the terms and conditions of Zetron's Software License Agreement, a copy of which is

More information

QUICK INSTALLATION GUIDE

QUICK INSTALLATION GUIDE QUICK INSTALLATION GUIDE (v. 1.1) WARNING: This is a class A product. In a domestic environment this product may cause radio interference

More information

FAQ s on Siemens Magmeters

FAQ s on Siemens Magmeters FAQ s on Siemens Magmeters 1. The cables for the coils and electrodes for the magmeters look the same. Does it matter which cable is used for coils and which one is used for the electrodes? Both cables

More information

USER MANUAL V5.0 ST100

USER MANUAL V5.0 ST100 GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

TFM GSMRoute BRI. Quick Installation Guide

TFM GSMRoute BRI. Quick Installation Guide TFM GSMRoute BRI Quick Installation Guide Connecting to ISDN Lines Basic Rate ISDN can be connected to the GSMRoute-BRI. Auto detects Point to Point or Point to Multipoint. Auto detects if ISDN circuit

More information

Setting Up the Cisco Unified IP Phone

Setting Up the Cisco Unified IP Phone CHAPTER 3 This chapter includes the following topics, which help you install the Cisco Unified IP Phone on an IP telephony network: Before You Begin, page 3-1 Understanding the Cisco Unified IP Phone 6901

More information

Falcon Protector Tracking System

Falcon Protector Tracking System Falcon Protector Tracking System Product Overview The Falcon Protector is a GPS and GSM tracking device which is specially developed and designed for vehicle tracking. With the latest SIFR III GPS module

More information

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0 SVC400P/SVC800P 4/8 Camera Live Tracking Vehicle DVR Installation Manual Version 1.0 1. MAIN FEATURES... 2 2. PRODUCT OVERVIEW... 2 3. DIMENSIONS... 4 4. PACKAGE CONTENTS... 5 5. MOUNTING AND ENVORNMENTAL

More information

E-PDD Duct Smoke Detector Installation Sheet

E-PDD Duct Smoke Detector Installation Sheet E-PDD Duct Smoke Installation Sheet Operation The duct smoke detector's primary purpose is to provide early warning of an impending fire and shut down the HVAC unit in order to prevent smoke from circulating

More information

Installation Manual ISDN Telephone Systems tiptel.com 410 tiptel.com 810 tiptel.com 411 tiptel.com 811 tiptel.compact 42 IP 8 tiptel.

Installation Manual ISDN Telephone Systems tiptel.com 410 tiptel.com 810 tiptel.com 411 tiptel.com 811 tiptel.compact 42 IP 8 tiptel. Installation Manual (UK) ISDN Telephone Systems tiptel.com 410 tiptel.com 810 tiptel.com 411 tiptel.com 811 tiptel.compact 42 IP 8 tiptel.compact 82 IP 8 tiptel Table of contents Table of contents Table

More information

CAT5 Video Display Quick Installation Guide

CAT5 Video Display Quick Installation Guide CAT5 Video Display Quick Installation Guide International HQ Jerusalem, Israel Tel: + 972 2 535 9666 minicom@minicom.com w w w. m i n i c o m. c o m North American HQ European HQ Linden, NJ, USA Dübendorf,

More information

1-Port R422/485 Serial PCIe Card

1-Port R422/485 Serial PCIe Card 1-Port R422/485 Serial PCIe Card Installation Guide 1. Introduction Thank you for purchasing this 1-Port RS422/485 Serial PCI Express (PCIe) Card. It is a universal add in card that connects to a PC or

More information

Sage 925VST Application Note Testing Through WiFi and VoIP Phones

Sage 925VST Application Note Testing Through WiFi and VoIP Phones SAGE INSTRUMENTS, 240 AIRPORT BLVD., FREEDOM, CA 95019-2614 Ph (831) 761-1000 Fax (831) 761-2452 www.sageinst.com Sage 925VST Application Note Testing Through WiFi and VoIP Phones Introduction This document

More information

Installation instructions for Series NRX INCOM communications adapter module

Installation instructions for Series NRX INCOM communications adapter module 4000 NRX RF DRAWOUT SUBTITLE IMAGE (12/15/2010) Effective July 2015 Supersedes October 2010 IL01301033EH04 Installation instructions for Series NRX INCOM communications adapter module Instructions apply

More information

How To Set Up A Phone On A Btv 206 (Bta) On A Cell Phone Or Landline) On An Iphone Or Ipad Or Ipa (Phone) On The Btva) On Sim Sims 2

How To Set Up A Phone On A Btv 206 (Bta) On A Cell Phone Or Landline) On An Iphone Or Ipad Or Ipa (Phone) On The Btva) On Sim Sims 2 Model PBX 206 User Guide 1 Contents Page General Information 3 Incoming Ringing 3 Do you Have 1 or 2 exchange Lines? 3 Auto Attendant (DISA) 3 To Record Out Going Message (OGM) 4 To Set System for DISA

More information

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128 Dallas Delta Corporation Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128 Email: sales@dallasdelta.com.au www.dallasdelta.com.au LP GUARD DOORSTATION MK II G UARD Doorstation

More information

RC2200DK Demonstration Kit User Manual

RC2200DK Demonstration Kit User Manual Demonstration Kit User Manual Table of contents TABLE OF CONTENTS... 1 QUICK INTRODUCTION... 2 INTRODUCTION... 3 DEMONSTRATION BOARD... 4 POWER SUPPLY SECTION... 5 RS-232 INTERFACE... 6 CONNECTORS... 7

More information

xpico Wi-Fi Embedded Device Server Evaluation Kit Quick Start Guide

xpico Wi-Fi Embedded Device Server Evaluation Kit Quick Start Guide xpico Wi-Fi Embedded Device Server Evaluation Kit Quick Start Guide Part Number 900-685 Revision A June 2013 Copyright and Trademark Contacts 2013 Lantronix, Inc.. All rights reserved. No part of the contents

More information

com.sat ISDN Plus 1 2009 com.sat GmbH Kommunikationssysteme Schwetzinger Str. 19 D-68519 Viernheim www.comsat.de Tel: +49-(0) 180-3-768837

com.sat ISDN Plus 1 2009 com.sat GmbH Kommunikationssysteme Schwetzinger Str. 19 D-68519 Viernheim www.comsat.de Tel: +49-(0) 180-3-768837 com.sat ISDN Plus GSM-Gateway-product Gateway line with wide range functionalities 1 2009 com.sat GmbH Kommunikationssysteme Schwetzinger Str. 19 D-68519 Viernheim www.comsat.de Tel: +49-(0) 180-3-768837

More information

M72. Quectel Cellular Engine. EVB User Guide M72_EVB_UGD_V1.0

M72. Quectel Cellular Engine. EVB User Guide M72_EVB_UGD_V1.0 M72 Quectel Cellular Engine EVB User Guide M72_EVB_UGD_V1.0 Document Title EVB User Guide Version 1.0 Date 2011-05-18 Status Document Control ID Release M72_EVB_UGD_V1.0 General Notes Quectel offers this

More information

Space Duel, Gravitar, Black Widow MultiVector INSTALL GUIDE

Space Duel, Gravitar, Black Widow MultiVector INSTALL GUIDE Space Duel, Gravitar, Black Widow MultiVector INSTALL GUIDE The Space Duel 3 in1 MultiVector kit includes the main PWB pictured above. IF YOU HAVE AND PROBLEMS OR SUGGESTIONS ON HOW TO IMPROVE THIS INSTALL

More information

How To Set Up An Inverter

How To Set Up An Inverter MAKING MODERN LIVING POSSIBLE SOLAR INVERTERS Installation Guide GSM Option Kit FLX series www.danfoss.com/solar Safety Safety Safety Message Types WARNING Safety information important for human safety.

More information

STATUS POWER MONITOR ALARM SOS DISARM

STATUS POWER MONITOR ALARM SOS DISARM STATUS POWER MONITOR ALARM SOS DISARM I. Features II. Preparation before use III. Host 1.LED status explanation 2. Host panel IV. System Settings 1. Coding of wireless sensors 2. Exit coding 3. Settings

More information

InnoMedia ESBC 9380-4B. Quick Install Guide. www.innomedia.com 1

InnoMedia ESBC 9380-4B. Quick Install Guide. www.innomedia.com 1 InnoMedia ESBC 9380-4B Quick Install Guide www.innomedia.com 1 Table of Contents Introduction 2 Package Contents 2 CAUTION 2 Installation 3 Wall-Mounting Instructions 5 Troubleshooting 6 Appendix A. LED

More information

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2 COMMERCIAL INSTALL GUIDE 2 Contents How to Use This Guide: The first section of this guide is designed to assist you with the installation of your DECK Monitoring hardware. The revenue grade meter and

More information

DO NOT RETURN THIS PRODUCT TO THE STORE! Please read the following important information For Siemens Customer Care, product operation information, or for problem resolution, call toll-free 1-888-777-0211

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

SafeLine MX2. Installation manual. Small, inexpensive and intelligent. Probably the world s smallest EN81-28 compatible lift telephone!

SafeLine MX2. Installation manual. Small, inexpensive and intelligent. Probably the world s smallest EN81-28 compatible lift telephone! SafeLine MX2 Installation manual Small, inexpensive and intelligent. Probably the world s smallest EN81-28 compatible lift telephone! 10.2012 SafeLine MX2 Installation manual Technical data Power: Emergency

More information

HTC Windows Phone 8X - Disassemble Guide

HTC Windows Phone 8X - Disassemble Guide HTC Windows Phone 8X - Disassemble Guide TTT-9007 Small Phillips Screwdriver TTT-9010 Plastic Opening Tools TTT-9013 Spudger Heat Gun / Blow Dryer This guide will show you how to disassemble the HTC Windows

More information

GSM Gate Opener GSM Remote Switch RTU5015 User Manual

GSM Gate Opener GSM Remote Switch RTU5015 User Manual GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener

More information

Interface between Eircom Network and Additional Telephone Equipment

Interface between Eircom Network and Additional Telephone Equipment Interface between Eircom Network and Additional Telephone Equipment External Terminating Unit The ETU (small cabinet, 230mm x 150mm x 150mm) is fitted by the customer on an exterior wall, at a point approx

More information