Hardwired/Wireless Electronic Security System

Size: px
Start display at page:

Download "Hardwired/Wireless Electronic Security System"

Transcription

1 Hardwired/Wireless Electronic Security System Features 16 Programmable User Codes 8 Radio Remote User Codes Entry and Exit Warning 6 Programmable Burglary Zones 2 Programmable Burglary Zones Zone Lockout Swinger Shutdown Sensor Watch Day Alarm Automatic Arming/Disarming Dual Reporting Answering Machine Bypass Telco Arming/Disarming Sequence AC Fail and System Fault Indications Event Memory Recall Walk Test Mode Upload/Download Programmable Monitored Speaker Output 5 Programmable Outputs EDMSAT - Satellite Siren Unique Fire Alarm Sound Dual Entry Timers In-Built Line Fail Monitor Open/Close Reports Selectable By User Code Delay Sirens Until Transmission is Complete Specifications Temperature Range: 0 to 45 Celsius Humidity: 10% to 95% Adapter: EDM TF008 Power Requirements:18-22 volts AC 22VA min Standby Current: 65mA Current Draw : 115mA (In Alarm Condition) Current Draw : 105mA (With No Alarm and Codepad Fitted) Weight: 2.5 Kg Back-up Battery: 6.5 Ah/12 volt D.C. Rechargeable Sealed Lead Acid Cabinet Dimensions: 306mm x 260mm x 76mm (metal) Supplier Code: N771 Austel Approval No.: A94/02B/0476 NZ Telepermit No.: PTC 211/98/084 RF3334 Wireless Keyfob RF3401 Wireless Reed Switch RF920 Wireless PIR Motion Detector Optional Enhancements RF3222 Receiver RF280TH Wireless Smoke Detector OFFICE 1 OFFICE 2 COMMON AREA OFFICE 3 OFFICE 4 Legend Codepad Reed Switch Movement Detector AVAILABLE FROM: Electronic Design & Manufacturing (A.C.N ) 25 Huntingwood Drive, Parramatta NSW 2510 Telephone: (61-2) Facsimile: (61-2)

2 USER FRIENDLY features include automatic arming and single button arming for both the AWAY Mode or STAY Mode. AWAY Mode allows you to arm both interior and exterior zones when you are leaving the premises. STAY Mode allows the system to be armed with the interior zones automatically isolated allowing movement within these areas, while at the same time protecting the perimeter zones. USER PROGRAMMABLE There are two STAY Mode operations that are available with the Solution 862 control panel. STAY Mode 1 and STAY Mode 2 operate in the same manner except that STAY Mode 1 can only be programmed by the installer, whereas STAY Mode 2 is programmable by any of the system's Master Code holders making it easy for them to change when needed. HAND HELD CONTROL A range of hand held radio remote transmitters and receivers may be added to the system to allow those people who have trouble remembering codes or find using personal operating code numbers confusing. The hand held remote control transmitter will provide the simplest of user interfaces between the control panel and the operator. CODEPADS A selection of remote codepads is available to suit the Solution 862 control panel including both LED indicator and LCD type. All codepads have backlit rubber push buttons to make operation extremely easy during day or night. The system provides 8 fully programmable zones by using split EOL resistors and also allows you to select the EOL resistor value you require so that the control panel can easily replace any existing system. You know what you want. You ve put a lot of thought and planning into the appearance of your home or office. When you install a security system, you want it to be unobtrusive, economical, effective and easy to use. Sensor location shouldn t be determined by wiring runs and conduit... You d rather an installer didn t take a number 8 auger to your oak crown molding... You want to be able to arm and disarm your system from anywhere, without having to remember a seven digit number, or pushing a complicated sequence of keys. Sophisticated A hardwired panel for a WIRELESS The Solution Ultima 862 security system provides sophisticated electronic surveillance for your home or business. Incorporating the very latest in microprocessor technology the Solution Ultima 862 combines useful features with superior reliability and performance. WORLD Simple and effective For exceptional ease of operation, flexibility and economy of installation, the hardwired panel can incorporate an optional wireless receiver to interact with a variety of wireless devices, such as RF PIR motion detectors, RF smoke detectors and RF door transmitters. At your command A small wireless keyfob that fits easily in pocket or purse is all you need to arm or disarm your system, send a panic signal or operate auxiliary devices. The Solution Ultima 862 puts an entire security system in the palm of your hand.

3 OPMET System The GWDI OPMET System provides timely and tailored meteorological information in support of flight operations. The system has been designed to be in full conformance with ICAO Annex 3. Features: Stand-alone and Integrated Configuration Data Acquisition and Storage Delivery of Weather Information Self-briefing Terminal Scheduled Preflight Bulletins Weather Watch Global Weather Dynamics, Inc Garden Road Monterey, CA Phone: (831) Fax: (831) Global Weather Dynamics, International 5801 Lee Highway Arlington, VA USA Phone: (703) Fax: (703)

4 Global Weather Dynamics, Inc. Stand-alone and Integrated Configuration The GWDI OPMET System can be configured as a stand-alone computer system, or it can execute on the same computer as the GWDI AFTN Message Switch or GWDI AIS System. If configured as a stand-alone system, the system consists of dual Compaq 64-bit AlphaServers in a primary/hot standby configuration. The operating system is UNIX. All information is stored on an industry standard Relational Database Management System (RDBMS). Data Acquisition and Storage The OPMET System will ingest data from any available source including the AFTN, MOTNE, ROBEX, CIDIN, or WMO GTS Networks. An interface to SADIS and ISCS ground stations is also supported. Data can be in either AFTN or WMO message formats and the facility exists to transform messages from one format to the other. All received data is validated and stored in a relational database. The facility exists for the operator review and correction of data that fails the basic validity checks. The data types handled include METARs, TAFs, SIGMETS, PIREPs, Area and Route forecasts. WAFS graphic data including upper air wind and temperature charts, SIG WX charts can also be received and stored on the database. Finally, binary upper air wind and temperature (GRIB and BUFR) data can be received and stored for later retrieval. Delivery of Weather Information The OPMET system will support flight operations by providing a complete meteorological briefing. This can be requested in one of three ways: 1) through the receipt of an AFTN message, 2) through a request from the GWDI AIS system, 3) through an interactive query from a user terminal, or 4) through a query by an Internet browser. The request for weather information is in the form of a query using the OPMET system s powerful query language. This language permits complex queries to be predefined and invoked by reference to the stored query. OPMET System OPMET System Timely, Tailored Meteorological Information The delivery of a query response is accomplished through the return of messages to the AFTN or CIDIN network; as a briefing sent to a remote fax machine; or as a response to the requesting Internet browser. Graphic products can be returned to fax and browser destinations. Self-Briefing Terminal If the OPMET System is used in conjunction with the GWDI Aeronautical Information Terminal (AIT), the AIT can be configured as a self-briefing terminal, providing an easy fill-in-the-blanks interface for the user. This ensures that an accurate query is entered and hides the pilot from the complexity of the query process. Scheduled Preflight Bulletins Preflight Briefings can be pre-scheduled and are constructed at a specific time on specific days prior to transmission to their intended recipient. Weather Watch The OPMET System also supports Weather Alert Messages (WAMs). Individual subscribers can define the weather conditions at specific locations that are significant to their flight operations. For example, IFR conditions at a particular airport, or a decreasing temperature-dew point spread. When a condition is met, the OPMET System will generate a message. Global Weather Dynamics, Inc Garden Road Monterey, CA Phone: (831) Fax: (831) Global Weather Dynamics, International 5801 Lee Highway Arlington, VA USA Phone: (703) Fax: (703) info@gwdi.com PIB#15

5

6 Do the Math - with Murray & Marv Question: Murray and Marvin plan to meet for a beer after work. They each have to install security devices in identical mini-malls which have six stores each. Murray will install DS940 easy mounting, small, accurate and unobtrusive PIR detectors. Marvin will install a competitor's product. After the job is finished, how long will Murray have to wait before he drinks Marvin's beer, pays the tab and goes home? Answer: Murray will wait as long as it takes him to drink his own beer, then he will drink Marvin's beer, pay the tab and go home. He knows that Marvin won't be finished today. Marv doesn t have the flexible mounting options of the DS940. Murray doesn t mind picking up Marv s tab His client is so impressed with the DS940's that he hired Murray to secure his next two projects. Practical application: Get an attractive, effective and easy to install security solution with the DS940 PIR. Only slightly larger than a deck of cards, it provides 40 ft. coverage and internal vertical and horizontal pointability. D E T E C T I O N S Y S T E M S 130 Perinton Parkway, Fairport, New York (888)

ICP-CC488. Installation Guide ICP-CC488 Control Panel

ICP-CC488. Installation Guide ICP-CC488 Control Panel ICP-CC488 EN Installation Guide ICP-CC488 Control Panel ICP-CC488 Installation Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems,

More information

Solution Ultima ICP-CC488 Home security you can rely on

Solution Ultima ICP-CC488 Home security you can rely on Solution Ultima ICP-CC488 Home security you can rely on Keeping your home and family safe doesn t need to be complicated. That s why we ve made the Ultima security system so easy to use all it takes is

More information

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide ICP-CC488 EN User s Guide ICP-CC488 Control Panel ICP-CC488 User's Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems, Inc. ( Bosch

More information

Solution Ultima ICP-CC488 Home security you can rely on

Solution Ultima ICP-CC488 Home security you can rely on Solution Ultima ICP-CC488 Home security you can rely on Keeping your home and family safe doesn t need to be complicated. That s why we ve made the Ultima security system so easy to use all it takes is

More information

Solution 880 Operators Manual ISSUE 1.10

Solution 880 Operators Manual ISSUE 1.10 Solution 880 Operators Manual ISSUE 1.10 Solution 880 Operators Manual Copyright 2001 by, SYDNEY, AUSTRALIA Document Part Number MA408O DOCUMENT ISSUE 1.10 Printed 25 May 2001 This documentation is provided

More information

VR8. User Guide Intruder Alarm System

VR8. User Guide Intruder Alarm System VR8 EN User Guide Intruder Alarm System VR8 User Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch ). All rights

More information

Solution 862 Operators Manual. Issue 1.00

Solution 862 Operators Manual. Issue 1.00 Solution 862 Operators Manual Issue 1.00 Solution 862 Operators Manual Copyright 1998 by Electronics Design and Manufacturing Pty Limited, SYDNEY, AUSTRALIA Document Part Number MA406O Document Issue

More information

!"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40

!#$%&'()**+),-+)).( /'0%1##1%&'(21'$1#( ISSUE 1.40 !"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40 MA8XXI 34&0(5167(410(877'(&'9#$:7:(;"

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

Solution-16 Operators Manual ISSUE 1.60

Solution-16 Operators Manual ISSUE 1.60 Solution-16 Operators Manual ISSUE 1.60 !"#$%&"'()*+ Operators Manual Copyright 2002 by, SYDNEY, AUSTRALIA Document Part Number MA880O DOCUMENT ISSUE 1.60 Printed 22 March 2002 This documentation is provided

More information

NESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL

NESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL NESS D16 16 Zone Control Panel and Dialler OWNER S MANUAL REVISION 2, JULY 2001 Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia

More information

ICP-CC404 ICP-CC404 EN. Control Panel. User s Guide

ICP-CC404 ICP-CC404 EN. Control Panel. User s Guide ICP-CC404 EN User s Guide ICP-CC404 Control Panel ICP-CC404 User's Guide Copyright Notice Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems, Inc.

More information

Solution-16 Operators Manual ISSUE 1.40

Solution-16 Operators Manual ISSUE 1.40 Solution-16 Operators Manual ISSUE 1.40 Solution-16 Operators Manual Copyright 1995-97 by, SYDNEY, AUSTRALIA Document Part Number MA880O Document Issue 1.40 Printed 29 July 1997 This documentation is

More information

ICP-CC488 ICP-CC488 EN. Control Panel. Quick Reference Guide

ICP-CC488 ICP-CC488 EN. Control Panel. Quick Reference Guide ICP-CC488 EN Quick Reference Guide ICP-CC488 Control Panel ICP-CC488 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security

More information

ICP-CP500. User's Guide ICP-CP500 Codepads

ICP-CP500. User's Guide ICP-CP500 Codepads ICP-CP500 EN User's Guide ICP-CP500 Codepads ICP-CP500 User's Guide 1.0 ICP-CP500 Series Codepads Overview EN 2 1.0 ICP-CP500 Series Codepads Overview The codepad is the communications interface between

More information

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand Elite 8D/Lite Version 8 Zone Controller 8 Arrowhead Alarm Products Ltd Operating Guide 1 Proudly Designed and Manufactured in New Zealand 2 CONTENTS Page No. INTRODUCTION 4 About your Alarm 4 OPERATING

More information

Solution-8 Control Panel

Solution-8 Control Panel Solution-8 Control Panel Issue 3c September 1994 Copyright 1994-1995 All rights reserv (MA 800 O) Important Note As there are many different types of consoles available for use with this control panel,

More information

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia s largest

More information

Solution 16 plus Security at your fingertips

Solution 16 plus Security at your fingertips Solution 16 plus Security at your fingertips Keeping your home and family safe doesn t need to be complicated. That s why we ve made the Bosch Solution 16 plus security system code pad just like an ATM

More information

Using your LED Plus keypad

Using your LED Plus keypad Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced

More information

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM Page 0 Table of Contents Introduction 1 System Basics.. 1 Burglary Protection.. 1 Fire Protection.. 1 Security Codes. 1 Zones and Partitions

More information

DESTINY 1/19/96 # 800-6006A

DESTINY 1/19/96 # 800-6006A DESTINY TABLE OF CONTENTS KEYPAD AND PHONE DIGIT QUICK REFERENCE NOTE: KEYPAD AND PHONE DIGIT QUICK REFERENCE POWER STATUS HOME AWAY MONITOR DESTINY INTRODUCTION CONTROL PANEL DETECTION DEVICES SWITCHES

More information

GE Concord 4 Quick User Guide

GE Concord 4 Quick User Guide GE Concord 4 Quick User Guide GE Concord 4 Quick User Guide Page 1 Before Calling Is the keypad beeping? Press *. This will silence the beeping and let you know where the trouble is. Is there a flashing

More information

Ademco Vista-20P/First Alert FA-168C Basic Commands

Ademco Vista-20P/First Alert FA-168C Basic Commands Zones 64 total Ademco Vista-20P/First Alert FA-168C Basic Commands Wireless Yes, Zones 09 to 48 + 16 Keyfob Zones (Zones 49 to 64) Batteries Downloadable Partitions 2 12 volt Rechargable inside main Panel,

More information

NESS D8 ALARM CONTROL PANEL AND DIALLER USER S MANUAL. NESS D8 CONTROL PANEL V4 USER MANUAL Revision 5 A$12.00 INC GST

NESS D8 ALARM CONTROL PANEL AND DIALLER USER S MANUAL. NESS D8 CONTROL PANEL V4 USER MANUAL Revision 5 A$12.00 INC GST NESS D8 ALARM CONTROL PANEL AND DIALLER USER S MANUAL NESS D8 CONTROL PANEL V4 USER MANUAL Revision 5 A$12.00 INC GST Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW

More information

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual SUPA8 Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS... 1 INSTALLATION OF THE SECURITY SYSTEM... 2 COMMISSIONING THE DIALLER PANEL... 5 ZONE INPUT CONNECTIONS... 7 PANEL

More information

Destiny 4100. Destiny 4100. Owners Manual

Destiny 4100. Destiny 4100. Owners Manual Destiny 4100 Destiny 4100 Owners Manual TABLE OF CONTENTS INTRODUCTION Control Panel...3 Detection Devices...3 Telephone Keypads...3 GLOSSARY... 4-5 LOCAL PHONE ACCESS Using Your Telephones As Keypads...6

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

Commander 2000 Control Panel

Commander 2000 Control Panel Commander 2000 Control Panel Interactive Technologies, Inc. File: Panels Overview Applications Features The Commander 2000 is an affordable wireless security system that is easy to install and easy to

More information

INSTALLATION MANUAL PC2525. Version 1.1

INSTALLATION MANUAL PC2525. Version 1.1 INSTALLATION MANUAL PC2525 Version 1.1 TABLE OF CONTENTS FEATURES 1 SPECIFICATIONS 1 INSTALLATION 2 Mounting the Panel... 2 Mounting the Keypad... 2 Auxiliary Power Connection... 2 Bell/Siren Connection...

More information

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE... TABLE OF CONTENTS...Glossary of terms...2...code Pad Diagram...3 Understanding the Code Pad lights...4 Code Pad tones...5 Fully arming the system On MODE...6 Fully arming the system - Quick Arm MODE...6

More information

500r+ Installation and User Guide

500r+ Installation and User Guide 500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and

More information

Six-defense zone Display Alarm System. User Manual

Six-defense zone Display Alarm System. User Manual Six-defense zone Display Alarm System User Manual Feature 1. Anti-interfere function. When someone interferes it with same frequency, the control unit will activate siren to alarm. 2. Support anti-decode

More information

S I E R R A PRODUCT INFORMATION GUIDE FOR HOME SECURITY. SIERRA Page 1

S I E R R A PRODUCT INFORMATION GUIDE FOR HOME SECURITY. SIERRA Page 1 S I E R R A PRODUCT INFORMATION GUIDE FOR HOME SECURITY SIERRA Page 1 C O N T E N T S USING YOUR SIERRA SYSTEM: Turning On/Off Home Arming Instant Home Arming Quick Exit Mode Chime Mode SPECIAL FUNCTIONS:

More information

User s Information Guide R1A

User s Information Guide R1A HSC505-R Home Security Controller - User Manual Release R1a Pi HSC505 and Pi HSC505R Home Security Controller User s Information Guide R1A Page 1 QD Dynamics (Pty) Ltd reserves the right to make changes

More information

SPECIAL CONTROL BUTTON FUNCTIONS

SPECIAL CONTROL BUTTON FUNCTIONS Operating Guide 1 2 3 CONTENTS Page No. OPERATING YOUR ALARM 5 General Information 5 Arming the Alarm 5 Disarming the Alarm 6 Arming in Stay Mode 7 Disarming Stay Mode 8 Bypassing Zones 8 Manual Panic,

More information

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One

More information

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT

More information

Simon XTi Installation Guide

Simon XTi Installation Guide Simon XTi Installation Guide Content Contact information... 1 Description... 1 Installation... 1 Connecting hardwired devices... 2 Wiring phone lines... 3 Wiring the power transformer... 4 Resetting memory

More information

IDS X-Series User Manual 700-398-01D Issued July 2012

IDS X-Series User Manual 700-398-01D Issued July 2012 1 2 Contents 1. Introduction to the IDS X-Series Panels... 7 2. Before Operating Your Alarm System... 7 3. Understanding the Keypad LEDs... 8 3.1 Viewing Data on an LED Keypad... 12 3.1.1 LED Status Indicators...

More information

FA701 Series. User s Guide. K6249-2V2 5/09 Rev. A

FA701 Series. User s Guide. K6249-2V2 5/09 Rev. A FA701 Series TouchCenter Keypads User s Guide K6249-2V2 5/09 Rev. A Table of Contents ABOUT THE TOUCHCENTER... 5 Introduction... 5 2 The TouchCenter Interface... 5 Navigating through the TouchCenter...

More information

GSM INTRUSION ALARM SYSTEM INSTRUCTION MANUAL. GSM - PSTN - SMS - TOUCH GSM Wireless Security Alarm System

GSM INTRUSION ALARM SYSTEM INSTRUCTION MANUAL. GSM - PSTN - SMS - TOUCH GSM Wireless Security Alarm System GSM INTRUSION ALARM SYSTEM INSTRUCTION MANUAL GSM - PSTN - SMS - TOUCH GSM Wireless Security Alarm System SECURE YOUR HOME AND BUSINESS Printed in Shenzhen RE: G60-GSM-August-2013 Key Features Smart touch

More information

Welcome to a whole new level of interactive home security

Welcome to a whole new level of interactive home security Welcome to a whole new level of interactive home security User Manual TouchScreen Key Fob Keychain Remote Web Access Mobile Access ReadyHome User Manual Introducing a whole new level of security for the

More information

First Alert FA140C/142C Installer Notes M. Leuck

First Alert FA140C/142C Installer Notes M. Leuck First Alert FA140C/142C Installer Notes M. Leuck 1. Programming can only be done by 6139 Alpha keypads, standard 6128 keypad cannot be used to program zones 2. Program new Master Code in section *20 (old

More information

securıty HOME home protection 101

securıty HOME home protection 101 securıty HOME home protection 101 Do I really need a security system? Yes, you do! There is always the sonal electronic sentry, able to see and risk of fire, theft, or home intrusion. hear trouble. It

More information

User Guide for the DS7060 Control/Communicator

User Guide for the DS7060 Control/Communicator DS7060 User Guide Copyright 1996-97 Detection Systems, Inc. User Guide for the DS7060 Control/Communicator Copyright 1996-97 Detection Systems, Inc. Detection Systems, Inc., 130 Perinton Parkway, Fairport,

More information

D24 USER S MANUAL ALARM CONTROL PANEL AND DIALLER. Ness D24 control panel User s manual A$15.00 INC GST. Revision 2

D24 USER S MANUAL ALARM CONTROL PANEL AND DIALLER. Ness D24 control panel User s manual A$15.00 INC GST. Revision 2 D24 ALARM CONTROL PANEL AND DIALLER USER S MANUAL A$15.00 INC GST Ness D24 control panel User s manual Revision 2 Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head

More information

S100. GSM House Alarm System. Http://www.GSMalarmsystem.com

S100. GSM House Alarm System. Http://www.GSMalarmsystem.com S100 GSM House Alarm System Http://www.GSMalarmsystem.com 1. Brief introduction The GSM Alarm System is a new security protection solution special for home, house and office and other applications. It

More information

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version) NetworX Series NX- 4/8 Code Pad User Manual (Australian Version) Table Of Contents Code Pad Diagram... Inside Front Glossary of Terms...2 Understanding the Code Pad lights...3 Code Pad Tones...4 Fully

More information

How To Use An F145C-1 With A Sim Sims 2 (Aq) And A Sims 1 (Aux) (Aipa) (For Aq) (F145C) (Ios) (Power

How To Use An F145C-1 With A Sim Sims 2 (Aq) And A Sims 1 (Aux) (Aipa) (For Aq) (F145C) (Ios) (Power First Alert FA145 Installer Notes M. Leuck 1. Programming can only be done by 6139 Alpha keypads, standard 6128 keypad cannot be used to program zones 2. Program new Master Code in section *20 (old version)

More information

Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.

Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer. Innovative GSM & WIFI dual network operating platform. On WIFI network, the alarm system will work without any fee. If no WIFI, it will work on GSM automatically. With state-of-the-art WIFI network technology,

More information

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL PINKERTON Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS...1 INSTALLATION OF THE SECURITY SYSTEM...2 COMMISSIONING

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-8 Control/Communicator Installation Manual Page General Description... 2 Ordering Information... 2 Option Definitions... 2 Programming the LED Code Pads... 4 Programming the NX-8... 8 Types

More information

Business/Home GSM Alarm System. Installation and User Manual

Business/Home GSM Alarm System. Installation and User Manual Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene

More information

DESTINY OWNER S MANUAL

DESTINY OWNER S MANUAL DESTINY OWNER S MANUAL DESTINY You have made a wise decision to protect your family and property with the DESTINY Security System. The DESTINY has been designed to provide you with a maximum level of security

More information

Security System. User's Guide. Keypad

Security System. User's Guide. Keypad Security System EN User's Guide Keypad Security System User's Guide This system includes a telephone line seizure feature. The system can be programmed to communicate with a central monitoring station

More information

A VOLUTION. S series. Avolution S Series Security System. ASSA ABLOY, the global leader in door opening solutions

A VOLUTION. S series. Avolution S Series Security System. ASSA ABLOY, the global leader in door opening solutions A VOLUTION TM S series Avolution S Series Security System ASSA ABLOY, the global leader in door opening solutions We know securing and safeguarding your home, family and your business is important to you

More information

TABLE OF CONTENTS FEATURES

TABLE OF CONTENTS FEATURES TABLE OF CONTENTS FEATURES 2 Keypad Programmable... 2 EEPROM Memory... 2 Static/Lightning Protection... 2 Supervision... 2 Operation... 2 SPECIFICATIONS 2 PC1550 Control Panel... 2 PC1500RK Keypad... 2

More information

HILLS Series LED Code Pad User Manual

HILLS Series LED Code Pad User Manual HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2

More information

Operating Guide. Alert 8D Version 8 Zone Controller Arrowhead Alarm Products Ltd

Operating Guide. Alert 8D Version 8 Zone Controller Arrowhead Alarm Products Ltd 8 Alert 8D Version 8 Zone Controller Arrowhead Alarm Products Ltd Operating Guide 20 1 Proudly Designed and Manufactured in New Zealand Installer Notes: Please contact your alarm installer if you require

More information

Contact ID as of 2/2/2015

Contact ID as of 2/2/2015 Contact ID as of 2/2/2015 100 Medical Zone A non-specific medical exists 101 Personal Emergency Zone Emergency Assistance request 102 Fail to report in Zone A user has failed to activate a monitoring device

More information

LW-2000-3A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets

LW-2000-3A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets LW-2000-3A Wireless Auto Dial Alarm System Sentry Plus User Manual By Global Gadgets Main Features Simple to use keypad for operation and control. The system can store up to 9 telephone numbers: positions

More information

tattletale User Guide Consumer unit version 2.48 1 P a g e

tattletale User Guide Consumer unit version 2.48 1 P a g e tattletale User Guide Consumer unit version 2.48 1 P a g e Contents Basic 1... 4 Base Unit Features... 4 Initial Setup... 4 Arming... 5 Disarming... 5 Quiet Button... 5 Settings... 5 Settings 2... 6 Quick

More information

Home Alarm System. Product Description

Home Alarm System. Product Description Home Alarm System The key elements of Zicom's Home Alarm System are the Main Panel, which is the brain of the system and the ialert Station (CMS). The other major components of Home Alarm Systems are as

More information

Users Guide to Keypad Functions

Users Guide to Keypad Functions Users Guide to Keypad Functions MANUAL NO. 700-175-01J ISSUED JAN 2002 VERSION 1.41 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Panic Fire Medical Away Arm Stay Arm Stay Arm &

More information

NetworX NX-6V2. LED Keypad User Manual

NetworX NX-6V2. LED Keypad User Manual NetworX NX-6V2 LED Keypad User Manual POWER Light is on when AC power is present; flashes to indicate a low battery condition. ARMED Light is on when armed; off when disarmed; flashes to indicate a previous

More information

CS848E Receiver for 868GEN2 Devices Installation Sheet

CS848E Receiver for 868GEN2 Devices Installation Sheet CS848E Receiver for 868GEN2 Devices Installation Sheet EN 1 2 1 3 4 2 3 EN: Installation Sheet Description The CS848E Receiver adds wireless capabilities to the CS line of control panels. The CS848E allows

More information

HomeSafe Security Panel User s Guide 5400 Series

HomeSafe Security Panel User s Guide 5400 Series HomeSafe Security Panel User s Guide 5400 Series CONTENTS Features... 4 Introduction... 5 Keypad... 6 Keypad Indicators... 7 OPERATION by KEYPAD... 8 Arming... 9 Disarming... 10 Resetting Alarms... 10

More information

Ness D8x / D16x alarm control panel. User's MANUAL. A$15.00 Revision 5.6

Ness D8x / D16x alarm control panel. User's MANUAL. A$15.00 Revision 5.6 Ness D8x / D16x alarm control panel User's MANUAL A$15.00 Revision 5.6 www.ness.com.au Australia s largest designer and manufacturer of high quality security products Head Office: Ness Security Products

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

USER S MANUAL. Ness R8 Radio Control Panel User s Manual A$15.00 INC GST. Revision 2

USER S MANUAL. Ness R8 Radio Control Panel User s Manual A$15.00 INC GST. Revision 2 USER S MANUAL A$15.00 INC GST Ness R8 Radio Control Panel User s Manual Revision 2 WWW.NESS.COM.AU Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only Australia s largest designer and

More information

GSM home alarm system s manual

GSM home alarm system s manual GSM home alarm system s manual I. Main features: 1, Eight wireless LED zone, and four wired zone 2, Two-way to communication 3, The system supports the GSM cell phones, no need the fixed telephone line.

More information

HILLS Series LED Code Pad User Manual

HILLS Series LED Code Pad User Manual HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2

More information

ACTIVE 5 ENGINEERING MANUAL

ACTIVE 5 ENGINEERING MANUAL ACTIVE 5 ENGINEERING MANUAL C & K Systems Ltd C031-066 Issue 3 THE ACTIVE 5 INSTALLATION MANUAL. Date: Feb 1997 INTRODUCTION. The Active 5 is a microprocessor controlled intruder alarm panel. It features

More information

DC-8706K Auto Dial Alarm System

DC-8706K Auto Dial Alarm System DC-8706K Auto Dial Alarm System User Guide Basic Contents: 1x the host unit; 1x wireless door (window) magnet; 1x wireless infrared detector; 2x remote control; 1x siren; 1x phone core; 1x AC to DC power

More information

Wireless Alarm system s manual

Wireless Alarm system s manual MOUNTVIEW TECH AUSTRALIA PTY LTD Wireless Alarm system s manual ADS A180 Series ADS Security 1/11/2011 1. Before You Begin For your safety and the safety of others, and to ensure that you get the most

More information

Ness D8x / D16x alarm control panel

Ness D8x / D16x alarm control panel Ness D8x / D16x alarm control panel A$15.00 User's MANUAL Revision 5.2 www.ness.com.au Australia s largest designer and manufacturer of high quality security products Head Office: Ness Security Products

More information

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ-100 08E55-SHJ-100. 2004 American Honda Motor Co., Inc. - All Rights Reserved.

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ-100 08E55-SHJ-100. 2004 American Honda Motor Co., Inc. - All Rights Reserved. Kit No. 08E5-SHJ-00 08E55-SHJ-00 Security System Owner s Manual ODYSSEY 004 American Honda Motor Co., Inc. - All Rights Reserved. Contents Introduction... 3 Emergency Disarming During the Panic Alarm Activation...

More information

ARCHITECT AND ENGINEER SPECIFICATION SECTION 13850 DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE. DSC MAXSYS PC4020 V3.

ARCHITECT AND ENGINEER SPECIFICATION SECTION 13850 DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE. DSC MAXSYS PC4020 V3. ARCHITECT AND ENGINEER SPECIFICATION SECTION 13850 DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE DSC MAXSYS PC4020 V3.5 Rev0x2 Digital Security Controls 3301 Langstaff Rd., Concord, ON Canada L4K

More information

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18 INHEP DIGITAL IDS S E C U R I T Y Users Guide to Keypad Functions MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm Stay

More information

www.ealarm.com.my P/N 5-051-371-00 Rev D

www.ealarm.com.my P/N 5-051-371-00 Rev D System 236 System 236i P/N 5-051-371-00 Rev D Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced alarm systems on the market today, designed to provide

More information

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete

More information

TouchScreen User Guide

TouchScreen User Guide TouchScreen User Guide Technicolor TCA203 Android Release 5.1 Hawaii SU1 December 19, 2012 TouchScreen User Guide 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013 icontrol Networks, Inc., the icontrol logo,

More information

616, 626, 636 & 646 Keypads

616, 626, 636 & 646 Keypads 616, 626, 636 & 646 Keypads User s Manual TABLE OF CONTENTS 1.0 BASIC OPERATION...2 2.0 ACCESS CODES...4 3.0 ARMING & DISARMING...6 4.0 PANIC ZONES...13 5.0 KEY ACCESS PROGRAMMING.14 6.0 ADDITIONAL FEATURES...15

More information

PowerCode Wireless. Fully supervised wireless system. Features

PowerCode Wireless. Fully supervised wireless system. Features PowerCode Wireless WIRELESS Fully supervised wireless system Features technology Fully supervised Attractive, elegant design Reporting of tamper and RF signal jamming Transmitter inactivity and low battery

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

National Security Systems Inc (800)457-1999. Security System User's Guide

National Security Systems Inc (800)457-1999. Security System User's Guide National Security Systems Inc (800)457-1999 Security System User's Guide Security System Glossary As security system technology has evolved, a special jargon has developed. Some terms widely used within

More information

SECURITY SYSTEM NOTES. Security System Configuration

SECURITY SYSTEM NOTES. Security System Configuration Installing / Service Company: For Service Call: SECURITY SYSTEM NOTES Security System Configuration Master Code: Auxiliary Code(s) 2 3 4 5 6 "Quick Arm" Digit: Exit Delay Time Auxiliary Exit Delay Time

More information

Contact ID Event Definition Codes

Contact ID Event Definition Codes Contact ID Event Definition Codes EVENT ALARMS Medical Alarms -100 100 Medical Zone 101 Personal Emergency Zone 102 Fail to report in Zone Fire Alarms -110 110 Fire Zone 111 Smoke Zone 112 Combustion Zone

More information

SECURITY SYSTEM NOTES SPECIAL CODES AUXILIARY ARM / DISARM CODES ENTRY / EXIT DELAY TIMES ZONE DESCRIPTIONS

SECURITY SYSTEM NOTES SPECIAL CODES AUXILIARY ARM / DISARM CODES ENTRY / EXIT DELAY TIMES ZONE DESCRIPTIONS SECURITY SYSTEM NOTES Installing/Service Company For Service Call SPECIAL CODES Master Code Duress Code "Quick Arm" Digit "Chime" Digit "Entry-Guard" Digit AUXILIARY ARM / DISARM CODES 02 12 22 03 13 23

More information

GSM ALARM SYSTEM USER MANUAL

GSM ALARM SYSTEM USER MANUAL GSM ALARM SYSTEM USER MANUAL 1. Instruction The alarm system is based on GSM network. With a GSM SIM card, it can be used wherever you want and no need to connect any wire, which is convenient and easy

More information

GSM Home Alarm System User Manual. http://www.usmartbuy.com

GSM Home Alarm System User Manual. http://www.usmartbuy.com GSM Home Alarm System User Manual http://www.usmartbuy.com 1 1. Factory default Normally, all sensors in the big box have been coded (learnt) to the control host Operation Password: 0000 Long-Distance

More information

SIMPLIFIED HOME SECURITY AND CONTROL

SIMPLIFIED HOME SECURITY AND CONTROL SIMPLIFIED HOME SECURITY AND CONTROL HOME CONTROLLER USER GUIDE HOME CONTROLLER Medicom indroduces a whole new level of security for the things that matter most in your life. Whether you re home or away,

More information

SECURIT 800L+ CONTROL PANEL

SECURIT 800L+ CONTROL PANEL USER MANUAL SECURIT 800L+ CONTROL PANEL COMPANY PROFILE IntelliSense have been successfully making security products for over 20 years and lead the security industry throughout the world with many innovative

More information

Cerber C612 12-Zone and 2-Partition Burglary Control Panel For your home and office

Cerber C612 12-Zone and 2-Partition Burglary Control Panel For your home and office Cerber C612 12-Zone and 2-Partition Burglary Control Panel For your home and office Doc 10905/ 09.2005/ version 2.0 User s Guide 1. INTRODUCTION...4 General Features...4 User Codes...4 Installer Codes...5

More information

securıty HOME home protection 101

securıty HOME home protection 101 securıty HOME home protection 101 Do I really need a security system? Yes, you do! There is always the risk of fire, theft, or home intrusion. Whether at home during the day, asleep at night, or away,

More information

SECURITY SYSTEM NOTES

SECURITY SYSTEM NOTES SECURITY SYSTEM NOTES Installing/Service Company For Service Call Central Station Duress Code FUNCTION CODES Function Code Controls Function This system is is not partitioned. EMERGENCY ACTIVATION KEYS

More information

Home Security Alarm System

Home Security Alarm System Home Security Alarm System User Manual (ALM-S02) Read manual carefully before use. PiSector Inc., USA www.pisector.com Thank you for purchasing this home security alarm system. For your safety and better

More information

Lynx Plus Series Security System

Lynx Plus Series Security System Lynx Plus Series Security System User Guide ARMED READY ESCAPE ADD OFF AWAY RECORD LIGHTS ON 1 2 3 VOLUME TEST PLAY 4 5 6 BYPASS 7 8 9 STAY DELETE AUX SELECT LIGHTS OFF 0 CODE CHIME STATUS NO DELAY FUNCTION

More information

Program Entry Guide. Control Panels

Program Entry Guide. Control Panels EN Program Entry Guide Control Panels D6412/D4412 Program Entry Guide EN 2 Documentation Conventions Type Styles Used in this Manual To help identify important items in the text, the following type styles

More information