BACnet Protocol Implementation Conformance Statement

Similar documents
BACnet protocol implementation conformance statement. Corrigo

SAUTER BACnet PICS EY-modulo 5 moduweb500 BACnet Protocol Implementation Conformance Statement

Dokumentationen für BACnet-Geräte - PICS

BACnet Protocol Implementation Conformance Statement

COMMUNICATION PROTOCOL pag. 1/7. BACnet Protocol Implementation Conformance Statement

BACnet Controller Integration with NAE/NCE Technical Bulletin

ControlMaestro and. BACnet integrated solution

Planning BACnet networks

BACnet Protocol Implementation Conformance Statement. Gebäudeautomationssystem Creative Automation Line

SHEET. BASautomation. BAS Router BACnet Multi-Network Router. BAS Router

Application Note #563 Revision A November 2015 Lutron / Automated Logic BACnet Integration

5178 EOI Direct Digital Controls Systems Strategic Plan Schedule A. Technical Submission. City of Richmond

Tracer Summit Web Server

Integrating fire alarm systems with building. Fire Alarm Systems with Building Automation and Control Systems INTEGRATING INTRODUCTION

SAUTER novapro Open: B-AWS. BACnet Advanced Workstation

Personna PC web-based software. Q-AdminTM client. Lighting management hub (floor 2) Lighting management hub (floor 1)

GUIDE. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

A TECHNICAL SUPPLEMENT TO CONTROL NETWORK ESSENTIALS. BACnet Discovery Tool Better than Ever but Still Free!

BACnet Network Security

ROAMview to BACnet IP Software Module

FieldServer Webinar Series

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Raising BACnet to the Next Level

BACnet Automation Interface Module (Network Version)

Personna PC web-based software. Q-AdminTM client. Lighting management hub (floor 1)

BACnet. bcx1 Controller/ Router Series

Tracer Summit. Critical Control System BAS-PRC017-EN. May 2004

Desigo V6.0 BACnet Router PXG3.M and PXG3.L Engineering and configuration Engineering

Daikin Magnitude TM Chiller Unit Controller BACnet Communication Module (MS/TP, IP, Ethernet)

Chapter 1 Configuring Internet Connectivity

A Systems Approach to HVAC Contractor Security

Smart Integration of Wireless Temperature Monitoring System with Building Automation System

ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance

7.6.4 Communication via BACnet MS/TP. Logical error. Maximum processing time, p2024[0] Process data monitoring time (setpoint timeout), p2040

DOMOTICA ED EDIFICI INTELLIGENTI UNIVERSITA DI URBINO

BUILDING AUTOMATION & CONTROLS, BUILDING AUTOMATION & CONTROLS, WHAT S NEW & WHAT WILL THE FUTURE BRING? WHAT S NEW & WHAT WILL THE FUTURE BRING?

L2F Case Study Overview

Honeywell. Installation and User Manual. BacNet protocol. for Variable Frequency Drives

Embedded Web Services: Making Sense out of Diverse Sensors

Portable BACnet /IP to MS/TP Router

BACnet: Answers to. Frequently Asked Questions. This article answers some of the most frequently ACHIEVING INTEROPERABILITY

System Architecture. Dr. Sam C M Hui. MECH3023: Building Energy Management & Control Systems

Local Area Network. OSI Seven Layer Model. Whole Building Network

By David G. Holmberg, Ph.D., Member ASHRAE

Bacnet for Field Technicians

Chapter 5. Data Communication And Internet Technology

Using Cisco UC320W with Windows Small Business Server

Prestige 310. Cable/xDSL Modem Sharing Router. User's Guide Supplement

FX07 Field Controller

MS/TP Communications Bus Technical Bulletin Code No. LIT Software Release 7.0 Issued July 2, 2015

Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials.

Emerson s Smart Wireless and WIB Requirements

BACnet Application Guide for Consulting Engineers

DATA SECURITY 1/12. Copyright Nokia Corporation All rights reserved. Ver. 1.0

How To Configure A Vyatta As A Ds Internet Connection Router/Gateway With A Web Server On A Dspv.Net (Dspv) On A Network With A D

Multi-Master DF1 Protocol User Guide

Chapter 1 Configuring Basic Connectivity

Access Control BUSINESS REQUIREMENTS FOR ACCESS CONTROL

Process Control and Automation using Modbus Protocol

Legacy Security

NETWORKING AND INTEGRATION

Configuring an APOGEE System on an IT Infrastructure White Paper

User Guide. Babel Buster 2. Model BB BACnet Gateway and Router

UNIVERSIDADE DA BEIRA INTERIOR Faculdade de Engenharia Departamento de Informática

Hanlong Technology Co., Ltd

Cloud Infrastructure Planning. Chapter Six

Supporting ANY PRODUCT employing

Quick Start Guide. RV 120W Wireless-N VPN Firewall. Cisco Small Business

A Simulation Analysis of BACnet Local. Area Networks

securityprobe 5E Standard

Communication and connectivity the ideal solution for integrated system management and data integrity

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Niagara IT Manager s Guide

Corp L6 04/09 Supersedes 06/08

Vocia MS-1 Network Considerations for VoIP. Vocia MS-1 and Network Port Configuration. VoIP Network Switch. Control Network Switch

Chapter 2 - The TCP/IP and OSI Networking Models

Can PowerConnect Switches Be Used in IP Multicast Networks?

SIP Trunking with Microsoft Office Communication Server 2007 R2

Service Managed Gateway TM. How to Configure a T1/E1 Connection

Seven Things Critical Facilities Managers Need to Know About Wirefree Monitoring

Failsafe WAN, VoIP, IVRS & LAN connectivity

Sentry Bulldog Shutdown Management Software (For UNIX Series)

How To Set Up A Net Integration Firewall

Question Name C 1.1 Do all users and administrators have a unique ID and password? Yes

Best practices on cellular M2M deployment. Paul Bunnell November 2014

Operation Manual Voice Overview (Voice Volume) Table of Contents

Public Review Draft. ASHRAE Standard

Evaluation guide. Vyatta Quick Evaluation Guide

OSBRiDGE 5XLi. Configuration Manual. Firmware 3.10R

CISCO SPA3102 PHONE ADAPTER WITH ROUTER

Chapter 6 Configuring the SSL VPN Tunnel Client and Port Forwarding

Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function

Original Design Manufacturing Service. Worldwide Locations. Design to Worldwide Standards. Worldwide Electronics Manufacturing.

Apple Airport Extreme Base Station V4.0.8 Firmware: Version 5.4

Configuration Notes 283

Abstract. MEP; Reviewed: GAK 10/17/2005. Solution & Interoperability Test Lab Application Notes 2005 Avaya Inc. All Rights Reserved.

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

Enabling NAT and Routing in DGW v2.0 June 6, 2012

The Best Technology for the Application. Educating the Specifier on Medical Air & Medical Vacuum Systems

User s Manual Network Management Card

Transcription:

BACnet Protocol Implementation Conformance Statement Date: 16/09/2015 Vendor Name: RPS S.p.A. Product Name: NetMan 204 Product Model Number: Application Software Version: 1.05 Firmware Revision: 1.05 BACnet Protocol Revision: 1.01 Product Description: BACnet Standardized Device Profile (Annex L): BACnet Operator Workstation (B-OWS) BACnet Advanced Operator Workstation (B-AWS) BACnet Operator Display (B-OD) BACnet Building Controller (B-BC) BACnet Advanced Application Controller (B-AAC) BACnet Application Specific Controller (B-ASC) BACnet Smart Sensor (B-SS) BACnet Smart Actuator (B-SA)

List all BACnet Interoperability Building Blocks Supported (Annex K): _ Segmentation Capability: Able to transmit segmented messages Window Size Able to receive segmented messages Window Size Standard Object Types Supported: An object type is supported if it may be present in the device. For each standard Object Type supported provide the following data: 1) Whether objects of this type are dynamically creatable using the CreateObject service 2) Whether objects of this type are dynamically deletable using the DeleteObject service 3) List of the optional properties supported 4) List of all properties that are writable where not otherwise required by this standard 5) List of all properties that are conditionally writable where not otherwise required by this standard 6) List of proprietary properties and for each its property identifier, datatype, and meaning 7) List of any property range restrictions Data Link Layer Options: BACnet IP, (Annex J)

BACnet IP, (Annex J), Foreign Device ISO 8802-3, Ethernet (Clause 7) ATA 878.1, 2.5 Mb. ARCNET (Clause 8) ATA 878.1, EIA-485 ARCNET (Clause 8), baud rate(s) MS/TP master (Clause 9), baud rate(s): MS/TP slave (Clause 9), baud rate(s): Point-To-Point, EIA 232 (Clause 10), baud rate(s): Point-To-Point, modem, (Clause 10), baud rate(s): LonTalk, (Clause 11), medium: BACnet/ZigBee (ANNEX O) Other: Device Address Binding: Is static device binding supported? (This is currently necessary for two-way communication with MS/TP slaves and certain other devices.) Yes No Networking Options: Router, Clause 6 - List all routing configurations, e.g., ARCNET-Ethernet, Ethernet-MS/TP, etc. Annex H, BACnet Tunneling Router over IP BACnet/IP Broadcast Management Device (BBMD) Does the BBMD support registrations by Foreign Devices? Yes No Does the BBMD support network address translation? Yes No

Network Security Options: Non-secure Device - is capable of operating without BACnet Network Security Secure Device - is capable of using BACnet Network Security (NS-SD BIBB) Multiple Application-Specific Keys: Supports encryption (NS-ED BIBB) Key Server (NS-KS BIBB) Character Sets Supported: Indicating support for multiple character sets does not imply that they can all be supported simultaneously. ISO 10646 (UTF-8) IBM /Microsoft DBCS ISO 8859-1 ISO 10646 (UCS-2) ISO 10646 (UCS-4) JIS X 0208 If this product is a communication gateway, describe the types of non-bacnet equipment/networks(s) that the gateway supports:

BACNET Object Description Unit Analog Input 0 Input voltage line 1 V Analog Input 1 Input voltage line 2 V Analog Input 2 Input voltage line 3 V Analog Input 3 Input current line 1 A Analog Input 4 Input current line 2 A Analog Input 5 Input current line 3 A Analog Input 6 Input frequency Hz Analog Input 7 Bypass voltage line 1 V Analog Input 8 Bypass voltage line 2 V Analog Input 9 Bypass voltage line 3 V Analog Input 10 Bypass frequency Hz Analog Input 11 Output voltage line 1 V Analog Input 12 Output voltage line 2 V Analog Input 13 Output voltage line 3 V Analog Input 14 Output current line 1 A Analog Input 15 Output current line 2 A Analog Input 16 Output current line 3 A Analog Input 17 Output peak current line 1 A Analog Input 18 Output peak current line 2 A Analog Input 19 Output peak current line 3 A Analog Input 20 Output power line 1 W Analog Input 21 Output power line 2 W Analog Input 22 Output power line 3 W Analog Input 23 Output frequency Hz

Analog Input 24 Output load line 1 % Analog Input 25 Output load line 2 % Analog Input 26 Output load line 3 % Analog Input 27 Battery voltage V Analog Input 28 Battery current A Analog Input 29 Battery capacity % Analog Input 30 UPS temperature C Analog Input 31 Autonomy min Analog Input 32 Nominal power VA Binary Input 0 Mains status Present/Not present Binary Input 1 Bypass status Active/Not active Binary Input 2 Battery status Working/Not working Binary Input 3 Battery level Low/Not low Binary Input 4 UPS locked Locked/Not locked Binary Input 5 UPS fail Fail/Not fail Binary Input 6 Load Overload/Normal Binary Input 7 Temperature Overtemperature/Normal Binary Input 8 Bypass bad Bad/Not bad Binary Input 9 Replace battery Replace/Not replace Binary Input 10 Shutdown Active/Not active Binary Input 11 Shutdown imminent Imminent/Not imminent Binary Input 12 Communication status Lost/OK