THE LOGAN HOUSE: MEASURING AIR MOVEMENT



Similar documents
"Sustainable Vernacular Florida Cracker?"

SIGNING OFF ON THE LOGAN HOUSE

How Do Oceans Affect Weather and Climate?

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple

Adaptive strategies for office spaces in the UK climate

BAFFLES AS A MEANS OF STATION PROTECTION FROM HIGH AIR VELOCITIES - COMPARISON OF ANALYTICAL AND FIELD MEASUREMENTS RESULTS

ELIMINATING AIR CONDITIONERS IN NEW SOUTHERN CALIFORNIA HOUSING

AIR DISTRIBUTION FOR COMFORT AND IAQ

CFD ANALYSIS CHALLENGES IN BUILDING SIMULATION FOR SIMBUILD2004 CONFERENCE. Ferdinand Schmid and Galen Burrell Architectural Energy Corporation

SOLAR ENERGY How much strikes the earth? How much can my building get? When is it too much?

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial

Geography affects climate.

CHAPTER 3. The sun and the seasons. Locating the position of the sun

Ceiling Fans. 1 Introduction. V entilation I nformation P aper n 13

Name Period 4 th Six Weeks Notes 2015 Weather

CAN DEMAND CONTROLLED VENTILATION REPLACE SPACE HEATING IN OFFICE BUILDINGS WITH LOW HEATING DEMAND?

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

CHAPTER 4 VENTILATION

Southern AER Atmospheric Education Resource

Residential Windows, 3 rd edition Corrected index 1

Aerodynamics at Volvo Car Corporation KTH 2008

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

Ventilation for Cathedral Roofs: How Much Is Sufficient?

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

2. The map below shows high-pressure and low-pressure weather systems in the United States.

Storm tide is the water level rise during a storm due to the combination of storm surge and the astronomical tide.

LIFE SCIENCE. Hoop House Construction for New Mexico: 12-ft. x 40-ft. Hoop House BRINGING TO YOUR HOME ECONOMICS COLLEGE OF AGRICULTURE AND

Residential HVAC System Sizing

Storm tide is the water level rise during a storm due to the combination of storm surge and the astronomical tide.

CHAPTER 3 Window design for day lighting, ventilation and to

Roof Inspection. Summary Report

Energy efficient home design

OWNER S MANUAL FOR THE PATIO SAUNA

Impact-Resistant Windows and Sliding Glass Doors

What Causes Climate? Use Target Reading Skills

Non Invasive Roof Leak Detection Using Infrared Thermography

SYSTEMS INTEGRATION SYSTEMS INTEGRATION. Air handler uses heat recovery on exhaust air to temper incoming ventilation air Oxbow skylight

Using Computational Fluid Dynamics (CFD) for improving cooling system efficiency for Data centers

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Design and Re-Use Of Shovadans In Today's Architecture "With Due Attention To Have Thermal Energy Of The Earth"

Thermal Analysis, Heat Sink Design and Performance Verification for GE Fanuc Intelligent Platform s WANic 3860 Packet Processor PCI Card

Fire Development and Fire Behavior Indicators

Software Development for Cooling Load Estimation by CLTD Method

Integrated Solar Radiant Systems

Net Zero Station Design for The Cooper Centre for the Environmental Learning in Tucson, Arizona: Improving the performance of existing buildings

LATITUDES INTERNATIONAL DESIGN CHALLENGE

Case Study Family Room Renovation 3br family home, Melbourne

Passive Solar Design and Concepts

Access onto roof from Center Block

CONCEPTUALIZATION OF UTILIZING WATER SOURCE HEAT PUMPS WITH COOL STORAGE ROOFS

CFD Grows Up! Martin W. Liddament Ventilation, Energy and Environmental Technology (VEETECH Ltd) What is Computational Fluid Dynamics?

The Reunion experience

Basics of vehicle aerodynamics

2013 Code_Saturne User Group Meeting. EDF R&D Chatou, France. 9 th April 2013

to encourage high quality tropical vernacular Queensland architecture throughout the Shire;

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Wind vs. Water and Unique Monroe County Mitigating Factors for Wind Damage

Unique Airflow Visualization Techniques for the Design and Validation of Above-Plenum Data Center CFD Models

Overset Grids Technology in STAR-CCM+: Methodology and Applications

MacroFlo Opening Types User Guide <Virtual Environment> 6.0

The Zig Zag Building Victoria Street, London, SW1

Accurate Air Flow Measurement in Electronics Cooling

Cool Spaces. earth-wise guide to. green strategies: light strategies: Keep Austin Cool

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

CONDENSATION IN REFRIDGERATED BUILDINGS

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

Chapter Overview. Seasons. Earth s Seasons. Distribution of Solar Energy. Solar Energy on Earth. CHAPTER 6 Air-Sea Interaction

ROOFS, SNOW AND ICE DAMS

THERMAL STRATIFICATION IN A HOT WATER TANK ESTABLISHED BY HEAT LOSS FROM THE TANK

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Housing of Robotic Telescopes Hosting

How To Model With Cfd Using Phoenics

Housing Fact Sheets. Energy Saving Window Treatments

Rooflight INSTALLATION INSTRUCTIONS

Workplace Health, Safety & Welfare

Climates are described by the same conditions used to describe

Fire is the rapid oxidation of a combustible material, releasing heat, light, smoke, and various toxic gases

Nondestructive Evaluation of USCG Hawkins Pt. Road Curtis Bay, MD Provided by: HurleyIR

NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES

NUCLEAR ENERGY RESEARCH INITIATIVE

Whole House Dehumidification for Occupant Comfort and Energy Savings

Answers to Your Questions from the Webinar

VENTILATIVE COOLING EBC ANNEX 62 PER HEISELBERG DEPARTMENT OF CIVIL ENGINEERING

5.14 COMPUTATIONAL MODELLING OF AIRFLOW IN URBAN STREET CANYON AND COMPARISON WITH MEASUREMENTS

Long-distance transport of avocados

Saving Heating Costs In Warehouses

COOKING THE ROOF CFD BEYOND THE WHITE SPACE

(1) 2 TEST SETUP. Table 1 Summary of models used for calculating roughness parameters Model Published z 0 / H d/h

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Housing Fact Sheets. Moisture Condensation at the Windows

BEST 3, Atlanta, April 2012 Grahame E. Maisey, P.E.

Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings

TechPractices: Home Front Homes:

CGC1D1: Interactions in the Physical Environment Factors that Affect Climate

Chapter 6 ROOF-CEILING SYSTEMS

Transcription:

THE LOGAN HOUSE: MEASURING AIR MOVEMENT Alison G. Kwok, Ph.D. Department of Architecture University of Oregon Eugene, OR 97403-1206 akwok@aaa.uoregon.edu Walter Grondzik, P.E. School of Architecture Florida A&M University Tallahassee, FL 32307-4200 gzik@polaris.net ABSTRACT Naturally-ventilated houses in the hot and humid climate of Florida are rapidly disappearing in the wake of airconditioned developments. As research to find ways to economize on air-conditioning systems and energy use continues, simple strategies to promote natural ventilation are not to be forgotten. Designed to promote passive cooling, the Logan House in Tampa, Florida serves as a model to counter this trend. Images of this house are often used as a teaching vehicle in environmental technology classes because the house demonstrates the principles of cross- and stack-ventilation. However, do we know how this house actually performs? More than 15 years after its construction we found the house still naturally ventilated, but wondered about the ventilation performance. What are the patterns of air movement; the resulting air velocities? Using scale-model test data from a boundary layer wind tunnel at the University of California at Berkeley and field measurements from the Logan House made by students from Florida A&M University we assessed the effectiveness of these methods in characterizing air movement and tried to understand the performance of the house. to the climatic conditions and complimented the desires of the clients with deck space, a high, central full-width common space, and was energy efficient through its promotion of natural ventilation. Fig. 1: The Logan House in Tampa, Florida after construction in 1981. (photo courtesy of the architect) 1. INTRODUCTION The Logan House is located on a federally protected tidal estuary within walking distance of the edge of Hillsborough Bay in Tampa, Florida. Because a large part of the site is flat, sandy, estuary land near the coast, the area is vulnerable to tidal surges. The Logans wanted an energy-efficient, casual house with plenty of daylight and room for entertaining. With these factors in mind, Dwight Holmes of Rowe Holmes Associates proposed a home that expressed the traditional cracker house style of Florida. It responded Completed in 1981, the house features a raised floor and a belvedere set at the peak of a steeply pitched roof that would shed water quickly. Through the stack effect mechanism, rising warm interior air could vent through clerestory windows. In theory, this natural convection current could offer some relief during hot summer months. The house sits on 10 x 10 pressure-treated posts approximately 8 ft. above ground, safely above storm flooding and also allowing air movement below the structure. Palms and live oaks surround the house providing shade and privacy, although reducing the potential for air

movement. Decks to the east and west are an integral part of the house, where guests can wander in and out of the house. Bedrooms surround the central living space and were designed using simple awning-type windows with a top hinge, which when open would promote cross-ventilation. In theory, air enters through the lower windows and open sliding doors, rises into the belvedere, and is vented to the outside (see Figure 1 for general arrangement of openings). Based on information published in various journals, the Logan House is often used as a model of energy efficiency and natural ventilation in environmental technology classes. But, how does the house actually perform? Is the house still naturally ventilated? How accurate are models at predicting patterns of air movement? The objectives of this study were to: understand the principles of air movement in and around the building; quantitatively test various methods for characterizing airflow; qualitatively assess the effectiveness of natural ventilation through patterns of air movement. 2. METHODS We used a variety of methods to compare design intent with the actual performance in the Logan House -- Figure 2 suggests the design intent for cross-ventilation. These methods included field observations/measurements and wind tunnel studies of airflow performance. The field studies used fairly simple, low-cost instrumentation devices and involved short-term measurements made during a single visit. The wind tunnel studies were made using the University of California at Berkeley Boundary Layer Wind Tunnel and a ¼ scale model. During a site visit in March 1998, conducted as part of a Vital Signs case study investigation, students from Florida A&M University took field measurements in the Logan House. The usefulness of these measurements was restricted by the limited equipment available to the students and by the excellent weather conditions encountered during the visit. The wind tunnel investigations were conducted in June 1998. Information from construction drawings provided by the architect was used to build a scale model of the house. The model enabled the visualization of simulated airflow using a white-colored smoke against the black background of the model. The observed airflow patterns in and about the model were used to determine points for hotwire anemometer measurements of interior velocities. Climate data from the online National Climatic Data Center (NCDC) were used to compare model results with anticipated on-site performance. As neither the field measurements nor the wind tunnel studies provided truly definitive information on the ventilation performance of the Logan House, efforts to identify other analysis techniques were undertaken. One potentially promising technique was computational fluid dynamics (CFD). A request for information on applying such an analysis technique to a residential building, however, led to the conclusion that this would not be a fruitful endeavor. The request, posted to the Society of Building Science Educators (SBSE) listserve, resulted in over 20 responses the majority of which indicated that CFD analysis would be very time consuming, expensive, and of little benefit in terms of fine-tuning design features of interest (such as window-hinge locations). Fig. 3: Student investigators arriving at the Logan House. 2.1. Climate Data Fig. 2: Patterns of summer airflow. (2) Tampa, Florida is located at 27 N latitude along the west central coast of the Florida Peninsula. Very near the Gulf of

Mexico at the upper end of Tampa Bay, land and sea breezes modify the subtropical climate. The climate of this area is characterized by long, warm, and humid summers, with temperatures between 70-90 F; winters are mild, with temperatures between 50-70 F (see Figure 4). Tropical storms and hurricanes are outstanding features of the Tampa climate. Relative humidity is fairly consistent, at around 70% throughout the entire year. Winds of approximately 4 m/s are experienced predominantly from the north, except during the summer months when they come from the west. Fig. 4: Annual climate data for Tampa showing minimum, maximum, and average temperatures. (3) published wind data for Tampa, Florida available from the NCDC. 2.3. Field Measurements During the spring semester of 1998, under the auspices of a case study grant from the Vital Signs Project (http://wwwarchfp.ced.berkeley.edu/vitalsigns/index.html), a studio/ technology class at Florida A&M University undertook a case study of the performance of the Logan House. (4) The class formulated a set of questions and hypotheses about air movement and comfort conditions within the house. For example, they believed that the temperature distribution throughout the house would be generally uniform, both horizontally and vertically. To test this hypothesis, students installed a PVC instrumentation pole (with Hobo temperature and humidity dataloggers attached at several heights) in the central belvedere of the Logan House to measure thermal stratification. To measure air speeds experienced in the house, the students took spot measurements with a handheld Solomat hotwire anemometer and recorded their observations on a floor plan of the house. To observe patterns of air movement, they used a bubble solution and traced the pattern of bubble movements on a sectional drawing of the house (see Figure 7). Although temperature and humidity measurements were recorded over a two-week period using the Hobo dataloggers, it was not possible to obtain longterm air velocity measurements with the equipment available. 2.2. Model and Flow Visualization Air flow patterns and spot measurements in the house were determined using a ¼ = 1-0 scale model (shown in Figure 5). The materials used to construct the model included foam core for the walls and floors, spray painted black; and transparent acrylic roofs and ceilings (drilled with holes for an anemometer probe). This type of construction allowed airflow visualization and velocity measurements to be made with some ease. Wooden blocks placed in the wind tunnel (see Figure 5) are used to simulate the roughness of the wind that corresponds to surface winds found in suburban areas. Using a wand connected to a smoke generator to develop a visible track for air flow, wind flow patterns within and surrounding the house were observed and recorded photographically. For interior velocity measurements using the hotwire anemometer probe, velocities were recorded as a percentage of the undisturbed wind speed in the test area of the wind tunnel (corresponding to a reference height of 10 m). This reference velocity can then be related to the Fig. 5: Model of the Logan House in the Boundary Layer Wind Tunnel at the College of Environmental Design, University of California, Berkeley.

3. RESULTS From the annual climate data on temperature, relative humidity, and wind speed, a climate analysis shows the potential for natural ventilation in the Tampa area to be excellent. The new owners of the Logan House indicated that temperatures were very cool even during the summer; however, at the time of this study, they had only occupied the house for short time. To our surprise, we learned that the architect specified two air-conditioning units in the original design, which the Logans used intermittently during the summer as many Floridians must (2). As expected, smoke patterns in the wind tunnel tests (Figure 6) indicated that that the central space seemed to draw air effectively through the building when the top windows in the belvedere and the bottom doors adjacent to the deck were open. The smoke visualization test revealed a relatively large portion of the oncoming wind being deflected by the roof, rather than flowing substantially through the lower openings and up through the central belvedere. However, the house did perform well when the high-level openings in the belvedere were open, the lowerlevel openings were all open, and the wind direction was normal to the patio door openings. In another position, with the top windows closed and the bottom doors open, patterns of airflow were less directional and slightly turbulent. To check this observation, an omni-directional anemometer was lowered into the central space of the model. Table 1 shows the resulting readings from the wind tunnel data acquisition system, verifying our observations. Interior air speeds averaged 0.67 m/s with the top windows closed and 0.74 with the top windows open. An interesting outcome of the wind tunnel studies was the observation of the striking aerodynamics of the bulk form of the Logan House. Airflow around and over the house (at least in the model) was exceptionally smooth, almost as one would expect around a well-designed car, even though the profile of the house is not rounded or continuous (see Figure 6). It is possible that this feature, never likely to be observed in on-site visits or experiences, actually works against crossventilation effectiveness by channeling winds over the house instead of through the house. The bubble test conducted during the on-site visit did not clearly validate the stack effect principle (by showing warm air rising). It is possible that the bubble solution was too heavy to demonstrate thermal buoyancy or it was simply too comfortable a day for such an effect to be visible. The students did, however, observe many bubbles travelling across the central living space and falling to the ground floor at the stairway (Figure 7) where there was measurably cooler air. As an aside, the bubble test proved to be a crowd-pleaser. These qualitative measurements combined with on-site velocity measurements showed the fastest and most turbulent air velocities occurred nearest the open doors. There was virtually no air movement in the central space just below the belvedere (Figure 8). Fig. 6: Airflow pattern around Logan House model; the top is a visual image, the bottom a representation developed from a digital camera image. Fig. 7: Students blowing bubbles and measuring air speed with an anemometer.

Fig. 8: Plan of the Logan House showing spot velocity measurements taken onsite with a hotwire anemometer in March 1998, with belvedere windows closed and side doors open. TABLE 1: WIND TUNNEL (SCALE MODEL) VELOCITY TEST RESULTS Design Condition Trial Measured Velocity (m/s) Velocity Ratio (%) * Top Closed & 1 0.73 11.54 Bottom Open 2 0.70 11.02 3 0.57 8.94 4 0.69 10.87 Top Open & 1 0.70 10.99 Bottom Open 2 0.82 12.95 3 0.70 11.03 4 0.79 12.46 5 0.69 10.84 * Velocity ratio = mean interior velocity divided by the mean reference ( ambient ) velocity. The mean reference velocity was approximately 6.3 m/s. Another interesting outcome of the on-site field measurements is that the students were able to verify the asbuilt design with the original drawings. We discovered (when building the model) that the original plans showed an additional floor below the belvedere, a feature that would have substantially changed the house s ability to ventilate through the belvedere clerestories. 4. SUMMARY One interesting, and un-nerving, outcome of this series of investigations is an increased awareness of the difficulties facing designers of passive systems. Even with tools not normally used during the design process wind tunnel studies and visits to a completed building it was exceptionally difficult to get a handle on the performance of this building under design conditions. Questions directly related to the design features of the building such as the best type of window to use on the lower floor and whether a top- or a bottom-hinged belvedere window made more sense when designing for natural ventilation were resistant to analysis through site visits and any reasonably-feasible scale model study. Computational fluid dynamics may fill this analysis void in the future, but the technologies for such analyses are

apparently not yet developed to the point where they could be described as user-friendly design tools. 5. ACKNOWLEDGEMENTS We acknowledge the generosity of the Hepners, new owners of the Logan House, who shared their house with the Florida A&M students during the case study, allowing poles, dataloggers, and instrumentation to be strewn in various locations for a period of time. Their interest in connecting design intent to performance helps perpetuate traditional designs that shouldn t be forgotten. Support from the Vital Signs Project at the University of California Berkeley made the case study possible. We also are grateful for the use of the Boundary Layer Wind Tunnel at the Center for Environmental Design Research at the University of California, Berkeley and for the assistance in the use of the tunnel provided by Ph.D. candidate, Zhang Hui. 6. REFERENCES (1) Brown, G.Z., Sun, Wind, and Light: Architectural Strategies, New York: John Wiley & Sons, 1985 (2) Alvarez, Mark. Florida Cracker House: an indigenous form returns in style, Fine Homebuilding, June/July 1981, p.55-59 (3) NOAA, Local Climatological Data, Annual Summary with Comparative Data for Tampa, National Climatic Data Center: <http://www.ncdc.noaa.gov/ol/ncdc.html> (4) Case Studies of Four Florida Houses, a set of Vital Signs case studies (various authors), Florida A&M University, School of Architecture: <http://www99.pair.com/vsfamu/4house/index.htm>