Allen Goldstein NIST Synchrometrology Lab Gaithersburg, MD allen.goldstein@nist.gov



Similar documents
PHASOR MEASUREMENT UNIT (PMU) AKANKSHA PACHPINDE

System Protection Schemes in Eastern Denmark

Wide Area Monitoring, Control, and Protection

ETHERNET TIME & SYNC. In Telecoms, Finance, Power, Broadcast,... ITSF Nice, 6 Nov 2012

Synchronized real time data: a new foundation for the Electric Power Grid.

Wide Area Monitoring Current Continental Europe TSOs Applications Overview

Smart Grid: Concepts and Deployment

Everything you need for protection scheme testing

Welcome. Enabling Wide Area Monitoring, Protection, and Control (WAMPAC) Systems with and the Importance of Time Synchronization

Panel Session: Lessons Learned in Smart Grid Cybersecurity

STATEMENT OF PATRICIA HOFFMAN ACTING ASSISTANT SECRETARY FOR ELECTRICITY DELIVERY AND ENERGY RELIABILITY U.S. DEPARTMENT OF ENERGY BEFORE THE

Delivering NIST Time to Financial Markets Via Common-View GPS Measurements

T200, PTP/IEEE 1588 Grandmaster Clock and

Power System review W I L L I A M V. T O R R E A P R I L 1 0,

Opportunities to Overcome Key Challenges

General GPS Antenna Information APPLICATION NOTE

Smart Grid America: Securing your network and customer data. Michael Assante Vice President and Chief Security Officer March 9, 2010

Hybrid processing of SCADA and synchronized phasor measurements for tracking network state

BIGDATAANALYTICS FOR ELECTRICPOWERGRID OPERATIONS MANU PARASHAR CORPORATE POWER SYSTEMS ENGINEER JULY 29, 2015

1. Introduction Synchrophasor Technologies... 1

Electric utilities may vary in their application of end-to-end testing

Synchrophasors Redefining SCADA Systems

Communication and Embedded Systems: Towards a Smart Grid. Radu Stoleru, Alex Sprintson, Narasimha Reddy, and P. R. Kumar

APPLICATION CASE OF THE END-TO-END RELAY TESTING USING GPS-SYNCHRONIZED SECONDARY INJECTION IN COMMUNICATION BASED PROTECTION SCHEMES

OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories:

ECE 586b Course Project Report. Auto-Reclosing

Big Data and Advanced Analytics Technologies for the Smart Grid

Application of Synchrophasor Data to Power System Operations

Executive Summary... ii

Indoor / Outdoor Antenna

REAL TIME DYNAMICS MONITORING SYSTEM (RTDMS ) AND PHASOR GRID DYNAMICS ANALYZER (PGDA) USER TRAINING FOR ERCOT

Synchronization and precise timing in packet networks

Securing GNSS with PTP & SyncE Adam Wertheimer Microsemi Adam.Wertheimer@microsemi.com. Power Matters

Time Calibrator Fountain Computer Products

Big Data: Using Smart Grid to Improve Operations and Reliability. LaMargo Sweezer-Fischer Power Delivery Grid Automation Manager FPL July 2014

Precision Time Protocol (PTP/IEEE-1588)

Topic 2: Introduction to Smart Grid

Evaluating the Accuracy of Maxim Real-Time Clocks (RTCs)

IEEE Standards Activities in the Smart Grid Space (ICT Focus)

Best Practices for Creating Your Smart Grid Network Model. By John Dirkman, P.E.

Toward standards for dynamics in future electric energy systems The basis for plug and play industry paradigm

Remote Calibration of a GPS Timing Receiver to UTC(NIST) via the Internet*

Standards for smart grids with emphasis on their realization in remote and rural areas

San Diego Gas & Electric Company FERC Order 717 Transmission Function Employee Job Descriptions August 10, Electric Grid Operations

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

Synchrophasor projects: STRONgrid and SPANDEx

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Risk Management, Equipment Protection, Monitoring and Incidence Response, Policy/Planning, and Access/Audit

Energy Systems Integration

SCADA Systems Automate Electrical Distribution

White Paper. Convergence of Information and Operation Technologies (IT & OT) to Build a Successful Smart Grid

Power network telecommunication

Clocks/timers, Time, and GPS

MODERN TECHNOLOGIES FOR POWER SYSTEMS MONITORING

Next Generation Grid Data Architecture & Analytics Required for the Future Grid

VoIP Timing and Synchronization Best Practices

DOE/OE Transmission Reliability Program. Data Validation & Conditioning

)454 6 %,%#42)#!, #(!2!#4%2)34)#3 &/2 5."!,!.#%$ $/5",%#522%.4 ).4%2#(!.'% #)2#5)43 $!4! #/--5.)#!4)/. /6%2 4(% 4%,%0(/.%.%47/2+ )454 Recommendation 6

Secure Machine to Machine Communication on the example of Smart Grids

HANDBOOK. Measuring System DESIGN EDITORS PETER H. SYDENHAM RICHARD THORN ARTICLE OFFPRINT

Copyright. Deepak Mohan

TIMING SIGNALS, IRIG-B AND PULSES

Electrical/Electronic Engineering Technologist DACUM Facilitated by Craig Edwards and Sandra Sukhan April 15 th and 20 th 2011

POWER PURCHASE AGREEMENT FOR ROOFTOP SOLAR PV PLANTS WITH NET METERING ARRANGEMENT

Application-oriented testing of line differential protection end to end in the field using the corresponding RelaySimTest template

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Latency on a Switched Ethernet Network

WHITE PAPER. Packet Time Monitoring in Your Visibility Architecture

Smart Grid Demonstration Lessons & Opportunities to Turn Data into Value

ABB North America. Substation Automation Systems Innovative solutions for reliable and optimized power delivery

Project description. Power Electronics for Reliable and Energy efficient Renewable Energy Systems

Industrial Ethernet How to Keep Your Network Up and Running A Beginner s Guide to Redundancy Standards

Real Time Test Bed Development for Power System Operation, Control and Cyber Security

Time Synchronization & Timekeeping

Cyber Infrastructure for the Smart Grid

ENVIRONMENTAL MONITORING SYSTEM WITH WORLD-WIDE COVERAGE AND BIDIRECTIONAL COMMUNICATION VIA INMARSAT SATELLITE NETWORK

Considerations for Use Of Disturbance Recorders

Computer Time Synchronization

Performance Evaluation of Linux Bridge

Smart Grid. Hva er Smart Grid og hva er det ikke? Tore Langeland/Christopher Greiner 26 oktober 2010

Industrial IT for Substation Automation & Protection

MAINTAINING SYSTEM BLACKSTART IN COMPETITIVE BULK-POWER MARKETS

Infrastructure Interdependencies

Agenda do Mini-Curso. Sérgio Yoshio Fujii. Ethan Boardman.

Current Probes. User Manual

Risk of Large Cascading Blackouts

Transcription:

Time Synchronization in Electrical Power Transmission and Distribution Systems Allen Goldstein NIST Synchrometrology Lab Gaithersburg, MD allen.goldstein@nist.gov

Abstract Synchronization of measurements in electrical power systems with Coordinated Universal Time (UTC) is expected to become mission critical worldwide over the next few years. This paper describes some of the applications for time-synchronized measurements, the requirements for accuracy and reliability, the ways timing information is received and distributed in electrical substations, and the risks which must be mitigated before the power system becomes reliant on time synchronization. It explains the need for alternative time synchronization sources redundant with Global Positioning System (GPS). 2

Time Synchronized Measurements multiple spatially distributed measurements which are synchronized to occur within a specified window of time transmitted and then collected at one or more locations and aligned in time increasingly being used in electrical power systems worldwide not a new concept or application in electrical power systems as technology advances, the time frame of synchronized information has been steadily reduced from minutes to seconds, milliseconds, and now microseconds applications: SCADA/EMS disturbance monitoring/recording fault location synchrophasors 3

Accuracy requirements SCADA/EMS (state estimation): one to three seconds Disturbance monitoring/recording: within 2 milliseconds of UTC specified by the National Energy Reliability Corporation (NERC). NERC is the U.S. regulatory agency for the energy sector Fault Location Devices: less than about 1.7 microseconds travelling wave locators rely on the difference in clocks at either end of a fault. fault signal travels at approximately the speed of light 1.7 microseconds equals about 500 meter uncertainty in the location of the fault 4

Synchrophasors 5 Phasor measurement units (PMUs) measure power system voltages and currents and estimate the synchrophasor of each phase Synchrophasors are a polar or rectangular representation of the power system amplitude and phase compared to a theoretical signal at the power system nominal frequency synchronized to UTC The reporting rates from the PMU can be from one report per second to 120 reports per second. Typical reporting rates are 10, 20, 30 or 60 reports per second in 60 Hz power systems; 10, 25 or 50 reports per second in 50 Hz power systems Synchrophasor data from multiple PMUs are aggregated at remote locations and can provide a real-time measurement of the system state.

Synchrophasor accuracy The maximum allowed error for PMU measurements is 1 % total vector error (TVE) PMU performance limits are specified by IEEE Standard C37.118.1-2011, revised by IEEE C37.118.1a-2014 The total vector error combines both the phase error and magnitude error into a single scalar value which is the magnitude of the vector between the measured synchrophasor value and the true value (the actual input to the PMU) Equation 1: Total Vector Error [6] TVE( n) = 2 ( Xˆ ( ) ( )) ˆ r n X r n + X i ( n) X i ( n) 2 ( X ( n) ) + ( Xi( n) ) 2 ( ) ( ) r Figure 1: Graphical depiction of synchrophasor error 2 6

Effect of time accuracy on synchrophasors For a 50 Hz or 60 Hz power system, a 0.573 (0.01 rad) error (with 0 magnitude error) would yield a 1 % TVE. A 0.573 phase error could be caused by a 26.53 µs time error for a 60 Hz system or a 31.83 µs timing error for a 50 Hz system This leaves no room for magnitude error The recommended time accuracy for synchrophasors is 1 µs [4]. All synchrophasor measurements at a particular time should be made within 1 µs of each other. The phase accuracy is a function of the frequency of the voltage or current being measured and the time accuracy. For a 60 Hz measurement, a 1 µs error would yield a 0.377 mrad (21.6 mdeg) error, and for a 50 Hz measurement the error would be 0.314 mrad (18 mdeg) 7

Synchrophasors future The synchrophasor standard is being revised by a joint IEEE/IEC working group considering new applications expects to publish a joint synchrophasor standard: IEEE/IEC 60255-118-1 sometime before 2018 applications which require better than 1 % TVE are being considered A Department of Energy ARPA-E program is investigating applications for a micro-pmu (µpmu) extremely precise time-stamping of measurements to allow comparisons of voltage phase angle down to small fractions of a degree may be beneficial in distribution networks where the phase differences between nodes are smaller µpmu technology is expected to discern angle differences to significantly better than ± 0.05 deg (aiming for ±0.01 deg) the maximum timing error would need to be less than 0.463 µs for a 60 Hz system or 0.557 µs for a 50 Hz system 8

other synchrophasor timing requirements A time-synchronous measurement device calibration system should be at least 10 times as accurate as the measurement system under test (20 times more accurate is preferable). A phase accuracy of 87 µrad (0.005 deg) is the recommended target accuracy. Table 1: Phase error and TVE contribution of timing errors timing error phase error (60 Hz) TVE contribution 26.53 µs 0.01 rad (0.573 deg) 1% 1 µs 0.3 mrad (0.022 deg) 0.04% 0.463 µs 0.17 mrad (0.01 deg) 0.02% 0.231 µs 87 µrad (0.005 deg) 0.01% The difference between the calibration system s time and the device-under-test s time must be small. If so, the time difference with UTC does not matter 9

Reliability requirements NERC publishes reliability standards for the bulk electric systems of North America numerous standards which are required to be met by power system designers and operators. For many systems considered essential to the reliability of the bulk power system, redundant systems are required. For example, in Standard COM-0011.1 Telecommunications: Each reliability coordinator, transmission operator, and balancing authority is responsible to provide adequate and reliable telecommunications facilities for the exchange of interconnection and operating information. At this time, there are no NERC requirements for redundancy in time-synchronization facilities Notably, requirement R2 of the NERC cyber security standards states: The (standards drafting team) understands that there may be some Cyber Assets where automated monitoring may not be possible (such as a GPS time clock). For that reason, automated technical monitoring was not explicitly required and a responsible Entity may choose to accomplish this requirement through manual procedural controls Where applicable, these facilities shall be redundant and diversely routed 10

Time reception 11 GPS as Today s Only Option PMUs should maintain 1 µs accurate synchronization with UTC and may be located almost anywhere in the world. satellite-based time synchronization is the only option available today, and GPS is the only system presently being used for timing. Other satellite systems are being developed. These include GLONASS, Galileo, and BeiDou. research is needed into the plausibility of using other sources of 1 µs accurate UTC time to provide a redundant, diversely routed source of time signal. In the United States, NERC creates standards for power system reliability, and power system operators must comply with the standards. most of the mission critical power system components are required to be redundant and diversely routed. PMUs today are not considered mission critical components of the power system. however, demands on the system are changing with new loads such as electric vehicle charging and synchronous DC motors. furthermore, new energy sources such as wind and solar power are becoming distributed across transmission systems and even across distribution systems which were not originally designed for bidirectional power flow. based on synchronized measurements, PMUs are widely expected to become mission critical over the next 5 to 10 years.

Time distribution Depending on the manufacturer and model of the device, the time-synchronizing source input may be: GPS antenna input, Inter Range Instrumentation Group (IRIG) standard 200-04 [11] input (sometimes also requiring a digital pulse per second (PPS) input) or for some newer equipment, an IEEE 1588 Precision Time Protocol (PTP) delivered via Ethernet as specified by the Power Profile GPS Antennas and Splitters Many devices containing PMU functions include their own GPS receivers. input is often a coaxial cable directly from a remotely located GPS antenna or a GPS antenna splitter. EMI, impedance matching, and cable delay are issues that can contribute to time synchronization errors or loss of lock. 12

Risks 13 Today s Risk is Low today s applications of timesynchronized power system measurements are not considered mission critical. applications in use today include: power system base-lining event analysis, model verification, transient analysis, fault location, restoration, modal (oscillation) analysis, and state estimate verification. None of these applications is solely dependent on PMU data; as a consequence, a loss of PMU data is highly unlikely to contribute directly to a system outage or blackout. Tomorrow s Risk is Uncertain time-synchronized measurement applications are being researched by power system operators, utilities and government laboratories. include: real-time system protection applications, real-time generator control, real-time frequency and voltage control, load shedding, intentional islanding control, many others. which of these applications may be implemented in the electrical system and the time frame is uncertain at this time using time-synchronized measurements for the above applications could: prevent large system outages restore the system faster if outages do happen. these applications depend on PMUs: failure or sabotage of the timesynchronizing source signal could introduce vulnerabilities that have the potential to degrade the grid operation or damage equipment.

Conclusion Before time-synchronized measurement becomes mission critical on the power system, it is likely that measurement systems will be required to have redundant and diversely routed synchronizing time sources. Thank you Allen Goldstein NIST Synchrometrology Lab Gaithersburg, MD allen.goldstein@nist.gov 14