Sun StorEdge A5000 Installation Guide



Similar documents
N1 Grid Service Provisioning System 5.0 User s Guide for the Linux Plug-In

Sun StorEdge RAID Manager Release Notes

Sun Management Center Change Manager Release Notes

Sun Enterprise Optional Power Sequencer Installation Guide

Upgrading the Solaris PC NetLink Software

Optimizing Solaris Resources Through Load Balancing

Sun Cluster 2.2 7/00 Data Services Update: Apache Web Server

Solaris 10 Documentation README

Service Level Definitions and Interactions

Sun Enterprise 420R Server Product Notes

Sun StorEdge N8400 Filer Release Notes

Sun StorEdge T3 Dual Storage Array - Part 1

Scrubbing Disks Using the Solaris Operating Environment Format Program

Comparing JavaServer Pages Technology and Microsoft Active Server Pages

SunFDDI 6.0 on the Sun Enterprise Server

Solaris Bandwidth Manager

Sun StorEdge Availability Suite Software Point-in-Time Copy Software Maximizing Backup Performance

Solaris 9 9/05 Installation Roadmap

Sun Management Center 3.6 Version 5 Add-On Software Release Notes

JumpStart : NIS and sysidcfg

Service Level Agreement in the Data Center

LAN-Free Backups Using the Sun StorEdge Instant Image 3.0 Software

Java Dynamic Management Architecture for Intelligent Networks

Exploring the iplanet Directory Server NIS Extensions

Managing NFS Workloads

Reducing the Backup Window With Sun StorEdge Instant Image Software

Sun Ultra TM. 5 and Ultra 10 Product Notes. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA U.S.A.

Sun TM SNMP Management Agent Release Notes, Version 1.6

Sun StorEdge Enterprise Backup Software 7.2

Power Savings in the UltraSPARC T1 Processor

Disaster Recovery Requirements Analysis

Developing a Security Policy

Sun Management Center 3.5 Update 1b Release Notes

HelloWorld SOAP Sample:

Important Note on New Product Names

Sun StorEdge Network FC Switch-8 and Switch-16 Release Notes

Sun Fire 6800/4810/4800/ 3800 Systems Product Notes

Sun Management Center 3.6 Version 4 Add-On Software Release Notes

Sun Fire 6800/4810/4800/3800 Systems Software Release Notes

Rapid Recovery Techniques: Exploring the Solaris Software Registry

SCSI Sense Key Error Guide

Sun SNMP Management Agent Release Notes, Version 1.5.5

Solaris Resource Manager

Start Here. Installation and Documentation Reference. Sun StorEdgeTM 6120 Array

RAID Controller PCI Card for the Sun Fire V60x and V65x Servers Release Notes

Service Level Management in the Data Center

Sun Grid Engine Release Notes

The UltraSPARC T1 Processor - High Bandwidth For Throughput Computing

N1 Grid Engine 6 Release Notes

Consolidation in the Data Center

Rapid Recovery Techniques: Auditing Custom Software Configuration

Sun StorEdge RAID Manager 6.22 User s Guide

Sun Fire B10n Content Load Balancing Blade Product Notes

Data Center Design Philosophy

The Solaris Fingerprint Database - A Security Tool for Solaris Operating Environment Files

Java Management Extensions SNMP Manager API

Brocade SilkWorm 4100 FC Switch Release Notes

Sun StorEdge Instant Image 3.0 and Oracle8i Database Best Practices

Sun StorEdge SAN Foundation Release Notes

Solaris 9 Installation Roadmap

SunPCi Supporting Highly Available PC Applications with Solaris

Sun Microsystems, Inc Garcia Avenue Mountain View, CA FAX

Sun Fire 6800/4810/4800/3800 Systems Firmware Release Notes

Sun StorEdge network FC switch-8 and switch-16 Release Notes

Sun Ray, Smart Cards, and Citrix

Automating Centralized File Integrity Checks in the Solaris 10 Operating System

Netra Data Plane Software Suite 2.0 Update 2 Release Notes

Sun Remote System Control (RSC) Installation Guide

Trust Modeling for Security Architecture Development

Sun Fire V480 Server Product Notes

Sun Fire Midframe Server Best Practices for Administration

Sun 450 MHz UltraSPARC -II Module Upgrade

Sun Fire V20z Server Release Notes

Distributed Application Management using Jini Connection Technology

Brocade 5300 Switch Hardware Release Notes

Brocade 300 Switch Hardware Release Notes

Sun Cobalt Control Station. Using the LCD Console

Sun N1 Service Provisioning System User s Guide for Linux Plug-In 2.0

Sun Blade 1500 Workstation Product Notes

Sun StorEdge FC-100 Long Wave Gigabit Interface Converter Guide

Sun Ray Server Software 3 Release Notes

Using Linux mdadm Multipathing with Sun StorEdge Systems

MIGRATION WHITEPAPER MIGRATING FROM MICROSOFT OFFICE TO OPENOFFICE.ORG OR STAROFFICE 9

Solaris Volume Manager Administration Guide

Netra X4200 M2 Server Site Planning Guide

Operations Management Capabilities Model

Sun Blade 100 and Sun Blade 150 Workstations

Platform Notes: The SunHSI/P Device Driver

A Strategy for Managing Performance

Sun GlassFish Enterprise Manager SNMP Monitoring 1.0 Installation and Quick Start Guide

Getting StartedWith Sun Java System Application Server 9.1 Update 2

Transcription:

Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No. 805-7273-11 October 1998, Revision A Send comments about this document to: docfeedback@sun.com

Copyright 1998 Sun Microsystems, Inc., 901 San Antonio Road Palo Alto, CA 94303 USA. All rights reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Third-party software, including font technology, is copyrighted and licensed from Sun suppliers. Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in the U.S. and other countries, exclusively licensed through X/Open Company, Ltd. Sun, Sun Microsystems, the Sun logo, AnswerBook, SunDocs, Solaris, and StorEdge are trademarks, registered trademarks, or service marks of Sun Microsystems, Inc. in the U.S. and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the U.S. and other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements. RESTRICTED RIGHTS: Use, duplication, or disclosure by the U.S. Government is subject to restrictions of FAR 52.227-14(g)(2)(6/87) and FAR 52.227-19(6/87), or DFAR 252.227-7015(b)(6/95) and DFAR 227.7202-3(a). DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON- INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. Copyright 1998 Sun Microsystems, Inc., 901 San Antonio Road Palo Alto, CA 94303 Etats-Unis. Tous droits réservés. Ce produit ou document est protégé par un copyright et distribué avec des licences qui en restreignent l utilisation, la copie, la distribution, et la décompilation. Aucune partie de ce produit ou document ne peut être reproduite sous aucune forme, par quelque moyen que ce soit, sans l autorisation préalable et écrite de Sun et de ses bailleurs de licence, s il y en a. Le logiciel détenu par des tiers, et qui comprend la technologie relative aux polices de caractères, est protégé par un copyright et licencié par des fournisseurs de Sun. Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l Université de Californie. UNIX est une marque déposée aux Etats-Unis et dans d autres pays et licenciée exclusivement par X/Open Company, Ltd. Sun, Sun Microsystems, le logo Sun, AnswerBook, SunDocs, Solaris, et StorEdge sont des marques de fabrique ou des marques déposées, ou marques de service, de Sun Microsystems, Inc. aux Etats-Unis et dans d autres pays. Toutes les marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc. aux Etats-Unis et dans d autres pays. Les produits portant les marques SPARC sont basés sur une architecture développée par Sun Microsystems, Inc. L interface d utilisation graphique OPEN LOOK et Sun a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun reconnaît les efforts de pionniers de Xerox pour la recherche et le développement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique. Sun détient une licence non exclusive de Xerox sur l interface d utilisation graphique Xerox, cette licence couvrant également les licenciés de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences écrites de Sun. CETTE PUBLICATION EST FOURNIE "EN L ETAT" ET AUCUNE GARANTIE, EXPRESSE OU IMPLICITE, N EST ACCORDEE, Y COMPRIS DES GARANTIES CONCERNANT LA VALEUR MARCHANDE, L APTITUDE DE LA PUBLICATION A REPONDRE A UNE UTILISATION PARTICULIERE, OU LE FAIT QU ELLE NE SOIT PAS CONTREFAISANTE DE PRODUIT DE TIERS. CE DENI DE GARANTIE NE S APPLIQUERAIT PAS, DANS LA MESURE OU IL SERAIT TENU JURIDIQUEMENT NUL ET NON AVENU.

Contents 1. Introduction 1-1 About this Guide 1-1 Product Deliverables 1-2 Prerequisites 1-2 Hardware Requirements 1-2 Software Requirements 1-2 Recommended Documentation 1-3 Configuration Restrictions 1-3 2. Installation 2-1 Configuring the Disk Array 2-1 Connecting the Disk Array to the Windows NT Host 2-2 Configuring the Fibre Channel Host Bus Adapter 2-3 Installing the Fibre Channel Driver on the Windows NT Host 2-4 Verifying Configuration of the Host Bus Adapter Driver and Physical Disks 2-8 iii

iv Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 October 1998

Figures FIGURE 2-1 SCSI Adapters window 2-4 FIGURE 2-2 Drivers Tab of SCSI Adapters window 2-5 FIGURE 2-3 Install Driver window 2-6 FIGURE 2-4 Install From Disk window 2-7 FIGURE 2-5 List of SCSI Devices 2-9 Figures v

vi Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 October 1998

Tables TABLE 1-1 Configuration Restrictions 1-3 Tables vii

viii Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 October 1998

CHAPTER 1 Introduction This chapter gives an overview of the Sun StorEdge A5000 Disk Array for Windows NT and lists the hardware and software prerequisites. About this Guide page 1-1 Product Deliverables page 1-2 Prerequisites page 1-2 Configuration Restrictions page 1-3 About this Guide The Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 provides installation and setup information for connecting a Sun StorEdge A5000 Disk Array to a Windows NT server. Included is information for performing the following tasks: Connecting the Disk Array to the Windows NT Host on page 2-2 Configuring the Fibre Channel Host Bus Adapter on page 2-3 Installing the Fibre Channel Driver on the Windows NT Host on page 2-4 Verifying Configuration of the Host Bus Adapter Driver and Physical Disks on page 2-8 1-1

Product Deliverables The Sun StorEdge A5000 for Windows NT Server 4.0 software (Order Number A5000-NT4-B) is an option to the Sun StorEdge A5000 Disk Array and consists of the following: an Installation CD-ROM containing the Fibre Channel device driver User documentation: Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 (this document) any readme files on the Installation CD-ROM Prerequisites Before installing this product, make sure that you have the following: Hardware Requirements page 1-2 Software Requirements page 1-2 Recommended Documentation page 1-3 Hardware Requirements The following hardware is required: A Sun StorEdge A5000 Disk Array A Sun StorEdge PCI FC-100 Host Adapter (Order Number X6729A) An NT server with an empty PCI slot for the Fibre Channel Host Bus Adapter card Software Requirements You must have the Windows NT Server 4.0 or Windows NT Server 4.0 Enterprise Edition operating system with Microsoft Service Pack 3 installed on your host machine. Note This product was tested with, and requires, Microsoft Service Pack 3. 1-2 Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 October 1998

Recommended Documentation In the course of installing, configuring, and using the Sun StorEdge A5000 Disk Array for Windows NT, you may find it useful to refer to the documentation that came with the following: your disk array (especially the Sun StorEdge A5000 Hardware Configuration Guide and the Sun StorEdge A5000 Installation and Service Manual) your server the Windows NT operating system (especially the Microsoft Windows NT Server Start Here: Basics and Installation manual and your disk administration documentation, such as the Microsoft Windows NT Technical Support manual) Configuration Restrictions You should be aware of the following configuration restrictions when planning the connection between your NT server and the Sun StorEdge A5000 Disk Array: TABLE 1-1 Configuration Restrictions Maximum number of active disk arrays per host 4 Maximum number of active disk arrays per host bus adapter 1 Maximum number of active host connections per Fibre Channel loop 2 Maximum number of active host connections per disk array 2 Chapter 1 Introduction 1-3

1-4 Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 October 1998

CHAPTER 2 Installation This chapter describes how to install the Sun StorEdge A5000 Disk Array for Windows NT. The installation process consists of the following tasks: 1. Configuring the Disk Array page 2-1 2. Connecting the Disk Array to the Windows NT Host page 2-2 3. Configuring the Fibre Channel Host Bus Adapter page 2-3 4. Installing the Fibre Channel Driver on the Windows NT Host page 2-4 5. Verifying Configuration of the Host Bus Adapter Driver and Physical Disks page 2-8 Configuring the Disk Array Use the information in Sun StorEdge A5000 Installation and Service Manual and the Sun StorEdge A5000 Hardware Configuration Guide to configure the disk array. 2-1

Connecting the Disk Array to the Windows NT Host Physically connect the disk array to your Windows NT host system: Note For help with this task, refer to steps 1, 2, 3, 5, 6, and 7 in Connecting Fibre Optic Cables on page 2-4 of the Sun StorEdge A5000 Installation and Service Manual. (Step 4 of that procedure does not apply to Windows NT.) 1. Power off your Windows NT host system and your disk array. 2. Install the Fibre Channel host bus adapter in an empty PCI slot in your host. 3. Attach the disk array using the fibre cables that came with it. 4. Continue with the next section, Configuring the Fibre Channel Host Bus Adapter. 2-2 Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 October 1998

Configuring the Fibre Channel Host Bus Adapter Configure the Fibre Channel host bus adapter, if applicable: 1. Power on your Windows NT host and your disk array. If you see a message prompting you to press Alt-Q to launch the Qlogic Fast!UTIL, your Fibre Channel host bus adapter has BIOS on it. Continue with this procedure to configure your host bus adapter. If you don t see such a message, proceed to next section, Installing the Fibre Channel Driver on the Windows NT Host on page 2-4. 2. Respond to the prompt by pressing Alt-Q. 3. Select Configuration Settings and then press Enter. 4. Select Host Adapter Settings and then press Enter. 5. Select Host Adapter BIOS and make sure that the setting is Disabled; if necessary, press the Enter key to toggle the setting. (Disabling the host adapter BIOS disables the ROM BIOS and frees space in upper memory.) 6. Press the Escape key twice. 7. Select Save Changes and then press Enter. 8. Select Exit Fast!UTIL and then press Enter. 9. Select Reboot system and then press Enter. 10. Continue with the next section, Installing the Fibre Channel Driver on the Windows NT Host. Chapter 2 Installation 2-3

Installing the Fibre Channel Driver on the Windows NT Host After the host reboots the operating system, proceed as follows to install the Fibre Channel driver. 1. Select Start Settings Control Panel SCSI Adapters. FIGURE 2-1 shows a typical SCSI Adapters window. FIGURE 2-1 SCSI Adapters window 2-4 Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 October 1998

2. From the SCSI Adapters window, select the Drivers tab. FIGURE 2-2 shows a typical Drivers listing. FIGURE 2-2 Drivers Tab of SCSI Adapters window Chapter 2 Installation 2-5

3. Click the Add button below the list of installed drivers. FIGURE 2-3 shows the Install Driver window. FIGURE 2-3 Install Driver window 2-6 Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 October 1998

4. Click the Have Disk button. FIGURE 2-4 shows the Install from Disk window. FIGURE 2-4 Install From Disk window 5. Specify the location of the driver files: a. Insert the Installation CD-ROM into the drive. b. Click Browse, select your CD-ROM drive, and then specify the path: /Qla2100F/Nt/Oemsetup c. Click OK. d. Select the driver and then click OK. 6. Reboot the system so that your changes will take effect: a. When prompted, click Yes to restart. b. Click OK in the SCSI Adapters window. 7. Continue with the next section, Verifying Configuration of the Host Bus Adapter Driver and Physical Disks. Chapter 2 Installation 2-7

Verifying Configuration of the Host Bus Adapter Driver and Physical Disks Verify that your Windows NT host can see the Sun StorEdge A5000 disks. 1. Select Start Settings Control Panel SCSI Adapters. 2. Click on the entry for the QLogic QLA2000/QLA2100 host bus adapter and then click on the (+) to the left of the Bus number. Note Under certain circumstances, the SCSI Adapters utility under the Control Panel may not report accurate information. If the QLogic host bus adapter and disks are not displayed in the Devices tab of the SCSI Adapters window, select the Drivers tab and verify that the QLogic QLA2000/QLA2100 driver is started; if the driver is not started, contact your Customer Service representative for troubleshooting assistance. If the QLogic driver is started, run the Windows NT Disk Administrator and verify that it correctly displays the number and sizes of all your disks. 3. As shown in FIGURE 2-5, you should see each device that is attached to the Fibre Channel host bus adapter. (In this case, you will see all of the devices that your disk array contains.) 2-8 Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 October 1998

FIGURE 2-5 List of SCSI Devices 4. Once the disks are recognized, use the Windows NT Disk Administrator to configure the logical disks as desired. Note For help with this task, refer to your documentation about Windows NT disk administration (for example, the Microsoft Windows NT Technical Support manual). Chapter 2 Installation 2-9

2-10 Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 October 1998