PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION



Similar documents
CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

XP Series Balances Operation Manual

Operating instructions Platform/floor scales

ADVANCED INTERNET DOWNLOADABLE POSTAL & SHIPPING SCALE

SERVICE MANUAL Valor 3000 SCALES

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.

BW-500 BED WEIGHER USER MANUAL

ACS-3S/NEW SU ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL

High precision counting scale. Operation Manual. l RCZ-A Series

Operation manual Analytical and precision balances

Instruction Manual FL

SATEX SA Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg DA Zeewolde HOLLAND

Adam Equipment. CPWplus. RANGE OF SCALES (P.N. 9009, Rev. C, June 2008)

Model 349KLX Remote Display Digital Scale User Instructions

Appendix C. Vernier Tutorial

Mini Portable Reader (MPR) Model HS 5900L F

My Weigh Ultraship Series User Manual

Quick start guide. ML17939/17959 Two-line corded telephone/ answering system with caller ID/call waiting

1. SAFETY INFORMATION

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

PA Series Precision Analytical Balances USER MANUAL

Evolution Digital HD Set-Top Box Important Safety Instructions

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

User Guide. Temperature and Humidity Datalogger. Model 42280

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

JVC Monitor Calibration 2 User's Guide

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

User's Guide. Integrating Sound Level Datalogger. Model Introduction

CONTIENTS. 1. SPECIFICATIONS (mm) CAUTIONS INSTALLATION INSTRUCTION

ELECTRONIC COUNTING SCALE. Operation Manual. l JCS- A SERIES

User Manual. Humidity-Temperature Chart Recorder. Model RH520

HP UPS R1500 Generation 3

Operating Instruction METTLER TOLEDO High-Capacity PM-Scales

Thermistor Thermometer MODEL NO

RACEAIR REMOTE PAGER SYSTEM

Video Cassette Player

Dehumidifier Users manual. For Models: DH45S DH65S

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

Setting Up the Cisco IP Phone

DMSG_0152_0112_V4 Mamas & Papas (Holdings) Ltd Dream Swing - 1 -

QUICK START GUIDE Bluetooth Cordless Hand Scanner (CHS)

Owner s Guide. ca6554

M O D U L E - 7 E Model CS-Caliprompter Operator s Manual

Connecting to an AC Power Outlet (Optional) General Description. a Connect the AC adapter to the printer. b Connect the AC power cord to the AC

User Guide for Cisco Unified IP Phones 7961G and 7941G

Instruction Manual Crane Scales PCE-HS Series

torbalcloud.com Instruction Manual: DRX-500s CLOUD

LinkRunner Pro TM. Network MultiMeter Quick Reference Guide. Welcome. What s in the box?

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

User checks and maintenance of laboratory balances

Digital Photo Frame User s Manual

Indoor Remote Controlled Power Points

USER GUIDE. Cisco Small Business Pro. SPA 500 Series IP Phones Models 504G, 508G, and 509G. Provided by

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

Model No. KX-TGP500. Model No. KX-TGP550

Using GIGABYTE Notebook for the First Time

Testing Your Laboratory Balance

LIFESTYLE V35/V25 HOME ENTERTAINMENT SYSTEMS T20/ T10 HOME THEATER SYSTEMS. Setup Guide Guía de instalación Guide d'installation

User manual DMX CONTROL 512. Table of contents

Computer Lane Monitor for Windows

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

INSTRUCTIONS FOR VOICE CONTROLLED TALKING ALARM CLOCK

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

GPSMAP 62 series quick start manual. For use with the GPSMAP 62, 62s, 62st, 62sc, and 62stc

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips

SA-9600 Surface Area Software Manual

Milwaukee USER MANUAL

Printed in China. Issue 4 AT&T 12/11. Message Guard is a registered trademark of Advanced American Telephones.

AT&T Small Business System Speakerphone with Intercom and Caller ID/Call Waiting 974

HomeSeer Technologies. HomeSeer Technologies LLC 35 Constitution Dr, Suite C Bedford NH,

SERVICE MANUAL VALOR Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

Config software for D2 systems USER S MANUAL

Parts List. Navigation

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

SwitchView 1000 Switch. Installer/User Guide

Model No. KX-TGP500. Model No. KX-TGP550

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

PA500II Enterprise Mobile Computer

BLOOD COLLECTION MIXER

Model SPA 303G Quick Start Guide

User's Guide. Pinless Moisture Meter. Model MO257

4-Channel Thermometer / Datalogger

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

Operating Instructions

snom 370 Quick Installation Kurzanleitung VoIP Business Phone snom technology AG All rights reserved. Version 1.

ANALYTICAL BALANCE OPERATION MANUAL. (FA/JA Series)

Use and Care Manual. Model CPA12KH AIR CONDITIONER

OCS-S High Resolution Digital Crane Scale

Monitoring Network DMN

Setting Up the ZigBee Ethernet Gateway

DAB Radio. Instruction Manual L55DAB10

Quick Guide. Precision Balances XS models

E E V R E - R S - O S L O A L R

How To Use A Ci 2001A/B (I2) With A Power Supply (I3)

BUSINESS. Elektronisches Türschloss. Installation and User Manual. Ingeniously safe. Ingeniously simple.

INDUSTRIAL INSTRUMENTATION

Transcription:

Calibration Guide PREPARATION Adventurer Pro Adventurer Pro balances have two calibration methods: Span and Linearity. Some models have Internal Calibration (InCal ) for Span calibration. Ensure that the scale is level, stable, and undisturbed during calibration. (Otherwise the process could fail.) Allow scale to warm up for five minutes after stabilizing to room temperature. Use suitable calibration masses (available from Ohaus). Exact weight value depends on model. Follow prompts for indicated values to use. (Weight values here are examples only.) Calibration may be locked out. To unlock it, use the Unlock menu. If the scale is set to Legal for Trade operation, a seal must be broken to unlock it. (See the Instruction Manual.) Note: To cancel calibration, press: INTERNAL CALIBRATION (No external weight needed.) 1 1 When calibration finishes, balance returns to currently selected mode. SPAN CALIBRATION (If InCal appears press No.) 1 1 (Acquiring zero value) 1 (Place weight on pan.) (If SPAN DONE flashes, remove mass from Pan.) (Press No to change.) Balance returns to weighing mode. Ohaus Corporation www.ohaus.com i Adventurer Pro Calibration Guide

Adventurer Pro Calibration Guide LINEARITY CALIBRATION: (If InCal appears press No.) 1 1 (Acquiring zero value) (Place weight on pan.) (Flashes while establishing weight value.) (Place weight on pan.) (Flashes while establishing weight value.) Remove weight from pan, and press: *80230* P/N 80230 Adventurer Pro Calibration Guide ii Ohaus Corporation www.ohaus.com

Calibration Guide CS Series Scales PREPARATION CS Scales can be calibrated as follows. Follow the prompts for calibration mass values. Ensure that the scale is level, stable, and undisturbed during calibration. (Otherwise the process could fail.) Allow scale to warm up for five minutes after stabilizing to room temperature. Use suitable calibration masses (available from Ohaus). Note: To cancel calibration, long-press: CALIBRATION 1 (Acquiring zero value) CAL -C- (Place weight on pan.) 1 C 200 -C- If calibration successful: PASS If calibration fails: CAL E If CAL E appears, turn the scale off and try again. Be sure to have the appropriate calibration weight. *802303* P/N 802303 Ohaus Corporation www.ohaus.com i CS Series Scales Calibration Guide

Calibration Guide Pioneer Balances PREPARATION Pioneer balances have two calibration methods: Span and Linearity. Some models have Internal Calibration (InCal ) for Span calibration. Ensure that the scale is level, stable, and undisturbed during calibration. (Otherwise the process could fail.) Allow scale to warm up for five minutes after stabilizing to room temperature. Use suitable calibration masses (available from Ohaus). Exact weight value depends on model. Follow prompts for indicated values to use. (Weight values here are examples only.) Calibration may be locked. To unlock it, use the Unlock menu. (See Instruction Manual.) Note: To cancel calibration, press: until scale turns off. INTERNAL CALIBRATION (No external weight needed.) (Two screens flash alternately.) (Flashes continuously while calibration proceeds.) Balance returns to weighing mode. SPAN CALIBRATION (If InCal appears press No.) 1 1 (Place weight on pan.) (Press No to choose alternate weight.) (Remove the mass from the Pan.) Balance returns to weighing mode. done Ohaus Corporation www.ohaus.com i Pioneer Balances Calibration Guide

Pioneer Balances Calibration Guide LINEARITY CALIBRATION: (not available on InCal models) (If InCal appears press No.) 1 (Place weight on pan.) (Remove the mass from the Pan.) (Acquiring zero value) (Place weight on Pan.) (Remove the mass from the Pan.) (Recalculating zero value) done Balance returns to weighing mode. *8022974* P/N 8022974 Pioneer Balances Calibration Guide ii Ohaus Corporation www.ohaus.com

Quick Start Guide PREPARATION FOR USE Release Shipping Lock on top of the balance Turn the pointer 90 counter-clockwise. Install the Platform Rectangular platform: Place diagonally on subplatform and rotate counter-clockwise until it locks. Round platform: Set straight down on subplatform. Scout Pro Balance Locked position Pointer Unlocked position Subplatform Draft Shield models: Position draft shield on top and rotate it until it faces forward. Connect Power Adapter jack Ensure voltage identification label matches local line voltage. If not, do not connect the unit. Contact Ohaus or your dealer. Battery Installation Install the Four AA batteries with polarity as shown in the battery compartment. Balances with leveling feet and bubble must be leveled before using. (Bubble is at rear, next to AC Adapter Input Jack.) SELECTING THE LOCATION: Place on a firm, steady surface with sufficient space. Avoid excessive air current, vibrations, heat sources, or rapid temperature changes. SAFETY PRECAUTIONS Before plugging in the balance, verify that local power supply matches voltage printed on power adapter. (Use only the adapter provided with the balance.) Disconnect the balance from the power supply when cleaning. Do not operate this product in hazardous or unstable environments. Do not drop loads on the pan. Use only approved accessories and peripherals, as available. Operate the product only under ambient conditions specified in the Instruction Manual. Service should be performed by authorized personnel only. Ohaus Corporation www.ohaus.com i Scout Pro Balance Quick Start Guide

Scout Pro Balance Quick Start Guide CONTROLS Battery charge indicator Symbols for weighing modes: G Specific Gravity N Newtons % Percent PC Pieces kg Kilograms, g grams dwt (not used) lb:oz (not used) ct (not used) t Totalize mode (or taels*) *Unit varies by model Stability indicator Button ON/ZERO Off PRINT Menu Functions Short Press (when off) Short Press:(when on) Long Press Extended Long Press Short press in Menu mode Short Press Press and Hold Short press in Menu mode Turns scale on. If balance is on, sets display to zero. Turns scale off. During power up, enters Menu mode. Accept setting on display. Sends print command to COM interface port. If Display Hold or Totalize mode is active, short press enters that mode. Scroll through Units. Release on desired unit. No (toggles through available settings) Locking the Menu The Lock Switch is used to lock out the menu mode, preventing unauthorized changes. To lock the menus, position the Lock Switch next to the tab on the bottom of the balance as shown. Locked Unlocked Scout Pro Balance Quick Start Guide ii Ohaus Corporation www.ohaus.com

Quick Start Guide Scout Pro Balance OPERATION Weighing Start with the balance on. 1 (Rezero the display) (Place sample on platform) (Example 0g) Taring a Container s Weight Taring zeros the container weight. With balance on, place an empty container on the platform. (Container weight) 1 (Container weight tared) (Place material in container) (Material and container removed) (0g sample) To remove tare, press ON/ZERO Off again. ADDITIONAL OPERATIONS Use the Units Menu to activate Parts Counting or Percent Weighing. (See back page.) To enable Display Hold, Totalize and Specific Gravity, use the Setup/Mode submenu. Parts Counting has two modes: (See Instruction Manual for more details.) Normal: balance determines quantity based on average weight of parts in original reference quantity. Enhanced: additional parts can be added to the platform ( the original number). The additional reference quantity produces a more accurate average part weight. Percent Weighing: place a reference weight on the balance, then view other loads as a percentage of the reference. The reference weight equals100%. Display-Hold mode captures and stores the highest stable value. When displayed, the stability indicator blinks. Note: Units cannot be changed when in Display-Hold mode. Totalize allows storage of a series of weight measurements. Totalize mode has been initiated when t and the current unit are displayed together. When totalized weight is shown, the t indicator blinks. Note: Units cannot be changed when in Totalize mode. The Specific Gravity mode allows calculating the specific gravity of a sample. (SPEC.GR mode must be turned ON before removing platform and installing hook.) Ohaus Corporation www.ohaus.com iii Scout Pro Balance Quick Start Guide

Scout Pro Balance Quick Start Guide MENU NAVIGATION There are four main menus in the balance:.c.a.l.,.s.e.t.u.p.,.u.n.i.t.s. and.e.n.d. (Start with the balance off and the Lock Switch off: see page ii). The sequence is shown below. 1 (Acquiring zero value) 1 1 1 (Weigh Mode) MENU STRUCTURE Accepting/Bypassing Menu Items Start with menu item displayed. 1 1 1 = YES Accept = NO (Short presses advance through menu) Cal Yes/No Setup Auto-Off Lin Cal -Yes/No Mode -Hold -Totalize -Specific Gravity Off End -Yes/No Units g kg oz lb PC -Count -Cnt.Enh Off % End -Yes/No End Yes/No *8023128* P/N 8022993 Scout Pro Balance Quick Start Guide iv Ohaus Corporation www.ohaus.com

Quick Start Guide YA Gold Series PREPARATION FOR USE The YA Gold Series scale comes fully assembled, except for battery installation. Use two high quality AAA batteries: insert in sequence, both in positive direction, as shown: AAA + + Allow at least 30-60 seconds warm-up time, for scale to stabilize before operation. PROPER ENVIRONMENT For dependable operation of this product, observe the following precautions: Avoid exposure to extreme heat or cold. Allow at least one hour stabilization after temperature change. Keep the scale in a clean environment. Dust, dirt, moisture, vibration, air currents, or proximity to other electronic equipment could adversely affect reliability and accuracy. Avoid shaking, dropping, or shocking the scale. Do not operate this product in unstable environments. Only operate the scale on a stable, vibration-free surface. Gently place items to be weighed on the platform. Rough treatment could damage the internal components. DISPLAY Tare mode (container weighing) Negative sign Symbols for: Grams, Ounces, Carats, Grains, Pieces (not used) Zero mode (standard weigh) Ohaus Corporation www.ohaus.com i YA Gold Series Pocket Scales Quick Start Guide

YA Gold Series Quick Start Guide OPERATION Place the scale on a horizontal flat surface. Press ON/OFF. Wait until 0.00 appears. Press MODE to switch weighing units: g-grams, oz-ounces, ct-carats or gngrains. Put the item to be weighed on the platform (eg,.1 carats). TARE: Turn on the scale as described above. Place a container on the platform (eg,.2 grams). Press TARE. The display shows 0.00 with TARE at left. Add material to the container (eg, 2 grams). Display shows weight of material not the container. When container and material are removed, display will show weight of container as negative value. ADDITIONAL OPERATIONS CHANGING UNITS OF MEASURE: Press Mode to toggle among four choices. Default: Grams g Press Mode once to choose Ounces oz Press Mode again to choose Carats ct Press Mode again to choose Grains gn *8023048* P/N 8023048 YA Gold Series Pocket Scales Quick Start Guide ii Ohaus Corporation www.ohaus.com