EMR-Shielding of an apartment / Amsterdam, The Netherlands. 1) Cell phone tower on a house nearby. 2) Application of HF shielding paint.



Similar documents
YSHIELD Shielding Paints 1/9

EMR Shielding of single level home from 3G mobile phone tower

HSF 54 HSF 74 HSF 92 NSF 34 Shielding HF X X X Shielding LF X X X X. Our ecological mineral paint for HF (+ LF) for LF Screening 1-layer

GUIDELINES SHIELDING INSTALLATIONS

Pure silicate paint for HF (+ LF) 37 db (99.98%) at 7.5 m²/l. 30 db (99.9%) at 7.5 m²/l Screening 2-layer. Building interior / exterior

Our new universal paint for HF + LF. Our longtime proven paint for LF Screening 1-layer

Users Manual FA106 / FA306 version 1.0. Field Analyzer. FA106 and FA306. Users Manual

Listen to Dr. Klinghardts EMR lecture:

The Salzburg Model: A Precautionary Strategy for Siting of Base Stations

College of Engineering, University of Kirkuk, -IRAQ

2010 Review. Health Effects and RF Radiation of Cell Phone Base Stations

Critical Product Information: VodeOX EMR Protection

Microwave Exposure from Mobile Phones and Base Stations in Sweden

COMPARING EXAMINATION OF ELECTROMAGNETIC FIELD LEVELS IN DOWNTOWN APARTMENT HOUSES WITH FLATS IN HOUSING ESTATES

EMR COMPLIANCE HOW TO ENSURE YOUR NATA ACCREDITED CONTRACTOR IS ABLE TO PROVIDE A NATA ENDORSED REPORT

Annex to the joint statement: Exposure of the general public to radiofrequency fields

SUBCHAPTER F. SMOKE ALARMS AND FIRE EXTINGUISHERS

Real-life Applications of ICNIRP Guidelines to Various Human EMF Exposure Issues

SOLAR POWER. Information Book

High electricity costs and cell phone antennas: Is there a connection?

PLOT 21: Cell phone measurement setup.

ELECTRIC POWER FREQUENCY (60 Hz) ELECTRIC AND MAGNETIC FIELDS (EMFs)

within body bioelectricity is a biofield. It is due to concentration gradient generated across membrane of the cell.

sources in our environment i.e. Natural and man-made. The sun, earth and ionosphere are the natural source.

SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES

HOW GREEN IS YOUR CORDLESS PHONE? RF RADIATION REVIEW

CASE STUDY. Sarakasi Theatre Nairobi, Kenya Room Acoustical Measurements and Modelling. Africa Room Acoustics DIRAC and ODEON

Budapest Students / 20 Frequently Asked Questions benedek.palvolgyi@kategora.com Tel:

SMOKE ALARMS CLASS 1A BUILDINGS

Ringing at the Door. Boiling an egg. Moving by car. Flows of solar energy. There is no energy crisis. How to boil an egg?

EAST LONDON GUIDANCE ON HMO STANDARDS (3)

CENTRAL POLLUTION CONTROL BOARD AWARENESS NOTE ON MOBILE TOWER RADIATION & ITS IMPACTS ON ENVIRONMENT

How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless)

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz

Indoor Environment Electromagnetic Radiation

EMR Exposure Limits & Assessment Methods for Mobile Phone Communications. Lindsay Martin Manager, Non-Ionising Radiation Section

12. INDOOR INSTALLATION

How To Understand The Kv3Um Electro Magnetic Radiation

3 Radio Waves and Human Body 8 Specific Absorption Rate (SAR)... 8 SAR value of a mobile handset... 8 Radiation level by a mobile tower...

Acoustic expectations, health effects, and design techniques in the urban environment

Mobile Phone Base-Station Audit

EAST LONDON HMO GUIDANCE (4)

First Nation Mold Remediation Case Study Tsartlip First Nation

EXPOSURE INDICES IN RF EPIDEMIOLOGY

Smoke Detector/Carbon Monoxide Detector Inspections

Irish Water meters and AMR technology

DOMESTIC SMOKE ALARMS

MEASUREMENT AND ANALYSIS OF RF EME LEVELS FROM MOBILE TELEPHONE BASE STATIONS LOCATED AT LEICHHARDT, NSW

Title: Attic Keyword: Structure Description: roof framing rafters and decking File Name: P

Monceau Elegance. Quick facts 8eme ardt, Paris, France metro: Miromesnil (Lines 9 & 13) size: 156m2 or 1679 sq ft. sleeps: up to 4

What are radio signals?

PROGRAM PROSPECTUS Electromagnetic Radiation Specialist EMRS Certification Program

Mobile Telecommunications in Kempten West Blood levels alarmingly altered

Heating and Ventilation

Prudent Avoidance Policy on Siting Telecommunication Towers and Antennas

720r Addendum: Siting the 720r

EXHIBITION DISPLAY RULES

ELECTROMAGNETIC FIELDS AND PUBLIC HEALTH HEALTH AND SAFETY GUIDELINES #1

Shetton Barns Mansell Lacy, Herefordshire HR4 7HP

Affordability Analysis of 801 South Street Tower B. Revised: 21 November Ariel Salinas

When we first considered the construction of a unique residential project, we searched the city for the best possible location.

Advanced Measurements of Microwave Oven Leakage

UNDERSTANDING RADIO FREQUENCY AND BC HYDRO S SMART METERS

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

Keywords Mobile Tower Radiations, Electromagnetic Radiations, Signal Strength, Mobile Phone

Ramon 2.2 Radon-Monitor

Complete Solar Photovoltaics Steven Magee. Health and Safety

The BRAG Antenna Ranking of Schools Grades School Children s Exposure to Cell Antennas in U.S. State Capitols & Washington, D.C.

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

The Association of Electrical and Medical Imaging Equipment Manufacturers Arc Fault Circuit Interrupter

MODERATE INCOME HOUSING UNIT PROGRAM PRICE & RENT SUMMARY FOR LOW INCOME ALTERNATIVE January 1 through June 30, 2016*

Renovation and upgrading of Waterlandplein post-war housing blocks, Amsterdam

healthy homes assessment

How To Decide If A Cell Phone Antennae Can Be Installed On A Condominium Roof

Home Build Solar System is the website where you can get the information you need to build your own solar system.

Homeowners Audio (Part #1) Background on the Homeowners Policy, Underwriting Process and Eligibility

Are photoelectric smoke alarms better than ionization smoke alarms for adjacent to kitchen installations, to minimize nuisance alarms?

GENERAL WIRING RULES FOR HOUSES

HF-RADIATION LEVELS OF GSM CELLULAR PHONE TOWERS IN RESIDENTIAL AREAS

Impact of Reflectors on Solar Energy Systems

A step forward. MyGait. The functional electrical stimulation system for drop foot. Information for users

Noise Monitoring Software, version 7.0 Types 7802 and 7840

Mobile use, radio signals and health

Assessment of SAR in a human exposed to GSM electromagnetic fields

OHIO BOARD OF BUILDING STANDARDS. Smoke Alarms and Fire Safety

RF Exposure Evaluation Report

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Fixed Wireless Fact Sheet

120V & 208V ELECTRICAL SERVICE ORDER FORM

Churches and Schools Development Standards

Human Exposure to Radiofrequency Electromagnetic Radiation

Measuring electric and magnetic fields

TOWN OF OHIO BUILDING PERMIT APPLICATION

Millennium Product Inc. Model: Cell Shield / Zorb

Arch Insurance Group Wrap-Up Application For Insurance

Hybrid positioning and CellLocate TM

End Fed Antenna. Operating Manual. version 1.1

Power Rating Simulation of the new QNS connector generation

MRET-Shield Synopsis of Scientific Research Updated on June 1, 2007

CERTIFICATE OF COMPLIANCE

Transcription:

EMR-Protection Shielding Paints EMR-Shielding of an apartment / Amsterdam, The Netherlands Shielding of an apartment at the airport Amsterdam in the Netherlands with shielding paint HSF54. Scope of project: Shielding against microwave radiation from a cell phone tower. Project carried out by customer. 1) Cell phone tower on a house nearby. 2) Application of HF shielding paint. 3) Painting of the ceiling in progress. 4) Radiation levels / power flux density: Before shielding: 150 μw/m²; After shielding: 0.08 μw/m² Testimonial The first day I moved in my apartment, I found that I could not sleep. I woke up at 3:00 and 4:00 am. I realized there might be something wrong with my apartment. When I checked around my apartment, I found out there is a cell phone tower just 50 meter away from me. I checked on internet, I found paint. The professional assistance of them gave me the confidence to try out their product. They provide the radio frequency meter to measure the difference before and after applying the paint. The result is amazing. The reading of the radiation decreases from 150 μw/m² (= 0.15 mw/m², see left picture) to 0.08 μw/m². Now I can sleep very well. Thanks to the product of. C. L., electronics engineer, The Netzerlands / Taiwan

EMR-Protection Shielding Paints EMR-Shielding of BAUFRITZ - houses / Erkheim, Germany EMR protection has partnered with BAUFRITZ company in Bavaria for the development of EMR protection paints which are based on renewable resources. R&D developed a unique shielding paint using only natural binding agents. HSF71 BAUFRITZ shielding paint is currently used in BAUFRITZ houses with cell towers in the vicinity, to provide maximum protection for homeowners even in areas with high microwave exposure levels. See www.baufritz.de and www.baufritz.co.uk. Salzburg Federal Clinics (SALK), Medical Research / Salzburg, Austria shielding paints were used in a medical research project carried out at the SALZBURG Federal Clinics (SALK) in Austria. s HSF54 shielding paint was used in this project for the shielding of a predefined area, to make sure that all research subjects were exposed to equal levels of microwave radiation (from a nearby cellphone tower) during the testing periods. The interdisciplinary research projects was performed by Univ.-Prof. Dr. Gerhard W. Hacker and his team, IGGMB - Research Institute for Frontier Questions of Medicine and Biotechnology, Salzburg Federal Clinics, www.med-grenzfragen.at

EMR-Protection Shielding Paints EMR-Shielding of a family home / Bruck a.d. Mur, Austria Shielding of a family home in Austria with shielding paint HSF53. Scope of project: Shielding against microwave radiation from a cell phone tower. Project carried out by customer. 1) Application of shielding paint. 2) Shielding paint applied on both sides. 3) Grounding of the shielding paint. 4) Application of the top coat. 6) Perfectly white again. 6) Point of measurement marked; power flux density in μw/m²; before shielding: after shielding:

EMR-Protection Shielding Paints Shielding of condominiums, block of flats / Budapest, Hungary Shielding of condominiums / owner-occupied flats in Hungary with shielding paints NSF34 / HSF54. Scope of project: Shielding of low-frequency AC electric fields for all household electrical installation / wiring; as an option shielding of high-frequency electric radiation was also offered. Project was carried out by Quadrat Kft company, Hungary. 1) View of typical apartment building. 2) Plan of individual apartments. 3) Shielding of a power distribution room, 4) Shielding of all household installation / wiring. adjacent to a childrens bedroom. 5) Finished appartment, grounding in bottom left.

EMR-Protection Shielding Paints EMR-Shielding of a ground floor apartment / Vienna, Austria Shielding of a ground floor apartment in Austria with shielding paint HSF54. Scope of project: Shielding against a combined GSM / UMTS cell phone tower on the neighboring house. Project carried out by customer. 1) The cell phone tower on neighboring house. 2) Painting of the living room in progress. 3) Different view. 4) The used shielding paint HSF54. 5) The room, white again and newly furnished. 6) Radiation levels / power flux density: Before shielding: 798 μw/m²; After shielding: 0.47 μw/m²

EMR-Protection Shielding Paints EMR-Shielding of office and family homes / Melbourne, Australia 1) EMR-Shielding of an office in Australia. The right picture shows the grounding installation (before application of the shielding paint) using s ground connection set ES and ground strap EB. 2) EMR-Shielding of a family home in Australia with shielding paint HSF54 applied to the wooden siding. Scope of project: Shielding against the cell phone tower in the church steeple (left picture). 3) EMR-Shielding of a family home in Australia using shielding paint HSF54. Radiation levels / power flux density: Before shielding: 604 μw/m²; After shielding: 0.26 μw/m²

EMR-Protection Shielding Paints EMR-Shielding of sleeping area / Eferding, Austria Shielding of a sleeping area and of a children s room in Austria with shielding paint HSF54. Scope of project: Shielding against microwave radiation from a nearby cell phone tower. Project carried out by Grabmann Co., Austria, http://www.elektrosmog-messung.at 1) Before HF-shielding: 8.2 μw/m². 2) Application of HF shielding paint. 3) After HF shielding: 0.2 μw/m². 4) White again with two layers of latex paint. 5) Shielding effectiveness (μw/m²). Testimonial On behalf of my family I want to inform you, that the application of HF shielding paint, and the use of shielding fabric as curtains, has much improved the situation in our bedrooms for both ourselves and for our children. Our little daughter sleeps through the nights now, what was unknown before, and she is also more even-tempered during the day. My wife and I feel that the overall quality of our lives has significantly improved. We think that - given the circumstances (cell phone tower in close vicinity) - we have done the best for us and for the health of our children. Thank you much for your help Dr. J. and M. Z., name and address withheld

EMR-Protection Shielding Paints EMR-Shielding of a duplex, semi-detached house / Dorfen, Germany Shielding of a semi-detached house im Germany with shielding paint HSF54. Scope of project: Shielding against a combined GSM / UMTS mobile phone tower, which was erected 100 meters from the family home. Project carried out by customer. 1) An opponent to cell phones is painting it black. 2) The paint is easy to handle... 3)... says the homeowner, a professional painter. 4) The duplex is shielded. 5) The family home is white again. 6) Radiation levels / power flux density: 2648 μw/m² - Before shielding - 650 μw/m² 10.2 μw/m² - After shielding - 4.43 μw/m²

EMR-Protection Shielding Paints EMR-Shielding of a loft, attic flat / Amstetten, Austria Shielding of a loft in Austria with shielding paint HSF54. Scope of project: Shielding against microwave radiation from a nearby cell phone tower and against low-frequency fields from electrical installation. Project carried out by Grabmann Co., Austria, http://www.elektrosmog-messung.at 1) Cell phone tower on a house nearby. 2) Before HF-shielding: 158.7 μw/m². 3) Application of HF shielding paint. 4) ) After HF shielding: 4.2 μw/m². 5) Shielding effectiveness (μw/m²). 6) Graph shows: perfect shielding against LF-electric fields.