Path-ID Multiplex One-Step RT-PCR Kit



Similar documents
One Shot TOP10 Competent Cells

TaqMan Fast Advanced Master Mix. Protocol

High-Capacity cdna Reverse Transcription Kits For 200 and 1000 Reactions

NIH Mammalian Gene Collection (MGC)

Protocol. Introduction to TaqMan and SYBR Green Chemistries for Real-Time PCR

MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C

Megaplex Pools For microrna Expression Analysis

Mir-X mirna First-Strand Synthesis Kit User Manual

Absolute Quantification Getting Started Guide

CompleteⅡ 1st strand cdna Synthesis Kit

Thermo Scientific DyNAmo cdna Synthesis Kit for qrt-pcr Technical Manual

Real-time quantitative RT -PCR (Taqman)

User Manual. CelluLyser Lysis and cdna Synthesis Kit. Version 1.4 Oct 2012 From cells to cdna in one tube

Mir-X mirna First-Strand Synthesis and SYBR qrt-pcr

Stratagene QPCR Mouse Reference Total RNA

Real-time PCR: Understanding C t

OpenArray Sample Tracker Software

Fluorescein Isothiocyanate (FITC)- conjugated Antibodies

Essentials of Real Time PCR. About Sequence Detection Chemistries

Fast SYBR Green Master Mix. Protocol

ab Hi-Fi cdna Synthesis Kit

Genomic DNA Clean & Concentrator Catalog Nos. D4010 & D4011

RealLine HCV PCR Qualitative - Uni-Format

RT-PCR: Two-Step Protocol

PyroPhage 3173 DNA Polymerase, Exonuclease Minus (Exo-)

Applied Biosystems KRAS Mutation Analysis Reagents. Protocol

Highly specific and sensitive quantitation

SYBR Green Realtime PCR Master Mix -Plus-

Relative Quantification Applied Biosystems 7300/7500 Real Time PCR System

HBV Quantitative Real Time PCR Kit

Absolute Quantitation Using Standard Curve Getting Started Guide

RealStar HBV PCR Kit /2012

Absolute Quantitation Using Standard Curve Getting Started Guide

Power SYBR Green PCR Master Mix and Power SYBR Green RT-PCR Reagents Kit

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

Dengue Virus subtypes 1,2 3 and 4. genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... 3 Untranslated Region (3 UTR) 150 tests

Standard Mixture. TOF/TOF Calibration Mixture. Calibration Mixture 1 (Cal Mix 1, 1:10) Calibration Mixture 1 (Cal Mix 1, 1:100)

AffinityScript QPCR cdna Synthesis Kit

First Strand cdna Synthesis

RevertAid Premium First Strand cdna Synthesis Kit

TaqMan MicroRNA Assays

SYBR Green PCR Master Mix and SYBR Green RT-PCR Reagents Kit

Human Herpes Virus 1 (Herpes simplex type 1) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

Epstein Barr Virus (Human Herpes virus 4) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

Genomic DNA Extraction Kit INSTRUCTION MANUAL

Table of Contents. I. Description II. Kit Components III. Storage IV. 1st Strand cdna Synthesis Reaction... 3

TaqMan Salmonella Enteritidis Detection Kit. Egg and Environmental Testing Protocol

RIBOPROTECT. RNase Inhibitor RT33-020, RT33-100

Taq98 Hot Start 2X Master Mix

Factors Influencing Multiplex Real-Time PCR

ExpressArt Bacterial H-TR cdna synthesis kit. With extreme selectivity against rrnas

TaqMan Mutation Detection Assay

TaqMan Copy Number Assays. Protocol

Human Herpes Virus 4 (Epstein Barr)

Applied Biosystems 3500/3500xL Genetic Analyzer

Reverse Transcription System

For safety information, see the ABI PRISM 310 Genetic Analyzer User s Manual (PN or ).

mircute mirna qpcr Detection Kit (SYBR Green)

UltraClean PCR Clean-Up Kit

Isolation of Total RNA from Cultured Cells

All-in-One First-Strand cdna Synthesis Kit

360 Master Mix. , and a supplementary 360 GC Enhancer.

UltraClean Soil DNA Isolation Kit

PCR Instruments and Consumables

FOR REFERENCE PURPOSES

PrimeSTAR HS DNA Polymerase

Epstein Barr Virus (Human Herpes virus 4) nonglycosylated membrane protein (BNRF1) gene. genesig Advanced Kit. DNA testing

PicoMaxx High Fidelity PCR System

Speed Matters - Fast ways from template to result

BacReady TM Multiplex PCR System

Applied Biosystems 7500/7500 Fast Real-Time PCR Systems. SUBJECT: Memory Upgrade Requirements for 7500 Software v2.0

Platinum Multiplex PCR Master Mix

Application Guide... 2

Real-Time PCR Vs. Traditional PCR

Quantification of Mycobacterium Tuberculosis. 150 tests

Hepatitis B Virus. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere... Core Protein Region. 150 tests.

RT rxns. RT rxns TRANSCRIPTME Enzyme Mix (1) 40 µl 2 x 50 µl 5 x 40 µl

Real-Time Quantitative PCR Instruments and Consumables

MMLV High Performance Reverse Transcriptase

Agilent High Sensitivity DNA Kit Guide

DyNAmo cdna Synthesis Kit for qrt-pcr

All-in-One mirna qrt-pcr Reagent Kits For quantitative detection of mature mirna

Introduction To Real Time Quantitative PCR (qpcr)

BigDye Terminator v3.1 Cycle Sequencing Kit. Protocol. DRAFT August 27, :32 pm, A_v3.1Title.fm

Quantification of Hepatitis B Virus. Core Protein Region. 150 tests

STA DARD OPERATI G PROCEDURE FOR THE DETECTIO OF AFRICA SWI E FEVER VIRUS (ASFV) BY REAL-TIME POLYMERASE CHAI REACTIO (PCR)

Arcturus PicoPure RNA Isolation Kit. User Guide

Reconstituting and Diluting Primers and TaqMan Probes

TIANquick Mini Purification Kit

Relative Quantitation Using Comparative C T Getting Started Guide

QuantiNova Reverse Transcription Kit Handbook

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

MagExtractor -Genome-

Genomic DNA detection assay

FastLine cell cdna Kit

EZ-PAGE Electrophoresis System USER MANUAL

Transcription:

USER GUIDE Path-ID Multiplex One-Step RT-PCR Kit TaqMan probe-based multiplex one-step real-time RT-PCR detection of RNA targets Catalog Numbers 4428206, 4428207, 4440022 Publication Part Number 4440907 Rev. C Revision Date May 2012 For Research Use Only. Not for human or animal therapeutic or diagnostic use.

For Research Use Only. Not for human or animal therapeutic or diagnostic use. COPYRIGHT The information in this guide is subject to change without notice. DISCLAIMERS LIFE TECHNOLOGIES CORPORATION AND/OR ITS AFFILIATE(S) DISCLAIM ALL WARRANTIES WITH RESPECT TO THIS DOCUMENT, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT. TO THE EXTENT ALLOWED BY LAW, IN NO EVENT SHALL LIFE TECHNOLOGIES AND/OR ITS AFFILIATE(S) BE LIABLE, WHETHER IN CONTRACT, TORT, WARRANTY, OR UNDER ANY STATUTE OR ON ANY OTHER BASIS FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING FROM THIS DOCUMENT, INCLUDING BUT NOT LIMITED TO THE USE THEREOF. TRADEMARKS The trademarks mentioned herein are the property of Life Technologies Corporation and/or their affiliates or their respective owners. TaqMan and AmpliTaq Gold are registered trademarks of Roche Molecular Systems, Inc., used under permission and license. Limited Use Label License: Research Use Only The purchase of this product conveys to the purchaser the limited, non-transferable right to use the product only to perform internal research for the sole benefit of the purchaser. No right to resell this product or any of its components is conveyed expressly, by implication, or by estoppel. This product is for internal research purposes only and is not for use in commercial applications of any kind, including, without limitation, quality control and commercial services such as reporting the results of purchaser s activities for a fee or other form of consideration. For information on obtaining additional rights, please contact outlicensing@lifetech.com. 2012, Life Technologies Corporation. All rights reserved.

Contents Chapter Path-ID Multiplex One-Step RT-PCR Kit..................... 5 Product information........................................................ 5 Materials and equipment required............................................ 7 Procedure............................................................... 9 Troubleshooting.......................................................... 10 Appendix Safety................................................ 11 Chemical safety.......................................................... 12 Chemical alerts....................................................... 12 Documentation and Support............................... 13 Obtaining SDSs.......................................................... 13 Obtaining Certificates of Analysis............................................ 13 Obtaining support........................................................ 13 Limited Product Warranty.................................................. 13 3

Contents 4

Path-ID Multiplex One-Step RT-PCR Kit Protocol Product information IMPORTANT! Before using this product, read and understand the information in the Safety appendix in this document. Purpose of the product The Path-ID Multiplex One-Step RT-PCR Kit is designed for multiplex, quantitative, reverse transcription PCR (qrt-pcr). It is optimized for the amplification of up to four targets simultaneously using your RNA samples and TaqMan primer/probe sets. Reactions are run using a single-tube, one-step procedure to reverse-transcribe the RNA and amplify your targets. The kit contains a Multiplex Enzyme Mix with ArrayScript reverse transcriptase and AmpliTaq Gold DNA Polymerase, and a buffer mix. Reactions are run and detected in a thermal cycler capable of real-time detection of amplification products to yield quantitative data. Figure 1 shows amplification plots from reactions that included four targets using the Path-ID Multiplex One-Step RT-PCR Kit. Three of the targets in the experiment were held constant, but the fourth was serially diluted to show the dynamic range of multiplex target detection with the kit. Figure 1 Four-plex amplification of control RNAs using the Path-ID Multiplex One-Step RT-PCR Kit 5

Path-ID Multiplex One-Step RT-PCR Kit Product information Xeno RNA Control and control RNAs for virus B, virus E, and virus N were amplified in a multiplex RT-PCR using the Path-ID Multiplex One-Step RT-PCR Kit on an Applied Biosystems 7500 Real-Time PCR System. This experiment included a sample set with fixed amounts of three of the targets and a serial dilution series of the virus N control RNA. Note that virus N was detected even in four-plex reactions containing only 400 copies (~33 C T ). Kit contents Component Cat. no. 4428206 100 reactions Cat. no. 4428207 500 reactions Cat. no. 4440022 1000 reactions Multiplex RT-PCR Buffer 1.375 ml 7 ml 14 ml Multiplex Enzyme Mix 280 L 1.4 ml 2 1.4 ml Nuclease-free Water 1.75 ml 25 ml 25 ml Storage Store the kit at 10 C to 30 C in a non-frost-free freezer. You can store the Nuclease-free Water at 10 C to 30 C, 2 C to 8 C, or at room temperature. 6

Path-ID Multiplex One-Step RT-PCR Kit Materials and equipment required Materials and equipment required RNA sample(s) It is important to use pure RNA that is free of RT-PCR inhibitors in the procedure. We recommend the MagMAX RNA Isolation Kit appropriate for your sample type; go to www.lifetechnologies.com, then search for MagMAX. When isolating viral RNA from cell-free sample sources such as serum, use MagMAX Viral RNA Isolation Kits, which include carrier RNA to maximize viral RNA recovery. PCR primer/taqman probe mixture You can use any licensed PCR primer/taqman probe mixture compatible with your real-time PCR instrument and designed for one-step RT-PCR with the kit. Optimization of PCR primer and probe concentrations is critical for multiplex reactions. In reactions with targets of different abundance, it is necessary to limit the PCR primer concentrations of highly abundant targets so that less abundant targets can effectively compete for the amplification reagents. The concentration of primers and probes may require optimization, but the concentrations shown in the following table typically work well. Note: The Reverse Transcriptase enzyme contained in this kit is produced using an E. coli expression vector containing a proprietary version of the MMLV pol gene (GenBank accession no. J02255) expressed from pet-24(+). It is possible that a minimal amount of the expression vector could be carried over into the final mastermix formulation. If you are targeting MMLV, a related virus, or any of the plasmid sequence, we recommend designing primer sequences not contained in the expression vector. Component Final concentration in the reaction 25 primer/probe mix Forward PCR primer 400 nm 10 M Reverse PCR primer 400 nm 10 M TaqMan probe 120 nm 3 M Use 1 µl per 25-µL RT-PCR of a PCR primer/taqman probe mixture prepared at these concentrations. Real-time PCR systems and accessories The Path-ID Multiplex One-Step RT-PCR Kit is compatible with the following Applied systems: 7500 Real-Time PCR System 7500 Fast Real-Time PCR System 7900HT Real-Time PCR System (96-well and 384-well sample block) 7900HT Fast Real-Time PCR System (96-well and 384-well sample block) StepOne Real-Time PCR System StepOnePlus Real-Time PCR System You need the following accessories: 7

Path-ID Multiplex One-Step RT-PCR Kit Materials and equipment required Reaction plates and covers appropriate for your real-time PCR system. See the Plastic Consumables Compatibility Chart: go to www.lifetechnologies.com, then select Products and Services Real-Time PCR PCR tubes, Plates & Accessories. Nuclease-free pipettes and tips. Reagent reservoirs or tubes for preparing the master mixes. 8

Path-ID Multiplex One-Step RT-PCR Kit Procedure Procedure For the following hazards, see the complete safety alert descriptions in Chemical safety on page 12. CAUTION! CHEMICAL HAZARD. Multiplex RT-PCR Buffer. CAUTION! CHEMICAL HAZARD. Multiplex Enzyme Mix. Program the real-time PCR instrument Use the thermal cycling conditions shown in the following table. ROX passive reference dye is included in the Multiplex RT-PCR Buffer. For real-time PCR instruments capable of Fast thermal cycling, set the mode to Standard. The suggested reaction volume is 25 L. Step Stage Reps Temp Time Reverse transcription 1 1 48 C 10 min RT inactivation/ 2 1 95 C 10 min initial denaturation Amplification 3 40 95 C 15 sec 60 C 45 sec For long targets, the extension time may need to be >45 seconds. Prepare the reactions 1. Prepare the RT-PCR master mix(es) on ice (see the required volumes in the following table): Prepare 5 10% extra master mix. Include duplicate no template controls (NTCs or negative controls) using Nuclease-free Water in place of sample. 2. Add the RT-PCR master mix to a reaction plate or tubes. 3. Add sample to each reaction. Component Volume ( L) RT-PCR Multiplex RT-PCR Buffer 12.5 master mix Forward and reverse PCR primers TaqMan probes Multiplex Enzyme Mix 2.5 RNA sample (Nuclease-free Water for NTCs) Total volume per reaction 25.0 Perform thermal cycling and analyze the data Follow the instructions for your real-time PCR instrument for multiplex reactions. 9

Path-ID Multiplex One-Step RT-PCR Kit Troubleshooting Troubleshooting Observation Possible Cause Solution No signal from samples expected to be positive Low signal from samples expected to be positive Signal detected in no template control (NTC) RNA sample contains PCR inhibitors RNA sample contains low level of PCR inhibitors Use less starting sample as input for your RNA isolation procedure. Increase the number or stringency of washes during RNA isolation. Use less RNA sample in the qrt-pcr. See the solution to Low signal from samples expected to be positive. Samples containing minimal amounts of inhibitors may yield successful qrt-pcr reactions if less RNA sample (and therefore less inhibitor) is added to the reaction. For example: Reduce the sample volume to 1 to 2 L, then add Nuclease-free Water to bring the reaction to the proper volume. -Or- Dilute the RNA sample 1:10 using the solution used to elute the nucleic acid at the end of the nucleic acid isolation procedure, then use the diluted RNA in the qrt-pcr reaction. -Or- Dilute the RNA sample 1:10 using 10 mm Tris-HCl ph 8, 0.1 mm EDTA, then use the diluted RNA in the qrt-pcr reaction. PCR contamination Repeat the qrt-pcr reaction with fresh reagents and decontaminated pipettors. Set up and run the qrt-pcr reaction in an area that is isolated from areas used for nucleic acid isolation and PCR product analysis. Note: The Reverse Transcriptase enzyme contained in this kit is produced using an E. coli expression vector containing a proprietary version of the MMLV pol gene (GenBank accession no. J02255) expressed from pet- 24(+). It is possible that a minimal amount of the expression vector could be carried over into the final mastermix formulation. If you are targeting MMLV, a related virus, or any of the plasmid sequence, we recommend designing primer sequences not contained in the expression vector. 10

APPENDIX Safety WARNING! GENERAL SAFETY. Using this product in a manner not specified in the user documentation may result in personal injury or damage to the instrument or device. Ensure that anyone using this product has received instructions in general safety practices for laboratories and the safety information provided in this document. Before using an instrument or device, read and understand the safety information provided in the user documentation provided by the manufacturer of the instrument or device. Before handling chemicals, read and understand all applicable Safety Data Sheets (SDSs) and use appropriate personal protective equipment (gloves, gowns, eye protection, etc). To obtain SDSs, see the Documentation and Support section in this document. 11

Appendix Safety Chemical safety Chemical safety WARNING! GENERAL CHEMICAL HANDLING. To minimize hazards, ensure laboratory personnel read and practice the general safety guidelines for chemical usage, storage, and waste provided below, and consult the relevant SDS for specific precautions and instructions: Read and understand the Safety Data Sheets (SDSs) provided by the chemical manufacturer before you store, handle, or work with any chemicals or hazardous materials. To obtain SDSs, see the Documentation and Support section in this document. Minimize contact with chemicals. Wear appropriate personal protective equipment when handling chemicals (for example, safety glasses, gloves, or protective clothing). Minimize the inhalation of chemicals. Do not leave chemical containers open. Use only with adequate ventilation (for example, fume hood). Check regularly for chemical leaks or spills. If a leak or spill occurs, follow the manufacturer's cleanup procedures as recommended in the SDS. Handle chemical wastes in a fume hood. Ensure use of primary and secondary waste containers. (A primary waste container holds the immediate waste. A secondary container contains spills or leaks from the primary container. Both containers must be compatible with the waste material and meet federal, state, and local requirements for container storage.) After emptying a waste container, seal it with the cap provided. Characterize (by analysis if necessary) the waste generated by the particular applications, reagents, and substrates used in your laboratory. Ensure that the waste is stored, transferred, transported, and disposed of according to all local, state/provincial, and/or national regulations. IMPORTANT! Radioactive or biohazardous materials may require special handling, and disposal limitations may apply Chemical alerts Specific chemical alerts CAUTION! CHEMICAL HAZARD. Multiplex RT-PCR Buffer may cause eye, skin, and respiratory tract irritation. Read the MSDS, and follow the handling instructions. Wear appropriate protective eyewear, clothing, and gloves. CAUTION! CHEMICAL HAZARD. Multiplex Enzyme Mix may cause eye, skin, and respiratory tract irritation. Read the MSDS, and follow the handling instructions. Wear appropriate protective eyewear, clothing, and gloves. 12

Documentation and Support Obtaining SDSs Safety Data Sheets (SDSs) are available from www.lifetechnologies.com/support Note: For the SDSs of chemicals not distributed by Life Technologies Corporation, contact the chemical manufacturer. Obtaining Certificates of Analysis The Certificate of Analysis provides detailed quality control and product qualification information for each product. Certificates of Analysis are available on our website. Go to www.lifetechnologies.com/support and search for the Certificate of Analysis by product lot number, which is printed on the box. Obtaining support For the latest services and support information for all locations, go to: www.lifetechnologies.com/support At the website, you can: Access worldwide telephone and fax numbers to contact Technical Support and Sales facilities Search through frequently asked questions (FAQs) Submit a question directly to Technical Support Search for user documents, SDSs, vector maps and sequences, application notes, formulations, handbooks, certificates of analysis, citations, and other product support documents Obtain information about customer training Download software updates and patches Limited Product Warranty Life Technologies Corporation and/or its affiliate(s) warrant their products as set forth in the Life Technologies' General Terms and Conditions of Sale found on Life Technologies Corporations website at www.lifetechnologies.com/termsandconditions. If you have any questions, please contact Life Technologies Corporation at www.lifetechnologies.com/ support. 13

Documentation and Support Limited Product Warranty 14

Headquarters 5791 Van Allen Way Carlsbad, CA 92008 USA Phone +1 760 603 7200 Toll Free in USA 800 955 6288 For support visit www.lifetechnologies.com/support or email techsupport@lifetech.com www.lifetechnologies.com