IVIS IVIS - Indoor Video Insertion System



Similar documents
DVIS/DVISm Digital Video Insertion System & Mini Digital Video Insertion System FIRMWARE UPGRADE INSTRUCTIONS

SMAC SM Status Monitoring and Control Quality of Service (QoS) Diplex Switch Test Gear. Installation & Operation Manual

How To Set Up & Manage an IPTV System WHITE PAPER

IsumaTV. Media Player Setup Manual COOP Cable System. Media Player

MISE - STEREO ENCODER

IMPORTANT SAFETY INSTRUCTIONS

D3.1 / CCAP Compliant. 1.2 GHz. QMP1000 Forward RF Amplifier. Installation & Operation Manual

Digital Satellite Receiver

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices

Technicolor ATSC-8. User s Guide Technicolor. All Rights reserved

Evolution Digital HD Set-Top Box Important Safety Instructions

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

DTA100. Digital Transport Adapter. Quick Start Guide. Downloaded from manuals search engine

Hear The Future...Now! SIEM-2T/SIEM-2R

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

DSA800 Series Spectrum Analyzer

AVR 158. Audio/video receiver. Quick-Start Guide ENGLISH

DIGITAL CABLE TV RECEIVER OPERATION MANUAL DVB-C8080AL DIGITAL CABLE RECEIVER DEAR CONSUMER

CX380X Advanced Spectrum and Burst QAM Analyzer

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

"FP", "FR", "FQ" Series Bandpass Filters

Doorbell Intercom Security System

Broadband Reference Guide

INPUT SWITCH OPTIONS:

INSTRUCTION MANUAL MODEL PCD-88

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

RMS-2FS Stereo FM Transmitter Monitoring System

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

Model 8710 x Home Communications Terminal

MCR1900 Media Converter 19-Slot Chassis

IsumaTV connexion to COOP cable system Set up manual

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

CINEMATE 1 SR DIGITAL HOME THEATER SPEAKER SYSTEM. Operating Guide Guía del usuario Guide d utilisation

User Manual Wohler Technologies Inc. ALL rights reserved ECO-2668 (10/13/04)

Tone Hammer 500. Owners Manual. Manual Version 1.0

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

ELEMENTS OF CABLE TELEVISION

How To Connect A Tv Box To A Tv Set Top Box With A Tv Antenna From Ikusi

HP UPS R1500 Generation 3

Application Note: Extending a TSP s Analog Capabilities Using an Access Bank I

Cisco D9865 Satellite Receiver

USER GUIDE MANUAL DCT700. One-way Application

LOXONE 12 Channel Amplifier

MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.

GSM-EXT Cable Assembly Installation Guide

Home Gateway. User s Installation Guide. In This Guide

OWNERS MANUAL CONTENTS: Introduction.. 2. Definitions.. 2. Smartwire.. 4. Computing Network 7. Working diagram. 8. Television Antennas 9

TS2 VRack. User and Installation Manual

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)

HTT 101. HDMI/YPbPr/S-Video/AV to DVB-T. HDMI/YPbPr/S Encoder Modulator

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Mounting and Operating Instructions. TV gateway

RFS-805. Digital Modulator AV to COFDM. User Manual

Broadband Video over Twisted Pair Cabling. By Paul Kish Director, IBDN Systems & Standards NORDX/CDT

TV & SATELLITE LEVEL METERS

Grundig SAT Systems HEADEND RECEIVER MODULATOR HRM 391 TWIN ENGLISH

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

Power Supply Guide Version 1.0 for D-Show

Refer installation of power supplies to qualified service personnel.

Agilent PN Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

Achieving New Levels of Channel Density in Downstream Cable Transmitter Systems: RF DACs Deliver Smaller Size and Lower Power Consumption

PAL to NTSC (NTSC to PAL) Converter with 19 inch Rack (CDM-640AR)

MAINTENANCE & ADJUSTMENT

DCT User Guide CURSOR CHANNEL POWER GUIDE INFO MENU A/B SELECT

ANI Instruction Manual DIGITAL INDOOR/OUTDOOR TV ANTENNA OMNI-DIRECTIONAL WITH AMPLIFIER INTRODUCTION:

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

LT Charging Cart for Laptops

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Instruction Manual. High Definition Personal Video Recorder Digital Satellite Receiver

Model GS Port Node 1 GHz with 40/52 MHz split

Troubleshooting Guide

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Safety Warnings and Guidelines

IMPORTANT SAFETY INSTRUCTIONS

A Guide to Calibrating Your Spectrum Analyzer

MSB MODULATION DOUBLES CABLE TV CAPACITY Harold R. Walker and Bohdan Stryzak Pegasus Data Systems ( 5/12/06) pegasusdat@aol.com

MoCA 1.1 Specification for Device RF Characteristics

CMP30. User Manual.

THE R551N RECEIVER FAQ FAULT FINDING THE REDIFON COMMUNICATIONS RECEIVER R551N. Date: October 10th 1995 by: Jan Verduyn G5BBL

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

USER MANUAL. 914 Power Amplifier MODEL: P/N: Rev 1

LINE IN, LINE OUT TO TV, VIDEO IN, VIDEO OUT

TOA 900 SERIES II MIXER POWER AMPLIFIER

PERF10 Rubidium Atomic Clock

HDO700 P FIBRE OPTIC TRANSMITTER

Agilent 8753ET/8753ES Network Analyzers

Operation Manual. Multi Channel Power Amplifier DPA-430L

Movie Cube N150H. User s Manual

The Bouncer Bluetooth Stereo Speaker

Technical Standards and Requirements for Radio Apparatus Capable of Receiving Television Broadcasting

CINEMA SB100 powered soundbar speaker

RECOMMENDATION ITU-R BS.704 *, ** Characteristics of FM sound broadcasting reference receivers for planning purposes

16/32 Channel 1U Rack Mount CCTV Power Supply

Video Splitter VS-104 / VS-108 User's Manual

D3.1 / CCAP Compliant. 1.2 GHz. SignalOn Series. Forward Path Amplifier & Power Supply Products. Installation & Operation Manual

FCC CABLE RULES Technical Standards

HD udta Quick-Start Guide

FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment

Transcription:

IVIS IVIS - Indoor Video Insertion System Installation & Operation Manual

Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions. Specifications subject to change without notice. MDU Solutions is a registered trademark of ATX in the United States and/or other countries. Products or features contained herein may be covered by one or more U.S. or foreign patents. Other non-atx product and company names in this manual are the property of their respective companies.

TABLE OF CONTENTS Page 1. INTRODUCTION... 1-1 2. INSTALLATION... 2-1 3. AGILE MODULATOR OPERATION... 3-1 3.1. Agile Modulator Front Panel Controls... 3-1 4. RF LEVEL ADJUSTMENT... 4-1 5. SERVICE & SUPPORT... 5-1 5.1. Contact ATX Networks... 5-1 5.2. Warranty Information... 5-1 5.3. Safety... 5-1 MDU Solutions IVIS Indoor Video Insertion System - Instalation & Operation Manual i

Index of Figures Figures #1 IVIS Unit...1-1 #2 Agile Modulator...3-1 #3 Functional Schematic...4-1 ii MDU Solutions IVIS Indoor Video Insertion System - Instalation & Operation Manual

CHAPTER 1: INTRODUCTION INTRODUCTION 1. Introduction Figure #1: IVIS Unit This document outlines the set-up and operation of the ATX Indoor Video/Audio Inserter System IVIS. The IVIS device takes ATX s Channel Deletion Filters and integrates them with an agile or fixed Video/Audio Modulator packaged into an indoor housing. The IVIS device is mainly powered for powering the internal integrated Modulators. The IVIS device allows the operator to delete one or two RF channels from the Cable TV spectrum and reinsert new programming in Analog modulation format on those deleted channel locations. The new channels can be any Video/Audio source such as a closed circuit Video Camera or a specialty service that has been demodulated to baseband Audio and Video using a Set-Top-Box / Converter / Decoder. The latter example allows the operator to move specialty services from higher tiers to the basic service. The IVIS system can be ordered with fixed or agile modulators. If fixed modulators are ordered then their desired output channel in the Cable TV spectrum has to be specified at time of order. For both modulator types (fixed and agile) it has to be specified at time of order whether the Cable TV channels are Standard, HRC, or IRC. The RF channel deletion filter frequencies must be specified at time of order always for both modulator types as the filter is not agile. If an agile modulator is purchased, and the operator needs to change the channel to be deleted, only the channel deletion filter must be replaced. The agile modulator will easily tune to the new channel where fixed modulators need to be removed from the IVIS chassis and replaced with a modulator that is tuned to the new channel number. The chassis is easily opened and allows removal and replacement of the channel deletion filters and/or Video/Audio Modulators. Each Video/Audio Modulator has one Audio and one Video Input. Those inputs are clearly marked beneath each modulator on the IVIS device s front panel. The Audio deviation, Video depth-of-modulation, RF Output level and Video/Audio Carrier Ratio for each modulator can be adjusted from the modulator s front panel. Ensure that the Cable System s Analog Video Carrier levels present at the IVIS device s input port are between 4dBmV and 34dBmV. This ensures that the new inserted channels can be adjusted to the same Analog Video Carrier level as the rest of the Cable TV spectrum Analog channels passing through the IVIS unit. MDU Solutions IVIS Indoor Video Insertion System - Instalation & Operation Manual 1-1

CHAPTER 1: INTRODUCTION This page left intentionally blank. 1-2 MDU Solutions IVIS Indoor Video Insertion System - Instalation & Operation Manual

CHAPTER 2: INSTALLATION INSTALLATION 2. Installation The IVIS unit can be mounted in a 19 rack housing or another appropriate cabinet for secure operation. All RF and BaseBand signal ports accept standard F connectors mounted on drop cables (RG-6/u, RG-11/u or similar). Connect the incoming Cable TV feed to the INPUT port and connect the OUTPUT port to your distribution system. Connect Video and Audio signals to one or both (if two Video/Audio sources present) Modulators. In case of an Agile Modulator ensure that the Modulator Channel is set properly by checking the displayed Channel number on the Modulator s front panel. MDU Solutions IVIS Indoor Video Insertion System - Instalation & Operation Manual 2-1

CHAPTER 2: INSTALLATION This page left intentionally blank. 2-2 MDU Solutions IVIS Indoor Video Insertion System - Instalation & Operation Manual

CHAPTER 3: AGILE MODULATOR OPERATION AGILE MODULATOR OPERATION 3. Agile Modulator Operation The utilized modulators are high quality, vestigial sideband units with synthesized visual and aural carriers. The frequency agile modulators allow front panel pushwheel switch selection of Standard, HRC or IRC Cable TV channels 2 through 135, or VHF/UHF Broadcast TV channels 2 through 69. The Cable TV Channel Plan in use - Standard, HRC, or IRC has to be determined at time of ordering. The heterodyne conversion system, in conjunction with the use of a SAW filter, ensures optimum vestigial selectivity for adjacent channel operation. The modulator is designed to accept any standard audio/video source such as NTSC video and audio baseband signals from a satellite receiver, TV camera, videotape recorder, TV demodulator, Cable Set Top Box Converter, or similar signal source. The modulator is designed to accept standard (negative sync) polarity video at nominal 1 V p-p level. All level controls are located on the front panel for ease of operation. The modulator s maximum RF Output level at IVIS Output connector is +33 dbmv and is adjustable over a 10 db range on the modulator front panel by using RF Output Level control, and is adjustable an additional 20 db by utilizing the common front panel attenuator. 3.1. Agile Modulator Front Panel Controls POWER/ERROR Indicator Lights when the unit is powered. A flashing condition indicates an invalid channel setting or other conditions that would cause the unit to operate on an invalid channel. The RF output is switched OFF for flashing (ERROR) conditions. AUDIO Level Control The setting of this screwdriver adjustment determines the aural carrier deviation. Clockwise rotation increases the carrier deviation. VIDEO Level Control The setting of this screwdriver adjustment determines the video modulation level. Clockwise rotation increases the modulation depth. Channel Number Switch Sets the desired operating channel for Cable TV channels 2 through 135, or Broadcast TV channels 2 through 69. Mode Switch Sets the type of channel, Cable TV (CATV) or Broadcast TV (BCTV). The first left position of the switch (CATV +100) sets a leading 1 FOR Cable TV channels 100 through 135. A/V Ratio Control This screwdriver adjustment varies the level of the aural carrier over a range from 12 to 22 db below the visual carrier. The aural carrier should be adjusted to approximately 15 db below the visual carrier (normal operation). Clockwise rotation increases the aural carrier level. RF Output Level This screwdriver adjustment permits decreasing the RF output level a maximum of 10 db as the control is rotated counterclockwise. Figure #2: Agile Modulator CAUTION: USE AN INSULATED SCREWDRIVER BLADE WHEN ADJUSTING THE AUDIO, VIDEO, A/V, OR RF ADJUSTMENTS. THIS WILL PREVENT THE POSSIBILITY OF SHORTING CIRCUITRY TO THE FRONT PANEL IN THE EVENT THAT THE SCREWDRIVER SLIPS OUT OF THE SLOT IN THE PLASTIC SHAFT OF THE POTENTIOMETER. MDU Solutions IVIS Indoor Video Insertion System - Instalation & Operation Manual 3-1

CHAPTER 3: AGILE MODULATOR OPERATION This page left intentionally blank. 3-2 MDU Solutions IVIS Indoor Video Insertion System - Instalation & Operation Manual

CHAPTER 4: RF LEVEL ADJUSTMENT RF LEVEL ADJUSTMENT 4. RF Level Adjustment Once you have connected the INPUT and OUTPUT ports to respectively the incoming Cable Feed and the Distribution System, as well as Audio and Video Source Signals to corresponding Modulator Audio and Video Inputs, while monitoring the signal level at the IVIS -20 db RF OUT TEST Point with a Spectrum Analyzer or RF Signal Level Meter, you should be able to measure the new Modulator s Video and Audio carrier levels as well as the Video carrier levels for Analog signals or QAM Power Levels for Digital signals of the existing cable system s adjacent channels. While monitoring the meter or analyzer, adjust the Modulator s Video Carrier Levels by adjusting the common attenuator on the front of the IVIS unit until you obtain an equal level as the adjacent Cable system s Analog channel Video Carrier Level, or 6 db higher than the adjacent 256QAM Digital signal Power Level or 10 db higher than the adjacent 64QAM Digital signal Power Level. If you require additional and/or finer RF Output Level adjustment for either of the two modulators mounted in the IVIS, adjust the RF Output Level potentiometer on the front panel of the Modulator as described in previous section. From the factory the modulator front panel RF Output Level potentiometer is set to maximum RF output level, this will give you the best Signal to Noise Ratio. Always attempt to make all Video Carrier Level adjustments using the common attenuator on the IVIS front panel. Verify that the Modulator s Audio carrier is 15 db below the Video Carrier. If not adjust the A/V potentiometer on the Modulator s front panel until the Audio to Video Ratio is set to -15 db. All previous measurements are to be done using a spectrum analyzer or RF signal level meter. If using Spectrum Analyzer for measuring Analog and Digital RF Signals: Be sure to have taken into account RBW settings and have made corrections to the Spectrum Analyzers Reading while measuring Digital QAM Signals. Make use of Band Power Measurement option for measuring Digital QAM signals, if supported by Spectrum Analyzer. If using RF Signal Level Meter for measuring Analog and Digital RF Signals: Be sure to have selected the correct measurement mode for measuring Analog and Digital Signals. After RF level adjustment is finished, the Video Carrier Levels of the inserted one or two new Analog signals shall equal the Video Carrier Levels of the Cable system s existing adjacent Analog signals Video Carriers or be 6 db higher than adjacent 256QAM signals or be 10 db higher than adjacent 64QAM signals. If required, set the Audio deviation by adjusting the AUDIO potentiometer on the front panel of the modulator as described in previous section. Also, if required, set the VIDEO Modulation depth by adjusting the VIDEO potentiometer on the front panel of the modulator as described in previous section. CHANNEL DELETION FILTERS RF IN FI L TER 1 DIRECTIONAL COUPLER FI L TER 2 RF OUT VIDEO IN 1 AUDIO IN 1 MODULATOR 1 VARIABLE ATTENUATOR VIDEO IN 2 AUDIO IN 2 MODULATOR 2 COMBINER -20 db TEST POINT 100-240 V AC IN POWER SUPPLY INDOOR VIDEO INSERTION SYSTEM Figure #3: Functional Schematic MDU Solutions IVIS Indoor Video Insertion System - Instalation & Operation Manual 4-1

CHAPTER 4: RF LEVEL ADJUSTMENT This page left intentionally blank. 4-2 MDU Solutions IVIS Indoor Video Insertion System - Instalation & Operation Manual

CHAPTER 5: SERVICE & SUPPORT SERVICE & SUPPORT 5. Service & Support 5.1. Contact ATX Networks Please contact ATX Technical Support for assistance with any ATX products. Please contact ATX Customer Service to obtain a valid RMA number for any ATX products that require service and are in or out-of-warranty before returning a failed module to the factory. DIGITAL VIDEO SUPPORT LINE Tel: (905) 428-6068 Toll Free: (800) 565-7488 (USA & Canada only) Press * 3 for Technical Support Then press 1 for Digital Video Products Email: digitalvideosupport@atxnetworks.com CUSTOMER SERVICE ATX Networks 1-501 Clements Road West Ajax, ON L1S 7H4 Canada Tel: (905) 428-6068 Toll Free: (800) 565-7488 (USA & Canada only) Press * 1 for Customer Service Fax: (905) 427-1964 Toll Free Fax: (866) 427-1964 (USA & Canada only) Web: www.atxnetworks.com Email: support@atxnetworks.com 5.2. Warranty Information All of ATX Networks products have a 1-year warranty that covers manufacturer s defects or failures. 5.3. Safety IMPORTANT! FOR YOUR PROTECTION, PLEASE READ THE FOLLOWING: WATER AND MOISTURE: Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through openings. POWER SOURCES: The device should be connected to a power supply only of the type described in the operating instructions or as marked on the device. GROUNDING OR POLARIZATION: Precautions should be taken so that the grounding or polarization means of the device is not defeated. POWER CORD PROTECTION: Power supply cords should be routed so that they are not likely to be pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the device. SERVICING: The user should not attempt to service the device beyond that described in the operating instructions. All other servicing should be referred to qualified service personnel. FUSING: If your device is equipped with a fused receptacle, replace only with the same type fuse. Refer to replacement text on the unit for correct fuse type. MMDU Solutions IVIS Indoor Video Insertion System - Instalation & Operation Manual 5-1

1-501 Clements Road West, Ajax, ON L1S 7H4 Canada Tel +1 (905) 428-6068 Toll Free +1 (800) 565-7488 Fax +1 (905) 427-1964 Toll Free Fax +1 (866) 427-1964 www.atxnetworks.com support@atxnetworks.com Printed in Canada Rev. 04/15 (ANW0781)