Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet



Similar documents
Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet

Version: 1.0 TWO HANDLES INWALL WATERFALL FAUCET INSTALL GUIDE

Watts Pure Water Systems

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

INSTALLATION INSTRUCTIONS BL-8704

INSTALLATION INSTRUCTIONS SENSOR OPERATED LAVATORY FAUCET. EBF-85 and EBF-187 Battery Powered, Sensor Operated Lavatory Faucet

INSTALLATION INSTRUCTIONS MK-8704

STABITHERM INSTALLATION & SERVICE BOOKLET

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Stainless Steel Single and Dual Circulation Kits

Fixtures - Parts - Accessories to shampoo bowls

What is Thermal Expansion?

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Porcelain Vessel Sink Installation

Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Common Causes of High Water Bills

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

MAC FAUCETS. Owner s Manual. Models: FA444

Installation Instructions

How To Fix A Leaky Water Heater

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

How To Replace A Reverse Osmosis Water Tank

Cadet Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

PLUMBING. venturehomes.com

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Installation Instructions AQ-5100, AQ-5200 & AQ-5300 Under Counter Water Filter Single Stage (5100), Two Stage (5200) and Three Stage (5300) systems

detection kit the water leak water leaks: What you should know A helpful guide for locating indoor and outdoor water leaks Getting Ready

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS P-TRAP SUPPLY KIT Model: RH-3016 These instructions are a guideline for a basic installation

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

CW-4622 INSTALLATION INSTRUCTIONS CB-4622 RISER KIT TO SUIT BLACK LEVER EXPOSED VALVES & BATH/SHOWER VALVES

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS GEO-BOOSTER TM

Electric Mini Tank Water heaters GL GL 4 - GL 6+

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA. REF Rev. L

Installation guide Nordic mixer taps. Before installing read this guide first

NITROUS TRANSFER PUMP INSTRUCTIONS

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

PArt# spout Length Adjusts /2 to 8-1/ /2 to 8-1/ /2 to 8-1/ /2 to 8-1/2. PArt# FIts Adjusts

Geyser-R Heat pump water heater Installation manual

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

SHOWERS SHOWERS

INSTRUCTION MANUAL A REVISION A. Series E1 and E3 Instant Hot Water Recirculating Systems

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Plumbing Code Sections For Commercial Food Facilities

Plugging Home Drains to Prevent Sewage Backup

H41 Electrical Stage Aft Air Conditioner Unit Installation

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Installation and maintenance instructions

OWNER S MANUAL. FOOTWORKS tm Faucet Controller. Foot Operated Faucet Control Valves for Commercial Sinks

Installation Instructions

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

Installation Instructions

Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

Leak Detector Guide. Your Guide to Home Water Conservation

Installation Instructions / Warranty

PLUMBING CARE AND REPAIR

Isotemp Basic, Slim/B & Slim Square

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

This section gives you some helpful information and tips on running your home and the equipment in it.

A High Bill Usually Means a Leak

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

What to Expect From the Examination. How to Study the Plumbing Codes

Custom Shower Design Guide

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Shower Handbook (Also covers 650 chrome variant)

Installation and Operation Manual

REPLACE A TOILET FILL VALVE

Introducing. The Flood Free Zone. The Only Sensible Way To Prevent And Control Household Water Leaks

INSTANT HOT WATER RECIRCULATING SYSTEM

A Do-It-Yourself Home Water Audit

Plumbing Identification and Damage Assessment Guide

INSTALLATION INSTRUCTIONS

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

SWF Home Inspections

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Quartz Top Installation Instructions See separate installation instructions for installing your new Vanity.

Transcription:

Providing Temperature Regulated Warm Water to your Sanicare Hand Spray Bidet

The Sanicare Thermostatically Controlled Mixer Valve allows you to precisely control the temperature of the warm water for your Hand Spray Bidet. When used with the Sanicare Hand Spray Wall Mount Bracket with Integrated Automatic Shut-Off Valve it provides the ultimate hand spray bidet installation. There are two general types of installations: Retrofit installation into the sidewall of the vanity (basin) cabinet when the cabinet is located next to the toilet. This is the easiest and most convenient installation since all the plumbing is done inside the Vanity Cabinet and does not require access to the inside of the bathroom walls. New Construction or In-Wall Plumbing Retrofit Installation is required if the vanity cabinet is not located conveniently beside the toilet or if you do not wish to install your Hand Bidet on the side of the Vanity Cabinet.

Overview of General Installation of Thermostatic Mixing Valve to provide temperature regulated water to your Sanicare Hand Spray Bidet Hand Spray Bidet Anti-Siphon Vacuum Breaker The hot and cold supply lines to the mixer valve must be equipped with shut off valves (stops) to allow for servicing of the mixer valve and to shut-off the water in the event of a leak or rupture. Wall Mounting Bracket With Automatic Shut-Off An anti-siphon (back flow restrictor) valve must be installed between the Hand-Bidet and the Thermostatic Mixer Valve to prevent any contaminated toilet water from siphoning back into the supply lines in the event that the hand- Bidet falls into the toilet bowl and there is a loss of line pressure. Flexible Hose Hot Water Supply Temperture Mixing Valve Cold Water Supply A shut off valve must be installed before the Hand-Bidet flexible hose and should be turned off whenever the Hand-Bidet is not in use. This is a standard plumbing practice that should be used whenever a flexible hose is used (such as with a washing machine) to protect your property from water damage in the event that a hose fails or ruptures. For elegance of installation and ease of use we highly recommend the use of our Wall Bracket with Integrated Automatic Shut-Off Valve that shuts off the water supply when the Hand-Bidet Spray Handle is inserted in the Wall Bracket.

Vanity Cabinet Installation of Thermostatic Mixing Valve Use when your Vanity Cabinet is located next to your toilet and you wish to install the Mixer Valve and Hand Spray Bidet onto the side of the Vanity Cabinet. Existing Flexible Hose to Sink 3/8 x 3/8 x 3/8 Add-A-Line Tee Connector If your Vanity Sink (Basin) Cabinet is conveniently located next to your Toilet and you wish to install the Thermostatic Mixing Valve and the Hand Spray Bidet Mounting Bracket onto the side wall of the Vanity Cabinet then you can do an easy Retro-Fit installation that doees not require access to any of the in the wall plumbing. 3/8 x 1/2 Flexible Faucet Connector Hose Existing Shut Off Valve Under Vanity Sink To Mixing Valve Refer to the diagram on the previous page: 1. First determine the placement locations for the Hand Spray Wall Mounting Bracket and the Mixing Valve. Make sure that these locations are ergonomically confortable to reach when you are sitting on the toilet. Also make sure that these locations provide for adequate working room inside the Vanity Cabinet and don t interfere with the Sink/ Basin location. 2. 3. 4. 5. 6. 7. 8. Cut the necessary holes into the side of the vanity Cabinet and mount both the Thermostatic Mixer Valve and the Hand Spray Wall Mounting Bracket. Shut off the hot and cold water supply lines at the Shut- Off Valves under the vanity and release the pressure by turning on both the hot and cold faucets. Unscrew the end of the Flexible Hose from the Cold Water Shut-Off Valve and install a Tee Connector. Then Re-connect the Flexible Faucet Hose to the top of the Tee Connector. Connect a suitable length of 3/8 x 1/2 Flexible faucet Hose to the branch of the Tee Connector and connect the other end of the hose to the Cold Water Inlet of the Mixing Valve. Repeat steps 4 & 5 for the Hot Water hoses. Connect the Anti-Siphon Vacuum Breaker (Back flow preventer) to the top outlet of the Mixing Valve. Install a suitable length of 1/2 x 1/2 Flexible Faucet Hose to the outlet of the Vacuum Breaker and connect it to the inlet of the Hand Spray Mounting Bracket. Note: If space is tight or the Vacuum Breaker requires a specific orientation, you way wish to add one or more 1/2 x 1/2 x 90 deg. Street Elbow fittings to achieve a tighter radius curve than is possible with the flexible hoses.

9. 10. 11. 12. Insert a washer between the hex nut end of the Hnad Spray Bidet Flexible Hose and connect it to the outlet of the Wall Mounting Bracket. Before connecting the Hand Spray Bidet to the Flexible hose you will need to flush the new plumbing you have just instslled to rid the sistem of any dirt particles. Point the end of the Flexible Hose into the Toilet bowl while you turn on the Hot & Cold Shut-Off Valves to flush the system. Turn the valves back off. Using another rubber wahere between the Flexible Hose and the hand Spray Bidet Nozzle and tighten the connection. Now turn both Shut-Off Valves back on and check the new plumbing for any leaks. This completes your Retro-Fit installation!

In-Wall New-Construction or Retro-Fit Installation of Thermostatic Mixing Valve Select the preferred locations for the Thermostatic Mixing Valve and Hand Spray Bidet Wall Mount Bracket giving careful consideration to the convenience and ergonomics when seated on the toilet. Depending on the location, access to water supply lines, access to the other side of the wall, etc. your particular Hand Spray Bidet installation will vary to suit the construction and local plumbing codes. Please consult a qualified plumber and use the diagram below as a guide to the outline of the installation Wall Mounting Bracket with integrated Automatic Shut-Off valve Street Elbow 90 Anti-Siphon Vacuum Braker Back-Flow Preventer Ball Valve Stop Adapter Ball Valve Stop Hand Spray Bidet Flexible Hose Mixer Valve

Visit Sanicare for all your Bidet Product needs 9005 West Sahara Avenue Las Vegas, NV 89117 http://www.sanicare.com Email: sales@sanicarebidet.com Ph (800) 878-4791 Ph (877) 852-2823 Outside USA +1 (254) 592-8076 Fax (281) 840-4452 Please note that all times are Central Time. Sales Hours Monday thru Friday: 8:00am-8:00pm Saturday: 8:00am-1:00pm Sunday: Closed Customer Service Hours Monday thru Friday: 8:00am-8:00pm Saturday: 8:00am-1:00pm Sunday: Closed Technical Support Hours Monday thru Friday: 8:00am-6:00pm Saturday: Closed Sunday: Closed