PowerPanel for Linux Software



Similar documents
UPS MONITORING SOFTWARE USER MANUAL

PowerPanel Business Edition USER MANUAL

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

Future Technology Devices International Ltd. Mac OS-X Installation Guide

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Wavelink Avalanche Mobility Center Linux Reference Guide

UPSentry Smart User s Manual. Shutdown Management Software. for Mac OS X 10.2

Ambient Temperature In Range Probe X

UPSMON PRO Linux --- User Manual

BrightStor ARCserve Backup for Linux

Basic Use of the SPC Feature on 1100R+/H+ Testers

Liebert MultiLink. User Manual - Fundamental & Advanced

PowerPanel Personal Edition User Manual. User Manual. PowerPanel Personal Edition. Rev /12/2

Netwatch Installation For Windows

TouchKit driver user guide for Linux

Netop Remote Control for Linux Installation Guide Version 12.22

Title: Documentation for the Pi-UPS-Monitor-App

Future Technology Devices International Ltd. Mac OS X Installation Guide

PowerPanel Personal Edition User Manual. User Manual. PowerPanel Personal Edition. Rev /02/24

Expresso Quick Install

PowerPanel Business Edition Installation Guide

AMD Catalyst Installer Notes for Linux

Installation Guide for LynxClient

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

SVA025 Netcom2 FAQ Rev 1. Mitsubishi Netcom 2 FAQ

How To Install The Safenet-Inc.Com Software On A Pc Or Mac Or Macintosh (For A Powerpoint) With A Powerline (For Windows) Or Ipad (For Mac) With The Safetime (For Pc

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

JobScheduler Installation by Copying

Uninterruptible Power Supply Software. User s Manual

QuickBooks Enterprise Solutions. Linux Database Server Manager Installation and Configuration Guide

Server Monitoring. AppDynamics Pro Documentation. Version Page 1

User s Manual Network Management Card

CycleServer Grid Engine Support Install Guide. version 1.25

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

Monitoring Clearswift Gateways with SCOM

Getting Started with RES Automation Manager Agent for Linux

USB Driver. Installation Guide for H5 Devices

Manufacturing Flash Tool

McAfee Firewall Enterprise

End-User troubleshooting guide For Sentinel SuperPro/UltraPro and Sentinel Hardware Keys

AlienVault Unified Security Management (USM) 4.x-5.x. Deploying HIDS Agents to Linux Hosts

MPLAB IDE 64-Bit USB Device Drivers Installation

HASP Troubleshooting Guide

IBM WebSphere Application Server V8.5 lab Basic Liberty profile administration using the job manager

Course: 8911B: Installation and Deployment in Microsoft Dynamics CRM 4.0

NetWrix USB Blocker. Version 3.6 Administrator Guide

Installation and Control in Linux

DIRECT INTERNET 3. Install Guide for the Mac OS Operating System

Microsoft Windows Built-In Serial and USB UPS Support

Maintaining the Content Server

Introduction. What is Unbound and what is DNSSEC. Installation. Manual for Unbound on Windows. W.C.A. Wijngaards, NLnet Labs, October 2010

USB 2.0 Flash Drive User Manual

Infinity C Reference Guide

Administrator s Guide

Contents. Business Everywhere user guide. 1. Introduction. 2. How to Install/Uninstall Business Everywhere. 3. The Business Everywhere interface

How to Install Applications (APK Files) on Your Android Phone

Intuit QuickBooks Enterprise Solutions. Linux Database Server Manager Installation and Configuration Guide

CurveMaker v2.1 DYNAFS programmable ignition software

Ash Capture Control User Guide

User s Guide. PowerAlert Software Versions / /

UPS-Management Software

EMC AVAMAR 6.0 GUIDE FOR IBM DB2 P/N REV A01 EMC CORPORATION CORPORATE HEADQUARTERS: HOPKINTON, MA

Floating License Installation Guide for Windows

PMOD Installation on Linux Systems

Windows Server 2008 Hyper-V, Windows Server 2008 Server Core Installation Notes

PL-2303 (Chip Rev H, HX, X) USB to Serial Adapter Windows Driver Installer Manual

Network Management Proxy 5 User manual

NetWrix USB Blocker Version 3.6 Quick Start Guide

Release Notes for McAfee(R) VirusScan(R) Enterprise for Linux Version Copyright (C) 2014 McAfee, Inc. All Rights Reserved.

Card Swipe and ibutton Access Configuration

FreeBSD OpenVPN Server/Routed - Secure Computing Wiki

Using SNMP with Content Gateway (not V-Series)

PowerShield SNMP Adaptor

USB HSPA Modem. User Manual

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

HP UPS Management Module Overview

User Manual (DA-70155)

How To Run A Password Manager On A 32 Bit Computer (For 64 Bit) On A 64 Bit Computer With A Password Logger (For 32 Bit) (For Linux) ( For 64 Bit (Foramd64) (Amd64 (For Pc

Eaton NetWatch NetWatch installation and configuration guide VMware ESX 3 Virtual architecture

UPSentry Smart User s Manual. Shutdown Management Software. for Mac OS X 10.1

Manual. Sealer Monitor Software. Version

USB Port PCI Express Card

How To Install Storegrid Server On Linux On A Microsoft Ubuntu 7.5 (Amd64) Or Ubuntu (Amd86) (Amd77) (Orchestra) (For Ubuntu) (Permanent) (Powerpoint

IT6204 Systems & Network Administration. (Optional)

RS485 Adapters. User Manual October 26, 2008 V1.02 Copyright Light O Rama, Inc. 2006, 2007, 2008 SC485 USB485B USB485 USB485-ISO

D8X / D16X IPHONE INTERFACE

Chapter 3 Startup and Shutdown This chapter discusses how to startup and shutdown ETERNUSmgr.

IBM WebSphere Partner Gateway V6.2.1 Advanced and Enterprise Editions

... 2 HARDWARE AND FIRMWARE

USB TO SERIAL CONVERTER

Tripp Lite PowerAlert

SIP-DECT Knowledge Base SIP-DECT System Update

Honeywell Internet Connection Module

SAS Marketing Optimization. Windows Installation Instructions for Hot Fix 51mo14

1 Basic Configuration of Cisco 2600 Router. Basic Configuration Cisco 2600 Router

QuickSpecs. Models. HP UPS Management Module. HP UPS Management Module. Overview

Installing CM4D Reporter with Microsoft SQL Server Express R2 x64 for Windows 7

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

How to install software on VMware ESXi 4.0/4.1

Transcription:

PowerPanel for Linux Software User s User's Manual PowerPanel Business Edition Rev. 1 2010/08/26 Rev. 1.5.11 2009/09/03

Table of Contents Getting Help 2 Getting the UPS Status... 2 Getting the Daemon Settings... 2 Setup the UPS and Daemon... 3 Setup Action for Power Failure as Example... 3 Setup Action for Low Battery as Example... 3 Turn UPS s Alarm On and Off... 3 Mute UPS s Alarm Temporary... 3 Request UPS to Do A Battery Test... 4 Daemon Configuration... 4 Daemon Event Log... 4 Troubleshooting... 4 1

Getting Help pwrstat -help Listing help contents with each direction and options for pwrstat command. The other way, you can get more information about pwrstat and pwrstatd man page helps as below: man pwrstat man pwrstatd Getting the UPS Status pwrstat -status Listing current UPS properties and status as following. Properties: Model Name... UPS CP585 Rating Voltage... 120 V Rating Power... 515 VA (335 Watt) Current UPS status: State... Normal Power Supply by... Utility Power Utility Voltage... 111 V Load... 0 % Remaining Runtime... 60 min. Battery Capacity... 100 % Note: These display items depends on UPS specification. Getting the Daemon Settings pwrstat -config Listing current daemon settings as following. Daemon Configuration: Alarm... On Action for Power Failure: Delay time since Power Failure... 60 sec. Run script command... On Path of script command... /etc/pwrstatd-powerfail.sh Duration of command running... 1 sec Enable shutdown system... on 2

Action for Battery Low: Delay time since Battery Low... 5 sec. Run script command... On Path of script command... /etc/pwrstatd-lowbatt.sh Duration of command running... 1 sec Enable shutdown system... on Setup the UPS and Daemon Setup Action for Power Failure as Example pwrstat -pwrfail -delay 60 -active on -cmd /etc/pwrstatd-powerfail.sh -duration 1 -shutdown on As above setting, it will take 1 second to run a shell script named /etc/pwrstatd-powerfail.sh and shutdown system since utility power has failure for 1 minute. Setup Action for Low Battery as Example pwrstat -lowbatt -delay 5 -active on -cmd /etc/pwrstatd-lowbatt.sh -duration 1 -shutdown on As above setting, it will take 1 second to run a shell script named /etc/pwrstatd-lowbatt.sh and shutdown system since UPS's battery capacity has low then a threshold for 5 seconds. Note: 1. The battery capacity Threshold can be changed in file /etc/pwrstatd.conf. 2. The parameter -pwrfail and -lowbatt are exclusively. 3. The unit of option -delay is second. 4. Both shell script /etc/pwrstatd-powerfail.sh and /etc/pwrstatd-lowbatt.sh were copied during installation procedure. 5. At least one of parameters -delay, -active, -cmd, -duration or -shutdown is necessary. 6. The option of -cmd can be any shell script in system, but it will be run by root authority. 7. The default action setting for both of -pwrfail and -lowbatt are same as above setting of example. Turn UPS s Alarm On and Off pwrstat -alarm on pwrstat -alarm off To turn UPS's alarm on or off. Mute UPS s Alarm Temporary pwrstat -mute To mute UPS's alarm for this power event until next one. 3

Request UPS to Do A Battery Test pwrstat -test To verify the UPS will work well in battery power. Daemon Configuration The daemon's configuration file is located at /etc/pwrstatd.conf. Daemon Event Log The daemon will record the power event in pwrstatd.log log file, which can be found on /var/log directory. Troubleshooting 1. What kind of UPS is supported by PowerPanel for Linux? a. The pwrstatd support USB port and Serial port to monitor UPS. b. A UPS is designed under architecture of USB HID/Power Class; A UPS has DB-9 connector for RS-232 or Dry-Contact communication. 2. Cannot establish communication with UPS. a. Ensure UPS type is supported by PowerPanel for Linux. b. Ensure USB or Serial cable is connected between UPS and computer. Directly connect computer and UPS without USB Hub is helpful to solve if which have communication problem. c. Try to unplug and plug the USB cable with UPS. d. Ensure hid device can be found at directory of /dev/hiddev, /dev/usb/hiddev, /dev/usb/hid/hiddev such as hiddev0 if UPS is connected by USB cable. Ensure hid device can be found at directory of /dev such as ttys0 if UPS is connected by serial cable. e. Ensure Linux kernel version is more than 2.4.22 or 2.6. Ensure kernel module usbhid.ko is loaded on system in kernel 2.4 and hid.o in kernel 2.6. 3. Cannot installation or un-installation a. Ensure user account is root, because the installation/un-installation needs root privilege to setup system. b. The target Linux may not work with our installation procedure, please refer to file doc/deploy-guide to get more detail information. 4. pwrstat have no function. a. Ensure pwrstatd is working. b. Ensure prohibit-client-access option is set as no in pwrstatd configuration file. 5. The pwrstatd daemon cannot detect the UPS which has H2C USB adapter. 4

a. Ensure Linux system have libusb library. It can be found at /usr/lib directory. b. Ensure the libusb so name is libusb-0.1.so.4. c. If libusb soname version is less than libusb-0.1.so.4, please go to rpmfind or sourceforge web site download the libusb rpm package and install it. The rpmfind and sourceforge download web site are shows as below: rpmfind web site, http://rpmfind.net sourceforge web site, http://sourceforge.net 5