How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip



Similar documents
NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

NI USB-5681 RF Power Meter Specifications

NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

This document lists specifications for the NI PXIe-4139 (NI 4139) precision system sourcemeasure

INSTALLATION INSTRUCTIONS 160-Pin Cable for the NI PXI-2530B

NI 653x Cable Adapter

CompactRIO crio-9052

Contents. SPECIFICATIONS AND FEATURES GUIDE NI Serial Hardware

PXI Express Chassis with Integrated MXI-Express Remote Controller

NI USB-6008/6009 OEM USER GUIDE

This document lists the specifications for the NI PXIe-5160, 500 MHz digitizer.

NI 9211 Datasheet DATASHEET. 4 TC, ±80 mv, 24 Bit, 14 S/s Aggregate

USB-6008/6009. Contents USER GUIDE. This user guide describes how to use the National Instruments USB-6008/6009 data acquisition (DAQ) devices.

Digital input modules

Cisco Unified IP Phone Power Injector

NI 6034E/6035E/6036E Family Specifications

Kvaser Mini PCI Express User s Guide

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

TX OPEN RS232/485 module

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

NI 6601/6602. Contents CALIBRATION PROCEDURE. ni.com/manuals

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

Coupling Microsoft Excel with NI Requirements Gateway

INSTALLATION GUIDE. AXIS T8133 Midspan 30W

AXIS T81B22 DC 30W Midspan

EGSTON Standard E2xFxWx 12W

Duct Humidity Transmitter

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Application Server V240 Platform

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

How To Build A Cisco Uniden Computing System

Cisco TelePresence MCU 4500 Series safety and compliance information

DAQ Getting Started Guide

Datasheet Fujitsu ETERNUS LT20 S2

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Data Sheet FUJITSU Storage ETERNUS LT20 S2 Tape System

Dialogic DSI SS7LDH4 Network Interface Board

4-Drive, In-Chassis High-Speed Data Storage Module

Scout 1U Rackmount Computer

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

I STAR COMPUTER CO., LTD

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Apalis T30 Mezzanine. Preliminary Datasheet

Cisco 7816-I5 Media Convergence Server

Using the NI 17xx Smart Camera Direct Drive Lighting Controller

MADRIX NEO Quick Start Guide & User Manual

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

AXIS 291 1U Video Server Rack Installation Guide

STRATO LED Drivers 70W, Single output

IFS SP-PoE Splitter User Manual

Name Description P/N. Programmer Programmer with calibration function SDD-AAPNP. Parameter Min. Typ. Max. Notes. (Vo+ - Vo-) - Voltage

CompactLogix Power Supplies Specifications

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

ADACSNET USB Control Module

Electronic Control Devices The European Product Catalogue 2007

DATASHEET FUJITSU ETERNUS LT250 TAPE LIBRARY

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

R5000 Uninterruptible Power System (UPS) Overview

USB Plus+ RFID Reader Setup Guide

R5000 Uninterruptible Power System (UPS) Overview

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

3500/62 Process Variable Monitor

How To Backup To Disk With Deduplication On An Fujitsu Ecson Cser800 S4 Data Protection Appliance

Pocket Tach 99 (PT99) Non-Contact Tachometer

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

NI PXI Installing Your PXI Board INSTALLATION GUIDE

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

How To Use An Fujitsu Ces800 S5 Backup Appliance

Datasheet FUJITSU Storage ETERNUS LT250 TAPE LIBRARY

Data Sheet FUJITSU Storage ETERNUS CS800 S5

Dear Customer! Thank you for choosing our product.

1000 BASE-X SFP. Key Features DATA SHEET HIGHLIGHTS 1000BASE-SX 1000BASE-LX 1000BASE-ZX 1000BASE BX-D*

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

US Installation Manual Smappee Monitor

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Dialogic I-Gate 4000 Session Bandwidth Optimizer Core

USB-to-Data Highway Plus Cable

X2 LR Optical Transponder, 10Km Reach

SyncLink GT2/GT4 Serial Adapter

DATA SHEET DVI - HDCP Extension Cable

Coupling Microsoft Visio with NI Requirements Gateway

MACTek Corporation. USB HART Interface. Users Manual

NX safety stand-alone

Gigabit eco-friendly Ethernet Switch AT-GS900/8. Installation Guide Rev. A

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card for Cisco 2821, 2851, and 3800 Series Integrated Services Routers

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Power Meter Series 700

Models HP Dock Connector to Ethernet & VGA Adapter New! HP EliteFolio Ethernet & VGA Adapter HP HDMI to DVI Adapter

804 Ti Stand. Manual EN

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Transcription:

NI 6585 Specifications This document lists the specifications of the National Instruments 6585 FlexRIO low-voltage differential (LVDS) adapter module. Pair these specifications with your FPGA module specifications. Refer to the Getting Results with the NI PXI-6585R document for instructions on how to install and configure the NI PXI-6585R. These specifications are typical at 25 C unless otherwise noted. Channel Specifications per Connector Number of DDC connectors... 2, DDCA and DDCB Number of digital I/O channels... 42 total (16 data, 5 PFI per DDC connector) Direction control of data channels... Per channel Power up state... Drivers disabled, 100 Ω differential impedance Acquisition Acquisition voltage levels Differential voltage threshold... ±50 mv Voltage range... 0 V min, 2.4 V max Input impedance... 100 Ω differential nominal Maximum data rate... 200 MBit/s single data rate (SDR); 300 MBit/s double data rate (DDR) Generation Generation voltage levels (50 Ω LVDS load) Min Max Differential 247 mv 454 mv Common Mode 1.125 V 1.375 V Note Generation expects 100 Ω termination at the destination in addition to the 100 Ω input termination of the NI 6585. Characteristic impedance...100 Ω differential nominal Maximum data rate...200 MBit/s single data rate (SDR); 300 MBit/s double data rate (DDR) UserGclkLvttl on UserGclkLvds on Data from Output Enable from Data to Figure 1. Clock Input Notes: Applies to each data and PFI channel. CLOCK OUT is the same as PFI 0. DDCA Global Clock In DDCB Global Clock In Figure 2. DIO <0..15> Data Channel, PFI <0..4> DDC 100 Ω DDC

Pinout and Signal Information DDCA DDCB PFI 4 PFI 4+ PFI 2 PFI 2+ DDC CLK OUT /PFI 0 DDC CLK OUT+/PFI 0+ DIO15 DIO15+ DIO13 DIO13+ DIO11 DIO11+ DIO9 DIO9+ DIO7 DIO7+ DIO5 DIO5+ DIO3 DIO3+ DIO1 DIO1+ 68 34 67 33 66 32 65 31 64 30 63 29 62 28 61 27 60 26 59 25 58 24 57 23 56 22 55 21 54 20 53 19 52 18 51 17 50 16 49 15 48 14 47 13 46 12 45 11 44 10 43 9 42 8 41 7 40 6 39 5 38 4 37 3 36 2 35 1 PFI 3 PFI 3+ PFI 1 PFI 1+ GLOBAL CLK 0 GLOBAL CLK 0+ DIO14 DIO14+ DIO12 DIO12+ DIO10 DIO10+ DIO8 DIO8+ DIO6 DIO6+ DIO4 DIO4+ DIO2 DIO2+ DIO0 DIO0+ DDCA DDCB PFI 4 PFI 4+ PFI 2 PFI 2+ DDC CLK OUT /PFI 0 DDC CLK OUT+/PFI 0+ DIO15 DIO15+ DIO13 DIO13+ DIO11 DIO11+ DIO9 DIO9+ DIO7 DIO7+ DIO5 DIO5+ DIO3 DIO3+ DIO1 DIO1+ 68 34 67 33 66 32 65 31 64 30 63 29 62 28 61 27 60 26 59 25 58 24 57 23 56 22 55 21 54 20 53 19 52 18 51 17 50 16 49 15 48 14 47 13 46 12 45 11 44 10 43 9 42 8 41 7 40 6 39 5 38 4 37 3 36 2 35 1 PFI 3 PFI 3+ PFI 1 PFI 1+ GLOBAL CLK 0 GLOBAL CLK 0+ DIO14 DIO14+ DIO12 DIO12+ DIO10 DIO10+ DIO8 DIO8+ DIO6 DIO6+ DIO4 DIO4+ DIO2 DIO2+ DIO0 DIO0+ Figure 3. NI 6585 Pinout NI 6585 Specifications 2 ni.com

Table 1 contains pin location and signal information for the NI 6585. Note DIO <0..15>+/, PFI <0..4>+/, and DDC CLOCK OUT appear on both connectors, DDCA and DDCB. Table 1. NI 6585 DDC Connector Pins Signal Name Pin(s) Signal Type Signal Description GLOBAL CLOCK 0+ 26 on DDCA Clock Input terminal for the external clock source, which can GLOBAL CLOCK 0 27on DDCA be used for dynamic acquisition or generation. GLOBAL CLOCK 1+ GLOBAL CLOCK 1 26 on DDCB 27 on DDCB DIO <0..15>+ 2, 5, 8, 11, 14, 17, 20, 23, 37, 40, 43, 46, 49, 52, 55, 58 DIO <0..15> 3, 6, 9, 12, 15, 18, 21, 24, 38, 41, 44, 47, 50, 53, 56, 59 Data Data Positive terminal of LVDS digital I/O data channels 0 through 15. Negative terminal of LVDS digital I/O data channels 0 through 15. DDC CLOCK OUT+/ PFI 0+ DDC CLOCK OUT / PFI 0 61 Clock/Data Positive output terminal for the exported Sample clock/ Positive Programmable Function Interface terminal 0 62 Clock/Data Negative output terminal for the exported Sample clock/ Negative Programmable Function Interface terminal 0 PFI <1..4>+ 29, 64, 32, 67 Data Positive terminal of the Programmable Function Interface LVDS digital I/O channels 1 through 4. PFI <1..4> 30, 65, 33, 68 Data Negative terminal of the Programmable Function Interface LVDS digital I/O channels 1 through 4. 1, 4, 7, 10, 13, 16, 19, 22, 25, 28, 31, 34, 35, 36, 39, 42, 45, 48, 51, 54, 57, 60, 63, 66 Ground Ground reference for signals. National Instruments Corporation 3 NI 6585 Specifications

Table 2 lists the NI 6585 connector signals and corresponding the FPGA module signals necessary for designing a custom CLIP. Table 2. NI 6585 Connector Signals and Signals NI 6585 Connector Signal Name GPIO Out GPIO Out Enable GPIO In DDCA GLOBAL CLOCK 0 GClk_SE DIO 0+/ GPIO_30_n GPIO_31 GPIO_31_n DIO 1+/ GPIO_12_n GPIO_13 GPIO_13_n DIO 2+/ GPIO_32 GPIO_32_n GPIO_15_n DIO 3+/ GPIO_14 GPIO_14_n GPIO_15 DIO 4+/ GPIO_27_n GPIO_28 GPIO_28_n DIO 5+/ GPIO_9_n GPIO_10 GPIO_10_n DIO 6+/ GPIO_29 GPIO_29_n GPIO_30 DIO 7+/ GPIO_11 GPIO_11_n GPIO_12 DIO 8+/ GPIO_22 GPIO_22_n GPIO_23 DIO 9+/ GPIO_6_n GPIO_7 GPIO_7_n DIO 10+/ GPIO_26 GPIO_26_n GPIO_27 DIO 11+/ GPIO_8 GPIO_8_n GPIO_9 DIO 12+/ GPIO_19 GPIO_19_n GPIO_20 DIO 13+/ GPIO_3_n GPIO_4 GPIO_4_n DIO 14+/ GPIO_20_n GPIO_21 GPIO_21_n DIO 15+/ GPIO_5 GPIO_5_n GPIO_6 DDC CLOCK OUT+/PFI 0+ DDC CLOCK OUT /PFI 0 GPIO_0 GPIO_0_n GPIO_23_n PFI 1+/ GPIO_1 GPIO_1_n GPIO_24 PFI 2+/ GPIO_16 GPIO_16_n GPIO_24_n PFI 3+/ GPIO_17 GPIO_17_n GPIO_25 PFI 4+/ GPIO_18 GPIO_18_n GPIO_25_n NI 6585 Specifications 4 ni.com

Table 2. NI 6585 Connector Signals and Signals (Continued) NI 6585 Connector Signal Name GPIO Out GPIO Out Enable GPIO In DDCB GLOBAL CLOCK 1 GClk_LVDS DIO 0+/ GPIO_46 GPIO_46_n GPIO_47 DIO 1+/ GPIO_62_n GPIO_63 GPIO_63_n DIO 2+/ GPIO_47_n GPIO_48 GPIO_48_n DIO 3+/ GPIO_64 GPIO_64_n GPIO_65 DIO 4+/ GPIO_43 GPIO_43_n GPIO_44 DIO 5+/ GPIO_59_n GPIO_60 GPIO_60_n DIO 6+/ GPIO_44_n GPIO_45 GPIO_45_n DIO 7+/ GPIO_61 GPIO_61_n GPIO_62 DIO 8+/ GPIO_39 GPIO_39_n GPIO_40 DIO 9+/ GPIO_54 GPIO_54_n GPIO_55 DIO 10+/ GPIO_40_n GPIO_41 GPIO_41_n DIO 11+/ GPIO_55_n GPIO_56 GPIO_56_n DIO 12+/ GPIO_36 GPIO_36_n GPIO_37 DIO 13+/ GPIO_51 GPIO_51_n GPIO_52 DIO 14+/ GPIO_37_n GPIO_38 GPIO_38_n DIO 15+/ GPIO_52_n GPIO_53 GPIO_53_n DDC CLOCK OUT+/PFI 0+ DDC CLOCK OUT /PFI 0 GPIO_49 GPIO_49_n GPIO_57 PFI 1+/ GPIO_50 GPIO_50_n GPIO_57_n PFI 2+/ GPIO_33 GPIO_33_n GPIO_58 PFI 3+/ GPIO_34 GPIO_34_n GPIO_58_n PFI 4+/ GPIO_35 GPIO_35_n GPIO_59 Power Power requirements from the FPGA module V ccoa... 315 ma, 1.1 W max V ccob... 315 ma, 1.1 W max +3.3 V... 36 ma, 0.12 W max Physical Dimensions...12.9 2.0 12.1 cm (5.1 0.8 4.7 in.) Weight...284 g (10 oz) Front panel connectors...two 68-pin VHDCI connectors National Instruments Corporation 5 NI 6585 Specifications

Environmental The NI 6585 is intended for indoor use only. Operating environment...0 C to 55 C, IEC-60068-2-1 and IEC-60068-2-2. Relative humidity range...10% to 90%, noncondensing, IEC-60068-2-56. Altitude...2,000 m at 25 C ambient temperature Pollution Degree...2 Storage environment Ambient temperature range... 20 C to 70 C, IEC-60068-2-1 and IEC-60068-2-2. Relative humidity range...5% to 95%, noncondensing, IEC-60068-2-56. Note Clean the device with a soft, non-metallic brush. Make sure that the device is completely dry and free from contaminants before returning it to service. Safety This product meets the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: EN 61326 (IEC 61326): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions AS/NZS CISPR 11: Group 1, Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions Note For the standards applied to assess the EMC of this product, refer to the Online Product Certification section. Note For EMC compliance, operate this product according to the documentation. Note For EMC compliance, operate this device with shielded cables. CE Compliance This product meets the essential requirements of applicable European Directives as follows: 2006/95/EC; Low-Voltage Directive (safety) 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Online Product Certification Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the NI and the Environment Web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee.htm. RoHS National Instruments (RoHS) National Instruments RoHS ni.com/environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) NI 6585 Specifications 6 ni.com

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. 2009 National Instruments Corporation. All rights reserved. 375858A-01 May09