www.fda.gov/cdrh/luer

Similar documents
3/26/2015. Debby Kasper, RDN, LDN Director, clinical nutrition Premier, Inc. Cathie Gosnell, RN, MS, MBA Clinical consultant Premier Safety Institute

CUESTA COLLEGE REGISTERED NURSING PROGRAM CRITICAL ELEMENTS

Enteral Feeding Misconnections. Peggi Guenter, PhD, RN, CNSN

NURSING Effective Date Title: 6/12 SCOPE OF PRACTICE FOR STUDENT NURSES AND NURSING ASSISTANTS

Guidelines for Specialized Health Care Procedures (Revision 2004)

Clinical Instructor Orientation Competency Validation Tool

INTERFACILITY TRANSFERS

Guidance for Hospitals, Nursing Homes, and Other Health Care Facilities

Information for people being discharged with a naso-gastric (NG) feeding tube

III-701 Urinary Catheterization/Bladder Irrigation Original Date: 3/1/1977 Last Review Date: 10/28/2004

TRANSPORT OF CRITICALLY ILL PATIENTS

Helping to protect you from exposure to hazardous drugs

STAY-PUT Nasojejunal Feeding Tubes. Nursing Manual/ Patient Information

Nursing Education and Research

LOS ANGELES COUNTY EMERGENCY MEDICAL SERVICES LOS ANGELES COUNTY EMT-I EXPANDED SCOPE OF PRACTICE

Nursing college, Second stage Microbiology Dr.Nada Khazal K. Hendi L14: Hospital acquired infection, nosocomial infection

X-Plain Preparing For Surgery Reference Summary

Policies & Procedures. ID Number: 1118

SARASOTA MEMORIAL HOSPITAL STANDARDS OF CARE STANDARDS OF PRACTICE

NOC: Occupation: Respiratory Therapist

Caring for a Tenckhoff Catheter

Children's Medical Services (CMS) Regional Perinatal Intensive Care Center (RPICC) Neonatal Extracorporeal Life Support (ECLS) Centers Questionnaire

02 DEPARTMENT OF PROFESSIONAL AND FINANCIAL REGULATION REGULATIONS RELATING TO ADMINISTRATION OF INTRAVENOUS THERAPY BY LICENSED NURSES

ADVANCE DIRECTIVE. Your Right to Make Health Care Decisions

3100B Clinical Training Program. 3100B HFOV VIASYS Healthcare

RGN JOY LAUDE WATFORD GENERAL HOSPITAL, ENGLAND

2015 SUMMER STUDENT NURSE EXTERNSHIP PROGRAM SKILLS CHECK LIST

Treating your abdominal aortic aneurysm by open repair (surgery)

ED PATIENT INTERFACILITY TRANSFERS

Intravenous Infusion Lines Enhancing Patient Safety During IV Therapy

The Challenge of Aero-medical Critical Care Transport. Focus on critical cases air-ambulance only

SARASOTA MEMORIAL HOSPITAL DEPARTMENT POLICY

Printed document is accurate & current for 48 hours from 09/02/10 08:41:06.

NHS FORTH VALLEY Chest Drain Insertion by Seldinger Method (Pigtail drains)

*Reflex withdrawal from a painful stimulus is NOT considered a purposeful response.

Medical Surgical Nursing Skills List

Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter

ELSO GUIDELINES FOR TRAINING AND CONTINUING EDUCATION OF ECMO SPECIALISTS

Policy and Procedure Flushing and / or Blood withdrawal Aspiration Procedure For PICC Line and Midline Catheters

Located On IV Pole Front of cart- Arrest Board

My Voice. Advance Care Plan

CADD-legacy PCA pump Model ml Cassette

BARD MEDICAL DIVISION UROLOGICAL DRAINAGE. Foley Catheter Care & Maintenance. Patient Education Guide

TITLE CLIN_216 HEMODIALYSIS/PLASMAPHERESIS PROCEDURE AND CATHETER MANAGEMENT FOR THE ADULT AND PEDIATRIC PATIENT

CONGESTIVE HEART FAILURE PATIENT TEACHING

Reducing Medical Errors for CNAs

Why is prematurity a concern?

X-Plain Subclavian Inserted Central Catheter (SICC Line) Reference Summary

Safeguarding Neonatal Nutrition

How To Improve Care For Bronchiolitis

RESPIRATORY CRITICAL CARE UNIT STUDENT INTERNSHIP SKILLS LIST Provo School District

Intro Who should read this document 2 Key Messages 2 Background 2

Surgery and cancer of the pancreas

Femoral artery bypass graft (Including femoral crossover graft)

SARASOTA MEMORIAL HOSPITAL NURSING DEPARTMENT POLICY

The Joint Commission s Patient Safety Initiatives

PROCEDURAL SEDATION/ANALGESIA NCBON Position Statement for RN Practice

X-Plain Hip Replacement Surgery - Preventing Post Op Complications Reference Summary

Diabetes Expert Witness on: Diabetic Hypoglycemia in Nursing Homes

Virginia Office of Emergency Medical Services Scope of Practice - Procedures for EMS Personnel

A PATIENT S GUIDE TO CARDIAC CATHETERIZATION

POSSIBLE NURSING DIAGNOSIS: Pain Potential for Infection / Infection Fluid volume deficit

Medications or therapeutic solutions may be injected directly into the bloodstream

NICE Pathways bring together all NICE guidance, quality standards and other NICE information on a specific topic.

INTERDISCIPLINARY CLINICAL MANUAL Policy & Procedure

a guide to understanding pierre robin sequence

NCQAC RNs Working with Medical Assistants

I.V. Administration I.V. Placement / Miscellaneous / Needle-Free Systems

Insurance options for Direct Payment Employers. London SDS Forum 2 nd Oct Copyright Premier Care Insurance 2015

Procedure for Inotrope Administration in the home

The science of medicine. The compassion to heal.

-Mary White RN, MBA, CPHRM Risk Manager, July 22, 2013

Regions Hospital Delineation of Privileges Nurse Practitioner

Freka. Enteral Feeding Tube Product Range ENTERAL NUTRITION

Patient Information. PORT-A-CATH Implantable Venous Access Systems

Patient Information and Daily Programme for Patients Having Whipple s Surgery (Pancreatico duodenectomy)

1.40 Prevention of Nosocomial Pneumonia

DELEGATION OF NURSING

National Patient Safety Goals Effective January 1, 2015

Caring Choices. For Parents of Infants Newly Diagnosed with SMA Type 1 SMA CARE SERIES

Appendix L: Accessing/Deaccessing Implanted Central Venous Access Port

PARAMEDIC TRAINING CLINICAL OBJECTIVES

Administrative Policies and Procedures for MOH hospitals /PHC Centers. TITLE: Organization & Management Of Medication Use APPLIES TO: Hospital-wide

Target groups: Paramedics, nurses, respiratory therapists, physicians, and others who manage respiratory emergencies.

State of Health Services in Connecticut Schools. Summary Highlights

Level 4 Trauma Hospital Criteria

Collaborative Practice Agreement for Nurse Practitioner Management of Patients in the Specialty of Pediatric Critical Care

ADVANCE DIRECTIVE. A LIVING WILL A Directive To Withhold Or To Provide Treatment. A Durable Power Of Attorney FOR HEALTH CARE

Guide to Delegation for Colorado School Nurses

81 First Responder Respiratory

AN ADVANCE CARE DIRECTIVE A GIFT OF PREPAREDNESS

National Clinical. Respiratory

THE EFFECTS OF NURSE EDUCATION AND CERTIFICATION ON HOSPITAL- ACQUIRED INFECTIONS

Specialty Scenarios MED-SURG

Why and how to have end-of-life discussions with your patients:

National Patient Safety Goals Effective January 1, 2015

PERIPHERALLY INSERTED CENTRAL CATHETERS (PICC) Fong So Kwan APN, Haematology unit Medical Department, QMH

PATIENT GUIDE. Understand and care for your peripherally inserted central venous catheter (PICC). MEDICAL

Peripherally Inserted Central Catheter (PICC) Benefits Long-term access - dwell time varies (can be > one year) Decreased length of stay in hospital a

Transcription:

INTRODUCTION RESOURCES ACKNOWLEDGEMENTS Hospitals and other healthcare facilities depend on a variety of catheters, tubing and syringes to deliver medications and other substances to patients through vascular, enteral, respiratory, epidural and intrathecal delivery systems. These delivery systems frequently employ fittings called Luer connectors to link various system components. The male and female components of Luer connectors join together to create secure yet detachable leak-proof connections. Multiple connections between medical devices and tubing are common in patient care. Unfortunately, because Luer connectors are ubiquitous, easy-to-use and compatible between different delivery systems, clinicians can inadvertently connect wrong systems together, causing medication or other fluids to be delivered through the wrong route. Such errors have occurred in diverse clinical settings, causing serious patient injuries and deaths. The Food and Drug Administration (FDA), The Joint Commission (TJC), the Institute for Safe Medication Practices (ISMP), the United States Pharmacopeia (USP), the ECRI Institute and others have all received reports of misconnection errors. The problem is well-known and welldocumented. Yet despite efforts on the part of FDA and other organizations to reduce misconnections through education, protocol and monitoring, the use of Luer connectors in incompatible medical delivery systems continues to create situations where dangerous misconnections can, and do, occur. To further reduce the occurrence of these misconnections, FDA is actively participating in an international effort to develop and implement standards for noninterchangeable connectors for small bore medical connectors. A joint working group established by the International Organization for Standardization (ISO) and the International Electrotechnical Commission (IEC) leads this effort to develop a series of standards for incompatible connectors used in intravascular (IV), breathing systems, enteral, urethral/urinary, cuff inflation and neuraxial applications. Once implemented, these connectors will facilitate correct connections and eliminate incompatible tubing misconnections. Until standards are completed and manufacturers design and produce products that can t be misconnected, all interested parties must continue their efforts to keep these dangerous misconnections from happening. Actions must be taken at the patient bedside, within all levels of health care organizations and throughout the channels of regulation, manufacturing and distribution of these devices in order to eradicate the serious problem of tubing misconnections, said Peter B. Angood, M.D., Vice President and Chief Patient Safety Officer for The Joint Commission (TJC). This Medical Device Safety Calendar is one of those efforts. The calendar provides a graphic depiction of misconnection cases that have occurred, coupled with recommendations from TJC on ways to pr these types of errors. We hope you ll post the Medical Device Safety Calendar as a year-long reminder to staff that these errors can occur in any clinical setting. We also urge you to use the case synopses and recommendations as ongoing training materials. To that end, we have made the photos, case studies and additional resources available, free of charge, at www.fda.gov/cdrh/luer. We encourage you to visit this web site to download and make further use of these materials. Let s continue to work together to pr these tragic errors. Daniel G. Schultz, M.D. Director, Center for Devices and Radiological Health Gallauresi, Beverly, R.N., B.S., M.P.H., Eakle, Melissa, R.N., M.B.A., M.S.N., Morrison, Audrey, R.N. Misconnections Between Medical Devices With Luer Connectors: Underrecognized but Potentially Fatal Events in Clinical Practice, Safe Practices in Patient Care. July 2007, Vol. 3, No. 2. http://www.safe-practices.org/safepractice8.pdf The Joint Commission Sentinel Event Alert. Tubing Misconnections A Persistent and Potentially Deadly Occurrence. April 3, 2006, Issue 36. http://www.jointcommission.org/sentinelevents/ SentinelEventAlert/sea_36.htm ISMP Medication Safety Alert! Problems Persist With Life-Threatening Tubing Misconnections. June 17, 2004. http://www.ismp.org/newsletters/acutecare/ articles/20040617.asp WHO Collaborating Centre for Patient Safety Solutions. Patient Safety Solutions. Avoiding Catheter and Tubing Misconnections. May 2007, Vol. 1, Solution 7. http://www.ccforpatientsafety.org/fpdf/presskit/ps- Solution7.pdf FDA Patient Safety News. More Patient Deaths from Luer Misconnections. October 2007. http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/psn/ transcript.cfm?show=68#5 Association for the Advancement of Medical Instrumentation (AAMI). ISO/IEC small bore connector new work proposal package including contact information. August 2006. http://www.aami.org/applications/ CommitteeCentral-app/Documents/SBC_PA.pdf International Organization for Standardization (ISO). ISO/CD 80369-1. Updated 2008. http://www.iso.org/ iso/iso_catalogue/catalogue_tc/catalogue_detail. htm?csnumber=45976 Medical Device Safety Calendar 2009 http://www.fda.gov/cdrh/luer The 2009 FDA Safe Medical Device Safety Calendar Working Group: Beverly Gallauresi, R.N., M.P.H. Anita Rayner, M.P.H. Alex Koustenis Barbara Richards Aron Yustein, M.D. Jay Crowley, M.S. Jill Marion Edie Seligson Nancy Pressly Susan Gardner, Ph.D. Calendar Design: Bonnie Hamalainen National Institutes of Health (NIH), Division of Medical Arts Photography: Ernie Branson National Institutes of Health (NIH), Division of Medical Arts Special Thanks to: Dorothy Brownlie, RN, CCRN Montgomery General Hospital, Olney, MD for providing technical support key Each month cites a Misconnection error based on an actual reported : Example of the misconnection error; Potential for Harm is also cited Bulleted description of the specifics pertinent to each Safety tip from The Joint Commission (TJC) to help pr recurrence Photographs show staged erroneous misconnections to illustrate the reported error. Photographs have warning labels where appropriate to reiterate the fact that they are erroneous connections.

Feeding tube erroneously connected to trach tube WARNING: Photographs depict feeding tube erroneously connected to trach tube. DO NOT DO THIS! An infant in the pediatric intensive care unit had both a feeding tube and a trach tube The feeding tube was inadvertently placed in the trach tube and milk was delivered into the infant s lungs The infant died Always trace a tube or catheter from the patient to the point of origin before connecting any new device or infusion

Epidural tubing erroneously connected to IV tubing An anesthetist and a midwife mistakenly connected an epidural set to the patient s IV tubing The epidural medication was delivered to the IV The patient died WARNING: Photographs depict epidural tubing erroneously connected to IV tubing. DO NOT DO THIS! For certain high-risk catheters (e.g., epidural, intrathecal, arterial), label the catheter and do not use catheters that have injection ports

IV tubing erroneously connected to trach cuff WARNING: Photographs depict IV tubing erroneously connected to trach cuff. DO NOT DO THIS! A child in a pediatric intensive care unit had both an IV line and a trach tube The IV tubing was inadvertently connected to the trach cuff port The IV fluid over-expanded the trach cuff to the point of breaking and continuous IV fluids entered the child s lungs The child died Emphasize the risk of tubing misconnections in orientation and training curricula

IV tubing erroneously connected to nebulizer During a nebulizer treatment, the patient s oxygen tubing fell off the nebulizer and the patient s IV tubing was inadvertently attached to the nebulizer When the patient inhaled, a moderate amount of IV fluids was aspirated into the patient s lungs The misconnection was identified by the respiratory therapist and the patient survived WARNING: Photographs depict IV tubing erroneously connected to nebulizer. DO NOT DO THIS! Do not purchase nonintravenous equipment that is equipped with connectors that can physically mate with a female luer IV line connector

Oxygen tubing erroneously connected to a needleless IV port A patient s oxygen tubing became disconnected from his nebulizer and was accidentally reattached to his IV tubing Y-site by a staff member who was completing a double shift The patient died from an air embolism, even though the connection was broken within seconds WARNING: Photographs depict oxygen tubing erroneously connected to a needleless IV port. DO NOT DO THIS! Identify and manage conditions and practices that may contribute to healthcare worker fatigue, and take appropriate action

Blood pressure tubing erroneously connected to IV catheter An ER patient had an IV heparin lock but no IV fluids had been started. The patient also had a noninvasive automatic BP cuff placed for continuous monitoring The BP cuff tubing was disconnected when the patient went to the bathroom When she returned, her spouse mistakenly connected the BP cuff tubing to the IV catheter and approximately 15 ml of air was delivered to the IV catheter The patient died from a fatal air embolus, despite resuscitation efforts WARNING: Photographs depict blood-pressure tubing erroneously connected to IV catheter. DO NOT DO THIS! Inform non-clinical staff, patients and their families that they must get help from clinical staff whenever there is a real or perceived need to connect or disconnect devices or infusions

IV tubing erroneously connected to nasal cannula A nurse s aide inadvertently connected a patient s IV tubing to the nasal oxygen cannula upon transfer to the step down unit The misconnection was not noted until 4 hours later, when the patient complained of chest tightness and difficulty breathing The patient was treated for congestive heart failure and survived WARNING: Photographs depict IV tubing erroneously connected to nasal cannula. DO NOT DO THIS! Recheck connections and trace all patient tubes and catheters to their sources upon the patient s arrival in a new setting or service as part of the handoff process. Standardize this line reconciliation process.

IV tubing erroneously connected to enteral feeding tube Moderate WARNING: Photographs depict IV tube erroneously connected to enteral feeding tube. DO NOT DO THIS! A child had both a gastric feeding tube for nutrition and an IV for medication and hydration When the child s gown was changed, a family member inadvertently attached the IV tubing to the gastric feeding tube The medication was delivered through the feeding tube into the stomach There was no patient harm since the was noted in a timely manner Inform non-clinical staff, patients and their families that they must get help from clinical staff whenever there is a real or perceived need to connect or disconnect devices or infusions

Syringe erroneously connected to trach cuff The patient had both a central line with 3 ports and a trach tube Medication intended for the central line was inadvertently injected into the trach cuff The trach cuff was damaged and the medication entered the patient s lungs A new trach tube was inserted and the patient survived WARNING: Photographs depict syringe erroneously connected to trach cuff. DO NOT DO THIS! Always trace a tube or catheter from the patient to the point of origin before connecting any new device or infusion

Foley catheter erroneously connected to NG tube Low A patient was found with her Foley catheter disconnected from its drainage bag. One end of the catheter was still in her bladder and the other end was connected to her nasogastric (NG) tube Urine was noted to be flowing into her NG tube The NG tube was connected to suction and more than 300 ml of urine drained The patient s vital signs were stable and her laboratory results were within normal limits WARNING: Photographs depict Foley catheter erroneously connected to NG tube. DO NOT DO THIS! Inform non-clinical staff, patients and their families that they must get help from clinical staff whenever there is a real or perceived need to connect or disconnect devices or infusions

Enteral feeding tube erroneously connected to ventilator in-line suction catheter A patient s feeding tube was inadvertently connected to the instillation port on the ventilator in-line suction catheter Tube feeding was delivered into the patient s lungs The patient died WARNING: Photographs depict enteral feeding tube erroneously connected to ventilator in-line suction catheter. DO NOT DO THIS! Emphasize the risk of tubing misconnections in orientation and training curricula

Success story! These photos show that PAS pump tubing is now NOT CAPABLE of connecting to IV vascular access devices. can t connect Pulsatile anti-embolism stocking erroneously connected to IV heparin lock A patient admitted for stroke had a pulsatile anti-embolism stocking (PAS) on the left lower extremity and an IV heparin lock in the right ankle The patient was alert and oriented on admission but shortly after was found unresponsive and cyanotic The PAS pump tubing was found connected to the IV heparin lock in the patient s right ankle The patient died of a massive air embolus can t connect Manufacturers should implement designed incompatibility as appropriate, to pr dangerous misconnections of tubes and catheters