NEC SigmaSystemCenter 3.0 highlights



Similar documents
VMware vsphere-6.0 Administration Training

NEC SigmaSystemCenter Integrated Virtualization Platform Management Software

Veeam ONE What s New in v9?

In addition to their professional experience, students who attend this training should have technical knowledge in the following areas.

VMware vsphere 5.1 Advanced Administration

VMWARE VSPHERE 5.0 WITH ESXI AND VCENTER

Security. Environments. Dave Shackleford. John Wiley &. Sons, Inc. s j}! '**»* t i j. l:i. in: i««;

VMware vsphere 5.0 Boot Camp

Set Up a VM-Series Firewall on an ESXi Server

Implementing Enhanced Secure Multi-tenancy Solutions (IESMT)

RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS: COMPETITIVE FEATURES

7 Ways OpenStack Enables Automation & Agility for KVM Environments

Remote PC Guide Series - Volume 1

VMware vsphere Design. 2nd Edition

Implementing and Managing Windows Server 2008 Hyper-V

vsphere Replication for Disaster Recovery to Cloud

Set Up a VM-Series Firewall on an ESXi Server

Table of Contents. vsphere 4 Suite 24. Chapter Format and Conventions 10. Why You Need Virtualization 15 Types. Why vsphere. Onward, Through the Fog!

TGL VMware Presentation. Guangzhou Macau Hong Kong Shanghai Beijing

VMware vsphere 4.1 with ESXi and vcenter

User Guide for VMware Adapter for SAP LVM VERSION 1.2

Hyper-V vs ESX at the datacenter

Citrix Lab Manager 3.6 SP 2 Quick Start Guide

Virtualization Technologies. Embrace the new world of healthcare

Index C, D. Background Intelligent Transfer Service (BITS), 174, 191

Overview Customer Login Main Page VM Management Creation... 4 Editing a Virtual Machine... 6

VMware vsphere: Fast Track [V5.0]

Enterprise Cloud VM Image Import User Guide. Version 1.0

Silver Peak Virtual Appliances

VMware vsphere: Install, Configure, Manage [V5.0]

Cloud Optimize Your IT

Server-Virtualisierung mit Windows Server Hyper-V und System Center MOC 20409

Aerohive Networks Inc. Free Bonjour Gateway FAQ

Install Guide for JunosV Wireless LAN Controller

How To Install Vsphere On An Ecx 4 On A Hyperconverged Powerline On A Microsoft Vspheon Vsphee 4 On An Ubuntu Vspheron V2.2.5 On A Powerline

PassTest. Bessere Qualität, bessere Dienstleistungen!

Expert Reference Series of White Papers. Visions of My Datacenter Virtualized

10215A Implementing and Managing Microsoft Server Virtualization

Network Troubleshooting & Configuration in vsphere VMware Inc. All rights reserved

Migrating Control System Servers to Virtual Machines

Khóa học dành cho các kỹ sư hệ thống, quản trị hệ thống, kỹ sư vận hành cho các hệ thống ảo hóa ESXi, ESX và vcenter Server

E-SPIN's Virtualization Management, System Administration Technical Training with VMware vsphere Enterprise (7 Day)

6422: Implementing and Managing Windows Server 2008 Hyper-V (3 Days)

Management of VMware ESXi. on HP ProLiant Servers

Comprehensive Monitoring of VMware vsphere ESX & ESXi Environments

Veeam Study Webinar Server Virtualization with Windows Server Hyper-V and System Center. Orin

Architecting and Building a Secure and Compliant Virtual Infrastructure and Private Cloud

Microsoft Exchange Solutions on VMware

Vmware VSphere 6.0 Private Cloud Administration

About the VM-Series Firewall

To join the audio portion of this webcast: meeting code

VM-Series Firewall Deployment Tech Note PAN-OS 5.0

Rally Installation Guide

Citrix CloudPlatform (powered by Apache CloudStack) Version 4.5 Administration Guide

Evaluation of Multi-Hypervisor Management with HotLink SuperVISOR

Ixia Phantom vtap. Overview. Virtual Taps Phantom Monitoring Solution DATA SHEET

Directions for VMware Ready Testing for Application Software

How To Make A Virtual Machine Aware Of A Network On A Physical Server

FOR SERVERS 2.2: FEATURE matrix

Implementing and Managing Microsoft Server Virtualization

What s New with VMware Virtual Infrastructure

Implementing and Troubleshooting the Cisco Cloud Infrastructure **Part of CCNP Cloud Certification Track**

V-locity 3 Installation Guide

Bosch Video Management System High availability with VMware

Virtual SAN Design and Deployment Guide

Installing and Using the vnios Trial

VIRTUALIZATION 101. Brainstorm Conference 2013 PRESENTER INTRODUCTIONS

Altor Virtual Network Security Analyzer v1.0 Installation Guide

How to Configure an Initial Installation of the VMware ESXi Hypervisor

vsphere Private Cloud RAZR s Edge Virtualization and Private Cloud Administration

Paragon Protect & Restore

How To Make A Cloud Based System A Successful Business Model

HP + Veeam: Fast VMware Recovery from SAN Snapshots

Uila Management and Analytics System Installation and Administration Guide

Building a Penetration Testing Virtual Computer Laboratory

Introduction to VMware EVO: RAIL. White Paper

Bosch Video Management System High Availability with Hyper-V

SPEED your path to virtualization.

Frequently Asked Questions: EMC UnityVSA

Citrix CloudPlatform (powered by Apache CloudStack) Version Administration Guide

Drobo How-To Guide. Use a Drobo iscsi Array as a Target for Veeam Backups

Thinspace deskcloud. Quick Start Guide

Foundations and Concepts

ArCycle vmbackup. for VMware/Hyper-V. User Guide

Vmware Training. Introduction

MODULE 3 VIRTUALIZED DATA CENTER COMPUTE

Red Hat enterprise virtualization 3.0 feature comparison

VMware vsphere: [V5.5] Admin Training

PHD Virtual Backup for Hyper-V

Backup and Recovery Best Practices With CommVault Simpana Software

Provisioning Server Service Template

VMware vsphere 4.1. Pricing, Packaging and Licensing Overview. E f f e c t i v e A u g u s t 1, W H I T E P A P E R

Advanced Server Virtualization: Vmware and Microsoft Platforms in the Virtual Data Center

ClearPass Policy Manager 6.3

Barracuda Backup Vx. Virtual Appliance Deployment. White Paper

CloudPlatform (powered by Apache CloudStack) Version Administrator's Guide

M6422A Implementing and Managing Windows Server 2008 Hyper-V

CloudPlatform (powered by Apache CloudStack) Version 4.2 Administrator's Guide

JOB ORIENTED VMWARE TRAINING INSTITUTE IN CHENNAI

Installing and Configuring vcenter Multi-Hypervisor Manager

Transcription:

NEC SigmaSystemCenter 3.0 highlights NEC Corporation 2nd IT Software Division IT Network Global Solutions Division Sept. 2011

NEC SigmaSystemCenter 3.0 highlights Cloud Management Multitenancy Resource Pool Role Management Life Cycle Management Service Portal Logical Network/IP Address Pool Expanding supported hypervisor Supporting distributed switch High-speed Scale-out VM Optimized Creation Machine Profile/Host Profile Enhanced Datastore Management VM Optimized Placement Rule Simple configuration of physical computers and virtual hosts Enhanced Performance Monitoring Agentless Monitoring Enhanced Console Access Function DeploymentManager 6.0 and ESMPRO/ServerManager Ver.5 Enhanced SIGMABLADE Integration Page 2

Cloud Management Multitenancy Resource Pool Role Management Life Cycle Management Service Portal Logical Network/IP Address Pool Virtualization management is enhanced in SSC(*1)3.0, which realize infrastructure management in cloud environment. These feature also helps the customer who has not deployed cloud system, realizing efficient implementation and operation. *1 Abbreviation of NEC SigmaSystemCenter Page 3

How clouds operate with SSC Users Tenant A Resource reservation and VM creation Maintenance and troubleshooting by users The VM and resources of other tenants cannot be accessed Service portal Configu ration Tenant administrator Sub Resource Pool IP/VLAN pool Users Tenant B Resource reservation and VM creation Service portal Configu ration Tenant administrator Image library Sub Resource Pool IP/VLAN pool Tenant creation/ Creation of user for tenant administrator/ Allocation of sub resource pool System administrator Resource pool Resource pool creation/extraction from the sub resource pool Servers Page 4 NEC Corporation 2011 Storage devices Maintenance and troubleshooting by users Network devices Images Image library

Cloud Management - Multitenancy Improve resource utilization by sharing resources between multiple tenants The resources managed by SSC are shared among the tenants. Because you do not need to assign specific servers, storage devices, or switches to each tenant, the resources in the system can be used efficiently. This is explained in further detail in the resource pool section on the next slide. Security must be a consideration while sharing resources. Users from other tenants should not be able to view resource usage or control a guest. SSC offers protection against this security issue. More information is provided in the section on role management. Page 5

Cloud Management Resource Pool Managing resources in a large-scale environment is simple In a resource pool, management is simplified because resources are managed as virtual resources such as virtual CPU and virtual memory which compose virtual machine. Resources can be managed at the tenant level A portion of the resources are extract to form a sub resource pool that is assigned to a tenant for use. The efficient use of resources is possible through the sharing of one resource pool among multiple tenants. Visualize resource usage Visualize the usage of a resource pool to view the usage of resource pools and sub resource pools. This makes possible the prediction of shortages and planned increases of resources. Page 6

Cloud Management - Resource Pool Conceptual diagram Extract sub resource pools Create resource pool Tenant A Sub resource pool A Servers Storage devices Physical resources Resource pool Tenant B Resource pool usage status Sub resource pool B Page 7 NEC Corporation 2011

Cloud Management Role Management Your system is secure because users from other tenants cannot access the guest or resources. Manage tenant users through a tenant administrator You can limit the resources to which each user has access by specifying roles to each tenant user. Page 8

Cloud Management Life Cycle Management Manage usage history The strict management of resource expiration dates is important. It is especially so for the tenant lending service, in which charges are based on the beginning and end date of usage and how much the resource was used. Therefore, managing the resource life cycle and understanding its usage history is necessary. You can also keep a track on the history of a guest powering on and shutting down. Manage a history of configuration changes You can manage a history of changes made to the guest s. Make groups through smart grouping(*) Service start date Service end date The number of days remaining until service start date The number of days elapsed sine the service end date (*)Smart groups can be specified through a command-line interface. Page 9

Cloud Management Service Portal Making the SSC screen available to end users There are instances in which a guest must be restarted because a guest sometimes stalls. A service portal is offered in which users can solve such problems themselves without going through a tenant administrator. Log in as a tenant user Tenant users Create a guest Start or restart the guest Etc. Portal Page 10

Cloud Management Logical Network/IP Address Pool Defines logical networks composed of tenant VLAN IDs and guest IP address pools. You can centrally manage which VLAN ID and IP address are pooled with which tenant. Automatically specifies linked VLANs and IP addresses when a virtual host or guest specified by the logical network starts operation. The logical network settings can be made available for reference to only certain tenants in order to ensure security between tenants. Page 11

Expanding supported hypervisor KVM is now supported in addition to VMware, XenServer, and Hyper-V RHEL6.0 KVM is supported. XenServer Hyper-V KVM VMware Page 12

Supporting distributed switch Support VMware vnetwork Standard Switch / Distributed Switch Creating port group (VLAN) from SSC is possible and port group is assigned dynamically in guest creation. vds can make private VLAN which realize flexible network design by Network isolation is important in security point of view for multi tenant environment in cloud. Page 13

High-speed Scale-out Guest high-speed scale out by Differential Clone Differential Clone is an option feature and must be purchased separately VM01 Master VM System disk Reference Reference Reference Differential disk VM02 Differential disk Extended disk Extended disk User-specific data sent to extended disk space VM03 Differential disk Extended disk Dramatically reduce VM creation time by Differential Clone. The more guest you create, the more effective you receive. (Around 5 minutes to create 50VM.) Disk usage reduction is also possible using this technology. Page 14

High-speed Scale-out Differential Clone also brings benefits from an operations perspective. Reconstruct lies a patch to the master VM and rapidly updates every VM Patch Master VM System disk after patch application Revert Changing the reference VM01 VM02 VM01 Extended disk Extended disk The increased differencing disks are discarded and the state at the time of creation is restored. Suitable for operations such as help desks in which returning to the initial state occurs at regular intervals Discard Extended disk space is retained Master VM System disk Disk difference VM02 Discard Disk difference Page 15

High-speed Scale-out Reduce time to apply individual information Reduce time to set up Windows Vista, Windows 7, Windows Server 2008, Windows Server 2008 R2 using disk duplication function, which will help to improve gust creation process in Hyper-V, XenServer. Page 16

VM Optimized Creation Automatic selection of the best host and storage device when creating a guest Selects the most suitable host and balances CPU and memory loads Selects the most suitable storage device and balances storage consumption Selects a host Server A Server B Server C Management server Selects a storage device Storage Storage Creates guest on servers to distribute the host and storage device loads. Page 17

Machine Profile/Host Profile Support host profile in addition to machine profile and those profile can be referred from specific tenant. Machine profile Definition of machine specification such as virtual CPU, virtual memory. Created guest s with different of specification using the same template. Hardware spec information have been separated from templates. Host profile Guest is created based on machine profile specification. Possible to reconfigure by changing machine profile Definition of setting information. User name/password, Workgroup/Domain setting. DNS/WINS Host Profile setting is used when a machine is activated in SSC. Page 18

Machine Profile/Host Profile Creating guest s with different specifications using the same template is possible by machine profile. CPU: 2 Memory: 4 GB NIC: eth0, eth1 Disk: System - 10 GB Extended - 20 GB Template VM creation VM creation Batch modification of guest configurations VM01 VM02 CPU: 1 Memory: 2 GB NIC: eth0 Disk: System - 10 GB Extended - 10 GB CPU: 4 Memory: 8 GB NIC: eth0, eth1, eth2 Disk: System - 10 GB Extended - 120 GB CPU: 1 Memory: 2 GB NIC: eth0 Disk: System - 10 GB Extended - none VM01 VM02 VM03 Change Computer profile CPU: 2 Memory: 4 GB NIC: eth0, eth1 Disk: System - 10 GB Extended - 20 GB Reflection VM01 VM02 VM03 Page 19

Enhanced Datastore Management Datastore configuration Users can specify priority levels and exceptions for datastores. The maximum usage (%) and the number of VMs that can be created can also be specified for each datastore. Specifying a datastore through attributes Users can specify a tag attribute such as gold and silver to datastores. By specifying tags to datastores in a computer profile, the guest is created in the most suitable datastore with the specified attribute tag. Guest creation CPU: 2 Memory: 4 GB NIC: eth0, eth1 Disk: System - 10GB datastore: gold tag Management server datastore selection Tag: gold Tag: gold Tag: gold Tag: silver Tag: silver Page 20

VM Optimized Placement Rule In addition to VM-VMS(Pin) rule VM-VM(EQ) rule is also supported. VM-VMS(Pin) rule relates a specific virtual machine to a specific host. VM-VM(EQ) rule relates a specific virtual machine to another specific virtual machine. Runs related multiple guest s on the same host. Realize reduction of service response and performance degradation. Live migration or failover Operational group 2 Operational group 2 Operational group 1 01 02 Web01 Web02 02 Web02 Host01 Host02 Host03 Page 21

Simple configuration of physical computers and virtual hosts Control of network devices connected to physical computers and virtual hosts (such as switches and load balancers) and storage devices can be implemented from the UI of SSC. VLANs (including tagged VLANs) and storage devices that have been set to the group are automatically assigned when starting operations on a computer. Users can centrally configure and manage systems without manually specifying each server, network, and storage device. virtual switch and virtual distributed switch, and Hypervirtual network can also be configured. When changing configuration, you can modify system configuration settings (such as additional tagged VLAN or storage settings) and then these changes can be reflected to the machines running in a group at once. Page 22

Enhanced Performance Monitoring Integrate SystemMonitor console to SSC view. Power consumption monitoring Page 23

Agentless Monitoring Ping monitoring/port monitoring PET report reception Monitor server not supported by ESMPRO ServerAgent. ESXi and ESX in vsphere5 A certain level of failure detection is possible by monitoring failure via vcenter. XenServer Page 24

Enhanced Console Access Function Console access to VM Hyper-V, XenServer, KVM is also supported in addition to VMware. Remote access to serial console on physical machine. The serial console uses IPMI Serial Over Lan (SOL) and opens a SOL session to BMC of a machine to communicate with. Access to a console using utilities such as Remote Desktop or a dedicated tool is not needed. All machines can be operated from a management server. The BI screen can be used before staring up the. It is effective for failure analysis. Page 25

DeploymentManager 6.0 and ESMPRO/ServerManager 5.0 DeploymentManager 6.0 Web UI renewal Improve operation and realize to manage images centrally Backup/Restore can be executed though SSC without scenario setting. ESMPRO/ServerManager 5.0 Web UI renewal Integrate server management function for In-Band/Out-of-Band Page 26

Enhanced SIGMABLADE Integration Improve N+1 operation by controlling vio Control function, IO Shared Switch in SIGMABLADE. Replace Path switching vio Control function is a technology that virtualizes MAC addresses, WWN and UUID. The information configured by vio Control function (such as virtual MAC, virtual WWN, and virtual UUID) can be controlled from SSC. If a failure should occur so the spare machine can be activated with the same setting as the failed machine. Page 27