Online Chemistry Course (OLCC) Chemical Safety: Protecting Ourselves And Our Environment



Similar documents
Compressed Gas Cylinder Storage and Handling Guide

Standard Operating Procedure

Mechanical Systems Competency 1.20

Safe Operating Procedure

STORAGE AND HANDLING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

Explosion Prevention

CHEMICAL LABORATORY SAFETY

Flammable and Combustible Liquids. Slide 1 (of 23)

Notes. Material 1. Appropriate Flammable Liquids

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Flammable Liquids 29 CFR

BUSINESS LICENSE (2014) CHARTER TOWNSHIP OF FLINT 1490 S. DYE ROAD, FLINT Ml (810) OR FAX (810)

SECTION FC 2706 NON-PRODUCTION CHEMICAL LABORATORIES

Sample Written Program. For. Flammable Liquids

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

Static Spark Ignites Flammable Liquid during Portable Tank Filling Operation

Installation Instructions for Alarm Module Kit A043F059

FDNY C14 Certificate of Fitness Quiz

Factory owners must ensure the boiler is:

Presented by: Rich Perry Marsh Risk Consulting

UCLA - Compressed Gas Cylinder Storage and Handling

FLAMMABLE AND COMBUSTIBLE LIQUIDS

9/15/2011. Presented by: Jason Reason, CIH, CSP, CHMM Senior Industrial Hygienist Indiana Occupational Safety and Health Administration

Division of Public Health Administrative Manual

SAFETY DATA SHEET Glen-Pak TM DNA purification cartridge (for use with disposable syringes) xx

OSHA Office of Training and Education 1

ADMINISTRATIVE SERVICES MANUAL

Making sense of Intrinsic Safety and Intrinsically Safe Tools

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Hazardous Waste Procedures. Faculty of Science University of Ottawa

HAZARD COMMUNICATION & THE GLOBAL HARMONIZING SYSTEM EMPLOYEE TRAINING

Hazardous Substance Class Definitions & Labels

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools

Laboratory Safety Guideline Electrical Safety

BP WIND ENERGY POLICIES AND PROCEDURES

Hazard Communication Policy

APPLIED PETROCHEMICAL RESEARCH

CHAPTER 12 Occupational Safety & Health and Environmental Protection Programs

Fig. 2 Option 1 Integrated Design using Physical Separation. Fig. 1 Standard Modular Process Skid Design Concept

Alaska. Occupational Safety and Health Standards. quick guide to. hazard communication for general industry. What you should know and not a word more!

ARE YOU IN COMPLIANCE WITH THE OSHA COMBUSTIBLE DUST DIRECTIVE? Revised March 18, 2009

Hazardous materials can be silent killers. Almost every household and workplace has varying amounts of chemicals that, if spilled or combined, will

Code Compliance Guideline: Swimming Pool Chemicals

Standard Operating Procedure: Flammable Liquids

Hazardous Waste Determination and Management Plan

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

If you have any questions about how to safely undertake a task or project, ask your supervisor before you begin.

HAZARD COMMUNICATION PROGRAM. Raul F. Garcia-Casariego CSP, CHMM Industrial Hygienist

SOLVENT CLEANER MSDS Page 1 of 5 SAFETY DATA SHEET. (To comply with OSHA s Hazard Communication Standard 29CFR /ANSI z400.

A Guide to the European Standard for Safety Storage Cabinets (BS EN )

Preventing Overheated Boiler Incidents

MATERIAL SAFETY DATA SHEET. PRODUCT NAME: BOSTON AEROSOL ENAMEL PAINT PRODUCT CODE: BT dependant on colour

AIR-CONDITIONER SPLIT TYPE

On-Site Risk Management Audit Checklist for Program Level 3 Process

Work Health and Safety Regulations: Classification and labelling for workplace hazardous chemicals

ENVIRONMENTAL HEALTH AND SAFETY HAZARDOUS MATERIALS MANAGEMENT PLAN

Sterilization methods and equipment Lab 1-2

Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants

MATERIAL SAFETY DATA SHEET DATE: 2009, revised July 2011 PRODUCT NAME: BOSTON BRAKE & PARTS CLEANER PRODUCT CODE: 78200

Laboratory Specific Standard Operating Procedures Mandated by the Settlement Agreement

INTERNATIONAL STANDARD

WHMIS After GHS: Preparing for Change. Canadian Centre for Occupational Health and Safety

SL280UHV SERIES GAS FURNACE WARNING

Chapter XIV OCCUPATIONAL SAFETY AND HEALTH ACT. The Occupational Safety and Health Act (the Act ), 29 U.S.C. 651, et seq., is

LCT 1025 (08/08) Copyright 2008 Harleysville Mutual Insurance Company Page 1 of 5 All rights reserved

**** MATERIAL SAFETY DATA SHEET **** STABIL Fuel Stabilizer **** SECTION 1 - CHEMICAL PRODUCT AND MANUFACTURER IDENTIFICATION ****

Your Boiler Room: A Time Bomb?

MATERIAL SAFETY DATA SHEET PRODUCT NAME:

Gas Standards and Safety. Guidance Note GAS INSTALLATIONS SUPPLIED FROM BIOGAS FACILITIES - ACCEPTANCE REQUIREMENTS GAS ACT 2000

Graphene Water Dispersion

Uline NFPA. SECTION 1 : CHEMICAL PRODUCT AND COMPANY IDENTIFICATION MSDS Name: Collapsible Bulk Containers

Combustible dust. How to use this guide. Combustible Dust

Boiler Preparation, Start-Up and Shutdown

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

Chemical Reducing Solution CRS

Material Safety Data Sheet

Hazardous Waste Management Procedures

Basic Laboratory Safety

TEXAS TECH UNIVERSITY HAZARDOUS WASTE PROGRAM DEPARTMENT OF ENVIRONMENTAL HEALTH AND SAFETY

Material Safety Data Sheet

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

MATERIAL SAFETY DATA SHEET

Outline. Background. NFPA 820 Applicability to Wastewater Treatment Facilities. Hazardous Area Classifications. Treatment Plant Area Classifications

CeramClean II Aluminum Safe

WINDEX ORIGINAL GLASS CLEANER

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS 527 CMR 14.00: FLAMMABLE AND COMBUSTIBLE LIQUIDS, FLAMMABLE SOLIDS OR FLAMMABLE GASES

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

3053 Electrical Safety Training Program Course Outline

Continuous flow direct water heating for potable hot water

Propane Fuel. Material Safety Data Sheet

Flammable liquid classes: Combustible Liquid Classes. Class IC. Class II. Class IB F.P. below 22.8 C (73 F), boiling point at or above 37.

Hazardous materials can be silent killers. Almost every household and workplace has varying amounts of chemicals that, if spilled or combined, will

MILESTONE. MicroSYNTH. Microwave Synthesis Labstation

Safe Work in Confined Spaces

Safety Data Sheet for Whole Grain

TABLE OF CONTENT

Flammable Liquids Storage

MATERIAL SAFETY DATA SHEET

Transcription:

Online Chemistry Course (OLCC) Chemical Safety: Protecting Ourselves And Our Environment Paper: 2.b Discussion: September 12 18, 2004 Title: Safety Issues Related to Microwave-Enhanced Chemistry Author: Affiliation:, Morgantown WV Posted: 10/29/2004 Website: http://science.widener.edu/svb/olcc_safety/index.html

SAFETY ISSUES RELATED TO MICROWAVE-ENHANCED CHEMISTRY Eberly College of Arts and Sciences 26506-6045 (304) 293-2729 bfoster@wvu.edu INTRODUCTION Why do chemists use microwave ovens in their laboratories? Chemistry was defined in Dr. Johnson s Dictionary of 1775 as an art whereby sensible bodies contained in vessels are so changed by means of certain instruments, and principally fire, that their several powers and virtues are thereby discovered, with a view to philosophy or medicine. 1 Thankfully, nowadays, we do not use fire in the strictest sense to heat chemicals in the laboratory to obtain our desired results. Scientists use various methods to stimulate chemical reactions that would otherwise not take place under ambient conditions. Many researchers have discovered that the process of microwave heating of chemicals can be more energy efficient than conventional heating methods, such as oil baths, steam baths, heating mantles, and hot plates, which use convection and conduction principles. When liquids or solids are heated in a microwave oven, the microwaves pass through the transparent reaction vessel and are absorbed by the reaction mixture, thus transforming electromagnetic energy into heat, which drives the chemical reaction. Accelerated reaction rates and higher yields are desired results that can be achieved by using microwaves. When using microwaves to heat reactions, less time is required to achieve the desire result (i.e., oxidations, esterifications, hydrolyses, Diels-Alder reactions, ether preparations). However, these same characteristics often make the reactions more difficult to control and reproduce. At home, consumers regularly use microwave ovens to warm snacks or cook meals because they are quick and convenient to use, but domestic-grade microwave ovens should never be used to heat chemicals in a laboratory. They do not possess the inherent safety features that are necessary to avoid accidents in the laboratory. To avoid worker injury, costly fires, explosions, and facilities damage, researchers should purchase laboratory-grade microwave ovens with built-in safety features for their experimental work involving the heating of chemicals. 1

SAFETY FEATURES IN LABORATORY-GRADE MICROWAVE OVENS What standard safety features should be included in a laboratory-grade microwave oven to protect the laboratory worker? When purchasing a laboratory-grade microwave oven, one should ensure that the oven includes the following safety features: A ventilation system that protects the laboratory worker by preventing exposure to flammable and toxic materials. A solvent sensor that detects the presence of significant amounts of flammable organic solvents in the microwave cavity and can be designed to automatically shut down the microwave before the lower explosive limit (LEL) concentration in air is attained. Solvent sensors can also be located in the exhaust system. An electric interlock system that is designed to prevent the operation of the instrument in the event of fan failure or obstruction of the venting system. A feedback control system that utilizes a temperature probe to prevent overheating of samples by controlling the temperature of the solution based on reaction profiles and standard methods. A rotator and wave stirrer to minimize temperature variations within the cavity. An adjustable-speed air pump that can produce even distribution of temperature. A shorter cycle time selector to provide more precise temperature control. The complete isolation of the reaction cavity from all electronic components to prevent corrosion of control and safety circuits and to prevent electrical ignition of solvents. The most common sources of ignition in the laboratory are gas flames and heating elements. A pressure release mechanism for laboratory microwave vessels that is designed to protect the unit and the laboratory workers in the event of a complete failure of the vessel. The cavity should be grounded, unable to float electrically, and coated with a non-conducting material (i.e., Teflon) to minimize the potential of highenergy discharge. The microwave oven door should be able to withstand an event equivalent to the explosion of 1g TNT. These built-in safety features generally translate into higher list prices for laboratory-grade equipment. The typical list price for a 1200W, 1.6 cu.ft. domestic-grade microwave oven is approximately $120. The typical list price for a laboratory-grade microwave oven that is comparable in size can begin at $5000. 2 APPLICABLE CODES 2

Are there any federal codes or standards that apply to the use of microwave ovens in the laboratory? The National Fire Protection Association (NFPA) NFPA 45 - Standard on Fire Protection for Laboratories Using Chemicals, 2000 Edition was designed to control hazards and protect personnel from the toxic, corrosive, or other harmful effects of chemicals to which personnel might be exposed as a result of fire or explosion (1.2.2) 3 The stated purpose of NFPA 45 is to provide basic requirements for the protection of life and property through prevention and control of fires and explosions involving the use of chemicals in laboratory-scale operations (1.2.1). Section 9.1.2.1 (Heating Operations) states, All heating of flammable or combustible liquids shall be conducted so as to minimize fire hazards. The standard advises that flammable or combustible vapors that evolve during drying operations should be vented to avoid ignition (Section 9.1.6 (Other Operations). Section 9.2.3.4 (Heating Equipment) states Laboratory heating equipment such as ovens, furnaces, environmental chambers, and other heated enclosures shall not be used to heat, store, or test flammable or combustible liquids or aerosols containing flammable gases unless the equipment is designed or modified to prevent internal explosion. Microwave ovens that are not explosion-proof quality do not conform to NFPA 45 and are considered to be ignition sources, along with other less obvious electrical sources such as refrigerators, stirrer motors, and heat-guns. Most standard operating procedures for microwave ovens and Material Safety Data Sheets (MSDS) for flammable liquids clearly state that flammable liquids should not be heated up or produced in microwave ovens. The OSHA Laboratory Standard, 29 CFR 1910.1450, Occupational Exposure to Hazardous Chemicals in Laboratories, defines a flammable liquid as a liquid having a flash point below 100 F (37.8 C), except any mixture having components with flash points of 100 F (37.8 C) or higher, the total of which make up 99 percent or more of the total volume of the mixture. 4 The Laboratory Standard defines an explosive chemical as a chemical that causes a sudden, almost instantaneous release of pressure, gas, and heat when subjected to sudden shock, pressure, or high temperature. According to the August 8, 2002 OSHA Standard Interpretation, Applicable OSHA standards and safety considerations for microwave device use in a laboratory, possible hazards that should be considered when using a microwave oven in a laboratory setting include: o Microwave radiation may leak from damaged door seals, hinges, or latch, or because someone defeats the interlock system. o When flammable or combustible materials are heated and the temperature nears the flash point, fire or explosion is more likely. (The superheated state is unstable and it can very rapidly convert to a gaseous state at the boiling point, retaining a substantial quantity of vapor. If the flash point of the liquid is reached, ignition may occur.) 3

o When flammable liquids are heated in a closed area, the vapor concentration increases and may exceed the lower flammable limit. o The electrical wiring can provide an ignition source. o The electrical wiring could be damaged or not installed correctly. o When hazardous chemicals are heated in a closed device, employees will be exposed to higher than usual vapor concentrations when the device is opened. o The microwave radiation or the heating process may act on chemicals to produce more hazardous chemical by-products. 5 Additionally, synthetic reactions in which elemental metals are the resulting product may cause electrical arcing, a sustained luminous electric discharge across a gap, which occurs at high temperatures. 6 The resulting arcing becomes an excellent ignition source and can damage the oven, which can lead to microwave leakage. An accident which occurred at an environmental laboratory involved the rapid evolution of a gas from a microwave digestion vessel during the microwave digestion of two dissimilar samples of unknown composition. The microwave oven door was blown off of its hinges and was transformed into a missile, which landed approximately 15 feet from its origin, striking a lab bench during its sojourn. It should be noted that similar accidents have occurred in the United States in an analytical laboratory at a Fortune 500 company, a chemical plant laboratory, a pharmaceutical laboratory, a medical laboratory, and a government laboratory. 7 GREEN CHEMISTRY How do the principles of Green Chemistry apply to microwave-enhanced chemistry? According to the U.S. Environmental Protection Agency 12 Principles of Green Chemistry, the Twelfth Principle states: Minimize the potential for accidents: Design chemicals and their forms (solid, liquid, or gas) to minimize the potential for chemical accidents including explosions, fires, and releases to the environment. 8 Although some researchers believe that the concepts of Green Chemistry can be applied to microwave heating techniques, these concepts do not apply when using flammable liquids in microwave ovens. The use of flammable liquids in domestic-grade microwave ovens has resulted in explosions and fires in the laboratory. 9 Using a domestic-grade microwave oven to conduct experimental work involving flammable liquids violates the Twelfth Principle. An energy savings benefit does not justify the potential for injury and property loss when using a domestic-grade microwave oven. 4

CONCLUSIONS The emerging field of microwave-enhanced chemistry is exciting and full of promise for the researcher. Microwave ovens allow the chemist to produce higher yields of the desired product in less time. Experimental work that involves heating flammable liquids should never be performed in a domestic-grade microwave oven, which lacks the safety features that are necessary to avoid injuries, explosions, and fires. To avoid injuries and property loss, researchers must purchase and utilize laboratory-grade microwave ovens that possess requisite safety features. 5

REFERENCES 1 D. Michael P. Mingos, D.R. Baghurst. Microwave Enhanced Chemistry: Fundamentals, Sample Preparation, and Applications, H. M. Kingston, Editor, Chapter 1: Applications of Microwave Dielectric Heating Effects to Synthetic Problems in Chemistry, American Chemical Society: Washington, D.C., 1997. 2 M.E. Cournoyer, B.L. Foster. The Use of Microwave Ovens with Flammable Liquids, 2003. 3 National Fire Protection Association, NFPA 45: Standard on Fire Protection for Laboratories Using Chemicals; Quincy, MA, 2000 edition. 4 Occupational Safety and Health Administration, Occupational Exposure to Hazardous Chemicals in Laboratories; 29 CFR; Part 1910.1450, 1990. 5 U.S. Department of Labor, OSHA Standard Interpretation, Response to Dr. Gary Login, 08/08/2002, Applicable OSHA standards and safety considerations for microwave device use in a laboratory. 6 Rieke, Rueben D.; Sell, Matthew S.; Klein, Walter R.; Chen, Tian-an; Brown, Jeffrey D.; Hanson, Mark V. Rieke metals: highly reactive metal powders prepared by alkali metal reduction of metal salts, Active Metals (1996), 1-59. 7 H. M. (Skip) Kingston, P.J. Walter, W.G. Englehart, and P.J. Parsons, Laboratory Microwave Safety, Chapter 16: Microwave Enhanced Chemistry: Fundamentals, Sample Preparation, and Applications, Chapter 16 Microwave Laboratory Safety, American Chemical Society: Washington, D.C., 1997, http://www.sampleprep.duq.edu/dir/mwavechap16/mwave.htm#appendixc 8 U.S. Environmental Protection Agency Green Chemistry Principles, http://www.epa.gov/greenchemistry/principles.html (accessed October 2004) 9 D.M.P. Mingos, D.R. Baghurst, Chem. Soc. Rev. 1991, 20.1; C.R. Strauss, R.W. Trainor, Austr. J. Chem. 1995, 48, 1665. 6