AN ALTERNATIVE REINFORCMENT METHOD FOR MANDIBULAR IMPLANT RETAINED OVERDENTURES WITH E-GLASS FIBERS: A CASE REPORT



Similar documents
Implant Retained Overdenture Improves the Retention and Stability by Using a Locator System in a Mandibular Edentulous patient: A

The Transition from Teeth to Implants and the Use of Post-ceramic Soldering

Flexible dentures an alternate for rigid dentures? Volume 1 Issue 1

Retention of maxillary implant overdenture bars of different designs

Ridge Reconstruction for Implant Placement

AN INVESTIGATION OF FRACTURE LOADS OF ACRYLIC BASE PLATES REINFORCED, NON-REINFORCED AND PREPARED IN DIFFERENT PALATAL SHAPES

ADA Insurance Codes for Laboratory Procedures:

IMPLANT DENTISTRY EXAM BANK

Resin based materials in prosthetic dentistry. Mercedes Linninger DDS Department of prosthodontics

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

Improving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures

INTRODUCTION. most popular stud attachment available to the dental profession to increase the retention of implant complete

SCD Case Study. Treatment Considerations for Implant Rehabilitation

FABRICATION OF AN INDIVIDUAL EXTRA-ORAL FACIAL SHIELD TO PREVENT DENTAL TRAUMA IN CONTACT SPORTS: A CLINICAL REPORT

Effect of Labial Frenum Notch Size and Palatal Vault Depth on Stress Concentration in Maxillary Complete Dentures: A Finite Element Study

Implant Overdentures: A New Standard of Care for Edentulous Patients Current Concepts and Techniques

Telescopic Denture A Treatment Modality for Minimizing the Conventional Removable Complete Denture Problems: A Case Report

The Mandibular Two-Implant Overdenture First-Choice. Standard of Care for the Edentulous Denture Patient

Abutment fracture in a bridge supported by natural teeth and implants

Decoding Heat Cure Denture Base Polymers. By Tom Zaleske

While the prosthetic rehabilitation of

Classification of dental cements

2016 Buy Up Dental Care Plan Procedure List

The inability to consistently achieve a passive fit with

everstick everstick fibre reinforcements in orthodontics Clinical Guide Reliable anchorage Aesthetic retention everstick ORTHO

ATLANTIS ISUS the benchmark for CAD/CAM suprastructures. For all major implant systems

RECURRENCE OF BENIGN OSTEOBLASTOMA OF THE MANDIBLE AND WITH A 4-YEAR-FOLLOW-UP: A CASE REPORT

Prosthetic treatment planning on the basis of scientific evidence.

THE VOICE OF TECHNO-CLINICAL DENTISTRY

Long-term success of osseointegrated implants

Complete Denture Processing Luther A. Ison, CDT

Clinical and Laboratory Procedures for Fixed Margin Implant Abutments

Khaldoon G. Abu Afifeh, B.D.S, M. Sc in Prosthodontics

Osseo-integrated Dental Implant Policy and Guidelines

Implant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration

The Hard and Soft Chairside Denture Reline

To provide care for the partially-dentate or edentulous

Implant Bar Overdenture Utilizing Locator Attachments

Renaissance of One-Piece Implants

Tamer A. Hamza, BDS, MSD, D.D.

Implant Parts. A Radford Heath Guide 1

Together with Course Program 2014

Supervisors: Dr. Farhan Raza Khan

In the Spring of 2010, the American Academy of Cosmetic

Fast Facts about Tooth Loss, Dentures & the Implant-Supported Dentures

In 1999, more than 1 million people in

ADA Standards Committee on Dental Products National Standards Status of Projects. Standard # Title of Standard WG Status Activity

PATIENT INFORM CONSENT for IMPLANT RESTORATION Rev

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

The history of complete denture impression procedures has been influenced largely by

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

THE PROFILE PROSTHESIS: AN AESTHETIC FIXED IMPLANT- SUPPORTED RESTORATION FOR THE RESORBED MAXILLA

All-on-4 treatment concept with NobelSpeedy Groovy

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

Modern Tooth Replacement Strategies & Digital Workflow

Milled Bar Overdentures-Protocol and Procedures

CUSTOMIZED PROVISIONAL ABUTMENT AND PROVISIONAL RESTORATION FOR AN IMMEDIATELY-PLACED IMPLANT

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

Ideal treatment of the impaired

More than a fixed rehabilitation.

Humana Health Plans of Florida. Important:

Dentalworkers JOB DESCRIPTIONS Great Team Members make your Office function!

Resorptive Changes of Maxillary and Mandibular Bone Structures in Removable Denture Wearers

General Dentist Fees

Teeth in a Day for the Maxilla and Mandible: Case Report

Dr. Little received his doctorate degree in dentistry from UT Health at San Antonio Dental

GIVE YOUR PATIENTS THE FREEDOM TO EAT, SPEAK AND LAUGH AGAIN.

Osseointegrated implant connected with natural tooth using a semiprecision attachment: A clinical report

20TDNH 214. Course Description:

York Region Ontario Works. Schedule of Denture Services and Fees. February 2011

Overdenture Implants versus Teeth Quality of Life and Objective Therapy Evaluation

Managing a Case of Sensitive Abutment Situations through Use of a Fixed Movable Prosthesis A Clinical Report

Case Report Mandibular Rehabilitation with Dental Implants: A case report

education Although demographic factors and growing patient awareness of the benefits of dental implants

Richmond Crown- A Conventional Approach for Restoration of Badly Broken Posterior Teeth

WIPE AND GO! No more time-consuming polishing of your provisionals. Structur 3. Structur 3

MALAYSIAN DENTAL JOURNAL. The Status Of The Abutment Teeth In Distal Extension Removable Partial Dentures

NARROW DIAMETER implant

CDT 2015 Code Change Summary New codes effective 1/1/2015

IMPRESSION TECHNIQUE AND MATERIALS

Ningbo Yinzhou Keao Prototyping & Mould Factory Services include : CNC machining prototypes,

The importance of uniform terminology and

(1) Maintenance of dental appearance and facial contour. (2) Minimizing disturbances of mastication and speech.

ALL-CERAMIC DENTAL IMPLANT SOLUTIONS

LOCATOR ROOT ATTACHMENT SYSTEM

Full Mouth Restoration with Screw-Retained Zirconia Bridges

Anterior crowns used in children

Full mouth rehabilitation of the patient with severely worn dentition: a case report

Jacket crown. Advantage : Crown and Bridge

Leslie Laing Gibbard, BSc, BEd, MSc, PhD, DDS George Zarb, BChD, DDS, MS, MS, FRCD(C)

Acceptability of maxillary major connectors in removable partial dentures

Transcription:

CLINICAL DENTISTRY AND RESEARCH 2014; 38(2): 31-35 Case Report AN ALTERNATIVE REINFORCMENT METHOD FOR MANDIBULAR IMPLANT RETAINED OVERDENTURES WITH E-GLASS FIBERS: A CASE REPORT Güliz Aktas, DDS, PhD Asistant Professor, Department of Prosthodontics, Duygu Karasan, DDS, PhD Department of Prosthodontics, Mehmet Muhtaroğulları, DDS, PhD Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Hacettepe, University, ABSTRACT Implant retained overdentures are the best treatment solutions for long time edentulism. However especially for un-reinforced mandibular overdentures with locator attachments, if the naturel dentition exists on the opposing arch, the most common failure is fracture of the acrylic denture base around the attachment clips. In this case report, acrylic base material of the fractured mandibular implant retained overdenture was reinforced with bidirectional e-glass fibers. Şenay Canay, DDS, PhD Profesor, Department of Prosthodontics, Correspondence Güliz Aktaş, DDS, PhD Department of Prosthodontics, Faculty of Dentistry, Hacettepe University Sıhhiye 06100, Phone: +90 312 3052240 Fax: +90 312 3113741 E-mail: g_emul@yahoo.com Key words: Feinforcement, Fiber, Overdenture Submitted for Publication: 09.05.2013 Accepted for Publication : 04.03.2014 31

CLINICAL DENTISTRY AND RESEARCH 2014; 38(2): 31-35 Olgu Bildirimi ALT ÇENE İMPLANT TUTUCULU OVERDENTURE PROTEZ İÇİN CAM- FİBER İLE ALTERNATİF GÜÇLENDİRME YÖNTEMİ: VAKA RAPORU Güliz Aktaş Yrd. Doç. Dr., Hacettepe Üniversitesi, Duygu Karasan Dr. Hacettepe Üniversitesi, ÖZET Uzun süreli tam dişsizliklerde implant destekli hareketli protezler en iyi tedavi yöntemidir. Ancak karşıt arkın doğal dentisyon olduğu durumlarda özellikle locator tutuculu güçlendirilmemiş alt hareketli protezlerde, tutucu klips çevresinde akrilik kaide materyalinin kırılması en sık görülen başarısızlıktır. Bu vaka raporunda,akrilik kaide materyali kırılan implant destekli alt protez çift yönlü cam fiber ile güçlendirilmiştir. Mehmet Muhtaroğulları Doç. Dr., Hacettepe Üniversitesi, Şenay Canay Prof. Dr., Hacettepe Üniversitesi, Sorumlu Yazar Güliz Aktaş, Hacettepe Üniversitesi, Sıhhiye 06100 Telefon: +90 312 3052240 Faks: +90 312 3113741 E-mail: g_emul@yahoo.com Anahtar Kelimeler: Güçlendirme, Fiber, Overdenture Yayın Başvuru Tarihi : 05.09.2013 Yayına Kabul Tarihi : 03.04.2014 32

Anxiety in mothers of infants with cleft lip and palate INTRODUCTION Conventional complete dentures pose some problems for edentulous patients with severely resorbed mandible or maxilla such as insufficient stability, retention, chewing ability and patient satisfaction. 1 Implant supported overdentures has become the viable standard treatment solution for the care of edentulous patients to overcome these problems. 2 However some technical complications such as acrylic resin denture base fracture 3 might occur when the insufficient space exists between the denture teeth and attachment system or the implant retained overdenture opposes naturel teeth or the implant supported prosthesis. 4 Many attempts have been made to enhance the strength of acrylic denture bases such as addition of the metal wire 5 or various types of fibers. 6,7 Cast metal wire is particularly helpful for reinforcement, but they might be unaesthetic, expensive and prone to corrosion. 8 Several mechanical laboratory studies demonstrated that adding glass fibers are useful for reinforcing the acrylic denture base materials. 9-12 Reinforced acrylic denture base material can be achieved either adding the glass fibers to whole denture base or only to the weak region. 13 In this case report acrylic base material of the fractured mandibular implant retained overdenture was reinforced with bidirectional glass fibers. CASE REPORT A 72 year-old man presented to the department of prosthodontics, with a fractured mandibular implant retained overdenture (Figure 1). Intraoral examination showed that his opposing dentition was natural dentition and his mandibular implant retained overdenture was not reinforced with any material. The initial treatment plan was to repair of the fractured mandibular overdenture by rejoining pieces of a fractured denture base using an auto polymerizing resin. After this repair, 2 mm thickness of the denture base material was removed from the tissue side of the prosthesis to relining procedure and denture surface was roughened. Zinc oxide eugenol impression material (SS White Manufacturing, Gloucester, England) was placed directly on the tissue surface of denture base; afterwards the denture was inserted into the patient s mouth. Thus, the old base was used as an impression tray. The denture with eugenol impression material was invested in the drag of the denture processing flasks using type II dental plaster(snow white plaster; Kerr, Romulus, Mich).The undercuts in the investment Figure 1. Fractured mandibular implant retained overdenture were removed and the investment was allowed to set. Housing part of the attachment with black processing patrix was filled using condensation silicone material (Speedex, Coltane, Switzerland). A thin layer of separating medium (modern material separating Medium; HerausKulzer) was applied to the surfaces of the investment. The cope was positioned in place and a second mix of type II plaster was poured into the flask until the ring was filled completely and the top of the flask placed in position. The flask was placed in a boil tank for 10 min. to eliminate the impression material. The remaining impression material was rinsed with hot running water after separating the cope and drag. A layer of the separating medium was applied to the plaster of the investment in both portions. Bidirectional glass fibers were impregnated with powder-liquid mixture in an aluminum foil for about 10 min. until they became transparent (Figure 2A, 2B). Heat-polymerized polymathacrylate resin (Meliodent; HerausKulzer GmbH & Co. KG, Hanau, Germany) was mixed according to manufacturer s instructions and packed in doughy stage at 200 Psi for 3 trial packs using 10x10 clear separating sheets. At the third trial the transparent bidirectional glass fibers were placed on the tension side of the mandibular overdenture (Figure 3). The flask was clamped and polymerized at 100 0 Cfor 1 hour from the time of initial placement into the boiling water. Following the cooling process, the two parts of the flask was separated (Figure 4); afterwards the overdenture was finished and polished. The black processing attachments were replaced with blue matrixes. The patient was followed up for 1-year period with recalls in every 4 month. 33

CLINICAL DENTISTRY AND RESEARCH Figure 2A. Polymathacrylate resinpowder-liquid mixture Figure 4. Reinforced overdenture before finishing and polishing procedures DISCUSSION Figure 2B. Impregnation of the e-glass fibersin an aluminum foil The presence of bidirectional e-glass fibers would significantly increase the fracture strength of the implant retained overdenture during the one year follow up. Not only in-vitro studies14, 15 but also clinical studies16, 17 revealed that adding glass fibers are efficient in reinforcing acrylic denture base resin. In this case report the glassfiber reinforcement was placed to the tension side of the overdenture, between and around the locator housings. The placement of the e-glass fibers in the most expected tension area was consistent with other studies.18, 19 The increased modulus of elasticity from the embedded fibers themselves may play an important role on the mechanism of improved fracture resistance.20 The amount of fiber layers and the use of polymethile-methacrylate impregnation may also have impacted the reinforcement. However, type of fibers or distribution of them remains as a question to provide the highest increase on the fracture strength. These aspects should be investigated in future laboratory studies. CONCLUSION Fractured mandibular implant retained overdentures may be reinforced by adding bidirectional glass fibers to the weak regions of the acrylic resin base. REFERENCES Figure 3. Insertion of the e-glass fibers to the denture base 1. van Waas MA. The influence of clinical variables on patients satisfaction with complete dentures. J Prosthet Dent 1990; 63: 307-310. 2. Fein JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S 34

Anxiety in mothers of infants with cleft lip and palate et al. The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standart of care for edentulous patients. Gerodontology 2002; 19: 3-4. 3. Hemmings KW, Schmitt A, Zarb GA. Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: a 5-year report. Int J Oral Maxillofac Implants 1994; 9: 191-196. 4. Zitzmann NU, Marinello CP. A review of clinical and technical considerations for fixed and removable implant prostheses in the edentulous mandible. Int J Prosthodont 2002; 15: 65-72. 5. Ruffino AR. Effect of steel strengtheners on fracture resistance of the acrylic resin complete denture base. J Prosthet Dent 1985; 54: 75-78. 6. Bowman AJ, Manley TR. The elimination of breakages in upper dentures by reinforcement with carbon fibre. Br Dent J 1984; 156: 87-89. reinforcement. Int J Prosthodont 2001; 14: 219-224. 17. Goguta LM, Bratu D, Jivanescu A, Erimescu R, Marcauteanu C. Glass fibre reinforced acrylic resin complete dentures: a 5-year clinical study. Gerodontology 2012; 29: 64-69. 18. Dyer SR, Lassila LV, Jokinen M, Vallittu PK. Effect of crosssectional design on the modulus of elasticity and toughness of fiber-reinforced composite materials. J Prosthet Dent 2005; 94: 219-226. 19. Kanie T, Fujii K, Arikawa H, Inoue K. Flexural properties and impact strength of denture base polymer reinforced with woven glass fibers. Dent Mater 2000; 16: 150-158. 20. John J, Gangadhar SA, Shah I. Flexural strength of heatpolymerized polymethyl methacrylate denture resin reinforced with glass, aramid, or nylon fibers. J Prosthet Dent 2001; 86: 424-427. 7. Chen SY, Liang WM, Yen PS. Reinforcement of acrylic denture base resin by incorporation of various fibers. J Biomed Mater Res 2001; 58: 203-208. 8. Carroll CE, von Fraunhofer JA. Wire reinforcement of acrylic resin prostheses. J Prosthet Dent 1984; 52: 639-641. 9. John J GS, Shah I. Flexural strength of heat- polymerized polymethyl methacrylate denture resin reinforced with glass, aramid, or nylon fibers. J Prosthet Dent 2001; 86: 424-427. 10. Nagai E, Otani K, Satho Y, Suzuki S. Repair of denture base resin using woven metal and glass fiber: effect of methylene chloride pre-treatment. J Prosthet Dent 2001; 85: 496-500. 11. PK V. A review of fiber-reinforced denture base resins. J Prosthod 1996; 5: 270-276. 12. Vallittu PK, Ruyter IE, Ekstrand K. Effect of water storage on the flexural properties of E-glass and silica fiber acrylic resin composite. Int J Prosthodont 1998; 11: 340-350. 13. Vallittu PK. Glass fiber reinforcement in repaired acrylic resin removable dentures: preliminary results of a clinical study. Quintessence Int 1997; 28: 39-44. 14. Vallittu PK. Flexural properties of acrylic resin polymers reinforced with unidirectional and woven glass fibers. J Prosthet Dent 1999; 81 : 318-326. 15. Narva KK, Lassila LV, Vallittu PK. The static strength and modulus of fiber reinforced denture base polymer. Dent Mater 2005; 21: 421-428. 16. Narva KK, Vallittu PK, Helenius H, Yli-Urpo A. Clinical survey of acrylic resin removable denture repairs with glass-fiber 35