Enterprise-optimised 6-Gb/s SAS rivals Fibre Channel Performance and Scalability at Lower Cost



Similar documents
Transitioning to 6Gb/s SAS (Serial-Attached SCSI) A Dell White Paper

Seagate Instant Secure Erase Deployment Options

Self-Encrypting Hard Disk Drives in the Data Center

Maximizing Server Storage Performance with PCI Express and Serial Attached SCSI. Article for InfoStor November 2003 Paul Griffith Adaptec, Inc.

iscsi: Accelerating the Transition to Network Storage

Storage Synergies: Adaptec Series 5 Unified Serial Controllers and Seagate Barracuda ES.2 SAS Drives

Virtualization. Disaster Recovery. A Foundation for Disaster Recovery in the Cloud

WHITE PAPER Addressing Enterprise Computing Storage Performance Gaps with Enterprise Flash Drives

Open-E Data Storage Software and Intel Modular Server a certified virtualization solution

Enterprise SSD Interface Comparisons

Increase Database Performance by Implementing Cirrus Data Solutions DCS SAN Caching Appliance With the Seagate Nytro Flash Accelerator Card

PrimeArray Data Storage Solutions Network Attached Storage (NAS) iscsi Storage Area Networks (SAN) Optical Storage Systems (CD/DVD)

Hitachi Storage Solution for Cloud Computing

Using HP StoreOnce Backup Systems for NDMP backups with Symantec NetBackup

White Paper: M.2 SSDs: Aligned for Speed. Comparing SSD form factors, interfaces, and software support

White Paper. Enhancing Storage Performance and Investment Protection Through RAID Controller Spanning

Block based, file-based, combination. Component based, solution based

SCSI vs. Fibre Channel White Paper

Enterprise Disk Storage Subsystem Directions

Chapter 13 Selected Storage Systems and Interface

White paper 200 Camera Surveillance Video Vault Solution Powered by Fujitsu

Lowering Cloud & Data Center TCO with SAS Based Storage. Seagate Mark E. Wojtasiak. Xyratex Michael K. Connolly Michael A. Hoard Linda Tillis, P.E.

SAS & FC COMPARED THE R/EVOLUTION DIFFERENCE. white paper. SAS vs. FC

Top Ten Reasons for Deploying Oracle Virtual Networking in Your Data Center

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

Serial ATA in Servers and Networked Storage

How to Test VDI Scalability and Performance on a Windows Server 2012 R2

Achieving Higher VDI Scalability and Performance on Microsoft Hyper-V with Seagate 1200 SAS SSD Drives & Proximal Data AutoCache Software

Flash Memory Technology in Enterprise Storage

Integration of Microsoft Hyper-V and Coraid Ethernet SAN Storage. White Paper

SummitStack in the Data Center

Best Practices RAID Implementations for Snap Servers and JBOD Expansion

White Paper: Understanding Network and Storage Fabric Challenges in Today s Virtualized Datacenter Environments

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

Dell PowerVault MD Family. Modular storage. The Dell PowerVault MD storage family

Optimizing Large Arrays with StoneFly Storage Concentrators

Accelerate SQL Server 2014 AlwaysOn Availability Groups with Seagate. Nytro Flash Accelerator Cards

The Transition to PCI Express* for Client SSDs

NetApp E-Series Storage Systems

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

128-Bit Versus 256-Bit AES Encryption

Achieving Flexible Storage Scalability

THE VX 9000: THE WORLD S FIRST SCALABLE, VIRTUALIZED WLAN CONTROLLER BRINGS A NEW LEVEL OF SCALABILITY, COST-EFFICIENCY AND RELIABILITY TO THE WLAN

Direct Scale-out Flash Storage: Data Path Evolution for the Flash Storage Era

Scala Storage Scale-Out Clustered Storage White Paper

CASE STUDY SAGA - FcoE

DAS, NAS or SAN: Choosing the Right Storage Technology for Your Organization

White Paper. Fueling Successful SMB Virtualization with Smart Storage Decisions. 89 Fifth Avenue, 7th Floor. New York, NY

Storage Solutions to Maximize Success in VDI Environments

SCI Briefing: A Review of the New Hitachi Unified Storage and Hitachi NAS Platform 4000 Series. Silverton Consulting, Inc.

Technology Note. PCI Express

SummitStack in the Data Center

Fibre Forward - Why Storage Infrastructures Should Be Built With Fibre Channel

Dell Desktop Virtualization Solutions Simplified. All-in-one VDI appliance creates a new level of simplicity for desktop virtualization

Post Production Video Editing Solution Guide with Apple Xsan File System AssuredSAN 4000

IBM PureFlex System. The infrastructure system with integrated expertise

Cisco Unified Data Center: The Foundation for Private Cloud Infrastructure

W H I T E P A P E R B r i n g i n g C l a r i t y t o H a r d Disk Drive Choices for Enterprise Storage Systems

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

Enterprise SATA and Near-Line Storage ULTAMUS TM RAID

Data Sheet Fujitsu ETERNUS CS High End V5.1 Data Protection Appliance

DELL RAID PRIMER DELL PERC RAID CONTROLLERS. Joe H. Trickey III. Dell Storage RAID Product Marketing. John Seward. Dell Storage RAID Engineering

Sustaining the Cloud with a Faster, Greener and Uptime-Optimized Data Center

IBM System Storage DS5020 Express

SYSPRO Integration SYSPRO Integration Framework

Edges. Extending Data Center SAN Advantages to the Workgroups. Kompetenz in SCSI, GmbH. Fibre & Fiber

Business-centric Storage for small and medium-sized enterprises. How ETERNUS DX powered by Intel Xeon processors improves data management

HP iscsi storage for small and midsize businesses

Storage is in Our DNA. Industry-leading 12Gb/s and 6Gb/s Storage Solutions RAID Adapters, Host Bus Adapters, and SAS Expander

PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector

Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4

VAS ConSolidAtion, VirtuAliSAtion And the Cloud Pieter oonk, ProduCt MAnAger

Backup Exec 9.1 for Windows Servers. SAN Shared Storage Option

Business-centric Storage for small and medium-sized enterprises. How ETERNUS DX powered by Intel Xeon processors improves data management

QLogic 16Gb Gen 5 Fibre Channel in IBM System x Deployments

Enterprise Storage Solutions and Services

Affordable. Simple, Reliable and. Vess Family Overview. VessRAID FC RAID Storage Systems. VessRAID SAS RAID Storage Systems

Server Virtualization: Avoiding the I/O Trap

Windows TCP Chimney: Network Protocol Offload for Optimal Application Scalability and Manageability

Torpedo Design Concept Storage Server for Open Rack Hardware v0.3 ST-draco-chimera-0.3

6Gb/s MegaRAID SAS RAID Controllers

nexsan NAS just got faster, easier and more affordable.

iscsi Boot Functionality: Diskless Booting Enables SANlike Benefits at Lower Costs

CUTTING-EDGE SOLUTIONS FOR TODAY AND TOMORROW. Dell PowerEdge M-Series Blade Servers

Symantec NetBackup 5220

Redundancy in enterprise storage networks using dual-domain SAS configurations

The Evolution of Solid State Storage in Enterprise Servers

Breaking through the haze: understanding

Dell Desktop Virtualization Solutions (DVS) Enterprise

Get More Scalability and Flexibility for Big Data

Hitachi Cloud Services for Private File Tiering. Low Risk Cloud at Your Own Pace. The Hitachi Vision on Cloud

HP iscsi storage solution guide

SCSI Standards and Technology Update: SAS and SCSI Express

IBM Global Business Services Microsoft Dynamics CRM solutions from IBM

Cloud CRM. Scalable solutions for enterprise deployment

Consolidate and Virtualize Your Windows Environment with NetApp and VMware

Transcription:

Technology Paper Enterprise-optimised 6-Gb/s SAS rivals Fibre Channel Performance and Scalability at Lower Cost Introduction In just a few short years Serial Attached SCSI (SAS) has fundamentally altered the enterprise storage landscape. Building on the rock-solid reliability and robust command set of its parallel SCSI predecessor, SAS has raised the storage bar with an unprecedented combination of performance (3-Gb/s transfer rate), scalability (thousands of devices in one domain) and flexibility (compatibility with SATA). In Q3 2005, 3-Gb/s SAS systems entered the market, and by 2007 they were shipping in large quantities. SAS has supplanted parallel SCSI as the direct-attached SCSI interface of choice throughout the enterprise; indeed, it was one of the fastest interface transitions in market history. This rapid transition relied on the close working relationship between the SCSI Trade Association (STA) and the T10 Committee. The STA focuses on identifying SCSI s marketing requirements and providing the forum to reach a consensus on features and benefits included in the SCSI roadmap, while the role of the T10 Committee is to develop standard specifications to make it possible for those features and benefits to be implemented in commercial products. The T10 Committee developed the new SAS-2 technical specification (SAS protocol and physical interface enhancements for transporting SCSI over serial links at up to 6 Gb/s), and the STA has given the marketing name 6-Gb/s SAS to this new industry standard (see Figure 1).

12-Gb/s SAS Leading Edge = First Plug-fest 6-Gb/s SAS 3-Gb/s SAS End-User Products: ~12-18 months later Ultra 320 SCSI 2003 2004 2005 2006 2007 2008 2009 2110 2011 2012 2013 2014 2015 Graphic copyrighted by SCSI Trade Association. Figure 1. SAS Roadmap With the recent introduction of this new SAS-2 standard specification, SAS is once again poised to rewrite the rules for enterprise storage, this time setting its sights on the data centre s premier interface, Fibre Channel (FC). According to the STA, 6-Gb/s SAS has many enhancements beyond 3-Gb/s SAS. It has more bandwidth per connection, greater scalability and enhanced features. 3-Gb/s SAS usage models will be preserved in 6-Gb/s SAS, along with the retention of 1.5-Gb/s and 3-Gb/s SAS/SATA compatibility. There are many other targeted improvements beyond first-generation 3-Gb/s SAS, assuring enterprise storage users that SAS technology will continue to meet their needs. While its blazing 6-Gb/s transfer rate (double that of the previous generation) is the most obvious attribute of the SAS-2 specification, a comprehensive suite of additional enhancements enables 6-Gb/s SAS to rival FC solutions in a variety of enterprise storage environments - at significantly lower cost. Moreover, 6-Gb/s SAS does so whilst retaining compatibility with earlier SAS and SATA hard drives. Key 6-Gb/s SAS features include standardised expander zoning and expander self-discovery, which enable more secure and efficient scalability when deploying the enormous number of drives increasingly found in high-end enterprise arrays. Factor in the faster throughput, longer maximum cable lengths and greater signal integrity, and it becomes clear that 6-Gb/s SAS is a compelling, cost-effective rival to FC in many network storage applications. More Storage, Less Expense Satisfying the enterprise s relentless hunger for greater storage capacity and faster throughput poses a difficult challenge for today s storage professionals, who are also expected to cut costs whenever possible. FC has long been the preferred interface for a variety of network storage architectures used in enterprise data centres: SAN (storage area network) NAS (network attached storage) JBOD/RAID (just-a-bunch-of-discs/redundant array of independent discs) Of course, FC is also known for coupling its remarkable throughput and scalability with daunting costs. Beyond the substantial investment required for the infrastructure itself, Fibre Channel solutions also entail complex deployment and 2

6-Gb/s SAS: Performance, flexibility and value in affordable and easy-to-manage storage environments Feature/Function 6-Gb/s transfer rate Standardised expander zoning Expander self-discovery 10-M cable length Greater signal integrity with SSC Cost-effective simplification Investment protection Management efficiencies Benefit Enables enterprise-class performance at 2x the throughput of today s SAS/SATA environments Provides common infrastructure with seamless scalability Provides common infrastructure with seamless scalability Extends connectivity by 66 per cent, supporting networked storage expansion beyond a single rack Enables 6-Gb/s SAS drives to be installed in close proximity to one another without compromising data integrity Simplified connectivity with standardisation on mini-sas connectors Retains compatibility with earlier SAS/SATA hard drives and SCSI software/ middleware Uses existing IT SCSI expertise Figure 2. Features and Benefits of 6-Gb/s SAS management procedures that require highly specialised (and expensive) expertise not found in many IT departments. Hence, FC has generally been limited to enterprises with the needs (and deep pockets) to justify its use. Devices with 6-Gb/s transfer rates deliver greater performance, flexibility and value in traditional direct-attached applications such as internal server storage. But more importantly, 6-Gb/s SAS storage solutions now offer an affordable, easyto-manage alternative to FC in network storage environments. Achieving this capability required several key enhancements to the SAS standard developed by the T10 Committee 1. These new key enhancements are detailed in the following sections: Standardised Expander Zoning Standardised expander zoning provides common infrastructure with seamless scalability. While the SAS-1 specification theoretically enabled enormous addressability (up to 128 expanders, each supporting up to 128 SAS devices), in practice even a few hundred storage devices or subsystems required some type of zoning scheme to assign storage domains when used with multiple hosts. This capability, known as expander zoning, was not formally defined in the SAS-1 standard. Therefore, this zoning could be implemented in a variety of vendor-specific, and frequently inconsistent, ways that result in zoning incompatibilities leading to inaccessible storage and/or limit customers to single-vendor solutions. To eliminate such incompatibilities, standardised expander zoning is part of the SAS-2 specification and a required feature in all 6-Gb/s SAS expanders. Furthermore, expanders can now support up to 256 devices. Also, 6-Gb/s SAS expanders support secure zones, similar to fibre channel SAN zones. Using denial of service and device access control by zone technologies, networked storage can be grouped so that multiple hosts may talk to the expander, but only see a specified subset of the storage devices. This provides greater data security and makes storage easier to manage in the multi-drive network storage environments typical of enterprise data centres. 3 1 The T10 Committee (www.t10.org) is part of the International Committee on Information Technology Standards (INCITS) and is accredited by, and operates under, rules approved by the American National Standards Institute (ANSI). These rules are designed to ensure that voluntary standards are developed by the consensus of industry groups such as the SCSI Trade Association (SCSITA, www.scsita.org).

Expander Self-Discovery Expander self-discovery simplifies administration, while doubling storage scalability. Under the SAS-1 standard, connecting devices to the expanders was a host-based process. As long as the number of SAS drives in the storage pool was relatively small, this discovery scheme was reasonably efficient. But in network storage environments, where massive numbers of drives are typically employed, host-based discovery resulted in increased SAS messaging traffic between hosts and expanders, and more time was needed to initialise systems. The SAS-2 standard resolves this issue by shifting the SAS discovery process from the host to the expander. Enabling 6-Gb/s SAS expanders to perform device discovery themselves, automatically and in parallel, makes the provisioning of large systems of SAS drives both faster and easier to manage. This expander self-discovery technology plays a pivotal role in ensuring seamless scalability as network storage needs (and storage device quantities) inevitably grow. 6-Gb/s SAS: Optimised for the Enterprise While the impressive capabilities of 6-Gb/s SAS in network storage environments clearly stem from the inclusion of standardised expander zoning and expander self-discovery technologies, they are not the only aspects of the SAS-2 standard that make 6-Gb/s SAS so effective in enterprise storage arrays. Indeed, 6-Gb/s SAS incorporates a variety of enterprise-centric features, including: 6-Gb/s Transfer Rate The 6-Gb/s transfer rate enables rock-solid enterprise-class performance at twice the throughput of today s SAS or SATA environments. Higher throughput is always a desirable feature in any storage solution, but it is particularly important in enterprise data centres, where drives can be accessed repeatedly by multiple initiators. With double the transfer rate of its 3-Gb/s SAS predecessor, 6-Gb/s SAS delivers the speed necessary to keep up with the demands of hightraffic network storage environments. Delivering performance that is competitive and significantly less expensive than FC storage solutions, 6-Gb/s SAS also offers a more compelling performance/price value proposition than costly solid state drives (SSDs). 10-Metre Maximum Cable Length A 10-metre maximum cable length extends connectivity by 66 per cent, supporting networked storage expansion beyond a single rack. 6-Gb/s SAS delivers a remarkable 100 per cent boost in transfer rate, while also enabling the use of longer connecting cables (up to 10 metres: an increase from the 6-metre cables supported by 3-Gb/s SAS). Achieving this improvement in throughput and maximum cable length required the use of decision feedback equalisation (DFE) technology. DFE counteracts the signal attenuation effects that arise from greater cable lengths by deemphasising lower frequency components at the transmitter and selectively boosting higher frequency components on the receiving end. This enables the use of 10-metre cables with no loss of signal integrity, while still maintaining compatibility with existing six-metre cables. This 66 per cent increase in maximum cable length pays significant dividends in the data centre, enabling far greater flexibility in terms of widescale storage system deployment and installation. This cable extension provides the flexibility to expand your network-attached storage beyond the limits of a single rack, using a 10-metre cable while ensuring the integrity of the data. Spread Spectrum Clocking 6-Gb/s SAS doubles the data frequency of 3-Gb/s SAS; this may result in a loss of cabinet shielding efficiency due to the shorter wavelengths of the signals. To combat this change in frequency, 6-Gb/s SAS employs spread spectrum clocking (SSC), a slow-frequency (30 33 Khz) modulation of the data frequency. By reducing the peak values and spreading the radiated emissions over a broader range of frequencies, SSC helps to reduce EMIrelated issues. Simplified Connectivity Simplified connectivity standardises on mini-sas connectors for cost-effective SAS solutions. To simplify cabling options and to streamline integration, 6-Gb/s SAS eliminates the expensive InfiniBand-style (SFF-8470, Figure 3) connector 4

Graphics copyrighted by SCSI Trade Association, courtesy of Molex. Figure 3. Costly InfiniBand-style connector used by 3-Gb/s SAS used by 3-Gb/s SAS and relies solely on the mini- SAS connector for both internal (SFF-8087) and external (SFF-8088, Figure 4) connectivity. Standardising on mini-sas connectors is particularly appropriate for the data centre, where these connectors are becoming increasingly commonplace through their use on small form factor (SFF) 2.5-inch hard drives. Investment Protection with Backwards Compatibility Given the numerous technical advancements that the new SAS-2 specification incorporates, it may be surprising to learn that 6-Gb/s SAS maintains full 1.5-Gb/s and 3-Gb/s SAS/SATA compatibility. To further ensure seamless interoperability, existing SCSI software and middleware compatibility is also retained. Such compatibility is key to ensuring that the enterprise s current installed base of SAS storage solutions will continue to maintain its value as the transition to 6-Gb/s SAS gains momentum. Graphics copyrighted by SCSI Trade Association, courtesy of Molex. Figure 4. Compact, cost-effective, mini-sas connectors used by 6-Gb/s SAS Conclusion With growing pressure throughout data centres to cut spending while keeping pace with the inexorable demand for more storage capacity and speed, the steep cost and complexity of fibre channel solutions have become increasingly problematic. The arrival of 6-Gb/s SAS provides a compelling, cost-effective alternative, boasting performance and scalability that rivals fibre channel. 6-Gb/s SAS delivers a more economical and far simpler alternative to purchase, install and maintain for business sustainability. AMERICAS Seagate Technology LLC 920 Disc Drive, Scotts Valley, California 95066, United States, +1 831 438 6550 ASIA/PACIFIC Seagate Singapore International Headquarters Pte. Ltd. 7000 Ang Mo Kio Avenue 5, Singapore 569877, +65 6485 38880 EUROPE, MIDDLE EAST AND AFRICA Seagate Technology SAS 130-136, rue de Silly, 92773 Boulogne-Billancourt Cedex, France, +33 1 41 86 10 00 Copyright 2009 Seagate Technology LLC. All rights reserved. Printed in USA. Seagate, Seagate Technology and the Wave logo are registered trademarks of Seagate Technology LLC in the United States and/or other countries. Seagate reserves the right to change, without notice, product offerings or specifications. TP603.1-0905GB, May 2009