Operating Manual Style FX 100/400



Similar documents
Operating Manual Style RX 300 Style RX 600 Style RX 1200 Version 230V Version 230V Version 230V

Operating Manual Ranger RX Battery Power Pack

Transmitter Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso

EL-Skyport Universal Receiver Speed Triggers flashes or cameras and receives - transmits basic information to the computer remote control.

FlexFlash Instruction Manual Models SB FLXFLSH400W, SB FLXFLSH200W, SB FLXFLSHE400W, SB FLXFLSHE200W

2013 VTech Printed in China US

IMAGE BY: STEFAN DITNER Ws THE REINVENTION OF A CLASSIC...

Operating Instructions Bedienungsanleitung Mode d emploi

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

4.3-inch Back-Up Camera

aseries A13B Mini Bullet Camera User Manual

Introduction. Setting Up Your Remote Installing the Battery. Contents. System Requirements

Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

User Guide Nokia Portable Wireless Charging Plate DC-50

User manual. Your best protection against theft and loss. (Android) Made for

Dear Customer! Thank you for choosing our product.

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

Wireless Phone Jack System

ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

Model 70A00-1. GSM Cellular Communications Center

StructureScan HD Module. Installation Guide ENGLISH

Weather Radio Alarm Clock

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

SanDisk Connect Wireless Flash Drive QUICK START GUIDE

Bluetooth Stereo Headphone. User Guide. Hive

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

Mini Power Bank and Charger

How To Use The M500 Light Bulb With A Flash Power Of 500 Ws

Congratulations! Thank you!

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

Caller-ID on your TV!

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

EF-S18-55mm f/ IS II COPY ENG. Instruction

Personal Assistance System Owner's Guide

Introduction. Setting Up Your Remote Installing the Battery. Contents. System Requirements

How To Use A U.S. Cell Phone At Home

SPL 2-00/-01 OPERATION INSTRUCTIONS

BTX180 Wireless Bluetooth Speaker

Atomic Projection Alarm with Indoor and Outdoor Temperature

Wireless Alarm System. Alarm Siren. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Panasonic. Proprietary Telephone for Electronic Modular Switching System MODEL NO. KX Illustrated Model: White 1

The Third Rail System User Manual

THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions

Product Overview. Product Interface

User Guide Microsoft Screen Sharing for Lumia Phones (HD-10)

SATA and SAS Hard Drive Backplane

ORLAND FOLLOW PR-1211

READ FIRST! Universal Car/Air Adapter User Manual

Contents. Product Code Page 1

W O R L D C L A S S H I F I

ENERGY AWARE. Monitor User Guide

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

2XWSXWFKDQQHOV 3KDVH &+ CH 2 &+ CH 4 &+ CH 6 L1 X X L2 X X L3 X X

User Guide. Soft-Touch TM Bluetooth Laser Mouse N2953

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power

NFC Communication Tray Model: HHX-IT3-Z

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Manual. Simrad StructureScan LSS-1 Sonar Module. English

IFS SP-PoE Splitter User Manual

Operating Manual. LCD Monitor

Wireless Mouse USER GUIDE. for Mac. ONE YEAR LIMITED WARRANTY N2953

Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide

EF-S18-135mm f/ IS

INFINEA TAB USER MANUAL. INFINEA ipad TAB

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

User Manual 使 用 者 指 南. Aputure Manufacturing Authority

How To Operate A Broncolor Power Pack

Wireless Indoor/ Outdoor Thermometer

Energy Smart Electric Water Heater Controller

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Broadband Telecommunications Drop Amplifier

Stretch DisplayPort TM

Kinivo 301BN HDMI Switch

User Manual CABLE TESTER CT100. Professional 6-in-1 Cable Tester

BOSE. Link AL8 HOMEWIDE WIRELESS AUDIO LINK

Wireless Security System. Wireless Security Camera. SI519 Instructions. SI513 Instructions. Read and save these instructions.

Dome Security Camera with IR night vision

FB-500A User s Manual

BeoLab 7-1 BeoLab 7-2. Guide

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

Installer Guide smart connect

PROGRAMMER INSTALLATION INSTRUCTIONS

ATTENTION RISQUE D ÉLECTROCUTION! NE PAS OUVRIR!

Model: Manual DC: WIRELESS COLOR FORECAST STATION

WPR400 Wireless Portable Reader

Wireless Alarm System. Silent Alert. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

InnoMedia ESBC B. Quick Install Guide. 1

Owner s Instruction Manual. 2500/2554 Telephones Message Waiting

Power supply unit Model: PAC-SC50KUA

Infrarot-Bewegungsmelder IP44

IMPORTANT SAFETY INSTRUCTIONS

esata External Storage

7 High-Resolution Digital Photo Frame

USER GUIDE. Access to the Server is via the following webpage:

Transcription:

elinca sa switzerland www.elinchrom.com Operating Manual Style FX 100/400 Elinca S.A Style FX 01.01.2007 DE (73276) Printed in Switzerland Deutsch 190/260V

Table of contents Introduction 2 Declaration of conformity, disposal and recycling, CE marking 3 Safety notice and precaution 4 Operating instructions 5 Control Panel 6 Switch and Fuse 7 Modelling Light 8 Digital power display, Photo-cell 9 Synchronisation, Wireless Remote control and flash triggering 10 Acoustic signal 10 DVD, «The beginner s guide to light» 11 Troubleshooting 7, 11 Technical Data 12 Elinchrom Accessories 13 Guarantee 14 PS Technical data subject to change. The listed values are guide values which may vary due to tolerances in components used. 1

Introduction The Elinchrom Style FX is manufactured by Elinca S.A. CH -1020 Renens/Switzerland Dear Photographer, Thank you for buying your Style FX compact flash unit. All Elinchrom products are manufactured using the most advanced technology. Carefully selected components are used to ensure the highest quality and the equipment is submitted to many controls both during and after manufacture. We trust that it will give you many years of reliable service. All Style FX flash units are manufactured for the studio and location use of professional photographers. Only by observance of the information given, can you secure your warranty, prevent possible damage and increase the life of this equipment. Style 100FX - 400FX The quality of light and exceptional performance is the result of long research, application of demanding principles, the long experience of ELINCHROM in lighting products for the studio and the utilization of the latest technology in this area. Totally integrated to the range of the ELINCHROM flashes, the Style 100FX - 400FX units maintain the traditional look and function that is ELINCHROM. The control provides continuously variable adjustment of the modelling lamp and the flash power with precision over 5 f-stop, from full power 1/1 to 1/16 th. FCC Class B Compliance Statement Note This equipement has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC Rules and meets all requirements of the Canadian Interference-Causing Equipement Regulations. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipement generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipement does not cause harmful interferences to radio or television reception, which can be determined by turning the equipement off and on, the user is encouraged to correct the interferences by one or more of the following measures - Reorient or relocate the receiving antenna. - Increase the separation between the equipement and receiver. - Connect the equipement into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/tv technician for help. ELINCA S.A. is not responsible for any radio or television interference caused by unauthorised modifications of this equipement or the substitution or attachment of connecting cables and equipement other than those specified by ELINCA S.A. The correction of interference caused by such unauthorised modification, substitution or attachment will be the responsibility of the user. 2

Declaration of conformity This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Product name Professional Studio Flash unit Trade name ELINCHROM Model number(s) Style FX 100/400 Name of responsible party Elinca S.A Av. De Longemalle 11 1020 Renens / Switzerland Phone +41 21 637 2677 Fax +41 21 637 2681 We, ELINCA S.A., hereby declare that the equipement bearing the trade name and model number specified above was tested conforming to the applicable FCC rules, and that all the necessary steps have been taken and are in force to assure that the production units of the same equipement will continue to comply with the Comissions requirements. Disposal and recycling This device has been manufactured to the highest possible degree from materials which can be recycled or disposed of in a manner that is not enviromentally damaging. The device may be taken back after use to be recycled, provided that is returned in a condition that is the result of normal use. Any components not reclaimed will be disposed of in a environmentally acceptable manner. If you have any question on disposal, please contact your local office or your local ELINCHROM agent (check our website for a list of all ELINCHROM agents world wide). CE marking The shipped version of this device complies with the requirements of ECC directives 89/336/ECC «Electromagnetic compatibility» and 73/23/ECC «Low voltage directive». Notational Conventions The meaning of the symbols and fonts used in this manual are as follows! Pay particular attention to text marked with this symbol. Failure to observe this warning endangers your life, destroys the device, or may damage other equipement i Supplementary information, remarks, and tips follow this symbol. Text which follows this symbol describes activities that must be performed in the order shown. «Quotation marks» indicate names of chapters or terms 3

Safety notice According to safety regulations, we draw your attention to the fact that these electronic flash units are not designed for use outdoors, in damp or dusty conditions and should not be used after being exposed to sudden temperature changes causing condensation. They must always be connected to an earthed (grounded) mains supply. On no account should any object be inserted into the ventilation holes. The units may retain an internal charge for a considerable time even though disconnected from the power supply. Do not use in restricted areas (like hospitals, etc.). Do not use in explosive environnements. Flash Tubes and Modelling lamps Flash tubes and modelling lamps in use are very hot! Never touch a flash tube or lamp before the unit cooled down and is disconnected from the mains (min 30mn). Do not fire flashes from short distance (less than 1m) directed to a person and avoid looking directly into the flashlight! Keep (min 1m) distance to flammable materials. Keep generally distance to operating units. Transport Transport the flash unit with care and only in its original packaging or another corresponding packaging fit to protect it against knocks and jolts. Transport only in complete discharged conditions. Wait a minimum 30 minutes after removing from mains supply before packaging and transportation. Never drop the flash unit (danger of glass breakage) Power cable To guarantee safe operation, use the cable supplied. The cable has to be HAR-certified or VDE-certified. the mark HAR or VDE will appear on the outer sheat. The cable set must be selected according to the rated current for your flash unit. Do not use a spider box to connect one or more flash units.! Flash systems store electrical energy in capacitors by applying high voltage. For your safety, never open or disassemble your flashes. Only an authorised service engineer should open or attempt to repair the units. Internal defect charge capacitors may explode whilst the unit is in use, neve switch on a proper working flash unit. 4

Before you start! The Style FX are adapted for operation on 190-260V/50-60Hz. Before connecting for the first time, check to make sure that your modelling lamp coincides with the voltage line. They must always be connected to an earthed ( grounded) mains supply. All Style FX units have a bayonet mount and locking ring reflector fitting, for fixing all Elinchrom and Prolinca accessories. Mount the unit securely to a suitable stand or support. Remove the black protective cover (note first turn the locking ring A as shown, then rotate the black cap cover B in the same direction). Fitting a reflector or accessory is the reverse of this action. DO NOT operate the unit without first removing the black protective cover. Operating instructions 1.Check that the modelling lamp voltage is correct. 2.Check that the mains switch (3) is in the OFF ("O" position). 3.Insert mains cable to the MAINS INLET (1) and connect to a FULLY EARTHED OUTLET 4.Connect the synchro cord to the socket (6). 5.Using the mains SWITCH (3) and switch the unit ON ("I" position). 6.Select the power with the touch pad (11-12) 12 11 1 6 3 handle A/ locking ring B/ protective cover (26124) C/ tilthead with locking umbrella holder 5

Control Panel 13 14 15 18 7 12 11 4 2 9 10 8 5 6 3 16 1 21 19 17 20 Overview of controls 1.Mains inlet socket 2.Mains fuse (slow blow) 3.Mains Illuminated on/off switch 4.Modelling fuse (fast blow) 5.Open-flash 6.Synchro-sockets, Amphenol + jack 3.5 mm 7.Digital power display and charge/discharge indicator 8. Acoustic recharging signal (Beep) 9. Slave cell switch on/off 10. Photocell receptor 11. Power adjustment in 1/10 f-stops, with ADF 12. + Power adjustment in 1/10 f-stops 13. Modelling lamp switch (on/off free or prop) 14.+ Modelling power control 15. - Modelling power control 16. Tilt head clamp 17. Knurled clamp screw 18. Handle 19. Stand 5/8-inch socket 20. Umbrella tube (only for EL umbrellas, diameter 7 mm) 21.Supplementary locking for others umbrellas 6

Mains Supply With the MAINS SWITCH (3) switched off ("O" position), firmly push in the plug of the original ELINCHROM mains cord into the mains socket (1). Mains Switch The switch should light up when the compact is switched on ("I" position). (Switch off before removing the mains cord). Troubleshooting If the on/off switch (3) is ON ("I" position) but not illuminated, switch off the unit and check the mains fuse (2). If failed replace with the correct fuse and switch ON the unit. This unit is protected by a thermal circuit breaker to avoid overheating. Should this occur, the unit turns off automatically and cannot be fired. After a break for cooling, the flash will be ready again for operation. See page 11 Troubleshooting This equipment is not user serviceable and contains high voltages which are dangerous. In the event of failure, please return the unit to an authorized Elinchrom service station. Mains Fuse Standard type 5 x 20 mm, (use only tempered fuse) 8 AT (code 19022) for Style 100FX and Style 400FX Note Before exchanging a blown fuse, switch off the unit and remove mains cable. Depress and turn the fuse holder anti-clockwise 1/8th, turn and remove it. If the new fuse blows immediately upon reconnection, return the unit to an ELINCHROM service centre for a check-up. (Please don't forget to check the correct rating of the fuse!). Fuse for modelling light Fast type 5 x 20mm, 4 AF Switch off the unit and replace the blown fuse with a new one of the correct rating. The fastblow fuse will protect the triac of the modelling lamp circuit, the lamp and therefore the flash tube. Mains fuse (Only tempered) 2 Mains socket 1 Modelling fuse 4 3 Mains switch 7

Modelling Light The touch pad (14) controls the modelling lamp on/off and the proportional light. Select the power with the touch pad (15). The modelling light output (100%) is achieved when the power value is set to maximum. Proportional modelling lamp, is set when the position "PROP" is selected (led is illuminated), the light output is proportional to the selected flash power. For all types of Style FX compact flash units, use maximum 200-250W modelling lamps Modelling lamps and fuse (230V Version) Unit Modelling lamp Code Socket Fuse Code Style 100FX 100W krypton 23002 E27 2.5AF 19033 Style 400FX 100W krypton 23002 E27 2.5AF 19033 Option 150W halostar 23035 E27 2.5AF 19033 Option 200W halogen 23034 GX 6,35 2.5AF 19033 Note lamp socket adapter E27 to GX 6.35, code 23101 This adaptator allows the use of the halogen lamp 200W, GX 6.35 (code 23034) in the Style 100 FX and 400 FX units. 230V Modelling lamp options 23033 23101 23035 If the modelling lamp does not illuminate, this may be due to the following 1. The filament is broken after long use *(replace lamp and fuse) 2. The filament is broken after shock *(replace lamp and fuse) 3. An internal component failure, *(return the unit to customer service) * Action required 14 15 15 On/Off proportional Increase Decrease 8

Digital power display The actual flash power is shown in a f-stop compatible format. The power range is 5 f-stops. The digital display, provides continuous power indication of the flash and modelling lamp. The controls cover a continuous output range from full power 1/1 to 1/16th in 1/10th, f-stop intervals. During charging or discharging, the display "flashes". Note The "Style 100 FX and 400 FX" units have an integrated discharge system, protected by a thermic switch. To avoid overheating, lower power settings of more than 2f-stop, can be discharged manually by releasing the flash with the «Test» touch button. Photocell The photocell is actived when the green LED (on the touch pad 9) is illuminated. When switched ON, the unit can be remotely triggered by another flash unit! The Style FX photocell is specially designed to work under ambiant light conditions in your studio. Direct light or other strong light sources may reduce the sensitivity of the cell. In difficult situations e.g. blinding, sunlight or obstacles, the additional cell with 5 m cord (extensions available) solves most problems. Power display 9 Cell 10 Photocell receptor Modellling light controls 5 Test and ready 9

Cordless flash control EL-Skyport triggers flashes without sync cords over a distance of approximately 100 m. Further detailed information please find under www.elinchrom.com / Products / RX Multi Remote EL-Skyport Universal Set (19360) Universal receiver Transmitter Sychronisation socket The standard socket 3.5 mm mini-jack (6). N.B. Do not link ELINCHROM units by cable to other manufacturers sync outlets. ELINCHROM uses the low voltage (5V) for security reasons. Open flash "Test" Test and Ready Having pressed the touch pad to release a flash, the green «READY» light will appear again once the unit is recharged. If the green light does not appear the charge system could be defective. Please contact and send to an authorized Elinchrom service. Beep Audible recharge signal Select the function with the touch pad (8), the green indicator appears. Once recycled an acoustic signal indicates that the compact unit is ready. 5 8 10

Troubleshooting 1. The mains switch (3) is ON ("I" position), but does not light up Switch OFF the unit and change the mains fuse (2) Use only time-lag fuse (16 AT), corresponding to the Style FX model 2. The switch (3) is lit, the open flash ready is lighting up but does not function. The flashtube in the flashhead may be faulty You cannot change the flashtube by yourself! => please return the unit to an authorised Elinchrom service. 3. The ON/OFF switch (3) is lit but the open flash signal (6) is not lit Temporary break for overheating, caused by fast flash sequences or ventilation slots obturated Fan cooling defective => the unit turns off automatically and cannot be fired any more. After a break for cooling, the flash is ready again for operation. If after several minutes of break for cooling the ready signal (6) is not lit, the cause could be a component failure. However, high voltage may remain on the capacitor circuits. => DO NOT ATTEMPT TO REPAIR THE UNIT. In this case please send the unit to an authorised Elincrom station. Training with Elinchrom lighting The Beginner s Guide To Light / 72404 Only in English available. Your DVD Guide to better pictures, show how easy studio photography can be. Learn about flash units and why studio flash is just the better light source for portrait and universal photography. Setting up and controlling flash lights and how to use umbrellas, softboxes, snoots and grids. Have a look and enjoy the passion of photography. Presented by Chris Burfoot. 11

Features Mains switch Controls for modelling on/off, cell on/off, acoustic signal on/off. Flash and modelling power control. «X» synchro jack socket 3,5 mm. Socket for Plug-In remote control. Mains inlet socket and two fuses (Mains and modelling). Locking bayonet ring for accessory and reflector fitting Tilthead whit 5/8" - inch stand socket Thermal safety Halogen modelling lamp 100W, with E27 fitting, or optional alternative *200W/GX6.35 with adaptator code 23101. Silent fan cooling Auto dumping function. Automatic discharge of flash power Central umbrella tube plus external fitting Acoustic recharging signal Mains cable Synchro cord of 5m (jack 3.5mm plug) Protective cover Total compatibility with all Elinchrom accessories Very fast recycling time Very short flash duration Technical data 100FX 400FX Flash power J(Ws) 100 400 Power supply V 200/260 200/260 F-stop, 1m, 100 ISO, with reflector 48 32,5 64,5 Control range J(Ws) 6.25-100 25-400 Recycling time (230 V) s 0,2-0,5 0,3-1,2 Flash duration (t 0,5) 1/1 s 1/1800 1/900 (t 0,5) 1/16 s 1/1150 1/550 Modelling output W 100 100 Voltage across sync cable V 5 5 Connected load A/VA (W) 6.3/1638 6.3/1638 Radio interference suppressiv CE-IEC 491 Dimension length x diam. cm 21x14 21x14 Weight kg 1,55 1,9 Tolerances and specifications conforming to IEC and CE standards. Technical data subject to change without notice. 12

EL Octa 190 cm 26158 EL Quadra 145 x 145 cm 26156 EL Recta 72 x 175 cm 26154 EL Strip 33 x 175 cm 26160 Stand / Umbrella Set To Go 20564 2 stands, 85-235 cm 2 Umbrellas (silver + translucent) & Carrying bag Stand Set A 30160 2 stands, 85-235 cm & Carrying bag Stand Set A 30161 3 stands, 85-235 cm & Carrying bag Elinchrom Case For 3 compacts 33209 For Digital RX & Ranger RX 33215 Elinchrom Softbag For 2 compacts, excepted Style RX 1200 33197 EL Multi-Table Complete 19228 Additional tray 19226 Polystand 31045 Colour Gels 21 cm 26243 Rotalux Square 70 x 70 cm 26178 Rotalux Square 100 x 100 cm 26179 Rotalux Recta 70 x 90 cm 26175 Rotalux Recta 90 x 110 cm 26176 Rotalux Strip 35 x 90 cm 26180 Rotalux Strip 50 x 130 cm 26181 Rotalux Octa 100 cm 26183 Rotalux Octa 135 cm 26184 Rotalux Deep Octa 100 cm 26185 Budget Umbrella Translucent 83 cm 26351 Pro Umbrella Translucent Pro Umbrella Translucent 85 cm 26371 105 cm 26374 Pro Umbrella Silver 105 cm 26361 Pro Umbrella Bronze 105 cm 26379 Pro Umbrella Blue 105 cm 26380 Single units do not include Reflectors - Product range and specifications subject to change. No guarantee for misprints. Barndoor set 21 cm 26037 Polarizing Filter 21 cm 26244 Polarizing Filter 26 cm 26248 Grid 18 cm 30 26100 20 26101 12 26102 Grid 21 cm 30 26052 20 26053 12 26054 8 26055 Barndoor set 26 cm 26040 Budget Umbrella Silver 83 cm 26350 Pro Umbrella White 85 cm 26372 Pro Umbrella White 105 cm 26375 Pro Umbrella Gold 105 cm 26377 Pro Umbrella Silver/Gold 105 cm 26378 Colour Gels 21 cm 26243 Bayonet Reflector Support Set 22061 Deflectors Set Gold-Silver 11.2 cm 26303 Set Gold-Silver 16.5 cm 26304 Translucent 14 cm 26305 Zoom Spot Accessory Set 26484 Snoot Grid set 3 26427 Varistar Set 105 26385 Varistar Set 85 26386 Diffuser Tissu For 70 cm Softlite 26235 For 44 cm Softlite 26232 Each Softlite reflectors incudes a deflector set Grid Reflector 18 cm 60 26144 Standard Reflector 21cm 50 26141 Compact Reflector 21 cm 65 26140 High Perfomance Reflector 26 cm 48 26137 Background Reflector 26165 Varistar Reflector 24 cm 90 26164 Reflector 16 cm 90 26143 Maxi Spot Reflector 40 cm 29 26149 Maxi Lite Reflector 40 cm 43 26147 Softlite White* 70 cm 82 26169 Softlite Silver* 70 cm 64 26167 Softlite Silver* Softlite White* 44 cm 55 26166 44 cm 80 26168 Snoot with Snoot grid 15 26061 Mini Spot Lite with filter holder, lens & Gobos set 26420 Zoom Spot 18-36 26481 Fibre Optic Kit Kit with two glass cables 26430 Kit with one glass cables 26431 Mini S 230V 20106 110V 20105 Mini A Speed 230V 20104 110V 20103 Digital SEE 230V 20172 110V 20173 Digital SE 230V 20174 110V 20175 Digital S 230V 20150 110V 20149 A 3000 N Speed 230V 20168 110V 20167 Twin X4 230V 20180 110V 20181 X 6000 N 230V 20182 110V 20183 Digital RE 230V 20170 110V 20169 Ringflash 3000 230V & 110V 20494 Fresnel Spot SPP 6000 Adapter cable Entry Level Flash Heads Pro Flash Head H.D. Pro Flash Heads Power Flash Heads Effect Lights 11095 EL-Skyport Universal trigger Set 19360 EL-Skyport Computer Remote / Trigger Set 19361 EL-Skyport RX Trigger Set 19362 EL-Skyport RX Trigger Set 19362 EL-Skyport Computer Remote / Trigger Set 19361 Ranger S Head 20100 Ranger A Head 20101 Ringflash 1500 20493 Ranger Snappy 19288 EL-Skyport Universal trigger Set 19360 EL-Skyport Transceiver Adapter 19374 D-Lite 2 20481 D-Lite 4 20482 Multivoltage BX 250 Ri 20460.1 BX 500 Ri 20461.1 Multivoltage Style RX 300 230 V 20625 110 V 20725 Style RX 600 230 V 20626 110 V 20726 Style RX 1200 230 V 20627 110 V 20727 Ranger RX Speed 10265 Ranger RX Speed AS 10267 Ranger RX 10263 Digital RX 2400 230V 10258 110V 10257 Digital RX 1200 230 V 10256 110 V 10255 Digital 1500 AS 230 V 10248 110 V 10247 Digital 3000 AS 230 V 10254 110 V 10253 Classic 3000 230 V 10226 110 V 10225 Entry level Compacts Pro Compacts RX Pro Compacts Battery Power Packs Power Packs 13

GUARANTEE This ELINCHROM product will be repaired free of charge by the vending agent if during a period of 24 months from date of purchase its working order is impaired through a manufacturing or material defect. The faulty product should be immediately sent to the authorized dealer or ELINCA agent. This guarantee is not valid for equipment which has been misused, dismantled, modified or repaired by persons not belonging to the ELINCA distribution network. It does not cover flash tubes, lamps and the normal ageing of capacitors. No responsibilities can be accepted for damage resulting from unsatisfactoıy operation of the equipment, such as wasted film or other expenses. i Please register your Elinchrom product online, under www.elinchrom.com > Downloads > Product Registration In case you cannot register your Elinchrom unit via internet, please fill in the Guarantee card and post it to Elinca. Please return this registratioin card directly to Diese Registrierkarte bitte direkt zurücksenden an Veuillez retourner cette carte d enregistrement directement à Vi preghiamo di far pervenire questa cartolina di iscrizione direttamente a Por favor envie esta carta de registro directamente elinca sa P.O. Box 458 Avenue de Longemalle 11 CH-1020 Renens Switzerland Elinchrom model Elinchrom modèle Elinchrom modell Modello di Elinchrom Modelo de Elinchrom N Date of purchase Datum des Kaufs La date d achat La data di acquisto La fecha de la compra Dealer Händler Négociant Il distributore El comerciante Your full name and address Ihr voller Name und redet an Votre nom complet et adresse Il suo nome pieno ed indirizza Su nombre y apellidos y dirige 14

www.elinchrom.com