Siemens BACnet Programmable TEC Heat Pump Controller Multi-Stage for Smoke Control

Similar documents
FX07 Field Controller

TAC I/NETTM MR-AHU-HP. Application Specific Controller

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Electronic Control Devices The European Product Catalogue 2007

Corp L6 04/09 Supersedes 06/08

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

FX07 Field Controller

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

T5000 T000 LCD Digital Fan Coil Thermostat

BACnet Protocol Implementation Conformance Statement

English plain text messages with constant backlight that brightens during user interaction. On/Off, Floating, or Proportional 0 to 10 VDC Control

SHEET. BASautomation. BAS Router BACnet Multi-Network Router. BAS Router

3466 Building Energy Management Training Systems

Siemens BACnet Programmable TEC Terminal Box (VAV) Controller Owner's Manual

Model: DC-A2IO Advanced HVAC Controller

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

Variable Air Volume - VAV

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Smart Thermostat page 1

PCS0100en Persy Control Services B.V. Netherlands

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Tracer Summit Web Server

Electronic Control Devices The European Product Catalogue 2007

Impact of Control System Technologies on Industrial Energy Savings

HMI display Installation Guide

HERZ-Thermal Actuators

Workshop 7 PC Software - Tracker

IntesisBox KNX Mitsubishi Heavy Industries AC

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Product Catalog BAS-PRC010-E4. Tracker Version 12 Building Automation System. August 2010

UNIFIED FACILITIES GUIDE SPECIFICATIONS

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

ADDENDUM TO THE CONTRACT. for the. Bartlett Regional Hospital Server Room Cooling System Replacement. Contract No. E12-149

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

SECTION DETECTION AND ALARM

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

BACnet. bcx1 Controller/ Router Series


Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

BACnet protocol implementation conformance statement. Corrigo

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

Temperature & Humidity SMS Alert Controller

Adjustable room thermostat for heating only or cooling only systems

HVAC and Lighting Control Products for Open Building Automation Systems

NC-12 Modbus Application

HCE80/HCC80/HCE80R/HCC80R

Portable BACnet /IP to MS/TP Router

Duct Humidity Transmitter

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

PD 100A. Printing data system

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Fire Pump Controllers Remote Alarm Panels

KNX Panasonic Air Conditioners

IntesisBox KNX Modbus RTU master

Mixing Valves. ARGUS Application Note: Mixing Valves

Bring the fresh in. Dedicated Outside Air Systems

Heating Controller. Building Technologies HVAC Products

Protects against unwanted thermostat controller tampering. Increases occupancy comfort by providing dehumidification.

STAT-RT Series.

OZW30. Central Unit SYNERGYR

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

T7079A,B Solid State Remote Temperature Controllers

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

SiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc.

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

Remote Monitoring and REC 501 Control Unit Product Guide

TAC I/NETTM. Process Control Unit

IntesisBox Modbus Server SAMSUNG Air Conditioners

BACnet Automation Interface Module (Network Version)

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

Chassis, Power Supply, and Element Management

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Controls for fan coil units and cassettes

TC-9102 Series Surface Mount Temperature Controllers

Modbus Server SAMSUNG Air Conditioners

SECTION LOW VOLTAGE LIGHTING CONTROLS

Sterowniki uniwersalne z serii IR32. This is a universal step control for low cost solutions

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

Electric Rotary Actuator - On/Off or programmable control actuator

THERMAL MANAGEMENT SOLUTIONS

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

COMMUNICATION PROTOCOL pag. 1/7. BACnet Protocol Implementation Conformance Statement

Transcription:

Technical Specification Sheet Document No. 149-838 August 12, 2011 Siemens BACnet Programmable TEC Heat Pump Controller Multi-Stage for Smoke Control Setpoints and control parameters stored in Electrically Erasable Programmable Read Only Memory (EEPROM) no battery backup required. Returns from power failure without operator intervention. No calibration required, thereby reducing maintenance costs. provides high performance Direct Digital Control (DDC) technology for room temperature control of heat pumps. The BACnet Heat Pump Controller and related components provide a completely electronic control system. can operate stand-alone or can be networked to perform complex HVAC control, monitoring and energy management functions and is designed to reside on any BACnet control system. Features UL864 Listed for Smoke Control Communicates using BACnet MS/TP protocol for open communications on BACnet MS/TP networks. BTL listed as a B-ASC device. Programmable using PPCL. Setpoints and control parameters assigned and changed locally or remotely. PID control of HVAC systems to minimize offset and maintain tighter setpoint control. Unique control algorithms for specific applications. Supports Room Sensor with relative setpoint adjustment. Control capable of modulating floating control electronic or electric damper actuator. Damper status can be reported in either percentage open notation with floating control or in voltage notation with 0-10 Vdc actuators. User-adjustable offset for the room temperature reading when required for validation purposes. Applications Slave Mode (Application 6590) Multiple Compressor Heat Pump with Reversing Valve and Mixed Air Control (Application 6573) Mulitple Heating and Cooling Heat Pump with Mixed Air Control and Internal Reversing Valve (Application 6574) Page 1 of 5

Control algorithms are preprogrammed. The controller is ready to operate after selecting the application. If desired, the operator may adjust the room temperature setpoints and other parameters. The controller is designed for operation and modification without vendor assistance. If required, new custom code using our PPCL programming language can be added to replace or supplement the standard application residing in the controller. This provides the flexibility to meet many job specifications with the assurance of having a proven and tested standard application to rely upon. Hardware consists of an electronic controller assembly. This controller provides all wiring terminations for system and local communication and power. The cable from the room sensor (purchased separately) connects to an RJ-11 jack on the controller. All other connections are removable terminal blocks. The controller assembly is mounted on a plastic track that mounts directly on the heat pump. An optional enclosure (P/N 550-002) protects the controller assembly. The controller interfaces with the following external devices: Floating control or Spring-return damper actuator Temperature sensors (room, mixed air) Service and commissioning tools Digital input devices (dry contacts from motion sensors, alarm contacts, switches) Digital output devices (fan, reversing valve, single or two-stage compressor, single-stage or auxiliary heat) UL864 Listed for Smoke Control The BACnet PTEC hardware has passed stringent electrical and thermal tests that ensure increased product reliability and performance as a part of a Siemens engineered smoke control system. The BACnet PTEC is used to control the operation of the fans and dampers based on the smoke control strategy being initiated in the supervisory controller. Room Sensor The room sensor connection to the controller board consists of a quick-connect RJ-11 jack. This streamlines installation and reduces controller start-up time. Combination Temperature and Relative Humidity Models The Series 2200 range of TEC room units includes combination temperature and humidity models. For these models, both temperature and relative humidity values are passed digitally to the TEC. This information is passed from the room unit through the RJ-11 cable to the RTS port on the TEC. See the Series 2200 Temperature Room Units for TEC and ATEC Technical Specification Sheet (149-820), for more information. Heat Pump Controller Specifications Dimensions Weight Controlled Temperature Accuracy, Heating or Cooling Power Requirements Operating Range Power Consumption Inputs Analog Digital Outputs Analog Digital 4-1/8" W 11-1/4" L 1-1/2" H approx. 3 lbs (1.35 kg) ±1.5 F (0.9 C) 19.2 to 27.6 Vac, 50 or 60 Hz 10 VA (plus 5 VA per DO), 60 VA max 1 room temperature sensor (10k thermistor) 1 setpoint (optional at RTS) 2 auxiliary temperature sensor (10k thermistor) 1 selectable 0-10 Vdc/4-20 ma 2 dry contacts (plus 1 override switch, optional, part of RTS) 3 0-10 Vdc 8 DO 24 Vac optically isolated solid state switches @ 0.5 amp Page 2 of 5

Communications Remote BACnet MS/TP (EIA 485), 9600 bps to 76800 bps FLN Trunk Local Ambient Conditions WCIS and PTEC Tool Document Information Technical Specification Sheets/Technical Instructions Room Temperature Sensors Series 2200 Document Part Number 149-820 Storage Temperature Operating Temperature Humidity Range -40 F to 167 F (-40 C to 75 C) 32 F to 122 F (0 C to 50 C) 0% to 92% (non-condensing) Duct Temperature Sensor 149-134P25 Low Limit Detection Thermostat 155-016P25 Analog Sensors 10 K Ohm Thermistor 149-912, 149-915, and 149-916 Agency Listings UL Listing cul Listed UL 864, UUKL, PAZX Canadian Standards C22.2 No. 205-M1983, PAZX7 FCC Compliance 47 CFR Part 15 Siemens Valves and Electronic Actuators 599 Series Zone Valves 2-Way, 3-Way Zone Valve Electric and Thermic Actuators 599 Series Zone Valves and Actuators Modulating, On/Off Spring Return, 2- Position Control 155-034 155-063 Ordering Information Description Smoke Control Listed Siemens BACnet PTEC Heat Pump Controller, UUKL Large enclosure for electronic controller without damper actuator (long board). UL Listed Class 2 transformer with 120/240/277/480 Vac 50/60 HZ 0.4A primary w/ hub and 24 Vac 50 VA secondary w/ hub and circuit breaker. UL Listed Class 2 transformer with 120/240/277/480 Vac 50/60 HZ 0.5A primary w/ hub and 24 Vac 96 VA secondary w/ hub and circuit breaker. UL Listed Class 2 Transformer with primary 120V 60 HZ 0.2A secondary 24 Vac 30 VA. Part Number 550-490PK 550-002K TR50VA004 TR100VA004 KELE AM-2483- OA Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are introduced. or company names mentioned herein may be the trademarks of their respective owners. 2011 Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 USA +1 847-215-1000 Your feedback is important to us. If you have comments about this document, please send them to SBT_technical.editor.us.sbt@siemens.com. Document No.149-838 Printed in the USA Page 3 of 5

BACnet Protocol Implementation Conformance Statement s Model Number Protocol Software Firmware Smoke Control Listed Siemens BACnet PTEC Heat Pump Controller, UUKL 550-490PK 4 (135-2004) 2.0.5.1 BK43 Date Tested: July 2011 B-ASC Vendor Information Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089 www.buildingtechnologies.siemens.com/bt/us Description The controller is an integral part of Siemens controls system. The controller can operate stand-alone or can be networked to perform complex HVAC control, monitoring, and energy management functions. This controller communicates using BACnet MS/TP. BACnet Standardized Device Profile Device Profile Tested PTEC BACnet Application Specific Controller (B-ASC) Supported BACnet Interoperability Building Block (BIBBs) BIBB Name Tested PTEC DS-RP-B Data Sharing-ReadProperty-B DS-RPM-B Data Sharing-ReadPropertyMultiple-B DS-WP-B Data Sharing-WriteProperty-B DM-DDB-B Device Management-Dynamic Device Binding-B DM-DOB-B Device Management-Dynamic Object Binding-B DM-DDC-B Device Management-DeviceCommunicationControl-B DM-RD-B Device Management-ReinitializeDevice-B DM-BR-B Device Management-Backup and Restore-B DM-OCD-B Device Management-Object Creation and Deletion-B Page 4 of 5

Standard Object Types Supported Object Type Creatable Deletable PTEC Analog Input No No Analog Output Yes Yes Binary Input No No Binary Output Yes Yes Device No No File Yes Yes Program Yes Yes Data Link Layer Options Data Link and Options MS/TP master (Clause 9), baud rate(s): 9600 bps, 19200 bps, 38400 bps, 76800 bps MS/TP slave (Clause 9), baud rate(s): 9600 bps, 19200 bps, 38400 bps, 76800 bps Segmentation Capability Segmentation Type Supported Window Size: 32 (MS/TP product limited to 1) Able to transmit segmented messages No Able to receive segmented messages No Device Address Binding Static Device Binding Supported Yes Networking Options Static Device Binding Supported No Character Sets Charcter Sets Supported ANSI X3.4 Page 5 of 5